You are on page 1of 14

TAMEER CONSULTING ASSOCIATES

PROJECT : RAJKUMAR, HYDERABAD.


FILE PATH: 'file:///conversion/tmp/activity_task_scratch/730733216.xls'#$2-Pile

Concrete,Steel 20 500 N/mm2


Pile Dia (hp) 300 mm
Pedestal Dim (a,b) 230 380 mm
Spacing factor of piles (α)
Spacing between centers of piles (l) 1140 mm
Thickness of pile cap (h) 380 mm
Width of pile cap 900 mm 900
Length of pile cap 1750 mm
Tensile forces to be resisted by reinforcement
Load on column (N) 67 ton
Effective depth of pile cap (d) 305 mm

Neglecting Column Size 63 ton

Taking size of column into consideration 4 ton


380
Tensile steel required (Sq. In) 4.25
Tensile steel required (Sq.cm) 2.20
Reinforcement @ 0.15% of Pile cap area 513.00 380

Bar Dia 12
Number Of Bars Required 4.5
Number Of Bars Provided 5
Ast Provided 565.506
SAFE
DESIGN FOR SHEAR
Oneway Shear
One-Way shear @ 0.5d distance from face of H
pedestal 152.5 mm DEPT
Shear Force 502.5 kN
PILE

Percentage of Steel,Pt 0.21 %


Shear strenth of concrete,Tc 0.30 N/mm2
Shear stress,Tv 0.94 N/mm2
Vus 420150 N
Consider 6-legged bars of dia 10 mm 75.25
Shear spacing,Sv 142.5747 mm
Spacing Provided 125 mm
Provide 10 mm dia bars at a spacing of 125 mm c/c
Two-Way Shear
punching shear @d/2 dist around the
pedestal face
Shear force 502.5 kN
Punching shear section bo 840 mm
shear stress Tv 1.96 N/mm2
Allowable shear stress,Tc 1.12 N/mm2
Design for Shear
TES
DEALT : XXXXXXX
DATE : 13-Sep-18

1140

1750
PLAN
b
0.5d

#5-12 dia
B/W

H b
DEPT
PILE

300 Ø 300 Ø
SECTION
TAMEER CONSULTING ASSOCIATES
PROJECT : RAJKUMAR, HYDERABAD.
FILE PATH: 'file:///conversion/tmp/activity_task_scratch/730733216.xls'#$3-Pile

Design for 3-Pile Group

Concrete Fck,Steel Fy 20 500 N/mm2


Pile Dia (hp) 300 mm
Column Dim (a,b) 230 450 mm
Spacing factor of piles (α) 2.75
Spacing between centers of piles (l) 1140 mm
Thickness of pile cap (h) 530 mm 1600
Width of pile cap 1750 mm
Length of Pile Cap 1600 mm

Tensile forces to be resisted by reinforcement


Load on column (N) 76 Ton
Effective depth of pile cap (d) 455 mm

Neglecting Column Size (Nl/9d) 21.16


Taking size of column into consideration
Parallel to X-X 20.73
Parallel to Y-Y 19.51

Tensile steel required (Sq. In) 1.76


Tensile steel required (Sq.cm) 10.58
Reinforcement @ 0.15% of Pile cap area X-X plan 1194.38 mm2
Reinforcement @ 0.15% of Pile cap area Y-Y plan 1092.00 mm2 530

Provide reinforcement in X-Direction


Bar Dia 12 mm
Number Of Bars Required 6.0
Number Of Bars Provided 7
Ast Provided 791.7084
SAFE

Provide reinforcement in Y-Direction


Bar Dia 12 mm
Number Of Bars Required 6.0
Number Of Bars Provided 7
Depth
Pile
SAFE

Oneway Shear
Diagonal tension @ 0.5d distance from face of
pedestal 227.5 mm
Shear Force,VU 380 kN
Percentage of Steel,Pt 0.10 %
Shear strenth of concrete,Tc 0.21 N/mm2
Shear stress,Tv 0.48 N/mm2
DESIGN FOR SHEAR

Two-Way Shear
Design Shear,Vus 212787.5 N pedestal face
Bar dia 8 50.24 Shear force
Spacing of Stirrups,Sv 280.3854 mm Punching shear section bo
say provide stirrups 6lgd-8Ø @ 200 mm c/c Nominal shear stress Tv
Allowable shear stress,Tc
Safe, provide nominal sh
S
DEALT : XXXXXXX
DATE : 13-Sep-18

1140

X X
b
b

Y
1750y
725 PLAN b
c
c
o

=CONCATENATE("#",C33,"-",C37," dia")
B/W

b
c
c
Depth o
Pile

300 Ø 300 Ø
SECTION
Two-Way Shear
pedestal face
Shear force 380 kN
Punching shear section bo 1360 mm
Nominal shear stress Tv 0.61 N/mm2
Allowable shear stress,Tc 1.12 N/mm2
Safe, provide nominal shear rein
TAMEER CONSULTING ASSOCIATES
PROJECT : RAJKUMAR, HYDERABAD.
FILE PATH: 'file:///conversion/tmp/activity_task_scratch/730733216.xls'#$4-Pile

