Preparatory Step (1.1) Critical Action


Purpose:

a. To allow fecal material to drain freely from the ostomy appliance.

b. To prevent leaking and skin breakdown around the stoma.

.‫ ﻟﻠﺴﻤﺎح ﻟﻠﻤﻮاد اﻟﺒﺮازﯾﺔ ﺑﺎﻟﺘﺼﺮﯾﻒ ﺑﺤﺮﯾﺔ ﻣﻦ ﺟﮭﺎز اﻟﻔﻐﺮة‬.‫أ‬

‫ ﻟﻤﻨﻊ اﻟﺘﺴﺮب وﺗﻜﺴﺮ اﻟﺠﻠﺪ ﺣﻮل اﻟﺜﻐﺮة‬.‫ب‬

Preparatory Step (1.2) Critical Action

Equipment:

• A new pouch (a 1-piece system, or 2-piece system that has a wafer)


• Basin with warm water
• Skin cleanser/soap, towel, washcloth
• Silicone-based adhesive remover •
• Gauze squares
• Washcloth or cotton balls
• Skin protectant such as Skin Prep
• One-piece/ Two-piece ostomy appliance
• Closure/ Pouch clip
• Stoma measuring guide
• Graduated container
• bedpan
• Ostomy belt (optional)
• Disposable gloves
• Pen or pencil
• Small plastic trash bag
• Waterproof disposable pad
• Additional PPE, as indicated
‫اﻷدوات ‪:‬‬
‫• ﻛﯿﺲ ﺟﺪﯾﺪ )ﻧﻈﺎم ﻣﻦ ﻗﻄﻌﺔ واﺣﺪة أو ﻧﻈﺎم ﻣﻦ ﻗﻄﻌﺘﯿﻦ ﺑﮫ رﻗﺎﻗﺔ(‬
‫• ﺣﻮض ﺑﻤﺎء داﻓﺊ‬
‫• ﻣﻨﻈﻒ ﻟﻠﺠﻠﺪ ‪ /‬ﺻﺎﺑﻮن ‪ ،‬ﻣﻨﺸﻔﺔ ‪ ،‬ﻗﻤﺎﺷﺔ‬
‫• ﻣﺰﯾﻞ ﻻﺻﻖ ﻗﺎﺋﻢ ﻋﻠﻰ اﻟﺴﯿﻠﯿﻜﻮن •‬
‫• ﻣﺮﺑﻌﺎت اﻟﺸﺎش‬
‫• ﻣﻨﺸﻔﺔ أو ﻛﺮات ﻗﻄﻨﯿﺔ‬
‫• واﻗﻲ ﻟﻠﺒﺸﺮة‬
‫• ﺟﮭﺎز ﻓﻐﺮ ﻣﻦ ﻗﻄﻌﺔ واﺣﺪة ‪ /‬ﻗﻄﻌﺘﯿﻦ‬
‫• اﻹﻏﻼق ‪ /‬اﻟﺤﻘﯿﺒﺔ ﻛﻠﯿﺐ‬
‫• دﻟﯿﻞ ﻗﯿﺎس اﻟﻔﻐﺮة‬
‫• ﺣﺎوﯾﺔ ﻣﺘﺪرﺟﺔ‬
‫• اﻟﺴﺮﯾﺮ‬
‫• ﺣﺰام )اﺧﺘﯿﺎري(‬
‫• ﻗﻔﺎزات ﯾﻤﻜﻦ اﻟﺘﺨﻠﺺ ﻣﻨﮭﺎ‬
‫• ﻗﻠﻢ أو ﻗﻠﻢ رﺻﺎص‬
‫• ﻛﯿﺲ ﻗﻤﺎﻣﺔ ﺑﻼﺳﺘﯿﻚ ﺻﻐﯿﺮ‬
‫• وﺳﺎدة ﻣﻀﺎدة ﻟﻠﻤﺎء ﯾﻤﻜﻦ اﻟﺘﺨﻠﺺ ﻣﻨﮭﺎ‬
‫• ﻣﻌﺪات اﻟﺤﻤﺎﯾﺔ اﻟﺸﺨﺼﯿﺔ اﻹﺿﺎﻓﯿﺔ ‪ ،‬ﻛﻤﺎ ھﻮ ﻣﺤﺪد‬

‫‪Page 82‬‬
Preparatory Step (2.1) Critical Action
Assessment:
1. Assess current condition of ostomy appliance and stoma (color, size and shape, if bag is clear).
2. Determine the patient’s knowledge and complaints about ostomy care.
3. Assess the skin surrounding the stoma (bleeding, swelling, irritation).
4. Assess the amount, type, color, consistency, and odor of stool from ostomy.
5. The client’s and family members’ learning needs regarding the ostomy and self-care.
6. The client’s emotional status, especially strategies used to cope with the ostomy.
7. Assess the fullness of the pouch.
: ‫( ﺗﻘﯿﯿﻢ اﻟﻌﻤﻞ‬2.1) ‫اﻟﺨﻄﻮة اﻟﺘﺤﻀﯿﺮﯾﺔ‬
.(‫ إذا ﻛﺎن اﻟﻜﯿﺲ ﻧﻈﯿﻔًﺎ‬، ‫ ﺗﻘﯿﯿﻢ اﻟﺤﺎﻟﺔ اﻟﺤﺎﻟﯿﺔ ﻟﺠﮭﺎز اﻟﻔﻐﺮة واﻟﻔُْﻐﺮة )اﻟﻠﻮن واﻟﺤﺠﻢ واﻟﺸﻜﻞ‬.1
.‫ ﺗﺤﺪﯾﺪ ﻣﻌﺮﻓﺔ اﻟﻤﺮﯾﺾ وﺷﻜﺎوي ﺣﻮل رﻋﺎﯾﺔ اﻟﻔﻐﺮ‬.2
.(‫ ﺗﮭﯿﺞ‬، ‫ ﺗﻮرم‬، ‫ ﻗﻢ ﺑﺘﻘﯿﯿﻢ اﻟﺠﻠﺪ اﻟﻤﺤﯿﻂ ﺑﺎﻟﻔﺘﺤﺔ )ﻧﺰﯾﻒ‬.3
.‫ ﻗﻢ ﺑﺘﻘﯿﯿﻢ ﻛﻤﯿﺔ وﻧﻮع وﻟﻮن واﺗﺴﺎق وراﺋﺤﺔ اﻟﺒﺮاز ﻣﻦ اﻟﻔﻐﺮة‬.4
.‫ اﺣﺘﯿﺎﺟﺎت اﻟﺘﻌﻠﻢ ﻟﻠﻌﻤﯿﻞ وأﻓﺮاد اﻷﺳﺮة ﻓﯿﻤﺎ ﯾﺘﻌﻠﻖ ﺑﺎﻟﻔﻐﺮ واﻟﺮﻋﺎﯾﺔ اﻟﺬاﺗﯿﺔ‬.5
.‫ وﺧﺎﺻﺔ اﻻﺳﺘﺮاﺗﯿﺠﯿﺎت اﻟﻤﺴﺘﺨﺪﻣﺔ ﻟﻠﺘﻌﺎﻣﻞ ﻣﻊ اﻟﻔﻐﺮ‬، ‫ اﻟﺤﺎﻟﺔ اﻟﻌﺎطﻔﯿﺔ ﻟﻠﻌﻤﯿﻞ‬.6
.‫ ﺗﻘﯿﯿﻢ اﻣﺘﻼء اﻟﺤﻘﯿﺒﺔ‬.7

