You are on page 1of 72

KS SERIES - VERTICAL INSTALLATION

CI-DS-01-KSV C & I DISCLAIMER


REVISION
CI-PP-01-KSV PANEL PROFILES
0 1/01/21
CI-PP-02-KSV PANEL PROFILES 1 1/27/21
CI-FP-01-KSV FASTENING PATTERNS 2 2/03/21
3 3/03/21
CI-FP-02-KSV FASTENING PATTERNS
CI-FP-03-KSV FASTENING PATTERNS
CI-PJ-01-KSV EXPANDED PANEL JOINT
CI-PJ-02-KSV ENGAGED PANEL JOINT
CI-PJ-03-KSV INTERMEDIATE SUPPORT
CI-BS-01-KSV FLUSH BASE
CI-BS-02-KSV FLUSH BASE 2
CI-BS-03-KSV BASE AT NOTCHED CONCRETE
CI-BS-04-KSV OVERHANG WITH BASE SUPPORT
CI-BS-05-KSV OVERHANG WITH BASE ANGLE
CI-BS-06-KSV OVERHANG W/ BASE "J" EXTRUSION
CI-BS-07-KSV BASE DETAIL MARRIAGE BEAD ISOMETRIC
CI-OC-01-KSV OUTSIDE CORNER WITH PROFILED TRIM
CI-OC-02-KSV OUTSIDE CORNER WITH FLAT TRIM
CI-OC-03-KSV OUTSIDE CORNER WITH EXTRUSION
CI-IC-01-KSV INSIDE CORNER WITH PROFILED TRIM
CI-IC-02-KSV INSIDE CORNER WITH FLAT TRIM
CI-IC-03-KSV INSIDE CORNER WITH EXTRUSION
CI-IC-04-KSV TRIM LAP AT I.C. BASE EXPANDED
CI-IC-05-KSV TRIM LAP AT I.C. BASE ENGAGED
CI-IC-06-KSV INSIDE CORNER TRIM LAP EXPANDED
CI-IC-07-KSV INSIDE CORNER TRIM LAP ENGAGED
CI-FO-01-KSV F.O. TWO PIECE HEAD
CI-FO-02-KSV F.O. HEAD WITH DRIP EDGE
CI-FO-03-KSV F.O. TWO PIECE JAMB
CI-FO-04-KSV F.O. ONE PIECE JAMB
CI-FO-05-KSV F.O. ONE PIECE SILL
CI-FO-06-KSV F.O. INTERIOR PARTITION
CI-FO-07-KSV O.H. DOOR TWO PIECE HEAD

DETAIL #: XX-XX-XX-KSV
INDEX SHEET 1
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
CI-FO-08-KSV O.H. DOOR HEAD WITH DRIP EDGE
CI-FO-9-KSV O.H. DOOR TWO PIECE JAMB
CI-FO-10-KSV HEADER WITH EXTRUSION
CI-FO-11-KSV JAMB WITH EXTRUSION
CI-FO-12-KSV SILL WITH EXTRUSION
CI-FO-13-KSV O.H. DOOR WITH EXTRUSION
CI-FO-14-KSV O.H. DOOR JAMB WITH EXTRUSION
CI-SJ-01-KSV STACK JOINT
CI-SJ-02-KSV STACK JOINT WITH EXTRUSION
CI-PR-01-KSV PARAPET WITH FLUSH TRIM
CI-PR-02-KSV PARAPET WITH PROFILED TRIM
CI-SO-01-KSV WALL ABOVE TO HORIZONTAL SOFFIT
CI-SO-02-KSV WALL BELOW TO HORIZONTAL SOFFIT
CI-SO-03-KSV WALL ABOVE TO VERTICAL SOFFIT
CI-SO-04-KSV WALL BELOW TO VERTICAL SOFFIT
CI-WR-01-KSV WALL TO ROOF
CI-WR-02-KSV CONTINUOUS WALL TO ROOF / CANOPY
CI-PE-01-KSV PIPE PENETRATION
CI-PE-02-KSV PIPE PENETRATION ISOMETRIC
CI-PE-03-KSV KNIFE PENETRATION
CI-PE-04-KSV KNIFE PENETRATION ISOMETRIC
CI-PE-05-KSV BEAM PENETRATION
CI-PE-06-KSV BEAM PENETRATION ISOMETRIC
CI-TL-01-KSV TRIM END LAP
CI-TL-02-KSV TRIM END LAP WITH HEM
CI-TL-03-KSV TRIM END LAP WITH LAP STRIP
CI-TL-04-KSV TRIM LAP AT F.O.
CI-TL-05-KSV TRIM LAP AT F.O. INSTALLATION
CI-TL-06-KSV OPTIONAL FLEX WRAP AT F.O. INSTALLATION
CI-TL-07-KSV 2" EXTRUSIONS

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: XX-XX-XX-KSV
INDEX SHEET 2
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

CI-TL-08-KSV 212" EXTRUSIONS


CI-TL-09-KSV 3" EXTRUSIONS
CI-TL-10-KSV 4" EXTRUSIONS
CI-TL-11-KSV EXTRUSION LAP STRIPS
CI-TL-12-KSV EXTRUSION AT F.O.

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: XX-XX-XX-KSV
INDEX SHEET 3
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

DISCLAIMERS:

THESE DETAILS ARE PROVIDED AS A GUIDELINE FOR PROPER PANEL AND ASSOCIATED
COMPONENT INSTALLATION, AND ARE BASED ON INDUSTRY ACCEPTED PRACTICES.

LOCATION OF VAPOR BARRIERS AND ASSOCIATED SEALANTS IN THESE DETAILS ARE BASED
ON TYPICAL DESIGN PRACTICES FOR MOST U.S. AND CANADIAN CLIMACTIC ZONES. (THE PRIMARY
VAPOR BARRIER IS PLACED ON THE "WARM" SIDE IN WINTER).

PROJECTS LOCATED IN AREAS SUBJECT TO EXTREME COLD AND/OR HIGH SNOW LOADS MAY
REQUIRE MODIFICATIONS TO THESE DETAILS - CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT RECOMMENDATIONS.

ALL STRUCTURAL SUPPORTS ARE NOT BY KINGSPAN AND ARE SHOWN FOR CLARIFICATION AND
ILLUSTRATION PURPOSES ONLY.

CONTACT KINGSPAN TECHNICAL SERVICES FOR MAXIMUM ALLOWABLE PANEL SPANS


AND FASTENING PATTERNS.

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-DS-01-KSV
COMMERCIAL/INDUSTRIAL
DISCLAIMER RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
EMBOSSING:
CORE DEPTHS: MODULE WIDTH: 24", 30", 36", 42" EXTERIOR: STUCCO / SMOOTH*
2", 2.5", 3", 4", 5", 6" INTERIOR: STUCCO / SMOOTH
PANEL ORIENTATION: VERTICAL
STEEL GAUGES: LENGTHS:
EXTERIOR: (REFER TO PROFILE) MINIMUM: 8'-0"
INTERIOR: 26, 24, 22 MAXIMUM: 53'-0"
SHADOWLINE
INTERIOR FACE MALE JOINT
FEMALE JOINT KS SHADOWLINE (SL) 2" - 6"
EXTERIOR FACE SHADOWLINE
(22GA, 24GA, 26GA) REVEAL
42" COVERAGE (36", 30", & 24" OPTIONAL)
OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS

SHADOWLINE
INTERIOR FACE MALE JOINT
FEMALE JOINT KS MICRO RIB (MR) 2" - 6"
EXTERIOR FACE MICRO-RIB
(24GA, 22GA ONLY) REVEAL

42" COVERAGE (36", 30", & 24" OPTIONAL)


OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS

SHADOWLINE
INTERIOR FACE MALE JOINT
FEMALE JOINT KS MINI-MICRO RIB (MMR) 2" - 6"
EXTERIOR FACE MINI MICRO-RIB
(24GA ONLY)
(*SMOOTH ONLY)
42" COVERAGE (36", 30", & 24" OPTIONAL)
OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS

SHADOWLINE
INTERIOR FACE MALE JOINT
FEMALE JOINT KS AZTECO (AZ) 2" - 6"
EXTERIOR FACE AZTECO
(24GA, 22GA ONLY)
42" COVERAGE (36", 30", & 24" OPTIONAL)
OPTIONAL TRIMLESS ENDS AND FOLDED CORNERS

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-PP-01-KSV
PANEL PROFILES
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
EMBOSSING:
CORE DEPTHS: MODULE WIDTH: 24", 30", 36", 42" EXTERIOR: STUCCO / SMOOTH*
2", 2.5", 3", 4", 5", 6" INTERIOR: STUCCO / SMOOTH
PANEL ORIENTATION: VERTICAL
STEEL GAUGES: LENGTHS:
EXTERIOR: (REFER TO PROFILE) MINIMUM: 8'-0"
INTERIOR: 26, 24, 22 MAXIMUM: 53'-0"
SHADOWLINE
INTERIOR FACE MALE JOINT
FEMALE JOINT KS MINI WAVE (MW) 2" - 6"
EXTERIOR FACE MINI-WAVE
(24GA, 22GA ONLY)
42" COVERAGE (36", 30", & 24" OPTIONAL)

SHADOWLINE
INTERIOR FACE MALE JOINT
FEMALE JOINT KS SL FLAT 2" - 6"
EXTERIOR FACE FLAT
(26GA, 24GA, 22GA)
42" COVERAGE (36", 30", & 24" OPTIONAL)

