HEAT INSULATION
A special low-emissivity (low-E) coating of selective glass does not let heat out of
premises, but lets in solar heat radiation. This additional energy enables reduced
heating expenses during cold season. This is the best glass choice for windows in
dwelling houses. The coating is usually on the third surface of double glass unit.
LOWE GLASS 1.1

Insulating Coating Gas Light Trans- Light Colour Solar Ug-Value


Glass on Glazing Filling mission Reflection Rendering factor (g) EN 673 (15K)
Unit Surface % % Index Ra EN 410 % W/(m2K)

4-16-4 3 Argon 80 12 97 63 1,1

4-14-4-14-4 2 + 5 Argon 71 15 96 49 0,6

LOWE GLASS 1.0

Insulating Coating Gas Light Trans- Light Ref- Colour Solar Ug-Value
glass confi- on surface filling* mission % lection Rendering Factor (g) EN 673 (15K)
gurations % Index Ra EN 410 % W/(m2K)
4-16-4 3 Argon 70 20 97 53 1,0
4-16-4-16-4 2 + 5 Argon 56 29 95 37 0,5
4-12-4-12-4 2 + 5 Krypton 56 29 95 37 0,4

* Gas filling rate: 90%


All values are nominal values and are subject to production tolerances

SOLAR CONTROL
• Body-tinted glass protects from solar energy by absorbing it. Protection
UPB holding comprises AILE Group, a major rate depends on glass color and thickness. Range of colors: green, grey, bron-
manufacturer of glass structures in the Baltic ze, blue. The thicker glass is, the darker the color tint is.
countries. SIA Stiklu Centrs is one of AILE group’s • Clear and body-tinted glass with reflective coating protects from solar
energy by absorbing and reflecting it. Light and solar energy transmission
structural units that launched its operation on 25 April depends on glass color and thickness as well as on the type of coating. The
2000. It specialises in the manufacture of insulated coating is usually on the second surface.
• Glass with combined low-E coating protects from solar energy and ensures
glass units and structural glass for various sites. High high heat insulation characteristics. Solar heat radiation is restricted in premi-
quality products are manufactured in production unit ses; therefore it is possible to decrease the use of air-conditioning equipment.
It is ideal for large glass surfaces. The coating is always on the second surface.
in Liepāja, according to European standards, which
SunGuard® High Selective - HT
are proved by the Danish DS Certificering A/S certificate
Product Visible Light Solar Energy Solar Shad. U-Value
No 2172 granted in June 2008, by SP Technical

(EN 410)

(EN 410)
g EN/
Factor (g) Coeff. (EN 673)

Research Institute of Sweden Marking permit No




Trans- Reflec- Reflec- Direct

Reflec- Absorp. EN DIN
0.87
Air Argon(*)
mission tion Out- tion in- Transmis- tion Out- % 410 67507 W/ W/
210-09-0066 granted in March 2009, as well as LLDRA % door % side % sion % door% % % (m2K) (m2K)

certificate No 090636 granted in June 2009. Double Glazing 6-16-4, SunGuard® coating on face #2
Super Neut-
ral 70 - HT 70 11 12 39 34 28 41 38 0.47 1.4 1.1

State-of-the-art equipment, certified materials, Super Neut-


ral 62 - HT 62 15 17 32 37 31 34 32 0.39 1.3 1.1
experienced employees and ISO 9001:2008 quality Super Neut-
ral 51 - HT 51 12 23 26 37 37 28 26 0.32 1.3 1.1
management system introduced by the company in Super Neut-
ral 40 - HT 40 16 32 21 36 43 23 22 0.26 1.3 1.1
2004 ensure constant high quality of manufactured
products. SIA STIKLU CENTRS employees offer HT = Heat-Treatable version

consultations with regard to the selection of glass SAFETY AND SECURITY


and assist in solving technical issues. • Toughened glass – the heat-processed glass, five times stronger than ordinary
float glass. If broken, splits into small pieces, safe for human health. This type
of glass is used to make glass barriers, partitions and doors, windows, planar
Lisec, Bottero, Pannkoke and other manufacturers’ systems etc. Available as clear and tinted, with low-E and solar control coatings.
equipment is used in manufacturing. Maximum Safety Glass according to EN 12600