Preparatory Step (2.2)


Nursing Diagnosis:
• Risk for Impaired Skin Integrity ‫ • ﺧﻄﺮ ﺣﺪوث ﺧﻠﻞ ﻓﻲ ﺳﻼﻣﺔ اﻟﺠﻠﺪ‬Constipation ‫إﻣﺴﺎك‬
• Ineffective Coping ‫• اﻟﺘﺄﻗﻠﻢ ﻏﯿﺮ اﻟﻔﻌﺎل‬ Disturbed Body Image ‫ﺻﻮرة اﻟﺠﺴﻢ اﻟﻤﻨﺰﻋﺠﺔ‬
• Deficient Knowledge ‫ﻧﻘﺺ اﻟﻤﻌﺮﻓﮫ‬ Diarrhea ‫اﻻﺳﮭﺎل‬

Page 83
IMPLEMENTATION

Critical Action

Step Action Rationale


Yes No

1. Follow Standard Protocol: This ensures that the correct intervention is


performed on the correct patient.
Verify or Check Doctor’s Order. ‫ھﺬا ﯾﻀﻤﻦ إﺟﺮاء اﻟﺘﺪﺧﻞ اﻟﺼﺤﯿﺢ ﻋﻠﻰ اﻟﻤﺮﯾﺾ اﻟﺼﺤﯿﺢ‬
Identifying the patient ensures the right patient
Identify the patient.
receives the intervention and helpsrelive
Introduce yourself and explain the anxiety.
procedure. ‫ﯾﻀﻤﻦ اﻟﺘﻌﺮف ﻋﻠﻰ اﻟﻤﺮﯾﺾ أن ﯾﺘﻠﻘﻰ اﻟﻤﺮﯾﺾ اﻟﻤﻨﺎﺳﺐ‬
‫اﻟﺘﺪﺧﻞ وﯾﺴﺎﻋﺪ ﻓﻲ ﺗﺨﻔﯿﻒ اﻟﻘﻠﻖ‬
Provide privacy and position comfortably. This ensures the patient’s privacy.
‫ھﺬا ﯾﻀﻤﻦ ﺧﺼﻮﺻﯿﺔ اﻟﻤﺮﯾﺾ‬
Perform hand hygiene and put on PPE if
indicated. Hand hygiene and PPE prevent the spread of
.‫ اﻟﺘﻌﺮف ﻋﻠﻰ اﻟﻤﺮﯾﺾ‬.‫ﺗﺤﻘﻖ أو ﺗﺤﻘﻖ ﻣﻦ طﻠﺐ اﻟﻄﺒﯿﺐ‬ microorganisms. PPE is required based on
.‫ﻗﺪم ﻧﻔﺴﻚ واﺷﺮح اﻹﺟﺮاء‬ Transmission Precautions.
.‫ﺗﻮﻓﯿﺮ اﻟﺨﺼﻮﺻﯿﺔ واﻟﻤﻮﻗﻒ ﺑﺸﻜﻞ ﻣﺮﯾﺢ‬
‫ﺗﻤﻨﻊ ﻧﻈﺎﻓﺔ اﻟﯿﺪﯾﻦ وﻣﻌﺪات اﻟﺤﻤﺎﯾﺔ اﻟﺸﺨﺼﯿﺔ اﻧﺘﺸﺎر‬
‫ﻗﻢ ﺑﺘﻨﻈﯿﻒ اﻟﯿﺪﯾﻦ وارﺗﺪ ﻣﻌﺪات اﻟﻮﻗﺎﯾﺔ‬ ‫ ﻣﻄﻠﻮب ﻣﻌﺪات اﻟﺤﻤﺎﯾﺔ اﻟﺸﺨﺼﯿﺔ‬.‫اﻟﻜﺎﺋﻨﺎت اﻟﺪﻗﯿﻘﺔ‬
‫اﻟﺸﺨﺼﯿﺔ إذا ﻟﺰم اﻷﻣﺮ‬ ‫ﺑﻨﺎًء ﻋﻠﻰ اﺣﺘﯿﺎطﺎت اﻟﻨﻘﻞ‬

Page 84
2. Bring necessary equipment to the Arranging items nearby is convenient, saves time,
bedside stand or overbed table. and avoids unnecessary stretching andtwisting of
‫أﺣﻀﺮ اﻟﻤﻌﺪات اﻟﻼزﻣﺔ إﻟﻰ ﺣﺎﻣﻞ اﻟﺴﺮﯾﺮ أو طﺎوﻟﺔ‬ muscles on the part of the nurse.
.‫اﻟﺴﺮﯾﺮ‬ ‫ﯾﻌﺪ ﺗﺮﺗﯿﺐ اﻟﻌﻨﺎﺻﺮ اﻟﻘﺮﯾﺒﺔ أﻣًﺮا ﻣﺮﯾًﺤﺎ وﯾﻮﻓﺮ اﻟﻮﻗﺖ‬
‫وﯾﺘﺠﻨﺐ اﻟﺸﺪ واﻟﺘﻮاء ﻏﯿﺮ اﻟﻀﺮوري ﻟﻠﻌﻀﻼت ﻣﻦ ﺟﺎﻧﺐ‬
.‫اﻟﻤﻤﺮﺿﺔ‬

