You are on page 1of 15

First login

March 2016
Version 6

Agenda

• CLI and Web login


• General commands
• Get IP address
• Set IP address
• Set to default

2 Proprietary and Confidential


Connecting to the Unit
CLI

Baud rate = 115200


Web/Telnet
Data bits: 8
Parity: None
Stop bits: 1
Flow Control: None

IP address = 192.168.1.1

Default Username/password is admin/admin


3 Proprietary and Confidential

General commands

Press twice the TAB key for optional commands in actual directory
Use the TAB key to auto-complete a syntax

Use the arrow keys to navigate through recent commands

Question mark to list helpful commands

Q key to jump out from menu

4 Proprietary and Confidential


Get IP address

CLI Command:

“platform management ip show ip-address”

5 Proprietary and Confidential

Changing Management IP Address


• CLI Command:

“platform management ip set ipv4-address <IP Address> subnet <Mask>


gateway <default gateway>”

• Example

• Web
expand Platform branch, then Management branch and click on IP, set
accordingly and click Apply button

6 Proprietary and Confidential


Set to default
• CLI Command:
“platform management set-to-default”

Please note that IP address after Set to


Factory Default will be not changed!!!

7 Proprietary and Confidential

Ethernet Management Interface IP-20G


• FibeAir IP-20G contains two FE management interfaces, which connect to a single RJ-45 physical
connector on the front panel (MGMT).

• If the user only needs to use a single management interface, a standard Cat5 RJ-45 cable (straight or
cross) can be connected to the MGMT interface.
• To access both management interfaces, a special 2 x FE splitter cable can be ordered from Ceragon.

• Port Status LED – The LED for management interface 1 is located on the upper left of the MGMT
interface. The LED for management interface 2 is located on the upper right of the MGMT interface.

8 Proprietary and Confidential


Enable Second MNG port via Splitter

CH1

CH2

• CH2 used for the same MNG IP address

9 Proprietary and Confidential

Enable Second MNG port via Splitter

10 Proprietary and Confidential


Web Management

11

First Web login

Default IP address is 192.168.1.1 / 255.255.255.0 (24)


Default Username/password is admin/admin

12 Proprietary and Confidential


Platform / Management / Unit Parameters

13 Proprietary and Confidential

Platform / Management / NTP Configuration

14 Proprietary and Confidential


Platform / Management / Time Services

15 Proprietary and Confidential

Platform / Management / Interface Manager

Default status is
! DOWN ! Managing of all ports

16 Proprietary and Confidential


Platform / Management / Inventory

Serial Number
important for
activation key
generating

17 Proprietary and Confidential

Platform / Management / Unit Info

Create Unit Information file, see


configuration in Backup chapter

18 Proprietary and Confidential


Platform / Management / Reset

Provide software reboot

19 Proprietary and Confidential

Platform / Management / Set to Factory Default

Clear configuration database

20 Proprietary and Confidential


IP address settings

21 Proprietary and Confidential

SNMP Parameters

Setting for NMS system

22 Proprietary and Confidential


Trap Managers

Up to 4 Trap Managers

23 Proprietary and Confidential

V3 User

Setting for SNMP v3

24 Proprietary and Confidential


CLI Exercise

25

Exercise
• CLI or Telnet (hyper-terminal, telnet, putty, ZOC etc. for connection to
your element)

PREPARATION BEFORE START:

• Open latest "User Guide" for IP-20 with CLI commands


• Recommendation is to use two PCs:

PC #1 use for management of your NE


PC #2 use for seeking of commands in User Guide (in your PC)

26 Proprietary and Confidential


CLI Exercise
1. Connect to your Element via CLI or Telnet
2. Set system to default settings - Factory reset (system will restart automatically)
a) use keyboard "Q" to jump back to root menu
b) for execution of command you have to type whole command "yes"
c) What IP address are you going to use for connection after restart?
c) How much does it take to restart unit? (use ping command ping 192.168.1.x -t)
3. Show IP address of your element
a) What is the IP address? mask? gateway after Factory reset?
4. Change IP address of your element to: 192.168.1. actual IP address +10 (10 to 20 etc.)
5. Check IP address back + mask + gateway
6. Reconnect to original IP address via Telnet (or CLI)
7. Set "Unit Info" - Set in Unit Parameters - "System name" of your group (Group 1 for an example)
a) Unit info is menu where you can place address of side, GPS coordinates, contact person, phone numbers etc.
b) Are you able to check Unit info via CLI? (try login via web and check correct settings via web GUI)
c) check Unit Info - platform management unit-status
8. Check IF - Manager for actual ports configuration - Show all Interface
a) how many ports are by default enabled for management?
9. Enable second port for management
a)check IF - MANAGER if second port is up
10. Set correct date and time for your system
a)Setup exactly the same time as in your PC
b) correct time settings was very important for old software versions upgrade (7.0)
11. Show all interfaces status (if-manager)
a) this command will help you to see status of all interfaces and ports in system
12. Show all slots status in "shelf-manager"

27 Proprietary and Confidential

Agenda

 CLI and Web login


 General commands
 Get IP address
 Set IP address
 Set to default

28 Proprietary and Confidential


Thank You