SHADOWLINE
INTERIOR FACE MALE JOINT
FEMALE JOINT KS GRANITSTONE/QUARTZ (GS) 2" - 6"
EXTERIOR FACE GRANITSTONE / QUARTZ
(24GA, 22GA ONLY)
42" COVERAGE (36", 30", & 24" OPTIONAL)

SHADOWLINE or FLAT
INTERIOR FACE

KS OPTIMO (OPE or OPS) 2" - 4"


EXTERIOR FACE FLAT NOTE:
(22GA ONLY)
40" COVERAGE MAX LENGTH:
(24", 30", 36" OPTIONAL) EMBOSSED: 32'-0"
OPTIONAL TRIMLESS ENDS SMOOTH: 20'-0"

REVISION
REVISION # DATE
0 1/21/21

DETAIL #: CI-PP-02-KSV
PANEL PROFILES
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

STRUCTURAL SUPPORT
(BY OTHERS)
FEMALE MALE
END END
INTERIOR FACE

EXTERIOR FACE

42"

FASTENING PATTERN 1B
STANDARD SIDE JOINT FASTENING WITH 12GA 2-HOLE CLIP AND 1 4"-14 HEX
HEAD FASTENER WITHOUT WASHER

STRUCTURAL SUPPORT
10.5"
(BY OTHERS)
1
4" - 14 "LOW PROFILE"
THROUGH FASTENER W/
FEMALE 1 18" BONDED WASHER MALE
END END
INTERIOR FACE

EXTERIOR FACE

42"

FASTENING PATTERN 2B
STANDARD SIDE JOINT FASTENING WITH 12GA 2-HOLE CLIP AND 1 4"-14 HEX
HEAD FASTENER WITHOUT WASHER / ADDITIONAL 1 4"-14 "LOW PROFILE"
THROUGH FASTENER W/ 1 18" BONDED WASHER 10.5" FROM FEMALE JOINT

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FP-01-KSV
FASTENING PATTERNS
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
1
4" - 14 "LOW PROFILE"
THROUGH FASTENER W/
10.5" 10.5" 1 18" BONDED WASHER
STRUCTURAL SUPPORT
(BY OTHERS)
FEMALE MALE
END END
INTERIOR FACE

EXTERIOR FACE

42"

FASTENING PATTERN 3B
STANDARD SIDE JOINT FASTENING WITH 12GA 2-HOLE CLIP AND 1 4"-14 HEX
HEAD FASTENER WITHOUT WASHER / 2 ADDITIONAL 1 4"-14 "LOW PROFILE"
THROUGH FASTENER W/ 1 18" BONDED WASHER SPACED @ 10.5" FROM
FEMALE JOINT

10.5" 10.5" 10.5"


1
4" - 14 "LOW PROFILE"
STRUCTURAL THROUGH FASTENER W/
SUPPORT 1 18" BONDED WASHER
FEMALE (BY OTHERS)
MALE
END END
INTERIOR FACE

EXTERIOR FACE

42"

FASTENING PATTERN 4B
STANDARD SIDE JOINT FASTENING WITH 12GA 2-HOLE CLIP AND 1 4"-14 HEX
HEAD FASTENER WITHOUT WASHER / 3 ADDITIONAL 1 4"-14 "LOW PROFILE"
THROUGH FASTENER W/ 1 18" BONDED WASHER SPACED @ 10.5" FROM
FEMALE JOINT
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FP-02-KSV
FASTENING PATTERNS
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

8.4" 8.4" 8.4" 8.4"


1
4" - 14 "LOW PROFILE"
STRUCTURAL THROUGH FASTENER W/
SUPPORT 1 18" BONDED WASHER
FEMALE (BY OTHERS)
MALE
END END
INTERIOR FACE

EXTERIOR FACE

42"

FASTENING PATTERN 5B
STANDARD SIDE JOINT FASTENING WITH 12GA 2-HOLE CLIP AND 14"-14 HEX
HEAD FASTENER WITHOUT WASHER / 4 ADDITIONAL 14"-14 "LOW PROFILE"
THROUGH FASTENER W/ 1 18" BONDED WASHER SPACED @ 8.4" FROM
FEMALE JOINT

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FP-03-KSV
FASTENING PATTERNS
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

HORIZONTAL SUPPORT
(NOT BY KINGSPAN)

MALE JOINT FEMALE JOINT

CONTINUOUS
12 GA. STAINLESS STEEL BUTYL SEALANT
HIDDEN FASTENER CLIP
(1 PER PANEL, PER SUPPORT) CONTINUOUS
SET CLIP IN BUTYL SEALANT BUTYL SEALANT
(OPTIONAL)
1
4" - 14 HEX HEAD
FASTENERS WITHOUT WASHER

WALL PANEL INSTALLATION DIRECTION

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-PJ-01-KSV
EXPANDED
PANEL JOINT RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

HORIZONTAL SUPPORT
(NOT BY KINGSPAN)

MALE JOINT FEMALE JOINT

1 "
8
PANEL MODULE CONTINUOUS
BUTYL SEALANT
12 GA. STAINLESS STEEL
HIDDEN FASTENER CLIP CONTINUOUS
(1 PER PANEL, PER SUPPORT) BUTYL SEALANT
SET CLIP IN BUTYL SEALANT (OPTIONAL)
1
4" - 14 HEX HEAD
FASTENERS WITHOUT WASHER

WALL PANEL INSTALLATION DIRECTION

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-PJ-02-KSV
ENGAGED
PANEL JOINT RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

1
4" - 14 HEX HEAD FASTENERS
WITHOUT WASHER
HORIZONTAL SUPPORT
(NOT BY KINGSPAN)

12 GA. STAINLESS STEEL


HIDDEN FASTENER CLIP
(1 PER PANEL, PER SUPPORT)
SET CLIP IN BUTYL SEALANT

1 " 3
2 4 4"
1"

5
16" Ø

STANDARD:
12 GA. STAINLESS STEEL
TWO-HOLE HIDDEN FASTENER CLIP

NOTE:
CONTACT KINGSPAN TECHNICAL SERVICES
FOR SPECIFIC PROJECT RECOMMENDATIONS
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-PJ-03-KSV
INTERMEDIATE
SUPPORT RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
12 GA. STAINLESS STEEL
INSTALLER TO ENSURE THERE
HIDDEN FASTENER CLIP
ARE NO GAPS IN SEALANT
(1 PER PANEL, PER
SUPPORT) 1
SET CLIP IN BUTYL 4" - 14 HEX HEAD

SEALANT FASTENERS WITHOUT WASHER

CONTINUOUS BUTYL SEALANT


BASE TRIM W/ POP
RIVETS @ 8" O.C.

BASE ANGLE W/ MIN. 3" VERT.


LEG FOR PANEL ATTACHMENT,
BASE FLASHING BASE CHANNEL SET IN SEALANT
(NOT BY KINGSPAN)

CONTINUOUS BUTYL
SEALANT BELOW BASE
FASTENER TO CONCRETE
FLASHING
(NOT BY KINGSPAN)

SEALANT MARRIAGE BEAD TO


VERTICAL PANEL JOINT

NOTE: SEE DETAIL CI-TL-01-KSV AND CI-TL-02-KSV FOR TYPICAL


TRIM LAP INSTRUCTIONS

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-BS-01-KSV
FLUSH BASE
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
12 GA. STAINLESS STEEL
INSTALLER TO ENSURE THERE
HIDDEN FASTENER CLIP
ARE NO GAPS IN SEALANT
(1 PER PANEL, PER
SUPPORT) 1
SET CLIP IN BUTYL 4" - 14 HEX HEAD

SEALANT FASTENERS WITHOUT WASHER

BASE TRIM W/ POP CONTINUOUS BUTYL SEALANT


RIVETS @ 8" O.C.

BASE ANGLE W/ MIN. 3" VERT.


LEG FOR PANEL ATTACHMENT,
BASE FLASHING BASE CHANNEL SET IN SEALANT
(NOT BY KINGSPAN)

CONTINUOUS BUTYL
SEALANT BELOW BASE
FASTENER TO CONCRETE
FLASHING
(NOT BY KINGSPAN)

SEALANT MARRIAGE BEAD TO


VERTICAL PANEL JOINT

NOTE: SEE DETAIL CI-TL-01-KSV AND CI-TL-02-KSV FOR TYPICAL


TRIM LAP INSTRUCTIONS

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-BS-02-KSV
FLUSH BASE 2
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

1
12 GA. STAINLESS STEEL 4" - 14 HEX HEAD
HIDDEN FASTENER CLIP FASTENERS WITHOUT WASHER
(1 PER PANEL, PER
CONTINUOUS BUTYL SEALANT W/
SUPPORT)
MARRIAGE BEAD TO VERTICAL
SET CLIP IN BUTYL
PANEL JOINT
SEALANT
BASE ANGLE W/ MIN. 3" VERT.
BASE TRIM W/ POP LEG FOR PANEL ATTACHMENT,
RIVETS @ 8" O.C. BASE CHANNEL SET IN SEALANT
(NOT BY KINGSPAN)

(TYP.)
112"
BASE FLASHING

FASTENER TO CONCRETE
(NOT BY KINGSPAN)
CONTINUOUS BUTYL CONTINUOUS BUTYL SEALANT
SEALANT BELOW BASE
FLASHING

NOTE: SEE DETAIL CI-TL-01-KSV AND CI-TL-02-KSV FOR TYPICAL


TRIM LAP INSTRUCTIONS

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-BS-03-KSV
BASE AT NOTCHED
CONCRETE RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

