You are on page 1of 180

Introduction

!
This section includes updated information, added since it was first
published in December 2015.
Section Last updated
Introduction 12/08/2019
GypWall classic 08/02/2021
GypWall robust 06/12/2019
GypWall extreme 06/12/2019
GypWall quiet sf 10/06/2019
GypWall staggered 10/06/2019
GypWall quiet 10/06/2019
GypWall quiet iwl 06/12/2019
GypWall audio 08/02/2021
GypWall rapid dB Plus REMOVED 16/03/2020
Non-loadbearing timber stud 08/02/2021

Partitions
CO4

Partitions
C04
Introduction

Partitions
This section contains a full range of lightweight partition and wall
systems for use in new and existing buildings. They cover all applications,
from simple space division to high performance walls
Partitions
C04
Introduction
Partitions
British Gypsum offers a full range of lightweight
partition and wall systems. Our systems are
non-loadbearing and constructed using modern,
drylining techniques. British Gypsum metal
framed partitions and walls can be used in all
types of new and existing buildings, including
private and social housing, apartments,

Partitions
healthcare, educational facilities, recreational
and industrial properties.

C04
They cover all applications, from simple space
division, through to high performance walls
designed to meet the most demanding fire
resistance, sound insulation, impact and height
requirements.

British Gypsum partition systems are constructed


using lightweight materials, which can give rise to
significant savings in structural design compared
to masonry alternatives. Big benefits also include
the speed of installation and reduction to overall
build costs.

Buildings need to evolve throughout their life to


suit changing demands placed upon them. Our
lightweight partition systems are easy to reconfigure
with minimal impact to both building and occupants
resulting in less disruption, optimising the
transformation process.

You may also be interested in...


For unique performance situations with specialist requirements:
— Curved partitions — Access to build from one side only
— High levels of fire resistance — High security including bomb blast

Refer to C05. S01. P02 – Specialist partitions

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S01. P02


Partitions
Introduction

When specifying partitions, a number of performance characteristics are normally used to determine the required solution.
Depending on the project or construction type, these performance parameters could be set by minimum regulatory
standards, or a client or customer requirement for buildings that offer the highest standards of performance and comfort.

Our quick-reference partition system guide, below, allows you to simply select the performance categories of interest and
identify the British Gypsum partitions systems that best satisfy your project requirements.

Duty Maximum
Fire rating height1
Partition
Acoustic performance
performance thickness System Page
Partitions

mins mm Rw dB Rw + Ctr dB BS 5234 mm

Medium -
30 - 120 75 - 211 34 - 63 47 - 57 8100 GypWall classic C04.S02.P02
Severe
C04

60 - 120 102 - 132 42 - 58 - Severe 4900 GypWall robust C04.S03.P02

GypWall extreme (including


30 - 60 97 - 203 44 - 62 - Severe 7800 C04.S04.P02
exreme / robust Hybrid)

60 - 120 137 - 238 61 - 65 53 - 59 Severe 6800 GypWall quiet sf C04.S05.P02

Heavy -
30 - 90 102 - 208 49 - 63 48 - 55 5700 GypWall staggered C04.S06.P02
Severe

60 - 120 200 - 300 60 - 64 47 - 58 Severe 7500 GypWall quiet C04.S07.P02

60 - 120 ≥200 66 - 70 58 - 62 Severe 3900 GypWall quiet iwl C04.S08.P02

60 - 120 300 - 800 67 - 80 56 - 71 Severe 11500 GypWall audio C04.S09.P02

30 75 - 102 40 - 46 - Medium 2700 GypWall rapid dB Plus C04.S10.P02

Non-loadbearing timber
30 - 120 88 - 196 34 - 52 - - - C04.S11.P02
stud (internal partitions)

Non-loadbearing timber
60 - 90 141 - 293 56 - 63 48 - 53 - - C04.S11.P05
stud (separating walls)

1
Based on studs at 600mm centres

Additional information
Try out The White Book System Selector, an online tool designed to help find the ideal solutions for your
project needs. Additional information such as BIM data (Revit), NBS clauses, CAD drawings and other
associated items can be downloaded. Visit british-gypsum.com

C04. S01. P03 british-gypsum.com


GypWall performance

Introduction
Acoustic performance
Table 1 — Sound insulation performance for residential specification
On-site Laboratory2
Approved Document E (England and Wales) Minimum solution Recommended solution
DnT,w + Ctr dB
(Rw + Ctr ) dB (Rw + Ctr ) dB

Separating walls between new homes 45 (49) (54)


Separating walls between purpose-built rooms for residential
43 (47) (52)
purposes and rooms created by a change of use or conversion

On-site Laboratory2

Partitions
Technical Standards Section 5 (Scotland) Minimum solution Recommended solution
DnT,w + Ctr dB
Rw dB Rw dB

Separating walls between new homes, purpose-built for residential


56 60 63
purposes and conversions (not including traditional buildings1)

Separating walls between rooms created by a change of use


53 57 60

C04
or conversion (traditional buildings1)

1
Definition of traditional buildings - A building or part of a building of a type constructed before or around 1919:
a) using construction techniques that were commonly in use before 1919; and
b) with permeable components, in a way that promotes the dissipation of moisture from the building fabric.
2
Minimum solutions provide little or no margin of safety to allow for reduction in performance due to flanking transmission. Recommended solutions have
greater potential to satisfy the requirements of Building regulations.

Good practice specification guidance


British Gypsum’s systems are designed and tested to meet — Consider flanking transmission at the design stage and
every performance requirement and are fully supported by ensure construction detailing is specified to eliminate,
our SpecSure® lifetime system warranty. or at least to minimise, any downgrading of the acoustic
performance
This means that when our systems are installed following
— Small openings such as gaps, cracks or holes will conduct
our guidance they will achieve every performance claim we
airborne sounds and can significantly reduce the sound
make, and if they don’t then we’ll put it right.
insulation of a construction. For optimum sound
insulation a construction must be airtight
To maximise the performance achieved on site, consider the
following good practice specification guidance: — When designing the layout of rooms requiring separation
by sound insulating walls abutting structural steelwork,
consideration should be given to the potential loss of
sound insulation performance through the steelwork
— Deflection heads, by definition, must be able to move
and, therefore, achieving an airtight seal is very difficult
without incorporating sophisticated components and
techniques. Air leakage at the partition heads will have a
detrimental effect on acoustic performance of any
partition. Where acoustic performance is a key
consideration, steps must be taken to minimise this loss
of performance
— A common mistake made when designing a building is to
specify a high performance element and then incorporate
a lower performing element within it; for example, a
door within a partition. Where the difference between
insulation is relatively small (7dB or less), there needs
to be a comparatively large area of the lower insulation
element before the overall sound insulation is
significantly affected. However, where there is a greater
difference in sound insulation performance between
the two elements, this would usually result in a greater
reduction of overall sound insulation performance

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S01. P04


Standard GypWall performance
Introduction

Table 2 – GypWall classic metal stud partition recommended maximum heights (mm) - based on a limiting deflection of L/240 at
200Pa. Applicable to non fire-rated or BS 476: Part 22 fire-rated constructions only (not applicable to EN 1364-1)
Stud Boarding 600mm 600mm 400mm 400mm 300mm 300mm
each side centres boxed centres boxed centres boxed
48 S 50 1 x 12.5mm 2500 2800 2900 3200 3100 3500
1 x 15mm 2800 3000 3100 3300 3300 3600
2 x 12.5mm 3400 3600 3600 3800 3800 4000
2 x 15mm 3700 3800 3900 4000 4000 4200
48 I 50 1 x 12.5mm 2900 - 3400 - 3700 -
1 x 15mm 3100 - 3500 - 3800 -
Partitions

2 x 12.5mm 3700 - 3900 - 4200 -


2 x 15mm 3900 - 4200 - 4400 -
60 S 50 1 x 12.5mm 3200 3400 3500 3800 3800 4200
1 x 15mm 3400 3600 3700 4000 4000 4300
C04

2 x 12.5mm 4100 4300 4300 4600 4600 4800


2 x 15mm 4400 4500 4600 4800 4800 5000
60 I 50 1 x 12.5mm 3600 - 4000 - 4400 -
1 x 15mm 3800 - 4200 - 4500 -
2 x 12.5mm 4400 - 4700 - 5000 -
2 x 15mm 4600 - 4900 - 5200 -
60 I 70 1 x 12.5mm 4100 - 4600 - 5000 -
1 x 15mm 4200 - 4700 - 5100 -
2 x 12.5mm 4700 - 5100 - 5500 -
2 x 15mm 4900 - 5300 - 5600 -
70 S 50 1 x 12.5mm 3600 3900 4000 4300 4300 4700
1 x 15mm 3800 4100 4200 4500 4500 4900
2 x 12.5mm 4600 4800 4900 5100 5100 5400
2 x 15mm 4900 5100 5100 5300 5300 5600
70 S 60 1 x 12.5mm 3800 4100 4200 4600 4500 5000
1 x 15mm 4000 4300 4400 4700 4700 5100
2 x 12.5mm 4700 4900 5000 5300 5200 5600
2 x 15mm 5000 5200 5200 5500 5500 5800
70 AS 50 1 x 12.5mm 3800 4200 4300 4700 4600 5100
1 x 15mm 4000 4400 4500 4800 4700 5200
2 x 12.5mm 4700 5000 5000 5300 5300 5700
2 x 15mm 5000 5200 5300 5600 5500 5900
70 I 50 1 x 12.5mm 4100 - 4600 - 5000 -
1 x 15mm 4300 - 4700 - 5100 -
2 x 12.5mm 4900 - 5300 - 5600 -
2 x 15mm 5200 - 5500 - 5800 -
70 I 70 1 x 12.5mm 4600 - 5100 - 5600 -
1 x 15mm 4700 - 5300 - 5700 -
2 x 12.5mm 5300 - 5700 - 6100 -
2 x 15mm 5500 - 5900 - 6300 -
92 S 50 1 x 12.5mm 4500 4800 4900 5400 5300 5800
1 x 15mm 4700 5100 5200 5600 5500 6000
2 x 12.5mm 5700 5900 6000 6300 6200 6600
2 x 15mm 5900 6100 6200 6500 6400 6800

In all GypWall classic systems, it is recommended that for heights between 4200mm and 8000mm, the Gypframe Deep Flange Floor & Ceiling Channel is
used. Gypframe Extra Deep Flange Floor & Ceiling Channel is used for heights above 8000mm. Additional consideration needs to be given if there is a deflection
head requirement.

For the affect on acoustic performance refer to C02. S01. P30.

C04. S01. P05 british-gypsum.com


Standard GypWall performance (continued)

Introduction
Table 2 (continued) – GypWall classic metal stud partition recommended maximum heights (mm) - based on a limiting
deflection of L/240 at 200Pa. Applicable to non fire-rated or BS 476: Part 22 fire-rated constructions only (not applicable to
EN 1364-1)
Stud Boarding 600mm 600mm 400mm 400mm 300mm 300mm
each side centres boxed centres boxed centres boxed
92 S 60 1 x 12.5mm 4700 5000 5200 5600 5600 6100
1 x 15mm 4900 5300 5400 5800 5800 6300
2 x 12.5mm 5800 6000 6100 6500 6500 6900
2 x 15mm 6000 6200 6300 6700 6600 7000
92 AS 50 1 x 12.5mm 4700 5100 5200 5700 5700 6200

Partitions
1 x 15mm 4900 5300 5400 5700 5800 6400
2 x 12.5mm 5800 6100 6200 6500 6500 6900
2 x 15mm 6000 6300 6400 6700 6700 7000
92 S 10 1 x 12.5mm 5300 5800 6000 6600 6500 7200
1 x 15mm 5500 6000 6100 6700 6600 7300

C04
2 x 12.5mm 6200 6600 6700 7200 7200 7700
2 x 15mm 6400 6800 6900 7400 7300 7800
92 I 90 1 x 12.5mm 6000 - 6800 - 7400 -
1 x 15mm 6200 - 6900 - 7500 -
2 x 12.5mm 6800 - 7400 - 7900 -
2 x 15mm 6900 - 7500 - 8000 -
146 S 50 1 x 12.5mm 6200 6800 6900 7600 7500 8300
1 x 15mm 6500 7000 7200 7800 7700 8400
2 x 12.5mm 7600 8000 8100 8600 8500 9100
2 x 15mm 7900 8200 8300 8800 8700 9300
146 AS 50 1 x 12.5mm 6600 7100 7300 8000 8000 8800
1 x 15mm 6800 7400 7600 8200 8200 8900
2 x 12.5mm 7800 8200 8400 8900 8900 9500
2 x 15mm 8100 8500 8600 9100 9100 9700
146 I 80 1 x 12.5mm 7900 - 8900 - 9700 -
1 x 15mm 8100 - 9000 - 9800 -
2 x 12.5mm 8800 - 9600 - 10400 -
2 x 15mm 9000 - 9800 - 10500 -
146 TI 90 1 x 12.5mm 8300 - 9400 - 10300 -
1 x 15mm 8400 - 9500 - 10400 -
2 x 12.5mm 9200 - 10100 - 10900 -
2 x 15mm 9400 - 10300 - 11100 -

In all GypWall classic systems, it is recommended that for heights between 4200mm and 8000mm, the Gypframe Deep Flange Floor & Ceiling Channel is
used. Gypframe Extra Deep Flange Floor & Ceiling Channel is used for heights above 8000mm. Additional consideration needs to be given if there is a deflection
head requirement.

For the affect on acoustic performance refer to C02. S01. P30.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S01. P06


Standard GypWall construction details
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

1 1a

1
3
5

5
Partitions

300mm
2
600mm

600mm

600mm
C04

2
300mm

6
7

Stud splicing detail Fully boxed Gypframe 'C' Stud

2 2a
Centres
at 600mm
Centres
at
thereafter
600mm
thereafter

1479mm
1479mm

50mm

50mm

50mm

75mm 75mm 75mm 75mm 75mm 28mm 28mm 28mm


38mm
38mm

38mm
30mm

38mm
879mm

879mm
279mm

279mm

70mm 92mm 146mm

48mm 60mm 70mm 146mm 70mm 92mm 146mm


92mm
stud stud stud stud AcouStud AcouStud AcouStud
stud

Service cut-outs - Gypframe ‘C’ and Gypframe ‘I’ Studs Service cut-outs - Gypframe AcouStuds

1 Gypframe 'I' Stud 5 British Gypsum Wafer Head Drywall Screws or


British Gypsum Wafer Head Jack-Point Screws
2 Gypframe 'C' Stud
6 Crimp
3 Gypframe AcouStud
7 Studs offset at top and bottom to facilitate engagement into channels
4 Gypframe Floor & Ceiling Channel

C04. S01. P07 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

3 3a

Partitions
11
4

3 6

3
1

C04
2 7

Base with timber sole plate

6
4

10

Head and base Junction with masonry and stop end detail

1 Gyproc plasterboard or Glasroc F specialist board 7 Floating screed on resilient layer


2 Gypframe 'C' Stud 8 Timber sole plate suitably fixed to structure
3 Gypframe Floor & Ceiling Channel 9 Internal blockwork
4 Gyproc Sealant 10 DriLyner basic wall lining system
5 Bulk fill Gyproc jointing materials (where gap exceeds 5mm) 11 Isover insulation
6 Skirting

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S01. P08


Standard GypWall construction details (continued)
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

5 6

2 1

3
Partitions

‘T’ Junction when partition with higher acoustic performance abuts


C04

a partition with lower acoustic performance. Acoustic principles


‘T’ junction - single layer only - detail may not be suitable for all solutions

7a 7b

2 2
1
1
4

3
3

‘T’ junction to optimise acoustic performance and reduce ‘T’ junction to optimise acoustic performance and reduce
flanking transmission flanking transmission

8 9

2 1

1
5

2
3

Four way junction to optimise acoustic performance and


reduce flanking transmission Splayed corner

1 Gyproc plasterboard or Glasroc F specialist board 4 Gypframe GA5 Internal Fixing Angle
2 Gypframe 'C' Stud 5 Gypframe GA6 Splayed Angle
3 Isover insulation

Guidance must be sought from the relevant approval authority e.g. Building Control to establish if a cavity barrier is required (Approved Document B)

C04. S01. P09 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

10 11

1
1

2
2

Partitions
Corner detail - single layer Corner detail - double layer

C04
12 13

16
mm
12 12
mm mm
2

3
1

1
4

Gypframe 99 FC 50 Fixing Channel


Typical control joint (short legs flattened at stud positions)

14

Gypframe Service Support Plate

1 Gyproc plasterboard or Glasroc F specialist board 5 Gypframe 99 FC 50 Fixing Channel


2 Gypframe 'C' Stud 6 18mm plywood
3 Stone mineral wool (minimum density 23kg/m3) (by others) 7 Gypframe Service Support Plate
4 Gyproc Control Joint

Installing the screw into the side of the Gypframe Service Support Plate and the web of the Gypframe 'C' Stud will avoid creating excessive distortion to
the lining board.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S01. P10


Standard GypWall construction details (continued)
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

15
15mm 7 16 15mm 7
15mm 6 15mm 6

4 4
20mm 15mm 10

3
11
2
1 2
1
Partitions

Deflection head for 15mm downward movement Deflection head for 15mm downward movement and up
and 60 minutes fire resistance to BS 476-22 and BS EN 1364-1 to 120 minutes fire resistance to BS 476-22 and BS EN 1364-1

Not suitable for 60 minutes single layer systems to BS EN 1364-1 Not suitable for 48mm studs to BS EN 1364-1
C04

17 7 18
7
25mm 50mm
8 8

7
25mm 7 50mm

5 5

55mm
30mm

3
3
2
2
1
1

Deflection head for plus or minus 25mm movement Deflection head for 50mm downward movement
and 60 minutes fire resistance to BS 476-22 only and 60 minutes fire resistance to BS 476-22 only

19 20 7
7
25mm 9
50mm
9
7
25mm 7
50mm
5 5

30mm
3 55mm

3
2 2
1 1

Deflection head for plus or minus 25mm movement Deflection head for 50mm downward movement
and 60 minutes fire resistance to BS 476-22 only and 60 minutes fire resistance to BS 476-22 only

1 Gyproc plasterboard or Glasroc F specialist board 7 Gyproc FireStrip (continuous)


2 Gypframe 'C' Stud 8 Timber head plate suitably fixed to structure
3 Gypframe GFS1 Fixing Strap 9 25mm Glasroc F firecase
4 Gypframe Deep Flange Floor & Ceiling Channel 10 Stone mineral wool (by others)
5 Gypframe Extra Deep Flange Floor & Ceiling Channel 11 Nogging cut from Gypframe 'C' Stud
6 Gyproc CoreBoard

No fixings should be made through the boards into the flanges of the head channel. The arrow ( ) denotes the position of the uppermost board fixing,
which should be made into Gypframe GFS1 Fixing Strap (or stud nogging in construction detail 16). Continuous Gyproc FireStrip must be installed as shown to
maintain fire performance. Where there is a need for a deflection head in a 90 minute wall, the 120 minute solution can be used (refer to construction detail 16)
or alternatively, please contact the British Gypsum Technical Advice Centre for further guidance.
To minimise loss in acoustic performance refer to C02 S01 P10 Acoustic performance of head details.

C04. S01. P11 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

21 11 22 11
6 6
8 9
5 5

15mm

25mm
15mm
Stud top

25mm
4 4

Stud top

Partitions
15mm

7 7

25mm
10 10

C04
1 12
2 2
3 3

Deflection head 15mm downward movement Deflection head 25mm downward movement
30 minutes fire resistance depending on specification 60 minutes fire resistance depending on specification
BS 476: Part 22: 1987 and BS EN 1364-1 BS 476: Part 22: 1987

23 24
11 11
6 6
8 9
5 5

15mm
25mm
15mm
Stud top

25mm

4
Stud top

4
15mm

Deflection Head
Deflection Head
25mm

15mm Downward Movement 14


30 or 60 Minutes Fire Resistance Depending on Specification15 25mm Downward Movement 14
BS 476: Part 22: 1987 10
30 or 60 Minutes Fire Resistance Depending on Specification
15
30 Minutes Fire Resistance BS EN 1364-1: 1999 BS 476: Part 22: 1987 and BS EN 1364-1: 1999
10
13
16
2
2
3
3

Deflection head 15mm downward movement Deflection head 25mm downward movement
90 minutes fire resistance depending on specification 120 minutes fire resistance depending on specification
BS 476: Part 22: 1987 and BS EN 1364-1 BS 476: Part 22: 1987

1 12.5mm Gyproc WallBoard 9 15mm Glasroc F firecase


2 Gypframe 70 S 50 'C' Stud 10 Gypframe Steel Angle
3 Isover insulation (if required) 11 Gypframe GA4 Steel Angle (if required for acoustic performance)
4 Gypframe 72 DC 60 Deep Flange Floor & Ceiling Channel 12 15mm Gyproc FireLine
5 Gyproc Sealant 13 15mm Gyproc SoundBloc
6 Gyproc FireStrip 14 Gypframe 70 S 50 'C' Stud or 72 FEC 50 Channel noggings
7 Gypframe GFS1 Fixing Channel 15 Stone mineral wool 33kg/m3 (by others)
8 19mm Gyproc CoreBoard 16 12.5mm Gyproc FireLine

No fixings should be made through the boards into the flanges of the head channel.

Deflection Head Deflection Head


0115 Downward
15mm 945 6123 Movement
bgtechnical.enquiries@bpb.com C04. S01. P12
25mm Downward Movement
90 or 120 Minutes Fire Resistance Depending on Specification
90 or 120 Minutes Fire Resistance Depending on Specification
BS 476: Part 22: 1987
Standard GypWall construction details (continued)
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

25
Partitions

150mm
4
C04

1200mm 1200mm

Door frame (maximum 1200mm width) to satisfy BS 5234: Parts 1 & 2: 1992 - Light and Medium Duty (up to 35kg door)

1 Gyproc plasterboard or Glasroc F specialist board 5 Timber door frame and architrave
2 Gypframe 'C' Stud 6 Gypframe 'C' Stud to maintain stud module
3 Gypframe Floor & Ceiling Channel 7 Timber sub-frame
4 Gypframe Floor & Ceiling Channel cut and bent to form door head

Advice should be sought from the door manufacturer prior to the construction of these details.

C04. S01. P13 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

26

150mm

Partitions
4

C04
3

2
300mm

1200mm 1200mm

150mm

Door frame (maximum 1200mm width) to satisfy BS 5234: Parts 1 & 2: 1992 - Heavy and Severe Duty (up to 60kg door)

1 Gyproc plasterboard or Glasroc F specialist board 5 Timber door frame and architrave
2 Gypframe 'C' Stud 6 Gypframe 'C' Stud to maintain stud module
3 Gypframe Floor & Ceiling Channel to sleeve studs 7 Gypframe Floor & Ceiling Channel cut and bent to extend up studs
4 Gypframe Floor & Ceiling Channel cut and bent to form door head

Advice should be sought from the door manufacturer prior to the construction of these details.

At the base, the channel is cut and bent to extend 300mm up the studs and fixed each side with two British Gypsum Wafer Head Drywall Screws. The
studs each side of the opening are sleeved full height of opening with Gypframe Floor & Ceiling Channel.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S01. P14


Standard GypWall construction details (continued)
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

27

8
7
Partitions

150mm
4
C04

2
300mm

1200mm 1200mm 1200mm

150mm

Alternative door frame for fixed partition heads only (maximum 1200mm width) to satisfy
BS 5234: Parts 1 & 2: 1992 - Heavy and Severe Duty (up to 60kg door)

1 Gyproc plasterboard or Glasroc F specialist board 6 Gypframe 'C' Stud to maintain stud module
2 Gypframe 'C' Stud 7 Gypframe 'C' Studs fixed back to back with
British Gypsum Drywall Screws at 300mm centres staggered
3 Gypframe Floor & Ceiling Channel to sleeve studs
8 Plasterboard infill (same type as lining) cut to fit between studs
4 Gypframe Floor & Ceiling Channel cut and bent to form door head
9 Gypframe Floor & Ceiling Channel cut and bent to extend up studs
5 Timber door frame and architrave

Advice should be sought from the door manufacturer prior to the construction of these details.

At the base, the channel is cut and bent to extend 300mm up the studs and fixed each side with two British Gypsum Wafer Head Drywall Screws.
The studs each side of the opening are sleeved full height of opening with Gypframe Floor & Ceiling Channel.
The principle of this alternative detail is only suitable for GypWall classic, GypWall robust and GypWall extreme for fixed head situations only.

C04. S01. P15 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

28

3
1

Partitions
150mm
4

C04
5

150mm

Openings 1201 - 3300mm wide, for example double doors or large windows

1 Gypframe 'C' Stud 6 Centre stud required for margin up to 600mm between openings
2 Stud sleeved to full opening height with Gypframe Floor & Ceiling Channel 7 Partition between openings, minimum 600mm for Gypframe 'C' Studs
3 Gypframe studs (appropriate to system) (minimum 300mm for Gypframe 'I' Studs)

4 Gypframe Extra Deep Flange Floor & Ceiling Channel 8 Maximum distance 2400mm (if exceeds 2400mm contact British Gypsum
Technical Advice Centre)
5 Gypframe stud insert

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S01. P16


Standard GypWall construction details (continued)
Introduction

To be read in conjunction with system specific details. Refer to relevant system sections

29 30

Elevation

4
X

Y
Partitions

2
C04

2
Section X - X

1
Fire tested construction in which the damper is supported
3 by the partition (isometric view)

4 31

150mm
6
Section Y - Y

Opening for service penetrations in fire-rated partitions Opening up to 600mm wide for services

1 Gyproc plasterboard or Glasroc F specialist board 5 Damper (by others). Weight of damper should not exceed 57kg.
2 Gypframe 'C' Stud Size of damper should not exceed 1400 x 1200mm

3 Gypframe Floor & Ceiling Channel 6 Gypframe Folded Edge Standard Floor & Ceiling Channel cut and bent
to form opening head and cill
4 Penetration seal if required (refer to damper manufacturer for details)

C04. S01. P17 british-gypsum.com


Standard GypWall construction details (continued)

Introduction
To be read in conjunction with system specific details. Refer to relevant system sections

32

Partitions
5

C04
2

Board layout - typical configuration

33 34

2 6

7 7

Horizontal board joint - double layer Horizontal board joint - single layer

1 Inner layer of Gyproc plasterboard or Glasroc F specialist board 5 British Gypsum Drywall Screws
2 Outer layer of Gyproc plasterboard or Glasroc F specialist board 6 Gyproc plasterboard or Glasroc F specialist board
3 Gypframe GFS1 Fixing Strap 7 Gypframe 'C' Stud
4 Gypframe metal framing 8 Gypframe GFT1 Fixing T (alternatively use Gypframe GSF1 Fixing Strap)

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S01. P18


GypWall classic

GypWall classic
A highly versatile metal stud partition system

All our systems are covered by SpecSure® when using


genuine British Gypsum and Saint-Gobain Isover products
Partitions
C04
GypWall classic
GypWall classic
GypWall classic is the industry’s original 30 120
lightweight non-loadbearing drywall partition mins

system, providing cost-effective, multi-purpose


solutions suitable for all types of buildings.
34 63
Key benefits Rw dB

— Wide range of performances achievable

Partitions
through a combination of interchangeable
Gyproc plasterboards, Gypframe metal,
System can be skim
Thistle finish plasters and Saint-Gobain Isover finished with
ThistlePro PureFinish.
insulation

C04
Refer to C02. S01. P49

— Optimised acoustic performance for a given


footprint through the use of Gypframe AcouStuds
— Quick to install compared to masonry or timber Refer to C01. S01. P07

frame alternatives and allows transformation


of building layouts with minimal disruption
— Non-hygroscopic Gypframe metal framework
will not twist, warp or rot
— Easy accommodation of services within the
stud cavity due to pre-cut service holes within
the Gypframe metal studs

You may also be interested in...


GypWall robust
Need a higher Duty Rating to BS 5234? GypWall robust provides Severe Duty Rating with a single
layer of board.
Refer to C04. S03. P02.

ShaftWall
Where access is limited to one side only, for example risers, lift shafts, corridors and stair cores,
ShaftWall provides the answer.
Refer to C05. S02. P02.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P02


GypWall classic performance
GypWall classic

For details of when


to specify fire
48mm Gypframe 'C' Studs - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 1a — Solutions to satisfy the requirements of BS EN 1364-1

1 2

One layer of board each side of 48mm One layer of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04

finish only finish only

30 minutes fire resistance

1 75 Gyproc WallBoard 1 x 12.5 2500 34 - Medium 18 A206001 -

1 75 Glasroc H tilebacker 1 x 12.5 2500 34 - Medium 22 H206001 -

1 75 Gyproc SoundBloc 1 x 12.5 2500 37 - Medium 22 A206152 -

2 75 Gyproc WallBoard 1 x 12.5 2500 40 - Medium 18 A206033 -

2 75 Glasroc H tilebacker 1 x 12.5 2500 40 - Medium 22 H206033 -

2 75 Gyproc SoundBloc 1 x 12.5 2500 43 - Medium 22 A206184 -

1 80 Gyproc WallBoard 1 x 15 2800 36 - Medium 22 A206002 -

1 80 Gyproc SoundBloc 1 x 15 2800 39 - Medium 26 A206153 -

2 80 Gyproc WallBoard 1 x 15 2800 42 - Medium 22 A206034 -

2 80 Gyproc SoundBloc 1 x 15 2800 44 45 Medium 26 A206185 A206185S

60 minutes fire resistance

1 75 Glasroc F multiboard 1 x 12.5 2500 36 - Severe 25 G106010 -

1 80 Gyproc FireLine 1 x 15 2800 36 - Heavy 24 A206066 -

1 80 Gyproc SoundBloc f 1 x 15 2800 39 - Heavy 27 A206299 -

2 80 Gyproc FireLine 1 x 15 2800 42 - Heavy 24 A206098 -

2 80 Gyproc SoundBloc f 1 x 15 2800 44 45 Heavy 27 A206300 A206300S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P03 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
48mm Gypframe 'C' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 1b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3

One layer of board each side of 48mm One layer of board each side of 48mm One layer of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3

C04
finish only finish only

30 minutes fire resistance

1 75 Gyproc WallBoard 1 x 12.5 2500 34 - Medium 18 A206001 -

1 75 Glasroc H tilebacker 1 x 12.5 2500 34 - Medium 22 H206001 -

1 75 Gyproc SoundBloc 1 x 12.5 2500 37 - Medium 22 A206152 -

2 75 Gyproc WallBoard 1 x 12.5 2500 40 - Medium 18 A206033 -

2 75 Glasroc H tilebacker 1 x 12.5 2500 40 - Medium 22 H206033 -

2 75 Gyproc SoundBloc 1 x 12.5 2500 43 - Medium 22 A206184 -

1 80 Gyproc WallBoard 1 x 15 2800 36 - Medium 22 A206002 -

1 80 Gyproc SoundBloc 1 x 15 2800 39 - Medium 26 A206153 -

2 80 Gyproc WallBoard 1 x 15 2800 42 - Medium 22 A206034 -

2 80 Gyproc SoundBloc 1 x 15 2800 44 45 Medium 26 A206185 A206185S

60 minutes fire resistance

1 75 Glasroc F multiboard 1 x 12.5 2500 36 - Severe 25 G106010 -

1 80 Gyproc FireLine 1 x 15 2800 36 - Heavy 24 A206066 -

1 80 Gyproc SoundBloc f 1 x 15 2800 39 - Heavy 27 A206299 -

2 80 Gyproc FireLine 1 x 15 2800 42 - Heavy 24 A206098 -

2 80 Gyproc SoundBloc f 1 x 15 2800 44 45 Heavy 27 A206300 A206300S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P04


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
70mm Gypframe 'C' Studs - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 2a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

One layer of board each side of One layer of board each side of 70mm One layer of board each side of 70mm
70mm Gypframe ‘C’ Studs at 600mm Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
centres. Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
C04

Any2 Skim3 Any2 Skim3


finish only finish only

30 minutes fire resistance

1 97 Gyproc WallBoard 1 x 12.5 3600 36 - Medium 18 A206013 -

1 97 Glasroc H tilebacker 1 x 12.5 3600 36 - Medium 22 H206013 -

1 97 Gyproc SoundBloc 1 x 12.5 3600 40 - Medium 22 A206164 -

2 97 Gyproc WallBoard 1 x 12.5 3600 42 - Medium 18 A206045 -

2 97 Glasroc H tilebacker 1 x 12.5 3600 42 - Medium 22 H206045 -

3 97 Gyproc WallBoard 1 x 12.5 3600 43 - Medium 19 A206138 -

3 97 Glasroc H tilebacker 1 x 12.5 3600 43 - Medium 23 H206138 -

2 97 Gyproc SoundBloc 1 x 12.5 3600 45 - Medium 22 A206196 -

3 97 Gyproc SoundBloc 1 x 12.5 3600 47 - Medium 22 A206228 -

1 102 Gyproc WallBoard 1 x 15 3800 38 39 Medium 22 A206014 A206014S

1 102 Gyproc SoundBloc 1 x 15 3800 42 - Heavy 26 A206165 -

2 102 Gyproc WallBoard 1 x 15 3800 43 44 Medium 22 A206046 A206046S

3 102 Gyproc WallBoard 1 x 15 3800 44 45 Medium 22 A206139 A206139S

2 102 Gyproc SoundBloc 1 x 15 3800 47 48 Heavy 26 A206197 A206197S

60 minutes fire resistance

1 102 Gyproc FireLine 1 x 15 3800 37 - Heavy 24 A206078 -

1 102 Gyproc SoundBloc f 1 x 15 3800 42 - Heavy 27 A206301 -

2 102 Gyproc FireLine 1 x 15 3800 43 44 Heavy 24 A206110 A206110S

3 102 Gyproc FireLine 1 x 15 3800 44 45 Heavy 24 A206141 A206141S

2 102 Gyproc SoundBloc f 1 x 15 3800 47 48 Heavy 27 A206302 A206302S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P05 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
70mm Gypframe 'C' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 2b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3

One layer of board each side of 70mm One layer of board each side of 70mm One layer of board each side of 70mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty rating Approx. System reference
thickness type thickness height1 Rw dB weight
mm mm mm kg/m²

C04
Any2 Skim3 Any32 Skim3
finish only finish only

30 minutes fire resistance

1 97 Gyproc WallBoard 1 x 12.5 3600 36 - Medium 18 A206013 -

1 97 Glasroc H tilebacker 1 x 12.5 3600 36 - Medium 22 H206013 -

1 97 Gyproc SoundBloc 1 x 12.5 3600 40 - Medium 22 A206164 -

2 97 Gyproc WallBoard 1 x 12.5 3600 42 - Medium 18 A206045 -

2 97 Glasroc H tilebacker 1 x 12.5 3600 42 - Medium 22 H206045 -

3 97 Gyproc WallBoard 1 x 12.5 3600 43 - Medium 19 A206138 -

3 97 Glasroc H tilebacker 1 x 12.5 3600 43 - Medium 23 H206138 -

2 97 Gyproc SoundBloc 1 x 12.5 3600 45 - Medium 22 A206196 -

3 97 Gyproc SoundBloc 1 x 12.5 3600 47 - Medium 22 A206228 -

1 102 Gyproc WallBoard 1 x 15 3800 38 39 Medium 22 A206014 A206014S

1 102 Gyproc SoundBloc 1 x 15 3800 42 - Heavy 26 A206165 -

2 102 Gyproc WallBoard 1 x 15 3800 43 44 Medium 22 A206046 A206046S

3 102 Gyproc WallBoard 1 x 15 3800 44 45 Medium 22 A206139 A206139S

2 102 Gyproc SoundBloc 1 x 15 3800 47 48 Heavy 26 A206197 A206197S

60 minutes fire resistance

1 102 Gyproc FireLine 1 x 15 3800 37 - Heavy 24 A206078 -

1 102 Gyproc SoundBloc f 1 x 15 3800 42 - Heavy 27 A206301 -

2 102 Gyproc FireLine 1 x 15 3800 43 44 Heavy 24 A206110 A206110S

3 102 Gyproc FireLine 1 x 15 3800 44 45 Heavy 24 A206141 A206141S

2 102 Gyproc SoundBloc f 1 x 15 3800 47 48 Heavy 27 A206302 A206302S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P06


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
70mm Gypframe AcouStuds - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 3a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3 4

One layer of board each side of One layer of board each side of 70mm One layer of board each side of One layer of board each side of
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at 70mm Gypframe 70 AS 50 AcouStuds 70mm Gypframe 70 AS 50 AcouStuds at
600mm centres. Linings as in table. 600mm centres. 25mm Isover Acoustic at 600mm centres. 50mm 600mm centres. 3 x 25mm
Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04

finish only finish only

30 minutes fire resistance

1 97 Gyproc SoundBloc 1 x 12.5 3800 41 - Medium 22 A206A164 -

3 97 Gyproc WallBoard 1 x 12.5 3800 44 - Medium 19 A206A138 -

2 97 Gyproc SoundBloc 1 x 12.5 3800 48 - Medium 22 A206A196 -

3 97 Gyproc SoundBloc 1 x 12.5 3800 49 50 Medium 23 A206A228 A206A228S

1 102 Gyproc WallBoard 1 x 15 4000 38 39 Medium 22 A206A014 A206A014S

4 102 Gyproc SoundBloc 1 x 15 4000 50 51 Heavy 26 A206A252 A206A252S

60 minutes fire resistance

1 102 Gyproc FireLine 1 x 15 4000 39 40 Heavy 24 A206A078 A206A078S

1 102 Gyproc SoundBloc f 1 x 15 4000 42 - Heavy 27 A206A301 -

2 102 Gyproc FireLine 1 x 15 4000 43 44 Heavy 24 A206A110 A206A110S

3 102 Gyproc FireLine 1 x 15 4000 44 45 Heavy 24 A206A141 A206A141S

2 102 Gyproc SoundBloc f 1 x 15 4000 48 - Heavy 27 A206A302 -

4 102 Gyproc SoundBloc f 1 x 15 3000 50 51 Heavy 27 A206A304 A206A304S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P07 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
70mm Gypframe AcouStuds - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 3b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3 4

One layer of board each side of One layer of board each side of 70mm One layer of board each side of 70mm One layer of board each side of 70mm
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 600mm centres. 3 x 25mm
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table. in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²

C04
Any2 Skim3 Any2 Skim3
finish only finish only

30 minutes fire resistance

1 97 Gyproc SoundBloc 1 x 12.5 3800 41 - Medium 22 A206A164 -

3 97 Gyproc WallBoard 1 x 12.5 3800 44 - Medium 19 A206A138 -

2 97 Gyproc SoundBloc 1 x 12.5 3800 48 - Medium 22 A206A196 -

3 97 Gyproc SoundBloc 1 x 12.5 3800 49 50 Medium 23 A206A228 A206A228S

4 102 Gyproc SoundBloc 1 x 15 4000 50 51 Heavy 26 A206A252 A206A252S

60 minutes fire resistance

1 102 Gyproc FireLine 1 x 15 4000 39 40 Heavy 24 A206A078 A206A078S

1 102 Gyproc SoundBloc f 1 x 15 4000 42 - Heavy 27 A206A301 -

2 102 Gyproc FireLine 1 x 15 4000 43 44 Heavy 24 A206A110 A206A110S

3 102 Gyproc FireLine 1 x 15 4000 44 45 Heavy 24 A206A141 A206A141S

2 102 Gyproc SoundBloc f 1 x 15 4000 48 - Heavy 27 A206A302 -

4 102 Gyproc SoundBloc f 1 x 15 4000 50 51 Heavy 27 A206A304 A206A304S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P08


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
92mm Gypframe 'C' Studs - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 4a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

One layer of board each side of 92mm One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

4 5
Partitions

One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. 3 x 25mm Gypframe ‘C’ Studs at 600mm centres.
C04

Isover Acoustic Partition Roll (APR 1200) 100mm Isover Modular Roll in the cavity.
in the cavity. Linings as in table. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any finish2 Skim only3 Any finish2 Skim only3

30 minutes fire resistance

4 119 Gyproc SoundBloc 1 x 12.5 4000 50 51 Medium 23 A206232 A206232S

1 124 Gyproc SoundBloc 1 x 15 4000 44 45 Heavy 27 A206261 A206261S

2 124 Gyproc SoundBloc 1 x 15 4000 49 50 Heavy 27 A206262 A206262S

3 124 Gyproc SoundBloc 1 x 15 4000 50 51 Heavy 27 A206263 A206263S

5 124 Gyproc SoundBloc 1 x 15 4000 51 52 Heavy 27 A206264 A206264S

4 124 Gyproc SoundBloc 1 x 15 4000 52 53 Heavy 27 A206233 A206233S

60 minutes fire resistance

1 124 Gyproc FireLine 1 x 15 4000 40 41 Heavy 25 A206265 A206265S

1 124 Gyproc SoundBloc f 1 x 15 4000 44 45 Heavy 27 A206305 A206305S

2 124 Gyproc FireLine 1 x 15 4000 44 4


45
4
Heavy 25 A206266 A206266S

5 124 Gyproc FireLine 1 x 15 4000 46 48 Heavy 25 A206268 A206268S

2 124 Gyproc SoundBloc f 1 x 15 4000 49 50 Heavy 27 A206306 A206306S

3 124 Gyproc SoundBloc f 1 x 15 4000 50 51 Heavy 27 A206309 A206309S

5 124 Gyproc SoundBloc f 1 x 15 4000 51 52 Heavy 27 A206308 A206308S

4 124 Gyproc SoundBloc f 1 x 15 4000 52 53 Heavy 27 A206307 A206307S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing the insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve the system performance.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P09 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
92mm Gypframe 'C' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 4b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3

One layer of board each side of 92mm One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

4 5

Partitions
One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe ‘C’ Studs at 600mm centres. 3 x 25mm Gypframe ‘C’ Studs at 600mm centres.

