You are on page 1of 11

Installation of additional

stiffener angle inside of tank

PT is required
1. Sketch drawing

Wh
tbr
L
A1
Wc : Max. width of participate shell
θ 375.46 mm
α 54 mm
Wh : Max. width of participate roof
tbS 432.00 mm

Wc L : Projection length 75 mm
A2 A4
Rc
R2 : Normal radius to roof 29,000 mm
96 mm
Rc : Inside radius of tank shell 14,503 mm
A3 (in corr. Allow)
alpa = phi/2 - θ 1.1345
6 mm
θ = 0.4363 rad
25 Deg

Compression ring thickness(Roof). Excl. corr. (tbr) 27.0 mm


Compression ring thickness(Shell). Excl. corr. (tbs) 27.0 mm
Top Shell plate thickness excluding corossion(ts) 3.0 mm
Roof plate thickness excluding corossion(tr) 5.0 mm
Corrosion allowance(CA) 3.0 mm

2.Attached angle area

a=175 mm
t=12 mm a= 175.0 mm
b= 175.0 mm
b=175 mm t= 12.0 mm
Angle area A4 3042.0 mm2

3. Actual area

Aac = Compression ring region area in corroded 25716.4 mm^2


= A1+A2+A3+A4

4. Required Compression ring area


(According to API 650, APPENDIX 'F', F.5)

200 × D 2 × ( P − 0.08 × tr )
ARe q = 25398.4 mm^2
Fy × tan θ

Where,
D= Tank diameter less corrosion 29.006 m
P= Design pressure 17.9960 kPa
Fy= Yield stress of roof plate 250.0 MPa

Result

Areq = 25398.5 mm2 < Aac= 25716.4 mm2 ---------------> SATISFIED

You might also like