3. Assist patient to a comfortable sitting orlying Proper positioning will allow the patient to view
position in bed or a standing or sitting the procedure in preparation to learn to perform
position in the bathroom. it independently. Lying flat or sitting upright
facilitates smooth applicationof the appliance.
‫ﺳﯿﺴﻤﺢ اﻟﻮﺿﻊ اﻟﻤﻨﺎﺳﺐ ﻟﻠﻤﺮﯾﺾ ﺑﻤﺸﺎھﺪة اﻹﺟﺮاء اﺳﺘﻌﺪادًا‬
‫ اﻻﺳﺘﻠﻘﺎء أو اﻟﺠﻠﻮس ﻓﻲ وﺿﻊ‬.‫ﻟﺘﻌﻠﻢ ﻛﯿﻔﯿﺔ ﺗﻨﻔﯿﺬه ﺑﺸﻜﻞ ﻣﺴﺘﻘﻞ‬
.‫ﻣﺴﺘﻘﯿﻢ ﯾﺴﮭﻞ اﻟﺘﻄﺒﯿﻖ اﻟﺴﻠﺲ ﻟﻠﺠﮭﺎز‬

‫ﺳﺎﻋﺪ اﻟﻤﺮﯾﺾ ﻋﻠﻰ اﻟﺠﻠﻮس أو اﻟﺠﻠﻮس اﻟﻤﺮﯾﺢ ﻓﻲ‬


.‫اﻟﺴﺮﯾﺮ أو اﻟﻮﻗﻮف أو اﻟﺠﻠﻮس ﻓﻲ اﻟﺤﻤﺎم‬
4. EMPTYING AN APPLIANCE:
:‫إﻓﺮاغ اﻟﺠﮭﺎز‬
Put on disposable gloves. Remove clampandfold Gloves prevent contact with blood, body fluids,
end of pouch upward like a cuff. and microorganisms. Creating a cuff before
emptying prevents additional soilingand odor.
‫ ﻗﻢ ﺑﺈزاﻟﺔ‬.‫ارﺗِﺪ اﻟﻘﻔﺎزات اﻟﺘﻲ ﺗﺴﺘﺨﺪم ﻟﻤﺮة واﺣﺪة‬
‫ﺗﻤﻨﻊ اﻟﻘﻔﺎزات ﻣﻼﻣﺴﺔ اﻟﺪم وﺳﻮاﺋﻞ اﻟﺠﺴﻢ واﻟﻜﺎﺋﻨﺎت‬
‫اﻟﻄﺮف اﻟﻤﻄﻮي ﻟﻠﺤﻘﯿﺒﺔ ﻷﻋﻠﻰ ﻣﺜﻞ اﻟﻜﻔﺔ‬
‫ ﯾﻤﻨﻊ ﺗﻜﻮﯾﻦ اﻟﻤﻄﻮق ﻗﺒﻞ ﺗﻔﺮﯾﻐﮫ اﻟﻤﺰﯾﺪ‬.‫اﻟﺤﯿﺔ اﻟﺪﻗﯿﻘﺔ‬
.‫ﻣﻦ اﻻﺗﺴﺎخ واﻟﺮاﺋﺤﺔ‬
5. Empty contents into bedpan, toilet, or Appliances do not need rinsing because
measuring device. rinsing may reduce appliance’s odor barrier.
‫ﻗﻢ ﺑﺈﻓﺮاغ اﻟﻤﺤﺘﻮﯾﺎت ﻓﻲ ﻏﻄﺎء اﻟﺴﺮﯾﺮ أو‬
Drying the lower section of the appliance
.‫اﻟﻤﺮﺣﺎض أو ﺟﮭﺎز اﻟﻘﯿﺎس‬
rem oves any additional fecal m aterial, thus
decreasing odor problems.
‫ﻻ ﺗﺤﺘﺎج اﻷﺟﮭﺰة إﻟﻰ اﻟﺸﻄﻒ ﻷن اﻟﺸﻄﻒ ﻗﺪ ﯾﻘﻠﻞ ﻣﻦ ﺣﺎﺟﺰ‬
.‫اﻟﺮواﺋﺢ ﻓﻲ اﻟﺠﮭﺎز‬

‫ﯾﺆدي ﺗﺠﻔﯿﻒ اﻟﺠﺰء اﻟﺴﻔﻠﻲ ﻣﻦ اﻟﺠﮭﺎز إﻟﻰ إزاﻟﺔ‬


.‫ وﺑﺎﻟﺘﺎﻟﻲ ﺗﻘﻠﯿﻞ ﻣﺸﺎﻛﻞ اﻟﺮاﺋﺤﺔ‬، ‫أي ﺑﺮاز إﺿﺎﻓﻲ‬
Wipe the lower 2 inches of the applianceor
pouch with toilet tissue