C04
Isover Acoustic Partition Roll (APR 1200) 100mm Isover Modular Roll in the cavity.
in the cavity. Linings as in table. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any finish2 Skim only3 Any finish2 Skim only3

30 minutes fire resistance

4 119 Gyproc SoundBloc 1 x 12.5 4500 50 51 Medium 23 A206232 A206232S

1 124 Gyproc SoundBloc 1 x 15 4700 44 45 Heavy 27 A206261 A206261S

2 124 Gyproc SoundBloc 1 x 15 4700 49 50 Heavy 27 A206262 A206262S

3 124 Gyproc SoundBloc 1 x 15 4700 50 51 Heavy 27 A206263 A206263S

5 124 Gyproc SoundBloc 1 x 15 4700 51 52 Heavy 27 A206264 A206264S

4 124 Gyproc SoundBloc 1 x 15 4700 52 53 Heavy 27 A206233 A206233S

60 minutes fire resistance

1 124 Gyproc FireLine 1 x 15 4700 40 41 Heavy 25 A206265 A206265S

1 124 Gyproc SoundBloc f 1 x 15 4700 44 45 Heavy 27 A206305 A206305S

2 124 Gyproc FireLine 1 x 15 4700 444 454 Heavy 25 A206266 A206266S

5 124 Gyproc FireLine 1 x 15 4700 46 48 Heavy 25 A206268 A206268S

2 124 Gyproc SoundBloc f 1 x 15 4700 49 50 Heavy 27 A206306 A206306S

3 124 Gyproc SoundBloc f 1 x 15 4700 50 51 Heavy 27 A206309 A206309S

5 124 Gyproc SoundBloc f 1 x 15 4700 51 52 Heavy 27 A206308 A206308S

4 124 Gyproc SoundBloc f 1 x 15 4700 52 53 Heavy 27 A206307 A206307S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to deflection
criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P10


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
92mm Gypframe AcouStuds - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 5a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3 4

One layer of board each side of 92mm One layer of board each side of One layer of board each side of One layer of board each side of 92mm
Gypframe AcouStuds at 600mm centres. 92mm Gypframe AcouStuds at 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in the
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) cavity. Linings as in table.
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
C04

mm mm mm Any2 Skim3 kg/m² Any2 Skim3


finish only finish only

30 minutes fire resistance

1 124 Gyproc SoundBloc 1 x 15 4000 45 46 Heavy 27 A206A281 A206A281S

2 124 Gyproc SoundBloc 1 x 15 4000 50 51 Heavy 27 A206A282 A206A282S

3 124 Gyproc SoundBloc 1 x 15 4000 51 52 Heavy 27 A206A283 A206A283S

4 124 Gyproc SoundBloc 1 x 15 4000 52 54 Heavy 27 A206A284 A206A284S

60 minutes fire resistance

1 124 Gyproc FireLine 1 x 15 4000 41 42 Heavy 24 A206A285 A206A285S

2 124 Gyproc FireLine 1 x 15 4000 444 454 Heavy 24 A206A286 A206A286S

1 124 Gyproc SoundBloc f 1 x 15 4000 45 46 Heavy 27 A206A305 A206A305S

4 124 Gyproc FireLine 1 x 15 4000 46 48 Heavy 24 A206A288 A206A288S

2 124 Gyproc SoundBloc f 1 x 15 4000 50 51 Heavy 27 A206A306 A206A306S

3 124 Gyproc SoundBloc f 1 x 15 4000 51 52 Heavy 27 A206A309 A206A309S

4 124 Gyproc SoundBloc f 1 x 15 4000 52 54 Heavy 27 A206A308 A206A308S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P11 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
92mm Gypframe AcouStuds - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 5b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3 4

One layer of board each side of 92mm One layer of board each side of One layer of board each side of One layer of board each side of 92mm
Gypframe AcouStuds at 600mm centres. 92mm Gypframe AcouStuds at 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in the
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) cavity. Linings as in table.
in the cavity. Linings as in table. in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight

C04
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only

30 minutes fire resistance

1 124 Gyproc SoundBloc 1 x 15 4900 45 46 Heavy 27 A206A281 A206A281S

2 124 Gyproc SoundBloc 1 x 15 4900 50 51 Heavy 27 A206A282 A206A282S

3 124 Gyproc SoundBloc 1 x 15 4900 51 52 Heavy 27 A206A283 A206A283S

4 124 Gyproc SoundBloc 1 x 15 4900 52 54 Heavy 27 A206A284 A206A284S

60 minutes fire resistance

1 124 Gyproc FireLine 1 x 15 4900 41 42 Heavy 24 A206A285 A206A285S

2 124 Gyproc FireLine 1 x 15 4900 445 455 Heavy 24 A206A286 A206A286S

1 124 Gyproc SoundBloc f 1 x 15 4900 45 46 Heavy 27 A206A305 A206A305S

4 124 Gyproc FireLine 1 x 15 4900 46 48 Heavy 24 A206A288 A206A288S

2 124 Gyproc SoundBloc f 1 x 15 4900 50 51 Heavy 27 A206A306 A206A306S

3 124 Gyproc SoundBloc f 1 x 15 4900 51 52 Heavy 27 A206A309 A206A309S

4 124 Gyproc SoundBloc f 1 x 15 4900 52 54 Heavy 27 A206A308 A206A308S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P12


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
48mm Gypframe 'C' Studs - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 6a — Solutions to satisfy the requirements of BS EN 1364-1

1 2

Two layers of board each side of 48mm Two layers of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating4 weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04

finish only finish only

30 minutes fire resistance

1 100 Gyproc WallBoard 2 x 12.5 3400 42 - Severe 35 A206003 -

Outer layer Glasroc H tilebacker 1 x 12.5


1 100 3400 42 - Severe 39 H206003 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 100 Gyproc WallBoard 2 x 12.5 3000 49 - Severe 35 A206035 -
Outer layer Glasroc H tilebacker 1 x 12.5
2 100 3000 49 - Severe 39 H206035 -
+ inner layer Gyproc WallBoard + 1 x 12.5

60 minutes fire resistance

1 100 Gyproc SoundBloc 2 x 12.5 3000 46 - Severe 43 A206154 -

2 100 Gyproc SoundBloc 2 x 12.5 3000 51 - Severe 43 A206186 -

1 110 Gyproc WallBoard 2 x 15 3700 45 - Severe 42 A206004 -

90 minutes fire resistance

1 110 Gyproc SoundBloc 2 x 15 3000 49 - Severe 51 A206155 -

2 110 Gyproc SoundBloc 2 x 15 3000 53 54 Severe 51 A206187 A206187S

120 minutes fire resistance

1 100 Gyproc FireLine 2 x 12.5 3400 42 - Severe 40 A206067 -

2 100 Gyproc FireLine 2 x 12.5 3400 49 - Severe 40 A206099 -

1 110 Gyproc FireLine 2 x 15 3700 45 - Severe 49 A206156 -

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Refer to relevant test reports for observations noted during test.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S02. P13 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
48mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 6b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2

Two layers of board each side of 48mm Two layers of board each side of 48mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating4 weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3

C04
finish only finish only

60 minutes fire resistance

1 100 Gyproc WallBoard 2 x 12.5 3400 42 - Severe 35 A206003 -


Outer layer Glasroc H tilebacker 1 x 12.5
1 100 3400 42 - Severe 39 H206003 -
+ inner layer Gyproc WallBoard + 1 x 12.5
1 100 Gyproc SoundBloc 2 x 12.5 3400 46 - Severe 43 A206154 -

2 100 Gyproc WallBoard 2 x 12.5 3400 49 - Severe 35 A206035 -


Outer layer Glasroc H tilebacker 1 x 12.5
2 100 3400 49 - Severe 39 H206035 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 100 Gyproc SoundBloc 2 x 12.5 3400 51 - Severe 43 A206186 -

90 minutes fire resistance

1 110 Gyproc WallBoard 2 x 15 3700 45 - Severe 42 A206004 -

1 110 Gyproc SoundBloc 2 x 15 3700 49 - Severe 51 A206155 -

2 110 Gyproc WallBoard 2 x 15 3700 49 - Severe 42 A206036 -

2 110 Gyproc SoundBloc 2 x 15 3700 53 54 Severe 51 A206187 A206187S

120 minutes fire resistance

1 100 Gyproc FireLine 2 x 12.5 3400 42 - Severe 40 A206067 -

2 100 Gyproc FireLine 2 x 12.5 3400 49 - Severe 40 A206099 -

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Refer to relevant test reports for observations noted during test.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P14


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
70mm Gypframe 'C' Studs - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 7a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

Two layers of board each side of 70mm Two layers of board each side of 70mm Two layers of board each side of 70mm
Gypframe ‘C’ Studs at 600mm centres. Gypframe ‘C’ Studs at 600mm centres. 25mm Gypframe ‘C’ Studs at 600mm centres. 50mm
Linings as in table. Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
C04

finish only finish only

30 minutes fire resistance

1 122 Gyproc WallBoard 2 x 12.5 4600 45 - Severe 35 A206015 -


Outer layer Glasroc H tilebacker 1 x 12.5
1 122 4600 45 - Severe 39 H206015 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 122 Gyproc WallBoard 2 x 12.5 4600 49 - Severe 35 A206047 -

60 minutes fire resistance

1 122 Gyproc SoundBloc 2 x 12.5 4600 49 - Severe 43 A206166 -

3 122 Gyproc WallBoard 2 x 12.5 4000 50 - Severe 35 A206142 -


Outer layer Glasroc H tilebacker 1 x 12.5
3 122 4000 50 - Severe 39 H206142 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 122 Gyproc SoundBloc 2 x 12.5 4000 52 - Severe 43 A206198 -

3 122 Gyproc SoundBloc 2 x 12.5 4000 53 - Severe 44 A206230 -

1 132 Gyproc WallBoard 2 x 15 4900 46 47 Severe 42 A206016 A206016S

2 132 Gyproc WallBoard 2 x 15 4000 50 - Severe 42 A206048 -

90 minutes fire resistance

1 132 Gyproc SoundBloc 2 x 15 4000 51 52 Severe 51 A206167 A206167S

2 132 Gyproc SoundBloc 2 x 15 4000 54 55 Severe 51 A206199 A206199S

3 132 Gyproc SoundBloc 2 x 15 4000 56 57 Severe 52 A206231 A206231S

120 minutes fire resistance

1 122 Gyproc FireLine 2 x 12.5 4200 46 - Severe 40 A206079 -

2 122 Gyproc FireLine 2 x 12.5 4000 49 - Severe 40 A206111 -

3 122 Gyproc FireLine 2 x 12.5 4000 50 - Severe 40 A206144 -

1 132 Gyproc FireLine 2 x 15 4900 46 47 Severe 47 A206251 A206251S

2 132 Gyproc FireLine 2 x 15 4300 50 - Severe 49 A206253 -

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S02. P15 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
70mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 7b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3

Two layers of board each side of 70mm Two layers of board each side of Two layers of board each side of
Gypframe ‘C’ Studs at 600mm centres. 70mm Gypframe ‘C’ Studs at 600mm centres. 70mm Gypframe ‘C’ Studs at 600mm centres.
Linings as in table. 25mm Isover Acoustic Partition Roll (APR 1200) 50mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3

C04
finish only finish only

60 minutes fire resistance

1 122 Gyproc WallBoard 2 x 12.5 4600 45 - Severe 35 A206015 -


Outer layer Glasroc H tilebacker 1 x 12.5
1 122 4600 45 - Severe 39 H206015 -
+ inner layer Gyproc WallBoard + 1 x 12.5
1 122 Gyproc SoundBloc 2 x 12.5 4600 49 - Severe 43 A206166 -

2 122 Gyproc WallBoard 2 x 12.5 4600 49 - Severe 35 A206047 -


Outer layer Glasroc H tilebacker 1 x 12.5
2 122 4600 49 - Severe 39 H206047 -
+ inner layer Gyproc WallBoard + 1 x 12.5
3 122 Gyproc WallBoard 2 x 12.5 4600 50 - Severe 36 A206142 -
Outer layer Glasroc H tilebacker 1 x 12.5
3 122 4600 50 - Severe 39 H206142 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 122 Gyproc SoundBloc 2 x 12.5 4600 52 - Severe 43 A206198 -

3 122 Gyproc SoundBloc 2 x 12.5 4600 53 - Severe 44 A206230 -

90 minutes fire resistance

1 132 Gyproc WallBoard 2 x 15 4900 46 47 Severe 42 A206016 A206016S

2 132 Gyproc WallBoard 2 x 15 4900 50 - Severe 42 A206048 -

1 132 Gyproc SoundBloc 2 x 15 4900 51 52 Severe 51 A206167 A206167S

2 132 Gyproc SoundBloc 2 x 15 4900 54 55 Severe 51 A206199 A206199S

3 132 Gyproc SoundBloc 2 x 15 4900 56 57 Severe 52 A206231 A206231S

120 minutes fire resistance

1 112 Glasroc F multiboard 2 x 10 4200 42 -- Severe 40 G106013 -

1 122 Gyproc FireLine 2 x 12.5 4600 46 - Severe 40 A206079 -

2 122 Gyproc FireLine 2 x 12.5 4600 49 - Severe 40 A206111 -

3 122 Gyproc FireLine 2 x 12.5 4600 50 - Severe 41 A206144 -

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P16


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
70mm Gypframe AcouStuds - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 8a – Solutions to satisfy the requirements of BS EN 1364-1

1 2

Two layers of board each side of Two layers of board each side of 70mm
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at 600mm centres.
600mm centres. Linings as in table. 25mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
C04

finish only finish only

30 minutes fire resistance

1 122 Gyproc WallBoard 2 x 12.5 4700 47 - Severe 35 A206A015 -

60 minutes fire resistance

1 122 Gyproc SoundBloc 2 x 12.5 4700 53 - Severe 43 A206A166 -

2 122 Gyproc SoundBloc 2 x 12.5 4000 58 59 Severe 43 A206A198 A206A198S

90 minutes fire resistance

1 122 Gyproc FireLine 2 x 12.5 4700 49 50 Severe 40 A206A079 A206A079S

2 122 Gyproc FireLine 2 x 12.5 4700 54 55 Severe 40 A206A111 A206A111S

1 132 Gyproc SoundBloc 2 x 15 4000 54 55 Severe 51 A206A167 A206A167S

120 minutes fire resistance

1 122 Gyproc FireLine 2 x 12.5 4200 49 50 Severe 40 A206A079 A206A079S

2 122 Gyproc FireLine 2 x 12.5 4000 54 55 Severe 40 A206A111 A206A111S

1 132 Gyproc FireLine 2 x 15 5000 49 50 Severe 49 A206A251 A206A251S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S02. P17 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
70mm Gypframe AcouStuds - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 8b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2

Two layers of board each side of Two layers of board each side of 70mm
70mm Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at 600mm centres.
600mm centres. Linings as in table. 25mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.

Partitions
Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3

C04
finish only finish only

60 minutes fire resistance

1 122 Gyproc WallBoard 2 x 12.5 4700 47 - Severe 35 A206A015 -

1 122 Gyproc SoundBloc 2 x 12.5 4700 53 - Severe 43 A206A166 -

2 122 Gyproc SoundBloc 2 x 12.5 4700 58 59 Severe 43 A206A198 A206A198S

90 minutes fire resistance

1 132 Gyproc SoundBloc 2 x 15 5000 54 55 Severe 51 A206A167 A206A167S

120 minutes fire resistance

1 122 Gyproc FireLine 2 x 12.5 4700 49 50 Severe 40 A206A079 A206A079S

2 122 Gyproc FireLine 2 x 12.5 4700 54 55 Severe 40 A206A111 A206A111S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P18


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
92mm Gypframe 'C' Studs - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 9a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3 4

Two layers of board each side of Two layers of board each side of Two layers of board each side of Two layers of board each side of
92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 600mm
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 3 x 25mm centres. 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.
Partitions

in the cavity. Linings as in table. in the cavity. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04

thickness type thickness height1 Rw (Rw + Ctr) dB rating weight


mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only

60 minutes fire resistance

3 144 Gyproc SoundBloc 2 x 12.5 4000 56 (51) - Severe 44 A206234 -

90 minutes fire resistance

1 154 Gyproc SoundBloc 2 x 15 5000 52 53 Severe 52 A206269 A206269S

4 154 Gyproc FireLine 2 x 15 4000 53 55 Severe 49 A206276 A206276S

2 154 Gyproc SoundBloc 2 x 15 5000 56 4


57 4
Severe 52 A206270 A206270S

120 minutes fire resistance

1 154 Gyproc FireLine 2 x 15 5900 50 51 Severe 48 A206273 A206273S

2 154 Gyproc FireLine 2 x 15 5000 52 4


53 4
Severe 48 A206274 A206274S

4 154 Gyproc FireLine 2 x 15 3000 53 55 Severe 49 A206276 A206276S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing the insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve the system performance.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S02. P19 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
92mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 9b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3 4

Two layers of board each side of Two layers of board each side of Two layers of board each side of Two layers of board each side of 92mm
92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at 92mm Gypframe ‘C’ Studs at Gypframe ‘C’ Studs at 600mm centres.
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 3 x 25mm 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.

Partitions
in the cavity. Linings as in table. in the cavity. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference

C04
thickness type thickness height1 Rw (Rw + Ctr) dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
finish only finish only

60 minutes fire resistance

3 144 Gyproc SoundBloc 2 x 12.5 5700 56 (51) - Severe 44 A206234 -

90 minutes fire resistance

1 154 Gyproc SoundBloc 2 x 15 5900 52 53 Severe 52 A206269 A206269S

2 154 Gyproc SoundBloc 2 x 15 5900 564 574 Severe 52 A206270 A206270S

120 minutes fire resistance

1 154 Gyproc FireLine 2 x 155 5900 50 51 Severe 48 A206273 A206273S

2 154 Gyproc FireLine 2 x 15 5


5900 52 4
53 4
Severe 48 A206274 A206274S

4 154 Gyproc FireLine 2 x 155 5900 53 55 Severe 49 A206276 A206276S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.
5
2 x 12.5mm lining thickness is acceptable for 120 minutes BS up to a maximum height of 5700mm but acoustic test data is not available.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P20


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
92mm Gypframe AcouStuds - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 10a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3 4

Two layers of board each side of Two layers of board each side Two layers of board each side Two layers of board each side of 92mm
92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.
Partitions

in the cavity. Linings as in table. in the cavity. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04

thickness type thickness height1 Rw (Rw + Ctr ) dB rating weight


mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only

60 minutes fire resistance

1 144 Gyproc SoundBloc 2 x 12.5 5000 54 55 Severe 44 A206A289 A206A289S

2 144 Gyproc SoundBloc 2 x 12.5 5000 57 (51) 58 (51) Severe 45 A206A290 A206A290S

3 144 Gyproc SoundBloc 2 x 12.5 5000 58 (53) 59 (53) Severe 45 A206A291 A206A291S

4 144 Gyproc SoundBloc 2 x 12.5 5000 59 (54) 60 (54) Severe 45 A206A292 A206A292S

120 minutes fire resistance

1 144 Gyproc FireLine 2 x 12.5 3000 51 52 Severe 41 A206A293 A206A293S

3 144 Gyproc FireLine 2 x 12.5 4000 55 56 Severe 42 A206A295 A206A295S

4 144 Gyproc FireLine 2 x 12.5 3000 56 58 Severe 42 A206A296 A206A296S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S02. P21 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
92mm Gypframe AcouStuds - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 10b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3 4

Two layers of board each side Two layers of board each side Two layers of board each side Two layers of board each side of 92mm
of 92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at of 92mm Gypframe AcouStuds at Gypframe AcouStuds at 600mm centres.
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm 100mm Isover Modular Roll in
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200) the cavity. Linings as in table.

Partitions
in the cavity. Linings as in table. in the cavity. Linings as in table.

Refer to GypWall robust and GypWall extreme sections for single layer Severe Duty solutions
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference

C04
thickness type thickness height1 Rw (Rw + Ctr ) dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only

60 minutes fire resistance

1 144 Gyproc SoundBloc 2 x 12.5 5800 54 55 Severe 44 A206A289 A206A289S

2 144 Gyproc SoundBloc 2 x 12.5 5800 57 (51) 58 (51) Severe 45 A206A290 A206A290S

3 144 Gyproc SoundBloc 2 x 12.5 5800 58 (53) 59 (53) Severe 45 A206A291 A206A291S

4 144 Gyproc SoundBloc 2 x 12.5 5800 59 (54) 60 (54) Severe 45 A206A292 A206A292S

120 minutes fire resistance

1 144 Gyproc FireLine 2 x 12.5 5800 51 52 Severe 41 A206A293 A206A293S

3 144 Gyproc FireLine 2 x 12.5 5800 55 56 Severe 42 A206A295 A206A295S

4 144 Gyproc FireLine 2 x 12.5 5800 56 58 Severe 42 A206A296 A206A296S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P22


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
146mm Gypframe 'C' Studs - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 11a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

Two layers of board each side of 146mm Two layers of board each side of Two layers of board each side of
Gypframe ‘C’ Studs at 146mm Gypframe ‘C’ Studs at 146mm Gypframe ‘C’ Studs at
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm
Partitions

Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.
C04

Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw (Rw + Ctr ) dB rating weight
mm mm mm Any2 Skim3 kg/m² Any2 Skim3
finish only finish only

30 minutes fire resistance

1 198 Gyproc WallBoard 2 x 12.5 7600 50 51 Severe 35 A206027 A206027S


Outer layer Glasroc H tilebacker 1 x 12.5 +
1 198 7600 50 - Severe 39 H206027 -
+ inner layer Gyproc WallBoard 1 x 12.5

60 minutes fire resistance

3 198 Gyproc WallBoard 2 x 12.5 4000 51 52 Severe 36 A206149 A206149S


Outer layer Glasroc H tilebacker 1 x 12.5 +
3 198 4000 51 - Severe 40 H206149 -
+ inner layer Gyproc WallBoard 1 x 12.5
1 198 Gyproc SoundBloc 2 x 12.5 5000 53 54 Severe 43 A206178 A206178S

2 198 Gyproc SoundBloc 2 x 12.5 4000 55 (49) 56 (49) Severe 43 A206210 A206210S

1 208 Gyproc WallBoard 2 x 15 5000 50 - Severe 42 A206028 -

2 208 Gyproc WallBoard 2 x 15 4000 51 - Severe 42 A206060 -

90 minutes fire resistance

1 208 Gyproc SoundBloc 2 x 15 3000 56 (50) 57 (50) Severe 51 A206179 A206179S

3 208 Gyproc SoundBloc 2 x 15 4000 59 (53) 60 (53) Severe 52 A206243 A206243S

120 minutes fire resistance

1 198 Gyproc FireLine 2 x 12.5 4200 50 51 Severe 40 A206091 A206091S

2 198 Gyproc FireLine 2 x 12.5 4000 51 52 Severe 40 A206123 A206123S

1 208 Gyproc FireLine 2 x 15 7900 50 - Severe 46 A206180 -

2 208 Gyproc FireLine 2 x 15 7800 51 - Severe 46 A206181 -

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S02. P23 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
146mm Gypframe 'C' Studs - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 11b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3

Two layers of board each side of 146mm Two layers of board each side of 146mm Two layers of board each side of 146mm
Gypframe ‘C’ Studs at Gypframe ‘C’ Studs at Gypframe ‘C’ Studs at
600mm centres. Linings as in table. 600mm centres. 25mm 600mm centres. 50mm

Partitions
Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table.

C04
Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
thickness type thickness height1 Rw (Rw + Ctr ) dB rating weight
mm mm mm kg/m²
Any2 Skim3 Any2 Skim3
finish only finish only

60 minutes fire resistance

1 198 Gyproc WallBoard 2 x 12.5 7600 50 51 Severe 35 A206027 A206027S


Outer layer Glasroc H tilebacker 1 x 12.5
1 198 7600 50 - Severe 39 H206027 -
+ inner layer Gyproc WallBoard + 1 x 12.5
2 198 Gyproc WallBoard 2 x 12.5 7600 51 52 Severe 35 A206059 A206059S
Outer layer Glasroc H tilebacker 1 x 12.5
2 198 7600 51 - Severe 39 H206059 -
+ inner layer Gyproc WallBoard + 1 x 12.5
1 198 Gyproc SoundBloc 2 x 12.5 7600 53 54 Severe 43 A206178 A206178S

2 198 Gyproc SoundBloc 2 x 12.5 7600 55 (49) 56 (49) Severe 43 A206210 A206210S

3 198 Gyproc SoundBloc 2 x 12.5 7600 56 (50) 57 (50) Severe 43 A206244 A206244S

90 minutes fire resistance

1 208 Gyproc WallBoard 2 x 15 7900 50 - Severe 42 A206028 -

2 208 Gyproc WallBoard 2 x 15 7900 51 - Severe 42 A206060 -

1 208 Gyproc SoundBloc 2 x 15 7900 56 (50) 57 (50) Severe 51 A206179 A206179S

2 208 Gyproc SoundBloc 2 x 15 7900 58 (52) - Severe 51 A206211 -

3 208 Gyproc SoundBloc 2 x 15 7900 59 (53) 60 (53) Severe 52 A206243 A206243S

120 minutes fire resistance

1 188 Glasroc F multiboard 2 x 10 7100 48 - Severe 40 G106014 -

1 198 Gyproc FireLine 2 x 12.5 7600 50 51 Severe 40 A206091 A206091S

2 198 Gyproc FireLine 2 x 12.5 7600 51 52 Severe 40 A206123 A206123S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P24


GypWall classic performance (continued)
GypWall classic

For details of when


to specify fire
146mm Gypframe AcouStuds - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 12a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

Two layers of board each sideof 146mm Two layers of board each side of 146mm Two layers of board each side of 146mm
Gypframe 146 AS 50 AcouStuds at Gypframe 146 AS 50 AcouStuds at 600mm centres. Gypframe 146 AS 50 AcouStuds at 600mm centres.
Partitions

600mm centres. Linings as in table. 50mm Isover Acoustic Partition Roll (APR 1200) 150mm Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. (100mm and 50mm) in the cavity.
Linings as in table.

Detail Partition Board Lining Max Sound insulation Duty Approx. System reference
C04

thickness type thickness partition Rw (Rw + Ctr ) dB rating weight


mm mm height1 Any2 Skim3 kg/m² Any2 Skim3
mm finish only finish only

60 minutes fire resistance

1 208 Gyproc WallBoard 2 x 15 5000 52 (47) 54 (47) Severe 42 A206A028 A206A028S

1 208 Gyproc SoundBloc 2 x 15 5000 59 (54) 60 (54) Severe 51 A206A179 A206A179S

3 208 Gyproc SoundBloc 2 x 15 5000 61 (57) 63 (57) Severe 53 A206A255 A206A255S

90 minutes fire resistance

1 198 Gyproc FireLine 2 x 12.5 7800 52 (48) 53 (48) Severe 40 A206A091 A206A091S

1 208 Gyproc SoundBloc 2 x 15 4000 59 (54) 60 (54) Severe 51 A206A179 A206A179S

2 208 Gyproc SoundBloc 2 x 15 4000 61 (56) 62 (56) Severe 52 A206A243 A206A243S

3 208 Gyproc SoundBloc 2 x 15 4000 61 (57) 63 (57) Severe 53 A206A255 A206A255S

120 minutes fire resistance

1 198 Gyproc FireLine 2 x 12.5 4200 52 (48) 53 (48) Severe 40 A206A091 A206A091S

1 208 Gyproc FireLine 2 x 15 8100 52 (47) 54 (47) Severe 50 A206A180 A206A180S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

For heights over 8000mm, Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at head and base.

C04. S02. P25 british-gypsum.com


GypWall classic performance (continued)

GypWall classic
For details of when
to specify fire
146mm Gypframe AcouStuds - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 12b — Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3

Two layers of board each side of 146mm


Two layers of board each side Two layers of board each side of 146mm Gypframe
Gypframe 146 AS 50 AcouStuds at 600mm centres.

Partitions
of 146mm Gypframe 146 AS 50 AcouStuds 146 AS 50 AcouStuds at 600mm centres. 50mm
150mm Isover Acoustic Partition Roll (APR 1200)
at 600mm centres. Linings as in table. Isover Acoustic Partition Roll (APR 1200)
(100mm and 50mm) in the cavity.
in the cavity. Linings as in table.
Linings as in table.

Detail Partition Board Lining Max Sound insulation Duty Approx. System reference

C04
thickness type thickness partition Rw (Rw + Ctr ) dB rating weight
mm mm height1 Any2 Skim3 kg/m² Any2 Skim3
mm finish only finish only

90 minutes fire resistance

1 208 Gyproc WallBoard 2 x 15 8100 52 (47) 54 (47) Severe 42 A206A028 A206A028S

1 208 Gyproc SoundBloc 2 x 15 8100 59 (54) 60 (54) Severe 51 A206A179 A206A179S

2 208 Gyproc SoundBloc 2 x 15 8100 61 (56) 62 (56) Severe 52 A206A243 A206A243S

3 208 Gyproc SoundBloc 2 x 15 8100 61 (57) 63 (57) Severe 53 A206A255 A206A255S

120 minutes fire resistance

1 198 Gyproc FireLine 2 x 12.5 7800 52 (48) 53 (48) Severe 40 A206A091 A206A091S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of Gypframe ‘I’ Studs, or reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

For heights over 8000mm, Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at head and base.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P26


GypWall classic design
GypWall classic

Building design Framing surround for openings

Whilst our GypWall partition systems are non-loadbearing, they Where services such as horizontal ducts, fire dampers and access
are able to provide resistance to levels of horizontal uniformly panels are required to penetrate the wall, their position should be
distributed loads in accordance with BS 6399. pre-determined in order that a framed opening can be provided.
The openings should be constructed using established metal stud
Refer to C02. S01. P26 – Robustness.
procedures.

Planning – key factors Refer to Partitions introduction C04. S01. P16 - construction
details 28-31.
GypWall classic comprises Gypframe 'C' Studs installed at 600mm
centres within Gypframe Floor & Ceiling Channels. The position
Cavity barriers
of services and heavy fixtures should be pre-determined and their
installation planned into the frame erection stage. Minimum 12.5mm Gyproc plasterboard, screw-fixed into the web
Partitions

of perimeter channels or vertical studs, will provide a satisfactory


Fixing floor and ceiling channels closure to flame or smoke.

Gypframe Floor & Ceiling Channels must be securely fixed with a Refer to C06. S07. P02 – Cavity barriers.
row of fixings at 600mm maximum centres. For 94mm and 148mm
channels, two rows of staggered fixings are required, each row at
C04

Control joints
600mm centres and each fixing 25mm in from the flange. If the
Control joints may be required in the partition to relieve stresses
floor is uneven, a 38mm thick timber sole plate equal to the width
induced by expansion and contraction of the structure (refer to
of the channel should be used.
Partitions introduction C04. S01. P10 – construction detail 12). They
should coincide with movement joints within the surrounding
If the concrete or screeded floor is new, consideration should be
structure.
given to the installation of a damp-proof membrane between the
floor surface and the channel or sole plate.
Deflection heads

Splicing Partition head deflection designs may be necessary to


accommodate deflections in the supporting floor. Deflection heads
To extend studs, overlap by 600mm (minimum). Fix together using
may also be required to the underside of roof structures subjected
British Gypsum Wafer Head Drywall Screws or steel pop rivets (two
to positive and negative pressures.
to each flange), or by using the Gyproc Stud Interlocking Tool twice
to each flange. Refer to Partitions introduction C04. S01. P11 – construction
details 15-22.
Refer to Partitions introduction C04. S01. P07 – construction
detail 1.
To minimise the loss of acoustic performance:

Partition to structural steelwork junctions Refer to C02. S01. P10 – Building acoustics.

When designing the layout of rooms requiring separation by sound


Services
insulating walls abutting structural steelwork, consideration should
be given to the potential loss of sound insulation performance Penetrations
through the steelwork. Penetrations of fire-resistant or sound-insulating constructions
for services need careful consideration to ensure that the
Refer to C02. S01. P10 – Building acoustics.
performance of the element is not downgraded. Consideration also
needs to be given to the services themselves so they do not act as
Door openings
the mechanism of fire spread or sound transmission.
The designer should consider thickness tolerances of the partition
Refer to C02. S01. P32 – Service installations.
types in relation to the proposed door frame detail. Standard door
frame detailing to suit BS 5234 Light and Medium Duty applications
is shown in Partitions introduction C04. S01. P13 – construction
detail 25. Detailing to satisfy BS 5234 requirements for Heavy and Handy hint
Severe Duty Rating is shown in Partitions introduction C04. S01. P14
– construction details 26 and 27. The door manufacturer should Where access is limited to one side of the
also be consulted in relation to door details. head, e.g. M+E cages already installed in
corridors
Specialist advice should be sought from door manufacturers and
Refer to C05. S02. P02 - ShaftWall.
Acoustic Consultants to ensure the required acoustic performance
is achieved. This becomes more important as acoustic requirements
increase.

