3. Siphon Vortex
WATER CLOSET This type of bowl develops its flushing
Water Closet is a plumbing fixture used to action through the water entering the
receive human excrement & to discharge it diagonal holes around the rim which
through a waste pipe, using water as a creates a swirling action which forms a
conveying medium. vortex in the center.
MINIMUM DRAINAGE
TRAP & FIXTURE
1. Flush Tank FIXTURE
TRAP ARM UNIT
It holds a supply of water for flushing the SIZE (mm) (DFU)
water closet. It flushes 3 to 6 liters. WATER
CLOSET,*
76 mm 4 DFU
2. Flushometer Valve PRIVATE
It is a valve designed to supply a fixed INSTALLATION
quantity of water for flushing purposes. It WATER
is activated by direct water pressure CLOSET,
76 mm 6 DFU
without the use of a flush tank. It requires PUBLIC
INSTALLATION
a flow pressure of 69 to 138 kPa (10 to 20
psi).
WATER SUPPLY
LAVATORY
SHOWER BATH
A Lavatory is a fixture designed for the
A Shower Bath is an apparatus for spraying
washing of the hands or face. It is also
water on the body, usually from above.
known as a Wash Basin.
Drain is through the shower bath floor
The 4 types of Lavatory are:
drain.
1. Wall Hung Lavatory
2. Pedestal Lavatory SHOWER COMPARTMENT - Sec. 409.4
3. Counter Type Lavatory All shower compartments, regardless of
a. Overcounter or Counter top shape, shall have a minimum finished
b. Undercounter interior area of 0.6 square meter, and shall
4. One-piece Lavatory also be capable of encompassing a 762 mm
WASH BASIN/LAVATORY diameter circle. The minimum area and
dimension shall be maintained from a
DRAINAGE point above the shower drain outlet to a
height of 1.78 meters with no protrusions
MINIMUM
DRAINAGE other than the fixture valve or valves,
TRAP &
FIXTURE FIXTURE shower head and safety grab bars or rails.
TRAP ARM
UNIT (DFU)
SIZE (mm)
WASH BATHTUB/SHOWER
BASIN
32 mm 1 DFU DRAINAGE
(LAVATORY)
SINGLE
WASH MINIMUM DRAINAGE
BASIN, 38 mm 2 DFU TRAP & FIXTURE
FIXTURE
IN SETS TRAP ARM UNIT (DFU)
SIZE (mm)
BATHTUBS 38 mm 2 DFU
WATER SUPPLY SHOWER,
SINGLE 51 mm 2 DFU
WATER WATER STALL
SUPPLY SUPPLY SHOWER,
FIXTURE FIXTURE FIXTURE gang
UNIT UNIT 51 mm 2 DFU
(1 unit per
(WSFU): (WSFU): head)
BIDET
KITCHEN SINK
A Bidet is a plumbing fixture used for
A Kitchen Sink is a plumbing fixture washing the middle part of the body,
consisting of a basin with a water supply, especially the genitals. It is also known as
connected with a drain & used for Sitz Bath.
dishwashing. Bidet is used in tandem with the one-piece
water closet or in integrated with the close
Types: coupled water closet.
1. Double Bowl – Single Drain
2. Double Bowl – Double Drain
3. Single Bowl – Single Drain BIDET
4. Corner Sink
5. Triple Bowl DRAINAGE
MINIMUM
DRAINAGE
TRAP &
KITCHEN SINK/SINK FIXTURE FIXTURE
TRAP ARM
UNIT (DFU)
SIZE (mm)
DRAINAGE
BIDET 38 mm 2 DFU
MINIMUM
DRAINAGE
TRAP & WATER SUPPLY
FIXTURE FIXTURE
TRAP ARM
UNIT (DFU)
SIZE (mm) WATER WATER
SINK, SUPPLY SUPPLY
Residential 38 mm 2 DFU FIXTURE FIXTURE
UNIT UNIT
SINK, bar, FIXTURE (WSFU): (WSFU):
38 mm 1 DFU
private PRIVATE PUBLIC
SINK, USE USE
service
51 mm 3 DFU
or mop
basin BIDET 2 WSFU 4 WSFU
A Urinal is a plumbing fixture equipped A deep wide sink used for washing clothes.
with a water supply and drain for flushing
away urine.
SCRUB SINK
The types of Urinals are:
1. Wall Hung Urinal A Scrub Sink is a plumbing fixture usually
located in the O.R. in a hospital to enable
2. Pedestal Urinal
personnel to scrub their hands prior to a
3. Stall Urinal
surgical procedure. The Hot & Cold water
4. Trough Urinal
supply is activated by a knee – action
mixing valve or by wrist or pedal control
URINAL or by automatic sensors.
DRAINAGE
WATER SUPPLY
SHOWER RECEPTORS
WATER WATER
SUPPLY SUPPLY 409.2
FIXTURE FIXTURE Shower receptors are plumbing fixtures.
UNIT UNIT 409.3
FIXTURE (WSFU): (WSFU): Each shower receptor shall be an
PRIVATE PUBLIC approved type and be constructed to have
USE USE a finish dam, curb or threshold which is at
least 25.4 mm lower than the outside floor
URINAL (wall) ------------- 5 WSFU at the sides and back of such receptor. In
no case shall any dam or threshold be less
than 51 mm nor more than 228 mm in
SLOP SINK depth when measured from the top of the
dam or threshold to the drain. The finished
A deep sink, set low & used by janitors for floor of the receptor shall slope uniformly
emptying pails of dirty water & mop from the sides towards the drain not less
cleaning. than 2% or 20mm/m or more than 4% or
OTHER KEYWORDS:
A. PLUMBING
B. PLUMBING SYSTEM
C. MASTER PLUMBER
D. PLUMBING FIRM
E. PLUMBING OFFICIAL
F. PLUMBING CODE
C. MASTER PLUMBER
F. PLUMBING CODE