‫ ﺑﻮﺻﺔ ﻣﻦ اﻟﺠﮭﺎز أو‬2 ‫اﻣﺴﺢ اﻟﺠﺰء اﻟﺴﻔﻠﻲ‬


‫اﻟﺤﻘﯿﺒﺔ ﺑﻤﻨﺪﯾﻞ اﻟﻤﺮﺣﺎض‬

6. Uncuff edge of appliance or pouch and The edge of the appliance or pouch should
apply clip or clamp, or secure Velcro remain clean. The clamp secures closure. Hand
closure. Ensure the curve of the clamp hygiene deters spread of microorganisms.
follows the curve of the patient’s body. Ensures patient comfort.
Remove gloves. Assist patient to a ‫ اﻟﻤﺸﺒﻚ ﯾﺆﻣﻦ‬.‫ﯾﺠﺐ أن ﺗﻈﻞ ﺣﺎﻓﺔ اﻟﺠﮭﺎز أو اﻟﺤﻘﯿﺒﺔ ﻧﻈﯿﻔﺔ‬
comfortable position. .‫ ﺗﻤﻨﻊ ﻧﻈﺎﻓﺔ اﻟﯿﺪﯾﻦ اﻧﺘﺸﺎر اﻟﻜﺎﺋﻨﺎت اﻟﺤﯿﺔ اﻟﺪﻗﯿﻘﺔ‬.‫اﻹﻏﻼق‬
‫ﻗﻢ ﺑﻔﻚ ﺣﺎﻓﺔ اﻟﺠﮭﺎز أو اﻟﺤﻘﯿﺒﺔ وﻗﻢ ﺑﺘﻄﺒﯿﻖ‬ .‫ﯾﻀﻤﻦ راﺣﺔ اﻟﻤﺮﯾﺾ‬
.‫ أو إﻏﻼق اﻟﻔﯿﻠﻜﺮو ﺑﺈﺣﻜﺎم‬، ‫ﻣﺸﺒﻚ أو ﻣﺸﺒﻚ‬
‫ﺗﺄﻛﺪ ﻣﻦ أن ﻣﻨﺤﻨﻰ اﻟﻤﺸﺒﻚ ﯾﺘﺒﻊ ﻣﻨﺤﻨﻰ ﺟﺴﻢ‬
‫ ﻣﺴﺎﻋﺪة اﻟﻤﺮﯾﺾ‬.‫ اﻧﺰع اﻟﻘﻔﺎزات‬.‫اﻟﻤﺮﯾﺾ‬
.‫ﻓﻲ وﺿﻊ ﻣﺮﯾﺢ‬

7. If appliance is not to be changed, remove Removing PPE properly reduces the risk for
additional PPE, if used. Perform hand infection transmission and contamination ofother
‫ ﻓﻘﻢ ﺑﺈزاﻟﺔ ﻣﻌﺪات‬، ‫إذا ﻟﻢ ﯾﺘﻢ ﺗﻐﯿﯿﺮ اﻟﺠﮭﺎز‬ items. Hand hygiene prevents the spread of
.‫ إذا ﺗﻢ اﺳﺘﺨﺪاﻣﮭﺎ‬، ‫اﻟﺤﻤﺎﯾﺔ اﻟﺸﺨﺼﯿﺔ اﻹﺿﺎﻓﯿﺔ‬ microorganisms.
‫أداء اﻟﯿﺪ‬ ‫ﺗﻘﻠﻞ إزاﻟﺔ ﻣﻌﺪات اﻟﻮﻗﺎﯾﺔ اﻟﺸﺨﺼﯿﺔ ﺑﺸﻜﻞ ﺻﺤﯿﺢ ﻣﻦ‬
‫ ﺗﻤﻨﻊ‬.‫ﺧﻄﺮ اﻧﺘﻘﺎل اﻟﻌﺪوى وﺗﻠﻮث اﻟﻌﻨﺎﺻﺮ اﻷﺧﺮى‬
.‫ﻧﻈﺎﻓﺔ اﻟﯿﺪﯾﻦ اﻧﺘﺸﺎر اﻟﻜﺎﺋﻨﺎت اﻟﺪﻗﯿﻘﺔ‬

Page 86
hygiene.

8. CHANGING AN APPLIANCE:

Place a disposable pad on the work surface. Protects the bed surface from contamination.
Set up the wash basin with warmwater and the Organization of equipmentsfacilitates
rest of the supplies. Place a trash bag within performance of procedure.
reach.
‫ ﺗﻨﻈﯿﻢ اﻟﻤﻌﺪات‬.‫ﯾﺤﻤﻲ ﺳﻄﺢ اﻟﺴﺮﯾﺮ ﻣﻦ اﻟﺘﻠﻮث‬
:‫ﺗﻐﯿﯿﺮ اﻟﺠﮭﺎز‬
.‫ﯾﺴﮭﻞ أداء اﻹﺟﺮاء‬

‫ ﻗﻢ‬.‫ﺿﻊ ﺿﻤﺎدة ﯾﻤﻜﻦ اﻟﺘﺨﻠﺺ ﻣﻨﮭﺎ ﻋﻠﻰ ﺳﻄﺢ اﻟﻌﻤﻞ‬


.‫ﺑﺈﻋﺪاد ﺣﻮض اﻟﻐﺴﯿﻞ ﺑﺎﻟﻤﺎء اﻟﺪاﻓﺊ وﺑﻘﯿﺔ اﻟﻤﺴﺘﻠﺰﻣﺎت‬
.‫ﺿﻊ ﻛﯿﺲ ﻗﻤﺎﻣﺔ ﻓﻲ ﻣﺘﻨﺎول اﻟﯿﺪ‬

9. Put on clean gloves. Place waterproof pad Protects the bed linens and patient from moisture.
under the patient at the stoma site.Empty the Emptying the contents before removal prevents
appliance as described previously. accidental spillage of fecalmaterial.
‫ ﺿﻊ ﺿﻤﺎدة ﻣﻘﺎوﻣﺔ ﻟﻠﻤﺎء ﺗﺤﺖ‬.‫ارﺗِﺪ ﻗﻔﺎزات ﻧﻈﯿﻔﺔ‬ ‫ ﯾﺆدي ﺗﻔﺮﯾﻎ‬.‫ﯾﺤﻤﻲ أﻏﻄﯿﺔ اﻟﺴﺮﯾﺮ واﻟﻤﺮﯾﺾ ﻣﻦ اﻟﺮطﻮﺑﺔ‬
‫ وأﻓﺮغ اﻟﺠﮭﺎز ﻛﻤﺎ ھﻮ‬، ‫اﻟﻤﺮﯾﺾ ﻓﻲ ﻣﻮﻗﻊ اﻟﻔﻐﺮة‬ ‫اﻟﻤﺤﺘﻮﯾﺎت ﻗﺒﻞ اﻹزاﻟﺔ إﻟﻰ ﻣﻨﻊ اﻻﻧﺴﻜﺎب اﻟﻌﺮﺿﻲ ﻟﻠﻤﻮاد‬
.‫ﻣﻮﺻﻮف ﺳﺎﺑﻘًﺎ‬ .‫اﻟﺒﺮازﯾﺔ‬

