You are on page 1of 8

Eaton’s enclosed meter family

Single- and multi-unit


enclosed meters
Enclosed meters
The Eaton enclosed meter line provides a complete energy
metering and data acquisition solution in a single enclosure.
Designed for Eaton’s IQ 35M, IQ 150, IQ 250/260, and Power Xpert®
2000/4000/6000/8000 and Multi-Point Meters, Eaton’s enclosed
meter line offers mounting and installation flexibility, especially
in retrofit applications where no metering compartment or mounting
space is available in the existing electrical distribution equipment or
where installation time is a premium. Factory designed and wired,
Eaton’s enclosed meter line offers savings in labor and installation
costs because input current and voltage wiring as well as I/O wiring
is prewired to terminal blocks inside the enclosure.
The enclosed meter line has points, collect and log specific
two standard offerings: single-, energy use parameters, and
prewired unit (specific IQ 150, display and generate logs for
IQ 250/260, PXM 2000, PXM historical energy usage reports.
4000/6000/8000 and PXBCM or Simply put, Eaton’s multi-unit
PXMP) and a multi-unit (specific enclosed meter solution helps
IQ 150, IQ 250/260 or IQ 35M meet any measurement and
models). Because the multi-unit verification requirement to show
can include Eaton’s Power energy efficiency improvements
Xpert Gateway 900, it facilitates and results. In addition to the
measurement and verification of standard offering, Eaton can also
the energy usage on processes provide an enclosed metering
and in buildings. This provides solution tailored around your
a convenient way to monitor project needs.
energy usage from multiple

Multi-unit Single-unit Power Xpert Multi-Point/Power Power Xpert Meter


NEMAT 12 (front view) NEMA 12 (front view) Xpert Branch Circuit Monitor 4000/6000/8000
NEMA 12 (front view) NEMA 12 (front view)

2 EATON Eaton's enclosed meter family


Applications Factory wired
Factory designed and wired to fit various Eaton power and energy Most electrical contractors are very familiar with wiring meters.
meters at varying price points, Eaton’s enclosed meter line offers However, it does take time to place the disconnect, the CT shorting
savings in labor and installation costs because input current and blocks, the terminal blocks, the control power transformer and
voltage wiring, as well as I/O wiring, is prewired to terminal blocks so on, and the associated wiring. It is not uncommon for errors
inside the enclosure. Standalone, enclosed meters are ideal for new to be introduced during the installation of multiple meters; it’s just
metering applications where no metering existed previously, for inherent in wiring. With Eaton’s enclosed meter line, everything is
retrofit installations where energy monitoring is a must or where wired at the factory—the shorting block, the terminal blocks and
ease of installation is required. so on—assuring that it’s done right. Further, to ensure safety,
Eaton’s enclosed meter line includes a primary fusible disconnect
• Health care facilities
for line voltage, which can be turned off during meter maintenance.
• Educational facilities and campuses
For applications with line voltages above the rated power supply
• Industrial facilities of the meter, an optional control power transformer is supplied in
the enclosure. Control voltage can also be supplied via a separate
• Commercial facilities source that is wired to the field installation terminal block. CT inputs
• Government facilities for the meter are wired directly to the shorting terminal blocks for
easy field installation.
The multi-unit offering consolidates energy-related data available Factory-wired products also save on installation time and costs.
from the meters in the enclosure, but also allows for external The meters are flush mounted on the enclosure door with all
meters to be added to the embedded Power Xpert Gateway 900. inputs/outputs factory wired to the terminal blocks.
Through the Power Xpert Gateway 900’s embedded Web server,
A meter subpanel assembly is also available, which includes all
information can be presented in a variety of ways; a standard
the internal components of the single-unit enclosed meter for
Web browser being the most widely used method.
the IQ 150/250/260 and PXM 2000 Meters wired and mounted
The enclosed product is a standalone solution that is ideal for on a subpanel to be installed into an existing electrical structure.
many infrastructure designs. Further, as needs change and grow, It comes with a 48-inch lead for flexibility in mounting the meters
the enclosed product can be integrated through PXI or ForeseerT at various distances.
Software into a broader solution that encompasses other intelligent
hardware and can integrate with third-party network management
systems (NMS) or building management systems (BMS) for
system-wide monitoring and reporting of energy and power.

Features/benefits
• Saves installation time and cost
• One part number to order; no need to worry that any part
has been left out
• Pick the meter or meters you need as it is designed to fit
various Eaton power and energy meters, at varying price points

EATON Eaton's enclosed meter family 3


NEMA rated
NEMA 12 enclosure prevents NEMA 3R enclosure is NEMA 4X enclosure provides
dust and other materials constructed for either indoor the same degree of protection
from entering the equipment. or outdoor use. It helps to as the NEMA 3R with the
Internal gaskets also prevent air protect personnel from access additional protection against
irritants from harming the vital to hazardous parts and provides windblown dust, splashing
equipment inside. This quality a degree of protection for and hose-directed water,
enclosure meets most indoor equipment inside the enclosure and corrosion.
application needs. against ingress of solid foreign
objects (falling dirt), harmful
effects of water (rain, sleet,
snow) and external formation
of ice on the enclosure.

