Pile Dead Load (Ton)


ID Nos. Length At Col. Pilecap Soil
(ft) Support Length (ft) Width (ft) Thickness (ft) Weight (Ton) Soil Depth (ft)
C-1 5 62 7.5 3.5 2.5 5 5
C-2 37 128 7.5 3.5 2.5 5 5
C-3 30 243 7.5 7.5 2.5 10 5

75
Live Total Allowable Required Provided Total Pile
Soil Total Dead Load Load Pile Capacity Piles Piles Summary
Load (Ton) (Ton) (Ton) (Ton) (Nos.) (Nos.)
Weight (Ton)
8 75 31 106 113 0.94 2
8 141 70 211 113 1.87 2
16 269 140 409 113 3.62 4
204 Nos.

15,300 rft

33,380 cft
Diameter of Pile tip, d= 20.00 in Borehole Point ID
Diameter of Pile surface, D= 20.00 in BH-1
Pile Level= 75.00 ft BH-2
Bearing Stratam, Lb= 20.00 ft BH-3
FS= 3 BH-4
Minimum Allowable Capacity= 113.00 Ton BH-5
Average Allowable Capacity= 184.27 Ton BH-6
MAximum Allowable Capacity= 285.00 Ton BH-7
Standard Deviation= 58.56 Ton BH-8
BH-9
BH-10
BH-11
BH-12
BH-13
BH-14
BH-15
BH-16
BH-17
BH-18
BH-19
BH-20
BH-21
BH-22
BH-23
BH-24
BH-25
BH-26
BH-27
BH-28
Soil Test Done (Y/N) Allowable Capacity (Ton)
Y 169
Y 134
Y 126
Y 140
Y 128
N
Y 127
Y 148
Y 182
Y 144
N
Y 150
Y 262
Y 258
Y 198
Y 126
Y 166
Y 125
Y 253
Y 181
Y 228
Y 297
Y 244
Y 253
Y 241
Y 277
Y 266
Y 280
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 50.6 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 4048 KN 35 40
Ultimate Capacity= 4969.6 KN 40 45
FS= 3 45 50
Allowable Capacity= 1656.53 KN 50 55
= 169 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90 100
5 2.4 12 5
8 2.4 19.2 10
11 2.4 26.4 15
11 2.4 26.4 20
13 2.4 31.2 25
15 2.4 36
30
19 2.4 45.6
35
21 2.4 50.4
40
26 2.4 62.4
45
30 2.4 72
50
35 2.4 84
55
37 2.4 88.8
60
46 2.4 110.4
65
51 2.4 122.4
70
56 2.4 134.4
75
63 2.4 151.2
70 2.4 168 80

73 2.4 175.2 85

85 2.4 204 90
88 2.4 211.2 95
50.6 Total 1831.2 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 40.2 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 3216 KN 35 40
Ultimate Capacity= 3936 KN 40 45
FS= 3 45 50
Allowable Capacity= 1312 KN 50 55
= 134 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90
5 2.4 12 5
8 2.4 19.2 10
9 2.4 21.6 15
11 2.4 26.4 20
5 2.4 12 25
10 2.4 24
30
13 2.4 31.2
35
17 2.4 40.8
40
21 2.4 50.4
45
23 2.4 55.2
50
29 2.4 69.6
55
31 2.4 74.4
60
34 2.4 81.6
65
39 2.4 93.6
70
45 2.4 108
75
52 2.4 124.8
59 2.4 141.6 80

63 2.4 151.2 85

74 2.4 177.6 90
82 2.4 196.8 95
40.2 Total 1512 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 38.2 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 3056 KN 35 40
Ultimate Capacity= 3689.6 KN 40 45
FS= 3 45 50
Allowable Capacity= 1229.87 KN 50 55
= 126 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90
3 2.4 7.2 5
6 2.4 14.4 10
9 2.4 21.6 15
11 2.4 26.4 20
7 2.4 16.8 25
6 2.4 14.4
30
11 2.4 26.4
35
13 2.4 31.2
40
15 2.4 36
45
19 2.4 45.6
50
23 2.4 55.2
55
27 2.4 64.8
60
32 2.4 76.8
65
37 2.4 88.8
70
45 2.4 108
75
50 2.4 120
57 2.4 136.8 80

