You are on page 1of 1

CORBELS MCB2

CORBELS MCB2
With welds
This detail is suitable when using 20mm bar size or smaller for the main tensile reinforcement
Nominal cover specified by designer

Two column links should be


placed close to corbel top

Distance between edge of bearing


and outside of plate or bar should
not be less than the vertical
cover to the plate or bar

Large radius of
bend required
A A

Main tensile bars


welded to a cross
bar, or plate,
and to the vertical
compression bars

Horizontal links. Total


Tension lap area should not be less
than 0.50 of area of
the main tensile
reinforcement

Compression bars. Total area of


which should not be less than
1000mm2/metre width of corbel

Compression anchorage

A-A

132 Chapter six IStructE/Concrete Society Standard Method of Detailing Structural Concrete