Professional Documents
Culture Documents
SIGNATURE:
MIRROR CABINET KBF FOR ECCC
TO DETAIL 75x75 Flashing 150
25
110 200 400 300 300 300 300 300 300 300 275 63 300 300 300 300 250 Angle CONSTRUCTION ISSUE
SIGNATURE:
FALSE CEILING Sealant KBF FOR ECCC
FALSE CEILING
100
100
Wall Tile
+2250 +2250
CFL CFL
SH 6 Thk FC Board COPYRIGHT EAST COAST CONSTRUCTION COMPANY PTY.
100
Ledge Wall
100
LTD.
400
400
141 770 1050 393 393 REPRODUCTION OF THE WHOLE OR PART OF THE
1050
1025
DOCUMENT CONSTITUTES AND INFRINGES COPYRIGHT. THE
SH
1513 Wall Tile INFORMATION, IDEAS AND CONCEPTS CONTAINED IN THIS
780 DOCUMENT ARE CONFIDENTIAL. THE RECIPIENT(S) OF THIS
600
6 Thk FC Board DOCUMENT ARE PROHIBITED FROM DISCLOSING SUCH
Nogging Track
1000
INFORMATION IDEAS AND CONCEPTS TO ANY PERSON
TL 2 Stud Wall WITHOUT PRIOR WRITTEN CONSENT OF THE COPYRIGHT
HOLDER. ECCC HOLDS A LICENSE FROM ARBT IN RESPECT
OF PROPRITARY ITEMS
600
600
2300 SS 75x75 75x75 NOTE THIS DRAWING IS PREPARED BY EAST COAST
Flashing Angle Flashing Angle CONSTRUCTION COMPANY UNDER ITS QBCC LICENCE
TL 3 TL 2
50
TL 2 TL 3 FOR THE USE OF EAST COAST CONSTRUCTION COMPANY
Starken Panel PTY LTD AS THE CONTRACTOR ON THIS PROJECT
TL 3 MX
SUB- CONTRACTORS TO CHECK AND VERIFY ALL LEVELS,
VB
2200
2200
DATUMS & DIMENSIONS ON SITE AND SHALL REPORT ANY
200
200
DISCREPANCIES OR OMISSIONS TO THIS OFFICE PRIOR TO
2030
MX START OF WORK & DURING THE CONSTRUCTION PHASE.
526 526 462 462
200
1800
1800
600
600
STRUCTURAL, MECHANICAL, ELECTRICAL AND OR ANY
1800
393 393 MX OTHER CONSULTANTS DOCUMENTATION AS MAY BE
PH Scale - 1 : 20 APPLICABLE TO THE PROJECT PRIOR TO STARTING &
DURATION OF THE WORKS.
TL 2 75x75
1200
1200
150 Flashing Angle
1200
25
1050
1000
1000
850
Sealant
720
600
600
WC
585
MX
SET OUT HEIGHT SET OUT HEIGHT
BASED ON TL 2 400 BASED ON TL 1
LONGEST VALLEY LONGEST VALLEY 6 Thk G 13-06-20 DS BB SLOPE RATIO REVISED
50
E 16-12-19 JN BB REVISED AS PER COMMENTS
50
1200
1175
3100 1513 D 14-12-19 JN BB REVISED AS PER COMMENTS
50
FALSE CEILING
100
100
FALSE CEILING
+2250 +2250
ASIA PACIFIC
CFL CFL 150 Starken Panel
80
400
400
780 LEDGE WALL DETAIL @ SHOWER DESIGN & CONSTRUCTION:
Scale - 1 : 20
MIRROR CABINET
TO DETAIL
900
1150
Motor bed Main drainage flow
600
600
EAST COAST CONSTRUCTION COMPANY PTY LTD
TL 2 E-mail: admin@ecccgroup.com.au
TL 2 Floor tiles Path of moisture Telephone: +61 (448)904475
through grout and
SS 2300 613 mortar DETAIL AND DRAFTING:
TL 3
2200
2200
MX
2120
D-02 Grout
VB
Waterproof
200
1800
Drainage flange
600
600
membrane
1800
1200
1050
1050
Scale - 1 : 10 PROPOSED RESIDENTIAL AT PLOT-50&
850
54,CARL STREET,
720
WOOLOONGABBA,QLD,AUSTRALIA
600
600
SET OUT HEIGHT TL 1 SET OUT HEIGHT TL 1
BASED ON BASED ON
LONGEST VALLEY LONGEST VALLEY DRAWING TITLE:
SLOPE 1:70
+50.0
FFL
SLOPE 1:90 SLOPE 1:90 +50.0
FFL
SLOPE 1:90
LEVEL 1 TO 4
TOILET ELEVATIONS
50
50
CARL_SANITARY LEGEND
6/18/2020 12:03:12 PM
780 2300 900 473 140
20 3100 1513
(TYPE 03)
NOTE: CODE DESCRIPTION DRAWN: CHECKED:
MX MIXER TAP JN BB
ELEVATION - E3 ELEVATION - E4 CARL_FINISH LEGEND PH PAPER HOLDER
FIRST ISSUE: SCALE:
Scale - 1 : 25 Scale - 1 : 25 CODE DESCRIPTION SH SHOWER HEAD 03-10-2019 As indicated @ A3
Waterproofing As Per - AS3740 TL 1 150 X 150mm (FLOOR TILE) SS SHOWER SCREEN FIXING AT SITE PROJECT NO DRAWING NO REVISION
TL 2 300 X 600mm (WALL TILE) VB VANITY BASIN
TL 3 LEDGE WALL TOP FINISH (TO BE CONFIRM) WC WATER CLOSET 1802 A 422-1 G