1
12 GA. STAINLESS STEEL 4" - 14 HEX HEAD
HIDDEN FASTENER CLIP FASTENERS WITHOUT WASHER
(1 PER PANEL, PER
SUPPORT) CONTINUOUS BUTYL SEALANT W/
SET CLIP IN BUTYL MARRIAGE BEAD TO VERTICAL
SEALANT PANEL JOINT
POP RIVETS BASE ANGLE W/ MIN. 3" VERT.
@ 8" O.C. LEG FOR PANEL ATTACHMENT,
BASE CHANNEL SET IN SEALANT
BASE TRIM (NOT BY KINGSPAN)

(TYP.)
112"

FASTENER TO CONCRETE
(NOT BY KINGSPAN)

NOTE: SEE DETAIL CI-TL-01-KSV AND CI-TL-02-KSV FOR TYPICAL


TRIM LAP INSTRUCTIONS

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-BS-04-KSV
OVERHANG WITH
BASE SUPPORT RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

1
4" - 14 HEX HEAD
FASTENERS WITHOUT WASHER

12 GA. STAINLESS STEEL CONTINUOUS BUTYL SEALANT


HIDDEN FASTENER CLIP BOTH SIDES OF TRIM W/
(1 PER PANEL, PER MARRIAGE BEAD TO VERTICAL
SUPPORT) PANEL JOINT
SET CLIP IN BUTYL
SEALANT
BASE ANGLE W/ MIN. 3" VERT.
BASE TRIM W/ LEG FOR PANEL ATTACHMENT,
POP RIVETS @ BASE CHANNEL SET IN SEALANT
8" O.C. (NOT BY KINGSPAN)

(TYP.)
112"

FASTENER TO CONCRETE
(NOT BY KINGSPAN)

NOTE: SEE DETAIL CI-TL-01-KSV AND CI-TL-02-KSV FOR TYPICAL


TRIM LAP INSTRUCTIONS

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-BS-05-KSV
OVERHANG WITH
BASE ANGLE RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
12 GA. STAINLESS STEEL
ARE NO GAPS IN SEALANT
HIDDEN FASTENER CLIP
(1 PER PANEL, PER 1
SUPPORT) 4" - 14 HEX HEAD

SET CLIP IN BUTYL FASTENERS WITHOUT WASHER


SEALANT 1
4" - 14 "LOW PROFILE"
FASTENER
PANEL BASE "B"
EXTRUSION CONTINUOUS BUTYL SEALANT BOTH
SIDES OF EXTRUSION W/ MARRIAGE
BEAD TO VERTICAL PANEL JOINT

BASE ANGLE W/ MIN. 3" VERT.


LEG FOR PANEL ATTACHMENT,
BASE CHANNEL SET IN SEALANT
(NOT BY KINGSPAN)
OPTIONAL WIPER

(TYP.)
GASKET

112"
(FIELD INSTALLED)

FIELD DRILL 3 8"Ø FASTENER TO CONCRETE


WEEP HOLES @ 24"
(NOT BY KINGSPAN)
O.C. AND AT EACH
VERTICAL JOINT
WHEN POSSIBLE
(NOT BY KINGSPAN)

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-BS-06-KSV
OVERHANG WITH
BASE "J" EXTRUSION RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

12 GA. STAINLESS STEEL


HIDDEN FASTENER CLIP
(1 PER PANEL, PER SUPPORT)
SET CLIP IN BUTYL SEALANT

PANEL CLIP TO BE SET IN BED OF BUTYL


SEALANT

MARRIAGE BEAD TO VERTICAL JOINT


(FEMAILE INTERIOR JOINT TO HAVE EITHER
FACTORY OR FIELD CONTINUOUS BUTYL
SEALANT)

BASE ANGLE W/ MIN. 3" VERT.


LEG FOR PANEL ATTACHMENT,
BASE CHANNEL SET IN SEALANT
(NOT BY KINGSPAN)

CONTINUOUS HEAVY BEAD


OF BUTYL SEALANT

BASE FLASHING

NOTE:
ENSURE THERE ARE NO
GAPS IN SEALANT BEAD.
COVERAGE MUST BE
REVISION
CONTINUOUS REVISION # DATE
0 01/01/21

BASE DETAIL DETAIL #: CI-BS-07-KSV


MARRIAGE BEAD
RELEASE: 2021 www.kingspanpanels.us
ISOMETRIC www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

WILL VARY WITH


FIELD CONDITION

FIELD CONDITION
WILL VARY WITH

FIELD CUT

FIELD CUT

CONTINUOUS BUTYL
TAPE / SEALANT

POP RIVETS @ 8" O.C.


PROFILED OUTSIDE
CORNER TRIM

COMPRESSED
MINERAL FIBER
AS REQUIRED
(NOT BY KINGSPAN)
1
4" - 14 THROUGH FASTENERS
W/ 118" BONDED WASHER
(AS REQUIRED FOR WIND LOAD) 3
4" PHIL. PAN HEAD @
8" O.C.
CONTINUOUS BUTYL
ATTACHMENT CLIP
TAPE / SEALANT
(NOT BY KINGSPAN)
INSIDE CORNER TRIM
POP RIVETS @ 8" O.C.
CONTINUOUS
BUTYL SEALANT

HORIZONTAL SUPPORT
(NOT BY KINGSPAN)

REVISION
REVISION # DATE
1 1/27/21

DETAIL #: CI-OC-01-KSV
OUTSIDE CORNER
WITH PROFILED TRIM RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

WILL VARY WITH


FIELD CONDITION

FIELD CONDITION
WILL VARY WITH

FIELD CUT

CONTINUOUS BUTYL
TAPE / SEALANT

POP RIVETS @ 8" O.C.


OUTSIDE CORNER TRIM

COMPRESSED
MINERAL FIBER
AS REQUIRED
(NOT BY KINGSPAN)
1
4" - 14 "LOW PROFILE"
THROUGH FASTENER WITH
118" BONDED WASHER (AS 3
REQUIRED FOR WIND LOAD) 4" PHIL. PAN HEAD @
8" O.C.
ATTACHMENT CLIP
CONTINUOUS BUTYL (NOT BY KINGSPAN)
TAPE / SEALANT INSIDE CORNER TRIM

CONTINUOUS
POP RIVETS @ 8" O.C. BUTYL SEALANT

HORIZONTAL SUPPORT
(NOT BY KINGSPAN)

REVISION
REVISION # DATE
1 1/27/21

DETAIL #: CI-OC-02-KSV
OUTSIDE CORNER
WITH FLAT TRIM RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

WILL VARY WITH


FIELD CONDITION

FIELD CONDITION
WILL VARY WITH

FIELD CUT

1
4" - 14 "LOW PROFILE"
THROUGH FASTENER WITH
118" BONDED WASHER (AS
CORNER EXTRUSION MALE
REQUIRED FOR WIND LOAD)

OPTIONAL WIPER
GASKET
(FIELD INSTALLED)

COMPRESSED
MINERAL FIBER 1
4" - 14 "LOW PROFILE"
AS REQUIRED
FASTENER
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
SEALANT

CORNER EXTRUSION
FEMALE

VERTICAL SUPPORT
(NOT BY KINGSPAN)

REVISION
REVISION # DATE
1 1/27/21

DETAIL #: CI-OC-03-KSV
OUTSIDE CORNER
W/ EXTRUSION RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD CONDITION
WILL VARY WITH

FIELD CUT

CONTINUOUS BUTYL SEALANT

3
4" PHIL. PAN HEAD @ 8" O.C.
OUTSIDE CORNER TRIM

FILL ALL VOIDS WITH


COMPRESSED MINERAL
FIBER AS
REQUIRED
(NOT BY KINGSPAN)

CONTINUOUS
BUTYL SEALANT
CONTINUOUS BUTYL
TAPE / SEALANT

PROFILED INSIDE CORNER


TRIM W/ POP RIVETS @ 8"
3
4" PHIL. PAN HEAD O.C.

1
4" - 14 THROUGH FASTENERS
HORIZONTAL SUPPORT W/ 118" BONDED WASHER
(NOT BY KINGSPAN) (AS REQUIRED FOR WIND LOAD)

CONTINUOUS BUTYL
TAPE / SEALANT

REVISION
REVISION # DATE
1 1/27/21

DETAIL #: CI-IC-01-KSV
INSIDE CORNER
WITH PROFILED TRIM RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

WILL VARY WITH


FIELD CONDITION

FIELD CONDITION
WILL VARY WITH

FIELD CUT

1
4" - 14 "LOW PROFILE"
THROUGH FASTENER WITH
118" BONDED WASHER (AS
REQUIRED FOR WIND LOAD)

CONTINUOUS
BUTYL SEALANT
3
4" PHIL. PAN HEAD @ 8" O.C.

