COMPRESSOR WATER WASH ISOLATION

FLAME DETECTORS:

1
2

1 : Flame detector cooling water isolation valve

2 : Flame detector cooling water isolation valve

EXHAUST PLENUM:

3 4 5 : Main Water Wash Drain Valves [NC]


INLET PLENUM:

B
A
7

6 8 9

LEGEND:

A : 20TW-1 [OFFLINE WASH]

B : 20TW-3 [ONLINE WASH]

6 : Drain valve adjacent to the inlet plenum drain valve [NC]

7 : Inlet plenum drain valve (BV140) [NC]

8 : Drain valve (HV120) after 20TW-1 [NC]

9 : Manual Isolation Valve before 20TW-1 [NC]

NC: Normally close valve


AUXILIARIES COMPARTMENT:

110 12

10

LEGEND:

10 : 96CD-1A Isolating valve (HV401) [NO]

11 : 96CD-1B Isolating valve (HV403) [NO]

12 : 96CD-1C Isolating valve (HV405) [NO]

NO: Normally open valve


TURBINE COMPARTMENT

14
13

LEGEND:

13 : HV200 valve [NO]: Installed in the AD-2 line supplying compressor discharge air to false start drain
valves (VA17-1 & VA17-2).

: HV400 valve [NO]: Installed in the AD-4 line supplying compressor discharge air to the pressure
14
transducers (96CD-1A, 96CD-1B & 96CD-1C).

15

15 : BV120 valve [NO]: Installed in the AD-1 line supplying Compressor Discharge air to 20CB-1 for
bleed valves control.
16

17

16 : BV300 valve (NO): Installed in the AD-3 line supplying compressor discharge air (CA5) to Air
Processing Unit (APU) or self cleaning inlet air filter.

17 : Compressor discharge casing low point drain valve.

18

18 : BV110 valve [NO]: Installed in Compressor stage 11 (AE-11) bearing sealing air supply line.
19

A : Bearing sealing air dirt Separator

19 : BV100 valve [NO]: installed in Compressor stage 5 (AE-5) bearing sealing air supply line.

20

20 : BV102 valve [NC]: Bearing sealing air separator drain valve (also called blow down valve).
AE-5 piping low point drain

21

21 : BV101 valve [NC]: Low point drain valve on bearing sealing air line (AE-5 piping low point drain).
22

23

22 : VM15-1 Isolation valve: Inlet Bleed Heat (IBH) manual isolation valve.

23 : VM15-1 Motorized by-pass valve.

*low point drains on inlet heating system if provided.

*low point drains on AD-3 line if provided.

PEECC:
24. 20TW-1 Offline wash breaker in 240V cubicle in the PEECC.

25. 88TK-1 and 88TK-2 to be manually switched “ON” during the water wash start-up Operation (i.e.
if there don’t come in automatically).