CNC Control S4000
PRINCIPAL CHARACTERISTICS OF CONTROL
HW Characteristics
DIGITAL I/O
ANALOG I/O
SYEL srl Via Liguria, 1- 56030 Pontedera Gello (PI) Tel. ++39 0587 294096 e-mail: syel@syel.it web: www.syel.it
CNC Control S4000
J, K, various types of analog transducers, pressure, current, volt, ecc…
PROGRAMMING Proteus
C Language and Ladder
Debugger on-line for C language and
For Ladder language also remotato
with Internet
SYEL srl Via Liguria, 1- 56030 Pontedera Gello (PI) Tel. ++39 0587 294096 e-mail: syel@syel.it web: www.syel.it
Seriale Seriale Fibra Ottica
Analog Outputs Encoder Inputs CAN e RS232 RS485 uscita audio Ethernet Ingressi analogici
DOWN G R2 G R1 Z2- Z2+ B2- A2- 12V B2+ A2+ G Z1- Z1+ B1- A1- 12V B1+ A1+ G VR 4 3 2 1 G
G CL1 CH1 G RX1 G TX1 T G T/
SYEL srl Via Liguria, 1- 56030 Pontedera Gello (PI) Tel. ++39 0587 294096 e-mail: syel@syel.it web: www.syel.it
UP G R4 G R3 Z4- Z4+ B4- A4- 12V B4+ A4+ G Z4- Z4+ B4- A4- 12V B4+ A4+ G G CL2 CH2 G RX2 G TX2 R G R/ VR 8 7 6 5 G
Vcn E G 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
DOWN
• Digital out
Out connector
Jout 3
2
out
1 Load
Out power-supply
G gnd
Jup Power-supply
E
+24 Vdc (24 Vdc +/- 20%)
Vout
• Digital in-put
In connector
4
3
Jin
2
Input
1
Power-supply
G
Jup E
+24 Vdc
Vout
SYEL srl Via Liguria, 1- 56030 Pontedera Gello (PI) Tel. ++39 0587 294096 e-mail: syel@syel.it web: www.syel.it
CNC Control S4000
• Encoder Line-Driver
Encoder connector
Z1-
Z1+
B1-
A1- Encoder
12V Line-Driver
B1+
A1+
Connected the shield only one side.
G
• Encoder Push-Pull
Encoder connector
Z1-
Z1+
B1-
A1-
12V
B1+ Encoder
A1+ Push-Pull
G
SYEL srl Via Liguria, 1- 56030 Pontedera Gello (PI) Tel. ++39 0587 294096 e-mail: syel@syel.it web: www.syel.it
CNC Control S4000
• Analog out
Analog out connector
G
R2
G GND
Analog out 16 bit (+/-10v)
R1
• Analog in
Analog in connector
VR V reference
4
3
2 Linear
Potentiometer
1 Analog in
G Analog GND
Fig. 1
Fig. 2
V
A load
C
R
SYEL srl Via Liguria, 1- 56030 Pontedera Gello (PI) Tel. ++39 0587 294096 e-mail: syel@syel.it web: www.syel.it
CNC Control S4000
V
load Nided only with loads no
D
drived by electronic
C
Fig. 3
IN THE FIRST PLACE IT MUST SPECIFY THAT EQUIPMENT SYEL ANSWERS TO NORM
“CE”; IT IS THEREFORE TO PRECAUTIONARY SCOPE ONLY RECOMMEND THESE
SAGACITIES,IN PARTICULAR WE REMEMBER THAT THE VALUES FOR THE ANALOG-
IN ARE INFERIOR TO THE mV, THEREFORE FOR HAVING A PRECISE READING TO USE
ALL THE NECESSARY SAGACITIES.
253.0 mm
225.0 mm
133.0 mm
SYEL srl Via Liguria, 1- 56030 Pontedera Gello (PI) Tel. ++39 0587 294096 e-mail: syel@syel.it web: www.syel.it