Gateway
power supply
Fused
disconnect
Fused
disconnect
Neutral,
Meter fusing
ground and
input/output
(not shown) PXG900 Gateway
Control power,
Control terminal voltage, CT and
power, blocks Fused control
communications power
voltage inputs
and CT CT shorting transformer
inputs terminal block
Ground

Prewired CT shorting
control blocks
power
Meter fusing transformer

NEMA 12 front view, door open, prewired and tested NEMA 12 multi-unit view, door open, prewired and tested

Fused Meter
disconnect fusing

Prewired
control
power
transformer

Display
Meter
control
power,
voltage
and CT
inputs

CT shorting terminal blocks


NEMA 12 single-unit enclosed meter inside view, NEMA 3R single-unit closed and open, IQ 150/250/260
PXM 4000/6000/8000 series and PXM 2000 series

4 EATON Eaton's enclosed meter family


Meter
fusing

Fused
disconnect

Gateway power
supply

Optional
6-inch PXG900 Gateway
color touch MME Module -
screen 25 CT Inputs

Display Control power,


power voltage current
supply sensor and
communications
inputs

Meter base

Current sensor
terminal strip

Enclosed Power Xpert Branch Circuit Monitor Multi-unit enclosed meter, inside view of IQ 35M

48-inch meter Fused Fuses PXMP


harness disconnect power
supply

PXMP
meter
6-inch color base
Meter connections
touchscreen
fusing
Fused
disconnect

PXMP meter base

PXMP meter modules


(not shown—sold separately)

Optional CT shorting NEMA 12 enclosure


CPT block (30 H x 24 W x 12 D inches)

Prewired meter backpan, single unit Enclosed Power Xpert Multi-Point Meter

• Prewired panel to save installation time and cost for retrofits


into existing equipment
• Designed for Eaton’s:
• IQ 100 Meter series
• IQ 250/260
• Power Xpert Meter 2000 series
• With or without CPT, depending on voltage
• Order meters separately