Design for 4-Pile Group (Square group)

Concrete Fck,Steel Fy 20 500 N/mm2


Pile Dia (hp) 300 mm
Column Dim (a,b) 230 450 mm
Spacing factor of piles (α) 2.75
Spacing between centers of piles (l) 1140 mm
Thickness of pile cap (h) 530 mm
Width of pile cap 1750 mm
Length of Pile Cap 1750 mm

Tensile forces to be resisted by reinforcement


Load on column (N) 92 Ton
Effective depth of pile cap (d) 455 mm

Neglecting Column Size (Nl/8d)


Tensile for to be resisted by reinforcement 28.81

Taking size of column into consideration


Parallel to X-X 28.42
Parallel to Y-Y 27.32

Tensile steel required (Sq. In) 2.39


Tensile steel required (Sq.In) 2.39
Reinforcement @ 0.15% of Pile cap area X-X plane 1194.38 mm2
Reinforcement @ 0.15% of Pile cap area Y-Y plane 1194.38 mm2

Provide reinforcement in X-Direction


Bar Dia 12 mm
Number Of Bars Required 13.6
Number Of Bars Provided 14
Ast Provided 1582.56
SAFE

Provide reinforcement in Y-Direction


Bar Dia 12 mm
Number Of Bars Required 13.6
Number Of Bars Provided 14
SAFE

Two way Shear


Diagonal tension @ 0.5d distance from face of pedestal 227.5 mm
Shear Force,VU 138 kN
Percentage of Steel,Pt 0.3 %
Shear strenth of concrete,Tc 0.33 N/mm2
Shear stress,Tv 0.22 N/mm2
Safe, provide nominal shear reinf
Design Shear,Vus -66204 N
Bar dia 10 78.5
Spacing of Stirrups,Sv -1408.112 mm
say provide stirrups 6lgd-10Ø @ 200 mm c/c
ATES
DEALT : XXXXXXX
DATE : 13-Sep-18

1140

340

1750

1750
PLAN

530

#14-12 dia
TH B/W
DEP
PILE

300 Ø 300 Ø
SECTION
TAMEER CONSULTING ASSOCIATES
PROJECT : RAJKUMAR, HYDERABAD.
FILE PATH: 'file:///conversion/tmp/activity_task_scratch/730733216.xls'#$5-Pile

Design for 5-Pile Group (Square group)

Concrete Fck,Steel Fy 20 500 N/mm2


Pile Dia (hp) 300 mm
Column Dim (a,b) 230 600 mm
Spacing factor of piles (α) 2.75
Spacing between centers of piles (l) 1140 mm
Thickness of pile cap (h) 610 mm
Width of pile cap 1750 mm
Length of Pile Cap 1750 mm

Tensile forces to be resisted by reinforcement


Load on column (N) 150 Ton
Effective depth of pile cap (d) 535 mm

Neglecting Column Size (Nl/10d)


Tensile for to be resisted by reinforcement 31.96

Taking size of column into consideration


Parallel to X-X 31.53
Parallel to Y-Y 29.01

Tensile steel required (Sq. In) 2.65


Tensile steel required (Sq.cm) 2.65
Reinforcement @ 0.15% of Pile cap area X-X plane 1404.38 mm2
Reinforcement @ 0.15% of Pile cap area Y-Y plane 1404.38 mm2

Provide reinforcement in X-Direction


Bar Dia 16 mm
Number Of Bars Required 8.5
Number Of Bars Provided 9
Ast Provided 1808.64
SAFE

Provide reinforcement in Y-Direction


Bar Dia 16 mm
Number Of Bars Required 9.0
Number Of Bars Provided 10
SAFE

Oneway Shear
Diagonal tension @ 0.5d distance from face of
pedestal 267.5 mm
Shear Force,VU 750 kN
Percentage of Steel,Pt 0.00 %
Shear strenth of concrete,Tc 0.21 N/mm2
Shear stress,Tv 0.80 N/mm2
DESIGN FOR SHEAR

Design Shear,Vus 553387.5 N


Bar dia 10 78.5
Spacing of Stirrups,Sv 198.0773 mm
say provide stirrups 6lgd-10Ø @ 200 mm c/c
CIATES
DEALT : XXXXXXX
DATE : 13-Sep-18

1140

1750

1750
PLAN

610

#9-16 dia
B/W
DEPTH
PILE

300 Ø 300 Ø 300 Ø

SECTION
https://www.youtube.com/watch?v=rendnJth8eE&list=PLkqoTjOQIev4ehjLWuKBktp4YJDBIk4lS&index=14