PROJECT :

FILE PATH: 'file:///conversion/tmp/activity_task_scratch/588873111.xls'#$5-Pile

Design for 5-Pile Group (Square group)

Concrete Fck,Steel Fy 30 500 N/mm2


Pile Dia (hp) 600 mm
Column Dim (a,b) 600 600 mm
Spacing factor of piles (α) 2.75
Spacing between centers of piles (l) 2333 mm
Thickness of pile cap (h) 1350 mm
Width of pile cap 3233 mm
Length of Pile Cap 3233 mm

Tensile forces to be resisted by reinforcement


Load on column (N) 360 Ton
Effective depth of pile cap (d) 1275 mm

Neglecting Column Size (Nl/10d)


Tensile for to be resisted by reinforcement 65.89

Taking size of column into consideration


Parallel to X-X 64.43
Parallel to Y-Y 64.43

Tensile steel required (Sq. In) 5.47


Tensile steel required (Sq.cm) 5.47
Reinforcement @ 0.15% of Pile cap area X-X plane 6183.98 mm2
Reinforcement @ 0.15% of Pile cap area Y-Y plane 6183.98 mm2

Provide reinforcement in X-Direction


Bar Dia 20 mm
Number Of Bars Required 19.7
Number Of Bars Provided 20
Ast Provided 6280
SAFE

Provide reinforcement in Y-Direction


Bar Dia 25 mm
Number Of Bars Required 20.0
Number Of Bars Provided 25
SAFE

Oneway Shear
Diagonal tension @ 0.5d distance from face of
pedestal 637.5 mm
Shear Force,VU 1800 kN
Percentage of Steel,Pt 0.00 %
Shear strenth of concrete,Tc 0.21 N/mm2
Shear stress,Tv 0.44 N/mm2
DESIGN FOR SHEAR

Design Shear,Vus 934243.1 N


Bar dia 10 78.5
Spacing of Stirrups,Sv 279.615 mm
say provide stirrups 6lgd-10Ø @ 200 mm c/c
DEALT :
DATE :

2333

3233

3233
PLAN

1350

#20-20 dia
B/W
DEPTH
PILE

600 Ø 600 Ø 600 Ø

SECTION

You might also like