EATON Eaton's enclosed meter family 5


Enclosed meter product specifications Ordering information
Description Specification
Single-unit enclosed meter
Enclosure rating NEMA 12, 3R, 4X
Enclosure operating –20 °C to +40 °C
temperature Note: Temperature range of meter is –20 °C to +70 °C. PXM2250MA65105 - 2 B
If applied outside, proper precautions should be taken to
avoid exceeding the maximum and minimum temperature
ratings of the meter. Meter type CPT option
Dimensions Single unit (IQ 150/250/260 and PXM 2000): PXM4051A1BA PXM2270MA65105 A = 120/240 Vac (no CPT)
NEMA 12 (8.00 W x 16.30 H x 10.40 D inches), PXM4051A1BB PXM2270MA65115 B = 480 Vac (control
NEMA 3R/4X (8.00 W x 16.30 H x 9.60 D inches) PXM6051A1BA PXM2270MA65145 power transformer)
Single MME (PXBCM) PXM6051A1BB IQ250MA65100
NEMA 12 (16.00 W x 16.00 H x 8.00 D inches) PXM8051A1BA IQ250MA65110 NEMA rating
NEMA 3R/4X (20.00 W x 16.00 H x 12.00 D inches) PXM8051A1BB IQ250MA65114
Two MME (PXBCM) 2 = NEMA 12
PXM2250MA65105 IQ260MA65100
NEMA 12 (16.00 W x 24.00 H x 8.00 D inches) 3 = NEMA 3R
PXM2250MA65115 IQ260MA65110
NEMA 3R/4X (20.00 W x 24.00 H x 12.00 D inches) 4 = NEMA 4X
PXM2250MA65145 IQ260MA65114
Single unit (PXMP): PXM2260MA65105 IQ150MA6511
NEMA 12/3R/4X (24.00 W x 30.00 H x 12.00 D inches) PXM2260MA65115 IQ150MA6512
Single unit (PXM 4000/6000/8000): PXM2260MA65145
NEMA 12 (20.00 W x 24.00 H x 14.10 D inches)
NEMA 3R/4X (20.20 W x 24.00 H x 13.90 D inches)
Multi unit:
NEMA 12 (13.00 W x 30.00 H x 15.20 D inches) Enclosed PXMP meter
NEMA 3R (13.20 W x 30.10 H x 14.60 D inches)
NEMA 4X (13.00 W x 30.00 H x 14.00 D inches)
PXMP-MB - 2 B - D
Meters Single unit: IQ 150, IQ 250/260, PXM 2000/4000/6000/8000
and PXMP models
Multi unit: IQ 35M, IQ 150 and IQ 250/260 Meter type NEMA rating Display
Communications Power Xpert Gateway 900 PXMP-MB 2 = NEMA 12 Power supply A = None
(multi unit only) PXMP-MB-AB 3 = NEMA 3R A = None D = 6-inch color
Control voltage 120–600 V (PXMP)—power supply required 4 = NEMA 4X B = 120/240 Vac touchscreen
100–277 Vac L:N (PXBCM)—no CPT required C = 480 Vac
Up to 240 V (IQ 35M/150/250/260 and D = 600 Vac
PXM 2000/4000/6000/8000)—no CPT required
Greater than 240 V (IQ 150/250/260 and PXM 2000)—
CPT required Power Xpert Branch Circuit Monitor enclosed meter
Separate source control—no CPT required
Basic model Fusible disconnect—primary voltage PXBCM-MB - 2 1 - A B
Shorting block(s)—not required for IQ 35M or PXMP
Ground terminal block
Neutral terminal block
Eight-point terminal block(s) for input/output Meter type
modules for IQ 250/260 and PXM 2000 PXBCM-MB MME input Display
Wiring Wired for three-phase, four-wire applications. Three-phase, (Meter base + MME) modules A = None
three-wire applications—will need to change the wiring PXBCM-MME 1 = 1 MME D = 6-inch color
for both the voltage and the current per the wiring diagram (MME only— (21 branch touchscreen
in the meter instruction manual. CT inputs,
no display)
Certifications UL® 508A and cUL® 4 aux. inputs) Display power supply
Source control No separate source control voltage required for applica- NEMA rating 2 = 2 MME
A = 120–240 V
tions below 240 Vac (except PXMP) (42 branch
2 = NEMA 12 B = 480 V
CT inputs,
Prewired Prewired current transformer, shorting terminal block(s), 3 = NEMA 3R
neutral, ground, voltage, control power, fusible disconnect 8 aux. inputs)
4 = NEMA 4X
and input/output terminal block(s)
Latch Padlocking latch provision
Optional features Control power transformer—single unit: 50 VA
(IQ 150/250/260) and 150 VA (PXM 4000/6000/8000); Multi-unit enclosed meter
multi unit: 250 VA control power supply for meter where
monitored voltage is 480 Vac (IQ 150/250/260 and PXM IQ150MA6511 - 2 B 4 C
2000/4000/6000/8000)
NNote: Specifications are subject to change without notice and represent the
maximum capabilities of the product with all options installed. This is not Meter type Communications
a complete feature list. Features and functionality may vary depending on
selected options, firmware version and product model. Please refer to the IQ35MA12 C = Includes
IQ150MA6511 CPT option PXG 900
technical data sheet and the user manual for detailed specifications.
IQ250MA65100 A = 120/240 Vac
IQ260MA65100 (no CPT) Number of meters
B = 480 Vac 
Meter subpanel assembly 4 = 4 meters
NEMA rating (control power
Description Catalog Number transformer)
2 = NEMA 12 
Meter subpanel assembly for PXM 2000 PXM2K-MSPA-A 3 = NEMA 3R
and IQ 150/250/260 Meters 4 = NEMA 4X
Meter subpanel assembly with CPT for PXM 2000 and IQ PXM2K-MSPA-B
150/250/260 Meters A Not available with IQ 35M.

NNote: Other meter models available upon request in single- and multi-unit
enclosed versions.

6 EATON Eaton's enclosed meter family


FACTORY WIRED
With Eaton’s enclosed meter line,
everything is wired at the factory—
the shorting block, the terminal
blocks and so on—assuring that it’s
done right. Further, to ensure safety,
Eaton’s enclosed meter line includes
a primary fusible disconnect for line
voltage, which can be turned off
during meter maintenance.

EATON Eaton's enclosed meter family 7


Flex Center
Eaton’s Meter Flex Center
can provide above and Lifting rings
beyond the standard meter
enclosure offerings. The Single-pole touchsafe
Meter Flex Center can tailor PXM 2000
power meters fuse block
the enclosed solution to meet
the specification requirements. CT shorting
Special requirements within the blocks
enclosures can be size, number
of meters, differing meter
models, special communication Fuses
equipment, uninterruptible Removable
power supplies, electric heaters, covers for
power receptacles, or any future meters
Grounding
other custom need. Here is an bar
example of just a few of the
Meter Flex Center capabilities.
ELC-PS02
24 Vdc
Communications power supply
connections for
other meters Single-pole
touchsafe
PXG900 fuse holder
Communications Switch for
Gateway PXM 2000
Control power Incoming
transformer line circuit
protector
Duplex
receptacle
NEMA 1 16 meter enclosure with PXM 2000 front view and door open

To find out more about how Eaton’s enclosed


meter family can you help you manage your energy
use, go to Eaton.com/meters or contact Eaton at
1-877-ETN-CARE or pqsupport@eaton.com.

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

© 2015 Eaton Follow us on social media to get the


All Rights Reserved Eaton is a registered trademark. latest product and support information.
Printed in USA
Publication No. BR026002EN / Z17503 All other trademarks are property
November 2015 of their respective owners.

You might also like