You are on page 1of 4

OLYMPOS PC

UNIFORM FLOW RATES


OVER FLAT & SLOPING TERRAIN
O LY M P O S P C

OLYMPOS PC
Flow Regulating Drip Line

Drip Line OLYMPOS


Flow Rates (l/h) 1.0, 2.0
Standard Emitter Spacings 15 - 100 cm (depending on wall thickness)
Nominal Drip Line Diameter (mm) 16, 17, 20
16 mm: 15, 18, 35, 40 mil
Drip Line Wall Thickness 17 mm: 25, 35 mil
20 mm: 40, 45 mil
Outlet Hole outlet

www.eurodrip.com
OLYMPOS PC

START OF VINEYARD ROW


ELEVATION: 5.0 m
PRESSURE: 1.5 bar (the pressure at start of lateral)
ACTUAL FLOW RATE FOR 2.0 l/h NON-PC DRIP LINE: 2.0l/h
ACTUAL FLOW RATE FOR 2.0 l/h OLYMPOS PC DRIP LINE: 2.0 l/h

5.0 m
ELEVATION
END OF VINEYARD ROW VARIATION
ELEVATION: 0.0 m (variation -5.0m)
LATERAL LENGTH: 125 m
PRESSURE: 1.9 bar (increased pressure due to gravity)
ACTUAL FLOW RATE FOR 2.0 l/h NON-PC DRIP LINE: 2.5l/h (+25%)
ACTUAL FLOW RATE FOR 2.0 l/h OLYMPOS PC DRIP LINE: 2.0 l/h (constant)

CFD modelling in the


aerospace industry

CFD modelling of
OLYMPOS PC diaphragm
CFD modelling of OLYMPOS PC flow path simulation to maximize fluid turbulence
OLYMPOS PC

OLYMPOS PC
CONSTANT FLOW OVER WIDE PRESSURE RANGES.
IRRIGATE SLOPING TERRAIN WITH CONSTANT FLOW.
= UNIFORM CROPS
= MORE EFFICIENT IRRIGATION
= IRRIGATE LONGER RUN LENGTHS WITH UNIFORMITY

OLYMPOS PC: DESIGNED USING COMPUTATIONAL FLUID


DYNAMICS (CFD) MODELLING

Computation Fluid Dynamic Modelling (CFD) utilizes advanced computer


modelling and algorithms to calculate fluid flows.

CFD is used commonly in the aerospace industry with initial 3D software


development by NASA. Now this advanced method of fluid modelling has
been used to develop the OLYMPOS PC emitter.

Using state of the art technology, the Eurodrip R&D team are able to model water
within the emitter to design drip line that provides constant flow over wide
pressure ranges, while also minimizing the risk of clogging.
OLYMPOS PC

OLYMPOS PC Technical Data


Nominal Wall Internal Drip Maximum Roll Length Flow Maximum Run Length* x
Ø Thick- Ø Line Operating (according Rate Spacing Between Emitters (cm)
ness Coiling Pressure to emitter
spacing) 15 20 25 30 33 40 50 60 75

(mm) (mil) (mm) (bar) (m) (l/h) (m) (m) (m) (m) (m) (m) (m) (m) (m)
850 (20 cm) 1.0 134 172 207 241 260 303 361 415 491
15 16.1 FLAT 2.1 900 (25 cm)
950 (≥30 cm) 2.0 86 110 133 154 167 194 232 266 315

1.0 134 172 207 241 260 303 361 415 491
750 (20 cm)
18 16.1 FLAT 2.3
800 (≥30 cm)
2.0 86 110 133 154 167 194 232 266 315
16
1.0 119 154 187 218 236 277 332 383 455
35 14.2 FLAT 3.0 450 (≥30 cm)
2.0 76 98 119 139 151 178 213 246 293

1.0 126 163 198 232 251 294 353 407 485
40 14.2 ROUND 4.0 500 (≥15 cm)
2.0 85 110 134 156 169 199 238 275 328

750 (20 cm) 1.0 147 189 228 265 287 334 398 457 541
25 16.1 FLAT 2.5 650 (25 cm)
650 (≥30 cm) 2.0 94 121 146 170 183 214 255 293 347
17
1.0
Available upon
35 16.1 FLAT 3.0 Available upon request
request
2.0

1.0 214 271 325 374 403 467 552 631 741

O LY M P O S P C
40 17.5 ROUND 4.0 400 (≥15 cm)
2.0 144 183 219 253 273 316 374 427 502
20
1.0 214 271 325 374 403 467 552 631 741
45 17.5 ROUND 4.0 400 (≥15 cm)
2.0 144 183 219 253 273 316 374 427 502

* At maximum operating pressure

This literature has been compiled for worldwide circulation and the descriptions, photos, and information are
for general purpose use only. Please consult with an irrigation specialist and technical specifications for proper
use of products. Because some products are not available in all regions, please contact your local dealer for

www.eurodrip.com details. Every effort has been used to ensure that product information, including data sheets, schematics,
manuals and brochures are correct. However, information should be verified before making any decisions
based on this information. Eurodrip reserves the right to change specifications and the design of all products
without notice.
EUR_BR_Olympos brochure_R6_EN_W18_0114