SITRANS WS300
SITRANS
Safety Guidelines: Warning notices must be observed to ensure personal safety as well as that of
others, and to protect the product and the connected equipment. These warning notices are
accompanied by a clarification of the level of caution to be observed.
Qualified Personnel: This device/system may only be set up and operated in conjunction with this
manual. Qualified personnel are only authorized to install and operate this equipment in accordance with
established safety practices and standards.
Unit Repair and Excluded Liability:
• The user is responsible for all changes and repairs made to the device by the user or the user’s
agent.
• All new components are to be provided by Siemens Milltronics Process Instruments Inc.
• Restrict repair to faulty components only.
• Do not reuse faulty components.
Warning: Cardboard shipping package provides limited humidity and moisture protection. This product
can only function properly and safely if it is correctly transported, stored, installed, set up, operated, and
maintained.
This product is intended for use in industrial areas. Operation of this equipment in a residential area
may cause interference to several frequency based communications.
i
ii
Safety Notes1
Special attention must be paid to warnings and notes highlighted from the rest of the text
by grey boxes.
1.
This symbol is used when there is no corresponding symbol on the product.
This instruction manual covers the installation, operation and maintenance of the WS300
speed sensor.
We strongly recommend reading this manual, and any manual for a product used in
conjunction with the WS300 (such as a belt scale integrator), for proper installation and
operation of any component of the weighing system. Adhering to the installation and
operating procedures ensures a quick, trouble-free installation and allows for the
maximum accuracy and reliability of your weighing system.
Integrator and speed sensor instruction manuals are available for download from
www.siemens.com/processautomation.
We always welcome suggestions and comments about manual content, design, and
accessibility. Please direct your comments to techpubs.smpi@siemens.com.
Technical Support
Support is available 24 hours a day.
To find your local Siemens Automation Office address, phone or fax number go to:
www.siemens.com/automation/partner
•Click on the tab Contacts by Product and then find your product group (+Process
Automation > +Weighing Technology).
•Select the team Technical Support. Click on Next.
•Click on the appropriate continent, then select the country followed by the city.
Click on Next.
The WS300 sensors can also be used with older model Siemens integrators:
• Compuscale • Compuscale IIA • Compu-M
• Compuscale II • Compuscale III
Ambient Temperature
• standard: -40 to +55 °C (-40 to +131 °F)
• IS: -25 to +60 °C (-13 to +140 °F)
Input
• shaft rotation 0.5 to 2000 rpm, bi-directional, resolution dependent
Output
• uni-directional open collector sinking output
• standard: +10 to +30 V DC, 25 mA max.
• IS: load current, 0 to 15 mA
• 32, 256, 1000, or 2000 pulses per revolution (PPR)
Enclosure
• aluminum, rated NEMA 4X/Type 4X/IP65
• stainless steel (optional), rated NEMA 4X/Type 4X/IP65
Cable (recommended)
• standard: 3-wire shielded, 0.82 mm2 (18 AWG)
• IS: 2-wire shielded 0.324 mm2 (22 AWG)
• maximum cable run 305 m (1000 ft)
Weight
• 1.22 kg (2.68 lbs) aluminum
• 2.41 kg (5.3 lbs) stainless steel
Note: The device nameplate lists the approvals that apply to your device.
• standard version:
• General CE, C-TICK
• Hazardous CSA/FM Class II, Div. 1, Groups E, F, G; Class III
ATEX II 2D Ex tD A21 IP65 T70 °C
IECEx Ex tD A21 IP65 T70 °C
• IS version:
• General CE, C-TICK
• Hazardous Intrinsically Safe (IS) rating based on Switch and
Isolator Approvals (see below)
Switch and Isolator Approvals
Note: The Approval Ratings for the Proximity Switch and the IS Switch Isolator
are the property of Pepperl + Fuchs. Copies of these Approval Certificates may be
obtained from our website www.siemens.com/continuous-weighing. Click on
Support, then Approvals / Certificates, to find the appropriate certificate.
1.
Based on the ATEX rating of the NAMUR sensor and CSA/FM system approvals.
Dimensions
305 mm
(12.0")
50 mm 131 mm
(1.96") (5.16")
89 mm
Rod ø: (3.5")
8.0 mm
(5/16")
60 mm
Shaft ø: 15.9 mm (2.38")
(5/8")
102 mm
(4.03")
½" NPT conduit entrance
(optional M20 adapter available)
102 mm 159 mm
(4.00") (6.25")
111 mm
(4.36")
When mounting, make sure the unit and the pulley shaft are concentric to avoid stresses
on the unit’s bearings.