C04. S02. P27 british-gypsum.com


GypWall classic
GypWall classic design (continued)

Electrical
The installation of electrical services should be carried out in
accordance with BS 7671. The cut-outs in the studs can be used Handy hint
for routing electrical and other small services (refer to Partitions
introduction C04. S01. P07 – construction detail 2). Switch boxes For alternative stud types and / or reduced
and socket outlets can be supported from Gypframe 99 FC 50 Fixing centres, to increase maximum partition
Channel fixed horizontally between studs, or a high performance height, further options are available.
socket box detail used where higher acoustic performance is Refer to C04. S01. P05, table 2.
required.

Where Gypframe AcouStuds are used, services are routed through


50mm x 28mm ‘H’ shaped push-outs, at the same centres as shown

Partitions
in Partitions introduction C04. S01. P07 – construction detail 2a
for conventional cut-outs. Cables should be protected by conduit,
SpecSure®
or other suitable precautions taken to prevent abrasion when they
All our systems are covered by SpecSure® when
pass through the metal frame. Service cut-outs should be aligned to
using genuine British Gypsum and Saint-Gobain
allow easy installation of service. If studs require cutting, cut from
Isover products.

C04
the same end of each stud to ensure cut-out alignment.

Independent support

When designing for the installation of services such as fire


dampers and associated ductwork through a GypWall partition,
consideration should be given to the size and weight of the
damper - this will determine whether it can be supported directly
from the partition or needs to be independently supported from the
structure.

Refer to Partitions introduction C04. S01. P17 – construction


details 29-31.

Fixtures

Lightweight fixtures can be made directly to the partition linings.


Medium weight fixtures can be made to Gypframe 99 FC 50
Fixing Channel. Heavyweight fixtures (to BS 5234) such as wash
basins and wall cupboards, can be fixed using plywood secured by
Gypframe Service Support Plates.

Refer to C02. S01. P33 – Service installations.

Access for maintenance

Gyproc Profilex Access Panels are available to provide access for


maintenance. Access panels must be fully compatible with drywall
construction and match the fire rating of the partition.

Refer to profilex.co.uk for further information.

Board finishing

Refer to C08. S01. P03 – Finishes.

Tiling

Tiles up to 32kg/m2 can be applied to the surface of lightweight


partition systems.

Refer to C08. S04. P02 – Tiling.

Construction details

For standard GypWall construction details

Refer to Partitions introduction C04. S01. P07 – construction


details.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P28


GypWall classic system components
GypWall classic

Gypframe metal components ( Refer to C10. S02. P02 for details)

Gypframe ‘C’ Studs (48 S 50, 70 S 50, 92 S 50, Gypframe Extra Deep Flange Floor & Ceiling
146 S 50) Channels (50 EDC 70, 72 EDC 80, 94 EDC 70,
Vertical stud providing acoustic and structural 148 EDC 80)
performances designed to receive fixing of board Floor and ceiling channels with extra deep flanges
to both sides. for retaining the Gypframe studs at floor and
ceiling junctions for partitions over 8000mm high.
Also used around openings and in deflection heads
(maximum 50mm deflection).
Partitions

Gypframe ‘I’ Studs (70 I 50, 92 I 90, 146 I 80, Gypframe 99 FC 50 Fixing Channel
146 TI 90) A versatile metal fixing channel used to support
Enhanced strength stud that allows for increased medium weight fixtures on walls.
partition height, designed to receive fixing of board.
C04

Gypframe AcouStud (70 AS 50, 92 AS 50, 146 AS 50) Gypframe GFS1 Fixing Strap
Vertical stud providing enhanced acoustic and Used to support horizontal board joints and within
structural performances designed to receive deflection heads.
fixing of board to both sides.

Gypframe Folded Edge Standard Floor & Ceiling Gypframe GFT1 Fixing T
Channels (50 FEC 50, 72 FEC 50, 94 FEC 50, Used to support horizontal board joints.
148 FEC 50)
Standard floor and ceiling channels for retaining
the Gypframe studs at floor and ceiling junctions Gypframe GA6 Splayed Angle
and around openings to heights not exceeding Steel angle providing framing stability and
4200mm. board support.

Gypframe Deep Flange Floor & Ceiling Channels Gypframe Service Support Plate
(50 DC 60, 72 DC 60, 94 DC 60, 148 DC 60) For installation of 18mm plywood within
Floor and ceiling channels with deep flanges for a partition cavity to support medium to
retaining the Gypframe studs at floor and ceiling heavyweight fixtures.
junctions for partitions 4200mm to 8000mm high.
Also used around openings and in deflection heads
(maximum 30mm deflection).

Board products ( Refer to C10. S03. P02 for details)

Gyproc WallBoard Gyproc SoundBloc1


Standard gypsum plasterboard. Gypsum plasterboard with a high density core for
enhanced sound insulation performance.

Gyproc Moisture Resistant Gyproc SoundBloc f


Gypsum plasterboard with moisture resistant Gypsum plasterboard with fire resistant additives
additives in the core and special green lining paper and a high density core for enhanced sound
for easy recognition. insulation performance.

Gyproc FireLine1 Gyproc Plank


Gypsum plasterboard with fire resistant additives. Standard gypsum plasterboard located as an
inner layer.

1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

C04. S02. P29 british-gypsum.com


GypWall classic system components (continued)

GypWall classic
Board products ( Refer to C10. S03. P02 for details)

Glasroc H tilebacker3 Glasroc F firecase


Non-combustible glass-reinforced gypsum board Non-combustible glass-reinforced gypsum board.
with a water resistant pre-primed acrylic coating Used to form deflection head.
to receive tiling.

Glasroc F multiboard Gyproc CoreBoard


Non-combustible glass-reinforced gypsum board. Gypsum plasterboard with fire and moisture
Providing optimum acoustic and fire performance. resistant additives. Used to form deflection head.

Partitions
3
Glasroc H tilebacker is suitable for use in high moisture environments.

Fixing products ( Refer to C10. S04. P02 for details)

British Gypsum Drywall Screws British Gypsum Jack-Point Screws

C04
Corrosion resistant self-tapping steel screws For fixing boards to Gypframe metal framing
for fixing board to metal framing less than 0.8mm thick or greater (‘I’ studs 0.6mm thick
0.8mm thick ('I' studs less than 0.6mm thick). and greater).

British Gypsum Collated Drywall Screws British Gypsum Wafer Head Jack-Point Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws
for fixing board to metal framing less than for fixing metal to metal framing 0.8mm thick or
0.8mm thick ('I' studs less than 0.6mm thick). greater ('I' studs 0.6mm thick or greater).

British Gypsum Wafer Head Drywall Screws


Corrosion resistant self-tapping steel screws
for fixing metal to metal framing less than
0.8mm thick ('I' studs less than 0.6mm thick).

Plasterboard accessories ( Refer to C10. S05. P02 for details)

Gyproc Jointing Material Gyproc edge and angle beads


Jointing compounds, ready mixes and adhesives Protecting and enhancing board edges and corners
for reinforcement and finishing of board joints.
Primers and sealers for treatment of boards for
pre-decoration.

Gyproc FireStrip Gyproc Sealant


A soft extruded linear intumescent gap sealer Used to seal air paths for optimum sound
to maintain fire resistance located directly to insulation.
the underside of the soffit when forming a
deflection head.

Gyproc Control Joint Gyproc Joint Tape


To accommodate structural movement of up A paper tape designed for reinforcement of flat
to 7mm. joints or internal angles.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P30


GypWall classic system components (continued)
GypWall classic

Finishing products ( Refer to C10. S06. P02 for details)

Thistle MultiFinish ThistlePro DuraFinish


To provide a plaster skim finish on most common To provide a plaster skim finish and provide up to
backgrounds including undercoat plasters and 60% tougher resistance to accidental damage.
plasterboard. Can provide enhanced acoustic
performance.

Thistle BoardFinish ThistlePro PureFinish


To provide a plaster skim finish to To provide a plaster skim finish with
Gyproc plasterboards. ACTIVair technology. Used to finish most
Partitions

common backgrounds including undercoat plasters


and plasterboard. For more information refer to
C02. S01. P49.
C04

Thistle SprayFinish ThistlePro Magnetic


To provide a plaster skim finish by spray or hand To provide a plaster skim finish that provides an
application, ideal for medium to large projects. attraction to magnets used to finish a wide range
of backgrounds, including undercoat plasters and
plasterboard.

Thistle ProTape FT50 Plaster accessories


Self-adhesive 48mm wide glass fibre mesh tape. Designed for reinforcement and finishing of board
joints before plaster skimming.

Thistle ProTape FT100


Self-adhesive 100mm wide glass fibre mesh tape.

Insulation products ( Refer to C10. S09. P02 for details)

Isover Acoustic Partition Roll (APR 1200) Isover Modular Roll


Glass mineral wool for enhanced acoustic Glass mineral wool for enhanced acoustic
performance. performance.

Stone mineral wool (by others)


For fire-stopping.

Access panels ( Refer to profilex.co.uk for details)

Profilex Access Panel


Panel for access to cavity.

C04. S02. P31 british-gypsum.com


GypWall classic system installation overview

GypWall classic
Scan the image with this frame
for more information and
videos related to this system
This is intended to be a basic description of how the system is installed. Or visit gyp.sm/b/l2
For installation guidance refer to the British Gypsum Site Book.

Partitions
Appropriate Gypframe channels are suitably Gypframe 'C' Studs are suitably fixed to Gypframe studs are then friction fitted into
fixed to the floor and soffit. abutments. the Gypframe Floor & Ceiling Channels at
required centres.

C04
Door openings are constructed to suit the The perimeter of the partition is then sealed M&E services can be located within the
partitions' duty rating. on both sides with Gyproc Sealant. partition cavity.

Isover insulation can also be added to Gyproc plasterboards or Glasroc specialist


the partition cavity for increased acoustic boards are fixed to the Gypframe framework
performance. with British Gypsum Drywall Screws.

Additional information
For full installation details, refer to the
British Gypsum Site Book, available to
download from british-gypsum.com

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S02. P32


GypWall robust

GypWall robust
Durable impact resistant partition system

All our systems are covered by SpecSure® when using


genuine British Gypsum and Saint-Gobain Isover products
Partitions
C04
GypWall robust
GypWall robust
GypWall robust is a highly impact-resistant
60 120
partition system for use where a more durable mins

solution is required. All GypWall robust systems


utilise Gyproc DuraLine board to give enhanced
levels of resistance to damage from everyday 42 58
occurrences, such as school bags being knocked RwdB

against corridor walls as pupils move from

Partitions
one lesson to the next. As a result, the system
provides a lightweight, non-loadbearing System can be skim
finished with

partition ideal for all types of commercial, ThistlePro PureFinish.

C04
Refer to C02. S01. P49

healthcare and educational buildings that


experience high levels of human traffic.
Refer to C01. S01. P07

Key benefits
— Achieves Severe Duty Rating to BS 5234 with
only a single layer of Gyproc DuraLine
plasterboard to each side of the partition
— Reduced maintenance cycles due to impact
resistant nature of Gyproc DuraLine plasterboard
— Fully compatible with other British Gypsum
systems, GypWall robust can be specified
in areas of the building that really need it, whilst
other GypWall partitions can be used in lower
duty performance zones for optimal project value
— Increased levels of acoustic performance are
available when GypWall robust is specified with
Gypframe 92 AS 50 AcouStud – a commonly
chosen solution for school classrooms and
hospital consulting rooms
— Enhanced abrasion resistance can be achieved
through the use of ThistlePro DuraFinish skim
plaster; an ideal finishing solution for
GypWall robust

You may also be interested in...


For areas of a building where extreme levels of duty rating
may be required, for example a school corridor or hospital
circulation space, GypWall extreme provides the answer.
Refer to C04. S04. P02 - GypWall extreme

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S03. P02


GypWall robust performance
GypWall robust

For details of when


to specify fire
70mm Gypframe 'C' Studs - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 1a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 70 S 50 ‘C’ Studs at 600mm Gypframe 70 S 50 ‘C’ Studs at 600mm Gypframe 70 S 50 ‘C’ Studs at 600mm
centres. Linings as in table. centres. 25mm Isover Acoustic Partition centres. 50mm Isover Acoustic Partition
Roll (APR 1200) in the cavity. Roll (APR 1200) in the cavity.
Partitions

Linings as in table. Linings as in table.

4 5
C04

One layer of board each side of One layer of board each side of
Gypframe 70 S 50 ‘C’ Studs at 600mm Gypframe 70 S 50 ‘C’ Studs at 600mm
centres. 80mm Isover Modular Roll in centres. 75mm Isover Acoustic Slab in
the cavity. Linings as in table. the cavity. Linings as in table.

Detail Partition Board type Lining Max. Sound insulation Duty Approx. System
thickness thickness partition RwdB rating weight reference
mm mm height1 Any Skim kg/m²
mm Any finish2 Skim only3
finish2 only3

60 minutes fire resistance

1 102 Gyproc DuraLine 1 x 15 3800 42 - Severe 29 Q606062 -

2 102 Gyproc DuraLine 1 x 15 3800 47 48 Severe 29 Q606063 Q606063S

3 102 Gyproc DuraLine 1 x 15 3800 48 49 Severe 29 Q606064 Q606064S

4 102 Gyproc DuraLine 1 x 15 3800 49 50 Severe 29 Q606065 Q606065S

5 102 Gyproc DuraLine 1 x 15 3800 50 51 Severe 29 Q606066 Q606066S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

C04. S03. P03 british-gypsum.com


GypWall robust performance (continued)

GypWall robust
For details of when
to specify fire
70mm Gypframe 'C' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 1b — Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2 3

One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 70 S 50 ‘C’ Studs at 600mm Gypframe 70 S 50 ‘C’ Studs at 600mm Gypframe 70 S 50 ‘C’ Studs at 600mm
centres. Linings as in table. centres. 25mm Isover Acoustic Partition centres. 50mm Isover Acoustic Partition
Roll (APR 1200) in the cavity. Roll (APR 1200) in the cavity.

Partitions
Linings as in table. Linings as in table.

4 5

C04
One layer of board each side of One layer of board each side of
Gypframe 70 S 50 ‘C’ Studs at 600mm Gypframe 70 S 50 ‘C’ Studs at 600mm
centres. 80mm Isover Modular Roll in centres. 75mm Isover Acoustic Slab in
the cavity. Linings as in table. the cavity. Linings as in table.

Detail Partition Board type Lining Max. Sound insulation Duty Approx. System
thickness thickness partition RwdB rating weight reference
mm mm height1 Any Skim kg/m²
mm Any finish2 Skim only3
finish2 only3

60 minutes fire resistance

1 102 Gyproc DuraLine 1 x 15 3800 42 - Severe 29 Q606062 -

2 102 Gyproc DuraLine 1 x 15 3800 47 48 Severe 29 Q606063 Q606063S

3 102 Gyproc DuraLine 1 x 15 3800 48 49 Severe 29 Q606064 Q606045S

4 102 Gyproc DuraLine 1 x 15 3800 49 50 Severe 29 Q606065 Q606065S

5 102 Gyproc DuraLine 1 x 15 3800 50 51 Severe 29 Q606066 Q606066S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S03. P04


GypWall robust performance (continued)
GypWall robust

For details of when


to specify fire
70mm Gypframe 'I' Studs - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 2a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3 4

One layer of board each side of One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 70 I 50 ‘I’ Studs at 600mm Gypframe 70 I 50 ‘I’ Studs at 600mm Gypframe 70 I 50 ‘I’ Studs at 600mm Gypframe 70 I 50 ‘I’ Studs at 600mm
centres. Linings as in table. centres. 25mm Isover Acoustic Partition centres. 50mm Isover Acoustic Partition centres. 80mm Isover Modular Roll in
Roll (APR 1200) in the cavity. Roll (APR 1200) in the cavity. the cavity. Linings as in table.
Linings as in table. Linings as in table.
Partitions

Detail Partition Board type Lining Max. Sound Duty rating Approx. System
thickness thickness partition insulation weight reference
mm mm height1 RwdB kg/m²
mm
C04

60 minutes fire resistance

1 102 Gyproc DuraLine 1 x 15 4200 42 Severe 29 Q606049

2 102 Gyproc DuraLine 1 x 15 4200 47 Severe 29 Q606050

3 102 Gyproc DuraLine 1 x 15 4200 48 Severe 29 Q606051

4 102 Gyproc DuraLine 1 x 15 4200 50 Severe 29 Q606052

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

2
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

C04. S03. P05 british-gypsum.com


GypWall robust performance (continued)

GypWall robust
For details of when
to specify fire
70mm Gypframe 'I' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 2b — Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2 3 4

One layer of board each side of One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 70 I 50 ‘I’ Studs at 600mm Gypframe 70 I 50 ‘I’ Studs at 600mm Gypframe 70 I 50 ‘I’ Studs at 600mm Gypframe 70 I 50 ‘I’ Studs at 600mm
centres. Linings as in table. centres. 25mm Isover Acoustic Partition centres. 50mm Isover Acoustic Partition centres. 80mm Isover Modular Roll in
Roll (APR 1200) in the cavity. Roll (APR 1200) in the cavity. the cavity. Linings as in table.
Linings as in table. Linings as in table.

Partitions
Detail Partition Board type Lining Max. Sound Duty rating Approx. System
thickness thickness partition insulation weight reference
mm mm height1 RwdB kg/m²
mm

C04
60 minutes fire resistance

1 102 Gyproc DuraLine 1 x 15 4300 42 Severe 29 Q606049

2 102 Gyproc DuraLine 1 x 15 4300 47 Severe 29 Q606050

3 102 Gyproc DuraLine 1 x 15 4300 48 Severe 29 Q606051

4 102 Gyproc DuraLine 1 x 15 4300 50 Severe 29 Q606052

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of reduced stud centres. Maximum partition height can be
increased to 4700mm by using Gypframe 70 I 70 'I' Studs. Refer to C04. S01. P05, Table 2.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S03. P06


GypWall robust performance (continued)
GypWall robust

For details of when


to specify fire
70mm Gypframe AcouStuds - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 3a — Solutions to satisfy the requirements of BS EN 1364-1

1 2

One layer of board each side of One layer of board each side of
Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at
600mm centres. 25mm Isover Acoustic 600mm centres. 50mm Isover Acoustic
Partition Roll (APR 1200) in the cavity. Partition Roll (APR 1200) in the cavity.
Linings as in table. Linings as in table.
Partitions

Detail Partition Board type Lining Max. Sound insulation Duty Approx. System
thickness thickness partition RwdB rating weight reference
mm mm height1 Any Skim kg/m²
mm Any finish2 Skim only3
finish2 only3
C04

60 minutes fire resistance

1 102 Gyproc DuraLine 1 x 15 4000 48 49 Severe 29 Q606A044 Q606A044S

2 102 Gyproc DuraLine 1 x 15 4000 50 51 Severe 29 Q606A046 Q606A046S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

C04. S03. P07 british-gypsum.com


GypWall robust performance (continued)

GypWall robust
For details of when
to specify fire
70mm Gypframe AcouStuds - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 3b — Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2

One layer of board each side of One layer of board each side of
Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at
600mm centres. 25mm Isover Acoustic 600mm centres. 50mm Isover Acoustic
Partition Roll (APR 1200) in the cavity. Partition Roll (APR 1200) in the cavity.
Linings as in table. Linings as in table.

Partitions
Detail Partition Board type Lining Max. Sound insulation Duty Approx. System
thickness thickness partition RwdB rating weight reference
mm mm height1 Any Skim kg/m²
mm Any finish2 Skim only3
finish2 only3

C04
60 minutes fire resistance

1 102 Gyproc DuraLine 1 x 15 4000 48 49 Severe 29 Q606A044 Q606A044S

2 102 Gyproc DuraLine 1 x 15 4000 50 51 Severe 29 Q606A046 Q606A046S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S03. P08


GypWall robust performance (continued)
GypWall robust

For details of when


to specify fire
92mm Gypframe 'C' Studs - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 4a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 92 S 60 ‘C’ Studs at 600mm Gypframe 92 S 60 ‘C’ Studs at 600mm Gypframe 92 S 60 ‘C’ Studs at 600mm
centres. Linings as in table. centres. 25mm Isover Acoustic Partition centres. 3 x 25mm Isover Acoustic
Roll (APR 1200) in the cavity. Partition Roll (APR 1200) in the cavity.
Linings as in table. Linings as in table.
Partitions

Detail Partition Board type Lining Max. Sound insulation Duty Approx. System
thickness thickness partition RwdB rating weight reference
mm mm height1 Any Skim kg/m²
Any finish2 Skim only3
C04

mm finish2 only3

60 minutes fire resistance

1 124 Gyproc DuraLine 1 x 15 4000 45 46 Severe 29 A206257 A206257S

2 124 Gyproc DuraLine 1 x 15 4000 484 49 4 Severe 30 A206258 A206258S

3 124 Gyproc DuraLine 1 x 15 4000 52 53 Severe 30 Q606057 Q606057S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

C04. S03. P09 british-gypsum.com


GypWall robust performance (continued)

GypWall robust
For details of when
to specify fire
92mm Gypframe 'C' Studs - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 4b — Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2 3

One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 92 S 60 ‘C’ Studs at 600mm Gypframe 92 S 60 ‘C’ Studs at 600mm Gypframe 92 S 60 ‘C’ Studs at 600mm
centres. Linings as in table. centres. 25mm Isover Acoustic Partition centres. 3 x 25mm Isover Acoustic
Roll (APR 1200) in the cavity. Partition Roll (APR 1200) in the cavity.
Linings as in table. Linings as in table.

Partitions
Detail Partition Board type Lining Max. Sound insulation Duty Approx. System
thickness thickness partition RwdB rating weight reference
mm mm height1 Any Skim kg/m²

C04
mm Any finish2 Skim only3
finish2 only3

60 minutes fire resistance

1 124 Gyproc DuraLine 1 x 15 4900 45 46 Severe 29 A206257 A206257S

2 124 Gyproc DuraLine 1 x 15 4900 48 4


49 4
Severe 30 A206258 A206258S

3 124 Gyproc DuraLine 1 x 15 4900 52 53 Severe 30 Q606057 Q606057S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of reduced stud centres.
Refer to C04. S01. P05, Table 2. Maximum partition height can be increased to 6200mm by using Gypframe 92 I 90 'I' Studs.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
Increasing insulation to 50mm Isover Acoustic Partition Roll (APR 1200) will not improve this system performance.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S03. P10


GypWall robust performance (continued)
GypWall robust

For details of when


to specify fire
92mm Gypframe AcouStuds - single layer board linings resistance using EN
Refer to C02. S01. P05
Table 5a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

One layer of board each side of 92mm One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe AcouStuds at 600mm centres. Gypframe AcouStuds at 600mm centres. Gypframe AcouStuds at 600mm centres.
Linings as in table. 25mm Isover Acoustic Partition Roll 50mm Isover Acoustic Partition Roll
(APR 1200) in the cavity. Linings as in table. (APR 1200) in the cavity. Linings as in table.
Partitions

Detail Partition Board type Lining Max. Sound insulation Duty Approx. System
thickness thickness partition RwdB rating weight reference
mm mm height1 Any Skim kg/m²
mm Any finish2 Skim only3
finish2 only3
C04

60 minutes fire resistance

1 124 Gyproc DuraLine 1 x 15 4000 45 46 Severe 29 A206A277 A206A277S

2 124 Gyproc DuraLine 1 x 15 4000 50 51 Severe 30 A206A278 A206A278S

3 124 Gyproc DuraLine 1 x 15 4000 52 53 Severe 30 A206A279 A206A279S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

C04. S03. P11 british-gypsum.com


GypWall robust performance (continued)

GypWall robust
For details of when
to specify fire
92mm Gypframe AcouStuds - single layer board linings resistance using BS
Refer to C02. S01. P05
Table 5b — Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2 3

One layer of board each side of 92mm One layer of board each side of 92mm One layer of board each side of 92mm
Gypframe AcouStuds at 600mm centres. Gypframe AcouStuds at 600mm centres. Gypframe AcouStuds at 600mm centres.
Linings as in table. 25mm Isover Acoustic Partition Roll 50mm Isover Acoustic Partition Roll
(APR 1200) in the cavity. Linings as in table. (APR 1200) in the cavity. Linings as in table.

Partitions
Detail Partition Board type Lining Max. Sound insulation Duty Approx. System
thickness thickness partition RwdB rating weight reference
mm mm height1 Any Skim kg/m²
mm Any finish2 Skim only3
finish2 only3

C04
60 minutes fire resistance

1 124 Gyproc DuraLine 1 x 15 4900 45 46 Severe 29 A206A277 A206A277S

2 124 Gyproc DuraLine 1 x 15 4900 50 51 Severe 30 A206A278 A206A278S

3 124 Gyproc DuraLine 1 x 15 4900 52 53 Severe 30 A206A279 A206A279S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S03. P12


GypWall robust performance (continued)
GypWall robust

For details of when


to specify fire
70mm Gypframe AcouStuds - double layer board linings resistance using EN
Refer to C02. S01. P05
Table 6a — Solutions to satisfy the requirements of BS EN 1364-1

1 2

One inner layer and one outer layer of One inner layer and one outer layer of
board each side of Gypframe 70 AS 50 board each side of Gypframe 70 AS 50
AcouStuds at 600mm centres. AcouStuds at 600mm centres. 25mm
Linings as in table.
Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.
Partitions

Detail Partition Inner board type Outer board type Max. Sound insulation Duty Approx. System
thickness mm mm partition RwdB rating weight reference
mm height1 Any Skim kg/m²
Any Skim
mm
C04

finish2 only3 finish2 only3

90 minutes fire resistance

Gyproc SoundBloc Gyproc DuraLine


2 127 4700 57 58 Severe 52 Q606A063 Q606A063S
1 x 12.5 1 x 15

120 minutes fire resistance

Gyproc SoundBloc Gyproc DuraLine


1 127 4700 53 - Severe 51 Q606A062 -
1 x 12.5 1 x 15

Gyproc SoundBloc Gyproc DuraLine


2 127 3000 57 58 Severe 52 Q606A063 Q606A063S
1 x 12.5 1 x 15

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

C04. S03. P13 british-gypsum.com


GypWall robust performance (continued)

GypWall robust
For details of when
to specify fire
70mm Gypframe AcouStuds - double layer board linings resistance using BS
Refer to C02. S01. P05
Table 6b — Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2

One inner layer and one outer layer of One inner layer and one outer layer of
board each side of Gypframe 70 AS 50 board each side of Gypframe 70 AS 50
AcouStuds at 600mm centres. AcouStuds at 600mm centres. 25mm
Linings as in table.
Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table.

Partitions
Detail Partition Inner board type Outer board type Max. Sound insulation Duty Approx. System
thickness mm mm partition RwdB rating weight reference
mm height1 Any Skim kg/m²
Any Skim
mm

C04
finish2 only3 finish2 only3

120 minutes fire resistance

Gyproc SoundBloc Gyproc DuraLine


1 127 4700 53 - Severe 51 Q606A062 -
1 x 12.5 1 x 15

Gyproc SoundBloc Gyproc DuraLine


2 127 4700 57 58 Severe 52 Q606A063 Q606A063S
1 x 12.5 1 x 15

Gyproc SoundBloc Gyproc DuraLine


1 132 5000 53 54 Severe 55 Q606A064 Q606A064S
1 x 15 1 x 15

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved through the use of reduced stud centres.
Refer to C04. S01. P05, Table 2.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.

The fire resistance and sound insulation performances are for imperforate partitions, but incorporating deflection heads, with all joints taped and filled
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to
deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S03. P14


GypWall robust design
GypWall robust

Building design Door openings

Whilst our GypWall partitions are non-loadbearing, they are able to The designer should consider the thickness tolerances of the
provide resistance to levels of horizontal uniformly distributed loads partition types in relation to the proposed door frame detail. To
in accordance with BS 6399. satisfy BS 5234: Part 2 requirements for Heavy and Severe Duty
Rating partitions, door framing should be specified. The door
Refer to C02. S01. P26 – Robustness.
manufacturer should also be consulted in relation to the door detail.

Planning – key factors Refer to construction detail 7 in this section..

GypWall robust comprises Gypframe 'C' Studs installed at 600mm


centres within Gypframe Deep Flange Floor & Ceiling Channels. The
position of services and heavy fixtures should be pre-determined
and their installation planned into the frame erection stage. Important information
Partitions

Fixing floor and ceiling channels Particular care must be taken in selecting
the correct length of British Gypsum
Gypframe Deep Flange Floor & Ceiling Channels must be securely Drywall Screws for fixing Gyproc DuraLine
fixed with a row of fixings at 600mm maximum centres. For 94mm to Gypframe AcouStuds to ensure that
channels and above, two rows of staggered fixings are required, they do not penetrate the web of the
C04

each row at 600mm centres and each fixing 25mm in from the stud. Doing so would create a physical
flange. If the floor is uneven, a 38mm thick timber sole plate equal bridge that would lead to a downgrade in
to the width of the channel should be used. sound insulation performance.

If the concrete or screeded floor is new, consideration should be


given to the installation of a damp-proof membrane between the Framing surround for openings
floor surface and the channel or sole plate.
Where services such as horizontal ducts, fire dampers and access
panels are required to penetrate the wall, their position should be
pre-determined in order that a framed opening can be provided.
Important information The openings should be constructed using established metal stud
procedures.
Gypframe Deep Flange Floor & Ceiling Refer to Partitions introduction C04. S01. P16 – construction
Channels (DC) must be used with all details 28-31.
GypWall robust systems.
Refer to GypWall robust – construction Cavity barriers
details 1 and 2. Minimum 12.5mm Gyproc plasterboard screw-fixed into the web
of perimeter channels or vertical studs will provide a satisfactory
closure to flame or smoke.
Splicing Refer to C06. S07. P02 – Cavity barriers.
To extend studs, overlap by 600mm (minimum). Fix together using
British Gypsum Wafer Head Drywall Screws or steel pop rivets (two Control joints
to each flange), or by using the Gyproc Stud Interlocking Tool twice Control joints may be required in the partition to relieve stresses
to each flange. induced by expansion and contraction of the structure. They should
Refer to Partitions introduction C04. S01. P07 – construction coincide with movement joints within the surrounding structure.
detail 1.
Deflection heads

Partition to structural steelwork junctions Partition head deflection designs may be necessary to
accommodate deflections in the supporting floor. Deflection heads
When designing the layout of rooms requiring separation by sound
may also be required to the underside of roof structures subjected
insulating walls abutting structural steelwork, consideration should
to positive and negative pressures.
be given to the potential loss of sound insulation performance
through the steelwork.
To minimise the loss of acoustic performance:
Refer to C02. S01. P10 – Building acoustics.
Refer to C02. S01. P10 – Building acoustics.

For deflection head design:

Refer to Partitions introduction C04. S01. P11 – construction


details 15 - 22.

C04. S03. P15 british-gypsum.com


GypWall robust design (continued)

GypWall robust
Services Access for maintenance

Penetrations Gyproc Profilex Access Panels are available to provide access for
Penetrations of fire-resistant or sound-insulating constructions maintenance. Access panels must be fully compatible with drywall
for services need careful consideration to ensure that the construction and match the fire rating of the partition.
performance of the element is not downgraded. Consideration also
Refer to profilex.co.uk for further information.
needs to be given to the services themselves so they do not act as
the mechanism of fire spread or sound transmission.
Board finishing
Refer to C02. S01. P32 – Service installations. Refer to C08. S01. P02 – Finishes.

Electrical
The installation of electrical services should be carried out in
accordance with BS 7671. The cut-outs in the studs can be used for
Handy hint

Partitions
routing electrical and other small services.
For increased resistance to accidental surface
Refer to Partitions introduction C04. S01. P07 – construction damage, the use of ThistlePro DuraFinish is
detail 2. recommended.

C04
Switch boxes and socket outlets can be supported from
Gypframe 99 FC 50 Fixing Channel fixed horizontally between studs, Tiling
or a high performance socket box detail where higher acoustic Tiles can be applied to the surface of lightweight partition systems.
performance is required.
Refer to C08. S04. P02 – Tiling.
Where Gypframe AcouStuds are used, services are routed through
50mm x 28mm ‘H’ shaped push-outs, at the same centres as shown Construction details
for conventional cut-outs.
For standard GypWall construction details
Refer to Partitions introduction C04. S01. P07 – construction
Refer to Partitions introduction C04. S01. P07 – construction
detail 2a.
details.

Cables should be protected by conduit, or other suitable precautions


For GypWall robust system specific construction details refer to the
taken to prevent abrasion when they pass through the metal frame.
following pages.

Handy hint
Where access is limited to one side at the
SpecSure®
head, e.g. M+E cages already installed in
All our systems are covered by SpecSure® when
corridors.
using genuine British Gypsum and Saint-Gobain
Refer to C05. S02. P02 – ShaftWall. Isover products.

Independent support
When designing for the installation of services such as fire dampers
and associated ductwork through a GypWall partition, consideration
should be given to the size and weight of the damper - this will
determine whether it can be supported directly from the partition
or needs to be independently supported from the structure.

Refer to Partitions introduction C04. S01. P17 – construction


details 29-31.

Fixtures

Lightweight fixtures can be made directly to the partition linings.


Medium weight fixtures can be made to Gypframe 99 FC 50 Fixing
Channel. Heavyweight fixtures (to BS 5234), such as wash basins
and wall cupboards, can be fixed using plywood secured with
Gypframe Service Support Plates.

Refer to C02. S01. P33 – Service installations.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S03. P16


GypWall robust construction details
GypWall robust

1 3 2
1
4

6
Partitions

3
C04

Head Base

3 4

1
1

Junction with masonry and stop end Corner

5 6

2
1

1
4

‘T’ Junction when partition with higher acoustic performance


abuts a partition with lower acoustic performance.
‘T’ junction Acoustic principles only - detail may not be suitable for all solutions

1 Gyproc DuraLine 6 Skirting


2 Gypframe ‘C’ Stud 7 Internal masonry
3 Gypframe Deep Flange Floor & Ceiling Channel 8 DriLyner basic wall lining system
4 Gyproc Sealant 9 Isover Acoustic Partition Roll (APR 1200)
5 Bulk fill with Gyproc jointing materials (where gap exceeds 5mm)

C04. S03. P17 british-gypsum.com


GypWall robust construction details

GypWall robust
7

Partitions
150mm
5

C04
7

4
300mm

1200mm 1200mm

1
150mm

Door frame (maximum 1200mm width) to satisfy BS 5234: Parts 1 & 2: 1992 - Heavy and Severe Duty (up to 60kg door)

1 Gyproc DuraLine 5 Gypframe 72 DC 60 Deep Channel cut and bent to form door head
2 Gypframe 70 S 50 'C' Stud 6 Timber door frame and architrave
3 Gypframe 70 S 50 'C' stud at jamb 7 Stud sleeved to full opening height with Gypframe 72 DC 60 Deep
4 Gypframe 72 DC 60 Deep Channel Channel

Advice should be sought from the door manufacturer prior to the construction of these details.

At the base, the channel is cut and bent to extend 300mm up the studs and fixed each side with two British Gypsum Wafer Head Drywall Screws. The
studs each side of the opening are sleeved full height of opening with Gypframe Floor & Ceiling Channel.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S03. P18


GypWall robust system components
GypWall robust

Gypframe metal components ( Refer to C10. S02. P02 for details)

Gypframe ‘C’ Studs (70 S 50, 92 S 60) Gypframe GFS1 Fixing Strap
Vertical stud providing acoustic and structural Used to support horizontal board joints and within
performances designed to receive fixing of board deflection heads.
to both sides.

Gypframe ‘I’ Studs (70 I 50, 70 I 70, 92 I 90) Gypframe GFT1 Fixing T
Enhanced strength stud that allows for lining height, Used to support horizontal board joints.
without increasing lining width. Designed to receive
fixing of board to both sides.
Partitions

Gypframe AcouStud (70 AS 50, 92 AS 50) Gypframe GA5 Internal Fixing Angle
Vertical stud providing enhanced acoustic and Steel angle providing framing stability and
structural performances designed to receive board support.
C04

fixing of board to both sides.

Gypframe Deep Flange Floor & Ceiling Channels Gypframe GA6 Splayed Angle
(72 DC 60, 94 DC 60) Steel angle providing framing stability and
Floor and ceiling channels with deep flanges for board support.
retaining the Gypframe studs at floor and ceiling
junctions for partitions 4200mm to 8000mm high.
Also used around openings and in deflection heads
(maximum 30mm deflection).

Gypframe Extra Deep Flange Floor & Ceiling Gypframe Service Support Plate
Channels (72 EDC 80, 94 EDC 70) For installation of 18mm plywood within
Floor and ceiling channels with extra deep flanges a partition cavity to support medium to
for retaining the Gypframe studs at floor and ceiling heavyweight fixtures.
junctions for partitions over 8000mm high. Also used
around openings and in deflection heads (maximum
50mm deflection).

Gypframe 99 FC 50 Fixing Channel


A versatile metal fixing channel used to support
medium weight fixtures on walls.

