You are on page 1of 6

AMI Turbiwell

Quality Standards for Potable Water

Online Monitoring for

Potable Water
Disinfectants Organics Monitoring - SAC 254
pH Ammonium/Nitrate
Redox Potential (ORP)
Turbidity Dissolved Oxygen
pH
Disinfectants Redox Potential

AMI Codes-II CC

AMI pH/Redox
AMI Codes-II

Photometric measu-
rement and control
Differentiated photo-
metric determination AMI Trides
Amperometric mea-
surement and control
Potentiometric mea-
surement of pH value
system for disinfectant of chlorine according system for disinfectant and/or redox potential
concentrations to AWWA 4500-Cl G / concentrations (single or dual channel )
EN ISO 7393-2

Conforming with Continuous and Reagent-free – low Easy calibration


standard DPD-me- simultaneous operating costs with without sensor
thod according to analysis of free, durable, membrane- disassembling
AWWA 4500-Cl G/ bound and total free sensor design
EN ISO 7393-2 for chlorine Minimized mainte-
free chlorine Low maintenance, nance with integrated
Freely adjustable high zero point sensor cleaning
High accuracy and measuring intervals stability, improved
reproduceability for optimized use longevity with auto- Integrated tempera-
due to automatic of reagents matic sensor cleaning ture measurement
zero-value calibration and compensation
Fast and easy to Reliable measure-
Reduced maintenance ments with integrated
with cleaning module user-friendly solid monitoring of Redox
and high tolerance state standard Potential or pH Value
against fouling (incl. compensation)

Free Chlorine Free Chlorine Free Chlorine pH Range


0-5 ppm 0-5 ppm 0-5 ppm 1-13 pH
Chlorine Dioxide Bound Chlorine Chlorine Dioxide Redox Potential
0-6 ppm 0-5 ppm 0-3 ppm (ORP)
Ozone Total Chlorine Ozone -400 bis +1200 mV
0-2 ppm 0-6 ppm 0-1 ppm
Ammonium
Turbidity Organics Nitrate

AMI ISE Universal


AMI Turbitrack
AMI Turbiwell

Contact-free turbidity ISO 7027 compliant


AMI SAC254
Measurement of UV Ion sensitive deter-
measurement; approved determination of tur- absorption at 254nm mination of Ammonium,
alternative method to bidity under process (SAC 254 ) for moni- Nitrate or Fluoride
US EPA 180.1 / ISO 7027 pressure conditions toring of organic
contamination

Heated optics pre- Sample intake up to Dynamic measuring Low operating


vent measurement 10 bar; no pressure method: Insensitive costs due to
errors and fouling reduction necessary to fouling with wide reagent free
from condensation mea suring range operation
Minimized mainte-
No consumables, nance because of Integrated grab Minimal mainte-
no wearing parts, wiper-free operation sample function nance due to
no follow-up costs integrated sensor
Fast and easy to use Correlation with DOC, cleaning
Automatic measuring TOC and other related
mary and secondary parameters possible Flexibility to monitor
trouble-free operation standard additional parameters
without manual inter- Integrated turbidity with ion sensitive
vention correction at 550 nm electrodes
per DIN 38404-3

tion with primary and


secondary standard

Turbidity Turbidity UV Absorption Ammonium


0-200 NTU 0-100 NTU UVA 0-300 m -1 0-1000 ppm
UV Transmission Nitrate
0-100 % 0-1000 ppm
DOC, TOC Fluoride
Concentration ppm 0-1000 ppm
Dissolved
Conductivity Oxygen
Chematest 30/35
AMI Solicon 4

AMI Oxysafe

Measuring of Amperometric Portable kit for disinfectants, cyanuric


measurement of acid, pH and redox potential measure-
TDS or salinity dissolved oxygen ments. Dust and water protected (IP67),
removable cuvette adapter.

Insensitive to Integrated air pres- Easy handling, reproducible results due


fouling due to sure and temperature to measurements using liquid reagents
4-electrodes compensations for (DPD method)
principle simple calibration
using ambient air Menu-driven user guidance; registration
Measurement of of users and sampling points
Salinity as NaCL Long-term stable
possible measuring system Comfortable measurement of pH and
with robust electrode redox potential (ORP) with external
Easy calibration for low-priced sensors (Chematest 35 only)
without sensor operation
removal Chlorine (free, total, combined)
Easy to handle 0-10 ppm
membrane and Chlorine Dioxide
electrolyte exchange 0-19 ppm
Ozone
0-4 ppm
pH Range (with phenol red)
6.5-8 pH
Dissolved Oxygen Cyanuric acid
0,1 µS/cm-100 mS/cm 0-20 ppm 0-100 ppm
Salinity (as NaCl) Saturation
0-4 % 0-200 % via sensor connections (CT35 only):

0-20 g/l pH range


1-13 pH
Redox potential (ORP)
-400 - +1200mV

Other parameters: see datasheet


Swan
Monitor Concept

Swan instruments are delivered as fully functional,


ready-to-use instruments. This ensures easy system
integration as well as user-friendly operation and
maintainability.

Highest standards in development and production


assure the instrument quality expected by our
customers.

System Integration Service and Maintenance Quality Assurance

Complete panel-moun - Uniform menu navigation Every analyzer is


ted systems with for simple operation and wet bench tested
maintenance - one trans - and factory cali-
gured for quick start up mitter for all instruments brated prior to
delivery
Various communication Clearly arranged setup
- of instruments, easy Automatic tracing of
bus, Modbus, HART - accessability of all com- reagent charging level
Protocol, USB -interface and sensor functions
and analog output maintenance by the instrument

Simple process engi- Self-explanatory main -


neering with regulation tenance procedures can for validity check
functions ( P, PI, PID or be easily performed by
PD ), relay or analog the operating company
output
Headquarters: Sales & Customer Service ME:
Swan Analytical Instruments Swan Analytical Middle East FZE
Studbachstrasse 13 LB 19, 2004 JAFZA View 18 & 19
8340 Hinwil ∙ Switzerland P.O. Box 263219, Jebel Ali Free Zone
Hotline: 0901 866 299 UAE-Dubai
swan@swan.ch Hotline: 0901 866 299
www.swan.ch sales@swananalyticalme.com
www.swan.ch

Sales & Customer Service SG:


Swan Analytical Singapore Pte Ltd.
55 Serangoon North Avenue 4
#01-14, S9 Building
SG-555859 Singapore
Hotline: 0901 866 299
The Swan group '
morris.teo@swan.sg
www.swan.ch

Represented by:
Sales & Customer Service UK:
Swan Analytical UK Ltd.
Swan Analytical Vietnam
WNW Building, 236/43/2 Dien Bien Phu, Unit 3 The Steading, Copthill Farm
Ward 17, Binh Thanh District, Deeping Road
Ho Chi Minh City, Vietnam Stamford PE9 4TD
Hotline: 0901 866 299 Hotline: 0901 866 299
sales@swanvietnam.vn
www.swanvietnam.vn sales@swan-analytical.co.uk
https://uk.swan.ch

Sales & Customer Service ZA:


Swan Instrumentation South Africa (Pty) Ltd.
Unit 13 Aquaplan Business Park
120 E P Malan Road, Pomona
ZA-Kempton Park 1619
Hotline: 0901 866 299
sales@swan.za.com
www.swan-analytical.co.za

© Swan 202001