OUTSIDE CORNER TRIM

FILL ALL VOIDS WITH


COMPRESSED MINERAL
FIBER AS REQUIRED
(NOT BY KINGSPAN)

CONTINUOUS BUTYL
TAPE / SEALANT

CONTINUOUS INSIDE CORNER TRIM W/


BUTYL SEALANT POP RIVETS @ 8" O.C.
1
4" - 14 "LOW PROFILE"
THROUGH FASTENER WITH
HORIZONTAL SUPPORT
118" BONDED WASHER (AS
(NOT BY KINGSPAN) REQUIRED FOR WIND LOAD)

REVISION
REVISION # DATE
1 1/27/21

DETAIL #: CI-IC-02-KSV
INSIDE CORNER
WITH FLAT TRIM RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

VERTICAL SUPPORT
(NOT BY KINGSPAN)
1
4" - 14 "LOW PROFILE"
FASTENER CONTINUOUS
BUTYL SEALANT

CORNER EXTRUSION CAP

1
4" - 14 "LOW PROFILE"
COMPRESSED THROUGH FASTENER WITH
MINERAL FIBER AS 118" BONDED WASHER (AS
REQUIRED REQUIRED FOR WIND LOAD)
(NOT BY KINGSPAN)
CORNER EXTRUSION BASE

CONTINUOUS
BUTYL SEALANT

OPTIONAL WIPER
GASKET
(FIELD INSTALLED)

REVISION
REVISION # DATE
1 1/27/21

DETAIL #: CI-IC-03-KSV
INSIDE CORNER
WITH EXTRUSION RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FRAMING NOT SHOWN FOR


CLARITY OF DETAIL

CORNER TRIM

PLACE CORNER TRIM OVER


BASE TRIM FOR PROPER
DRAINAGE

CONTINUOUS
BUTYL SEALANT

BASE TRIM
CONTINUOUS BUTYL
SEALANT AT LAP
BETWEEN UPPER
AND LOWER TRIM
PIECE

SLAB SLAB REVISION


REVISION # DATE
0 01/01/21

DETAIL #: CI-IC-04-KSV
INSIDE CORNER LAP AT
BASE TRIM EXPANDED RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FRAMING NOT SHOWN FOR


CLARITY OF DETAIL
CONTINUOUS BUTYL
SEALANT FROM BOTTOM TO
TOP OF CORNER TRIM WITH
MARRIAGE BEADS AT ALL
PANEL JOINTS AND ALL
HORIZONTAL BEADS OF
BUTYL

CORNER TRIM

MARRIAGE BEAD TO
HORIZONTAL BEAD OF
SEALANT

CONTINUOUS
BUTYL SEALANT
OVER CORNER
TRIM

CONTINUOUS
BUTYL SEALANT

BASE TRIM
CONTINUOUS BUTYL
SEALANT AT LAP
BETWEEN UPPER
AND LOWER TRIM
PIECE

SLAB SLAB REVISION


REVISION # DATE
0 01/01/21

DETAIL #: CI-IC-05-KSV
INSIDE CORNER LAP AT
BASE TRIM ENGAGED RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
FRAMING NOT SHOWN FOR
CLARITY OF DETAIL

LAP UPPER CORNER


UPPER CORNER TRIM 3" TRIM MIN. 3" OVER
LOWER CORNER
TRIM

TRIM LAP

LOWER CORNER TRIM

CONTINUOUS BUTYL
SEALANT FROM BOTTOM TO
TOP OF CORNER TRIM WITH
MARRIAGE BEADS AT ALL
PANEL JOINTS AND ALL
HORIZONTAL BEADS OF
BUTYL

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-IC-06-KSV
INSIDE CORNER TRIM LAP
EXPANDED RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FRAMING NOT SHOWN FOR


CLARITY OF DETAIL

CONTINUOUS BUTYL
SEALANT FROM BOTTOM TO
TOP OF CORNER TRIM WITH
MARRIAGE BEADS AT ALL
PANEL JOINTS AND ALL
UPPER CORNER TRIM HORIZONTAL BEADS OF
BUTYL

TRIM LAP LAP UPPER CORNER


3" TRIM MIN. 3" OVER
LOWER CORNER
TRIM

LOWER CORNER TRIM

CONTINUOUS BUTYL
SEALANT FROM BOTTOM TO
TOP OF CORNER TRIM WITH
MARRIAGE BEADS AT ALL
PANEL JOINTS AND ALL
HORIZONTAL BEADS OF
BUTYL

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-IC-07-KSV
INSIDE CORNER TRIM LAP
ENGAGED RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

CONTINUOUS BUTYL SEALANT


BOTH SIDES OF TRIM W/
MARRIAGE BEAD TO
VERTICAL PANEL JOINT
1
4" - 14 "LOW PROFILE" CAP TRIM
THROUGH FASTENER @ 12" O.C.

CAP TRIM W/ POP


RIVETS @ 8" O.C. FRAMED OPENING
(NOT BY KINGSPAN)

FIELD DRILL 3 8" WEEP HOLES


TO ALIGN WITH PANEL JOINTS

EXPOSED SEALANT DOOR/WINDOW FRAME


(NOT BY KINGSPAN) AND COMPONENTS
(NOT BY KINGSPAN)

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV


FOR TYPICAL TRIM LAP INSTRUCTIONS
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-01-KSV
FRAMED OPENING
TWO-PIECE HEAD RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

1
CONTINUOUS BUTYL
4"
- 14 "LOW PROFILE" SEALANT BOTH SIDES OF
THROUGH FASTENER @ 12" O.C. TRIM W/ MARRIAGE BEAD TO
BASE TRIM W/ POP RIVETS VERTICAL PANEL JOINT
@ 8" O.C.

FRAMED OPENING
(NOT BY KINGSPAN)

DOOR/WINDOW FRAME
DRIP FLASHING
AND COMPONENTS
(NOT BY KINGSPAN)
EXPOSED SEALANT
(NOT BY KINGSPAN)

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV


FOR TYPICAL TRIM LAP INSTRUCTIONS
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-02-KSV
FRAMED OPENING
HEAD W/ "DRIP EDGE" RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FRAMED OPENING
(NOT BY KINGSPAN)

DOOR/WINDOW FRAME
AND COMPONENTS
(NOT BY KINGSPAN)
1
4" - 14 "LOW PROFILE"
THROUGH FASTENER @ 12" O.C.

CONTINUOUS BUTYL SEALANT


BOTH SIDES OF TRIM

CAP TRIM

EXPOSED SEALANT
(NOT BY KINGSPAN)

POP RIVETS @ 8" O.C.

BUTYL SEALANT
BETWEEN TRIMS CONTINUOUS BUTYL TAPE /
SEALANT

EXTERIOR CAP TRIM W/


POP RIVETS @ 8" O.C.

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV


FOR TYPICAL TRIM LAP INSTRUCTIONS
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-03-KSV
FRAMED OPENING
TWO PIECE JAMB RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FRAMED OPENING FIELD BEND


(NOT BY KINGSPAN) (AS REQUIRED)

1
4" - 14 "LOW PROFILE"
DOOR/WINDOW FRAME FASTENER (AS REQUIRED)
AND COMPONENTS
(NOT BY KINGSPAN)
CONTINUOUS BUTYL SEALANT

1
4" - 14 "LOW PROFILE"
THROUGH FASTENER

CONTINUOUS BUTYL SEALANT

EXPOSED SEALANT
(NOT BY KINGSPAN)

CONTINUOUS BUTYL TAPE /


SEALANT

JAMB TRIM W/ POP


RIVETS @ 8" O.C.

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV


FOR TYPICAL TRIM LAP INSTRUCTIONS
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-04-KSV
FRAMED OPENING
ONE PIECE JAMB RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

DOOR/WINDOW FRAME
EXPOSED SEALANT AND COMPONENTS
(NOT BY KINGSPAN) (NOT BY KINGSPAN)

FIELD BEND
(AS REQUIRED)

SILL TRIM W/ POP SLOPE


RIVETS @ 8" O.C.

FRAMED OPENING
(NOT BY KINGSPAN)

1
1
4"
- 14 "LOW PROFILE" 4" - 14 "LOW PROFILE"
THROUGH FASTENER FASTENER (AS REQUIRED)
CONTINUOUS BUTYL
SEALANT
CONTINUOUS BUTYL
SEALANT W/ MARRIAGE BEAD
TO PANEL FACE AT JOINTS

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV


FOR TYPICAL TRIM LAP INSTRUCTIONS
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-05-KSV
FRAMED OPENING
ONE PIECE SILL RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
CAP TRIM

PHIL. PAN HEAD FASTENERS

CONTINUOUS BUTYL SEALANT


CAP TRIM

PHIL. PAN HEAD FASTENERS

CONTRACTOR MAY REMOVE A PORTION


OF THE FOAM CORE AND INSERT TREATED
LUMBER (NOT BY KINGSPAN) TO REINFORCE
LARGE OPENINGS

CONTINUOUS BUTYL SEALANT


CAP TRIM

CONTINUOUS
BUTYL SEALANT

THROUGH BOLT AS
REQUIRED FOR ATTACHMENT
OF DOOR CASING
(NOT BY KINGSPAN)
CONTRACTOR MAY REMOVE A
PORTION OF THE FOAM CORE
AND INSERT TREATED LUMBER
(NOT BY KINGSPAN) TO
REINFORCE LARGE OPENINGS

DOOR CASING
(NOT BY KINGSPAN)
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-06-KSV
FRAMED OPENING
PARTITION RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

2
CAP TRIM
1
4"
- 14 "LOW PROFILE"
THROUGH FASTENER CONTINUOUS BUTYL SEALANT
BOTH SIDES OF TRIM W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
3
CAP TRIM W/ POP FRAMED OPENING
RIVETS @ 8" O.C. (NOT BY KINGSPAN)