For preferred mounting locations, refer to the associated belt scale or weigh feeder
instruction manual.
For shafts that do not have enough material protruding to use a set screw, or that cannot
be removed for modification, a threaded shaft coupling can be used.
≥ 10 mm (0.375")
89 mm
(3.5")
WS300
flexible conduit
Notes:
• Distance (d) is the take up travel on the tail pulley
• When adjusting the belt take up, ensure there is play on the arrestor rod. If the
arrestor rod is pushed against the end of its travel slot, premature wear may
result on the bearing.
WS300
belt
flexible conduit
tension spring
stringer
89 mm
3.5"
WS300
flexible
conduit
pulley bearing
Note: When mounting to a bend or snub pulley only a 3/8” (10 mm) drilled hole is
required for the arrestor rod.
.254mm (.010") A
A
M12x1.75 (use adhesive
when installing threaded
shaft coupling (e.g. Loctite)
Note: All other installation instructions apply. See “General Installation Steps” on
page 11.
3. Attach angle iron bracket to work with the arrestor rod (if mounting on a tail pulley).
4. Cut the arrestor rod to a suitable length.
5. Insert the WS300 shaft into the pulley shaft and lock with set screw on flat of shaft.
Example slot for 127 mm
arrestor rod (5") approx. secure
when mounted to with
tail pulley - use bolt or
drilled hole for post
snub or bend
pulley
Interconnection between the standard WS300 unit and the integrator should be made
with three-wire shielded, 0.82 mm2 (18 AWG) cable. To connect the WS300 IS unit to the
switch isolator, use two-wire shielded 0.324 mm2 (22 AWG) cable. Use the same cable to
connect the switch isolator to the integrator.
For both units, ground the shield at the integrator end ONLY. Connect shield to
appropriate terminal at the integrator.
Notes:
• Flexible conduit is recommended so that excess stress is not applied to the
shaft bearings.
• Use appropriate conduit and conduit fittings or cable glands to maintain NEMA
or IP rating.
Standard Intrinsically
Version Safe Version
1
GND
GND – Ground
A ground connection. Do not use this ground for the cable shield.
Notes:
• Ground the cable shield at the integrator end only!
• For optimal performance the housing of the Speed Sensor must be connected
to a reliable earthed ground.
Note:
• N/C indicates the terminal is not normally connected.
Determine the pulley shaft rotation on the end of the pulley shaft to which the WS300 is
attached.
If the pulley shaft rotates clockwise, connect the appropriate wire to terminal 2.
If the pulley shaft rotates counter-clockwise, connect the appropriate wire to terminal 3.
2 – Speed Out
The positive output connection of the measurement loop.
GND – Ground
A ground connection. Do not use this ground for the cable shield.
Notes:
• Ground the cable shield at the integrator end only!
• For optimal performance the housing of the Speed Sensor must be connected
to a reliable earthed ground.
Inspection
Periodically the cover should be removed and the enclosure and circuit board should be
cleaned for dust and grime buildup. If cleaning is required, disconnect the power and use
a vacuum cleaner and a clean, dry paintbrush. While the cover is off, check all electrical
contacts for corrosion and evidence of arcing.
Wear on the bearings is detected by excess play or sound. If the bearings exhibit excess
play or produce an unreasonably loud sound, the speed sensor should be returned to
Siemens for repair.
Product Nameplates
Note: The nameplate shown is a typical example. Please check the nameplate on
your device for your specific device configuration.
SIRA 06ATEX9303X
IECEx SIR 08.0070X
159134
Do Not Open When An Explosive Dust Atmosphere is Present
Notes
IQ300IX.fm Page 5 Tuesday, October 2, 2001 1:43 PM
www.siemens.com/processautomation
www.siemens.com/continuous-weighing
Siemens Milltronics Process Instruments Inc. Subject to change without prior notice
Industry Automation (IA) 7ML19985ML01 Rev. 1.1
1954 Technology Drive
P.O. Box 4225
Peterborough, ON
Canada K9J 7B1
© Siemens Milltronics Process Instruments Inc. 2010
*7ml19985ML01*
Printed in Canada
email: techpubs.smpi@siemens.com
www.siemens.com/processautomation