Point of ● Run CPU ● DI120-150

TCD - 217 Hall Button Jam Detection Application


Detection ○ Speed CPU ● DI180-420

[Actions to take]
[Meaning] Hall button jam occurs
Check the floor indicated on the hall button where the button jam
occurs, direction call chime/kong, etc. and maintain hall buttons.
[Explanation]

When a hall button is kept in jammed for 3 minutes or more.

UP Direction Button Jam Floor DOWN Direction Button Jam

Variable: ButtonJamUpFloor Variable: ButtonJamDnFloor


Bit Set Pattern Bit Set Pattern

ADDR : 0x8050 1~8 Fl ADDR : 0x8060 1~ 8 Fl


0x8051 9~16 Fl 0x8061 9~16 Fl
0x8052 17~24 Fl 0x8062 17~24 Fl
0x8053 25~32 Fl 0x8063 25~32 Fl
| | | |
0x805F ~ 128 Fl 0x806F ~ 128 Fl

[Symptoms]

Hall button where button jam occurs is restrained from input.