Professional Documents
Culture Documents
Single Receptacle
indicate non-standard Height
mounting height
*
* GFI (Ground Fault Interrupt)
* IG (Isolated Ground)
* S (integral Switch
* WP (Weather Proof)
XP (Explosion Proof)
Duplex Receptacle
indicate non-standard Height
mounting height
*
* GFI (Ground Fault Interrupt)
* IG (Isolated Ground) GFI
* S (integral Switch
* WP (Weather Proof)
XP (Explosion Proof)
Quadraplex Receptacle
Floor Special Purpose
indicate non-standard Height
Receptacle
mounting height
*
(Inidcate Configuration)
* GFI (Ground Fault Interrupt)
* IG (Isolated Ground)
Floor Telephone Outlet
* S (integral Switch
* WP (Weather Proof)
Floor Data
XP (Explosion Proof)
Communications Outlet
mounting height
Split Wired Duplex
* GFI (Ground Fault Interrupt)
Receptacle Outlet
* IG (Isolated Ground)
* S (integral Switch Fan Hanger Receptacle F
* WP (Weather Proof)
XP (Explosion Proof)
Television Outlet Height
Height (indicate nonstandard TV
Clock Receptacle
C Mounting Height)
indicate non-standard
mounting height
Switch
none single pole
Data Communications 2 two pole
Height Height
indicate non-standard 3 three way
S
* WP (Weather Proof)
XP (Explosion Proof) Switch and Single
Receptacle S
dir
Recessed Directional or Down
Lite Low Voltage Halogen
Door-Activated Automatic
Concealed Switch
SA
Ceiling Hung INC. Ornamental Recessed Direction or
Chandlellier Light Fixture Down Lite Low Voltage
Halogen Four Pack Units
Rail or Wire Directional or dir
Down Lite Low Voltage Halogen
Utility & Safety
Service Weatherhead
Meter
* A - Ammeter
* KW - Kilowatt
* KWD - Kilowatt Demand *
* KWH - Kilowatt Hour
* M - Meter
* P - Power
* V - Volt
* VAR - VAR Meter
Battery
Lightning Arrester
Drawout Connection
Flame Detector
Heat Detector
Smoke Detector S
* I - Ionization *
* P - Photoelectric
Gas Detector
* Type *
Sensor
* H - Humidity *
* P - Pressure
* T - Temperature
Pnematic Thermostat T
* A - Aspirating *
* C - Cooling
* D - Day
* D/N - Day Night
* H - Heating
* H/C - Heating/Cooling
* N - Night
Electric Thermostat T
* A - Aspirating *
* C - Cooling
* D - Day
* D/N - Day Night
* H - Heating
* H/C - Heating/Cooling
* N - Night
H
Humidistat
Sensor
* H - Humidity S
* P - Pressure *
* T - Temperature
Wiring
Capacitor Junction Box J
Generator G
Disconnect/Interupt
Y-Connection, Low
or Medium Voltage
Circuit Breaker, 52
Fused Disconnect Medium Voltage
Disconnect/Interrupter
Switch, Medium Voltage
(Indicate Size)
Ground Connection
Pull Station, Fire Alarm F
Buzzer
Rigid Conduit
(Indicate Size & Material)
Buzzer & Bell
Flexible Conduit
Bell
(Indicate Size & Material)
Wiring Neutral
Switch
Wiring Hot