Board products ( Refer to C10. S03. P02 for details)

Gyproc DuraLine1 Glasroc F firecase


Gypsum plasterboard with fire resistant additives Non-combustible glass-reinforced gypsum board.
and a high density core for enhanced sound Used to form deflection head.
insulation and impact resistance performance.

Gyproc SoundBloc1 Gyproc CoreBoard


Gypsum plasterboard with a high density core for Gypsum plasterboard with fire and moisture
enhanced sound insulation performance. resistant additives. Used to form deflection head.

1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

C04. S03. P19 british-gypsum.com


GypWall robust
GypWall robust system components (continued)

Fixing products ( Refer to C10. S04. P02 for details)

British Gypsum Drywall Screws British Gypsum Jack-Point Screws


Corrosion resistant self-tapping steel screws for Corrosion resistant self-tapping steel screws
fixing board to metal framing less than 0.8mm for fixing board to metal framing 0.8mm thick and
thick ('I' Studs less than 0.6mm thick). greater (‘I’ stud 0.6mm thick and greater).

British Gypsum Collated Drywall Screws British Gypsum Wafer Head Jack-Point Screws
Corrosion resistant self-tapping steel screws for Corrosion resistant self-tapping steel screws
fixing board to metal framing less than 0.8mm for fixing metal to metal framing 0.8mm thick and
thick ('I' Studs less than 0.6mm thick). greater ('I' Studs 0.8mm thick and greater).

Partitions
British Gypsum Wafer Head Drywall Screws
Corrosion resistant self-tapping steel screws for
fixing metal to metal framing less than 0.8mm

C04
thick ('I' Studs less than 0.6mm thick).

Plasterboard accessories ( Refer to C10. S05. P02 for details)

Gyproc Jointing Material Gyproc edge and angle beads


Jointing compounds, ready mixes and adhesives Protecting and enhancing board edges and corners
for reinforcement and finishing of board joints.
Primers and sealers for treatment of boards for
pre-decoration.

Gyproc FireStrip Gyproc Sealant


A soft extruded linear intumescent gap sealer Used to seal air paths for optimum sound
to maintain fire resistance located directly to insulation.
the underside of the soffit when forming a
deflection head.

Gyproc Control Joint Gyproc Joint Tape


To accommodate structural movement of up A paper tape designed for reinforcement of flat
to 7mm. joints or internal angles.

Finishing products ( Refer to C10. S06. P02 for details)

Thistle MultiFinish ThistlePro DuraFinish


To provide a plaster skim finish on most common To provide a plaster skim finish and provide up to
backgrounds including undercoat plasters and 60% tougher resistance to accidental damage.
plasterboard. Can provide enhanced acoustic
performance.

Thistle BoardFinish ThistlePro PureFinish


To provide a plaster skim finish to To provide a plaster skim finish with
Gyproc plasterboards. ACTIVair technology. Used to finish most
common backgrounds including undercoat plasters
and plasterboard. For more information refer to
C02. S01. P49.

Thistle SprayFinish ThistlePro Magnetic


To provide a plaster skim finish by spray or hand To provide a plaster skim finish that provides an
application, ideal for medium to large projects. attraction to magnets used to finish a wide range
of backgrounds, including undercoat plasters and
plasterboard.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S03. P20


GypWall robust

GypWall robust system components (continued)

Finishing products ( Refer to C10. S06. P02 for details)

Thistle ProTape FT50 Plaster accessories


Self-adhesive 48mm wide glass fibre mesh tape. Designed for the reinforcement and finishing of
board joints before plaster skimming.

Thistle ProTape FT100


Self-adhesive 100mm wide glass fibre mesh tape.
Partitions

Insulation products ( Refer to C10. S09. P02 for details)

Isover Acoustic Partition Roll (APR 1200) Isover Modular Roll


Glass mineral wool for enhanced acoustic Glass mineral wool for enhanced acoustic
performance. performance.
C04

Isover Acoustic Slab


Glass mineral wool to achieve acoustic
performance.

C04. S03. P21 british-gypsum.com


GypWall robust installation overview

GypWall robust
This is intended to be a basic description of how the system is built.
For detailed installation guidance refer to the British Gypsum Site Book.

Partitions
Gypframe Deep Flange or Extra Deep Flange Gypframe Studs are suitably fixed to The perimeter of the partition is then sealed
Floor & Ceiling Channels are suitably fixed abutments. on both sides with Gyproc Sealant.
to the floor and soffit.

C04
Gypframe Studs are then friction fitted into Door openings are constructed to the Heavy M&E services can be located within the
the Gypframe Floor & Ceiling Channels at and Severe door detail. partition cavity.
the required centres.

Isover insulation can also be added to Gyproc DuraLine (and Gyproc SoundBloc
the partition cavity for increased acoustic inner layer if required) plasterboards are
performance. then fixed to the Gypframe framework with
British Gypsum Drywall Screws.

Additional information
For full installation details, refer to the
British Gypsum Site Book, available to
download from british-gypsum.com

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S03. P22


GypWall extreme

GypWall extreme
Ultimate impact and abrasion resistant partition system

All our systems are covered by SpecSure® when using


genuine British Gypsum and Saint-Gobain Isover products
Partitions
C04
GypWall extreme
GypWall extreme
GypWall extreme is our ultimate impact resistant
30 60
partition, incorporating Rigidur h reinforced mins

gypsum board with its extremely high levels of


impact and abrasion resistance, in combination
with high-strength Gypframe components, 44 62
results in a range of partition systems with RwdB

durability that will exceed expectations.

Partitions
The GypWall extreme family of partitions have Refer to C02. S01. P49

been tested to the extreme, comfortably

C04
surpassing all requirements of a full Severe Duty
Rating in accordance with BS 5234: Part 2: 1992. Refer to C01. S01. P07

Key benefits
— Provides performance beyond a Severe Duty
Rating from a lightweight, narrow-footprint
solution
— Heavy fixtures can be secured to a single layer
without the need for additional pattressing
— Reduced maintenance cycles due to a highly
impact and scratch resistant board surface
— Fully compatible with other British Gypsum
systems, meaning GypWall extreme can be
specified in areas of the building that really
need it

Handy hint
For areas of a building where extreme levels of duty are required
to only one side of the construction, for example a partition
between a corridor and a classroom, refer to C04. S04. P08
GypWall extreme / robust hybrid system performance tables.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S04. P02


GypWall extreme performance
GypWall extreme

For details of when


to specify fire
70mm Gypframe ‘C’ Stud and Gypframe AcouStud resistance using EN
Refer to C02. S01. P05
Table 1a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 70 S 60 ‘C’ Studs at 600mm Gypframe 70 S 60 ‘C’ Studs at 600mm Gypframe 70 S 60 ‘C’ Studs at 600mm
centres. Linings as in table. centres. 25mm Isover Acoustic Partition centres. 50mm Isover Acoustic Partition
Roll (APR 1200) in the cavity. Roll (APR 1200) in the cavity.
Linings as in table. Linings as in table.
Partitions

4 5
C04

Two layers of board each side of Two layers of board each side of
Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at
600mm centres. Linings as in table. 600mm centres. 25mm Isover Acoustic
Partition Roll (APR 1200) in the cavity.
Linings as in table.

Detail Partition Inner board type ACTIVair Outer board ACTIVair Max. Sound Duty Approx. System
thickness mm technology type technology partition insulation rating weight reference
mm available1 mm available1 height2 Rw dB kg/m²
mm

30 minutes fire resistance

1 97 Rigidur h 12.5  - - 3800 43 Severe3 30 X606009

2 97 Rigidur h 12.5  - - 3800 46 Severe 3


30 X606010

3 97 Rigidur h 12.5  - - 3800 49 Severe 3


30 X606011

1 102 Rigidur h 15  - - 4000 43 Severe3 36 X606001

2 102 Rigidur h 15  - - 4000 48 Severe 3


36 X606002

3 102 Rigidur h 15  - - 4000 48 Severe 3


36 X606003

60 minutes fire resistance

4 122 Gyproc SoundBloc 12.5 - Rigidur h 12.5  4000 54 Severe3 52 X606A006

4 127 Gyproc WallBoard 15 - Rigidur h 12.5  4000 54 Severe 3


52 X606A005

5 127 Gyproc SoundBloc 15 - Rigidur h 12.5  4000 58 Severe3 56 X606A007

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
These systems have an ACTIVair board option available, which improves indoor air quality. Alternatively, all systems can be skim finished
with ThistlePro PureFinish, which contains ACTIVair technology. Refer to C08. S02. P05 and C02. S01. P49 for further details.
2
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
3
The resistance to impact of Rigidur h is higher than the most severe criteria set out in BS 5234. British Gypsum has conducted a number of additional
structural performance and durability tests beyond Severe Duty to better reflect actual use in high traffic areas. Search for substantiation report on
british-gypsum.com and type in the reference number.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S04. P03 british-gypsum.com


GypWall extreme performance (continued)

GypWall extreme
For details of when
to specify fire
70mm Gypframe ‘C’ Stud and Gypframe AcouStud resistance using BS
Refer to C02. S01. P05
Table 1b — Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2 3

One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 70 S 60 ‘C’ Studs at 600mm Gypframe 70 S 60 ‘C’ Studs at 600mm Gypframe 70 S 60 ‘C’ Studs at 600mm
centres. Linings as in table. centres. 25mm Isover Acoustic Partition centres. 50mm Isover Acoustic Partition
Roll (APR 1200) in the cavity. Roll (APR 1200) in the cavity.
Linings as in table. Linings as in table.

Partitions
4 5

C04
Two layers of board each side of Two layers of board each side of
Gypframe 70 AS 50 AcouStuds at Gypframe 70 AS 50 AcouStuds at
600mm centres. Linings as in table. 600mm centres. 25mm Isover Acoustic
Partition Roll (APR 1200) in the cavity.
Linings as in table.

Detail Partition Inner board type ACTIVair Outer board ACTIVair Max. Sound Duty Approx. System
thickness mm technology type technology partition insulation rating weight reference
mm available1 mm available1 height2 Rw dB kg/m²
mm

30 minutes fire resistance

1 97 Rigidur h 12.5  - - 3800 43 Severe3 30 X606009

2 97 Rigidur h 12.5  - - 3800 46 Severe 3


30 X606010

3 97 Rigidur h 12.5  - - 3800 49 Severe 3


30 X606011

1 102 Rigidur h 15  - - 4000 43 Severe3 36 X606001

2 102 Rigidur h 15  - - 4000 48 Severe 3


36 X606002

3 102 Rigidur h 15  - - 4000 48 Severe 3


36 X606003

60 minutes fire resistance

4 122 Gyproc SoundBloc 12.5 - Rigidur h 12.5  4700 54 Severe3 52 X606A006

4 127 Gyproc WallBoard 15 - Rigidur h 12.5  4700 54 Severe 3


52 X606A005

5 127 Gyproc SoundBloc 15 - Rigidur h 12.5  4700 58 Severe3 56 X606A007

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
These systems have an ACTIVair board option available, which improves indoor air quality. Alternatively, all systems can be skim finished
with ThistlePro PureFinish, which contains ACTIVair technology. Refer to C08. S02. P05 and C02. S01. P49 for further details.
2
Based on a limiting deflection of L/240 at 200 Pa.
3
The resistance to impact of Rigidur h is higher than the most severe criteria set out in BS 5234. British Gypsum has conducted a number of additional
structural performance and durability tests beyond Severe Duty to better reflect actual use in high traffic areas. Search for substantiation report on
british-gypsum.com and type in the reference number.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S04. P04


GypWall extreme performance (continued)
GypWall extreme

For details of when


to specify fire
146mm Gypframe AcouStud resistance using EN
Refer to C02. S01. P05
Table 2a — Solutions to satisfy the requirements of BS EN 1364-1

Two layers of board each side of


Gypframe 146 AS 50 AcouStuds at
600mm centres. 25mm Isover Acoustic
Partitions

Partition Roll (APR 1200) in the cavity.


Linings as in table.

Detail Partition Inner board type ACTIVair Outer board ACTIVair Max. Sound Duty Approx. System
thickness mm technology type technology partition insulation rating weight reference
C04

mm available mm available1 height2 Rw (Rw + Ctr ) kg/m²


mm dB

60 minutes fire resistance

1 203 Gyproc SoundBloc 15 - Rigidur h 12.5  4000 60 (57) Severe3 56 X606A013

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
These systems have an ACTIVair board option available, which improves indoor air quality. Alternatively, all systems can be skim finished
with ThistlePro PureFinish, which contains ACTIVair technology. Refer to C08. S02. P05 and C02. S01. P49 for further details.
2
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
3
The resistance to impact of Rigidur h is higher than the most severe criteria set out in BS 5234. British Gypsum has conducted a number of additional
structural performance and durability tests beyond Severe Duty to better reflect actual use in high traffic areas. Search for substantiation report on
british-gypsum.com and type in the reference number.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S04. P05 british-gypsum.com


GypWall extreme performance (continued)

GypWall extreme
For details of when
to specify fire
146mm Gypframe AcouStud resistance using BS
Refer to C02. S01. P05
Table 2b ­— Solutions to satisfy requirements of BS 476: Part 22: 1987

Two layers of board each side of


Gypframe 146 AS 50 AcouStuds at
600mm centres. 25mm Isover Acoustic

Partitions
Partition Roll (APR 1200) in the cavity.
Linings as in table.

Detail Partition Inner board type ACTIVair Outer board ACTIVair Max. Sound Duty Approx. System
thickness mm technology type technology partition insulation rating weight reference

C04
mm available mm available1 height2 Rw (Rw + Ctr ) kg/m²
mm dB

60 minutes fire resistance

1 203 Gyproc SoundBloc 15 - Rigidur h 12.5  7800 60 (57) Severe3 56 X606A013

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
These systems have an ACTIVair board option available, which improves indoor air quality. Alternatively, all systems can be skim finished
with ThistlePro PureFinish, which contains ACTIVair technology. Refer to C08. S02. P05 and C02. S01. P49 for further details.
2
Based on a limiting deflection of L/240 at 200 Pa.
3
The resistance to impact of Rigidur h is higher than the most severe criteria set out in BS 5234. British Gypsum has conducted a number of additional
structural performance and durability tests beyond Severe Duty to better reflect actual use in high traffic areas. Search for substantiation report on
british-gypsum.com and type in the reference number.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S04. P06


GypWall extreme / robust hybrid performance
GypWall extreme

For details of when


to specify fire
70mm Gypframe 'C' Stud and Gypframe AcouStud resistance using EN
Refer to C02. S01. P05
Table 3a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3 4

One layer of board each side of One layer of board each side of One layer of board to side 1 and two One layer of board to side 1 and two
Gypframe 70 S 60 ‘C’ Studs at 600mm Gypframe 70 S 60 ‘C’ Studs at 600mm layers of board to side 2 of Gypframe layers of board to side 2 of Gypframe
centres. Linings as in table. centres. 50mm Isover Acoustic Partition 70 AS 50 AcouStuds at 600mm centres. 70 AS 50 AcouStuds at 600mm centres.
Roll (APR 1200) in the cavity. Linings as in table. 50mm Isover Acoustic Partition Roll
Linings as in table. (APR 1200) in the cavity.
Linings as in table.
Partitions

Detail Partition Board type and ACTIVair Board type and ACTIVair Max. Sound Duty Approx. System
thickness thickness (side 1) technology thickness (side 2) technology partition insulation rating weight reference
mm mm available mm available1 height2 Rw dB kg/m²
C04

mm

30 minutes fire resistance

1 102 Gyproc DuraLine 15 - Rigidur h 15  4000 45 Severe3 33 X606017

2 102 Gyproc DuraLine 15 - Rigidur h 15  4000 50 Severe 3


33 X606018

Gyproc WallBoard 15 -
3 115 Gyproc DuraLine 15 -
+ Rigidur h 12.5  4200 47 Severe3 40 X606A019

Gyproc SoundBloc 15 -
3 -
115 Gyproc DuraLine 15
+ Rigidur h 12.5  4200 49 Severe3 44 X606A021

Gyproc WallBoard 15 -
4 115 Gyproc DuraLine 15 -
+ Rigidur h 12.5  4200 52 Severe3 40 X606A020

Gyproc SoundBloc 15 -
4 -
115 Gyproc DuraLine 15
+ Rigidur h 12.5  4200 55 Severe3 44 X606A022

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
These systems have an ACTIVair board option available, which improves indoor air quality. Alternatively, all systems can be skim finished
with ThistlePro PureFinish, which contains ACTIVair technology. Refer to C08. S02. P05 and C02. S01. P49 for further details.
2
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
3
The resistance to impact of Rigidur h is higher than the most severe criteria set out in BS 5234. British Gypsum has conducted a number of additional
structural performance and durability tests beyond Severe Duty to better reflect actual use in high traffic areas. Search for substantiation report on
british-gypsum.com and type in the reference number.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S04. P07 british-gypsum.com


GypWall extreme / robust hybrid performance (continued)

GypWall extreme
For details of when
to specify fire
70mm Gypframe 'C' Stud and Gypframe AcouStud resistance using BS
Refer to C02. S01. P05
Table 3b - Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2 3 4

One layer of board each side of One layer of board each side of One layer of board to side 1 and two One layer of board to side 1 and two
Gypframe 70 S 60 ‘C’ Studs at 600mm Gypframe 70 S 60 ‘C’ Studs at 600mm layers of board to side 2 of Gypframe layers of board to side 2 of Gypframe
centres. Linings as in table. centres. 50mm Isover Acoustic Partition 70 AS 50 AcouStuds at 600mm centres. 70 AS 50 AcouStuds at 600mm centres.
Roll (APR 1200) in the cavity. Linings as in table. 50mm Isover Acoustic Partition Roll
Linings as in table. (APR 1200) in the cavity.
Linings as in table.

Partitions
Detail Partition Board type and ACTIVair Board type and ACTIVair Max. Sound Duty Approx. System
thickness thickness (side 1) technology thickness (side 2) technology partition insulation rating weight reference
mm mm available mm available1 height2 Rw dB kg/m²

C04
mm

30 minutes fire resistance

1 102 Gyproc DuraLine 15 - Rigidur h 15  4000 45 Severe3 33 X606017

2 102 Gyproc DuraLine 15 - Rigidur h 15  4000 50 Severe 3


33 X606018

Gyproc WallBoard 15 -
3 115 Gyproc DuraLine 15 -
+ Rigidur h 12.5  4200 47 Severe3 40 X606A019

Gyproc SoundBloc 15 -
3 -
115 Gyproc DuraLine 15
+ Rigidur h 12.5  4200 49 Severe3 44 X606A021

Gyproc WallBoard 15 -
4 115 Gyproc DuraLine 15 -
+ Rigidur h 12.5  4200 52 Severe3 40 X606A020

Gyproc SoundBloc 15 -
4 -
115 Gyproc DuraLine 15
+ Rigidur h 12.5  4200 55 Severe3 44 X606A022

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
These systems have an ACTIVair board option available, which improves indoor air quality. Alternatively, all systems can be skim finished
with ThistlePro PureFinish, which contains ACTIVair technology. Refer to C08. S02. P05 and C02. S01. P49 for further details.
2
Based on a limiting deflection of L/240 at 200 Pa.
3
The resistance to impact of Rigidur h is higher than the most severe criteria set out in BS 5234. British Gypsum has conducted a number of additional
structural performance and durability tests beyond Severe Duty to better reflect actual use in high traffic areas. Search for substantiation report on
british-gypsum.com and type in the reference number.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

Gypframe Deep Flange Floor & Ceiling Channel or Gypframe Extra Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S04. P08


GypWall extreme design
GypWall extreme

Building design Control joints

Whilst our GypWall partition systems are non-loadbearing, they Control joints may be required in the partition to relieve stresses
are able to provide resistance to levels of horizontal uniformly induced by expansion and contraction of the structure. They should
distributed loads. coincide with movement joints within the surrounding structure.

Refer to C02. S01. P26 – Robustness. Refer to Partitions introduction C04. S01. P10 – construction
detail 12.
Planning – key factors
Deflection heads
GypWall extreme comprises Gypframe 'C' Studs installed at 600mm
centres within Gypframe Deep Flange Floor & Ceiling Channels. Partition head deflection designs may be necessary to
The position of services and heavy fixtures should be accommodate deflections in the supporting floor. Deflection heads
pre-determined and their installation planned into the frame may also be required to the underside of roof structures subjected
Partitions

erection stage. to positive and negative pressures.

Fixing floor and ceiling channels To minimise the loss of acoustic performance:

Gypframe Deep Flange Floor & Ceiling Channels must be securely Refer to C02. S01. P10 – Building acoustics.
fixed with a row of fixings at 600mm maximum centres. For 94mm
C04

channels and above, two rows of staggered fixings are required, For deflection head design:
each row at 600mm centres and each fixing 25mm in from the
Refer to Partitions introduction C04. S01. P11 – construction
flange. If the floor is uneven, a 38mm thick timber sole plate equal
details 15-22.
to the width of the channel should be used.

Services
If the concrete or screeded floor is new, consideration should be
given to the installation of a damp-proof membrane between the Penetrations
floor surface and the channel or sole plate. Penetrations of fire-resistant or sound-insulating constructions
for services need careful consideration to ensure that the
Splicing performance of the element is not downgraded. Consideration also
needs to be given to the services themselves so they do not act as
To extend studs, overlap by 600mm (minimum). Fix together using
the mechanism of fire spread or sound transmission.
British Gypsum Wafer Head Drywall Screws or steel pop rivets (two
to each flange), or by using the Gyproc Stud Interlocking Tool twice Refer to C02. S01. P32 – Service installations.
to each flange.
Electrical
Refer to Partitions introduction C04. S01. P07 – construction
The installation of electrical services should be carried out in
detail 1.
accordance with BS 7671. The cut-outs in the studs can be used for
routing electrical and other small services (Partitions introduction
Partition to structural steelwork junctions
C04. S01. P07 – construction detail 2). Switch boxes and socket
When designing the layout of rooms requiring separation by sound outlets can be supported from Gypframe 99 FC 50 Fixing Channel
insulating walls abutting structural steelwork, consideration should fixed horizontally between studs, or a high performance socket box
be given to the potential loss of sound insulation performance detail used where higher acoustic performance is required.
through the steelwork.

Refer to C02. S01. P10 – Building acoustics. Where Gypframe AcouStuds are used, services are routed through
50mm x 28mm ‘H’ shaped push-outs, at the same centres as shown
Door openings in Partitions introduction C04. S01. P07 – construction detail 2a
for conventional cut-outs. Cables should be protected by conduit,
The designer should consider the thickness tolerances of the or other suitable precautions taken to prevent abrasion when they
partition types in relation to the proposed door frame detail. pass through the metal frame. Service cut-outs should be aligned to
To satisfy BS 5234 requirements for Heavy and Severe Duty allow easy installation of service. If studs require cutting, cut from
partitions, door framing should be specified as shown in Partitions the same end of each stud to ensure cut-out alignment.
introduction C04. S01. P14 – construction details 26. The door
manufacturer should also be consulted in relation to the door detail. Independent support

If a plastered finish is specified, the thickness of the door or glazing When designing for the installation of services such as fire
frame must allow for the thickness of the plaster finish. dampers and associated ductwork through a GypWall partition,
consideration should be given to the size and weight of the
Cavity barriers damper - this will determine whether it can be supported directly
from the partition or needs to be independently supported from
Minimum 12.5mm Gyproc plasterboard screw-fixed into the web the structure.
of perimeter channels or vertical studs will provide a satisfactory
closure to flame or smoke. Refer to Partitions introduction C04. S01. P17 – construction
details 28-31.
Refer to C06. S07. P02 – Cavity barriers.

C04. S04. P09 british-gypsum.com


GypWall extreme design (continued)

GypWall extreme
Fixtures Board finishing

Due to the inherent strength of Rigidur h, some fixtures can be For increased resistance to accidental damage, a skim coat of
made directly to the board – please see the Rigidur h for commercial ThistlePro DuraFinish plaster may be applied.
applications Product Data Sheet and the British Gypsum Site Book
Refer to the Rigidur h for commercial applications Product Data
for more information, available to download from
Sheet, available to download from british-gypsum.com
british-gypsum.com. Heavyweight fixtures (to BS 5234), such
as wash basins and wall cupboards, can be fixed using plywood
Tiling
secured with Gypframe Service Support Plates.
Tiles can be applied to the surface of lightweight partition systems.
Refer to C02. S01. P33 – Service installations.
Refer to C08. S04. P02 – Tiling
Access for maintenance
Construction details

Partitions
Gyproc Profilex Access Panels are available to provide access for
maintenance. Access panels must be fully compatible with drywall For standard GypWall construction details
construction and match the fire rating of the partition. Refer to Partitions introduction C04. S01. P07 – construction
details
Refer to profilex.co.uk for further information.

C04
Handy hint SpecSure®
— Rigidur h is available as a special order in All our systems are covered by SpecSure® when
sizes up to 2.5m x 6.0m, reducing the using genuine British Gypsum and Saint-Gobain
amount of tape and jointing required Isover products.
— The use of insulation within the partition
cavity to provide a higher acoustic
performance than may initially be
required, will help to future proof for
subsequent changes of room use
— Cut-outs in the Gypframe Studs can be
used to accommodate horizontal service
runs. Installers should be made aware of
this to avoid vertical misalignment of
cut-outs between adjacent studs

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S04. P10


GypWall extreme construction details
GypWall extreme

1 2

4 1

2
Partitions

2
C04

Head Base

3 4

1
1

Junction with masonry and stop end Corner

1 Rigidur h 5 Bulk fill with Gyproc jointing materials (where gap exceeds 5mm)
2 Gypframe ‘C’ Stud 6 Skirting
3 Gypframe Deep Flange Floor & Ceiling Channel 7 Internal blockwork
4 Gyproc Sealant 8 DriLyner basic wall lining system

C04. S04. P11 british-gypsum.com


GypWall extreme system components

GypWall extreme
Gypframe metal components ( Refer to C10. S02. P02 for details)

Gypframe ‘C’ Studs (70 S 60) Gypframe GFS1 Fixing Strap


Vertical stud providing acoustic and structural Used to support horizontal board joints and within
performances designed to receive fixing of board deflections heads.
to both sides.

Gypframe AcouStud (70 AS 50, 146 AS 50) Gypframe GFT1 Fixing T


Vertical stud providing enhanced acoustic and Used to support horizontal board joints.
structural performances designed to receive fixing
of board to both sides.

Partitions
Gypframe Deep Flange Floor & Ceiling Channels Gypframe GA5 Internal Fixing Angle
(72 DC 60, 148 DC 60) Steel angle providing framing stability and
Floor and ceiling channels with deep flanges for board support.

C04
retaining the Gypframe studs at floor and ceiling
junctions for partitions 4200mm to 8000mm high.
Also used around openings and in deflection heads
(maximum 30mm deflection).

Gypframe Extra Deep Flange Floor & Ceiling Gypframe GA6 Splayed Angle
Channels (72 EDC 80, 148 EDC 80) Steel angle providing framing stability and
Floor and ceiling channels with extra deep flanges board support.
for retaining the Gypframe studs at floor and ceiling
junctions for partitions over 8000mm high. Also used
around openings and in deflection heads (maximum
50mm deflection).

Gypframe 99 FC 50 Fixing Channel Gypframe Service Support Plate


A versatile metal fixing channel used to support For installation of 18mm plywood within
medium weight fixtures on walls. a partition cavity to support medium to
heavyweight fixtures.

Board products ( Refer to C10. S03. P02 for details)

Rigidur h Gyproc WallBoard1


Gypsum fibre board with additives for rigidity, Standard gypsum plasterboard, used as inner layer.
durability and mechanical strength.

Gyproc DuraLine1 Glasroc F firecase


Gypsum plasterboard with fire resistant additives Non-combustible glass-reinforced gypsum board.
and a high density core for enhanced sound Used to form deflection head.
insulation and impact resistance performance.

Gyproc SoundBloc 1 Gyproc CoreBoard


Gypsum plasterboard with a high density core for Gypsum plasterboard with fire and moisture
enhanced sound insulation performance. resistant additives. Used to form deflection head.

1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S04. P12


GypWall extreme system components (continued)
GypWall extreme

Fixing products ( Refer to C10. S04. P02 for details)

British Gypsum Drywall Screws Rigidur Screws


Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws
for fixing inner layer of board to metal framing less designed for fixing Rigidur h board to framing.
than 0.8mm thick. (Gypframe 'C' Studs and Gypframe AcouStuds less
than 0.8mm thick).

British Gypsum Collated Drywall Screws British Gypsum Jack-Point Screws


Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws
for fixing inner layer of board to metal framing less for fixing board to metal framing 0.8mm thick and
Partitions

than 0.8mm thick. greater (‘I’ stud 0.6mm thick and greater).

British Gypsum Wafer Head Drywall Screws British Gypsum Wafer Head Jack-Point Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws for
C04

for fixing metal to metal framing less than fixing metal to metal framing 0.8mm thick
0.8mm thick (‘I’ studs less than 0.6mm thick). (‘I’ studs 0.6mm thick and greater).

Plasterboard accessories ( Refer to C10. S05. P02 for details)

Gyproc Jointing Material Gyproc edge and angle beads


Jointing compounds, ready mixes and adhesives Protecting and enhancing board edges and corners
for reinforcement and finishing of board joints.
Primers and sealers for treatment of boards for
pre-decoration.

Gyproc Control Joint Gyproc Corner Tape


To accommodate structural movement of up A paper tape bonded to two corrosion resistant
to 7mm. steel strips.

Gyproc FireStrip Gyproc Joint Tape


A soft extruded linear intumescent gap sealer A paper tape designed for reinforcement of flat
to maintain fire resistance located directly to joints or internal angles.
the underside of the soffit when forming a
deflection head.

Gyproc Sealant Gyproc Habito Corners


Used to seal air paths for optimum sound A high strength, tapered co-polymer core offers
insulation. strong and uniform surface bonding for internal
and external angles in plasterboard constructions.

Gyproc AquaBead
An easy to apply, water, activated adhesive corner
bead, for reinforcing external 90°C angles in taped
and jointed plasterboard constructions.

C04. S04. P13 british-gypsum.com


GypWall extreme system components (continued)

GypWall extreme
Finishing products ( Refer to C10. S06. P02 for details)

Thistle MultiFinish ThistlePro DuraFinish


To provide a plaster skim finish on most common To provide a plaster skim finish and provide up to
backgrounds including undercoat plasters and 60% tougher resistance to accidental damage.
plasterboard. Can provide enhanced acoustic
performance.

Thistle BoardFinish ThistlePro PureFinish


To provide a plaster skim finish to To provide a plaster skim finish with
Gyproc plasterboards. ACTIVair technology. Used to finish most

Partitions
common backgrounds including undercoat plasters
and plasterboard. For more information refer to
C02. S01. P49.

C04
Thistle SprayFinish ThistlePro Magnetic
To provide a plaster skim finish by spray or hand To provide a plaster skim finish that provides an
application, ideal for medium to large projects. attraction to magnets used to finish a wide range
of backgrounds, including undercoat plasters and
plasterboard.

Thistle ProTape FT50 Plaster accessories


Self-adhesive 48mm wide glass fibre mesh tape. Designed for the reinforcement and finishing of
board joints before plaster skimming.

Thistle ProTape FT100


Self-adhesive 100mm wide glass fibre mesh tape.

Insulation products ( Refer to C10. S09. P02 for details)

Isover Acoustic Partition Roll (APR 1200)


Glass mineral wool for enhanced acoustic and
thermal performance.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S04. P14


GypWall extreme installation overview
GypWall extreme

This is intended to be a basic description of how the system is built.


For detailed installation guidance refer to the British Gypsum Site Book.
Partitions

Gypframe Deep Flange or Extra Deep Flange Gypframe Studs are suitably fixed to The perimeter of the partition is then sealed
Floor & Ceiling Channels are suitably fixed abutments. on both sides with Gyproc Sealant.
to the floor and soffit.
C04

Gypframe studs are then friction fitted into Door openings are constructed to the Heavy M&E services can be located within the
the Gypframe Deep Flange Floor & Ceiling and Severe Duty detail. partition cavity.
Channels at required centres.

Isover insulation can also be added to Gyproc DuraLine, Gyproc SoundBloc or Rigidur h boards are then fixed as the outer
the partition cavity for increased acoustic Gyproc WallBoard plasterboards may be layer to all Gypframe framing members
performance. installed as either an inner layer, or as part with Rigidur Screws.
of the GypWall extreme / robust hybrid system
with British Gypsum Drywall Screws. It is recommended that Rigidur H
boards are pre-drilled and countersunk
screw locations for improved ease of
installation. For further information, refer to
the British Gypsum Good Practice Guide.
Additional information
For full installation details, refer to the
British Gypsum Site Book, available to
download from british-gypsum.com

C04. S04. P15 british-gypsum.com


GypWall extreme
Partitions
C04

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S04. P16


GypWall quiet sf

GypWall quiet sf
Single frame acoustic separating wall system

All our systems are covered by SpecSure® when using


genuine British Gypsum and Saint-Gobain Isover products
Partitions
C04
GypWall quiet sf
GypWall quiet sf
GypWall quiet sf is a non-loadbearing partition,
60 120
which provides high levels of sound insulation mins

up to and exceeding regulatory requirements


for separating walls.
61 65
Rw dB
GypWall quiet sf offers high levels of acoustic
performance within a narrow footprint.

Partitions
This makes it the ideal solution for a wide
range of buildings where it is important System can be skim
finished with
ThistlePro PureFinish.
to provide occupants with a comfortable

C04
Refer to C02. S01. P49

acoustic environment, whilst at the same time


maximising available floor area, for example,
schools and hospitals. Refer to C01. S01. P07

Key benefits
— Very efficient use of floor space due to a high
level of acoustic performance being achieved
with a minimal partition width
— Reduced sound transmission is achieved
through the use of Gypframe RB1 Resilient Bar
to provide a high degree of isolation between
the Gypframe 'C' Studs and the high
performance Gyproc plasterboard lining
— Additional acoustic performance can be
achieved with the application of
Thistle MultiFinish plaster skim on selected
specifications

You may also be interested in...


Looking for an increase in acoustic performance? For example, if designing for a prestigious
development or to achieve credits towards a BREEAM framework.

GypWall quiet iwl


Provides greater levels of acoustic insulation, through the use of totally isolated twin
stud frameworks.
Refer to C04. S08. P02 – GypWall quiet iwl.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S05. P02


GypWall quiet sf performance
GypWall quiet sf

For details of when


to specify fire
70mm, 92mm and 146mm Gypframe ‘C’ Stud resistance using EN
Refer to C02. S01. P05
Table 1a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

Two layers of board each side of Gypframe ‘C’ Two layers of board each side of Gypframe ‘C’ Two layers of board each side of Gypframe ‘C’
Studs at 600mm centres with Gypframe RB1 Studs at 600mm centres with Gypframe RB1 Studs at 600mm centres with Gypframe RB1
Partitions

Resilient Bar at 600mm centres to one side. 50mm Resilient Bar at 600mm centres to both sides. Resilient Bar at 600mm centres to one side. 50mm
Isover Acoustic Partition Roll (APR 1200) 50mm Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table. in the cavity. Linings as in table.
C04

Detail Partition Board type1 Lining Stud Max. Sound insulation Duty Approx. System reference
thickness thickness size partition Rw (Rw + Ctr) dB5 rating weight
mm mm mm height2 kg/m²
mm Any3 Skim4 Any3 Skim4
finish only finish only

60 minutes fire resistance

1 137 Gyproc SoundBloc 2 x 12.5 70 4000 61 (53) - Severe 43 A316008 -

2 152 Gyproc SoundBloc 2 x 12.5 70 3200 62 (55) - Severe 43 A316012 -

1 159 Gyproc SoundBloc 2 x 12.5 92 5000 61 (53) - Severe 43 A316014 -

2 174 Gyproc SoundBloc 2 x 12.5 92 4000 63 (55) - Severe 43 A316015 -

1 213 Gyproc SoundBloc 2 x 12.5 146 6800 62 (56) - Severe 43 A316016 -

2 228 Gyproc SoundBloc 2 x 12.5 146 5700 64 (58) - Severe 43 A316018 -

90 minutes fire resistance

1 147 Gyproc SoundBloc 2 x 15 70 4200 62 (54) - Severe 51 A316009 -


Gyproc Plank + 1 x 19 +
3 150 70 3800 63 (54) - Severe 54 A316011 -
Gyproc SoundBloc 1 x 12.5
2 162 Gyproc SoundBloc 2 x 15 70 3200 65 (57) - Severe 51 A316013 -

1 223 Gyproc SoundBloc 2 x 15 146 5000 62 (57) 63 (57) Severe 51 A316017 A316017S

2 238 Gyproc SoundBloc 2 x 15 146 5000 65 (59) - Severe 51 A316019 -

120 minutes fire resistance

Gyproc FireLine + 1 x 15 +
1 147 70 4000 61 (53) 62 (53) Severe 53 Q606040 Q606040S
Gyproc DuraLine 1 x 15

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
For improved durability and impact resistance, the outer layer can be replaced with a layer of 15mm Gyproc DuraLine.
3
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
3
Sound insulation performance for partitions finished using jointing or plaster skim.
4
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
5
These British Gypsum Approved Systems are designed to achieve minimum DnT,w + Ctr 45dB, subject to Pre-Completion Testing
(Refer to Partitions introduction C04. S01. P04 – table 1)

For heights above 4200mm Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to deflection criteria).

