You are on page 1of 4

Fire Alarm Systems | D10024A Analog Fire Alarm Control Panel

D10024A Analog Fire Alarm Control Panel


▶ Up to 630 addressable devices in stand-alone system
▶ Expandable modular design; capable of networking
with other D10024A or D8024 FACPs to create a larger
system
▶ Programmable day-night cycle and device sensitivity
levels for smoke and heat detectors
▶ Program using front control panel keys or PC software
▶ Optional signal line circuit (SLC) isolators, remote
annunciators, and command centers

The D10024A is an advanced analog fire alarm control panel Fire System Controller
(FACP) that identifies points using intelligent, addressable Use the Fire System Controller in the front of the control
devices. On the front of the control panel, light-emitting panel for total system control. Its keypad allows installer
diodes (LEDs) show power, trouble, supervisory, alarm, and and end user programming, event viewing, and device
reset conditions, and the keypad is used for system control control. The D10024A has four keys dedicated to System
and programming. In addition, an 80-character Reset, Alarm Silence, Trouble Silence, and Drill functions.
alphanumeric LCD annunciator provides programmed Active devices are identified through custom text and LEDs
device point information, and four keys are dedicated to that display on the front of the control panel and at the
Reset, Alarm Silence, Trouble Silence, and Drill functions. optional external annunciators.
The D10024A has four onboard notification appliance Indication (Output) Circuits
circuits (NAC) that can be expanded through the use of The D10024A has four on-board circuits for indicating
addressable NAC modules. These circuits can be devices and supports up to 400 programmable and
programmed with specific alarm patterns. addressable remote output circuits for auxiliary control.
These circuits can be programmed for specific alarm
patterns and timed output.
Functions Networking
Event Activity Log Each D10024A has five expansion slots for plug-in polling
The FACP stores up to 500 events in its memory log; circuit modules (D9067). Each module supports 126 analog
recording the time, date, event, and point ID for each event. addressable devices, giving the FACP up to 630 addresses
Events include alarm, system restoral, trouble status, and in a stand-alone system. To simplify system operation,
system status events. The events stored in memory can be flexible system design allows device points to be grouped
retrieved and displayed at the front panel LCD display. In together and identified as one location or zone. Up to four
addition, an 80-character alphanumeric LCD annunciator FACPs can be connected in a shared zone network with up
shows programmed device point information. to 2520 addressable points in 100 zones. Nine
independently‑operating FACPs can report to a dedicated
master FACP in a report and control network.

www.boschsecurity.com
2 | D10024A Analog Fire Alarm Control Panel

Programmable Sensitivity Levels Category Product ID Product Description


The day-night sensitivity program increases the sensitivity
D9078 LED driver module
level during periods of low occupancy. This increases
Programming D5070 Analog device programmer
security and reduces the likelihood of alarm errors.
Products D9060 Programming software and interface
User Levels module
The FACP has three user levels for operation and control. D9061 Graphics software
At all three levels, the LCD display indicates the FACP's
Transmission D9068 Digital alarm communicator transmitter
condition, the Zone LED display indicates the location of Products (DACT)
alarms and troubles, and the alphanumeric display presents
detailed information on alarms and troubles.
Technical Specifications

Certifications and Approvals Auxiliary Contacts (auxiliary terminal)

Contacts: Two on-board, Form C


Region Certification Rating: 250 VAC maximum per relay programmed as A/T
USA UL UOJZ: Control Units, System (UL864) Displays
CSFM 7165-1615: 186
LCD: Two-line by 40-character, back-lit
LED: 10 LED system indicators;
20 LED zone indicators for fire and trouble, expandable to 40 or
Installation/Configuration Notes 80
Compatibility Information Environmental Considerations
The following products are compatible with the D10024A
Analog Fire Alarm Control Panel: Relative Humidity: Up to 85%, non-condensing
Temperature (operating): +32°F to +120°F (0°C to +49°C)
Category Product ID Product Description
History Buffer/Event Log
Detectors D322A Analog heat detector head
D323A Analog photoelectric smoke detector Available Storage: Stores up to 500 events
head Retrieval: Events can be retrieved and displayed at FACP
D324A Analog ionization smoke detector head
Indicating Circuits
D331A Analog duct smoke detector
D332A Analog duct smoke detector Circuits: Four programmable, supervised; Supports up to 400
programmable and addressable remote output circuits
Detector D321A Analog detector base for auxiliary control
Bases D336A Analog detector base Current (total): 2 A; 1 A maximum per output
Keypads and D9069B Fire system annunciator
Keypads
Annunciators D9070B Fire system controller
Manual Stations FMM-325A Analog addressable manual station Description: Alphanumeric, 21-key keypad
Modules D326A Point contact monitoring module Type: Membrane with snap dome
D327A Addressable indicating circuit module Mechanical Properties
D328A Addressable relay module
Color: Off-white
D333A Short circuit isolator
Dimensions (HxWxD): 20 in. x 16 in. x 6.125 in.
D334A Point contact monitoring module
(51 cm x 41 cm x 17 cm)
D339A Point contact monitoring module
Material: Steel
D9051 RS-485 bus module
Weight: 75 lb (34 kg) with batteries
D9052 RS-232 bus module
Zones: Supports up to 80 software zones
D9054-20 LED expansion module, 20 zone
Power Requirements
D9054-60 LED expansion module, 60 zone
D9067 Analog polling circuit module Current (operating): 325 mA
D9069B Remote LCD display module Voltage (operating): 24 VDC nominal at 3 A
D9073 RS-485 bus module, high-integrity, Voltage (primary input): 120 VAC
Class A (non-UL)
D10024A Analog Fire Alarm Control Panel | 3

Sensor Circuit

Addressable Points: Supports up to 630


Circuit Protection: On-board short circuit protection (without isola-
tors in circuit)
Number of Devices: 126 per circuit maximum; Five circuits maximum
Polling Circuits: 30 mA (circuit + sensor load)
Sensor Current: 150 mA typical

Ordering Information
D10024A Analog Fire Alarm Control Panel D10024A
Up to 630 analog-addressable devices; ex-
pandable modular design
Accessories
D9082 Glass Door Kit D9082
For use with the D10024A FACP. Includes two
clear plastic panels, mounting hardware, and
ground strap.

www.boschsecurity.com
4 | D10024A Analog Fire Alarm Control Panel

Americas: Europe, Middle East, Africa: Asia-Pacific: Represented by


Bosch Security Systems, Inc. Bosch Security Systems B.V. Robert Bosch (SEA) Pte Ltd, Security Systems
130 Perinton Parkway P.O. Box 80002 11 Bishan Street 21
Fairport, New York, 14450, USA 5600 JB Eindhoven, The Netherlands Singapore 573943
Phone: +1 800 289 0096 Phone: + 31 40 2577 284 Phone: +65 6258 5511
Fax: +1 585 223 9180 Fax: +31 40 2577 330 Fax: +65 6571 2698
security.sales@us.bosch.com emea.securitysystems@bosch.com apr.securitysystems@bosch.com
www.boschsecurity.us www.boschsecurity.com www.boschsecurity.com

© Bosch Security Systems Inc. 2010 | Data subject to change without notice
T1114285963 | Cur: en-US, V5, 4 Jul 2010