You are on page 1of 3

Statement of Conformity

OCG5000
Protective overhead line conductor grease.

Conforms to BS EN 50326:2002, type A, designation 20A150


Conforms to IEC 61394:2011, type A, designation 20A150

Approved by National Grid (UK) to NGTS 3.04.37, issue 1


Approved by Eskom (South Africa) to 13TB-015

Test results according to BS EN 50326:2002


Test name/clause Test method Specification Result
IP121 (modified)
Oil separation (6.6.2) <0.2% 0.0%
1 hour at 150°C
Drop point (6.6.3) ISO2176
150°C minimum >300°C
Penetration (6.7.2) ISO2137
>70 mm/10 265 mm/10
-20°C, no cracking, lifting or
Low temperature Bespoke - defined
flaking, grease to remain Complies
adhesion (6.9.3) in standard
completely adhered to plate
Penetration after ageing Penetration must not differ by
ISO2137 -15.8%
test (6.11.4) more than ± 20%
Corrosion on plates Bespoke - defined
≥ Grade 8 Grade 10
(6.12.2) in standard
Corrosion on wires Bespoke - defined No sign of corrosion, pitting,
Complies
(6.12.3) in standard etching or discolouration
Corrosive substances in Bespoke - defined No sign of corrosion, pitting,
Complies
grease (6.12.4) in standard etching or discolouration

Additional test results according to NGTS 3.04.37


Test name/clause Test method Specification Result
IP121 (modified)
Oil separation (3.4.1.1) <0.20% 0.0%
4 hours at 150°C

Global specialists in high-performance lubricants

Metalube Limited, 4 Huntsman Drive, Northbank Industrial Park, Irlam, Manchester M44 5EG, UK
Tel: +44 (0)161 775 7771 Fax: +44 (0)161 775 7511 post@metalube.co.uk www.metalube.co.uk
Company registration number: 2263118; Company registered in England VAT registration number GB108244927000
Statement of Conformity

Additional corrosion performance test


Test name/clause Test method Result
Salt spray corrosion test ASTM B117 NaCl, 3500hrs
Hydrogen Chloride Gas
Hydrochloric acid HCL, 3500hrs
corrosion test

Test results according to IEC61394:2011

Test name/clause Test method Specification Result


Drop point (5.3) ISO2176 150°C minimum >300°C
High temperature IP121 (modified)
<0.2% oil separation 0.0%
stability (5.4) 1 hour at 150°C
Penetration (5.5) ISO2137
>70 mm/10 265 mm/10
-20°C, no cracking, lifting or
Low temperature Bespoke - defined
flaking, grease to remain Complies
adhesion (5.6) in standard
completely adhered to plate
Penetration after ageing Penetration must not differ by
ISO2137 -15.8%
test (5.8.2) more than ± 20%
Corrosion on plates
Bespoke - defined
(5.9) ≥ Grade 8 Grade 10
in standard

Additional test results

Test name/clause Test method Specification Result


IP 121 (modified)
Oil separation <1.5% 0.0%
90 days @ 150°C

Certified on behalf of Metalube Ltd.

C.Nettleship
Technical Director

Global specialists in high-performance lubricants

Metalube Limited, 4 Huntsman Drive, Northbank Industrial Park, Irlam, Manchester M44 5EG, UK
Tel: +44 (0)161 775 7771 Fax: +44 (0)161 775 7511 post@metalube.co.uk www.metalube.co.uk
Company registration number: 2263118; Company registered in England VAT registration number GB108244927000
Statement of Conformity

Date issued: 16th May 2017

Global specialists in high-performance lubricants

Metalube Limited, 4 Huntsman Drive, Northbank Industrial Park, Irlam, Manchester M44 5EG, UK
Tel: +44 (0)161 775 7771 Fax: +44 (0)161 775 7511 post@metalube.co.uk www.metalube.co.uk
Company registration number: 2263118; Company registered in England VAT registration number GB108244927000

You might also like