Servicemanual Cooling units
Design
Cooling units
1 Design
– The cooling elements are designed as fin coolers and combined into cooling units.
– The cooler for the energy recuperation cylinder (ERC) 9520 and the gear oil cooler for pumps and
distributor gear unit 3570 is located on the side of hydraulic oil cooler 3170.
– The condenser 1190 and the cooling water cooler 1110 is attached to switch cabinet 300.
050.010.1
Tuesday, 22.December 2020 15:16 printed this protected document! LH150EC_en.pdf noviana.erhan
copyright by
Cooling units Servicemanual
Function
2 Function
LHB/en/Edition: 10/2017
050.010.2
Tuesday, 22.December 2020 15:16 printedcopyright
this protected
by
document! LH150EC_en.pdf noviana.erhan
Servicemanual Cooling units
Function
– To cool the switch cabinet 300, the coolant (water with anti-freeze and corrosion protection agent)
flows through channels and lines of electrical cabinet.
– It is pumped by the coolant pump 500 through these channels and lines. The water pump 500 is
above the electrical cabinet and runs once the ignition is switched on.
– The THD transformer, inverted rectifier and rectifier are cooled in the electric cabinet and
monitored by three sensors.
– If the temperature of the cooling water rises over 10 °C, fan 1200 is turned on.
2000 Pumps and distributor gear unit 3570 Pumps and distributor gear unit
3170 Hydraulic oil cooler HE Hydraulic oil inlet
3540 Bypass valve HA Hydraulic oil outlet
– Oil in the pumps and distributor gear unit is transported with the aid of an integrated oil pump to
LHB/en/Edition: 10/2017
050.010.3
Tuesday, 22.December 2020 15:16 printed this protected document! LH150EC_en.pdf noviana.erhan
copyright by
Cooling units Servicemanual
Function
LHB/en/Edition: 10/2017
050.010.4
Tuesday, 22.December 2020 15:16 printedcopyright
this protected
by
document! LH150EC_en.pdf noviana.erhan
Servicemanual Cooling units
Function
– Via connections K on the control valve blocks 5100 and 5200, the hydraulic oil is passed to the
hydraulic oil cooler 3170 for cooling.
– There, heat from the hydraulic oil is dissipated in the hydraulic oil cooler before it flows back to the
hydraulic tank 1500.
– In case of an increasing volumetric flow rate (increased hydraulic oil return quantity) in the control
valve blocks 5100 and 5200, the pressure of hydraulic oil increases.
– As a result, the preload valves installed in the control valve blocks open.
– The hydraulic oil thus flows over the connections T on the control valve blocks directly to the
hydraulic tank 1500 to prevent backflow of hydraulic oil.
Note!
For more information on the preload valves, see Chapter 080 in the service manual.
LHB/en/Edition: 10/2017
050.010.5
Tuesday, 22.December 2020 15:16 printed this protected document! LH150EC_en.pdf noviana.erhan
copyright by
Cooling units Servicemanual
Function
LHB/en/Edition: 10/2017
050.010.6
Tuesday, 22.December 2020 15:16 printedcopyright
this protected
by
document! LH150EC_en.pdf noviana.erhan
Servicemanual Cooling units
Maintenance
– To keep the nitrogen in the energy recuperation cylinder in an operating temperature range
between 50 °C and 55 °C, the energy recuperation cylinder must be cooled or heated.
– The coolant is pumped through the heat exchanger on the energy recuperation cylinder.
– Depending on the temperature, the cylinder is either heated by water heater 150 or cooled by
radiator 9520.
– The cooling is controlled by the thermostat attached to the valve unit 9510.
Note!
For more information on the energy recuperation cylinder, see Chapter 080 in the service manual
3 Maintenance
Note!
The procedure and intervals for maintenance of cooling system can be found in the maintenance
and inspection schedule found in the maintenance manual.
LHB/en/Edition: 10/2017
050.010.7
Tuesday, 22.December 2020 15:16 printed this protected document! LH150EC_en.pdf noviana.erhan
copyright by
Cooling units Servicemanual
Maintenance
LHB/en/Edition: 10/2017
050.010.8
Tuesday, 22.December 2020 15:16 printedcopyright
this protected
by
document! LH150EC_en.pdf noviana.erhan
Servicemanual Fan drive
Design
Fan drive
1 Design
– One fan unit consists of a fan wheel 3151, which is connected to the fan motor 3160 by the hub 30.
– The fan wheel 3151 reaches into the cooler box 3159. The finger protection 80 protects against
injuries from the rotating fan wheel 3151. The fan unit 3153 is mounted to the cooler box with the
fan bracket 3159.