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S05. P03 british-gypsum.com


GypWall quiet sf performance (continued)

GypWall quiet sf
For details of when
to specify fire
70mm, 92mm and 146mm Gypframe ‘C’ Stud resistance using BS
Refer to C02. S01. P05
Table 1b — Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2 3

Two layers of board each side of Gypframe ‘C’ Two layers of board each side of Gypframe ‘C’ Two layers of board each side of Gypframe ‘C’
Studs at 600mm centres with Gypframe RB1 Studsat 600mm centres with Gypframe RB1 Studs at 600mm centres with Gypframe RB1

Partitions
Resilient Bar at 600mm centres to one side. 50mm Resilient Bar at 600mm centres to both sides. Resilient Bar at 600mm centres to one side. 50mm
Isover Acoustic Partition Roll (APR 1200) 50mm Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Partition Roll (APR 1200)
in the cavity. Linings as in table. in the cavity. Linings as in table. in the cavity. Linings as in table.

C04
Detail Partition Board type1 Lining Stud Max. Sound insulation Duty Approx. System reference
thickness thickness size partition Rw (Rw + Ctr) dB5 rating weight
mm mm mm height2 kg/m²
mm Any3 Skim4 Any3 Skim4
finish only finish only

60 minutes fire resistance

1 137 Gyproc SoundBloc 2 x 12.5 70 4000 61 (53) - Severe 43 A316008 -

2 152 Gyproc SoundBloc 2 x 12.5 70 3200 62 (55) - Severe 43 A316012 -

1 159 Gyproc SoundBloc 2 x 12.5 92 5000 61 (53) - Severe 43 A316014 -

2 174 Gyproc SoundBloc 2 x 12.5 92 4000 63 (55) - Severe 43 A316015 -

1 213 Gyproc SoundBloc 2 x 12.5 146 6800 62 (56) - Severe 43 A316016 -

2 228 Gyproc SoundBloc 2 x 12.5 146 5700 64 (58) - Severe 43 A316018 -

90 minutes fire resistance

1 147 Gyproc SoundBloc 2 x 15 70 4200 62 (54) - Severe 51 A316009 -


Gyproc Plank + Gyproc 1 x 19 +
3 150 70 3800 61 (53) - Severe 49 A316010 -
WallBoard 1 x 12.5
Gyproc Plank + Gyproc 1 x 19 +
3 150 70 3800 63 (54) - Severe 54 A316011 -
SoundBloc 1 x 12.5
2 162 Gyproc SoundBloc 2 x 15 70 3200 65 (57) - Severe 51 A316013 -

1 223 Gyproc SoundBloc 2 x 15 146 6900 62 (57) 63 (57) Severe 51 A316017 A316017S

2 238 Gyproc SoundBloc 2 x 15 146 5700 65 (59) - Severe 51 A316019 -

120 minutes fire resistance

Gyproc FireLine + 1 x 15 +
1 147 70 4200 61 (53) 62 (53) Severe 53 Q606040 Q606040S
Gyproc DuraLine 1 x 15

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
For improved durability and impact resistance, the outer layer can be replaced with a layer of 15mm Gyproc DuraLine.
2
Based on a limiting deflection of L/240 at 200 Pa. For increased heights Gypframe 'I' Studs could be used (Refer to table 2 within this section)
3
Sound insulation performance for partitions finished using jointing or plaster skim.
4
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
5
These British Gypsum Approved Systems are designed to achieve minimum DnT,w + Ctr 45dB, subject to Pre-Completion Testing
(Refer to Partitions introduction C04. S01. P04 – table 1)

For heights above 4200mm Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to deflection criteria).

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S05. P04


GypWall quiet sf performance (continued)
GypWall quiet sf

70mm and 92mm Gypframe ‘I’ Stud


Table 2 – Increased heights using Gypframe 'I' Studs (mm)1

Studs at 600mm 2 x 12.5mm board, 2 x 15mm board, 19mm + 12.5mm board, Gypframe RB1 Resilient Bar
centres Gypframe RB1 Resilient Bar Gypframe RB1 Resilient Bar Gypframe RB1 Resilient Bar both sides
to one side to one side to one side

70 'I' 50 4400 4600 4200 3700

70 'I' 70 4800 5000 4700 4300

92 'I' 90 6300 6400 6100 5800

1
The above have not been subjected to acoustic tests and therefore any sound insulation performances are opinion only.

For heights between 4200mm and 8000mm Gypframe Deep Flange Floor & Ceiling Channel should be used.
Partitions
C04

C04. S05. P05 british-gypsum.com


GypWall quiet sf design

GypWall quiet sf
Building design Door openings

GypWall quiet sf comprises Gypframe 'C' Studs installed at Any openings will require very careful detailing to minimise the
600mm centres within Gypframe Floor & Ceiling Channels and loss of acoustic performance of the partition. Consult with an
Gypframe RB1 Resilient Bars horizontally fixed to one or both sides. Acoustic Consultant. Specialist heavy acoustic doorsets may require
additional support.
Planning – key factors
Refer to construction detail 8 within this section.
The position of services and heavy fixtures should be
pre-determined and their installation planned into the frame Framing surround for openings
erection stage. Timber sole plates should be considered where
Where services such as horizontal ducts, fire dampers and access
the floor is uneven. All penetrations will need to be adequately
panels are required to penetrate the wall, their position should be
fire-stopped.
pre-determined in order that a framed opening can be provided.

Partitions
The openings should be constructed using established metal stud
procedures.
Handy hint
Refer to Partitions introduction C04. S01. P16 – construction
details 28-31.
Be aware that if working to centre lines on a

C04
plan, GypWall quiet sf systems incorporating
Cavity barriers
Gypframe RB1 Resilient Bar to one side only
are not symmetrical. Stone mineral wool (by others) cut neatly to fit across the cavity
forms a suitable closure.

Fixing floor and ceiling channels Acoustic performance


Gypframe Floor & Ceiling Channels must be securely fixed with a The partition achieves high levels of sound insulation by virtue of
row of fixings at 600mm maximum centres. For 94mm channels the separation between the board and the stud framing afforded
and above, two rows of staggered fixings are required, each row at by the Gypframe RB1 Resilient Bars. It is important that, when
600mm centres and each fixing 25mm in from the flange. If the screw-fixing boards, the screws do not contact the stud framing and
floor is uneven, a 38mm thick timber sole plate equal to the width also that services, fixtures, etc, do not form a bridge between the
of the channel should be used. lining boards on each side of the partition.

If the concrete or screeded floor is new, consideration should be For optimum performance all air paths should be sealed.
given to the installation of a damp-proof membrane between the Gyproc Sealant should be applied to the perimeter of the inner layer
floor surface and the channel or sole plate. immediately prior to fitting the face layer board on the side(s) of the
partition where resilient bars are located.

Important information Deflection heads

Partition head deflection designs may be necessary to


For partition heights above 4200mm,
accommodate deflections in the supporting floor. Deflection heads
Gypframe Deep Flange Floor & Ceiling
may also be required to the underside of roof structures subjected
Channels should be used.
to positive and negative pressures.

The partitions can incorporate head deflection designs with


Splicing
only a slight reduction in sound insulation performance. Refer to
To extend studs, overlap by 600mm (minimum). Fix together using construction detail 3 within this section.
British Gypsum Wafer Head Drywall Screws or steel pop rivets (two
to each flange), or by using the Gyproc Stud Interlocking Tool twice To minimise the loss of acoustic performance:
to each flange.
Refer to C02. S01. P10 – Building acoustics.
Refer to Partitions introduction C04. S01. P07 – construction
detail 1 Services

Penetrations
Partition to structural steelwork junctions
Penetrations of fire-resistant or sound-insulating constructions
When designing the layout of rooms requiring separation by sound
for services need careful consideration to ensure that the
insulating walls abutting structural steelwork, consideration should
performance of the element is not downgraded. Consideration also
be given to the potential loss of sound insulation performance
needs to be given to the services themselves so they do not act as
through the steelwork.
the mechanism of fire spread or sound transmission.

If you require a wider partition to fully encompass structural steel, Refer to C02. S01. P32 – Service installations.
refer to GypWall quiet or GypWall quiet iwl.

Refer to C02. S01. P10 – Building acoustics.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S05. P06


GypWall quiet sf

GypWall quiet sf design (continued)

Electrical Fixtures
The installation of electrical services should be carried out in
Lightweight fixtures can be made directly to the partitions.
accordance with BS 7671. The cut-outs in the studs can be used
Medium weight fixtures can be made to Gypframe 99 FC 50 Fixing
for routing electrical and other small services (refer to Partitions
Channel. Heavyweight fixtures (to BS 5234), such as wash basins
introduction C04. S01. P07 – construction detail 2). Switch boxes
and wall cupboards, can be fixed using plywood secured with a
and socket outlets can be supported from Gypframe 99 FC 50 Fixing
Gypframe Service Support Plates. In all instances the
Channel fixed horizontally between studs, or a high performance
Gypframe Service Support Plates are fixed to the side without a
socket box detail used where higher acoustic performance is
Gypframe RB1 Resilient Bar.
required.

Medium and heavy weight fixtures can only be made when the
Where Gypframe AcouStuds are used, services are routed through
lining boards are fixed directly to the stud framing. The installation
50mm x 28mm ‘H’ shaped push-outs, at the same centres as shown
of fixings may downgrade the acoustic performance of the wall,
Partitions

in Partitions introduction C04. S01. P07 – construction detail 2a


refer to C04. S05. P06 – Acoustic performance.
for conventional cut-outs. Cables should be protected by conduit,
or other suitable precautions taken to prevent abrasion when they Refer to C02. S01. P33 – Service installations.
pass through the metal frame. Service cut-outs should be aligned to
allow easy installation of service. If studs require cutting, cut from For alternative solutions, where fixtures are required to both sides
C04

the same end of each stud to ensure cut-out alignment. of a partition, consider using GypWall quiet or GypWall quiet iwl.

Independent support Board finishing


When designing for the installation of services such as fire Refer to C08. S01. P02 – Finishes.
dampers and associated ductwork through a GypWall partition,
consideration should be given to the size and weight of the Tiling
damper - this will determine whether it can be supported directly
Tiles can be applied to the surface of lightweight partition systems.
from the partition or needs to be independently supported from the
structure. Refer to C08. S04. P02 – Tiling.
Refer to Partitions introduction C04. S01. P17 – construction
details 29-31.

SpecSure®
All our systems are covered by SpecSure® when
using genuine British Gypsum and Saint-Gobain
Isover products.

C04. S05. P07 british-gypsum.com


GypWall quiet sf construction details

GypWall quiet sf
1 2

5
6
6
2

Partitions
3

10

11

C04
15
1

3
Junction with masonry

4 3

17
2
14
12
6

15mm
13
15mm

9 20mm

8 16
4
7 1

6 2
3
5

Deflection head for 15mm downward movement and


Head and base 60 minutes fire resistance

1 Gyproc plasterboard 11 Blockwork


2 Gypframe ‘C’ Stud 12 Gyproc CoreBoard or Glasroc F firecase (width of Gypframe stud
3 Gypframe RB1 Resilient Bar and Gypframe RB1 Resilient Bar)
4 50mm Isover Acoustic Partition Roll (APR 1200) 13 Gypframe Steel Angle
5 Gypframe Floor & Ceiling Channel 14 Gyproc FireStrip
6 Gyproc Sealant 15 DriLyner basic wall lining system
7 Bulk fill with Gyproc jointing materials (where gap exceeds 5mm) 16 Gypframe GFS1 Fixing Strap
8 Timber packer (16 x 50mm) 17 Gypframe Deep Flange Floor & Ceiling Channel suitable fixed through
fire-stop to structure
9 Skirting
10 Vertical Gypframe RB1 Resilient Bar noggings

No fixings should be made through the boards into the flanges of the head channel. The arrow ( ) denotes the position of the uppermost board
fixing, which should be made into Gypframe GFS1 Fixing Strap. Continuous Gyproc FireStrip must be installed as shown to maintain fire performance.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S05. P08


GypWall quiet sf

GypWall quiet sf construction details (continued)

4 5

3
3

2 2
1
1
Partitions

5
4
C04

5 4

Corner - resilient bar to external corner Corner - resilient bar to internal corner

6 7

3 3

2 2
1 1
6 6

4 4

5 5

‘T’ junction (resilient bar on opposite side) ‘T’ junction (resilient bar on abutment side)

1 Gyproc plasterboard 4 50mm Isover Acoustic Partition Roll (APR 1200)


2 Gypframe ‘C’ Stud 5 Vertical Gypframe RB1 Resilient Bar nogging
3 Gypframe RB1 Resilient Bar 6 Gypframe GA5 Internal Fixing Angle

Guidance must be sought from the relevant approval authority e.g. Building Control to establish if a cavity barrier is required (Approved Document B)

C04. S05. P09 british-gypsum.com


GypWall quiet sf
GypWall quiet sf construction details (continued)

150mm

Partitions
4

C04
8

7
2
300mm

10

1200mm 1200mm

11

150mm

Door frame to satisfy BS 5234: Parts 1 and 2: 1992 - Heavy and Severe Duty (up to 60kg door)

1 Gyproc plasterboard 7 Gypframe RB1 Resilient Bar


2 Gypframe ‘C’ Stud 8 Gypframe RB1 Resilient Bar vertical nogging
3 Gypframe Folded Edge Standard Floor & Ceiling Channel 9 50mm Isover Acoustic Partition Roll (APR 1200)
4 Gypframe Folded Edge Standard Floor & Ceiling Channel cut 10 Gypframe Folded Edge Standard Floor & Ceiling Channel cut
and bent to form door head and extend up studs
5 Timber door frame and architrave 11 Suitable solvent based construction adhesive with instant grab (by others)
6 Gypframe ‘C’ Stud to maintain stud module

Advice should be sought from the door manufacturer prior to the construction of these details.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S05. P10


GypWall quiet sf system components
GypWall quiet sf

Gypframe metal components ( Refer to C10. S02. P02 for details)

Gypframe ‘C’ Studs (70 S 50, 92 S 50, 146 S 50) Gypframe 99 FC 50 Fixing Channel
Vertical stud providing acoustic and structural A versatile metal fixing channel used to support
performances designed to receive fixing of board medium weight fixtures on walls.
after installation of Gypframe RB1 Resilient Bars.

Gypframe Folded Edge Standard Floor & Ceiling Gypframe GFS1 Fixing Strap
Channels (72 FEC 50, 94 FEC 50, 148 FEC 50) Used to support horizontal board joints and within
Standard floor and ceiling channels for retaining the deflection head.
Gypframe studs at floor and ceiling junctions and
Partitions

around openings to heights not exceeding 4200mm.

Gypframe Deep Flange Floor & Ceiling Channels Gypframe GFT1 Fixing T
(72 DC 60, 94 DC 60, 148 DC 60) Used to support horizontal board joints.
C04

Floor and ceiling channels with deep flanges for


retaining the Gypframe studs at floor and ceiling
junctions for partitions 4200mm to 8000mm high.
Also used around openings and in deflection heads
(maximum 30mm deflection).

Gypframe Extra Deep Flange Floor & Ceiling Gypframe RB1 Resilient Bar
Channels (72 EDC 80, 94 EDC 70, 148 EDC 80) Acoustically engineered channel to separate board
Floor and ceiling channels with extra deep flanges fixing from the primary frame. Fixed horizontally to
for retaining the Gypframe studs at floor and ceiling face of studs.
junctions for partitions over 8000mm high. Also used
around openings and in deflection heads (maximum
50mm deflection).

Gypframe GA5 Internal Fixing Angle Gypframe Service Support Plate


Steel angle providing framing stability and For installation of 18mm plywood within
board support. a partition cavity to support medium to
heavyweight fixtures.

Gypframe GA6 Splayed Angle


Steel angle providing framing stability and
board support.

Board products ( Refer to C10. S03. P02 for details)

Gyproc SoundBloc1 Gyproc WallBoard1


Gypsum plasterboard with a high density core for Standard gypsum plasterboard.
enhanced sound insulation performance.

Gyproc Plank Gyproc DuraLine1


Standard gypsum plasterboard located as an Gypsum plasterboard with fire resistant additives
inner layer. and a high density core for enhanced sound
insulation and impact resistance performance.

1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

C04. S05. P11 british-gypsum.com


GypWall quiet sf
GypWall quiet sf system components (continued)

Board products ( Refer to C10. S03. P02 for details)

Gyproc FireLine1 Gyproc CoreBoard


Gypsum plasterboard with fire resistant additives. Gypsum plasterboard with fire and moisture
resistant additives. Used to form deflection head.

Glasroc F firecase
Non-combustible glass-reinforced gypsum board.
Used to form deflection head.

Partitions
1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

Fixing products ( Refer to C10. S04. P02 for details)

C04
British Gypsum Drywall Screws British Gypsum Jack-Point Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws
for fixing board to metal framing less than for fixing board to metal framing 0.8mm thick and
0.8mm thick ('I' studs less than 0.6mm thick). greater (‘I’ studs 0.6mm thick and greater).

British Gypsum Collated Drywall Screws British Gypsum Wafer Head Jack-Point Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws for
for fixing board to metal framing less than fixing metal to metal framing 0.8mm thick and
0.8mm thick ('I' studs less than 0.6mm thick). greater ('I' studs 0.6mm thick and greater).

British Gypsum Wafer Head Drywall Screws


Corrosion resistant self-tapping steel screws
for fixing metal to metal framing less than
0.8mm thick ('I' studs less than 0.6mm thick).

Plasterboard accessories ( Refer to C10. S05. P02 for details)

Gyproc Jointing Material Gyproc edge and angle beads


Jointing compounds, ready mixes and adhesives Protecting and enhancing board edges and corners.
for reinforcement and finishing of board joints.
Primers and sealers for treatment of boards for
pre-decoration.

Gyproc FireStrip Gyproc Sealant


A soft extruded linear intumescent gap sealer Used to seal air paths for optimum sound
to maintain fire resistance located directly to insulation.
the underside of the soffit when forming a
deflection head.

Gyproc Joint Tape


A paper tape designed for reinforcement of flat
joints or internal angles.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S05. P12


GypWall quiet sf

GypWall quiet sf system components (continued)

Finishing products ( Refer to C10. S06. P02 for details)

Thistle MultiFinish ThistlePro DuraFinish


To provide a plaster skim finish on most common To provide a plaster skim finish and provide up to
backgrounds including undercoat plasters and 60% tougher resistance to accidental damage.
plasterboard. Can provide enhanced acoustic
performance.

Thistle BoardFinish ThistlePro PureFinish


To provide a plaster skim finish to To provide a plaster skim finish with
Partitions

Gyproc plasterboards. ACTIVair technology. Used to finish most


common backgrounds including undercoat plasters
and plasterboard. For more information refer to
C02. S01. P49.
C04

Thistle SprayFinish ThistlePro Magnetic


To provide a plaster skim finish by spray or hand To provide a plaster skim finish that provides an
application, ideal for medium to large projects. attraction to magnets used to finish a wide range
of backgrounds, including undercoat plasters and
plasterboard.

Thistle ProTape FT50 Plaster accessories


Self-adhesive 48mm wide glass fibre mesh tape. Designed for the reinforcement and finishing of
board joints before plaster skimming.

Thistle ProTape FT100


Self-adhesive 100mm wide glass fibre mesh tape.

Insulation products ( Refer to C10. S09. P02 for details)

Isover Acoustic Partition Roll (APR 1200)


Glass mineral wool for enhanced acoustic and
thermal performance.

C04. S05. P13 british-gypsum.com


GypWall quiet sf installation overview

GypWall quiet sf
This is intended to be a basic description of how the system is built.
For detailed installation guidance refer to the British Gypsum Site Book.

Partitions
Gypframe Floor & Ceiling channels are Gypframe 'C' Studs are suitably fixed to The perimeter of the partition is then
suitably fixed to the floor and soffit. abutments and door openings. sealed with Gyproc Sealant except where
Gypframe RB1 Resilent Bars are to be
If you are using Gypframe RB1 Resilient Bars Ensure Gyproc CoreBoard to the deflection installed on that side. Where Gypframe RB1

C04
on one side of the partition only, the dimensions head takes into account the width of the
Resilient Bars are to be installed, the
will be offset by 16mm. This needs to be Gypframe RB1 Resilent Bars.
Gyproc Sealant is applied to the perimeter
considered when detailing to show locations of
partition layouts. of the first layer of board.

Gypframe 'C' Studs are fitted vertically to a Gypframe RB1 Resilient Bars are fixed Gypframe RB1 Resilient Bars are installed
friction-fit within the channel sections, to transverse to the stud framing. vertically to abutment and door studs to
form the framework. Studs are fitted to all Gypframe RB1 Resilient Bars are joined by accept perimeter fixings for the Gyproc
face the same way. nesting them together over a Gypframe plasterboard linings.
‘C’ Stud using British Gypsum Wafer Head
Drywall Screws. Gypframe RB1 Resilient
Bars are normally fixed with the base flange
on the top side, with the exception of the
uppermost bar, which is fixed base flange
down to provide board fixing at the head.

Isover Acoustic Partition Roll (APR 1200) Gyproc plasterboards are fixed with To maintain acoustic performance care
insulation is added to the partition cavity British Gypsum Drywall Screws to the must be taken to select the correct length
for optimal acoustic performance. Gypframe RB1 Resilient Bars with all joints screws to avoid them contacting or penetrating
the Gypframe 'C' Studs when fixing Gyproc
staggered. Where Gyproc Plank is required plasterboards to Gypframe RB1 Resilient Bar.
as an inner layer, it is fixed horizontally to
the Gypframe RB1 Resilient Bars at each
bar position.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S05. P14


GypWall staggered

GypWall staggered
Staggered stud acoustic partition system

All our systems are covered by SpecSure® when using


genuine British Gypsum and Saint-Gobain Isover products
Partitions
C04
GypWall staggered
GypWall staggered
GypWall staggered is a non-loadbearing stud
30 90
partition incorporating a single framework with mins

staggered studs. This provides very high levels


of sound insulation with minimal footprint.
It is suitable for a wide range of applications, 49 63
Rw dB
including student accommodation, hotels and
offices, where the optimal balance of acoustic

Partitions
performance and partition width are required.
System can be skim
finished with
ThistlePro PureFinish.
Key benefits

C04
Refer to C02. S01. P49

— Reduced sound transmission is achieved by


staggering alternate studs within a single
framework, which partially decouples the
Refer to C01. S01. P07
plasterboard linings on each side of the partition
— Acoustic performance, comparable to a twin
frame partition system, is achievable when
using the 92 / 148 combination, with the
footprint of a single frame solution
— Capable of meeting regulatory acoustic
requirements for separating walls in residential
conversion projects where space is at a premium
— Allows the inclusion of pattresses to each side
of the system without compromising acoustic
performance when using 92 / 148 combination

You may also be interested in...


Looking for an increase in acoustic performance? GypWall quiet and GypWall quiet iwl provide greater
levels of acoustic insulation through the use of twin stud frameworks. They can also be used to
accommodate structural steel columns.

Refer to C04. S07. P02 – GypWall quiet and C04. S08. P02 – GypWall quiet iwl

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S06. P02


GypWall staggered performance
GypWall staggered

For details of when


to specify fire
60 / 72 and 92 / 148 combinations resistance using EN
Refer to C02. S01. P05
Table 1a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3 4

60 / 72 combination 92 / 148 combination 60 / 72 combination 92 / 148 combination


Two rows of Gypframe 60 I 70 ‘I’ Studs Two rows of Gypframe 92 I 90 ‘I’ Studs Two rows of Gypframe 60 I 70 ‘I’ Studs Two rows of Gypframe 92 I 90 ‘I’ Studs
in Gypframe 72 FEC 50 Folded Edge in Gypframe 148 DC 60 Deep Flange in Gypframe 72 FEC 50 Folded Edge in Gypframe 148 DC 60 Deep Flange
Standard Floor & Ceiling Channel. Floor & Ceiling Channel. Standard Floor & Ceiling Channel. Floor & Ceiling Channel.
Partitions

Gypframe SC1 Spacer Clips and Gypframe SC2 Spacer Clips and Gypframe SC1 Spacer Clips and Gypframe SC2 Spacer Clips and
alternate studs staggered in the alternate studs staggered in the alternate studs staggered in the alternate studs staggered in the
channel at 300mm centres. Linings and channel at 300mm centres. Linings and channel at 300mm centres. Linings and channel at 300mm centres. Linings and
insulation as in table. insulation as in table. insulation as in table. insulation as in table.
C04

Detail Partition Board Lining Max. partition Sound insulation Duty Approx. System
thickness type thickness height2 Rw (Rw + Ctr ) dB rating weight reference
mm mm1 mm mm kg/m²
25mm3 50mm3 25mm3 Any Skim
any any skim finish4 only5
finish4 finish4 only5

30 minutes fire resistance

1 102 Gyproc SoundBloc 1 x 15 3300 49 52 - Heavy 28 A233001/021 -

2 178 Gyproc SoundBloc 1 x 15 5400 53 55 54 Heavy 28 A233006/026 A233006S

60 minutes fire resistance

3 122 Gyproc SoundBloc 2 x 12.5 3600 57 59 (48) - Severe 44 A233002/022 -

4 198 Gyproc SoundBloc 2 x 12.5 5700 61 (51) 62 (53) 6


- Severe 44 A233007/027 -

90 minutes fire resistance

3 132 Gyproc SoundBloc 2 x 15 3900 59 (49) 61 (53)6 - Severe 53 A233003/023 -

4 208 Gyproc SoundBloc 2 x 15 5000 62 (54) 6


63 (55) 6
63 (54) 6
Severe 53 A233008/028 A233008S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
For improved durability and impact resistance, the outer layer of Gyproc SoundBloc can be replaced with a layer of 15mm Gyproc DuraLine. On single layer
linings this will improve duty rating to Severe Duty.
2
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
3
Isover Acoustic Partition Roll (APR 1200) insulation.
4
Sound insulation performance for partitions finished using jointing or plaster skim.
5
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
6
These British Gypsum Approved Systems are designed to achieve minimum DnT,w + Ctr 45dB, subject to Pre-Completion Testing
(Refer to Partitions introduction C04. S01. P04 – table 1)

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked
with British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

C04. S06. P03 british-gypsum.com


GypWall staggered performance (continued)

GypWall staggered
For details of when
to specify fire
60 / 72 and 92 / 148 combinations resistance using BS
Refer to C02. S01. P05
Table 1b — Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2 3 4

60 / 72 combination 92 / 148 combination 60 / 72 combination 92 / 148 combination


Two rows of Gypframe 60 I 70 ‘I’ Studs Two rows of Gypframe 92 I 90 ‘I’ Studs Two rows of Gypframe 60 I 70 ‘I’ Studs Two rows of Gypframe 92 I 90 ‘I’ Studs
in Gypframe 72 FEC 50 Folded Edge in Gypframe 148 DC 60 Deep Flange in Gypframe 72 FEC 50 Folded Edge in Gypframe 148 DC 60 Deep Flange
Standard Floor & Ceiling Channel. Floor & Ceiling Channel. Standard Floor & Ceiling Channel. Floor & Ceiling Channel.

Partitions
Gypframe SC1 Spacer Clips and Gypframe SC2 Spacer Clips and Gypframe SC1 Spacer Clips and Gypframe SC2 Spacer Clips and
alternate studs staggered in the alternate studs staggered in the alternate studs staggered in the alternate studs staggered in the
channel at 300mm centres. Linings and channel at 300mm centres. Linings and channel at 300mm centres. Linings and channel at 300mm centres. Linings and
insulation as in table. insulation as in table. insulation as in table. insulation as in table.

C04
Detail Partition Board Lining Max. Sound insulation Duty Approx. System
thickness type thickness partition Rw (Rw + Ctr ) dB rating weight reference
mm mm1 mm height2 kg/m²
25mm3 50mm3 25mm3 Any Skim
mm
any any skim finish4 only5
finish4 finish4 only5

30 minutes fire resistance

1 102 Gyproc SoundBloc 1 x 15 3300 49 52 - Heavy 28 A233001/021 -

2 178 Gyproc SoundBloc 1 x 15 5400 53 55 54 Heavy 28 A233006/026 A233006S

60 minutes fire resistance

3 122 Gyproc SoundBloc 2 x 12.5 3600 57 59 (48) - Severe 44 A233002/022 -

4 198 Gyproc SoundBloc 2 x 12.5 5700 61 (51) 62 (53) 6


- Severe 44 A233007/027 -

90 minutes fire resistance

3 132 Gyproc SoundBloc 2 x 15 3900 59 (49) 61 (53)6 - Severe 53 A233003/023 -

4 208 Gyproc SoundBloc 2 x 15 5800 62 (54) 6


63 (55) 6
63 (54) 6
Severe 53 A233008/028 A233008S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
For improved durability and impact resistance, the outer layer of Gyproc SoundBloc can be replaced with a layer of 15mm Gyproc DuraLine. On single layer
linings this will improve duty rating to Severe Duty.
2
Based on a limiting deflection of L/240 at 200 Pa.
3
Isover Acoustic Partition Roll (APR 1200) insulation.
4
Sound insulation performance for partitions finished using jointing or plaster skim.
5
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
6
These British Gypsum Approved Systems are designed to achieve minimum DnT,w + Ctr 45dB, subject to Pre-Completion Testing
(Refer to Partitions introduction C04. S01. P04 – table 1)

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked
with British Gypsum.

For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head
(subject to deflection criteria).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S06. P04


GypWall staggered design
GypWall staggered

Building design

GypWall staggered comprises two rows of Gypframe 'I' Studs at


600mm centres (offset 300mm) installed within Gypframe Floor
Important information
& Ceiling Channels and held in position with Gypframe SC1 or
For partition heights above 4200mm,
Gypframe SC2 Spacer Clips. Gypframe SC1 Spacer Clips are used
Gypframe Deep Flange Floor & Ceiling
in conjunction with 60 / 72 combination, whereas Gypframe SC2
Channels should be used.
Spacer Clips are used conjunction with 92 / 148 combination.

Planning – key factors


Framing surround for openings
The position of services and heavy fixtures should be
Where services such as horizontal ducts, fire dampers and access
pre-determined and their installation planned into the frame
panels are required to penetrate the wall, their position should be
erection stage.
Partitions

pre-determined in order that a framed opening can be provided.


The openings should be constructed using established metal stud
Fixing floor and ceiling channels
procedures.
Gypframe Floor & Ceiling Channels must be securely fixed with a
row of fixings at 600mm maximum centres. For 148mm channels, Refer to Partitions introduction C04. S01. P16 - construction
C04

details 28-31.
two rows of staggered fixings are required, each row at 600mm
centres and each fixing 25mm in from the flange. If the floor is
Cavity barriers
uneven, a 38mm thick timber sole plate equal to the width of the
channel should be used. Stone mineral wool (by others) cut neatly to fit across the cavity
forms a suitable closure.
If the concrete or screeded floor is new, consideration should be
given to the installation of a damp-proof membrane between the Acoustic performance
floor surface and the channel or sole plate.
The partition achieves high levels of sound insulation by virtue of
the separation between the two rows of studs. It is important that
Splicing
this isolation is maintained, and that services, fixtures, etc, do not
To extend studs, overlap by 600mm (minimum). Fix together using form a bridge between the two linings.
British Gypsum Wafer Head Jack-Point Screws or steel pop rivets
Refer to C02. S01. P10 – Building acoustics.
(two to each flange), or by using the Gyproc Stud Interlocking Tool
twice to each flange.
Deflection heads
Refer to Partitions introduction C04. S01. P07 – construction
Performance details apply to fixed head constructions. Partition
detail 1.
head deflection designs may be necessary to accommodate
deflections in the supporting floor. Deflection heads may also be
Partition to structural steelwork junctions
required to the underside of roof structures subjected to positive
When designing the layout of rooms requiring separation by sound and negative pressures.
insulating walls abutting structural steelwork, consideration should
be given to the potential loss of sound insulation performance The partitions can incorporate head deflection designs to optimise
through the steelwork. sound insulation performance.

Refer to C02. S01. P10 – Building acoustics. Refer construction details 2 and 3.

Door openings Services

Any openings will require careful detailing if the acoustic Penetrations


performance of the partition is to be maintained. Specialist heavy Penetrations of fire-resistant or sound-insulating constructions
acoustic doorsets may require additional support. for services need careful consideration to ensure that the
performance of the element is not downgraded. Consideration also
The designer should consider thickness tolerances of the partition needs to be given to the services themselves so they do not act as
types in relation to the proposed door frame detail. Standard door the mechanism of fire spread or sound transmission.
frame detailing to satisfy BS 5234 requirements for Heavy and
Refer to C02. S01. P32 – Service installations.
Severe Duty Ratings is shown in Partitions introduction
C04. S01. P14 – construction detail 26. Additional provision is
Electrical
required to support heavy doorsets. The door manufacturer should
The installation of electrical services should be carried out in
also be consulted in relation to door details.
accordance with BS 7671. The cut-outs in the studs can be used for
routing electrical and other small services.

Refer to Partitions introduction C04. S01. P07 – construction


detail 2.

C04. S06. P05 british-gypsum.com


GypWall staggered design (continued)

GypWall staggered
Switch boxes and socket outlets can be supported from Gypframe
99 FC 50 Fixing Channel fixed horizontally between studs, or a
high performance socket box detail used where higher acoustic
performance is required.

Cables should be protected by conduit, or other suitable precautions


taken to prevent abrasion when they pass through the metal frame.
Service cut-outs should be aligned to allow easy installation of
service. If studs require cutting, cut from the same end of each stud
to ensure cut-out alignment.

Refer to C02. S01. P32 – Service installations.

Partitions
Independent support

When designing for the installation of services such as fire


dampers and associated ductwork through a GypWall partition,
consideration should be given to the size and weight of the

C04
damper - this will determine whether it can be supported directly
from the partition or needs to be independently supported from
the structure.

Refer to Partitions introduction C04. S01. P17 – construction


details 29-31.

Fixtures

Lightweight fixtures can be made directly to the partitions. Medium


weight fixtures can be made to Gypframe 99 FC 50 Fixing Channel.
Heavyweight fixtures (to BS 5234), such as wash basins and wall
cupboards, can be fixed using plywood secured with Gypframe
Service Support Plates (suitable for 92/148 framing combination
only).

Refer to C02. S01. P33 – Service installations

Board finishing
Refer to C08. S01. P02 – Finishes.

Tiling

Tiles can be applied to the surface of lightweight partition systems.

Refer to C08. S04. P02 – Tiling

SpecSure®
All our systems are covered by SpecSure® when
using genuine British Gypsum and Saint-Gobain
Isover products.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S06. P06


GypWall staggered construction details
GypWall staggered

1 2

6 9

3 10

6
5
15mm

15mm 12
1
13
4
20mm 3

11
Partitions

2
2
C04

Deflection head for 15mm downward movement and


60 minutes fire resistance
8

5 3
3
9
7
6 15

Head and base 6

25mm
4
13

25mm 14

30mm 11
2
4

Deflection head for ± 25mm movement and


Clip attachment 60 minutes fire resistance

1 Gyproc SoundBloc 9 Gyproc FireStrip


2 Gypframe ‘I’ Stud 10 Gyproc CoreBoard or Glasroc F firecase
3 Gypframe Spacer Clip 11 Gypframe GFS1 Fixing Strap
4 Isover Acoustic Partition Roll (APR 1200) 12 Gypframe Deep Flange Floor & Ceiling Channel suitably fixed through
fire-stop to structure
5 Gypframe Floor & Ceiling Channel
13 Gypframe Steel Angle
6 Gyproc Sealant
14 Gypframe Extra Deep Flange Floor & Ceiling Channel fixed to
7 Bulk fill with Gyproc jointing materials (where gap exceeds 5mm)
timber head plate
8 Skirting
15 Timber head plate suitably fixed to structure

No fixings should be made through the boards into the flanges of the head channel. The arrow ( ) denotes the uppermost board fixing, which should
be made into Gypframe GFS1 Fixing Strap. Continuous Gyproc FireStrip must be installed as shown in order to maintain fire performance. Gypframe Steel Angle
or approved decorative trim (by others) should be fixed to the soffit either side of the partition as shown to maintain the acoustic performance. Where ±
deflection is a requirement, Gypframe SC1 or SC2 Spacer Clips must be pre-fixed to the ‘I‘ studs to avoid the risk of disengagement once deflection is taken up.

C04. S06. P07 british-gypsum.com


GypWall staggered construction details (continued)

GypWall staggered
5 6

3
7
2

1
9
5
5

4
4

Partitions
1

C04
Junction with masonry Corner

7 8

2
2

1
5

1
6
3

‘T’ junction Intermediate studs (60 / 72 combination)

2
3

Intermediate studs (92 / 148 combination)

1 Gyproc SoundBloc 6 Gypframe GA5 Internal Fixing Angle


2 Gypframe ‘I’ Stud 7 Blockwork
3 Gypframe Spacer Clip 8 DriLyner basic wall lining system
4 Gypframe ‘C’ Stud 9 Gyproc Sealant
5 Isover Acoustic Partition Roll (APR 1200)

Guidance must be sought from the relevant approval authority e.g. Building Control to establish if a cavity barrier is required (Approved Document B)

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S06. P08


GypWall staggered system components
GypWall staggered

Gypframe metal components ( Refer to C10. S02. P02 for details)

Gypframe ‘I’ Studs (60 I 70, 92 I 90) Gypframe SC1 Spacer Clip
Enhanced strength stud that allows for partition Clip to aid positioning and securing of
height, without increasing partition width designed Gypframe 60 I 70 ‘I’ Studs.
to receive fixing of board to one side only.