FASTENER
FIELD DRILL 3 8" WEEP HOLES
(NOT BY KINGSPAN)
TO ALIGN WITH PANEL JOINTS
1
HEADER TRIM
(OPTIONAL)
EXPOSED SEALANT
(NOT BY KINGSPAN)

TRIM INSTALLATION SEQUENCE:


1 INSTALL HEADER TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS
2 INSTALL INTERIOR CAP TRIM & ALL APPLICABLE SEALANTS PRIOR TO
INSTALLING THE PANEL AND THROUGH FASTENERS
3 INSTALL EXTERIOR CAP TRIM

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV


FOR TYPICAL TRIM LAP INSTRUCTIONS
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-07-KSV
OVERHEAD DOOR
TWO PIECE HEADER RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
1
4" - 14 "LOW PROFILE"
CONTINUOUS BUTYL SEALANT
THROUGH FASTENER BOTH SIDES OF TRIM W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT

3
BASE TRIM W/ POP
FRAMED OPENING
RIVETS @ 8" O.C.
(NOT BY KINGSPAN)

2 FASTENER
DRIP FLASHING
(NOT BY KINGSPAN)
1
HEADER TRIM
EXPOSED SEALANT (OPTIONAL)
(NOT BY KINGSPAN)

TRIM INSTALLATION SEQUENCE:


1 INSTALL HEADER TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS
2 INSTALL DRIP FLASHING & ALL APPLICABLE SEALANTS PRIOR TO
INSTALLING THE PANEL AND THROUGH FASTENERS
3 INSTALL EXTERIOR CAP TRIM

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV


FOR TYPICAL TRIM LAP INSTRUCTIONS
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-08-KSV
OVERHEAD DOOR
HEAD W/ DRIP EDGE RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FASTENER
(NOT BY KINGSPAN)

FRAMED OPENING
(NOT BY KINGSPAN)

1
4" - 14 "LOW PROFILE"
THROUGH FASTENER
1
JAMB TRIM CONTINUOUS BUTYL SEALANT
(OPTIONAL) BOTH SIDES OF TRIM
2
CAP TRIM

EXPOSED SEALANT
(NOT BY KINGSPAN)

POP RIVETS @ 8" O.C.

3
CAP TRIM W/ POP RIVETS @ 8" O.C.

TRIM INSTALLATION SEQUENCE:


1 INSTALL JAMB TRIM (OPTIONAL) & ALL APPLICABLE SEALANTS
2 INSTALL INTERIOR CAP TRIM & ALL APPLICABLE SEALANTS PRIOR TO
INSTALLING THE PANEL AND THROUGH FASTENERS
3 INSTALL EXTERIOR CAP TRIM

NOTE: SEE DETAIL CI-TL-01-KSV, CI-TL-02-KSV, AND CI-TL-04-KSV


FOR TYPICAL TRIM LAP INSTRUCTIONS
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-09-KSV
OVERHEAD DOOR
TWO-PIECE JAMB RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

CONTINUOUS BUTYL SEALANT


BOTH SIDES OF TRIM W/
MARRIAGE BEAD TO VERTICAL
PANEL JOINT
1 1
4"
- 14 "LOW PROFILE" 4" - 14 "LOW PROFILE"
THROUGH FASTENER FASTENER

TWO PIECE HEAD


EXTRUSION CAP
FRAMED OPENING
(NOT BY KINGSPAN)

FIELD DRILL 3 8" Ø WEEP


HOLES @ 24" O.C. AND AT ALL
VERTICAL JOINTS WHERE
POSSIBLE
(NOT BY KINGSPAN) DOOR/WINDOW FRAME
AND COMPONENTS
(NOT BY KINGSPAN)
TWO PIECE HEAD
EXTRUSION BASE
W/ FOAM CLOSURE
EXPOSED SEALANT
(NOT BY KINGSPAN)

OPTIONAL WIPER
GASKET
(FIELD INSTALLED) REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-10-KSV
HEADER W/
EXTRUSION RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FRAMED OPENING
(NOT BY KINGSPAN)

DOOR/WINDOW FRAME
AND COMPONENTS
(NOT BY KINGSPAN)

1
4" - 14 "LOW PROFILE"
THROUGH FASTENER

CONTINUOUS BUTYL SEALANT


BOTH SIDES OF EXTRUSION

EXPOSED SEALANT
(NOT BY KINGSPAN)

TWO PIECE JAMB


EXTRUSION BASE W/
FOAM CLOSURE

FIELD CUT PANELS WHERE


REQUIRED

TWO PIECE JAMB


EXTRUSION CAP

OPTIONAL WIPER
GASKET REVISION
(FIELD INSTALLED) REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-11-KSV
JAMB W/ EXTRUSION
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

EXPOSED SEALANT
(NOT BY KINGSPAN) DOOR/WINDOW FRAME
AND COMPONENTS
SILL EXTRUSION
(NOT BY KINGSPAN)
FIELD CUT PANEL
WHERE REQUIRED

OPTIONAL WIPER
GASKET
(FIELD INSTALLED) 1
4" - 14 "LOW PROFILE"
FASTENER

FRAMED OPENING
(NOT BY KINGSPAN)
1
4" - 14 "LOW PROFILE"
THROUGH FASTENER CONTINUOUS BUTYL SEALANT
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO PANEL FACE
AT JOINTS

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-12-KSV
SILL W/ EXTRUSION
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

CONTINUOUS BUTYL SEALANT


BOTH SIDES OF EXTRUSION W/
MARRIAGE BEAD TO VERTICAL
1
4" - 14 "LOW PROFILE" PANEL JOINT
THROUGH FASTENER

1
4" - 14 "LOW PROFILE"
TWO PIECE HEAD THROUGH FASTENER
EXTRUSION CAP

FRAMED OPENING
(NOT BY KINGSPAN)

FASTENER
FIELD DRILL 3 8" Ø WEEP (NOT BY KINGSPAN)
HOLES @ 24" O.C. AND AT ALL HEADER TRIM
VERTICAL JOINTS WHERE (OPTIONAL)
POSSIBLE
(NOT BY KINGSPAN)

TWO PIECE HEAD


EXTRUSION BASE
W/ FOAM CLOSURE

EXPOSED SEALANT
(NOT BY KINGSPAN)
OPTIONAL WIPER
GASKET
(FIELD INSTALLED)

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-13-KSV
O.H. DOOR HEAD W/
EXTRUSION RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FASTENER
(NOT BY KINGSPAN)

FRAMED OPENING
(NOT BY KINGSPAN)

JAMB TRIM 1
4" - 14 "LOW PROFILE"
(OPTIONAL) THROUGH FASTENER
1
4" - 14 "LOW PROFILE"
FASTENERS WITH WASHER
CONTINUOUS BUTYL
SEALANT BOTH SIDES OF
EXTRUSION

EXPOSED SEALANT
(NOT BY KINGSPAN)

TWO PIECE JAMB


EXTRUSION BASE

FIELD CUT PANELS WHERE


REQUIRED
TWO PIECE JAMB
EXTRUSION CAP

OPTIONAL WIPER
GASKET
(FIELD INSTALLED) REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-FO-14-KSV
O.H. DOOR JAMB W/
EXTRUSION RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
12 GA. STAINLESS STEEL
ARE NO GAPS IN SEALANT
HIDDEN FASTENER CLIP
(1 PER PANEL, PER SUPPORT) 1
SET CLIP IN BUTYL SEALANT 4" - 14 HEX HEAD
FASTENERS WITHOUT WASHER

STACK TRIM W/ CONTINUOUS BUTYL SEALANT BOTH


POP RIVETS @ SIDES OF TRIM W/ MARRIAGE BEAD
8" O.C. TO VERTICAL PANEL JOINT

HORIZONTAL SUPPORT
(NOT BY KINGSPAN)
STACK FLASHING

FASTEN AS REQUIRED
CONTINUOUS BUTYL (NOT BY KINGSPAN)
SEALANT BELOW BASE
FLASHING
CONTINUOUS BUTYL SEALANT W/
MARRIAGE BEAD TO FACE OF PANEL
AT JOINTS

CONTINUOUS 3" X 3"


(GAUGE TO MATCH GIRT)
(NOT BY KINGSPAN)

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-SJ-01-KSV
STACK JOINT
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

1
4" - 14 HEX HEAD
FASTENERS WITHOUT WASHER
1
4" - 14 "LOW PROFILE"
THROUGH FASTENER
12 GA. STAINLESS STEEL
HIDDEN FASTENER CLIP CONTINUOUS BUTYL SEALANT BOTH
(1 PER PANEL, PER SUPPORT) SIDES OF EXTRUSION W/ MARRIAGE
SET CLIP IN BUTYL SEALANT BEAD TO VERTICAL PANEL JOINT
HORIZONTAL SUPPORT
TWO PIECE STACK (NOT BY KINGSPAN)
EXTRUSION CAP

FIELD DRILL 3 8"Ø FASTEN AS REQUIRED


WEEP HOLES @ 24" (NOT BY KINGSPAN)
O.C. AND AT ALL
VERTICAL JOINTS COMPRESSIBLE
WHERE POSSIBLE FOAM CLOSURE
(NOT BY KINGSPAN)

CONTINUOUS BUTYL SEALANT W/


MARRIAGE BEAD TO PANEL FACE AT
JOINTS

CONTINUOUS 3" X 3"


(GAUGE TO MATCH GIRT)
(NOT BY KINGSPAN)

TWO PIECE STACK


EXTRUSION BASE
OPTIONAL WIPER
GASKET
(FIELD INSTALLED) FIELD OR FACTORY INSTALLED
CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-SJ-02-KSV
STACK JOINT WITH
EXTRUSION RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

PARAPET BLOCKING
AND COMPONENTS
(NOT BY KINGSPAN)
12 GA. STAINLESS STEEL
HIDDEN FASTENER CLIP
(1 PER PANEL, PER SUPPORT) CONTINUOUS BUTYL
SET CLIP IN BUTYL SEALANT SEALANT W/ MARRIAGE
BEAD TO MEMBRANE AT
PARAPET CAP PANEL FACE

WRAP MEMBRANE
ADHERE TO EXTERIOR
PANEL FACE FASTENER TO PARAPET
(NOT BY KINGSPAN) BACKER (NOT BY KINGSPAN)
1
4" - 14 "LOW PROFILE"
FASTENER @ 8" O.C.

