FLAME DETECTORS:
1
2
EXHAUST PLENUM:
B
A
7
6 8 9
LEGEND:
110 12
10
LEGEND:
14
13
LEGEND:
13 : HV200 valve [NO]: Installed in the AD-2 line supplying compressor discharge air to false start drain
valves (VA17-1 & VA17-2).
: HV400 valve [NO]: Installed in the AD-4 line supplying compressor discharge air to the pressure
14
transducers (96CD-1A, 96CD-1B & 96CD-1C).
15
15 : BV120 valve [NO]: Installed in the AD-1 line supplying Compressor Discharge air to 20CB-1 for
bleed valves control.
16
17
16 : BV300 valve (NO): Installed in the AD-3 line supplying compressor discharge air (CA5) to Air
Processing Unit (APU) or self cleaning inlet air filter.
18
18 : BV110 valve [NO]: Installed in Compressor stage 11 (AE-11) bearing sealing air supply line.
19
19 : BV100 valve [NO]: installed in Compressor stage 5 (AE-5) bearing sealing air supply line.
20
20 : BV102 valve [NC]: Bearing sealing air separator drain valve (also called blow down valve).
AE-5 piping low point drain
21
21 : BV101 valve [NC]: Low point drain valve on bearing sealing air line (AE-5 piping low point drain).
22
23
22 : VM15-1 Isolation valve: Inlet Bleed Heat (IBH) manual isolation valve.
PEECC:
24. 20TW-1 Offline wash breaker in 240V cubicle in the PEECC.
25. 88TK-1 and 88TK-2 to be manually switched “ON” during the water wash start-up Operation (i.e.
if there don’t come in automatically).