LHB/en/Edition: 12/2017
050.022.1
Tuesday, 22.December 2020 15:16 printed this protected document! LH150EC_en.pdf noviana.erhan
copyright by
Fan drive Servicemanual
Function
2 Function
050.022.2
Tuesday, 22.December 2020 15:16 printedcopyright
this protected
by
document! LH150EC_en.pdf noviana.erhan
Servicemanual Fan drive
Adjustment
– The hydraulic fan drive limits the maximum operating temperature of various operating media. The
fan drive is thermostatically monitored and electronically controlled.
– The fan drive cools the following operating media, such as hydraulic oil, gear oil of the pumps and
distributor gear unit and the coolant of the energy recuperation cylinder.
– Each operating medium flows through the fins of separate cooling elements in the cooling unit.
– The fan drive generates an air flow through the fins. The cooling rate of operating medium
therefore depends on fan speed and ambient temperature.
– Depending on the hydraulic temperature, the speed of the fan motor 3160 is controlled
proportionally via the proportional solenoid valve Y602.
– Between minimum and maximum values, the control current of proportional solenoid valve Y602
behaves linearly.
– Each intermediate temperature corresponds to a specific current and pressure. This corresponds
to a specific fan speed. The control mechanism opens / closes the proportional solenoid valve
Y602.
– The more the proportional solenoid valve Y602 is opened, the less hydraulic oil flows to the rotary
group 3261 and the lower the fan speed.
– The excess volume of the rotary group 3161 returns to the hydraulic tank.
3 Adjustment
Note!
For the setting of fan drive, see adjustment in Chapter 030.
4 Maintenance
Note!
The procedure and intervals for maintenance of cooling system can be found in the maintenance
and inspection schedule found in the maintenance manual.
LHB/en/Edition: 12/2017
050.022.3
Tuesday, 22.December 2020 15:16 printed this protected document! LH150EC_en.pdf noviana.erhan
copyright by
Fan drive Servicemanual
Maintenance
LHB/en/Edition: 12/2017
050.022.4
Tuesday, 22.December 2020 15:16 printedcopyright
this protected
by
document! LH150EC_en.pdf noviana.erhan
Servicemanual Reversible fan drive
Design
1 Design
3160 Motor unit, fan 1 3180 Valve block / reverse fan drive fan 1
LHB/en/Edition: 12/2017
050.030.1
Tuesday, 22.December 2020 15:16 printed this protected document! LH150EC_en.pdf noviana.erhan
copyright by
Reversible fan drive Servicemanual
Function
Valve block 3180 is bolted on the bottom of the cooler of the revolving deck.
Engine unit fan 3160 is connected at connection A and connection B of valve block / reverse fan drive
3180.
In valve block 3180, the solenoid valves Y621 and Y622 are installed.
2 Function
– With the optional additional function “reversible fan drive”, the direction of rotation of fan can be
switched (reversed).
– The opposite direction of rotation causes a flow of air to be reversed, cleaning the radiator of dust
and dirt.
LHB/en/Edition: 12/2017
050.030.2
Tuesday, 22.December 2020 15:16 printedcopyright
this protected
by
document! LH150EC_en.pdf noviana.erhan
Servicemanual Reversible fan drive
Function
050.030.3
Tuesday, 22.December 2020 15:16 printed this protected document! LH150EC_en.pdf noviana.erhan
copyright by
Reversible fan drive Servicemanual
Function
Note!
The function of fan 1 is described below.
– Proportional solenoid valve / fan Y602 is energised. Fan pump 3100 transports hydraulic oil
quantity for fan speed in reverse operation.
– By switching solenoid valves Y621 and Y622, the circuits are separated again. The hydraulic oil
flows in opposite direction.
– Hydraulic oil from connection P flows through switched solenoid valve Y622 to connection B.
– Hydraulic oil from connection P flows in the circuit of solenoid valve Y622 through solenoid valve
Y621 back to solenoid valve Y622.
– Hydraulic oil from connection A flows through solenoid valve Y622 to connection T.
050.030.4
Tuesday, 22.December 2020 15:16 printedcopyright
this protected
by
document! LH150EC_en.pdf noviana.erhan
Servicemanual Reversible fan drive
Function
– Hydraulic oil from connection A flows in the circuit of solenoid valve Y622 through solenoid valve
Y621 back to solenoid valve Y622.
– Fan rotates in opposite direction.
050.030.5
Tuesday, 22.December 2020 15:16 printed this protected document! LH150EC_en.pdf noviana.erhan
copyright by
Reversible fan drive Servicemanual
Adjustment
3 Adjustment
For the setting of fan drive and reversal, see adjustment procedure in Chapter 030.
4 Maintenance
LHB/en/Edition: 12/2017
050.030.6
Tuesday, 22.December 2020 15:16 printedcopyright
this protected
by
document! LH150EC_en.pdf noviana.erhan