Gypframe ‘C’ Studs (70 S 50, 146 S 50) Gypframe SC2 Spacer Clip
Vertical stud providing acoustic and structural Clip to aid positioning and securing of
performances designed to receive fixing of board. Gypframe 92 I 90 ‘I’ Studs.
Partitions

Used at abutments and openings.

Gypframe Folded Edge Standard Floor & Ceiling Gypframe 99 FC 50 Fixing Channel
Channels (72 FEC 50, 148 FEC 50) A versatile metal fixing channel used to support
C04

Standard floor and ceiling channels for retaining the medium weight fixtures on walls.
Gypframe studs at floor and ceiling junctions and
around openings to heights not exceeding 4200mm,
whilst also containing Gypframe Spacer Clips.

Gypframe Deep Flange Floor & Ceiling Channels Gypframe GFS1 Fixing Strap
(72 DC 60, 148 DC 60) Used to support horizontal board joints, and within
Floor and ceiling channels with deep flanges for deflection heads.
retaining the Gypframe studs at floor and ceiling
junctions for partitions 4200mm to 8000mm high.
Also used around openings and in deflection heads Gypframe GFT1 Fixing T
(maximum 30mm deflection), whilst also containing Used to support horizontal board joints.
Gypframe Spacer Clips.

Gypframe Extra Deep Flange Floor & Ceiling Gypframe GA5 Internal Fixing Angle
Channels (72 EDC 80, 148 EDC 80) Steel angle providing framing stability and
Floor and ceiling channels with extra deep flanges board support.
for retaining the Gypframe studs at floor and ceiling
junctions for partitions over 8000mm high. Also used
around openings and in deflection heads (maximum Gypframe GA6 Splayed Angle
50mm deflection), whilst also containing Gypframe Steel angle providing framing stability and
Spacer Clips. board support.

Gypframe Service Support Plate


For installation of 18mm plywood within a partition
cavity to support medium to heavyweight fixtures
with 92 / 148 combination.

C04. S06. P09 british-gypsum.com


GypWall staggered system components (continued)

GypWall staggered
Board products ( Refer to C10. S03. P02 for details)

Gyproc SoundBloc1 Glasroc F firecase


Gypsum plasterboard with a high density core for Non-combustible glass-reinforced gypsum board.
enhanced sound insulation performance. Used to form deflection head.

Gyproc DuraLine1 Gyproc CoreBoard


Gypsum plasterboard with fire resistant additives Gypsum plasterboard with fire and moisture
and a high density core for enhanced sound resistant additives. Used to form deflection head.
insulation and impact resistance performance.

Partitions
1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

C04
Fixing products ( Refer to C10. S04. P02 for details)

British Gypsum Jack-Point Screws British Gypsum Wafer Head Jack-Point Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws for
for fixing board to metal framing 0.8mm thick and fixing metal to metal framing 0.8mm thick and
greater (‘I’ studs 0.6mm thick and greater). greater (‘I’ studs 0.6mm thick and greater).

Plasterboard accessories ( Refer to C10. S05. P02 for details)

Gyproc Jointing Material Gyproc edge and angle beads


Jointing compounds, ready mixes and adhesives Protecting and enhancing board edges and corners
for reinforcement and finishing of board joints.
Primers and sealers for treatment of boards for
pre-decoration.

Gyproc Joint Tape Gyproc Sealant


A paper tape designed for reinforcement of flat Used to seal air paths for optimum sound
joints or internal angles. insulation.

Gyproc FireStrip
A soft extruded linear intumescent gap sealer
to maintain fire resistance located directly to
the underside of the soffit when forming a
deflection head.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S06. P10


GypWall staggered system components (continued)
GypWall staggered

Finishing products ( Refer to C10. S06. P02 for details)

Thistle MultiFinish ThistlePro DuraFinish


To provide a plaster skim finish on most common To provide a plaster skim finish and provide up to
backgrounds including undercoat plasters and 60% tougher resistance to accidental damage.
plasterboard. Can provide enhanced acoustic
performance.

Thistle BoardFinish ThistlePro PureFinish


To provide a plaster skim finish to To provide a plaster skim finish with
Gyproc plasterboards. ACTIVair technology. Used to finish most
Partitions

common backgrounds including undercoat plasters


and plasterboard. For more information refer to
C02. S01. P49.
C04

Thistle SprayFinish ThistlePro Magnetic


To provide a plaster skim finish by spray or hand To provide a plaster skim finish that provides an
application, ideal for medium to large projects. attraction to magnets used to finish a wide range
of backgrounds, including undercoat plasters and
plasterboard.

Thistle ProTape FT50 Plaster accessories


Self-adhesive 48mm wide glass fibre mesh tape. Designed for the reinforcement and finishing of
board joints before plaster skimming.

Thistle ProTape FT100


Self-adhesive 100mm wide glass fibre mesh tape.

Insulation products ( Refer to C10. S09. P02 for details)

Isover Acoustic Partition Roll (APR 1200)


Glass mineral wool for enhanced acoustic and
thermal performance.

C04. S06. P11 british-gypsum.com


GypWall staggered installation overview

GypWall staggered
This is intended to be a basic description of how the system is built.
For detailed installation guidance refer to the British Gypsum Site Book.

Partitions
Gypframe Floor & Ceiling channels are Gypframe 'C' Studs are suitably fixed at The perimeter of the partition is then sealed
suitably fixed to the floor and soffit. abutments and door openings. on both sides with Gyproc Sealant.

C04
Gypframe SC1 or SC2 Spacer Clips are The studs are then friction fitted into Door openings are constructed to the Heavy
inserted to the top and bottom of the the Gypframe Channels, alternating the and Severe Duty rating door detail.
Gypframe 60 I 70 or 92 I 90 'I' Studs direction of the clip to create a staggered
respectively. stud framework.

M&E services can be located within the Isover Acoustic Partition Roll (APR 1200) is Gyproc SoundBloc plasterboards are then
partition cavity. Care should be taken to added to the partition cavity. screw fixed to alternate Gypframe ‘I’ Studs
prevent bridging, for example socket boxes and other framing members with
making contact with the opposing studs. British Gypsum Jack-Point Screws.

Additional information
For full installation details, refer to the
British Gypsum Site Book, available to
download from british-gypsum.com

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S06. P12


GypWall quiet

GypWall quiet
Twin frame high performance acoustic wall system

All our systems are covered by SpecSure® when using


genuine British Gypsum and Saint-Gobain Isover products
Partitions
C04
GypWall quiet
GypWall quiet
GypWall quiet is a lightweight, non-loadbearing,
60 120
twin framed acoustic separating wall, often used mins

in developments such as apartments, hotels,


hospitals and schools where a high level of
acoustic performance is required to either meet 60 64
RwdB
or exceed Building Regulations.

Partitions
Key benefits
— GypWall quiet can provide up to an estimated System can be skim
finished with
90 minutes fire protection to structural steel ThistlePro PureFinish.

C04
Refer to C02. S01. P49
enclosed within its cavity, whilst maintaining
the room-to-room acoustic performance
— Twin-frame design allows services and
structural steel to easily be accommodated Refer to C01. S01. P07

within the partition


— Reduced sound transmission is achieved by a
high degree of isolation between the two
frameworks and the use of high performance
Gyproc plasterboard linings
— Additional acoustic performance can be
achieved with the application of
Thistle MultiFinish plaster skim

You may also be interested in...


GypWall quiet iwl
Looking for an increase in acoustic performance? For example, if designing for a prestigious
development or to achieve credits towards a BREEAM framework.

GypWall quiet iwl provides greater levels of acoustic insulation, through the use of a totally isolated
twin stud frameworks.
Refer to C04. S08. P02 – GypWall quiet iwl

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S07. P02


GypWall quiet performance
GypWall quiet

For details of when


to specify fire
48mm Gypframe 'C' Studs with cross braces resistance using EN
Refer to C02. S01. P05
Table 1a — Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

Two Gypframe 48 S 50 ‘C’ Stud frameworks braced at Two Gypframe 48 S 50 ‘C’ Stud frameworks braced Two Gypframe 48 S 50 ‘C’ Stud frameworks braced at max.
Partitions

max. 1200mm centres. Studs at 600mm centres. at max. 1200mm centres. Studs at 600mm centres. 1200mm centres. Studs at 600mm centres.
Isover Acoustic Partition Roll (APR 1200) in the cavity Isover Acoustic Slab in the cavity (cavity width 190mm). Isover Acoustic Partition Roll (APR 1200) in the cavity
(cavity width 137mm). Linings and insulation as in table. Linings and insulation as in table. (cavity width 237mm). Linings and insulation as in table.
C04

Detail Partition Board type Lining Max. Insulation Sound insulation Duty Approx. System reference
thickness mm thickness partition thickness Rw (Rw + Ctr ) dB rating weight
mm mm height1 mm kg/m²
mm Any2 Skim3 Any2 Skim3
finish only finish only

60 minutes fire resistance

Gyproc Plank + 1 x 19 +
1 200 6200 25 61 (47) - Severe 55 A216001 -
Gyproc SoundBloc 1 x 12.5

1 200 Gyproc SoundBloc 2 x 15 6200 50 62 (56)4 63 (56)4 Severe 55 A216009 A216009S

2 250 Gyproc SoundBloc 2 x 15 6200 75 63 (57)4 64 (57)4 Severe 55 A216011 A216011S


Gyproc Plank + 1 x 19 +
3 300 6200 25 62 (52)4 - Severe 55 A216002 -
Gyproc SoundBloc 1 x 12.5
3 300 Gyproc SoundBloc 2 x 15 6200 25 63 (57)4 64 (57)4 Severe 55 A216008 A216008S

90 minutes fire resistance

Gyproc Plank + 1 x 19 +
1 200 5000 25 61 (47) - Severe 55 A216001 -
Gyproc SoundBloc 1 x 12.5

2 250 Gyproc SoundBloc 2 x 15 5000 75 63 (57)4 64 (57)4 Severe 55 A216011 A216011S

Gyproc Plank + 1 x 19 +
3 300 5000 25 62 (52)4 - Severe 55 A216002 -
Gyproc SoundBloc 1 x 12.5

3 300 Gyproc SoundBloc 2 x 15 5000 100 64 (58)4 - Severe 55 A216012 -

120 minutes fire resistance

1 200 Gyproc FireLine 2 x 15 7500 50 60 (53)4 61 (53)4 Severe 52 A216010 A216010S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.
2
Sound insulation performance for partitions finished using jointing or plaster skim.
3
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
4
These British Gypsum Approved Systems are designed to achieve minimum DnT,w + Ctr 45dB, subject to Pre-Completion Testing
(Refer to Partitions introduction C04. S01. P04 – table 1).

For heights above 4200mm Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to deflection criteria).

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S07. P03 british-gypsum.com


GypWall quiet performance (continued)

GypWall quiet
For details of when
to specify fire
48mm Gypframe 'C' Studs with cross braces resistance using BS
Refer to C02. S01. P05
Table 1b — Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2 3

Two Gypframe 48 S 50 ‘C’ Stud frameworks braced at Two Gypframe 48 S 50 ‘C’ Stud frameworks braced Two Gypframe 48 S 50 ‘C’ Stud frameworks braced at

Partitions
max. 1200mm centres. Studs at 600mm centres. at max. 1200mm centres. Studs at 600mm centres. max. 1200mm centres. Studs at 600mm centres.
Isover Acoustic Partition Roll (APR 1200) in the cavity Isover Acoustic Slab in the cavity (cavity width 190mm). Isover Acoustic Partition Roll (APR 1200) in the cavity
(cavity width 137mm). Linings and insulation as in table. Linings and insulation as in table. (cavity width 237mm). Linings and insulation as in table.

Detail Partition Board type Lining Max. Insulation Sound insulation Duty Approx. System reference

C04
thickness mm thickness partition thickness Rw (Rw + Ctr ) dB rating weight
mm mm height2 mm kg/m²
mm Any3 Skim4 Any3 Skim4
finish only finish only

90 minutes fire resistance

Gyproc Plank + Gyproc 1 x 19 +


1 200 6200 25 61 (47) - Severe 55 A216001 -
SoundBloc 1 x 12.5
1 200 Gyproc SoundBloc1 2 x 15 7500 50 62 (56)5 63 (56)5 Severe 55 A216009 A216009S

2 250 Gyproc SoundBloc 1


2 x 15 7500 75 63 (57) 5
64 (57) 5
Severe 55 A216011 A216011S
Gyproc Plank + Gyproc 1 x 19 +
3 300 6200 25 62 (52)5 - Severe 55 A216002 -
SoundBloc 1 x 12.5
3 300 Gyproc SoundBloc1 2 x 15 7500 25 63 (57)5 64 (57)5 Severe 55 A216008 A216008S

120 minutes fire resistance

1 200 Gyproc FireLine 2 x 15 7500 50 60 (53)5 61 (53)4 Severe 52 A216010 A216010S

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
To achieve an estimated 120 minutes fire resistance, substitute 2 x 15mm Gyproc SoundBloc for 2 x 15mm Gyproc DuraLine.
2
Based on limiting deflection of L/240 at 200 Pa.
3
Sound insulation performance for partitions finished using jointing or plaster skim.
4
Sound insulation performance for partitions finished with a 2mm skim finish of Thistle MultiFinish.
5
These British Gypsum Approved Systems are designed to achieve minimum DnT,w + Ctr 45dB, subject to Pre-Completion Testing
(Refer to Partitions introduction C04. S01. P04 – table 1).

For heights above 4200mm Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to deflection criteria).

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S07. P04


GypWall quiet performance (continued)
GypWall quiet

For details of when


to specify fire
resistance using EN / BS
Refer to C02. S01. P05
Table 2 — Solutions based on BS EN 1364-1 and BS 476: Part 21: 1987 1

Board Lining Fire Section factor3


type2 thickness resistance A/V (Hp/A)
mm min m-1

Gyproc SoundBloc 2 x 12.5 30 Up to 300

Gyproc SoundBloc 2 x 15 60 Up to 300

Gyproc Plank + Gyproc SoundBloc 1 x 19 + 1 x 12.5 60 Up to 300


Partitions

Gyproc FireLine or Gyproc DuraLine 2 x 15 90 Up to 300

1
Estimated fire protection to structural steelwork within this partition cavity. Based on metal stud thermocouple data.
2
For improved durability and impact resistance, the outer layer of Gyproc FireLine or Gyproc SoundBloc can be replaced with a layer of 15mm Gyproc DuraLine.
3
Based on four-sided exposure, with no vertical joints aligning with the column, and boards not fixed to the column to maintain air space (10mm for BS or
C04

50mm for EN).

C04. S07. P05 british-gypsum.com


GypWall quiet design

GypWall quiet
Building design Services

GypWall quiet comprises twin row Gypframe 'C' Studs at 600mm Penetrations
centres within twin row Gypframe Floor & Ceiling Channels. For Penetrations of fire-resistant or sound-insulating constructions
heights up to 2400mm each pair of studs must be cross braced at for services need careful consideration to ensure that the
mid-height. Where multiple braces are required the braces must be performance of the element is not downgraded. Consideration also
located at 1200mm vertical centres staggered by 600mm. needs to be given to the services themselves so they do not act as
the mechanism of fire spread or sound transmission.
Planning — key factors
Refer to C02. S01. P32 – Service installations.
The position of services and heavy fixtures should be
pre-determined and their installation planned into the frame Electrical
erection stage. All penetrations will need to be adequately stopped The installation of electrical services should be carried out in
for fire and acoustics. accordance with BS 7671. The cut-outs in the studs can be used for

Partitions
routing electrical and other small services (Partitions introduction
Fixing floor and ceiling channels C04. S01. P07 – construction detail 2). Switch boxes and socket
Gypframe Floor & Ceiling Channels must be securely fixed with a outlets can be supported from Gypframe 99 FC 50 Fixing Channel
row of fixings at 600mm maximum centres. If the floor is uneven, fixed horizontally between studs, or a high performance socket box
detail used where higher acoustic performance is required.

C04
a 38mm thick timber sole plate equal to the width of the channel
should be used.
Independent support
If the concrete or screeded floor is new, consideration should be When designing for the installation of services such as fire
given to the installation of a damp-proof membrane between the dampers and associated ductwork through a GypWall partition,
floor surface and the channel or sole plate. consideration should be given to the size and weight of the
damper - this will determine whether it can be supported directly
Splicing from the partition or needs to be independently supported from
the structure.
To extend studs, overlap by 600mm (minimum). Fix together using
British Gypsum Wafer Head Drywall Screws or steel pop rivets (two Refer to Partitions introduction C04. S01. P17 – construction
to each flange), or by using the Gyproc Stud Interlocking Tool twice details 29-31.
to each flange.
Fixtures
Refer to Partitions introduction C04. S01. P07 – construction
detail 1. Lightweight fixtures can be made directly to the partitions. Medium
weight fixtures can be made to Gypframe 99 FC 50 Fixing Channel.
Partition to structural steelwork junctions Heavyweight fixtures (to BS 5234), such as wash basins and wall
cupboards, can be fixed using plywood secured with Gypframe
When designing the layout of rooms requiring separation by sound
Service Support Plates.
insulating walls abutting structural steelwork, consideration should
be given to the potential loss of sound insulation performance Refer to C02. S01. P33 – Service installations.
through the steelwork.
Board finishing
Refer to C02. S01. P10 – Building acoustics.
Refer to C08. S01. P02 – Finishes.
Door openings
Tiling
Any openings will require careful detailing if the acoustic
performance is to be maintained. Specialist heavy acoustic door sets Tiles can be applied to the surface of lightweight partition systems.
may require additional support. Refer to C08. S04. P02 – Tiling

Cavity barriers

Stone mineral wool cut neatly to fit across the cavity forms a
suitable closure. SpecSure®
Deflection heads All our systems are covered by SpecSure® when
Partition head deflection designs may be necessary to using genuine British Gypsum and Saint-Gobain
accommodate deflections in the supporting floor. Isover products.
Deflection heads may also be required to the underside of roof
structures subjected to positive and negative pressures.
Special detailing to minimise the loss of acoustic performance:

Refer to C02. S01. P10 – Building acoustics.

For deflection head design refer to construction detail 2 within


this section.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S07. P06


GypWall quiet construction details
GypWall quiet

1 2

6
10
11
4 6
15mm
15mm
1 13
20mm

12
Partitions

5 9

2 5
C04

3 Deflection head for 15mm downward movement and


60 minutes fire resistance

6
4

Head and base

1 Gyproc plasterboard 7 Bulk fill with Gyproc jointing materials (where gap exceeds 5mm)
2 Gypframe ‘C’ Stud 8 Skirting
3 Gypframe 99 FC 50 Fixing Channel (at 1200mm vertical centres staggered 9 Gypframe Deep Flange Floor & Ceiling Channel suitable fixed through
fire-stop to structure
by 600mm centres of multiple braces)
10 Gyproc FireStrip
4 Gypframe Folded Edge Standard Floor & Ceiling Channel
11 Gyproc CoreBoard or Glasroc F firecase
5 Isover insulation suitably supported at head
12 Gypframe GFS1 Fixing Strap
6 Gyproc Sealant
13 Gypframe Steel Angle

No fixings should be made through the boards into the flanges of the head channel. The arrow ( ) denotes the position of the uppermost board fixing,
which should be made into Gypframe GFS1 Fixing Strap (or stud nogging in C04. S01. P11 – construction detail 16). Continuous Gyproc FireStrip must be
installed as shown to maintain fire performance. Where there is a need for a deflection head in a 90 minute wall, the 120 minute solution can be used (refer to
Partitions introduction C04. S01. P11 – construction detail 16) or alternatively, please contact the British Gypsum Technical Advice Centre for further guidance.

C04. S07. P07 british-gypsum.com


GypWall quiet
GypWall quiet construction details (continued)

3 4

2 2

3 3

1 1

Partitions
4 4

C04
5

'T' Junction Alternative ‘T’ junction with Gypframe GA5 Internal Fixing Angle

5 6

2 2

3 3

1 1

4 4

‘T’ junction with GypWall classic partition Internal / external corner

1 Gyproc plasterboard 4 Isover insulation


2 Gypframe ‘C’ Stud 5 Gypframe GA5 Internal Fixing Angle
3 Gypframe 99 FC 50 Fixing Channel 6 Gyproc Sealant

Guidance must be sought from the relevant approval authority e.g. Building Control to establish if a cavity barrier is required (Approved Document B)

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S07. P08


GypWall quiet system components
GypWall quiet

Gypframe metal components ( Refer to C10. S02. P02 for details)

Gypframe ‘C’ Studs (48 S 50) Gypframe GFS1 Fixing Strap


Vertical stud providing acoustic and structural Used to support horizontal board joints.
performances designed to receive fixing of board to
one side along with a suitable Gyproc brace fixed to
the other side.

Gypframe Folded Edge Standard Floor & Ceiling Gypframe GA5 Internal Fixing Angle
Channels (50 FEC 50) Steel angle providing framing stability and
Standard floor and ceiling channels for retaining the board support.
Partitions

Gypframe studs at floor and ceiling junctions and


around openings to heights not exceeding 4200mm.

Gypframe Deep Flange Floor & Ceiling Channels Gypframe GA6 Splayed Angle
C04

(50 DC 60) Steel angle providing framing stability and


Floor and ceiling channels with deep flanges for board support.
retaining the Gypframe studs at floor and ceiling
junctions for partitions 4200mm to 8000mm high.
Also used around openings and in deflection heads
(maximum 30mm deflection).

Gypframe Extra Deep Flange Floor & Ceiling Gypframe Service Support Plate
Channels (50 EDC 70) For installation of 18mm plywood within
Floor and ceiling channels with extra deep flanges a partition cavity to support medium to
for retaining the Gypframe studs at floor and ceiling heavyweight fixtures.
junctions for partitions over 8000mm high. Also used
around openings and in deflection heads (maximum
50mm deflection).

Gypframe 99 FC 50 Fixing Channel


A versatile metal fixing channel used to support
medium weight fixtures on walls. Also used to
cross-brace the two rows of Gypframe stud.

Board products ( Refer to C10. S03. P02 for details)

Gyproc SoundBloc 1 Gyproc DuraLine1


Gypsum plasterboard with a high density core for Gypsum plasterboard with fire resistant additives
enhanced sound insulation performance. and a high density core for enhanced sound
insulation and impact resistance performance.

Gyproc FireLine1 Glasroc F firecase


Gypsum plasterboard with fire resistant additives. Non-combustible glass-reinforced gypsum board
used to form deflection head.

Gyproc Plank Gyproc CoreBoard


Standard gypsum plasterboard located as an Gypsum plasterboard with fire and moisture
inner layer. resistant additives used to form deflection head.

1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

C04. S07. P09 british-gypsum.com


GypWall quiet
GypWall quiet system components (continued)

Fixing products ( Refer to C10. S04. P02 for details)

British Gypsum Drywall Screws British Gypsum Wafer Head Drywall Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws
for fixing board to metal framing less than for fixing metal to metal framing less than
0.8mm thick. 0.8mm thick.

British Gypsum Collated Drywall Screws


Corrosion resistant self-tapping steel screws
for fixing board to metal framing less than
0.8mm thick.

Partitions
Plasterboard accessories ( Refer to C10. S05. P02 for details)

Gyproc Jointing Material Gyproc FireStrip

C04
Jointing compounds, ready mixes and adhesives A soft extruded linear intumescent gap sealer
for reinforcement and finishing of board joints. to maintain fire resistance located directly to
Primers and sealers for treatment of boards for the underside of the soffit when forming a
pre-decoration. deflection head.

Gyproc Control Joint Gyproc Sealant


To accommodate structural movement of up Used to seal air paths for optimum sound
to 7mm. insulation.

Gyproc edge and angle beads Gyproc Joint Tape


Protecting and enhancing board edges and corners A paper tape designed for reinforcement of flat
joints or internal angles.

Finishing products ( Refer to C10. S06. P02 for details)

Thistle MultiFinish ThistlePro DuraFinish


To provide a plaster skim finish on most common To provide a plaster skim finish and provide up to
backgrounds including undercoat plasters and 60% tougher resistance to accidental damage.
plasterboard. Can provide enhanced acoustic
performance.

Thistle BoardFinish ThistlePro PureFinish


To provide a plaster skim finish to To provide a plaster skim finish with
Gyproc plasterboards. ACTIVair technology. Used to finish most
common backgrounds including undercoat plasters
and plasterboard. For more information refer to
C02. S01. P49.

Thistle SprayFinish ThistlePro Magnetic


To provide a plaster skim finish by spray or hand To provide a plaster skim finish that provides an
application, ideal for medium to large projects. attraction to magnets used to finish a wide range
of backgrounds, including undercoat plasters and
plasterboard.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S07. P10


GypWall quiet

GypWall quiet system components (continued)

Finishing products ( Refer to C10. S06. P02 for details)

Thistle ProTape FT50 Thistle ProTape FT100


Self-adhesive 48mm wide glass fibre mesh tape. Self-adhesive 100mm wide glass fibre mesh tape.

Plaster accessories
Designed for the reinforcement and finishing of
board joints before plaster skimming.
Partitions

Insulation products ( Refer to C10. S09. P02 for details)

Isover Acoustic Partition Roll (APR 1200) Isover Acoustic Slab


Glass mineral wool for enhanced acoustic and Glass mineral wool to achieve acoustic
thermal performance. performance.
C04

C04. S07. P11 british-gypsum.com


GypWall quiet installation overview

GypWall quiet
This is intended to be a basic description of how the system is built.
For detailed installation guidance refer to the British Gypsum Site Book.

Partitions
Gypframe Floor & Ceiling Channels are Gypframe ‘C’ Studs are suitably fixed to The perimeter of each frame is then sealed
suitably fixed to the floor and soffit in abutments in two rows. with Gyproc Sealant.
two rows.

C04
Gypframe 'C' Studs are then friction fitted The two frameworks are braced with Mechanical and electrical services can be
into the Gypframe Floor & Ceiling Channels Gypframe 99 FC 50 Fixing Channel located within the partition cavity.
at the required centres. Door openings are attached to the Gypframe 'C' Studs with
constructed to the Heavy and Severe Duty British Gypsum Wafer Head Drywall Screws,
Rating door detail. two screws per junction.

Isover insulation is added to the partition Gyproc plasterboards are then fixed to the
cavity for increased acoustic performance. Gypframe framework with British Gypsum
Drywall Screws.

Additional information
For full installation details, refer to the
British Gypsum Site Book, available to
download from british-gypsum.com

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S07. P12


GypWall quiet iwl

GypWall quiet iwl


Independent twin frame high performance acoustic separating wall system

All our systems are covered by SpecSure® when using


genuine British Gypsum and Saint-Gobain Isover products
Partitions
C04
GypWall quiet iwl
GypWall quiet iwl
GypWall quiet iwl is a lightweight,
60 120
non-loadbearing high performance wall. The mins

use of an unbraced twin-frame ensures optimal


acoustic isolation, providing an enhanced
specification for buildings that are targeting 66 70
Rw dB
higher standards of health and well-being, for
example those designed to BREEAM frameworks

Partitions
or premium developments.
System can be skim
finished with
ThistlePro PureFinish.
Key benefits

C04
Refer to C02. S01. P49

— GypWall quiet iwl is an approved Robust Detail


specification (E-WS-2) meaning that it can
be used without the need for Pre-Completion Refer to C01. S01. P07
Testing to demonstrate compliance with
Approved Document E
— Structural columns can be accommodated within
the partition due to the twin-frame design
— GypWall quiet iwl can provide up to an estimated
120 minutes fire protection to structural steel
enclosed within its cavity
— Optimal resistance to impact noise transference
between adjacent spaces is achieved as a result
of the system's unbraced construction

You may also be interested in...


GypWall audio
If you are looking for solutions with an even higher
acoustic performance.
Refer to C04. S09. P02 – GypWall audio.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S08. P02


GypWall quiet iwl performance
GypWall quiet iwl

For details of when


to specify fire
resistance using EN
Refer to C02. S01. P05
Table 1a — Solutions to satisfy requirements of BS EN 1364-1

1 2 3
Partitions

Two layers of board fixed to the outside Two layers of board fixed to the outside Two layers of board fixed to the outside
faces of two Gypframe 48 I 50 ‘I’ Stud faces of two Gypframe 60 I 70 ‘I’ Stud faces of two Gypframe 60 I 50 ‘I’ Stud
frameworks with studs at 600mm frameworks with studs at 600mm frameworks with studs at 600mm
C04

centres. 50mm Isover Acoustic Partition centres. 100mm Isover Acoustic centres. 100mm Isover Acoustic
Roll (APR 1200) in the cavity (cavity Partition Roll (APR 1200) in the cavity Partition Roll (APR 1200) in the cavity
width 140mm). Linings as in table. (cavity width 190mm). (cavity width 190mm).
Linings as in table. Linings as in table.

Detail Partition Board type Lining Max. partition Sound insulation Duty rating Approx. System
thickness thickness height2 Rw (Rw + Ctr )2 weight reference
mm mm mm dB kg/m²

90 minutes fire resistance

1 200 Gyproc SoundBloc 2 x 15 2800 66 (58) Severe 55 A216014

2 250 Gyproc SoundBloc 2 x 15 3900 RD 3


Severe 55 A216007

3 250 Gyproc SoundBloc 2 x 15 3300 70 (62) / RD3 Severe 55 A216013

120 minutes fire resistance

1 200 Gyproc DuraLine 2 x 15 2800 67 (58) Severe 60 X216011

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is more onerous.
2
These British Gypsum Approved Systems are designed to achieve minimum DnT,w + Ctr 45dB, subject to Pre-Completion Testing
(Refer to Partitions introduction C04. S01. P04 – table 1)
3
RD = Robust Detail E-WS-2 - approved Robust Detail solution designed to achieve minimum DnT,w + Ctr 45dB. Minimum 60mm Gypframe ‘I’ Studs required.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the company’s fixing recommendations are strictly observed. Any variation in the specification should be checked with
British Gypsum.

C04. S08. P03 british-gypsum.com


GypWall quiet iwl
GypWall quiet iwl performance (continued) For details of when
to specify fire
resistance using BS
Refer to C02. S01. P05
Table 1b — Solutions to satisfy requirements of BS 476: Part 22: 1987

1 2 3

Partitions
Two layers of board fixed to the outside Two layers of board fixed to the outside Two layers of board fixed to the outside
faces of two Gypframe 48 I 50 ‘I’ Stud faces of two Gypframe 60 I 70 ‘I’ Stud faces of two Gypframe 60 I 50 ‘I’ Stud
frameworks with studs at 600mm frameworks with studs at 600mm frameworks with studs at 600mm

C04
centres. 50mm Isover Acoustic Partition centres. 100mm Isover Acoustic centres. 100mm Isover Acoustic
Roll (APR 1200) in the cavity (cavity Partition Roll (APR 1200) in the cavity Partition Roll (APR 1200) in the cavity
width 140mm). Linings as in table. (cavity width 190mm). (cavity width 190mm).
Linings as in table. Linings as in table.

Detail Partition Board type Lining Max. partition Sound insulation Duty rating Approx. System
thickness thickness height1 Rw (Rw + Ctr )2 weight reference
mm mm mm dB kg/m²

90 minutes fire resistance

1 200 Gyproc SoundBloc 2 x 15 2800 66 (58) Severe 55 A216014

2 250 Gyproc SoundBloc 2 x 15 3900 RD 3


Severe 55 A216007

3 250 Gyproc SoundBloc 2 x 15 3300 70 (62) / RD3 Severe 55 A216013

120 minutes fire resistance

1 200 Gyproc DuraLine 2 x 15 2800 67 (58) Severe 60 X216011

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on limiting deflection of L/240 at 200 Pa.
2
These British Gypsum Approved Systems are designed to achieve minimum DnT,w + Ctr 45dB, subject to Pre-Completion Testing
(Refer to Partitions introduction C04. S01. P04 – table 1)
3
RD = Robust Detail E-WS-2 - approved Robust Detail solution designed to achieve minimum DnT,w + Ctr 45dB. Minimum 60mm Gypframe ‘I’ Studs required.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the company’s fixing recommendations are strictly observed. Any variation in the specification should be checked with
British Gypsum.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S08. P04


GypWall quiet iwl

GypWall quiet iwl performance (continued) For details of when


to specify fire
resistance using EN / BS
Refer to C02. S01. P05
Table 2 — Solutions based on BS EN 1364-1 and BS 476: Part 21: 1987 1

Board type2 Lining thickness Fire resistance Section factor3


mm min A/V (Hp/A) m-¹
Gyproc SoundBloc 2 x 12.5 30 Up to 300
Gyproc SoundBloc 2 x 15 60 Up to 300
Gyproc SoundBloc 3 x 15 120 Up to 300

1
Estimated fire protection to structural steelwork within the partition cavity. Based on metal stud thermocouple data.
2
For improved and durability impact resistance, the outer layer of Gyproc FireLine or Gyproc SoundBloc can be replaced with a layer of 15mm Gyproc DuraLine.
3
Based on four-sided exposure, with no vertical joints aligning with the column, and boards not fixed to the column to maintain air space
Partitions

(10mm for BS or 50mm for EN).


C04

Table 3 — Maximum heights for Gypframe 'I' Studs at 600mm centres1

Stud type1 2 x 12.5mm boards maximum heights 2 x 15mm boards maximum heights

48 I 50 2700 2800
60 I 50 3000 3300
60 I 70 3600 3900
70 I 70 42002 43002
92 I 90 57002 /50002, 3 58002 /50002, 3
146 I 80 7200 /5000
2 2, 3
75002 /50002, 3

1
Based on a limiting deflection of L/240 at 200 Pa. Greater heights can be achieved by reducing stud centres for BS 476: Part 22: 1987. Contact the
Technical Advice Centre for further advice.
2
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to deflection criteria).
3
For BS EN 1364-1, the heights are limited to 5000mm maximum fire state field of application.

You may also be interested in...


GypWall audio
If you require a solution that allows greater
maximum heights.
Refer to C04. S09. P02 – GypWall audio.

C04. S08. P05 british-gypsum.com


GypWall quiet iwl design

GypWall quiet iwl


Building design Door openings

GypWall quiet iwl comprises a twin frame of Gypframe 'I' Studs at Any openings will require careful detailing if the acoustic
600mm centres within a twin row of Gypframe Floor & Ceiling performance is to be maintained. Specialist heavy acoustic door sets
Channels. may require additional support.

Planning — key factors


Framing surround for openings
The position of services and heavy fixtures should be
Where services such as horizontal ducts, fire dampers and access
pre-determined and their installation planned into the frame
panels are required to penetrate the wall, their position should be
erection stage.
pre-determined in order that a framed opening can be provided.
The openings should be constructed using established metal stud
All penetrations will need to be adequately stopped for fire
procedures.
and acoustics.

Partitions
Refer to Partitions introduction C04. S01. P16 – construction
Partition to structural steelwork junctions detail 28-31

When designing the layout of rooms requiring separation by sound


Cavity barriers
insulating walls abutting structural steelwork, consideration should

C04
be given to the potential loss of sound insulation performance Stone mineral wool (by others) cut neatly to fit across the cavity
through the steelwork. forms a suitable closure.

Refer to C02. S01. P10 – Building Acoustics.


Services

Fixing floor and ceiling channels Penetrations


Penetrations of fire-resistant or sound-insulating constructions
Gypframe Floor & Ceiling Channels must be securely fixed with a
for services need careful consideration to ensure that the
row of fixings at 600mm maximum centres. For 94mm channels
performance of the element is not downgraded. Consideration also
and above, two rows of staggered fixings are required, each row at
needs to be given to the services themselves so they do not act as
600mm centres and each fixing 25mm in from the flange. If the
the mechanism of fire spread or sound transmission.
floor is uneven, a 38mm thick timber sole plate equal to the width
of the channel should be used. Refer to C02. S01. P32 – Service installations.

If the concrete or screeded floor is new, consideration should be Electrical


given to the installation of a damp-proof membrane between the The installation of electrical services should be carried out in
floor surface and the channel or sole plate. accordance with BS 7671. The cut-outs in the studs can be used
for routing electrical and other small services. Refer to Partitions
Splicing introduction C04. S01. P07 – construction detail 2. Switch boxes
and socket outlets can be supported from Gypframe 99 FC 50 Fixing
Where the wall heights exceeds the available length of the
Channel fixed horizontally between studs, or a high performance
Gypframe 'I' Stud, sections of stud can be spliced together to the
socket box detail used where higher acoustic performance is
required length using 600mm lengths of the appropriate floor and
required.
ceiling channel, fixed with four British Gypsum Wafer Head Drywall
Screws in each flange to each side.
Independent support
Refer to Partitions introduction C04. S01. P07 – construction When designing for the installation of services such as fire
detail 1. dampers and associated ductwork through a GypWall partition,
consideration should be given to the size and weight of the
Partition to suspended ceiling junction damper - this will determine whether it can be supported directly
Where a GypWall metal stud partition is fixed to the framework from the partition or needs to be independently supported from the
of a CasoLine mf ceiling, in accordance with British Gypsum’s structure.
installation instructions, its permissible maximum height is equal Refer to Partitions introduction C04. S01. P17 – construction
to that of where it is fixed direct to a structural soffit of the same details 29-31.
height.

