BTX The fully modular micro::station combines 1 Terminal 8 Main panel
s::can instruments to a compact and versa- 1
con::cube terminal with moni::tool soft- Material: PP
TOC tile system. It presents a complete solution,
ware for data acquisition, data display Weight of the station (fully equipped):
as the user only has to connect water supply
Ionselective

Ionselective
and station control 20 kg (+/- 1 kg)
DOC and -discharge (“plug & measure”) in order to
Probes

Probes
receive a previously unheard variety of imme-
diately available information and parameters
2
UV254
at no extra cost.
9 Flow restrictor unit
NO3
The s::can micro::station is designed for 2 Spectrometer probe
Physical Probes

Physical Probes
For automatic flow restriction and back-
OnLine monitoring of water quality parameters flow prevention in by-pass
NO2 All s::can spectrometer probes are multi-
in clean media, such as drinking water. The
required components - spectro::lyser, s::can
parameter instruments that can measure 8
NH4 a variety of water quality parameters
probes and controller - are factory assembled

K+
with all required flow cells, mounting fittings
Possible parameters: 3
and pipework on a compact panel.
AOC, BOD, BTX, COD, color, DOC, FTU/
Terminals

Terminals
TCl NTU, H2S, NO2-N, NO3-N, O3, TOC, TSS, 10 Physical probes
micro::station - the s::can solution for water
UV254, fingerprints and spectral alarms,
analysis - compact and easy like never before. Up to four s::can physical probes can be
FCl temperature and pressure
9 installed in one flow cell

F- Possible parameters:
conductivity, FCl, pH, PSU, redox, TCl
Software

Software
TSS 3 Flow cell for spectrometer probe and temperature
Including auto brush cleaning device to
FTU/NTU provide cleaning of the optical measuring
windows
Color 4
10
Configuration

Configuration
System

System
pH 11 Physical probe or ISE probe
Place for oxi::lyser, soli::lyser or s::can
ORP 4 System tubing 11 ISE probe (e.g. ammo::lyser)
Included in panel assembly; Material PU,
Conductivity
Monitoring

Monitoring
inside diameter 6 mm, outside diameter Possible parameters:
Monitoring

Monitoring
Stations

Stations
8 mm F-, K+, NH4-N, NO3-N, O2, pH and
tions

tions
Temperature temperature
5 Flow detector
Sta-

Sta-
O2 The flow detector is set to give an alarm 5
if the flow rate decreases below a critical
O3
Spare Parts &

Spare Parts &


value
Accessories

Accessories
6 Inlet strainer 13
H2S The inlet strainer ascertains that no
coarse material enters the micro::station.
6 12 Flow cell for physical probes
AOC With screw cap for sieve removal/cleaning Combined flow cell for up to four s::can
7 12 physical probes. Provides quick connect/
Fingerprints disconnect design by safety pins to reduce
Services &

Services &
Solutions

Solutions
offline time during sensor maintenance
13 Flow cell for ISE probe
Alarms 7 Pressure transmitter (optional)
Flow cell for one s::can ISE probe
Mounting position for pressure transmitter

© s::can Messtechnik GmbH © s::can Messtechnik GmbH

82 83
micro::station
Spectrometer

Spectrometer
Probes

Probes
Options for s::can micro::station
i::scan

i::scan
1 Terminal con::cube 450
con::lyte eco
420 202
con::lyte pro

2 Spectrometer probe spectro::lyser


carbo::lyser
Ionselective

Ionselective
Probes

Probes
color::lyser
multi::lyser
nitro::lyser
ozo::lyser
uv::lyser
Physical Probes

Physical Probes
3 Flow cell for spectrometer probe flow-cell (by-pass fitting), POM-C (for pathlengths from 1 mm to 35 mm)
flow-cell (by-pass fitting), POM-C (for pathlength 100 mm)
flow-cell (by-pass fitting) autobrush, POM-C (for pathlength 35 mm)
flow-cell (by-pass fitting) autobrush, POM-C (for pathlength 100 mm)

4 System tubing inside diameter 6 mm, outside diameter 8 mm 750 720


Terminals

Terminals
5 Flow detector flow detector

6 Inlet strainer inlet strainer

7 Pressure transmitter pressure transmitter for micro::station (optional)


Software

Software
8 Main panel system panel micro::station US
system panel micro::station EU
system panel micro::station add-on module EU
system panel micro::station add-on module US
Configuration

Configuration
9 Flow restrictor unit automatic flow restrictor unit
System

System
flow adjustment valve

10 Physical probes pH::lyser


redo::lyser n9
135 IN OUT
condu::lyser
Monitoring

Monitoring
Monitoring

Monitoring
chlori::lyser 290
Stations

Stations
tions

tions
11 Physical probe or ISE probe ammo::lyser eco
Sta-

Sta-
ammo::lyser pro
fluor::lyser
oxi::lyser
Spare Parts &

Spare Parts &


Accessories

Accessories
soli::lyser

12 Flow cell for physical probes flow-cell for up to 4 s::can physical probes, POM-C
s::can physical probe flow-cell (by-pass setup), POM-C

13 Flow cell for ISE probe or physical probe ammo::lyser flow-cell (by-pass setup), POM-C
Services &

Services &
oxi::lyser flow-cell