You are on page 1of 1

APPROVAL ISSUE

SIGNATURE:
MIRROR CABINET KBF FOR ECCC
TO DETAIL 75x75 Flashing 150

25
110 200 400 300 300 300 300 300 300 300 275 63 300 300 300 300 250 Angle CONSTRUCTION ISSUE

SIGNATURE:
FALSE CEILING Sealant KBF FOR ECCC
FALSE CEILING

100
100

Wall Tile
+2250 +2250
CFL CFL
SH 6 Thk FC Board COPYRIGHT EAST COAST CONSTRUCTION COMPANY PTY.

100
Ledge Wall

100
LTD.
400

400
141 770 1050 393 393 REPRODUCTION OF THE WHOLE OR PART OF THE

1050
1025
DOCUMENT CONSTITUTES AND INFRINGES COPYRIGHT. THE
SH
1513 Wall Tile INFORMATION, IDEAS AND CONCEPTS CONTAINED IN THIS
780 DOCUMENT ARE CONFIDENTIAL. THE RECIPIENT(S) OF THIS

600
6 Thk FC Board DOCUMENT ARE PROHIBITED FROM DISCLOSING SUCH
Nogging Track

1000
INFORMATION IDEAS AND CONCEPTS TO ANY PERSON
TL 2 Stud Wall WITHOUT PRIOR WRITTEN CONSENT OF THE COPYRIGHT
HOLDER. ECCC HOLDS A LICENSE FROM ARBT IN RESPECT
OF PROPRITARY ITEMS
600

600
2300 SS 75x75 75x75 NOTE THIS DRAWING IS PREPARED BY EAST COAST
Flashing Angle Flashing Angle CONSTRUCTION COMPANY UNDER ITS QBCC LICENCE
TL 3 TL 2

50
TL 2 TL 3 FOR THE USE OF EAST COAST CONSTRUCTION COMPANY
Starken Panel PTY LTD AS THE CONTRACTOR ON THIS PROJECT
TL 3 MX
SUB- CONTRACTORS TO CHECK AND VERIFY ALL LEVELS,
VB
2200

2200
DATUMS & DIMENSIONS ON SITE AND SHALL REPORT ANY

200

200
DISCREPANCIES OR OMISSIONS TO THIS OFFICE PRIOR TO

2030
MX START OF WORK & DURING THE CONSTRUCTION PHASE.
526 526 462 462
200

THE DRAWING ARE TO BE READ IN CONJUNCTION WITH


LEDGE WALL DETAIL @ BASIN

1800
1800
600

600
STRUCTURAL, MECHANICAL, ELECTRICAL AND OR ANY

1800
393 393 MX OTHER CONSULTANTS DOCUMENTATION AS MAY BE
PH Scale - 1 : 20 APPLICABLE TO THE PROJECT PRIOR TO STARTING &
DURATION OF THE WORKS.

TL 2 75x75

1200

1200
150 Flashing Angle
1200

25
1050

1000

1000
850

Sealant
720
600

600
WC
585

MX
SET OUT HEIGHT SET OUT HEIGHT
BASED ON TL 2 400 BASED ON TL 1
LONGEST VALLEY LONGEST VALLEY 6 Thk G 13-06-20 DS BB SLOPE RATIO REVISED

SLOPE 1:90 SLOPE 1:70 SLOPE 1:70 FC Board


+50.0 +50.0 F 06-02-20 JN BB LEDGE WALL - REVISED
FFL FFL
Ledge Wall

50
E 16-12-19 JN BB REVISED AS PER COMMENTS
50

325 1051 924 20 780 150 1363

1200
1175
3100 1513 D 14-12-19 JN BB REVISED AS PER COMMENTS

REFER DETAIL A REFER DETAIL A Wall Tile Wall Tile


C 23-10-19 JN BB SHOWER CUBICLE REVISED
REFER DETAIL A
ELEVATION - E1 ELEVATION - E2
6 Thk FC Board B 04-10-19 JN BB MIRROR CABINET REVISED
Scale - 1 : 25 Scale - 1 : 25
Stud Wall A 03-10-19 JN BB PRILIMINARY ISSUE
Nogging Track
275 300 300 300 300 300 300 300 300 300 110 125 300 300 174 251 300 63 REV DATE DRN CHK DESCRIPTION
75x75 25 75x75
Flashing Angle Flashing Angle CLIENT:

50
FALSE CEILING

100
100

FALSE CEILING
+2250 +2250
ASIA PACIFIC
CFL CFL 150 Starken Panel

80
400

400
780 LEDGE WALL DETAIL @ SHOWER DESIGN & CONSTRUCTION:
Scale - 1 : 20
MIRROR CABINET
TO DETAIL

900

1150
Motor bed Main drainage flow
600

600
EAST COAST CONSTRUCTION COMPANY PTY LTD
TL 2 E-mail: admin@ecccgroup.com.au
TL 2 Floor tiles Path of moisture Telephone: +61 (448)904475
through grout and
SS 2300 613 mortar DETAIL AND DRAFTING:
TL 3
2200

2200

MX
2120
D-02 Grout
VB
Waterproof

200
1800

Drainage flange
600

600
membrane
1800

Bradman Technologies Private Limited


31/22,Victoria Cresent Rd.Egmore,Chennai - 8,India
TEL: +91 44 42043347 Email: info@bradmanit.com

DETAIL - A (PADDLE FLANGE) PROJECT:


1200

1200

1050

1050
Scale - 1 : 10 PROPOSED RESIDENTIAL AT PLOT-50&

850
54,CARL STREET,

720
WOOLOONGABBA,QLD,AUSTRALIA
600

600
SET OUT HEIGHT TL 1 SET OUT HEIGHT TL 1
BASED ON BASED ON
LONGEST VALLEY LONGEST VALLEY DRAWING TITLE:
SLOPE 1:70
+50.0
FFL
SLOPE 1:90 SLOPE 1:90 +50.0
FFL
SLOPE 1:90
LEVEL 1 TO 4
TOILET ELEVATIONS
50
50

CARL_SANITARY LEGEND

6/18/2020 12:03:12 PM
780 2300 900 473 140
20 3100 1513
(TYPE 03)
NOTE: CODE DESCRIPTION DRAWN: CHECKED:
MX MIXER TAP JN BB
ELEVATION - E3 ELEVATION - E4 CARL_FINISH LEGEND PH PAPER HOLDER
FIRST ISSUE: SCALE:
Scale - 1 : 25 Scale - 1 : 25 CODE DESCRIPTION SH SHOWER HEAD 03-10-2019 As indicated @ A3
Waterproofing As Per - AS3740 TL 1 150 X 150mm (FLOOR TILE) SS SHOWER SCREEN FIXING AT SITE PROJECT NO DRAWING NO REVISION
TL 2 300 X 600mm (WALL TILE) VB VANITY BASIN
TL 3 LEDGE WALL TOP FINISH (TO BE CONFIRM) WC WATER CLOSET 1802 A 422-1 G