PRODUCT CATALOGUE
We are
SENSITIVE to Fire!
We serve with our wide product range in electric and
diesel-driven fire pumps.
With its expertise in fire systems, Duyar pompa manufactures fire pumps and pumping systems that work
reliably when required, comply with the NFPA 20 ve EN 12845 standards. The manufactured fire fighting
sets are used in;
.
Building Technologies
.
Industrial Facilities
.
Power Plants
.
Fuel and Gas Industries.
Low Installation
and Operation
Costs
Our leading-edge technology, highly efficient pumps
ensure;
.
Less power consumption .
.
Smaller equipment options .
.
Smaller cabinets.
3
Areas of Use
Building Technologies
Industrial Facilities
Power Plants
Fuel and Gas Industry
4
NFPA
National Fire Protection Association (NFPA) was established by a group of
insurers in the USA in 1896 to minimize the effects of fire and other risks. NFPA
20 is the most wide-spread and detailed resource used worldwide in fire-fighting
systems that defines the requirements regarding the installation of the fire
pumps which are used in fire protection. NFPA 20 covers the selection,
installation, acceptance test, and operation of fire pumps.
Material Properties
.
Casing : GG25 (Gray Cast Iron) cabinets.
.
Impeller : CuSn10 (Bronze) – AISI 304 .
In the nominal flow rate, the rate of flow in the
.
Shaft : AISI 316 - AISI 420 suction line is less than 3 m/s'.
.
Shaft Bushing : AISI 316 - AISI 304 In NFPA 20, suction line diameters of fire pumps
.
Sealing : Should be supplied together are specified according to the maximum speed
with the soft packing ring with under 150% of the nominal flow rate. (4,6 m/sec).
a minimum of five (5) windings. The service factor of electric motors (overload
.
Bearing : Bearings should have a minimum factor) should not exceed 1.15.
of 5000 hours lifetime in maximum .
There should be a OS & Y Gate Valve in between
load condition. the suction line and suction collector of fire
pumps.
What Are the Characteristics of a Pump System .
Strainers should never be placed on the suction
That Complies with NFPA 20? line.
.
Standard pump types are specified as Horizontal .
On the discharge line of fire pumps, there should
Split Case Pump, Horizontal End-Suction Pump, a check valve and butterfly valve, respectively.
Horizontal Multi-Stage End-Suction Pump, .
If the electric fire pumps with backup power
Inline Pump, and Vertical Turbine Pump. are selected, there should be a prime power
.
Among the fire pumps, NFPA 20 allows source that will continue to supply the pumps
negative suction only for “Vertical Turbine and cabinets. If there is no backup power source,
Pumps;” end-suction and split case pumps at least one of the pumps should have a diesel
should never be operated under negative engine.
suction. .
A Jockey pump is used to eliminate the minor
.
The fire pump curve should ensure the 150% pressure drops in the fire line without the need
capacity of the nominal flow rate, and the value for activating the main fire pumps; its flow rate
of pressure at %150 flow rate capacity cannot be should be minimum 1/100 of the flow rate of main
less than 65% of nominal pressure. fire pump, and its pressure should be at least 1
.
The closed valve pressure value of fire pump bar more than that of the main fire pump.
(the maximum pressure that the pump can
provide under zero flow rate) should not exceed
140% of the nominal value.
.
Each pump should have independent control
Performance Curves
Pump Characteristic Curve According to NFPA
140
122
Operating Point
120
100
100
Pump Head (%)
80
Minimum allowed pressure 82
65
60
40
0
0 50 100 150
Nominal Flow Rate (%)
5
TS EN 12845 + A1
This European Standard had been prepared by technical committee
of Fixed Firefighting Systems and approved by CEN on 12 December.
CEN members are the national standards bodies of Austria, Belgium,
Bulgaria, Croatia, Cyprus, Czech Republic, Denmark, Estonia, Finland,
France, Germany, Greece, Hungary, Iceland, Ireland, Italy, Latzia,
.
Pumps shall have stable H (Q) performance switch. Two pressure switches shall be
curve. provided to start each pumpset.
.
The pump shall be capable of supplying .
Where two pumps are installed, each one
140% of this flow at a pressure of no less shall be capable independently of providing
than 70% of the pressure at the design pump the specified flows and pressures. Where
flow. three pumps are installed, each pump shall
.
The pumps shall be start by pressure drop be capable of providing at least 50 % of the
in the system that is taken from pressure specified flow at the specified pressure.
Performance Curves
y
Pressure
100%
1x
70%
100% 140% x
Flow
6
DSP
Horizontal Split Case Pump
Material Properties
Pump Casing GG25 (Cast Iron) - GGG40 (Sferoo)
Technical Properties
Fluid Temperature -20 / +80 °C
System Equipment
Air Discharge Valve Check Valve Jockey Pump Pressure Switch
Product Specifications
.
Pumps have double-suction, horizontal split case, and their suction-discharge flanges are aligned
in the lower casing.