dimensions of insulated glass units are 2500 x 3500 mm. Product Type Struc- Safety Dimensions Production Dimensions
ture Class 1) Thickness Tolerance Weight Min. Max.
3-1 mm +/- mm kg/m2 mm mm
The glass suppliers are Euroglass, Guardian, AGC, Toughened Glass 4 1(C)2 4 0,2 10 200x350 3210x6000

Pilkington and other manufacturers. We offer glass Toughened Glass 6 1(C)2 6 0,2 15 200x350 3210x6000
Toughened Glass 10 1(C)1 10 0,3 25 200x350 3210x6000
that can be used to perform various functions.
Pilkington Pyroshield Safety, Pilkington Pyrodur and Pilkington Pyrostop

• Laminated glass – made from two or more glass sheets that are attached
to each other using a clear or tinted polymer foil (PVB) or a special resin (CIP).
This type of glass is used for skylights, door entrance blocks, shop windows,
in banks and offices. Also available with low-E coating.
Safety class according to EN 12,600 Security class according to EN 356

6.4 Laminated 2(B)2


6.8 Laminated 1(B)1 P2A
8.4 Laminated 2(B)2
8.8 Laminated 1(B)1 P2A
9.1 Laminated P3A
9.5 Laminated P4A

11.0 Laminated P5A

• Wired glass (Pilkington Pyroshield; AGC Wired) – monolithic glass with inte­
1st cover: Stiklu Centrs plant in Liepaja grated wire mesh. Used for skylights, doors, other constructions for the safe-
Railway Station Umea Östra, Sweden, 2009 ty and fire protection.
NOISE CONTROL
• Glasses of various thickness in an insulating glass unit is the simplest and
cheapest method.
• Laminated glass with acoustic PVB foil – used on its own, and in insulated
units.
First glass Second glass Rw*, dB Rw+C**, dB Rw+Ctr, dB
4 Clear Float 4 Clear Float 29 28 25
6 Clear Float 4 Clear Float 32 30 28
8 Clear Float 4 Clear Float 37 35 32

Performance data – single glazing

Type Glazing Interlayer Thickness Rw Ctr Safety level Safety level


mm dB dB Ball drop Pendulum Impact
EN 356 EN 120 600
SC 44.2 4/0,76/4 SC 9 37 -3 P1A 1(B)1
SC 44.4 4/1,52/4 SC 10 37 -3 P2A 1(B)1
SC 55.2 5/0,76/5 SC 11 38 -3 P1A 1(B)1
SC 66.2 6/0,76/6 SC 13 40 -3 P1A 1(B)1
SC 88.2 8/0,76/8 SC 17 42 -3 P1A 1(B)1

Performance data – insulating glass

Type Glazing Interlayer Thickness Rw Ctr Safety level Safety level


mm dB dB Ball drop Pendulum Impact
EN 356 EN 120 600
25/36 44.2/12/4 PVB 25 36 -5 P2A 1(B)1
27/37 33.4/16/4 PVB 27 37 -6 P4A 1(B)1
29/39 44.2/16/4 SC 29 39 -5 P1A 1(B)1
31/41 44.2/16/6 SC 31 41 -6 P1A 1(B)1
33/41 44.2/18/6 SC 33 41 -7 P1A 1(B)1
33/42 44.2/16/8 SC 33 42 -7 P1A 1(B)1
37/43b 66.2/16/8 SC 37 43 -6 P1A 1(B)1
35/44b 44.2/16/10 SC 35 44 -6 P1A 1(B)1
39/45a 44.2/20/10 SC 39 45 -6 P1A 1(B)1
Production unit and manufacturing process at Stiklu Centrs
38/47 44.2/16/66.2 SC/SC 38 47 -6 P1A 1(B)1
38/48 44.2/16/66.3 SC/SC 38 48 -8 P1A 1(B)1
41/49 44.2/20/66.2 SC/SC 41 49 -7 P1A 1(B)1
42/50 44.3/22/66.3 SC/SC 42 50 -7 P1A 1(B)1
46/51 88.2/16/66.2 SC/SC 46 51 -5 P1A 1(B)1

