You are on page 1of 6

Receptacles

Floor Junction Box Garage Door Opener w/ Outlet


.
(Indicate Size & Type if required)

Single Receptacle
indicate non-standard Height
mounting height
*
* GFI (Ground Fault Interrupt)
* IG (Isolated Ground)
* S (integral Switch
* WP (Weather Proof)
XP (Explosion Proof)

Duplex Receptacle
indicate non-standard Height
mounting height
*
* GFI (Ground Fault Interrupt)
* IG (Isolated Ground) GFI

* S (integral Switch
* WP (Weather Proof)
XP (Explosion Proof)

Quadraplex Receptacle
Floor Special Purpose
indicate non-standard Height
Receptacle
mounting height
*
(Inidcate Configuration)
* GFI (Ground Fault Interrupt)
* IG (Isolated Ground)
Floor Telephone Outlet
* S (integral Switch
* WP (Weather Proof)
Floor Data
XP (Explosion Proof)
Communications Outlet

Special Use Receptacle Range Outlet


indicate non-standard Height R

mounting height
Split Wired Duplex
* GFI (Ground Fault Interrupt)
Receptacle Outlet
* IG (Isolated Ground)
* S (integral Switch Fan Hanger Receptacle F
* WP (Weather Proof)
XP (Explosion Proof)
Television Outlet Height
Height (indicate nonstandard TV
Clock Receptacle
C Mounting Height)
indicate non-standard
mounting height
Switch
none single pole
Data Communications 2 two pole
Height Height
indicate non-standard 3 three way
S

mounting height 4 fourway *


D door
Telephone Outlet K key operated
Height
indicate non-standard LV low voltage
mounting height M momentary

Single Floor Receptacle


Dimmer Switch
indicate non-standard Height
indicate non-standard
mounting height
* mounting height
* GFI (Ground Fault Interrupt)
* IG (Isolated Ground)
* S (integral Switch Ceiling Pull Switch S

* WP (Weather Proof)
XP (Explosion Proof) Switch and Single
Receptacle S

Duplex Floor Receptacle


indicate non-standard Switch and
S
mounting height Double Receptacle
*
* GFI (Ground Fault Interrupt)
* IG (Isolated Ground) PlugMold Height
* S (integral Switch indicate spacing
* WP (Weather Proof) & mounting height
XP (Explosion Proof)
Lights &
Switches
CLG. MTD. Halogen or Incand. H (HALOGEN)
Garage Door Opener
w/ Outlet & Light

CLG. MTD. INC. Halogen Light


W.P. W.P.

WALL MTD. INC. Light Fixt.


Weather Resistant W.R.

WALL MTD. Fluoresent Light F


Fixt.

CLG. Hung or Recessed F


Fluoresent Light Fixture
F Hung

Wall MTD. INC. Light Fixture


Indoors

CLG. Recessed Inc. Light


Fixture

CLG. Recessed Fluoresent Light


F
Fixture and Fan Combo. F

CLG. Recessed Inc. and Heat


Lamp Combo Fixture H

dir
Recessed Directional or Down
Lite Low Voltage Halogen

CLG MTD. Fluoresent Light 4'


Fixture 4' Length

CLG MTD. Fluoresent Light 4'


Fixture 2' Length

Under Cabinet/Cup BD. MTD.


Strip INC. Light Fixture

CLG. Recessed Ventilation Fan

Wall MTD. Recessed Ventilation


Fan

Wall MTD. Light Switch S

Wall MTD. Weather Resistant


Light Switch or Elect. Outlet
WR WR S
Wall MTD. Three Way Light 3
Switch S S3W
Wall MTD. Switch Controled
Electrical Outlet S
CLG. MTD. Motion Sensor M
Detector Switch

Photo-Cell Light Switch P

Door-Activated Automatic
Concealed Switch
SA
Ceiling Hung INC. Ornamental Recessed Direction or
Chandlellier Light Fixture Down Lite Low Voltage
Halogen Four Pack Units
Rail or Wire Directional or dir
Down Lite Low Voltage Halogen
Utility & Safety
Service Weatherhead
Meter
* A - Ammeter
* KW - Kilowatt
* KWD - Kilowatt Demand *
* KWH - Kilowatt Hour
* M - Meter
* P - Power
* V - Volt
* VAR - VAR Meter

Battery

Lightning Arrester

Drawout Connection

Flame Detector

Heat Detector

Smoke Detector S
* I - Ionization *

* P - Photoelectric

Gas Detector
* Type *
Sensor
* H - Humidity *
* P - Pressure
* T - Temperature

Pnematic Thermostat T
* A - Aspirating *
* C - Cooling
* D - Day
* D/N - Day Night
* H - Heating
* H/C - Heating/Cooling
* N - Night

Electric Thermostat T
* A - Aspirating *
* C - Cooling
* D - Day
* D/N - Day Night
* H - Heating
* H/C - Heating/Cooling
* N - Night

H
Humidistat

Sensor
* H - Humidity S
* P - Pressure *
* T - Temperature
Wiring
Capacitor Junction Box J

Generator G

Disconnect/Interupt
Y-Connection, Low
or Medium Voltage

Disconnect Switch Delta Connection, Low


or Medium Range

Circuit Breaker, 52
Fused Disconnect Medium Voltage
Disconnect/Interrupter
Switch, Medium Voltage
(Indicate Size)
Ground Connection
Pull Station, Fire Alarm F

Fire Alarm Horn/Strobe F

Fire Fighter Phone


F
Transofrmer Low Volt
Fire Alarm Bell F

Flush Mounted Magnetic Hold Open Device M


Panel Board Speaker
* F - Fire
* NC - Nurse Call S
*
Surface Mounted * PA - Public Address
Panel Board
Clock
Height

Buzzer
Rigid Conduit
(Indicate Size & Material)
Buzzer & Bell

Flexible Conduit
Bell
(Indicate Size & Material)

Push Button Switch *


HomeRun to Panelboard
(Indicate Circuit & Panel)
PE
Photoelectric

Wiring Neutral

Switch

Wiring Hot

Electric Resistence Heater


Wiring Switch Ground

Wiring Switch Leg


Clouds
Arch Fonts
Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

Framing Framing Framing Framing

You might also like