.
Thanks to the optimized efficiency, provides low operating cost.
.
Thanks to the low NPSH values, it allows cavitation-free operation.
.
Impellers are balanced in accordance with ISO 1940 class 6.3.
.
Has grease bearing and soft packing.
.
The pump rotates clockwise according to the motor side.
.
The equipment used in the suction and discharge lines is of ‘Duyar Valve' brand.
.
Suction and discharge flanges comply with the ISO 7005-2/PN16 standard.
.
Flanges can be optionally produced in ANSI norms.
7
Performance Curves
180
160
140
10
0/
80/315 31
5
120
Pump Head (mSS)
100 125/315
60/250
200/500
80
15
0/3
250
15
0
25
80/
0/
10
60
40
20
0
0 200 400 600 800 1000 1200 1400
8
Horizontal Split Case Pump
“Split case”
construction
“Efficient”
impellor design
“Corrosion
resistant”
stainless cover
Ease of
“Maintenance/
Mounting/
Dismantling”
“Ergonomic”
design
“High casting”
quality
9
DNP
Horizontal End-Suction Pump
Material Properties
Pump Casing GG25 (Cast Iron)
Technical Properties
Fluid Temperature -20 / +80 °C
System Equipments
Relief Valve Manometer Expansion Tank Pressure Switch
Ürün Özellikleri
.
These are single-stage, end-suction, closed-impeller, axial pumps.
.
Pump and motor connections are made on the common chassis using a flexible coupling.
.
Equipped with grease bearings that have a long life.
.
Soft packings are used for sealing.
.
The pump rotates clockwise with reference to the motor side.
.
The equipment used in the suction and discharge lines is of ‘Duyar Valve' brand.
.
Suction and discharge flanges comply with the ISO 7005-2/PN16 standard.
10
Performance Curves
200
180
160 50
-3
140 15
80
120 40 65 -3 15
-3 -3 15 10 0-
15 15 0- 31
Pump Head (mSS)
100 31 5
5
90 80
32 40 65 -2
80 -2 -2 -2 50 10
50 50 50 50 0-
25
70 -25 0
0 12
5-
60 25
0
50 80
40 -2 -2
50 -2 00 00
00 65
-2
00 10
40 0- 12
20 5-
0 20
0
30
6
6 7 8 9 10 15 20 30 40 50 100 150 200 300 400 500 600 750 900 1050
11
DMP
Horizontal Multi-Stage Pump
Material Properties
Pump Casing GG25 (Cast Iron) - GGG40 (Sfero)
Technical Properties
Fluid Temperature -20 / +80 °C
System Equipments
Casing Relief Valve Manometer Expansion Tank Pressure Switch
Product Specifications
.
Used in the projects where high pressure is required.
.
Soft packing is used as a sealing element.
.
Impellors are produced with balance holes to compensate the axial loads.
.
Cylindrical roller bearings that have a long life and withstand heavy conditions are used in the pumps.
.
The pump rotates clockwise with reference to the motor side.
.
Suction and pressure flanges can be PN16, PN25, or PN40 if required.
.
Case castings can be GG25 (CAST IRON) or GG40 (SFERO) according to the desired pressure.
12
Performance Curves
2.900 d/d
450
400
350
300
DM
DM P5
250 P4 0
0 DM
200 P6
DM 5
P3
2
150 DM
P8
100 0
50
Pump Head (mSS)
0
6 60 600
1.450 d/d
300
250
200 DM DM
P1 DM
25 P1 P2
50 00
150
100
50
0
130 1300
13
CONTROL PANELS
Whether it is electric or diesel-driven, each pump is provided with manual or automatic controls
separately and independently through the electric and/or diesel control panel. Our panels are
produced according to the NFPA 20 standards. They are compact fire-fighting equipment suitable
for automation, easy to use, and maintain with the alarm and control features.
14
DIESEL-DRIVEN CONTROL PANEL
.
Double-battery system
.
Current-voltage monitoring through the display
.
Monitoring the temperature value via the temperature
switch
.
Monitoring the oil pressure with the oil pressure switch
.
Monitoring the fuel status on display.
.
Ability to limit the number of starts
.
Ability to adjust the starting time
.
Manual start/stop feature
.
Diesel operation period monitoring through the display
.
Ability to adjust the diesel stop delay (1-240 minutes)
.
Low battery voltage notification
.
Monitoring the diesel rotation (RPM) on display
.
Ability to test twice a week
.
Ability to use a pressure transmitter
.
With BMS feature, notification of all fault/operation
conditions via relay contact
.
Turkish/English menu
.
Displaying date and time
.
4x20 LCD display
.
Automatic - Manual operation switch
.
Vertical Multi-Stage pump (with chassis)
.
Electric motor
.
Control panel
.
100 lt expansion tank
.
Ball valve
.
Check valve
.
Pressure Switch
.
Level Floater
15
Quality , Reliable , Innovative
2020.2.2