In situations where a GypWall metal stud partition passes


through a CasoLine mf ceiling, which is to both sides of the partition
and appropriately fixed to both this partition and perimeter
partitions / walls, consideration can be given to the lateral restraint
provided by the ceiling when developing the partition specification.

The relevant maximum height is the greater of the floor to


CasoLine mf ceiling or ceiling to structural soffit height. Care should
be taken during installation of tall partitions so as to not adversely
affect their performance.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S08. P06


GypWall quiet iwl design (continued)
GypWall quiet iwl

Deflection heads

Performance details apply to fixed head constructions. Partition


head deflection designs may be necessary to accommodate
Important information
deflections in the supporting floor. Deflection heads may also be
If using GypWall quiet iwl as Robust
required to the underside of roof structures subjected to positive
Details specification E-WS-2, note the
and negative pressures.
additional good practice installation
guidance provided:
For special detailing that minimises the loss of acoustic
performance: — Keep wall linings at least 190mm apart

Refer to C02. S01. P10 – Building acoustics. — Ensure that the quilt covers the whole
wall area without gaps
For deflection head design: — Make sure the quilt is compressed by
Partitions

twin frames
Refer to construction detail 7 within this section.
— Make sure there is no connection
Fixtures between the two leaves
Lightweight fixtures can be made directly to the partition linings. — Stagger joints in wall linings to avoid
C04

Medium weight fixtures can be made to Gypframe 99 FC 50 air paths


Fixing Channel. Heavyweight fixtures (to BS 5234) such as wash — Seal all joints in outer layer with tape
basins and wall cupboards, can be fixed using plywood secured by or caulk with sealant
Gypframe Service Support Plates.
— Follow the manufacturer's instructions
Refer to C02. S01. P33 – Service installations.

Board finishing
Refer to C08. S01. P02 – Finishes.

Tiling
SpecSure®
Tiles can be applied to the surface of lightweight partition systems.

Refer to C08. S04. P02 – Tiling All our systems are covered by SpecSure® when
using genuine British Gypsum and Saint-Gobain
Robust detail E-WS-2 Isover products.

If using GypWall quiet iwl as a Robust Detail compliant solution, refer


to the Robust Detail Handbook for principles. Further information
can be found at robustdetails.com or in HomeSpec, The White Book
Residential Specification Guide

C04. S08. P07 british-gypsum.com


GypWall quiet iwl construction details

GypWall quiet iwl


1 2

2 16

13
9
1
14

15

Partitions
5

2
6

7 13

C04
8

Base on concrete floor with screed 15mm deflection head - up to 60 minutes fire resistance

3 4

10
1

11

2
12
3

13 13

3 1

9
9

Junction with external wall when acoustic performance is a key


'T' junction consideration - Helps reduce flanking transmission

1 Gypframe 'I' Stud 9 Gyproc Sealant


2 Gyproc SoundBloc 10 External Cladding
3 Gypframe 'C' Stud 11 External wall stud framework
4 Gypframe Deep Flange Floor & Ceiling Channel 12 Cavity barrier (subject to regulatory requirements)
5 Gypframe Folded Edge Standard Floor & Ceiling Channel 13 Isover Acoustic Partition Roll (APR 1200)
6 Skirting 14 Gyproc CoreBoard or Glasroc F firecase
7 Screed on DPC 15 Imperforate ceiling
8 Bulk and fill with Gyproc jointing materials 16 Gyproc FireStrip

Guidance must be sought from the relevant approval authority e.g. Building Control to establish if a cavity barrier is required (Approved Document B)

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S08. P08


GypWall quiet iwl construction details (continued)
GypWall quiet iwl

5 6

1
1

4
4

2
Partitions

11
2

11
C04

'T' junction with GypWall classic partition Corner

12
10
11

25mm
7
25mm

25mm 8

5
9
6

2
1
4

25mm deflection head - 90 or 120 minute fire resistance

1 Gypframe 'I' Stud 7 Gypframe GA4 Steel Angle


2 Gyproc SoundBloc 8 Gypframe Deep Flange Floor & Ceiling Channel
3 Gypframe 'C' Stud 9 Stone mineral wool (by others)
4 Isover Acoustic Partition Roll (APR 1200) 10 Glasroc F firecase
5 Gypframe Folded Edge Standard Floor & Ceiling Channel 11 Gyproc Sealant
6 Gypframe Steel Angle or timber batten 12 Gyproc FireStrip

C04. S08. P09 british-gypsum.com


GypWall quiet iwl system components

GypWall quiet iwl


Gypframe metal components ( Refer to C10. S02. P02 for details)

Gypframe ‘I’ Studs (48 I 50, 60 I 50, 60 I 70, 70 I 50, Gypframe 99 FC 50 Fixing Channel
70 I 70, 92 I 90, 146 I 80) A versatile metal fixing channel used to support
Enhanced strength stud that allows for increased medium weight fixtures on walls.
partition height, without increasing partition width.
Designed to receive fixing of board to one side only.

Gypframe ‘C’ Studs (48 S 50, 60 S 50, 70 S 50, Gypframe GFS1 Fixing Strap
70 S 60, 92 S 50, 92 S 60, 92 S 10, 146 S 50) Used to support horizontal board joints and within
Vertical stud. Used at abutments and openings. deflection heads.

Partitions
Gypframe Folded Edge Standard Floor & Ceiling Gypframe GA5 Internal Fixing Angle
Channels (50 FEC 50, 62 FEC 50, 72 FEC 50, 94 FEC 50, Steel angle providing framing stability and

C04
148 FEC 50) board support.
Standard floor and ceiling channels for retaining the
Gypframe studs at floor and ceiling junctions and
around openings to heights not exceeding 4200mm.

Gypframe Deep Flange Floor & Ceiling Channels Gypframe GA6 Splayed Angle
(50 DC 60, 62 DC 60, 72 DC 60, 94 DC 60, 148 DC 60) Steel angle providing framing stability and
Floor and ceiling channels with deep flanges for board support.
retaining the Gypframe studs at floor and ceiling
junctions for partitions 4200mm to 8000mm high.
Also used around openings and in deflection heads
(maximum 30mm deflection).

Gypframe Extra Deep Flange Floor & Ceiling Gypframe Service Support Plate
Channels (50 EDC 70, 72 EDC 80, 94 EDC 70, For installation of 18mm plywood within
148 EDC 80) a partition cavity to support medium to
Floor and ceiling channels with extra deep flanges heavyweight fixtures.
for retaining the Gypframe studs at floor and ceiling
junctions for partitions over 8000mm high. Also used
around openings and in deflection heads (maximum
50mm deflection).

Board products continued ( Refer to C10. S03. P02 for details)

Gyproc SoundBloc1 Glasroc F firecase


Gypsum plasterboard with a high density core for Non-combustible glass-reinforced gypsum board
enhanced sound insulation performance. used to form deflection head.

Gyproc FireLine1 Gyproc CoreBoard


Gypsum plasterboard with fire resistant additives. Gypsum plasterboard with fire and moisture
resistant additives. Used to form deflection head.

Gyproc DuraLine1
Gypsum plasterboard with fire resistant additives
and a high density core for enhanced sound
insulation and impact resistance performance.

1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S08. P10


GypWall quiet iwl system components (continued)
GypWall quiet iwl

Fixing products ( Refer to C10. S04. P02 for details)

British Gypsum Drywall Screws British Gypsum Jack-Point Screws


Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws
for fixing board to metal framing less than for fixing board to metal framing 0.8mm thick and
0.8mm thick ('I' studs less than 0.6mm thick). greater (‘I’ studs 0.6mm thick and greater).

British Gypsum Collated Drywall Screws British Gypsum Wafer Head Jack-Point Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws for
for fixing board to metal framing less than fixing metal to metal framing 0.8mm thick and
0.8mm thick ('I' studs less than 0.6mm thick). greater ('I' studs 0.6mm thick and greater).
Partitions

British Gypsum Wafer Head Drywall Screws


Corrosion resistant self-tapping steel screws
for fixing metal to metal framing 0.8mm thick
C04

('I' studs less than 0.6mm thick).

Plasterboard accessories ( Refer to C10. S05. P02 for details)

Gyproc Jointing Materials Gyproc edge and angle beads


Jointing compounds, ready mixes and adhesives Protecting and enhancing board edges and corners
for reinforcement and finishing of board joints.
Primers and sealers for treatment of boards for
pre-decoration.

Gyproc Corner Tape Gyproc Joint Tape


A paper tape bonded to two corrosion resistant A paper tape designed for reinforcement of flat
steel strips. joints or internal angles.

Gyproc FireStrip Gyproc Sealant


A soft extruded linear intumescent gap sealer Used to seal air paths for optimum sound
to maintain fire resistance located directly to insulation.
the underside of the soffit when forming a
deflection head.

Gyproc Control Joint Gyproc Habito Corners


To accommodate structural movement of up A high strength, tapered co-polymer core offers
to 7mm. strong and uniform surface bonding for internal
and external angles in plasterboard constructions.

Gyproc AquaBead
An easy to apply, water, activated adhesive corner
bead, for reinforcing external 90°C angles in taped
and jointed plasterboard constructions.

C04. S08. P11 british-gypsum.com


GypWall quiet iwl system components (continued)

GypWall quiet iwl


Finishing products ( Refer to C10. S06. P02 for details)

Thistle MultiFinish ThistlePro DuraFinish


To provide a plaster skim finish on most common To provide a plaster skim finish and provide up to
backgrounds including undercoat plasters and 60% tougher resistance to accidental damage.
plasterboard. Can provide enhanced acoustic
performance.

Thistle BoardFinish ThistlePro PureFinish


To provide a plaster skim finish to To provide a plaster skim finish with
Gyproc plasterboards. ACTIVair technology. Used to finish most

Partitions
common backgrounds including undercoat plasters
and plasterboard. For more information refer to
C02. S01. P49.

C04
Thistle SprayFinish ThistlePro Magnetic
To provide a plaster skim finish by spray or hand To provide a plaster skim finish that provides an
application, ideal for medium to large projects. attraction to magnets used to finish a wide range
of backgrounds, including undercoat plasters and
plasterboard.

Thistle ProTape FT50 Plaster accessories


Self-adhesive 48mm wide glass fibre mesh tape. Designed for the reinforcement and finishing of
board joints before plaster skimming.

Thistle ProTape FT100


Self-adhesive 100mm wide glass fibre mesh tape.

Insulation products ( Refer to C10. S09. P02 for details)

Isover Acoustic Partition Roll (APR 1200)


Glass mineral wool for enhanced acoustic and
thermal performance.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S08. P12


GypWall quiet iwl installation overview
GypWall quiet iwl

This is intended to be a basic description of how the system is built.


For detailed installation guidance refer to the British Gypsum Site Book.
Partitions

Gypframe Floor & Ceiling Channels are Gypframe ‘C’ Studs are suitably fixed to The perimeter of each frame is then sealed
suitably fixed to the floor and soffit in abutments in two rows. with Gyproc Sealant.
two rows.
C04

Gypframe 'I' Studs are then friction fitted Door openings are constructed to the Heavy M&E services can be located within the
into the Gypframe Channels at the required and Severe Door Duty Rating detail. partition cavity.
centres.

Isover Acoustic Partition Roll (APR 1200) is Gyproc plasterboards are then fixed to the
added to the partition cavity. Gypframe framework with British Gypsum
Drywall Screws and British Gypsum
Jack-Point Screws.

Additional information
For full installation details, refer to the
British Gypsum Site Book, available to
download from british-gypsum.com

C04. S08. P13 british-gypsum.com


GypWall quiet iwl
Partitions
C04

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S08. P14


GypWall audio

GypWall audio
The ultimate sound insulating wall system

All our systems are covered by SpecSure® when using


genuine British Gypsum and Saint-Gobain Isover products
Partitions
C04
GypWall audio
GypWall audio
GypWall audio is a non-loadbearing, twin-frame
60 120
high performance wall system that provides mins

exceptionally high levels of sound insulation.


It is used to separate multi-use facilities, such
as lecture theatres, music rooms, multi-screen 67 80
Rw dB
cinemas, exhibition and conference centres, and
leisure centres.

Partitions
Key benefits System can be skim
finished with
ThistlePro PureFinish.
— Optimal sound insulation performance is

C04
Refer to C02. S01. P49

achieved through minimal bridging between


the Gyproc plasterboard linings and the
increased cavity size
Refer to C01. S01. P07
— The lightweight system combines high
levels of performance and a smaller footprint,
compared with masonry alternatives
— Up to 120 minutes fire protection can be
provided to structural steel enclosed within
the partition cavity of GypWall audio

You may also be interested in...


Looking for a high degree of reverberation control (for
example in a concert hall or auditorium)?
Refer to C09. S01. P04 – Sound absorbing solutions

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S09. P02


GypWall audio performance
GypWall audio

For details of when


to specify fire
resistance using EN
Refer to C02. S01. P05
Table 1a – Solutions to satisfy the requirements of BS EN 1364-1

Two frames of Gypframe 92 S 10 ‘C’ 1 2 3


Studs spaced at 600mm centres with
Gypframe 99 FC 50 Fixing Channel at
3600mm centres or Gypframe GAB3
Acoustic Braces at 3300mm centres.
Linings and insulation as in table.

4 5 6 7
Partitions
C04

Detail Partition Board type1 Lining Max. partition height2 mmIsover Sound Duty Approx. System
thickness thickness Fixing Channels GAB3 Acoustic Cladding insulation rating weight reference
mm mm braces at braces at Roll 40 Rw kg/m²
3600mm centres 3300mm centres mm (Rw + Ctr )
dB

60 minutes fire resistance

1 300 Gyproc SoundBloc 2 x 12.5 8000 8000 100 67 (56) Severe 47 A326001

1 300 Gyproc SoundBloc 2 x 15 8000 8000 100 69 (60) Severe 55 A326002


Gyproc Plank + 1 x 19 +
2 300 8000 8000 100 70 (60) Severe 58 A326003
Gyproc SoundBloc 1 x 12.5

120 minutes fire resistance

3 550 Gyproc SoundBloc 3 x 15 9000 9500 100 75 (69) Severe 80 A326016

4 550 Gyproc SoundBloc 3 x 15 9000 9500 2 x 100 76 (68) Severe 80 A326013


4 x 100 +
5 600 Gyproc SoundBloc 3 x 15 9000 9500 2 x 100 stone 77 (69) Severe 80 A326017
mineral wool3
3 x 100 +
6 600 Gyproc SoundBloc 3 x 15 9000 9500 2 x 100 stone 77 (69) Severe 80 A326018
mineral wool3
3 x 100 +
7 800 Gyproc SoundBloc 3 x 15 9500 9000 2 x 100 stone 80 (71) Severe 80 A326019
mineral wool3

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
For improved durability and impact resistance, the outer layer of Gyproc FireLine or Gyproc SoundBloc can be replaced with a layer of 15mm Gyproc DuraLine.
2
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to deflection
criteria). For heights over 8000mm, Gypframe Extra Deep Flange Floor and Ceiling Channel should be used at base and head. The maximum heights quoted are
limited by the fire state field of application or by limiting deflection L/240 at 200 Pa, whichever is more onerous.
3
Minimum density 62kg/m³.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.
Each pair of studs must be braced at least once, staggered to the adjacent pairs, irrespective of the partition height or specified bracing centres.

C04. S09. P03 british-gypsum.com


GypWall audio
GypWall audio performance (continued) For details of when
to specify fire
resistance using BS
Refer to C02. S01. P05
Table 1b – Solutions to satisfy the requirements of BS 476: Part 22: 1987

Two frames of Gypframe 92 S 10 ‘C’ 1 2 3


Studs spaced at 600mm centres with
Gypframe 99 FC 50 Fixing Channel at
3600mm centres or Gypframe GAB3
Acoustic Braces at 3300mm centres.
Linings and insulation as in table.

4 5 6 7

Partitions
C04
Detail Partition Board type1 Lining Max. partition height2 mm Isover Sound Duty Approx. System
thickness thickness Fixing Channels GAB3 Acoustic Cladding insulation rating weight reference
mm mm braces at braces at Roll 40 Rw kg/m²
3600mm centres 3300mm centres mm (Rw + Ctr )
dB
L/2403 L/1253 L/2403 L/1253
mm mm mm mm

60 minutes fire resistance

1 300 Gyproc SoundBloc 2 x 12.5 8000 9500 8000 10000 100 67 (56) Severe 47 A326001

90 minutes fire resistance

1 300 Gyproc SoundBloc 2 x 15 8000 9500 8000 10000 100 69 (60) Severe 55 A326002
Gyproc Plank + 1 x 19 +
2 300 8000 9500 8000 10000 100 70 (60) Severe 58 A326003
Gyproc SoundBloc 1 x 12.5

120 minutes fire resistance

3 550 Gyproc SoundBloc 3 x 15 9000 11500 9500 11500 100 75 (69) Severe 80 A326016

4 550 Gyproc SoundBloc 3 x 15 9000 11500 9500 11500 2 x 100 76 (68) Severe 80 A326013
4 x 100 +
5 600 Gyproc SoundBloc 3 x 15 9000 11500 9500 11500 2x 100 stone 77 (69) Severe 80 A326017
mineral wool4
3 x 100 +
6 600 Gyproc SoundBloc 3 x 15 9000 11500 9500 11500 2 x 100 stone 77 (69) Severe 80 A326018
mineral wool4
3 x 100 +
7 800 Gyproc SoundBloc 3 x 15 9500 11500 9000 11500 2 x 100 stone 80 (71) Severe 80 A326019
mineral wool4

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com
1
For improved durability and impact resistance, the outer layer of Gyproc FireLine or Gyproc SoundBloc can be replaced with a layer of 15mm Gyproc DuraLine.
2
For heights between 4200mm and 8000mm, Gypframe Deep Flange Floor & Ceiling Channel should be used at base and at head (subject to deflection
criteria). For heights over 8000mm, Gypframe Extra Deep Flange Floor and Ceiling Channel should be used at base and head.
3
Refer to deflection criteria, in design section.
4
Minimum density 62kg/m3.
The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and filled,
or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover components
are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with British Gypsum.
Each pair of studs must be braced at least once, staggered to the adjacent pairs, irrespective of the partition height or specified bracing centres.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S09. P04


GypWall audio

GypWall audio performance (continued) For details of when


to specify fire
resistance using EN / BS
Refer to C02. S01. P05
Table 2 — Solutions based on BS EN 1364-1 and BS 476: Part 21: 1987 1

Board Lining Fire Section factor3


type2 thickness protection A/V (Hp/A)
mm min m-1

Gyproc SoundBloc 2 x 12.5 30 Up to 300

Gyproc SoundBloc 2 x 15 60 Up to 300

Gyproc Plank + Gyproc SoundBloc 1 x 19 + 1 x 12.5 60 Up to 300

Gyproc Plank + Gyproc FireLine 1 x 19 + 1 x 12.5 60 Up to 300

Gyproc SoundBloc 3 x 15 120 Up to 300


Partitions

1
Estimated fire protection to structural steelwork within the partition cavity. Based on metal stud thermocouple data.
2
For improved durability and impact resistance, the outer layer of Gyproc FireLine or Gyproc SoundBloc can be replaced with a layer of 15mm Gyproc DuraLine.
3
Based on four-sided exposure, with no vertical joints aligning with the column, and boards not fixed to the column to maintain air space
(10mm for BS or 50mm for EN).
C04

Table 3 – Acoustic performance of GypWall audio at low frequencies


Detail Overall wall Board type1 Lining Isover Cladding Octave band sound reduction System
thickness thickness Roll 40 index (R) dB Rw dB reference
mm mm mm
63Hz 125Hz 250Hz

1 300 Gyproc SoundBloc 2 x 12.5 100 29.4 41.8 55.6 67 A326001

1 300 Gyproc SoundBloc 2 x 15 100 35.6 45.8 57.5 69 A326002


Gyproc Plank + 1 x 19 +
2 300 100 34.8 46.1 58.6 70 A326003
Gyproc SoundBloc 1 x 12.5
3 550 Gyproc SoundBloc 3 x 15 100 37.9 56.7 63.0 75 A326016

4 550 Gyproc SoundBloc 3 x 15 2 x 100 41.1 55.7 62.0 76 A326013


4 x 100 +
5 600 Gyproc SoundBloc 3 x 15 2 x 100 stone 46.0 55.0 65.0 77 A326017
mineral wool2
3 x 100 +
6 600 Gyproc SoundBloc 3 x 15 2 x 100 stone 46.5 55.7 63.8 77 A326018
mineral wool2
3 x 100 +
7 800 Gyproc SoundBloc 3 x 15 2 x 100 stone 51.3 57.5 67.1 80 A326019
mineral wool2

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
For improved durability and impact resistance, the outer layer of Gyproc FireLine or Gyproc SoundBloc can be replaced with a layer of 15mm Gyproc DuraLine.
2
Minimum density 62kg/m3.

C04. S09. P05 british-gypsum.com


GypWall audio design

GypWall audio
Building design Control joints

GypWall audio comprises braced twin rows of Gypframe 92 S 10 'C' Control joints may be required in the partition to relieve stresses
Studs installed at 600mm centres within Gypframe Floor & Ceiling induced by expansion and contraction of the structure (refer to
Channels. Partitions introduction C04. S01. P10 – construction detail 12). They
should coincide with movement joints within the surrounding structure.
Planning – key factors
Deflection heads
The position of services and heavy fixtures should be
pre-determined and their installation planned into the frame Partition head deflection designs may be necessary to
erection stage. accommodate deflections in the supporting floor. Deflection heads
may also be required to the underside of roof structures subjected
to positive and negative pressures.
Designers and site management should give full consideration to

Partitions
the potential exposure of GypWall audio to differential pressures, Refer to construction details 4 and 5 within this section.
such as wind loadings during installation.
Deflection criteria
Fixing floor and ceiling channels
Our normal recommendation is to build to a deflection criteria
Gypframe Floor & Ceiling Channels must be securely fixed with two L/240 at 200 Pa, however it is common for this system to be built

C04
rows of staggered fixings, each row at 600mm centres and each to L/125 at 200 Pa (BS 476: Part 22: 1987 fire resistance only).
fixing 25mm in from the flange. If the floor is uneven, a 38mm thick
timber sole plate equal to the width of the channel should be used. Partitions built to a maximum height based on L/125 at 200 Pa
If the concrete or screeded floor is new, consideration should be will exhibit greater deflection compared to partitions built to
given to the installation of a damp-proof membrane between the a maximum height based on L/240 at 200 Pa. Partitions with
floor surface and the channel or sole plate. deflection characteristics outside the standard L/240 criteria
will exhibit more flex during installation and in general use,
Splicing and therefore we recommend you verify the acceptibility of the
deflections with the relevant interested parties before
To extend studs, overlap by 600mm (minimum). Fix together using
specifying / installing partitions based on L/125 criteria.
British Gypsum Wafer Head Drywall Screws or steel pop rivets (two
to each flange), or by using the Gyproc Stud Interlocking Tool twice
Cross bracing
to each flange.
Laboratory tests were carried out on walls without bracing. The
Refer to Partitions introduction C04. S01. P07 – construction
results, however, are a realistic representation of site conditions in
detail 1.
which Gypframe 99 FC 50 Fixing Channel cross-braces are fitted
at the recommended 3600mm maximum centres, provided that
Partition to structural steelwork junctions
appropriate measures are taken on site to eliminate flanking sound
When designing the layout of rooms requiring separation by sound transmission. All braces must be staggered by half distance of the
insulating walls abutting structural steelwork, consideration should brace centres. Test evidence is provided by British Gypsum Report
be given to the potential loss of sound insulation performance ATR 1299, where a site test on a large multi-screen cinema wall
through the steelwork. achieved comparable performance to the equivalent specification
Refer to C02. S01. P10 – Building acoustics. tested in the laboratory without bracing.

Door openings Acoustic designers may prefer the option of a resilient acoustic
brace. The Gypframe GAB3 Acoustic Brace has been shown in tests
Any openings will require careful detailing if the acoustic
not to downgrade acoustic performance in laboratory conditions.
performance is to be maintained. Specialist heavy acoustic doorsets
However, as a result of the mechanics of this brace fixing centres
may require additional support.
should be reduced from 3600mm to 3300mm, staggered by half
distance of brace centres. Maximum recommended wall heights
Framing surround for openings
will vary.
Where services such as horizontal ducts, fire dampers and access
Refer to tables 1a and 1b within this section.
panels are required to penetrate the wall, their position should be
pre-determined in order that a framed opening can be provided.
The minimum and maximum wall widths for which
Refer to C04. S01. P16 – Service installations. Gypframe GAB3 Acoustic Brace can be used without modification
are 300mm and 600mm respectively. Likewise, the minimum and
Cavity barriers maximum cavity width between the two stud frames for which
Stone mineral wool cut neatly to fit across the cavity forms Gypframe GAB3 Acoustic Brace can be used without modification
a suitable closure. are 100mm and 400mm respectively.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S09. P06


GypWall audio design (continued)
GypWall audio

The Gypframe GAB3 Acoustic Brace may be cut using a hacksaw Fixtures
or powertool. If required, the Gypframe GAB Acoustic Brace can be
Lightweight fixtures can be made directly to the partition linings.
extended by fixing a short length of Gypframe 92 S 10 ‘C’ Stud to
Medium weight fixtures can be made to Gypframe 99 FC 50
one brace with four British Gypsum Wafer Head Jack-Point Screws
Fixing Channel. Heavyweight fixtures (to BS 5234) such as wash
(ensure a 75mm minimum overlap to each stud with no contact
basins and wall cupboards, can be fixed using plywood secured by
to board lining). The short length of stud should also be fixed to
Gypframe Service Support Plates.
the vertical studs with four British Gypsum Wafer Head Jack-Point
Screws. Refer to C02. S01. P33 – Service installations.

Care should be taken to ensure Gypframe GAB3 Acoustic Braces Access for maintenance
are correctly and fully engaged and not mis-aligned. Where
Gyproc Profilex Access Panels are available to provide access for
partition heights are specified based on lateral restraint from a
maintenance. Access panels must be fully compatible with drywall
Partitions

suitable ceiling, either this ceiling should be in place at the time of


construction and match the fire rating of the partition.
installation or temporary restraint should be used.
Refer to profilex.co.uk for further information.
Each pair of studs must be braced at least once, staggered to the
adjacent pairs, irrespective of the partition height or specified Board finishing
C04

bracing centres.
Refer to C08. S01. P02 – Finishes

Board fixing
Tiling
In common with building practice, the twin frame wall should be
Tiles can be applied to the surface of lightweight partition systems.
boarded progressively from each side of the partition. This will help
prevent differential loadings on the framework. Refer to C08. S04. P02 – Tiling

Services

Penetrations
Penetrations of fire-resistant or sound-insulating constructions SpecSure®
for services need careful consideration to ensure that the
performance of the element is not downgraded. Consideration also All our systems are covered by SpecSure® when
needs to be given to the services themselves so they do not act as using genuine British Gypsum and Saint-Gobain
the mechanism of fire spread or sound transmission. Isover products.

Refer to C02. S01. P32 – Service installations.

Electrical
The installation of electrical services should be carried out in
accordance with BS 7671. The cut-outs in the studs can be used
for routing electrical and other small services (refer to Partitions
introduction C04. S01. P07 – construction detail 2). Switch boxes
and socket outlets can be supported from Gypframe 99 FC 50 Fixing
Channel fixed horizontally between studs, or a high performance
socket box detail used where higher acoustic performance is
required.

Independent support
When designing for the installation of services such as fire
dampers and associated ductwork through a GypWall partition,
consideration should be given to the size and weight of the
damper - this will determine whether it can be supported directly
from the partition or needs to be independently supported from
the structure.

Refer to Partitions introduction C04. S01. P17 – construction


details 29-31.

C04. S09. P07 british-gypsum.com


GypWall audio construction details

GypWall audio
1
3

600mm
2

Partitions
5

C04
Splicing and acoustic bracing

3
600mm

Splicing and solid bracing

1 Gyproc plasterboard 4 Isover Cladding Roll 40


2 Gypframe 92 S 10 ‘C’ Stud 5 Gypframe GAB3 Acoustic Brace
3 Splice - 600mm overlap with three 6 Brace formed from Gypframe 99 FC 50 Fixing Channel (staggered)
British Gypsum Wafer Head Jack-Point Screws into each flange

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S09. P08


GypWall audio construction details (continued)
GypWall audio

3 4 11
9
4 10

6 6

15mm
15mm 13

20mm
1
12
Partitions

5
1

2
C04

Deflection head for 15mm downward movement and


3 60 minutes fire resistance

5
14

10
6

25mm
13

25mm
15

12
30mm

7 2

4
6

Deflection head for ±25mm movement and 60 minutes


Head and base fire resistance

1 Gyproc plasterboard 9 Gypframe Deep Flange Floor & Ceiling Channel suitably fixed through
fire-stop to structure
2 Gypframe 92 S 10 ‘C’ Stud
10 Gyproc FireStrip
3 Gypframe 99 FC 50 Fixing Channel
11 Gyproc CoreBoard or Glasroc F firecase
4 Gypframe Floor & Ceiling Channel
12 Gypframe GFS1 Fixing Strap
5 Isover Cladding Roll 40
13 Gypframe GA4 Steel Angle
6 Gyproc Sealant
14 Timber head plate suitably fixed to structure
7 Bulk fill with Gyproc jointing materials (where gap exceeds 5mm)
15 Gypframe Extra Deep Flange Floor & Ceiling Channel suitably fixed to
8 Skirting
timber head plate

No fixings should be made through the boards into the flanges of the head channel. The arrow ( ) denotes the position of the uppermost board fixing,
which should be made into Gypframe GFS1 Fixing Strap. Continuous Gyproc FireStrip must be installed as shown to maintain fire performance.

C04. S09. P09 british-gypsum.com


GypWall audio construction details (continued)

GypWall audio
6 7

2 2

3 3

1 1

Partitions
6

C04
4 4

‘T’ junction Alternative ‘T’ junction using GA5 Internal Fixing Angle

8 9

2 2

3 3

1 1

‘T’ junction with a low acoustic performance


GypWall classic partition Internal / external corner

1 Gyproc plasterboard 4 Isover Cladding Roll 40


2 Gypframe 92 S 10 ‘C’ Stud 5 Gypframe GA5 Internal Fixing Angle
3 Gypframe 99 FC 50 Fixing Channel 6 Gyproc Sealant

Guidance must be sought from the relevant approval authority e.g. Building Control to establish if a cavity barrier is required (Approved Document B)

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S09. P10


GypWall audio system components
GypWall audio

Gypframe metal components ( Refer to C10. S02. P02 for details)

Gypframe ‘C’ Studs 92 S 10 Gypframe GAB3 Acoustic Brace


Vertical stud providing acoustic and structural To cross-brace two rows of Gypframe studs for
performances designed to receive fixing of board. optimum acoustic performance.

Gypframe Folded Edge Standard Floor & Ceiling Gypframe GFS1 Fixing Strap
Channels 94 FEC 50 Used to support horizontal board joints and within
Standard floor and ceiling channels for retaining the deflection heads.
Partitions

Gypframe studs at floor and ceiling junctions and


around openings to heights not exceeding 4200mm.

Gypframe Deep Flange Floor & Ceiling Channels Gypframe GA5 Internal Fixing Angle
94 DC 60 Steel angle providing framing stability and
C04

Floor and ceiling channels with deep flanges for board support.
retaining the Gypframe studs at floor and ceiling
junctions for partitions 4200mm to 8000mm high.
Also used around openings and in deflection heads
(maximum 30mm deflection).

Gypframe Extra Deep Flange Floor & Ceiling Gypframe GA6 Splayed Angle
Channels 94 EDC 70 Steel angle providing framing stability and
Floor and ceiling channels with extra deep flanges board support.
for retaining the Gypframe studs at floor and ceiling
junctions for partitions over 8000mm high. Also used
around openings and in deflection heads (maximum
50mm deflection).

Gypframe 99 FC 50 Fixing Channel Gypframe Service Support Plate


A versatile metal fixing channel used to support For installation of 18mm plywood within
medium weight fixtures on walls. Also used to a partition cavity to support medium to
cross-brace the two rows of Gypframe studs. heavyweight fixtures.

Board products ( Refer to C10. S03. P02 for details)

Gyproc SoundBloc1 Gyproc WallBoard1


Gypsum plasterboard with a high density core for Standard gypsum plasterboard.
enhanced sound insulation performance.

Gyproc Plank Gyproc DuraLine1


Standard gypsum plasterboard located as an Gypsum plasterboard with fire resistant additives
inner layer. and a high density core for enhanced sound
insulation and impact resistance performance.
Used as a substitute outer board layer.

Gyproc FireLine1 Glasroc F firecase


Gypsum plasterboard with fire resistant additives. Non-combustible glass-reinforced gypsum board
used to form deflection head.

1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

C04. S09. P11 british-gypsum.com


GypWall audio system components (continued)

GypWall audio
Board products ( Refer to C10. S03. P02 for details)

Gyproc CoreBoard
Gypsum plasterboard with fire and moisture
resistant additives used to form deflection head.

Fixing products ( Refer to C10. S04. P02 for details)

British Gypsum Jack-Point Screws British Gypsum Wafer Head Jack-Point Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws

Partitions
for fixing board to metal framing 0.8mm thick and for fixing metal to metal framing 0.8mm thick
greater (‘I’ studs 0.6mm thick and greater). and greater.

Plasterboard accessories ( Refer to C10. S05. P02 for details)

C04
Gyproc Jointing Materials Gyproc Control Joint
Jointing compounds, ready mixes and adhesives To accommodate structural movement of up
for reinforcement and finishing of board joints. to 7mm.
Primers and sealers for treatment of boards for
pre-decoration.

Gyproc FireStrip Gyproc edge and angle beads


A soft extruded linear intumescent gap sealer Protecting and enhancing board edges and corners.
to maintain fire resistance located directly to
the underside of the soffit when forming a
deflection head.

Gyproc Sealant Gyproc Joint Tape


Used to seal air paths for optimum sound A paper tape designed for reinforcement of flat
insulation. joints or internal angles.

Finishing products ( Refer to C10. S06. P02 for details)

Thistle MultiFinish ThistlePro DuraFinish


To provide a plaster skim finish on most common To provide a plaster skim finish and provide up to
backgrounds including undercoat plasters and 60% tougher resistance to accidental damage.
plasterboard.

Thistle BoardFinish ThistlePro PureFinish


To provide a plaster skim finish to To provide a plaster skim finish with
Gyproc plasterboards. ACTIVair technology. Used to finish most
common backgrounds including undercoat plasters
and plasterboard. For more information refer to
C02. S01. P49.

Thistle SprayFinish Plaster accessories


To provide a plaster skim finish by spray or hand Designed for the reinforcement and finishing of
application, ideal for medium to large projects. board joints before plaster skimming.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S09. P12


GypWall audio system components (continued)
GypWall audio

Finishing products ( Refer to C10. S06. P02 for details)

Thistle ProTape FT50 Thistle ProTape FT100


Self-adhesive 48mm wide glass fibre mesh tape. Self-adhesive 100mm wide glass fibre mesh tape.

Insulation products ( Refer to C10. S09. P02 for details)

Isover Cladding Roll 40 Stone mineral wool (62kg/m³ by others)


Glass mineral wool roll for acoustic performance. For enhanced acoustic performance at
Partitions

low frequency.
C04

C04. S09. P13 british-gypsum.com


GypWall audio system installation overview

GypWall audio
This is intended to be a basic description of how the system is built.
For detailed installation guidance refer to the British Gypsum Site Book.

Partitions
Gypframe Floor & Ceiling Channels are suitably Gypframe 92 S 10 'C' Studs are fixed at Gyproc Sealant is applied to the frame
fixed to the floor and soffit in two rows. abutments and door openings in two rows. perimeters to seal airpaths.

C04
Gypframe 92 S 10 'C' Studs are then friction The Gypframe 92 S 10 'C' Studs are then or staggered Gypframe 99 FC 50 Fixing
fitted into the Gypframe Channels at the braced together in pairs with either Channels.
required centres, and door openings are staggered Gypframe GAB3 Acoustic Braces,
constructed to the Heavy and Severe Duty
Rating door detail.

M&E services can be located within the Insulation is added to the partition cavity. Gyproc plasterboards are then fixed to
partition cavity. the Gypframe framework with
British Gypsum Jack-Point Screws.

