CONSTRUCTION (PVT) LTD Section- Retaining Wall 450 ᶲ Pile Sheet no./rev.
1 Pile Group
Bending Check Check for Punching Shear Check for Vertical Line Shear
Pile Capacity (Working Load) = 179 kN Column Perimeter = 750 mm (Get minimum Column Dimension)
268.5 kN Vmax = 1.12 N/mm2
Ultimate Load on Pile (1.5*Working
Load) = .8(fcu)^.5 = 4.38 N/mm2
Mult = 20.14 kNm Vallow = 4.38 N/mm2
b= 750 mm Punching Shear OK Shear Stress (v=V/bd) 1.12 N/mm2
d= 319 mm (100As/bd)1/3 = 0.69
M/bd2 = 0.26 Check for Vertical Line Shear (400/d)1/4 = 1.058199
100As/bd = 0.132 (From Charts) 1/rm = 0.8
As Req = 316 mm2 Shear Not Critical (fcu/25)1/3 = 1.06
As pro = 792 mm2
Hence Provide 7 T 12 (BW Top and Bottom) Design Concrete Shear 0.49 N/mm2
Shear Not OK : Increase Depth
Horizantal Binders
25% of Main R/F = 78.95 mm2
Hence provide 393 mm2 (5 T 10)
Sanken
Project- Job Ref.
Toyota Wattala Service Center
Input Data :
Pile Diameter 750 mm
Length (b) 3300 mm
Height (L) 3000 mm
S 2250 mm
Width (W1,W2) 750 mm
bv 750 mm
Depth 1400 mm
e 150 mm
Eccentricity (ex) 0 mm
Main Bar Dia. 25 mm
Cover 75 mm
Working Load (Axial) 2359 kN
Factored Load 3538.5 kN S=2.5ᶲ av
Fcu 30 N/mm2
X 750 mm
Check for Punching Shear Check Vertical Line Shear Distribution Steel
Loaded perimeter = 800 mm av=(S/(3)^.5)-(ᶲ/2)+(ᶲ/5)-(x/2)= 699.04 mm 100As/bd = 0.13
V max = 3.37 N/mm2 V (at critical) = Factored Load/3= 1180 kN As = 1706.25 mm2/m
.8*(fcu)^.5 4.38 N/mm2 v =V/bd = 1.20 N/mm2 As Pro = 565 mm2/m
V allow = 4.38 N/mm2 100As/bd = 0.25 Hence Provide T12 @ 200
Punching shear OK 400/d = 1.00
1/rm = 0.8 Horizantal Binders
(fcu/25) = 1.2 Use 25% main Steel
Vc = 0.42 N/mm2 As = 421.0395
2d/av = 3.76 As Prov = 452 mm2
Hence Provide 4 T 12
Enhanced Vc = 1.59 N/mm2
Shear OK-R/F Not required