PVB is Polyvinyl-Bytiral-Interlayer * Rw is weighted sound reduction index, in decibels; ** Rw+C and Rw+Ctr are
SC is Sound-Control-PVB-Interlayer the sound reduction indexes, adapted to household and transport-related noise.

DECORATIVE GLASS
• Glass with textured surface (AGC Imagin) ensures good light transmission
and limited transparency at the same time. Used for glazing of partition walls,
windows and doors.
Toughened enamelled glass with all surface painting or screenprinted pat-
tern. Used for decorative partitions and spandrels. The enamel is resistant
against mechanical damages, and it does not fade.

FIRE PROTECTION GLASS


• Reinforced and special hardened glass (Pilkington Pyroshield; AGC Wired,
SGG Pyroswiss) – in case of fire does not lose transparency; keeps flames and Manufacturing
hot gases from spreading for a certain period of time (E class). process and product
• Multi-layer laminated glass (Pilkington Pyrodur, Pyrostop; AGC Pyrobelite, quality compliance
Pyrobel; SGG Contraflam, Swissflam) – construction of a number of hardened certificates
or unhardened glasses, which becomes nontransparent in case of fire. Keeps
flames and hot gases from spreading and partly or fully protects from high
fire temperatures (EW and EI class).

CURVED GLASS
Stiklu Centrs represents the Finnish company Tambest offering curved
glass and insulating glass units. More details at www.tambest.fi.

MATERIALS AND OPTIONS


We offer insulating glass units with decorative Georgian bars and muntin bars
as well as with built-in Venetian blinds by the Danish company Hagen. More
details at: www.hagen.dk.
We use Schüco and Profilglass aluminum spacers and warm edge materials – plastic
combined with stainless steel Thermix®TX.N produced by Ensinger GmbH, TGI warm
edge spacers produced by Technoform Glass Insulation GmbH and stainless steel
spacers. Warm edge spacer bars minimize heat loss and combat condensation on
the inner pane. Comparison of heat losses in windows through edges of insulating
glass units, where U-value for glazing is 1.2W/m2K and for the frame 1.4W/m2K
In order to improve heat insulation, we offer double and triple insulating glass
units with argon filling. In order to absorb dampness in insulation units, spacers
are filled with the desiccant W 558 made by Grace GmbH & Co.KG. We use edge
sealants: butyl Totalseal 3524/1 and polyurethane Totalseal 3189/2 by Le Joint
Français, and silicone materials DC 993 and DC 3362 made by Dow Corning for
the production of structural glazing. Successful cooperation with our custom-
ers ensured by the high technical characteristics and reasonable price of our
product, as well as by possible fast and precise delivery. We carry out the orders
within short periods of time and deliver those at a certain time and place.
Grjothals Brewery Faculty building
in Reykjavik, of Ruhr University,
Iceland, Bochum, Germany,
2009 2010

Kriminalvards- Crowne Plaza Hotel


byggnad Detention in complex Copenha-
Facility in Göteborg, gen Towers in Copen-
Sweden, hagen, Denmark,
2009 2009

Marriott Hotel Railway Station


Snöflingan in Umea Östra,
Stockholm, Sweden, Umea, Sweden,
2009 2009

STIKLU CENTRS UPB Export Department


Production unit Maskavas iela 250
Pulvera iela 20 Riga, LV-1063
Liepāja, LV-3417 Phone +371 6 7844680
Phone +371 6 3489120 Fax +371 6 7844690
Fax +371 6 3489119 E-mail: exd@upb.lv
E-mail: scl@stiklucentrs.lv www.upb.eu.com

www.stiklucentrs.lv

You might also like