Additional information
For full installation details, refer to the
British Gypsum Site Book, available to
download from british-gypsum.com

When applying muliple layers of board,


ensure that all board joints are staggered
on both sides of the partition.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S09. P14


GypWall rapid dB Plus

GypWall rapid dB Plus


Metal stud housing partition system

All our systems are covered by SpecSure® when using


genuine British Gypsum and Saint-Gobain Isover products
Partitions
C04
GypWall rapid dB Plus
GypWall rapid dB Plus
GypWall rapid dB Plus is a non-loadbearing, high 30
performance internal wall partition system for mins

use in residential developments. This versatile


system incorporates Gyproc SoundBloc rapid
linings and Gypframe AcouStuds to provide 40 46
robust acoustic solutions that comply with
Rw dB

Building Regulations Approved Document E

Partitions
(England and Wales) and Technical Handbook
Section 5 (Scotland). There are two build System can be skim
finished with
ThistlePro PureFinish.
solutions: 450mm stud framing without

C04
Refer to C02. S01. P49

noggings, and 900mm stud framing with


horizontal noggings.
Refer to C01. S01. P07

Key benefits
— GypWall rapid dB Plus combines high levels of
performance and a narrow footprint, compared
with timber and masonry alternatives
— Speed and efficiency of installation are achieved
through the use of lightweight Gypframe stud
framing and single layer Gyproc SoundBloc rapid
linings, with a special width and thickness
configuration
— Services are easily accommodated within the
partition; through the pre-finished service
cut-outs within Gypframe AcouStuds

You may also be interested in...


ThistlePro Magnetic plaster attracts magnets and turns any wall, in any room into an inspiring
interactive gallery or notice board that homeowners can change as often as they like: no fuss,
no mess.

It can be decorated with standard emulsion paint or combined with specialist paint finishes,
including blackboard and whiteboard.
Refer to Products C10. S06. P06 – Plasters and plaster accessories

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S10. P02


GypWall rapid dB Plus performance
GypWall rapid dB Plus

For details of when


to specify fire
resistance using EN
Refer to C02. S01. P05
Table 1a – Solutions to satisfy the requirements of BS EN 1364-1

1 2 3

One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 43 AS 50 AcouStuds at 900mm centres. Gypframe 43 AS 50 AcouStuds at 450mm centres. Gypframe 70 AS 50 AcouStuds at 450mm centres.
43mm Gypframe GWR2 mid-height nogging. Linings as in table. Linings as in table.
Linings as in table.
Partitions

4 5 6
C04

One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 43 AS 50 AcouStuds at 900mm centres. Gypframe 43 AS 50 AcouStuds at 450mm centres. Gypframe 70 AS 50 AcouStuds at 450mm centres.
43mm Gypframe GWR2 mid-height nogging. 25mm Isover Acoustic Partition Roll (APR 1200). 25mm Isover Acoustic Partition Roll (APR 1200).
25mm Isover Acoustic Partition Roll (APR 1200). Linings as in table. Linings as in table.
Linings as in table.

Detail Partition Board type1 Lining Maximum partition Sound insulation Duty rating Approx. System
thickness thickness height RwdB weight reference
mm mm mm kg/m²

30 minutes fire resistance

1 75 Gyproc SoundBloc rapid 1 x 15 2400 40 Medium 27 A139A001

2 75 Gyproc SoundBloc rapid 1 x 15 2700 40 Medium 27 A139A005

5 75 Gyproc SoundBloc rapid 1 x 15 2700 43 Medium 28 A139A006

4 75 Gyproc SoundBloc rapid 1 x 15 2400 44 Medium 28 A139A003

3 102 Gyproc SoundBloc rapid 1 x 15 2700 42 Medium 28 A139A011

6 102 Gyproc SoundBloc rapid 1 x 15 2700 46 Medium 29 A139A012

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
The maximum heights quoted are limited by the fire state field of application or by limiting deflection of L/240 at 200 Pa, whichever is the more onerous.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

C04. S10. P03 british-gypsum.com


GypWall rapid dB Plus
GypWall rapid dB Plus performance (continued) For details of when
to specify fire
resistance using BS
Refer to C02. S01. P05
Table 1b – Solutions to satisfy the requirements of BS 476: Part 22: 1987

1 2 3

One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 43 AS 50 AcouStuds at 900mm centres. Gypframe 43 AS 50 AcouStuds at 450mm centres. Gypframe 70 AS 50 AcouStuds at 450mm centres.
43mm Gypframe GWR2 mid-height nogging. Linings as in table. Linings as in table.
Linings as in table.

Partitions
4 5 6

C04
One layer of board each side of One layer of board each side of One layer of board each side of
Gypframe 43 AS 50 AcouStuds at 900mm centres. Gypframe 43 AS 50 AcouStuds at 450mm centres. Gypframe 70 AS 50 AcouStuds at 450mm centres.
43mm Gypframe GWR2 mid-height nogging. 25mm Isover Acoustic Partition Roll (APR 1200). 25mm Isover Acoustic Partition Roll (APR 1200).
25mm Isover Acoustic Partition Roll (APR 1200). Linings as in table. Linings as in table.
Linings as in table.

Detail Partition Board type1 Lining Maximum partition Sound insulation Duty rating Approx. System
thickness thickness height RwdB weight reference
mm mm mm kg/m²

30 minutes fire resistance

1 75 Gyproc SoundBloc rapid 1 x 15 2400 40 Medium 27 A139A001

2 75 Gyproc SoundBloc rapid 1 x 15 2700 40 Medium 27 A139A005

5 75 Gyproc SoundBloc rapid 1 x 15 2700 43 Medium 28 A139A006

4 75 Gyproc SoundBloc rapid 1 x 15 2400 44 Medium 28 A139A003

3 102 Gyproc SoundBloc rapid 1 x 15 2700 42 Medium 28 A139A011

6 102 Gyproc SoundBloc rapid 1 x 15 2700 46 Medium 29 A139A012

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Based on a limiting deflection of L/240 at 200 Pa.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked with
British Gypsum.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S10. P04


GypWall rapid dB Plus design
GypWall rapid dB Plus

Building design Fixtures

There are two build solutions; 450mm stud framing without Lightweight fixtures can be made directly to the partition linings.
noggings, and 900mm stud framing with horizontal noggings. Medium weight fixtures can be made to Gypframe 99 FC 50 Fixing
Channel. Heavyweight fixtures (to BS 5234), such as wash basins
Planning – key factors and wall cupboards, can be fixed using plywood secured with
Gypframe Service Support Plate.
The position of services should be pre-determined and their
installation planned into the frame erection stage. Refer to C02. S01. P33 – Service installations.

Partition to structural steelwork junctions Board finishing


When designing the layout of rooms requiring separation by sound Refer to C08. S01. P02 – Finishes.
insulating walls abutting structural steelwork, consideration should
Partitions

be given to the potential loss of sound insulation performance Tiling


through the steelwork. Tiles can be applied to the surface of lightweight partition systems.

Refer to C02. S01. P10 – Building acoustics. Refer to C08. S04. P02 – Tiling.

Cavity barriers In intermittently wet use areas, such as around baths,


C04

Gyproc SoundBloc rapid mr should be used in accordance with NHBC


Gyproc SoundBloc rapid screw-fixed into the web of perimeter recommendations. Two coats of Gyproc Drywall Sealer applied to the face of
standard grade plasterboards, with the edges adequately protected from
channels or vertical studs will provide a satisfactory closure to
moisture may also be suitable to receive a tile finish. The application of
flame and smoke. Gyproc Drywall Sealer provides surface water absorption resistance only, and
does not meet the performance requirements for moisture resistant grade
Refer to C06. S07. P02 – Cavity barriers. boards as defined in BS EN 520, type H1.

Services

Electrical
The installation of electrical services should be carried out in SpecSure®
accordance with BS 7671. The cut-outs in the studs can be used
for routing electrical and other small services (Refer to Partitions All our systems are covered by SpecSure® when
introduction C04. S01. P07 – construction detail 2a). Switch boxes using genuine British Gypsum and Saint-Gobain
and socket outlets can be supported from Gypframe 99 FC 50 Fixing Isover products.
Channel fixed horizontally between studs, or a high performance
socket box detail used where higher acoustic performance is
required.

Cables should be protected by conduit, or other suitable


precautions taken to prevent abrasion when they pass through
the metal frame. Service cut-outs should be aligned to allow easy
installation of service. If studs require cutting, cut from the same
end of each stud to ensure cut-out alignment.

Heating pipes
Where heating pipes, particularly micro-bore systems, are to be
located within the partition, it is recommended that only one pipe
is passed through each aperture in the metal framework. If this
cannot be accommodated for whatever reason, it may then be
necessary to incorporate proprietary pipe restraining clips or other
means of keeping the pipes apart to prevent vibration noise.

Ducts
Where a large number of electrical cables or pipes have to be
accommodated, a service duct can be created by closing up the stud
centres to 450mm and omitting the intermediate nogging.
Electrical cables should be attached using an appropriate cable
retaining device in order to satisfy the requirements of BS 7671.

C04. S10. P05 british-gypsum.com


GypWall rapid dB Plus construction details

GypWall rapid dB Plus


1 2

3 4

1 3

Partitions
9

C04
4
Junction with masonry
(900mm stud centres with horizontal noggings)

4
2
1

5
7
3
9
6

5 8

Head and base Junction with masonry


(900mm stud centres with horizontal noggings) (900mm stud centres with horizontal noggings)

4 5

1
4

2 3

Intermediate stud Internal / external corner


(900mm stud centres with horizontal noggings) (900mm stud centres with horizontal noggings)

1 15mm Gyproc SoundBloc rapid 6 Bulk fill with Gyproc jointing materials (where gap exceeds 5mm)
2 Gypframe 43 AS 50 AcouStud 7 Skirting
3 Gypframe GWR3 Floor and Ceiling Channel 8 Blockwork
4 Gypframe GWR2 Nogging Channel (only required when studs are 9 DriLyner basic wall lining system
installed at 900mm centres)
5 Gyproc Sealant

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S10. P06


GypWall rapid dB Plus construction details (continued)
GypWall rapid dB Plus

6 7
5

8
1
4
4

2
3
5
Partitions

‘T’ junction Splayed angle


(900mm stud centres with horizontal noggings) (900mm stud centres with horizontal noggings)
C04

8 9

1
3
2

4
4

Wall abutment Framing intersection


(900mm stud centres with horizontal noggings) (900mm stud centres with horizontal noggings)

10

Additional framing for heavy fixtures

1 15mm Gyproc SoundBloc rapid 5 Gypframe GA6 Splayed Angle


2 Gypframe 43 AS 50 AcouStud 6 Additional framing
3 Gypframe GWR3 Floor and Ceiling Channel 7 Wash basin
4 Gypframe GWR2 Nogging Channel (only required when studs are 8 Gyproc Sealant
installed at 900mm centres)

C04. S10. P07 british-gypsum.com


GypWall rapid dB Plus construction details (continued)

GypWall rapid dB Plus


11
2

Section A–A

Partitions
1

C04
300mm
B

Section B–B
A

A
4

150mm

Door frame detailing to BS 5234 - Medium Duty Rating, studs either side of door opening fully sleeved

12
A

Snip legs
A

Bend up 2
90°

A Bend
Bend up 5
down
90°
A 180°

Bend
down A = depth from door head to legs of head channel
180° B = width of formed door head

Forming door head where studs either side of door opening have a timber ground fitted

1 Gypframe AcouStud fully sleeved with Gypframe channel 5 Finished assembly fixed to Gypframe AcouStuds with
(both sides of opening) British Gypsum Wafer Head Drywall Screws
2 Gypframe Floor & Ceiling channel 6 Mitre cuts
3 Gypframe Floor & Ceiling channel cut and bent to form door head
4 Door set

Denotes location of fixings into floor.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S10. P08


GypWall rapid dB Plus system components
GypWall rapid dB Plus

Gypframe metal components ( Refer to C10. S02. P02 for details)

Gypframe AcouStud (43 AS 50, 70 AS 50) Gypframe GA6 Splayed Angle


Acoustically enhanced vertical stud, designed to Steel angle providing framing stability and
receive fixing of board. board support.

Gypframe GWR2 Nogging Channel (43mm framing) Gypframe 99 FC 50 Fixing Channel


Nogging located mid-height between A versatile metal fixing channel used to support
Gypframe 43 AS 50 AcouStuds at 900mm centres to medium weight fixtures on walls.
Partitions

provide stability.

Gypframe GWR3 floor & Ceiling Channel Gypframe Service Support Plate
Floor and ceiling channels for retaining the vertical For installation of 18mm plywood within
C04

Gypframe 43 AS 50 AcouStuds at floor and ceiling a partition cavity to support medium to


junctions and around openings. heavyweight fixtures.

Gypframe Folded Edge Standard Floor & Ceiling


Channels (72 FEC 50)
Standard floor and ceiling channels for retaining the
vertical Gypframe 70 AS 50 AcouStuds at floor and
ceiling junctions and around openings.

Board products ( Refer to C10. S03. P02 for details)

Gyproc SoundBloc rapid1


Gypsum plasterboard in narrow width with a
high density core for enhanced sound insulation
performance.

1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

Fixing products ( Refer to C10. S04. P02 for details)

British Gypsum Drywall Screws British Gypsum Wafer Head Drywall Screws
Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws
for fixing board to metal framing less than for fixing metal to metal framing less than
0.8mm thick. 0.8mm thick.

Plasterboard accessories ( Refer to C10. S05. P02 for details)

Gyproc Sealant Gyproc edge and angle beads


Used to seal air paths for optimum sound Protecting and enhancing board edges and corners
insulation.

Gyproc Jointing Materials Gyproc Joint Tape


Jointing compounds, ready mixes and adhesives A paper tape designed for reinforcement of flat
for reinforcement and finishing of board joints. joints or internal angles.
Primers and sealers for treatment of boards for
pre-decoration.

C04. S10. P09 british-gypsum.com


GypWall rapid dB Plus
GypWall rapid dB Plus system components (continued)

Finishing products ( Refer to C10. S06. P02 for details)

Thistle MultiFinish ThistlePro DuraFinish


To provide a plaster skim finish on most common To provide a plaster skim finish and provide up to
backgrounds including undercoat plasters and 60% tougher resistance to accidental damage.
plasterboard. Can provide enhanced acoustic
performance.

Thistle BoardFinish ThistlePro PureFinish


To provide a plaster skim finish to To provide a plaster skim finish with
Gyproc plasterboards. ACTIVair technology. Used to finish most

Partitions
common backgrounds including undercoat plasters
and plasterboard. For more information refer to
C02. S01. P49.

C04
Thistle SprayFinish ThistlePro Magnetic
To provide a plaster skim finish by spray or hand To provide a plaster skim finish that provides an
application, ideal for medium to large projects. attraction to magnets used to finish a wide range
of backgrounds, including undercoat plasters and
plasterboard.

Thistle ProTape FT50 Thistle ProTape FT100


Self-adhesive 48mm wide glass fibre mesh tape. Self-adhesive 100mm wide glass fibre mesh tape.

Insulation products ( Refer to C10. S09. P02 for details)

Isover Acoustic Partition Roll (APR 1200)


Glass mineral wool for enhanced acoustic
performance.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S10. P10


GypWall rapid dB Plus system installation overview
GypWall rapid dB Plus

This is intended to be a basic description of how the system is installed.


For installation guidance refer to the British Gypsum Site Book.
Partitions

Gypframe Floor & Ceiling Channels are Gypframe Floor & Ceiling Channels are The perimeter of the partition is sealed on
suitably fixed to the floor and soffit. suitably fixed to abutments to form the both sides with Gyproc Sealant.
perimeter framework.
C04

Gypframe AcouStuds can be friction-fitted or Gypframe AcouStuds can be friction- Where Gypframe stud framing is installed at
vertically at 450mm centres to form the fitted vertically at 900mm centres to form 900mm centres, Gypframe GWR2 Nogging
framework, the framework. Channels are located horizontally between
each pair of studs at mid-height. Additional
framing is installed as required to support
heavy fixtures.

Isover Acoustic Partition Roll (APR 1200) Gyproc SoundBloc rapid boards are
can also be added to the partition cavity for screw-fixed to all framing members with
increased acoustic performance. British Gypsum Drywall Screws to form
the lining.

Additional information
For full installation details, refer to the
British Gypsum Site Book, available to
download from british-gypsum.com

C04. S10. P11 british-gypsum.com


GypWall rapid dB Plus
Partitions
C04

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S10. P12


Non-loadbearing timber stud

Non-loadbearing timber stud


Traditional stud partitions
Partitions
C04
Non-loadbearing timber stud
Non-loadbearing timber stud
Timber stud partitions provide basic space
30 120
division where speed of installation is mins

considered to be a lower priority. A wide range


of performances are available depending upon
the specification of British Gypsum linings, 34 63
Rw dB
Gypframe metal components and Isover
insulation.

Partitions
Key benefits System can be skim
finished with
ThistlePro PureFinish.
— High levels of acoustic performance are

C04
Refer to C02. S01. P49

achievable through the use of a range of


upgrades to the basic timber framework
including Gypframe RB1 Resilient Bar,
Gyproc SoundBloc and Isover Acoustic
Partition Roll (APR 1200)
— Can achieve up to 2 hours fire resistance
through the use of Gyproc FireLine
plasterboard

You may also be interested in...


GypWall quiet
If you’re looking for solutions with a higher level of acoustic and fire performance for use as a
separating wall in a residential building, or other more onerous situations
Refer to C04. S07. P02 – GypWall quiet.

If you’re looking for a Duty Rating in accordance with BS 5234: Part 2: 1992
Refer to C04. S01. P03 – Partitions performance matrix.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S11. P02


Non-loadbearing timber stud performance
Non-loadbearing timber stud

For details of when


to specify fire
63mm and 75mm timber stud partitions resistance using EN
Refer to C02. S01. P05
Table 1a — Solutions to satisfy the requirements of BS EN 1364-1 (Non-loadbearing)

1 2 3

One layer of board each side of timber Two layers of board each side of timber Remedial treatment on one side
studs at 600mm centres. Insulation and studs at 600mm centres. Insulation and of existing plasterboard partition
linings as in table. linings as in table. (minimum 1 x 12.5mm plasterboard
Partitions

each side of 75mm x 38mm studs at


600mm centres) using 50mm x 50mm
timber battens at 600mm centres,
50mm Isover Acoustic Partition Roll
(APR 1200) between the studs with
Gypframe RB1 Resilient Bar at 600mm
C04

centres (fixed horizontally).


Linings as in table.

Detail Partition Board type Lining Stud Sound insulation RwdB System
thickness thickness size No insulation With insulation reference
mm mm mm1

30 minutes fire resistance

1 88 Gyproc SoundBloc 1 x 12.5 63 x 38 - 402 A026009

1 93 Gyproc SoundBloc 1 x 15 63 x 38 40 - A026008

1 93 Gyproc WallBoard 1 x 15 63 x 38 - 402 A026010

1 105 Gyproc WallBoard 1 x 15 75 x 38 37 402 A026002/6

1 105 Gyproc SoundBloc 1 x 15 75 x 38 40 43 2


A026014/17

60 minutes fire resistance

2 115 Glasroc F multiboard 2 x 10 75 x 38 38 - G106004

2 125 Gyproc FireLine 2 x 12.5 75 x 38 38 42 2


A026028/9

3 196 Gyproc SoundBloc 2 x 15 75 x 38 - 52 A05402

90 minutes fire resistance

2 125 Glasroc F multiboard 2 x 12.5 75 x 38 37 - G106005

2 135 Gyproc FireLine 2 x 15 75 x 38 38 42 2


A026030/1

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Stud sizes quoted are minimum.
2
25mm Isover Acoustic Partition Roll (APR 1200) insulation.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked
with British Gypsum.

To establish the maximum cold state height for the partition refer to the relevant structural timber standards or a suitably qualified Structural Engineer.
In addition, for EN fire resistance the maximum height must not exceed the tested height (usually 3000mm).

C04. S11. P03 british-gypsum.com


Non-loadbearing timber stud performance (continued)

Non-loadbearing timber stud


For details of when
to specify fire
63mm, 75mm and 100mm timber stud partitions resistance using BS
Refer to C02. S01. P05
Table 1b — Solutions to satisfy requirements of BS 476: Part 22: 1987 (Non-loadbearing)

1 2 3 4

One layer of board each side of timber Two layers of board each side of timber Remedial treatment on one side One layer of board each side of timber
studs at 600mm centres. Insulation and studs at 600mm centres. Insulation and of existing plasterboard partition studs at 600mm centres and 65mm

Partitions
linings as in table. linings as in table. (minimum 1 x 12.5mm plasterboard Isover Acoustic Partition Roll (APR 1200)
each side of 75mm x 38mm studs at in the cavity. Linings as in table.
600mm centres) using 50mm x 50mm
timber battens at 600mm centres,
50mm Isover Acoustic Partition Roll
(APR 1200) between the studs with
Gypframe RB1 Resilient Bar at 600mm

C04
centres (fixed horizontally).
Linings as in table.

Detail Partition Board type Lining Stud Sound insulation RwdB System
thickness thickness size No insulation With insulation reference
mm mm mm1

30 minutes fire resistance

1 88 Gyproc SoundBloc 1 x 12.5 63 x 38 - 402 A026009

4 88 Gyproc WallBoard 1 x 12.5 63 x 38 - 41 A026012

1 93 Gyproc SoundBloc 1 x 15 63 x 38 40 - A026008

1 93 Gyproc WallBoard 1 x 15 63 x 38 - 40 2
A026010

1 100 Gyproc WallBoard 1 x 12.5 75 x 38 35 362 A0260013/0053

1 100 Gyproc SoundBloc 1 x 12.5 75 x 38 38 402 A0260113/016

1 105 Gyproc SoundBloc 1 x 15 75 x 38 40 43 2


A026014/017

60 minutes fire resistance

1 100 Glasroc F multiboard 1 x 12.5 75 x 50 34 - G106003

2 115 Glasroc F multiboard 2 x 10 75 x 50 38 - G106004

2 125 Gyproc WallBoard 2 x 12.5 75 x 38 38 42 2


A0260033/0073

2 125 Gyproc SoundBloc 2 x 12.5 75 x 38 44 462 A0260153/0183

3 196 Gyproc SoundBloc 2 x 15 75 x 38 - 52 A05402

90 minutes fire resistance

2 125 Glasroc F multiboard 2 x 12.5 75 x 38 37 - G106005

120 minutes fire resistance

2 160 Gyproc FireLine 2 x 15 100 x 50 41 - A026025

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Stud sizes quoted are minimum.
2
25mm Isover Acoustic Partition Roll (APR 1200) insulation.
3
Specification based on BR 128 only for use in Scotland, please refer to Building standards technical handbook 2019 Section 2.

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked
with British Gypsum.

To establish the maximum cold state height for the partition refer to the relevant structural timber standards or a suitably qualified Structural Engineer.
In addition, for EN fire resistance the maximum height must not exceed the tested height (usually 3000mm).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S11. P04


Non-loadbearing timber stud performance (continued)
Non-loadbearing timber stud

For details of when


to specify fire
75mm and 89mm timber stud walls resistance using EN
Refer to C02. S01. P05
Table 2a — Solutions to satisfy the requirements of BS EN 1364-1 (Non-loadbearing)

1 2 3

Two separate timber frames spaced Two layers of board each side of 75mm Two layers of board each side of 75mm
50mm apart, consisting of 89mm x x 38mm timber studs at 600mm centres x 38mm timber studs at 600mm centres
38mm timber studs at 600mm centres with Gypframe RB1 Resilient Bars fixed with Gypframe RB1 Resilient Bars fixed
Partitions

with noggings. Two layers of board each horizontally to one side at 600mm horizontally to both sides at 600mm
side. 100mm Isover Acoustic Partition centres. 50mm Isover Acoustic Partition centres. 50mm Isover Acoustic Partition
Roll (APR 1200) between the studs on Roll (APR 1200) in the cavity. Roll (APR 1200) in the cavity.
one side. Linings as in table. Linings as in table. Linings as in table.
C04

Detail Partition Board type Lining Stud Sound insulation System reference
thickness thickness size Rw (Rw+ Ctr)
mm mm mm dB

60 minutes fire resistance

2 141 Gyproc SoundBloc 2 x 12.5 75 x 38 56 (48) A046005

3 157 Gyproc SoundBloc 2 x 12.5 75 x 38 59 (51) A046006

1 293 Gyproc Plank + Gyproc FireLine 1 x 19 + 1 x 12.5 89 x 38 63 (51) A036003

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked
with British Gypsum.

To establish the maximum cold state height for the partition refer to the relevant structural timber standards or a suitably qualified Structural Engineer.
In addition, for EN fire resistance the maximum height must not exceed the tested height (usually 3000mm).

C04. S11. P05 british-gypsum.com


Non-loadbearing timber stud performance (continued)

Non-loadbearing timber stud


For details of when
to specify fire
75mm and 89mm timber stud walls resistance using BS
Refer to C02. S01. P05
Table 2b — Solutions to satisfy requirements of BS 476: Part 22: 1987 (Non-loadbearing)

1 2 3 4

Two separate timber frames spaced Two separate timber frames spaced Two layers of board each side of 75mm Two layers of board each side of 75mm
50mm apart, consisting of 89mm x 50mm apart, consisting of 89mm x x 38mm timber studs at 600mm centres x 38mm timber studs at 600mm centres
38mm timber studs at 600mm centres 38mm timber studs at 600mm centres with Gypframe RB1 Resilient Bars fixed with Gypframe RB1 Resilient Bars fixed
with noggings. Two layers of board each with noggings. Two layers of board each horizontally to one side at 600mm horizontally to both sides at 600mm

Partitions
side. 25mm Isover Acoustic Partition Roll side. 100mm Isover Spacesaver centres. 50mm Isover Acoustic Partition centres. 50mm Isover Acoustic Partition
(APR 1200) between the studs on one Ready-Cut between the studs on one Roll (APR 1200) in the cavity. Roll (APR 1200) in the cavity.
side. Linings as in table. side. Linings as in table. Linings as in table. Linings as in table.

Detail Partition Board type Lining Stud Sound insulation System reference

C04
thickness thickness size Rw (Rw+ Ctr)
mm mm mm dB

60 minutes fire resistance

3 141 Gyproc SoundBloc 2 x 12.5 75 x 38 56 (48) A046005

4 157 Gyproc SoundBloc 2 x 12.5 75 x 38 59 (51) A046006

2 290 Gyproc SoundBloc 1


2 x 15 89 x 38 61 (53) A036002

1 293 Gyproc Plank + Gyproc WallBoard 1 x 19 + 1 x 12.5 89 x 38 63 (51) A046022

90 minutes fire resistance

3 151 Gyproc SoundBloc 2 x 15 75 x 38 58 (51) A046007

4 167 Gyproc SoundBloc 2 x 15 75 x 38 60 (52) A046008

4 170 Gyproc Plank + Gyproc SoundBloc 1 x 19 + 1 x 12.5 75 x 38 60 (52) A046024

For further assistance in choosing the right solution for your project, try the White Book System Selector; an online tool that enables quick and
easy filtering by performance criteria. It provides system specific information downloads including BIM (Revit) objects. Go to british-gypsum.com

1
Test conducted to BS 476:Part 21: 1987 (loadbearing)

The fire resistance and sound insulation performances are for imperforate partitions, walls and ceilings incorporating boards with all joints taped and
filled, or skimmed according to British Gypsum’s recommendations. The quoted performances are achieved only if British Gypsum and Saint-Gobain Isover
components are used throughout, and the Company’s fixing recommendations are strictly observed. Any variation in the specifications should be checked
with British Gypsum.

To establish the maximum cold state height for the partition refer to the relevant structural timber standards or a suitably qualified Structural Engineer.
In addition, for EN fire resistance the maximum height must not exceed the tested height (usually 3000mm).

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S11. P06


Non-loadbearing timber stud design
Non-loadbearing timber stud

Planning – key factors Strength and robustness

The position of services and heavy fixtures should be Timber should be aligned and level, and should meet the
pre-determined and their installation planned into the frame requirements of BS 5268. The dimensions and assembly of timber
erection stage. If a plastered finish is specified, the thickness of the supports should be sufficient to allow positive fixing of plasterboard
door or glazing frame must allow for the thickness of the plaster finish. without bounce or undue deflection. When the above fixing
conditions cannot be met, a timber batten should be securely fixed
To minimise the risk of cracking at the plasterboard joints, to the side of the timber support to increase the bearing surface.
seasoned timber with a moisture content not exceeding that
recommended in BS 5268 should be used. The contractor should Where boards are fixed at maximum centres in adverse conditions,
ensure that timber supports are accurately spaced, aligned, the standard of lining can be affected. Adverse conditions can
and levelled. generally be described as conditions where high humidity occurs,
principally in the cold, damp, autumn / winter period. They also refer
Partitions

Cavity barriers to buildings under construction over this period, where both the
structure and wet applications, such as plastering and screeding,
Cavity barriers may be required to satisfy the requirements of
are subject to slow drying conditions (refer to table 3).
Building Regulations.

Refer to C06. S07. P02 – Cavity barriers.


Table 3 ­– Gyproc plasterboard or Glasroc F specialist board
C04

fixed direct to timber supports


Services
Board type Thickness Width Maximum
Penetrations mm mm recommended
Penetrations of fire resistant constructions for services need careful stud centres
mm
consideration to ensure that the integrity of the element is not
impaired and also that the services themselves do not act as the Gyproc WallBoard 12.5 900 450
mechanism of fire spread. 1200 600
15 900 450
Refer to C02. S01. P32 – Service installations.
1200 600

Electrical Gyproc FireLine 12.5 900 450

Electrical and other small service runs can be routed within the 1200 600
timber stud cavity. The installation of electrical services should be 15 900 450
carried out in accordance with BS 7671. Switch boxes and socket 1200 600
outlets can be supported from timber stud noggings. Gyproc Plank 19 600 600

Gyproc SoundBloc 12.5 1200 600


15 1200 600
Glasroc F multiboard 10 1200 600
12.5 1200 600

Partition junctions

At a ‘T’ junction, a ladder frame should be constructed between


studs to provide fixing points for the abutting partition, and to
support the lining (refer to construction detail 2). The horizontal
members of the frame should be at 600mm maximum centres.

Fixing to super-dried timber

It has been established by test that British Gypsum Drywall Screws


are the preferred solution for fixing to standard softwood or
superdried timber (approximately 12% moisture content).

Nail popping

Loosening of nails in timber can occur through timber shrinkage, or


as a result of fixing boards to misaligned or twisted framing.

To reduce the risks, boards should be fixed tight to framing


members, using British Gypsum Drywall Screws.

C04. S11. P07 british-gypsum.com


Non-loadbearing timber stud design (continued)

Non-loadbearing timber stud


Fixtures

Lightweight fixtures can be made directly to the partitions. Medium


weight, or heavyweight fixtures such as cisterns, radiators or wash
basins, can be made directly into the timber supports.

Additional studs or timber noggings should be installed


as appropriate.

Board finishing
Refer to C08. S01. P02 – Finishes.

Tiling

Partitions
Tiles up to 32kg/m2 can be applied to the surface of lightweight
partition systems.

Refer to C08. S04. P02 – Tiling.

C04
Important information
Ensure British Gypsum Drywall Screws
have a minimum of 25mm penetration
into the timber frame.

When using Gypframe RB1 Resilient Bar


specifications, screw length selection is
critical. Ensure the size of British Gypsum
Drywall Screws selected to fix the lining
to the Gypframe RB1 Resilient Bar do not
penetrate the timber frame and therefore
compromise the partition's acoustic
performance.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S11. P08


Non-loadbearing timber stud construction details
Non-loadbearing timber stud

1 2
2

4
4
3
2

4
1

7
Partitions

3
C04

'T' junction between studs

6
3

4
2

Head and base 'T' junction at stud

4 5

8
3
1

1 3

Internal / external corner Door jamb

1 Gyproc plasterboard 5 Bulk fill with Gyproc jointing materials (where gap exceeds 5mm)
2 Timber framing 6 Skirting
3 Isover insulation 7 Timber noggings at 600mm centres
4 Gyproc Sealant 8 Timber door frames and architrave

C04. S11. P09 british-gypsum.com


Non-loadbearing timber stud system components

Non-loadbearing timber stud


Gypframe metal components ( Refer to C10. S02. P11 for details) and framing

Gypframe RB1 Resilient Bar Timber (by others)


Acoustically engineered channel to separate board Typically 63mm to 100mm depth; 30mm to
fixing from the primary frame. Fixed horizontal to 50mm width.
face of studs.

Board products (continued) ( Refer to C10. S03. P02 for details)

Gyproc WallBoard Gyproc Plank


Standard gypsum plasterboard. Standard gypsum plasterboard located as an

Partitions
inner layer.

Gyproc WallBoard ten Gyproc DuraLine1

C04
Gypsum plasterboard with a controlled 10 kg/m² Gypsum plasterboard with fire resistant additives
weight for specific sound insulation performance and a high density core for enhanced sound
in accordance with Robust Details used within the insulation and impact resistance performance.
residential sector.

Gyproc Moisture Resistant Glasroc F multiboard


Gypsum plasterboard with moisture resistant Non-combustible glass-reinforced gypsum board.
additives in the core and special green lining paper
for easy recognition. Used as outer layer.

Gyproc FireLine1 Glasroc H tilebacker


Gypsum plasterboard with fire resistant additives. Non-combustible glass-reinforced gypsum board
with a water resistant pre-primed acrylic coating
to receive tiling.

Gyproc SoundBloc1
Gypsum plasterboard with a high density core for
enhanced sound insulation performance.

1
Also available in a Moisture Resistant (mr) version. mr boards are specified in intermittent wet use areas.

Fixing products ( Refer to C10. S04. P02 for details)

British Gypsum Drywall Screws British Gypsum Collated Drywall Screws


Corrosion resistant self-tapping steel screws Corrosion resistant self-tapping steel screws
for fixing board-to-timber and board-to-metal for fixing board-to-timber and board-to-metal
framing less than 0.8mm thick. framing less than 0.8mm thick.

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S11. P10


Non-loadbearing timber stud components (continued)
Non-loadbearing timber stud

Plasterboard accessories ( Refer to C10. S05. P02 for details)

Gyproc Jointing Material Gyproc edge and angle beads


Jointing compounds, ready mixes and adhesives for Protecting and enhancing board edges and corners
reinforcement and finishing of board joints. Primers
and sealers for treatment of boards for pre-decoration.

Gyproc Corner Tape Gyproc Sealant


A paper tape bonded to two corrosion resistant Used to seal air paths for optimum sound
steel strips. insulation.
Partitions

Gyproc Joint Tape Gyproc Habito Corners


A paper tape designed for reinforcement of flat A high strength, tapered co-polymer core offers
joints or internal angles. strong and uniform surface bonding for internal
and external angles in plasterboard constructions.
C04

Gyproc AquaBead
An easy to apply, water, activated adhesive corner
bead, for reinforcing external 90° angles in taped
and jointed plasterboard constructions.

Finishing products ( Refer to C10. S06. P02 for details)

Thistle MultiFinish ThistlePro DuraFinish


To provide a plaster skim finish on most common To provide a plaster skim finish and provide up to
backgrounds including undercoat plasters and 60% tougher resistance to accidental damage.
plasterboard. Can provide enhanced acoustic
performance.

Thistle BoardFinish ThistlePro PureFinish


To provide a plaster skim finish to To provide a plaster skim finish with
Gyproc plasterboards. ACTIVair technology. Used to finish most
common backgrounds including undercoat plasters
and plasterboard. For more information refer to
C02. S01.P49

Thistle SprayFinish Thistle ProTape FT50


To provide a plaster skim finish by spray or hand Self-adhesive 48mm wide glass fibre mesh tape.
application, ideal for medium to large projects.

Plaster accessories Thistle ProTape FT100


Designed for the reinforcement and finishing of Self-adhesive 100mm wide glass fibre mesh tape.
board joints before plaster skimming.

Decorative products ( Refer to C10. S07. P02 for details)

Gyproc Styletrims
Primed, pre-formed aluminium trims for design
effects with plasterboard.

Insulation products ( Refer to C10. S09. P02 for details)

Isover Acoustic Partition Roll (APR 1200)


Glass mineral wool for enhanced acoustic and
thermal performance.

C04. S11. P11 british-gypsum.com


Non-loadbearing timber stud installation overview

Non-loadbearing timber stud


This is intended to be a basic description of how the system is built.
For detailed installation guidance refer to the British Gypsum Site Book.

Partitions
Timber framing is fixed to the perimeter, Door openings are formed by fixing full M&E services can be located within the
abutments, and to frame any openings, height timber studs to each side, together partition cavity before the partition has
using suitable fixings. Timber studs are with a timber head piece. Door casings are been boarded. Timber noggings are fixed
fixed at specified centres. then fixed to the timber ground. Additional to support recessed switch boxes / socket

C04
framing is installed as required to support outlets.
heavy fixtures.

Where Gypframe RB1 Resilient Bars are Isover insulation can also be added to the The perimeter of the partition is sealed on
required, these are fixed horizontally to partition cavity for increased acoustic both sides with Gyproc Sealant.
the timber studs to one or both sides as performance.
specified.

Gyproc plasterboards are screw-fixed to all Horizontal board joints are backed with
timber supports, or to the Gypframe RB1 timber noggings or Gypframe RB1 Resilient
Resilient Bars with British Gypsum Drywall Bars as required.
Screws.

The correct length of fixings must be used when installing the


Gyproc board to the Gypframe RB1 Resiliant Bars to ensure that the
acoustic performance is not compromised. Additional information
For full installation details, refer to the
British Gypsum Site Book, available to
download from british-gypsum.com

0115 945 6123 bgtechnical.enquiries@bpb.com C04. S11. P12


C04 Partitions Non-loadbearing timber stud

C04. S11. P13


british-gypsum.com

You might also like