Page 87
10. Gently remove pouch faceplate from skinby The seal between the surface of the faceplate and
pushing skin from appliance rather than the skin must be broken before the faceplate can
pulling appliance from skin. Start at the top of be removed. Harshhandling of the appliance can
the appliance, while keeping the abdominal damage the skin and impair the development of a
skin taut. Apply a silicone-based adhesive secureseal in the future. Silicone-based adhesive
remover by spraying or wiping with the remover allows for the rapid and painless
remover wipe. removal of adhesives and prevents skin stripping.
‫ﻗﻢ ﺑﺈزاﻟﺔ ﻟﻮﺣﺔ واﺟﮭﺔ اﻟﺤﻘﯿﺒﺔ ﺑﺮﻓﻖ ﻣﻦ اﻟﺠﻠﺪ ﻋﻦ‬ ‫ﯾﺠﺐ ﻛﺴﺮ اﻟﺨﺘﻢ ﺑﯿﻦ ﺳﻄﺢ اﻟﻠﻮﺣﺔ اﻷﻣﺎﻣﯿﺔ واﻟﺠﻠﺪ ﻗﺒﻞ‬
‫طﺮﯾﻖ دﻓﻊ اﻟﺠﻠﺪ ﻣﻦ اﻟﺠﮭﺎز ﺑﺪﻻً ﻣﻦ ﺳﺤﺐ اﻟﺠﮭﺎز ﻣﻦ‬ ‫ ﯾﻤﻜﻦ أن ﯾﺆدي اﻻﺳﺘﺨﺪام اﻟﻘﺎﺳﻲ‬.‫إزاﻟﺔ اﻟﻠﻮﺣﺔ اﻷﻣﺎﻣﯿﺔ‬
‫ ﻣﻊ اﻟﺤﻔﺎظ‬، ‫ اﺑﺪأ ﻣﻦ اﻟﺠﺰء اﻟﻌﻠﻮي ﻣﻦ اﻟﺠﮭﺎز‬.‫اﻟﺠﻠﺪ‬ ‫ﻟﻠﺠﮭﺎز إﻟﻰ إﺗﻼف اﻟﺠﻠﺪ وإﻋﺎﻗﺔ ﺗﻄﻮﯾﺮ ﺧﺘﻢ آﻣﻦ ﻓﻲ‬
‫ ﺿﻊ ﻣﺰﯾﻞ اﻟﻼﺻﻖ ذو‬.‫ﻋﻠﻰ ﺟﻠﺪ اﻟﺒﻄﻦ ﻣﺸﺪودًا‬ ‫ ﯾﺴﻤﺢ ﻣﺰﯾﻞ اﻟﻼﺻﻖ اﻟﻘﺎﺋﻢ ﻋﻠﻰ اﻟﺴﯿﻠﯿﻜﻮن‬.‫اﻟﻤﺴﺘﻘﺒﻞ‬
‫اﻷﺳﺎس اﻟﺴﯿﻠﯿﻜﻮﻧﻲ ﻋﻦ طﺮﯾﻖ اﻟﺮش أو اﻟﻤﺴﺢ ﺑﻤﺴﺤﺔ‬ ‫ﺑﺈزاﻟﺔ ﺳﺮﯾﻌﺔ وﻏﯿﺮ ﻣﺆﻟﻤﺔ ﻟﻠﻤﻮاد اﻟﻼﺻﻘﺔ وﯾﻤﻨﻊ ﺗﺠﺮﯾﺪ‬
.‫اﻟﻤﺰﯾﻞ‬ .‫اﻟﺠﻠﺪ‬

11. Place the appliance in the trash bag, if Thorough cleaning and airing of the appliance
disposable. If reusable, set aside to wash in reduce odor and deterioration of appliance. For
lukewarm soap and water and allow toair dry esthetic and infection-controlpurposes, discard
after the new appliance is in place. used appliances appropriately.
‫ إذا ﻛﺎن ﯾﻤﻜﻦ اﻟﺘﺨﻠﺺ‬، ‫ﺿﻊ اﻟﺠﮭﺎز ﻓﻲ ﻛﯿﺲ اﻟﻘﻤﺎﻣﺔ‬ ‫ﯾﺆدي اﻟﺘﻨﻈﯿﻒ واﻟﺘﮭﻮﯾﺔ اﻟﺸﺎﻣﻼن ﻟﻠﺠﮭﺎز إﻟﻰ ﺗﻘﻠﯿﻞ‬
ً ‫ اﺗﺮﻛﮫ ﺟﺎﻧﺒﺎ‬، ‫ إذا ﻛﺎن ﻗﺎﺑﻼً ﻹﻋﺎدة اﻻﺳﺘﺨﺪام‬.‫ﻣﻨﮫ‬ ‫ ﻟﻸﻏﺮاض اﻟﺘﺠﻤﯿﻠﯿﺔ‬.‫اﻟﺮاﺋﺤﺔ وﺗﺪھﻮر ﺣﺎﻟﺔ اﻟﺠﮭﺎز‬
‫ﻟﻐﺴﻠﮫ ﺑﺎﻟﻤﺎء واﻟﺼﺎﺑﻮن اﻟﻔﺎﺗﺮ واﺗﺮﻛﮫ ﯾﺠﻒ ﺑﻌﺪ وﺿﻊ‬ ‫ ﺗﺨﻠﺺ ﻣﻦ اﻷﺟﮭﺰة اﻟﻤﺴﺘﺨﺪﻣﺔ‬، ‫وﻣﻜﺎﻓﺤﺔ اﻟﻌﺪوى‬
.‫اﻟﺠﮭﺎز اﻟﺠﺪﯾﺪ ﻓﻲ ﻣﻜﺎﻧﮫ‬ .‫ﺑﺸﻜﻞ ﻣﻨﺎﺳﺐ‬