CONTINUOUS CLEAT

1
4" - 14 HEX HEAD MEMBRANE ROOF &
FASTENERS WITHOUT WASHER
PARAPET BACKER
(NOT BY KINGSPAN)

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-PR-01-KSV
PARAPET
WITH FLUSH TRIM RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

PARAPET BLOCKING
AND COMPONENTS
(NOT BY KINGSPAN)
WRAP MEMBRANE
(NOT BY KINGSPAN)

CONTINUOUS BUTYL
12 GA. STAINLESS STEEL SEALANT W/ MARRIAGE
HIDDEN FASTENER CLIP BEAD TO MEMBRANE AT
(1 PER PANEL, PER SUPPORT) PANEL FACE
SET CLIP IN BUTYL SEALANT

WRAP MEMBRANE
FASTENER TO PARAPET
ADHERE TO EXTERIOR
BACKER (NOT BY KINGSPAN)
PANEL FACE
(NOT BY KINGSPAN)

POP RIVET @ 8" O.C.

1
4" - 14 HEX HEAD PARAPET BACKER
FASTENERS WITHOUT WASHER
(NOT BY KINGSPAN)

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-PR-02-KSV
PARAPET
WITH PROFILED TRIM RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

CONTINUOUS 1
4" - 14 "LOW PROFILE"
BUTYL SEALANT THROUGH FASTENER

PARAPET EXTRUSION CONTINUOUS BUTYL


SEALANT W/ MARRIAGE
BEAD TO FACE OF PANEL
FIELD CUT MALE JOINTS
WHERE REQUIRED 1
4" - 14 HEX HEAD
FASTENERS WITH WASHER
WRAP MEMBRANE
(NOT BY KINGSPAN)
ADHERE TO EXTERIOR
PANEL FACE
FASTENER TO PARAPET
BACKER (NOT BY KINGSPAN)

1
4" - 14 HEX HEAD FASTENERS
WITHOUT WASHER

12 GA. STAINLESS STEEL PARAPET CAP TRIM


HIDDEN FASTENER CLIP
(1 PER PANEL, PER SUPPORT)
SET CLIP IN BUTYL SEALANT
MEMBRANE ROOF &
PARAPET BACKER
(NOT BY KINGSPAN)

FIELD OR FACTORY INSTALLED


CONTINUOUS BUTYL SEALANT
IN VERTICAL PANEL JOINT
INSTALLER TO ENSURE THERE
ARE NO GAPS IN SEALANT

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-PR-03-KSV
PARAPET
WITH EXTRUSION RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
FIELD OR FACTORY
INSTALLED CONTINUOUS
BUTYL SEALANT IN
VERTICAL PANEL JOINT
INSTALLER TO ENSURE
THERE ARE NO GAPS IN 12 GA. HIDDEN FASTENER
SEALANT CLIP
(1 PER PANEL, PER GIRT)

BASE TRIM W/ POP RIVETS


BASE FLASHING
@ 8" O.C.

MEMBRANE ROOF AND


ACCESSORIES
(2) 1 4" - 14 HEX (NOT BY KINGSPAN
HEAD FASTENERS
PER CLIP BASE FLASHING

CONTINUOUS BUTYL
SEALANT W/ MARRIAGE
BEAD TO VERTICAL JOINT

FLAT STOCK MATERIAL


(FIELD BREAK BY OTHERS)

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-WR-01-KSV
WALL TO ROOF
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
CONTINUOUS BUTYL
SEALANT IN INTERIOR 12 GA. HIDDEN FASTENER
JOINT CLIP
(1 PER PANEL, PER GIRT)
MEMBRANE
(NOT BY KINGSPAN) BASE TRIM W/ POP RIVETS

BASE FLASHING
CONTINUOUS BUTYL
(2) 1 4" - 14 HEX HEAD SEALANT W/ MARRIAGE
FASTENERS PER BEAD TO EXTERIOR
CLIP VERTICAL JOINT

SUPPORT
(NOT BY KINGSPAN)

CONTINUOUS BUTYL
SEALANT W/ 12 GA. HIDDEN FASTENER
MARRIAGE BEAD TO CLIP
VERTICAL JOINT (1 PER PANEL, PER GIRT)

MIN 6"
(2) 1 4" - 14 HEX HEAD MEMBRANE ROOF,
FASTENERS PER FRAMING AND
CLIP ACCESSORIES
(NOT BY KINGSPAN)
SUPPORT
(NOT BY KINGSPAN)

CONTINUOUS BUTYL
SEALANT IN INTERIOR
JOINT

FIELD OR FACTORY
INSTALLED CONTINUOUS
BUTYL SEALANT IN
VERTICAL PANEL JOINT
INSTALLER TO ENSURE
THERE ARE NO GAPS IN
SEALANT

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-WR-02-KSV
CONTINUOUS WALL AT
ROOF / CANOPY RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

CONTINUOUS BUTYL
(2) 1 4" - 14 HEX HEAD
SEALANT AT PANEL
FASTENERS WITHOUT
JOINT
WASHER PER CLIP

CONTINUOUS BUTYL
12 GA. STAINLESS STEEL SEALANT BOTH SIDES
HIDDEN FASTENER CLIP OF TRIM W/ MARRIAGE
(1 PER PANEL, PER BEAD TO INTERIOR
SUPPORT) JOINT
SET CLIP IN BUTYL
SEALANT CONTINUOUS BUTYL
SEALANT BOTH SIDES
OF TRIM
BASE TRIM W/ POP
RIVETS @ 8" O.C.

POP RIVETS @ 8" O.C.

SOFFIT FLASHING 1
4" - 14 "LOW PROFILE"
THROUGH FASTENER

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-SO-01-KSV
WALL ABOVE TO
HORIZONTAL SOFFIT RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

1
4" - 14 "LOW PROFILE"
THROUGH FASTENER

CONTINUOUS BUTYL
SEALANT

OUTSIDE CORNER
TRIM

CONTINUOUS BUTYL
SEALANT W/
MARRIAGE BEAD TO
PANEL FACE AT
JOINTS
INSIDE CORNER TRIM
W/ POP RIVETS @ 8"
O.C.

BUTYL SEALANT OR
TAPE
(2) 1 4" - 14 HEX HEAD
FASTENERS WITHOUT
BACKER ROD AND
WASHER PER CLIP
SEALANT
(NOT BY KINGSPAN)
CONTINUOUS BUTYL
12 GA. STAINLESS STEEL SEALANT AT PANEL
HIDDEN FASTENER CLIP JOINT
(1 PER PANEL, PER SUPPORT)
SET CLIP IN BUTYL SEALANT

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-SO-02-KSV
WALL BELOW TO
HORIZONTAL SOFFIT RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

1 CONTINUOUS BUTYL
4"
- 14 HEX HEAD
SEALANT AT PANEL
FASTENERS WITHOUT
JOINT
WASHER

12 GA. STAINLESS STEEL


HIDDEN FASTENER CLIP
(1 PER PANEL, PER
SUPPORT) CONTINUOUS BUTYL
SET CLIP IN BUTYL SEALANT BOTH SIDES
SEALANT OF TRIM W/ MARRIAGE
BEAD TO INTERIOR
JOINT
BASE TRIM W/ POP
RIVETS @ 8" O.C.

POP RIVETS @ 8" O.C.

SOFFIT FLASHING 1
4" - 14 "LOW PROFILE"
THROUGH FASTENER

CONTINUOUS BUTYL
SEALANT MARRIAGE
BEAD TO PANEL FACE
AT JOINTS

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-SO-03-KSV
WALL ABOVE TO
VERTICAL SOFFIT RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

1
4" - 14 "LOW PROFILE"
THROUGH FASTENER

CONTINUOUS BUTYL
SEALANT

CONTINUOUS BUTYL
SEALANT MARRIAGE
BEAD TO PANEL FACE
AT JOINTS
OUTSIDE CORNER
TRIM

CONTINUOUS BUTYL
SEALANT W/
MARRIAGE BEAD TO
PANEL FACE AT
JOINTS

INSIDE CORNER TRIM


W/ POP RIVETS @ 8"
O.C.

