You are on page 1of 8

1/6/22, 3:23 PM Induction Heater

Oscilloscope Tracings HOT

Search

The inverter outputs a drive voltage to the coupling transformer. The current in is in
phase with the current out. When the tank is at resonance, the tank current is in ₹249
phase with the drive current of the coupling transformer, and is in phase with the
inverter input voltage. If anything, you want the current to slightly lag the voltage HOT
because the mosfets behave better when facing an inductive, rather than a
capacitive, load. This has to do with the mosfets conducting in the reverse direction.
The tracing below is clean and allows me to reach very high power levels while
maintaining relatively cool mosfets.
₹395

HOT

₹63

₹1,375

ElectronicsComp.com

inductionheatertutorial.com/inductionheater/induction6.html 1/8
1/6/22, 3:23 PM Induction Heater

Now, if the tanks is above resonance we have more inductive reactance. The tank's net current will lag the
driving voltage from the coupling transformer. Since the input and output current of the coupling transformer
are in phase, the tank's current is lagging the inverter driving voltage. Below you can see the dominating
inductive reactance results in the inverter current (triangle-looking wave) is almost 90 degrees lagging the
inverter voltage (square wave).

inductionheatertutorial.com/inductionheater/induction6.html 2/8
1/6/22, 3:23 PM Induction Heater

ElectronicsComp.com

inductionheatertutorial.com/inductionheater/induction6.html 3/8
1/6/22, 3:23 PM Induction Heater

If we are below the resonant frequency capacitive reactance results in the current leading the inverter voltage.
Also, there is ringing in the current waveform and at the inverter voltage transitions. This noise gets worse
with higher power levels and can result in mosfet failure.

inductionheatertutorial.com/inductionheater/induction6.html 4/8
1/6/22, 3:23 PM Induction Heater

Below is another example of ringing. You can see ringing on the voltage at the transition and on the current
waveform. I have positioned them apart for easier viewing. This is due to high inductance on the gate. Heavy
current on the gate causes a large Ldi/dt. The problem can usually be solved by either increasing the gate
resistance (increase the resistor value), or decrease the stray inductance by shortening the gate lead. I was
able to almost eliminate the ringing by shortening the gate lead, but then I did not have enough length for
connecting two in parallel. So I changed the value of R from 5 ohms to 10 ohms. The first image is with the 5
ohm gate resistor. I was still able to charge the gate with 10 ohms in a sufficiently short amount of time at
15v.

inductionheatertutorial.com/inductionheater/induction6.html 5/8
1/6/22, 3:23 PM Induction Heater

These images show the waveform after the fix: shortening the gate leads as much as possible to still allow
room for paralleling two of them and increasing the gate resistor from 5R to 10R. Notice the clean voltage
square wave and the smooth current curve. The second image is a blow-up of the first.

inductionheatertutorial.com/inductionheater/induction6.html 6/8
1/6/22, 3:23 PM Induction Heater

Below is a basic sketch of the half-bridge inverter. The coil in the middle is the coupling transformer to the
resonant tank. The arrows show the paths the current takes as the switches alternate between closed-open and
open-closed.

Below are two sketches. Sketch I shows ringing if there is too long of a delay during switching. If the next
switch does not close in time, the inductive kick will drive the voltage too high, causing an overshoot,
followed by a large dip when it finally closes. Sketch II shows profound voltage sagging in the middle of the
waveform. I had this happen when the decoupling capacitors went bad, shorting the current path. The
capacitors are needed to remove any DC component from the pulse.

I would like just mention that the inductive waveforms is really an exponential curve. If we can approximate
the tank above resonane as a RL circuit responding to a step response

The solution to

inductionheatertutorial.com/inductionheater/induction6.html 7/8
1/6/22, 3:23 PM Induction Heater

is

Analysis of a capacitor dominant RC circuit will yield something similar. When dealing with a RCL step
response one has

and the 2nd order differential equation is

and the general solution is

If the system is underdamped the solution has the form:

V(t) = e-αt(Bcos(ѡt) + Bsin(ѡt))

Next Page