Page 88
12. Use toilet tissue to remove any excess stool Toilet tissue, used gently, will not damage the
from stoma. Cover stoma with gauze pad. stoma. The gauze absorbs any drainage from the
Clean skin around stoma with mild soap and stoma while the skin is being prepared. Cleaning
water or a cleansing agent and a washcloth. the skin removes excretions and old adhesive and
Remove all old adhesivefrom skin; use an skin protectant. Excretions or a buildup of other
adhesive remover, as necessary. Do not apply substances can irritate and damage the skin.
lotion to peristomal area. Lotion will prevent a tight adhesive seal.
.‫اﺳﺘﺨﺪم ﻣﻨﺎدﯾﻞ اﻟﺤﻤﺎم ﻹزاﻟﺔ أي ﺑﺮاز زاﺋﺪ ﻣﻦ اﻟﻔﻐﺮة‬ ‫ ﯾﻤﺘﺺ اﻟﺸﺎش‬.‫اﺳﺘﺨﺪام ﻣﻨﺎدﯾﻞ اﻟﺤﻤﺎم ﺑﺮﻓﻖ ﻟﻦ ﯾﺘﻠﻒ اﻟﻔﺘﺤﺔ‬
‫ ﻧﻈﻒ اﻟﺠﻠﺪ ﺣﻮل اﻟﺜﻐﺮة‬.‫ﺗﻐﻄﯿﺔ اﻟﻔﻐﺮة ﺑﻀﻤﺎدة ﺷﺎش‬ ‫ ﺗﻨﻈﯿﻒ اﻟﺠﻠﺪ‬.‫أي ﺗﺼﺮﯾﻒ ﻣﻦ اﻟﻔﻐﺮة أﺛﻨﺎء ﺗﺤﻀﯿﺮ اﻟﺠﻠﺪ‬
‫ إزاﻟﺔ‬.‫ﺑﺼﺎﺑﻮن ﺧﻔﯿﻒ وﻣﺎء أو ﻋﺎﻣﻞ ﻣﻨﻈﻒ وﻣﻨﺸﻔﺔ‬ ‫ ﯾﻤﻜﻦ‬.‫ﯾﺰﯾﻞ اﻹﻓﺮازات واﻟﻤﻮاد اﻟﻼﺻﻘﺔ اﻟﻘﺪﯾﻤﺔ وواﻗﻲ اﻟﺠﻠﺪ‬
‫ﺟﻤﯿﻊ اﻟﻤﻮاد اﻟﻼﺻﻘﺔ اﻟﻘﺪﯾﻤﺔ ﻣﻦ اﻟﺠﻠﺪ ؛ اﺳﺘﺨﺪم ﻣﺰﯾﻞ‬ ‫أن ﺗﺆدي اﻹﻓﺮازات أو ﺗﺮاﻛﻢ اﻟﻤﻮاد اﻷﺧﺮى إﻟﻰ ﺗﮭﯿﺞ اﻟﺠﻠﺪ‬
‫ ﻻ ﺗﻀﻊ اﻟﻤﺴﺘﺤﻀﺮ‬.‫ ﺣﺴﺐ اﻟﻀﺮورة‬، ‫اﻟﻤﻮاد اﻟﻼﺻﻘﺔ‬ .‫وإﺗﻼﻓﮫ‬
.‫ﻋﻠﻰ ﻣﻨﻄﻘﺔ اﻟﺘﻤﻌﺞ‬ .‫ﺳﻮف ﯾﻤﻨﻊ اﻟﻤﺴﺘﺤﻀﺮ ﺧﺘﻢ ﻻﺻﻖ ﻣﺤﻜﻢ‬

13. Gently pat area dry. Make sure skin around Careful drying prevents trauma to skin and
stoma is thoroughly dry. Assess stoma and stoma. Properly applied urinary collection device
condition of surrounding skin. protects skin integrity. Any change incolor and
‫ ﺗﺄﻛﺪ ﻣﻦ ﺟﻔﺎف اﻟﺠﻠﺪ ﺣﻮل‬.‫ﺟﻔﻒ اﻟﻤﻨﻄﻘﺔ ﺑﻠﻄﻒ‬ size of the stoma may indicate circulatory
.‫ ﺗﻘﯿﯿﻢ اﻟﻔﻐﺮة وﺣﺎﻟﺔ اﻟﺠﻠﺪ اﻟﻤﺤﯿﻂ‬.‫اﻟﺜﻐﺮة ﺗﻤﺎًﻣﺎ‬ problems.
.‫اﻟﺘﺠﻔﯿﻒ اﻟﺪﻗﯿﻖ ﯾﻤﻨﻊ اﻟﺼﺪﻣﺎت اﻟﺘﻲ ﺗﻠﺤﻖ ﺑﺎﻟﺠﻠﺪ واﻟﻔُْﻐﺮة‬
‫ﺟﮭﺎز ﺟﻤﻊ اﻟﺒﻮل اﻟﻤﻄﺒﻖ ﺑﺸﻜﻞ ﺻﺤﯿﺢ ﯾﺤﻤﻲ ﺳﻼﻣﺔ‬
‫ ﻗﺪ ﯾﺸﯿﺮ أي ﺗﻐﯿﯿﺮ ﻓﻲ ﻟﻮن وﺣﺠﻢ اﻟﻔﻐﺮة إﻟﻰ ﻣﺸﺎﻛﻞ‬.‫اﻟﺠﻠﺪ‬
.‫ﻓﻲ اﻟﺪورة اﻟﺪﻣﻮﯾﺔ‬