BACKER ROD AND (2) 1 4" - 14 HEX HEAD


SEALANT FASTENERS WITHOUT
(NOT BY KINGSPAN) WASHER PER CLIP

12 GA. STAINLESS STEEL CONTINUOUS BUTYL


HIDDEN FASTENER CLIP SEALANT AT PANEL
(1 PER PANEL, PER SUPPORT) JOINT
SET CLIP IN BUTYL SEALANT

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-SO-04-KSV
WALL BELOW TO
VERTICAL SOFFIT RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FASTENER AS REQUIRED FASTENER AS REQUIRED

SEALANT SEALANT (NOT BY KINGSPAN)


(NOT BY KINGSPAN)
2PC. FLASHING AS REQUIRED
(FIELD FABRICATED FROM
FLATSTOCK)

EXPANDABLE INSULATION
(NOT BY KINGSPAN)

EXPANDABLE INSULATION
(NOT BY KINGSPAN)
2 PC. FLASHING AS REQUIRED

SEALANT (NOT BY KINGSPAN) SEALANT (NOT BY KINGSPAN)

FASTENER AS REQUIRED FASTENER AS REQUIRED

NOTE: FLASHING AT PIPE PENETRATIONS


TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
FLATSTOCK REQUIRED SHALL BE PROVIDED
(NOT BY KINGSPAN)

NOTE:
DO NOT ALIGN PENETRATIONS
AT PANEL JOINT LOCATIONS. REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-PE-01-KSV
PIPE PENETRATION
SECTION RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
INSULATED PANEL

SILICONE SEALANT
AT TOP OF FLASHING
(NOT BY KINGSPAN)

SILICONE SEALANT AT
PERIMETER OF PIPE
(NOT BY KINGSPAN)

SILICONE SEALANT
BETWEEN FLASHINGS
(NOT BY KINGSPAN)

PIPE PENETRATION
(NOT BY KINGSPAN)

TWO PIECE FLASHING


WITH 12" HEM. BED
SEAL TO PANEL WITH
BUTYL SEALANT (BLIND)
COPE FLASHING (FIELD
FABRICATED FROM
FLATSTOCK)
POP RIVETS
(QUANTITY REQUIRED SHALL
NOTE: BE DETERMINED BY INSTALLER)
DO NOT ALIGN PENETRATIONS
AT PANEL JOINT LOCATIONS. NOTE: FLASHING AT PENETRATIONS
TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
NOTE: FLATSTOCK REQUIRED SHALL BE DETERMINED BY INSTALLER
THIS DETAIL ASSUMES (NOT BY KINGSPAN)
PENETRATION OCCURS REVISION
AFTER PANEL IS INSTALLED REVISION # DATE
0 01/01/21

DETAIL #: CI-PE-02-KSV
PIPE PENETRATION
ISOMETRIC RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
INSULATED PANEL NOTE: FLASHING AT PENETRATIONS
TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
FLATSTOCK REQUIRED SHALL BE DETERMINED
BY INSTALLER
(NOT BY KINGSPAN)
SILICONE SEALANT
AT TOP OF FLASHING
(NOT BY KINGSPAN)

POP RIVETS
TWO PIECE FLASHING (QUANTITY REQUIRED SHALL
BE DETERMINED BY INSTALLER)
WITH 12" HEM. BED
SEAL TO PANEL WITH
BUTYL SEALANT (BLIND)
COPE FLASHING
(NOT BY KINGSPAN)

SILICONE SEALANT
BETWEEN FLASHINGS
(NOT BY KINGSPAN)
KNIFE PENETRATION
(NOT BY KINGSPAN)
SILICONE SEALANT AT
PERIMETER OF KNIFE
(NOT BY KINGSPAN)

INSULATED PANEL

SILICONE SEALANT SILICONE SEALANT AT


AT TOP OF FLASHING NOTE:
PERIMETER OF KNIFE
(NOT BY KINGSPAN) DO NOT ALIGN
(NOT BY KINGSPAN)
PENETRATIONS
POP RIVETS FILL VOID WITH F.I.P AT PANEL JOINT
INSULATION LOCATIONS.
(NOT BY KINGSPAN)

KNIFE PENETRATION NOTE: THIS DETAIL ASSUMES


PENETRATION OCCURS
REVISION
AFTER PANEL IS INSTALLED REVISION # DATE
0 01/01/21

DETAIL #: CI-PE-03-KSV
KNIFE PLATE
PENETRATION RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
NOTE: FLASHING AT PENETRATIONS
TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
FLATSTOCK REQUIRED SHALL BE DETERMINED
BY INSTALLER
(NOT BY KINGSPAN)
INSULATED PANEL

SILICONE SEALANT
AT TOP OF FLASHING
(NOT BY KINGSPAN)
POP RIVETS
(QUANTITY REQUIRED
SHALL BE DETERMINED SILICONE SEALANT AT
BY INSTALLER) PERIMETER OF KNIFE
(NOT BY KINGSPAN)

SILICONE SEALANT
TWO PIECE FLASHING BETWEEN FLASHINGS
WITH 12" HEM. BED (NOT BY KINGSPAN)
SEAL TO PANEL WITH
BUTYL SEALANT (BLIND)
COPE FLASHING
(NOT BY KINGSPAN)
KNIFE PENETRATION
(NOT BY KINGSPAN)

NOTE: THIS DETAIL ASSUMES NOTE:


PENETRATION OCCURS DO NOT ALIGN PENETRATIONS
AFTER PANEL IS INSTALLED AT PANEL JOINT LOCATIONS.
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-PE-04-KSV
KNIFE PLATE
PENETRATION ISOMETRIC RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
INSULATED PANEL NOTE: FLASHING AT PENETRATIONS
TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
FLATSTOCK REQUIRED SHALL BE DETERMINED
BY INSTALLER
(NOT BY KINGSPAN)
SILICONE SEALANT
AT TOP OF FLASHING SILICONE SEALANT
(NOT BY KINGSPAN) BETWEEN FLASHINGS
(NOT BY KINGSPAN)

TWO PIECE FLASHING


WITH 12" HEM. BED POP RIVETS
SEAL TO PANEL WITH (QUANTITY REQUIRED
BUTYL SEALANT (BLIND) SHALL BE DETERMINED
COPE FLASHING BY INSTALLER)
(NOT BY KINGSPAN)

BEAM PENETRATION
(NOT BY KINGSPAN)
SILICONE SEALANT AT
PERIMETER OF BEAM
(NOT BY KINGSPAN)

INSULATED PANEL

SILICONE SEALANT SILICONE SEALANT AT


AT TOP OF FLASHING NOTE:
PERIMETER OF BEAM
(NOT BY KINGSPAN) DO NOT ALIGN
(NOT BY KINGSPAN)
PENETRATIONS
BEAM PENETRATION FILL VOID WITH F.I.P AT PANEL JOINT
INSULATION LOCATIONS.
(NOT BY KINGSPAN)
POP RIVETS
NOTE: THIS DETAIL ASSUMES
PENETRATION OCCURS REVISION
REVISION # DATE
AFTER PANEL IS INSTALLED 0 01/01/21

DETAIL #: CI-PE-05-KSV
BEAM PENETRATION
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

INSULATED PANEL

SILICONE SEALANT
AT TOP OF FLASHING
(NOT BY KINGSPAN)

SILICONE SEALANT
BETWEEN FLASHINGS
(NOT BY KINGSPAN)

SILICONE SEALANT AT
POP RIVETS PERIMETER OF BEAM
(QUANTITY REQUIRED (NOT BY KINGSPAN)
SHALL BE DETERMINED
BY INSTALLER)

TWO PIECE FLASHING


WITH 12" HEM. BED
SEAL TO PANEL WITH
BUTYL SEALANT (BLIND)
COPE FLASHING
(NOT BY KINGSPAN)
BEAM PENETRATION
(NOT BY KINGSPAN)

NOTE: FLASHING AT PENETRATIONS


TO BE FIELD FABRICATED FROM FLATSTOCK
SHEETS AS NECESSARY. QUANTITY OF
FLATSTOCK REQUIRED SHALL BE DETERMINED
BY INSTALLER
(NOT BY KINGSPAN)

NOTE: THIS DETAIL ASSUMES NOTE:


PENETRATION OCCURS DO NOT ALIGN PENETRATIONS
REVISION
AFTER PANEL IS INSTALLED AT PANEL JOINT LOCATIONS. REVISION # DATE
0 01/01/21

DETAIL #: CI-PE-06-KSV
BEAM PENETRATION
ISOMETRIC RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

3"
I N. AP
M L
IM
TR
(2) BEADS
BUTYL SEALANT

3"
N. P
MI LA
I M
TR

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-TL-01-KSV
TRIM END LAP
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

FIELD NOTCH HEM(S)


AS REQUIRED
(NOT BY KINGSPAN)

3"
N. P
MI LA
I M
TR
(2) BEADS
BUTYL SEALANT

3"
N. P
MI LA
I M
TR

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-TL-02-KSV
TRIM LAP WITH HEM
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

(2) BEADS
BUTYL SEALANT

8" LONG LAP STRIP

1 4"
OM.
N P
GA

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-TL-03-KSV
TRIM END LAP WITH
LAP STRIP RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
FIELD NOTCH AND OVERLAP
TRIMS, POP RIVET AND SEAL AS
NECESSARY (NOT BY KINGSPAN)

SEALANT END DAM FIELD MITER AND OVERLAP


TRIMS, POP RIVET AS
NECESSARY (NOT BY KINGSPAN)
2
INTERIOR HEAD TRIM
WITH TABS BENT DOWN

D
H EA
AT
M
TRI
C AP
IOR EA
D
ER H
IN
T AT
IM
P TR
R CA FIELD CUT/NOTCH CAP

EXTERIOR CAP TRIM AT JAMB


IO TRIM AT CORNERS TO
T ER
EX ALLOW FOR LAP
(NOT BY KINGSPAN)

