Professional Documents
Culture Documents
The LP-4000™ series Data Acquisition and Control instrument employs our proprietary LaserViewer™ data acquisition
and reporting software, a commercially produced, standard product employing a Windows™-based platform.
LaserViewer™ is designed for use on the LP-4000™ series DAC instrument to acquire multi-channel laser profilometry,
LaserVideo™ imaging (LVI), laser-scanned FPI and straightness data in the laboratory, shop or field.
LP-4000™ Data Acquisition and Control Instrument LP-4210F™ Field Grade DAC Instrument
LaserViewer™ is an operator-configurable laser sensor and motion control software interface. It allows the operator to
create and run complex scan routines. Laser control can be modified through the software to adapt to different surfaces
and reflectivity to optimize inspection data through gain control, power level and intensity.
Data Acquisition
LaserViewer™ displays calibrated data in real-time during the inspection scanning process. Data acquisition routines
are operator operator-configurable and can be saved as unique Workspaces. Performance calculations display the
estimated scan duration, completion time and data rate
LaserViewer™ displays a color plot image of calibrated profile and LaserVideo™ information with cross-sectional and
axial display of surface profile data. Analysis modules for post processing of data including but not limited to calculating:
area, ovality, max fs diameter, minimum diameter, horizontal reference subtraction, vertical reference subtraction,
remove centering offset, remove DC offset, remove undefined data, remove bad data, variable median filter, averaging
filter, and invert data
LaserViewer™ can be configured for customer-specific applications. In this manner, only functions and views specifically
required for a given task are displayed to the operator. The graphic user interface can be configured for simplicity of
operation and application-specific functionality. In addition, a variety of custom data analysis modules are available.
11431 Willows Road NE · Suite 100 · Redmond, WA 98052 · Phone (425) 885-0607 · Fax (425) 885-0802 · www.laser-ndt.com
LaserViewer™ Advanced Analysis Software
Diameter (in.)
SCAN DATA AXIAL RESOLUTION: 0.02 in
REPORT AXIAL RESOLUTION: 0.5 in Average Lands
0.5050
NUMBER OF LAND SAMPLES PERCALCULATION: 15 Average Grooves
NUMBER OF GROOVE SAMPLESPER CALCULATION: 31
REPORT GENERATED ON: 1/30/2004
0.5000
NOTE: Land 1 is the first land above 0 degrees at the muzzle end.
COMMENTS:
0.4950
Diameter calculations
Dist. from Scan Lands Grooves Lands Grooves Lands Grooves Lands Grooves Average Average 0.4900
muzzle pos. 1&5 1&5 2&6 2&6 3&7 3&7 4&8 4&8 Lands Grooves
0.5 -39.22 0.4950 0.5080 0.4965 0.5090 0.4955 0.5090 0.4950 0.5085 0.4955 0.5086
1 -38.72 0.4950 0.5080 0.4955 0.5085 0.4955 0.5090 0.4945 0.5080 0.4952 0.5084 0.4850
1.5 -38.22 0.4955 0.5085 0.4960 0.5090 0.4950 0.5090 0.4950 0.5080 0.4954 0.5086 0 5 10 15 20 25 30 35 40 45
2 -37.72 0.4955 0.5090 0.4955 0.5090 0.4950 0.5085 0.4955 0.5080 0.4954 0.5086 Distance from muzzle (in.)
2.5 -37.22 0.4960 0.5085 0.4955 0.5085 0.4950 0.5080 0.4955 0.5080 0.4956 0.5083
3 -36.72 0.4965 0.5090 0.4960 0.5085 0.4955 0.5080 0.4955 0.5075 0.4958 0.5083 Figure 17. Plot of average diameters for lands and grooves.
3.5 -36.22 0.4965 0.5090 0.4960 0.5085 0.4955 0.5080 0.4965 0.5080 0.4962 0.5084
4 -35.72 0.4965 0.5090 0.4960 0.5085 0.4960 0.5080 0.4970 0.5080 0.4964 0.5083
4.5 -35.22 0.4965 0.5085 0.4960 0.5085 0.4965 0.5080 0.4965 0.5085 0.4963 0.5083
5 -34.72 0.4965 0.5085 0.4960 0.5080 0.4965 0.5080 0.4970 0.5085 0.4964 0.5084
5.5 -34.22 0.4965 0.5090 0.4960 0.5080 0.4970 0.5080 0.4970 0.5085 0.4966 0.5084
6 -33.72 0.4965 0.5085 0.4965 0.5080 0.4970 0.5080 0.4965 0.5090 0.4965 0.5085
6.5 -33.22 0.4965 0.5085 0.4965 0.5080 0.4970 0.5090 0.4965 0.5090 0.4967 0.5086
7 -32.72 0.4965 0.5080 0.4970 0.5085 0.4970 0.5090 0.4965 0.5090 0.4968 0.5087
7.5 -32.22 0.4965 0.5090 0.4975 0.5085 0.4970 0.5095 0.4965 0.5090 0.4968 0.5090
8 -31.72 0.4970 0.5085 0.4975 0.5095 0.4970 0.5095 0.4965 0.5090 0.4970 0.5092
8.5 -31.22 0.4970 0.5090 0.4980 0.5095 0.4965 0.5095 0.4965 0.5090 0.4970 0.5093
9 -30.72 0.4975 0.5095 0.4980 0.5100 0.4970 0.5095 0.4965 0.5090 0.4973 0.5095
LaserViewer™ Advanced Analysis is an add-on software package designed for in-depth analysis and reporting of
complex laser profile data sets. This software module is intended for use "off-site" to provide enhanced capabilities with
the freedom and portability to conduct remote data analysis and collaboration. Separate from the Data Acquisition and
Control instrument, LaserViewer™ Advanced Analysis is ideal for presentations and remote-located decision-makers,
allowing the LP-4000™ series DAC instrument to continue collecting data.
· Reference subtraction
11431 Willows Road NE · Suite 100 · Redmond, WA 98052 · Phone (425) 885-0607 · Fax (425) 885-0802 · www.laser-ndt.com