14. Apply skin protectant to a 2-inch (5 cm) The skin needs protection from the
radius around the stoma, and allow it to excoriating effect of the excretion and
2 ‫ﺿﻊ واﻗﻲ اﻟﺠﻠﺪ ﻋﻠﻰ داﺋﺮة ﻧﺼﻒ ﻗﻄﺮھﺎ‬ appliance adhesive. The skin must be
‫ ﺳﻢ( ﺣﻮل اﻟﻔﺘﺤﺔ واﺗﺮﻛﮭﺎ‬5) ‫ﺑﻮﺻﺔ‬ ‫ﯾﺤﺘﺎج اﻟﺠﻠﺪ إﻟﻰ اﻟﺤﻤﺎﯾﺔ ﻣﻦ اﻟﺘﺄﺛﯿﺮ اﻟﻤﻔﺮط‬
‫ ﯾﺠﺐ أن‬.‫ﻟﻺﻓﺮاز واﻟﻤﻮاد اﻟﻼﺻﻘﺔ ﻟﻠﺠﮭﺎز‬
‫ﯾﻜﻮن اﻟﺠﻠﺪ‬

Page 89
dry completely, which takes about 30 perfectly dry before the appliance is placed to get
seconds. good adherence and to prevent leaks.
.‫ ﺛﺎﻧﯿﺔ‬30 ‫ وﯾﺴﺘﻐﺮق ذﻟﻚ ﺣﻮاﻟﻲ‬، ‫ﯾﺠﻒ ﺗﻤﺎًﻣﺎ‬ ‫ﯾﺠﻒ ﺗﻤﺎًﻣﺎ ﻗﺒﻞ وﺿﻊ اﻟﺠﮭﺎز ﻟﻠﺤﺼﻮل ﻋﻠﻰ اﻟﺘﺼﺎق ﺟﯿﺪ‬
.‫وﻟﻤﻨﻊ اﻟﺘﺴﺮﺑﺎت‬

15. Lift the gauze squares for a moment and The appliance should fit snugly around the
measure the stoma opening, using the stoma, with only 1/8 inch of skin visible
measurement guide. Replace the around the opening. Afaceplate

gauze. Trace the same-size opening on the


back center of the appliance. Cut theopening
1/8 inch larger than the stoma size. opening that is too small can cause traumato the
stoma. If the opening is too large, exposed skin
‫ارﻓﻊ ﻣﺮﺑﻌﺎت اﻟﺸﺎش ﻟﻠﺤﻈﺔ وﻗﻢ ﺑﻘﯿﺎس ﻓﺘﺤﺔ اﻟﻔﻐﺮة‬
will be irritated by stool.
‫ ﺗﺘﺒﻊ اﻟﻔﺘﺤﺔ‬.‫ اﺳﺘﺒﺪل اﻟﺸﺎش‬.‫ﺑﺎﺳﺘﺨﺪام دﻟﯿﻞ اﻟﻘﯿﺎس‬
‫ ﺑﺤﯿﺚ ﻻ ﯾﻈﮭﺮ‬، ‫ﯾﺠﺐ أن ﯾﻜﻮن اﻟﺠﮭﺎز ﻣﺤﻜًﻤﺎ ﺣﻮل اﻟﻔﺘﺤﺔ‬
‫ذات اﻟﺤﺠﻢ ﻧﻔﺴﮫ ﻓﻲ ﻣﻨﺘﺼﻒ اﻟﺠﺰء اﻟﺨﻠﻔﻲ ﻣﻦ‬
.‫ ﺑﻮﺻﺔ ﻣﻦ اﻟﺠﻠﺪ ﺣﻮل اﻟﻔﺘﺤﺔ‬8/1 ‫ﺳﻮى‬
.‫ ﺑﻮﺻﺔ أﻛﺒﺮ ﻣﻦ ﺣﺠﻢ اﻟﻔﻐﺮة‬8/1 ‫ ﻗﻄﻊ ﻓﺘﺢ‬.‫اﻟﺠﮭﺎز‬

.‫اﻟﻔﺘﺤﺔ اﻟﺼﻐﯿﺮة ﺟﺪًا ﯾﻤﻜﻦ أن ﺗﺴﺒﺐ ﺻﺪﻣﺔ ﻓﻲ اﻟﻔﻐﺮة‬


‫ ﻓﺴﻮف ﯾﺘﮭﯿﺞ اﻟﺠﻠﺪ‬، ‫إذا ﻛﺎﻧﺖ اﻟﻔﺘﺤﺔ ﻛﺒﯿﺮة ﺟﺪًا‬
.‫اﻟﻤﻜﺸﻮف ﺑﺴﺒﺐ اﻟﺒﺮاز‬
16. Remove the backing from the appliance. The appliance is effective only if it is properly
Quickly remove the gauze squares and ease positioned and adhered securely.
the appliance over the stoma. ‫اﻟﺠﮭﺎز ﻓﻌﺎل ﻓﻘﻂ إذا ﺗﻢ وﺿﻌﮫ ﺑﺸﻜﻞ ﺻﺤﯿﺢ وﻟﺼﻘﮫ‬
Gently press onto the skin while smoothing .‫ﺑﺈﺣﻜﺎم‬
over the surface. Apply gentlepressure to
appliance for 5 minutes.
‫ ﻗﻢ ﺑﺈزاﻟﺔ ﻣﺮﺑﻌﺎت اﻟﺸﺎش‬.‫ﻗﻢ ﺑﺈزاﻟﺔ اﻟﻐﻄﺎء ﻣﻦ اﻟﺠﮭﺎز‬
.‫ﺑﺴﺮﻋﺔ وﺧﻔﻒ اﻟﺠﮭﺎز ﻓﻮق اﻟﻔﺘﺤﺔ‬
‫ ﺿﻊ‬.‫اﺿﻐﻂ ﺑﺮﻓﻖ ﻋﻠﻰ اﻟﺠﻠﺪ ﻣﻊ ﺗﻨﻌﯿﻢ اﻟﺴﻄﺢ‬
ً ‫ﺿﻐ‬
.‫ دﻗﺎﺋﻖ‬5 ‫ﻄﺎ ﻟﻄﯿﻔًﺎ ﻋﻠﻰ اﻟﺠﮭﺎز ﻟﻤﺪة‬