5
EXTERIOR HEAD TRIM W/
FIELD DRILL 3 8" Ø WEEP HOLES 4
EXTERIOR JAMB TRIM
(NOT BY KINGSPAN)
1
INTERIOR JAMB TRIM
6
EXPOSED SEALANT
(NOT BY KINGSPAN) FIELD CUT/NOTCH CAP
3 TRIM AT CORNERS TO
SILL TRIM WITH TABS ALLOW FOR LAP
BENT UP (NOT BY KINGSPAN)

FIELD MITER AND OVERLAP


TRIMS, POP RIVET AND SEAL AS
L
T SIL NECESSARY (NOT BY KINGSPAN)
A
IM
P TR
A
RC TRIM INSTALLATION SEQUENCE:
RIO 1 INTERIOR JAMB TRIM
XTE
E 2 INTERIOR HEAD TRIM WITH TABS DOWN
3 SILL TRIM WITH TABS UP
4 EXTERIOR JAMB TRIM
5 EXTERIOR HEAD TRIM
6 EXTERIOR SEALANTS AS REQUIRED
REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-TL-04-KSV
TRIM LAP AT
FRAMED OPENING RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
TRIM INSTALLATION SEQUENCE:
1 INTERIOR JAMB TRIM (NOTCH) 5
2 DRIP FLASHING HEAD TRIM WITH TABS BENT DOWNS
3 SILL TRIMS WITH TABS BENT UP D
4 EXTERIOR JAMB TRIM H EA
AT
5 EXTERIOR CAP TRIM AT HEAD
RIM
PT
CA

2
D
H EA
AT
G
HIN
AS
FL
RIP

EXTERIOR CAP
TRIM AT JAMB
D
MIN. 3" TAB FOLD OVER
INTERIOR JAMB TRIM,

INTERIOR CAP
TRIM AT JAMB
APPLY SEALANT IN
BETWEEN (TYPICAL
BOTH ENDS)
INTERIOR CAP
TRIM AT JAMB

4
1
EXTERIOR CAP
TRIM AT JAMB

IM
MIN. 3" TAB FOLD OVER L TR
INTERIOR JAMB TRIM, APPLY SIL EXPLODED VIEW
3
SEALANT IN BETWEEN
(TYPICAL BOTH ENDS) REVISION
REVISION # DATE
0 01/01/21

TRIM LAP AT DETAIL #: CI-TL-05-KSV


FRAMED OPENING
RELEASE: 2021 www.kingspanpanels.us
INSTALLATION www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
DRIP FLASHING AT HEAD
CARRY FIELD APPLIED REAR
SEAL NON-SKINNING BUTYL
SEALANT BEAD OVER TOP
OF THE FLEXWRAP TAPE

4" LAP BED SEALED IN


BUTYL CAULK

PERFORM THIS WORK


PRIOR TO PANEL
INSTALLATION

USE DUPONT
1" TAB DOWN BED SEALED IN FLEXWRAP NF
BUTYL CAULK TAPE 6" x 6"
PATCH
CARRY FIELD APPLIED REAR
SEAL NON-SKINNING BUTYL
SEALANT BEAD OVER TOP
OF THE FLEXWRAP TAPE
JAMB TRIM,
SHINGLE LAPPED

USE DUPONT
FLEXWRAP NF

SILL TRIM

4" LAP BED


SEALED IN
BUTYL CAULK
1" TAB UP BED SEALED IN
BUTYL CAULK

REVISION
REVISION # DATE
3 3/03/21

OPTIONAL FLEX WRAP DETAIL #: CI-TL-06-KSV


AT
RELEASE: 2021 www.kingspanpanels.us
FRAMED OPENING www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

TWO PIECE OPENING 2" TWO PIECE OPENING


EXTRUSION CAP EXTRUSION BASE
PART # 2-0215 PART # 2-0214

PARAPET EXTRUSION
PART # 2-1598

OPTIONAL WIPER
GASKET
(FIELD INSTALLED)

2" CORNER
FEMALE EXTRUSION 2" PANEL BASE "B"
PART # 2-4042 EXTRUSION
2" CORNER
MALE EXTRUSION PART # 2-4049
PART # 2-3998

SILL EXTRUSION
PART # 2-4064

TWO PIECE STACK JOINT 2" STACK JOINT


EXTRUSION CAP EXTRUSION BASE
DIE #13948 DIE #14009

REVISION
REVISION # DATE
2 2/03/21

DETAIL #: CI-TL-07-KSV
2" EXTRUSIONS
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

TWO PIECE OPENING 212" TWO PIECE OPENING


EXTRUSION CAP EXTRUSION BASE
PART # 2-0215 PART # 2-1063

PARAPET EXTRUSION
PART # 2-1598

OPTIONAL WIPER
GASKET
(FIELD INSTALLED)

212" CORNER
FEMALE EXTRUSION
212" PANEL BASE "B"
PART # 2-4072 1 EXTRUSION
2 2" CORNER
MALE EXTRUSION PART # 2-4050
PART # 2-3999

SILL EXTRUSION
PART # 2-4064

TWO PIECE STACK JOINT 212" STACK JOINT


MALE EXTRUSION FEMALE EXTRUSION
DIE #2-4070 PART # 2-4065

REVISION
REVISION # DATE
2 2/03/21

DETAIL #: CI-TL-08-KSV
1
2 2" EXTRUSIONS
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

TWO PIECE OPENING 3" TWO PIECE OPENING


EXTRUSION CAP EXTRUSION BASE
PART # 2-0215 PART # 2-0269

PARAPET EXTRUSION
PART # 2-1598

OPTIONAL WIPER
GASKET
(FIELD INSTALLED)

3" CORNER
FEMALE EXTRUSION 3" PANEL BASE "B"
PART # 2-4043 EXTRUSION
3" CORNER
MALE EXTRUSION PART # 2-4051
PART # 2-4000

SILL EXTRUSION
PART # 2-4064

TWO PIECE STACK JOINT 3" STACK JOINT


MALE EXTRUSION FEMALE EXTRUSION
DIE #2-4070 PART # 2-4066

REVISION
REVISION # DATE
2 2/03/21

DETAIL #: CI-TL-09-KSV
3" EXTRUSIONS
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

TWO PIECE OPENING 4" TWO PIECE OPENING


EXTRUSION CAP EXTRUSION BASE
PART # 2-0215 PART # 2-4266

PARAPET EXTRUSION
PART # 2-1598

OPTIONAL WIPER
GASKET
(FIELD INSTALLED)

4" CORNER
FEMALE EXTRUSION 4" PANEL BASE "B"
PART # 2-4044 EXTRUSION
PART # 2-4052
4" CORNER
MALE EXTRUSION
PART # 2-4001

SILL EXTRUSION
PART # 2-4064

TWO PIECE STACK JOINT 4" STACK JOINT


MALE EXTRUSION FEMALE EXTRUSION
DIE #2-4070 PART # 2-4067

REVISION
REVISION # DATE
2 2/03/21

DETAIL #: CI-TL-10-KSV
4" EXTRUSIONS
RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION

LAP STRIP FOR TWO PIECE


JAMB EXTRUSION LAP STRIP FOR PARAPET EXTRUSION

LAP STRIPS FOR OUTSIDE CORNER LAP STRIPS FOR INSIDE CORNER
EXTRUSION EXTRUSION

REVISION
REVISION # DATE
LAP STRIP FOR "J" BASE EXTRUSION 0 01/01/21

DETAIL #: CI-TL-11-KSV
EXTRUSION LAP
STRIPS RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca
KS SERIES - VERTICAL INSTALLATION
FIELD CUT/NOTCH JAMB
SEALANT END DAM EXTRUSION AT HEAD AND
JAMB (NOT BY KINGSPAN)
3
TWO PIECE HEAD
EXTRUSION CAP
EXPOSED SEALANT
(NOT BY KINGSPAN)

N
S IO
RU
XT
ADE
E

TWO PIECE JAMB EXTRUSION


CEH
PIE
O
TW 4
TWO PIECE JAMB
EXTRUSION CAP
2
TWO PIECE HEAD EXTRUSION BASE W/
FIELD DRILL 3 8" Ø WEEP HOLES
(NOT BY KINGSPAN)
1
TWO PIECE JAMB
EXTRUSION BASE
6
EXPOSED SEALANT FIELD CUT/NOTCH JAMB
(NOT BY KINGSPAN) EXTRUSION
(NOT BY KINGSPAN)

5
TWO PIECE JAMB
I ON EXTRUSION CAP
RUS
XT
LE
SIL EXTRUSION INSTALLATION SEQUENCE:
1 TWO PIECE JAMB EXTRUSION BASE
2 TWO PIECE HEAD EXTRUSION BASE
3 TWO PIECE HEAD EXTRUSION CAP
4 TWO PIECE JAMB EXTRUSION CAP
5 SILL EXTRUSION
6 EXTERIOR SEALANTS AS REQUIRED

REVISION
REVISION # DATE
0 01/01/21

DETAIL #: CI-TL-12-KSV
EXTRUSION AT
FRAMED OPENING RELEASE: 2021 www.kingspanpanels.us
www.kingspanpanels.ca

You might also like