You are on page 1of 4

OTDR Report (1550 nm (9 µm)) Fail

General Information
File name: Fiber213.trc
Test date: 1/8/2020 Customer:
Test time: 1:48:03 PM Company:
Cable ID: Fiber ID: Fiber213
Job ID:
Comments:

Locations
Location A Location B
Location
Operator
Model FTB-750C-SM1-EA
Serial number 1011772
Calibration date 3/24/2017 (UTC)

Results
Span length: 0.0608 km Average loss: 4.447 dB/km Injection level: 17.3 dB
Span loss: 0.270 dB Average splice loss: ---
Span ORL: <27.76 dB Maximum splice loss: ---

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 9.042 dB/km A-B average loss: 12.786 dB/km
a 0.0000 18.151 A-B LSA loss: 8.357 dB 4-point Event Loss: 20.015 dB
A 0.0196 18.218 A-B ORL: 55.12 dB Maximum reflectance: ---
B 0.9438 6.401
b 1.2506 0.641

Signature: _______________________________ Date: 1/8/2020 Page 1 of 4


OTDR Report (1550 nm (9 µm)) Fail
Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- >-29.1 0.000
Section 0.0608 0.270 4.447 0.270
Non-Reflective 2 0.0608 --- 0.270
Section 0.8879 --- --- ---
Reflective 0.9487 --- -15.6 ---

Macrobend
Position (km) Delta Loss (dB)
0.0608 2.783

Pass/Fail Thresholds
1550 nm (9 µm)
Splice loss (dB) 0.300
Connector loss (dB) 0.750
Reflectance (dB) -40.0
Fiber section attenuation (dB/km) 0.000
Span loss (dB) 20.000
Span length (km) 0.0000
Span ORL (dB) 15.00

Test Parameters
A→B
Wavelength (nm) 1550 nm (9 µm)
Range (km) 1.2500
Pulse (ns) 30
Duration (s) 10

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.468325 1310 nm - 1550 nm 0.500
Backscatter (dB) -81.87
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000

Signature: _______________________________ Date: 1/8/2020 Page 2 of 4


OTDR Report (1310 nm (9 µm)) Fail
General Information
File name: Fiber213.trc
Test date: 1/8/2020 Customer:
Test time: 1:48:15 PM Company:
Cable ID: Fiber ID: Fiber213
Job ID:
Comments:

Locations
Location A Location B
Location
Operator
Model FTB-750C-SM1-EA
Serial number 1011772
Calibration date 3/24/2017 (UTC)

Results
Span length: 0.9487 km Average loss: 8.865 dB/km Injection level: 18.8 dB
Span loss: 8.410 dB Average splice loss: 2.369 dB
Span ORL: <25.80 dB Maximum splice loss: 2.711 dB

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 3.715 dB/km A-B average loss: 7.365 dB/km
a 0.0000 19.538 A-B LSA loss: 3.433 dB 4-point Event Loss: 16.966 dB
A 0.0196 19.564 A-B ORL: 50.03 dB Maximum reflectance: ---
B 0.9438 12.758
b 1.2506 4.721

Signature: _______________________________ Date: 1/8/2020 Page 3 of 4


OTDR Report (1310 nm (9 µm)) Fail
Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- >-29.2 0.000
Section 0.0603 0.484 8.028 0.484
Non-Reflective 2 0.0603 2.711 3.195
Section 0.1340 1.978 14.761 5.173
Non-Reflective 3 0.1943 2.026 7.199
Section 0.7544 1.211 1.605 8.410
Reflective 4 0.9487 --- >-17.3 8.410

Macrobend
Position (km) Delta Loss (dB)
0.0608 2.783

Pass/Fail Thresholds
1310 nm (9 µm)
Splice loss (dB) 0.300
Connector loss (dB) 0.750
Reflectance (dB) -40.0
Fiber section attenuation (dB/km) 0.000
Span loss (dB) 20.000
Span length (km) 0.0000
Span ORL (dB) 15.00

Test Parameters
A→B
Wavelength (nm) 1310 nm (9 µm)
Range (km) 1.2500
Pulse (ns) 30
Duration (s) 10

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.467700 1310 nm - 1550 nm 0.500
Backscatter (dB) -79.45
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000

Signature: _______________________________ Date: 1/8/2020 Page 4 of 4