Page 90
17. Close bottom of appliance or pouch by A tightly sealed appliance will not leak and
folding the end upward and using the clamp cause embarrassment and discomfort for the
or clip that comes with the product, or secure patient.
Velcro closure. Ensurethe curve of the clamp ‫ﻟﻦ ﯾﺘﺴﺮب اﻟﺠﮭﺎز اﻟﻤﺤﻜﻢ اﻹﻏﻼق وﯾﺴﺒﺐ اﻹﺣﺮاج‬
follows the curve of the patient’s body. .‫وﻋﺪم اﻟﺮاﺣﺔ ﻟﻠﻤﺮﯾﺾ‬
‫أﻏﻠﻖ اﻟﺠﺰء اﻟﺴﻔﻠﻲ ﻣﻦ اﻟﺠﮭﺎز أو اﻟﺤﻘﯿﺒﺔ ﻋﻦ طﺮﯾﻖ‬
‫طﻲ اﻟﻨﮭﺎﯾﺔ ﻷﻋﻠﻰ واﺳﺘﺨﺪام اﻟﻤﺸﺒﻚ أو اﻟﻤﺸﺒﻚ اﻟﺬي‬
‫ ﺗﺄﻛﺪ ﻣﻦ‬.‫ أو إﻏﻼق اﻟﻔﯿﻠﻜﺮو ﺑﺈﺣﻜﺎم‬، ‫ﯾﺄﺗﻲ ﻣﻊ اﻟﻤﻨﺘﺞ‬
.‫أن ﻣﻨﺤﻨﻰ اﻟﻤﺸﺒﻚ ﯾﺘﺒﻊ ﻣﻨﺤﻨﻰ ﺟﺴﻢ اﻟﻤﺮﯾﺾ‬

18. Remove gloves. Assist the patient to a Provides warmth and promotes comfort and
comfortable position. Cover the patientwith safety.
bed linens. Place the bed in the lowest .‫ﯾﻮﻓﺮ اﻟﺪفء وﯾﻌﺰز اﻟﺮاﺣﺔ واﻷﻣﺎن‬
position.
.‫ ﺳﺎﻋﺪ اﻟﻤﺮﯾﺾ ﻓﻲ وﺿﻊ ﻣﺮﯾﺢ‬.‫اﻧﺰع اﻟﻘﻔﺎزات‬
‫ ﺿﻊ اﻟﺴﺮﯾﺮ‬.‫ﺗﻐﻄﯿﺔ اﻟﻤﺮﯾﺾ ﺑﺒﯿﺎﺿﺎت اﻟﺴﺮﯾﺮ‬
.‫ﻓﻲ أدﻧﻰ وﺿﻊ‬
19. P ut on clean gloves. R em ove or discard Gloves prevent contact with blood, body fluids,
equipment and assess patient’s responseto and microorganisms that contaminatethe used
procedure. equipment. The patient’s response may indicate
‫ ﻗﻢ ﺑﺈزاﻟﺔ أو اﻟﺘﺨﻠﺺ ﻣﻦ‬.‫ارﺗِﺪ ﻗﻔﺎزات ﻧﻈﯿﻔﺔ‬ acceptance of the ostomy as well as the need for
.‫اﻟﻤﻌﺪات وﺗﻘﯿﯿﻢ اﺳﺘﺠﺎﺑﺔ اﻟﻤﺮﯾﺾ ﻟﻺﺟﺮاء‬ health teaching.
‫ﺗﻤﻨﻊ اﻟﻘﻔﺎزات ﻣﻼﻣﺴﺔ اﻟﺪم وﺳﻮاﺋﻞ اﻟﺠﺴﻢ واﻟﻜﺎﺋﻨﺎت‬
‫ ﻗﺪ ﺗﺸﯿﺮ‬.‫اﻟﺤﯿﺔ اﻟﺪﻗﯿﻘﺔ اﻟﺘﻲ ﺗﻠﻮث اﻟﻤﻌﺪات اﻟﻤﺴﺘﺨﺪﻣﺔ‬
‫اﺳﺘﺠﺎﺑﺔ اﻟﻤﺮﯾﺾ إﻟﻰ ﻗﺒﻮل اﻟﻔﻐﺮ وﻛﺬﻟﻚ اﻟﺤﺎﺟﺔ إﻟﻰ‬
.‫اﻟﺘﺪرﯾﺲ اﻟﺼﺤﻲ‬
20. Remove gloves and additional PPE, if Removing PPE properly reduces the risk for
used. Perform hand hygiene. infection transmission and contamination ofother
، ‫ﻗﻢ ﺑﺈزاﻟﺔ اﻟﻘﻔﺎزات وﻣﻌﺪات اﻟﻮﻗﺎﯾﺔ اﻟﺸﺨﺼﯿﺔ اﻹﺿﺎﻓﯿﺔ‬ items. Hand hygiene prevents the spread of
.‫ ﻗﻢ ﺑﻨﻈﺎﻓﺔ اﻟﯿﺪﯾﻦ‬.‫إذا ﺗﻢ اﺳﺘﺨﺪاﻣﮭﺎ‬ microorganisms.
‫ﺗﻘﻠﻞ إزاﻟﺔ ﻣﻌﺪات اﻟﻮﻗﺎﯾﺔ اﻟﺸﺨﺼﯿﺔ ﺑﺸﻜﻞ ﺻﺤﯿﺢ ﻣﻦ‬
‫ ﺗﻤﻨﻊ‬.‫ﺧﻄﺮ اﻧﺘﻘﺎل اﻟﻌﺪوى وﺗﻠﻮث اﻟﻌﻨﺎﺻﺮ اﻷﺧﺮى‬
.‫ﻧﻈﺎﻓﺔ اﻟﯿﺪﯾﻦ اﻧﺘﺸﺎر اﻟﻜﺎﺋﻨﺎت اﻟﺪﻗﯿﻘﺔ‬
21. Document: To ensures continuity of care.
- Appearance of stoma, condition of .‫ﻟﻀﻤﺎن اﺳﺘﻤﺮارﯾﺔ اﻟﺮﻋﺎﯾﺔ‬
peristomal skin
:‫وﺛﯿﻘﺔ‬
‫ ﺣﺎﻟﺔ اﻟﺠﻠﺪ اﻟﺘﻤﮭﯿﺪي‬، ‫ ظﮭﻮر اﻟﺜﻐﺮة‬-