Professional Documents
Culture Documents
General Information
Filename: =E8.sor
Test date: 25/08/2022 Customer:
Test time: 12:31:58 Company:
Cable ID: idea Fiber ID: F61
Job ID:
Comments:
Locations
Location A Location B
Location GND JTP
Operator
Model MAX-715B-P-M1-EA
Serial number 837818
Calibration date 12/05/2015 (UTC)
Results
Span length: 0.4651 km Average loss: 1.162 dB/km Injection level: 24.8 dB
Span loss: 0.541 dB Average splice loss: 0.164 dB
Span ORL: <15.22 dB Maximum splice loss: 0.189 dB
Graph
Markers
Marker Position (km) Value (dB) A-B LSA attenuation: 11.513 dB/km A-B average loss: 25.869 dB/km
a 0.5002 20.298 A-B LSA loss: 0.250 dB 4-point Event Loss: 10.191 dB
A 1.0004 12.940 A-B ORL: 50.67 dB Maximum reflectance: -65.7 dB
B 1.5007 0.000
b 2.0009 0.000
Macrobend
Position (km) Delta Loss (dB)
Pass/Fail Thresholds
1550 nm
Splice loss (dB) 0.300
Connector loss (dB) 0.750
Reflectance (dB) -40.0
Fiber section attenuation (dB/km) 0.400
Span loss (dB) 20.000
Span length (km) 0.0000
Span ORL (dB) 15.00
Test Parameters
A→B
Wavelength (nm) 1550 (9 μm)
Range (km) 5.0000
Pulse (ns) 100
Duration (s) 15
Test Settings
A→B Macrobend Wavelengths Macrobend Delta Loss (dB)
IOR 1.468325
Backscatter (dB) -81.87
Helix factor (%) 0.00
Splice loss detection threshold (dB) 0.020
Reflectance detection threshold (dB) -72.0
End-of-fiber detection threshold (dB) 5.000