You are on page 1of 2

OTDR Report (1310 nm (9 µm)) Pass

General Information
File name: FDT EXC_P001_1310.sor
Test date: 18/02/2021 Customer: STC
Test time: 17:48:21 Company: SHAMILA
Cable ID: G657A,SM Fiber ID: 288F,144F
Job ID: 1912000345
Comments:

Locations
Location A Location B
Location FDT EXC
Operator FDT EXC
Model MAX-730C-SM2-EA
Serial number 1227669
Calibration date 28/03/2019 (UTC)

Results
Span length: 1.9714 km Average loss: 0.286 dB/km Injection level: 15.8 dB
Span loss: 0.563 dB Average splice loss: -0.002 dB
Span ORL: 37.18 dB Maximum splice loss: -0.002 dB

Graph

Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 0.370 dB/km A-B average loss: 0.309 dB/km
a 0.3002 15.729 A-B LSA loss: 0.111 dB 4-point Event Loss: 0.179 dB
A 0.6001 15.418 A-B ORL: 44.88 dB Maximum reflectance: ---
B 0.9000 15.325
b 1.2002 15.240

Signature: _______________________________ Date: 27/02/2021 Page 1 of 2


OTDR Report (1310 nm (9 µm)) Pass
Event Table
Type No. Pos./Length Loss Reflectance Attenuation Cumulative
(km) (dB) (dB) (dB/km) (dB)
First Connector 1 0.0000 --- -56.7 0.000
Section 0.5707 0.097 0.170 0.097
Positive* 2* 0.5707 -0.002 0.095
Section 1.4008 0.468 0.334 0.563
Reflective 3 1.9714 --- -49.0 0.563

Macrobend

Pass/Fail Thresholds
1310 nm (9 µm)
Splice loss (dB) 0.100
Span length (km) 0.0000
Span ORL (dB) 15.00

Test Parameters
A→B
Wavelength (nm) 1310 nm (9 µm)
Range (km) 5.0000
Pulse (ns) 30
Duration (s) 8

Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.467700 1310 nm - 1550 nm 0.500
Backscatter (dB) -79.45
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.100
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000

Signature: _______________________________ Date: 27/02/2021 Page 2 of 2