68 2.4 163.2 85

79 2.4 189.6 90
85 2.4 204 95
38.2 Total 1447.2 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 41.8 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 3344 KN 35 40
Ultimate Capacity= 4112 KN 40 45
FS= 3 45 50
Allowable Capacity= 1370.67 KN 50 55
= 140 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90
3 2.4 7.2 5
7 2.4 16.8 10
10 2.4 24 15
11 2.4 26.4 20
13 2.4 31.2 25
15 2.4 36
30
7 2.4 16.8
35
17 2.4 40.8
40
19 2.4 45.6
45
29 2.4 69.6
50
33 2.4 79.2
55
37 2.4 88.8
60
29 2.4 69.6
65
42 2.4 100.8
70
48 2.4 115.2
75
53 2.4 127.2
53 2.4 127.2 80

59 2.4 141.6 85

68 2.4 163.2 90
79 2.4 189.6 95
41.8 Total 1516.8 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 38.2 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 3056 KN 35 40
Ultimate Capacity= 3759.2 KN 40 45
FS= 3 45 50
Allowable Capacity= 1253.07 KN 50 55
= 128 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90
4 2.4 9.6 5
8 2.4 19.2 10
9 2.4 21.6 15
11 2.4 26.4 20
7 2.4 16.8 25
10 2.4 24
30
13 2.4 31.2
35
15 2.4 36
40
17 2.4 40.8
45
27 2.4 64.8
50
29 2.4 69.6
55
31 2.4 74.4
60
33 2.4 79.2
65
37 2.4 88.8
70
42 2.4 100.8
75
48 2.4 115.2
51 2.4 122.4 80

57 2.4 136.8 85

65 2.4 156 90
77 2.4 184.8 95
38.2 Total 1418.4 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 34 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 2720 KN 35 40
Ultimate Capacity= 3387.2 KN 40 45
FS= 3 45 50
Allowable Capacity= 1129.07 KN 50 55
= 116 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80
4 2.4 9.6 5
7 2.4 16.8 10
11 2.4 26.4 15
13 2.4 31.2 20
17 2.4 40.8 25
6 2.4 14.4
30
11 2.4 26.4
35
14 2.4 33.6
40
17 2.4 40.8
45
24 2.4 57.6
50
25 2.4 60
55
29 2.4 69.6
60
31 2.4 74.4
65
32 2.4 76.8
70
37 2.4 88.8
75
41 2.4 98.4
44 2.4 105.6 80

48 2.4 115.2 85

54 2.4 129.6 90
67 2.4 160.8 95
34 Total 1276.8 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 37 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 2960 KN 35 40
Ultimate Capacity= 3723.2 KN 40 45
FS= 3 45 50
Allowable Capacity= 1241.07 KN 50 55
= 127 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70
4 2.4 9.6 5
8 2.4 19.2 10
11 2.4 26.4 15
10 2.4 24 20
7 2.4 16.8 25
12 2.4 28.8
30
15 2.4 36
35
20 2.4 48
40
27 2.4 64.8
45
29 2.4 69.6
50
31 2.4 74.4
55
35 2.4 84
60
39 2.4 93.6
65
33 2.4 79.2
70
37 2.4 88.8
75
41 2.4 98.4
45 2.4 108 80

49 2.4 117.6 85

53 2.4 127.2 90
64 2.4 153.6 95
37 Total 1368 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 43.8 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 3504 KN 35 40
Ultimate Capacity= 4339.2 KN 40 45
FS= 3 45 50
Allowable Capacity= 1446.4 KN 50 55
= 148 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80
3 2.4 7.2 5
7 2.4 16.8 10
9 2.4 21.6 15
13 2.4 31.2 20
17 2.4 40.8 25
22 2.4 52.8
30
6 2.4 14.4
35
20 2.4 48
40
25 2.4 60
45
29 2.4 69.6
50
33 2.4 79.2
55
37 2.4 88.8
60
39 2.4 93.6
65
42 2.4 100.8
70
46 2.4 110.4
75
55 2.4 132
63 2.4 151.2 80

70 2.4 168 85

67 2.4 160.8 90
76 2.4 182.4 95
43.8 Total 1629.6 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 54 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 4320 KN 35 40
Ultimate Capacity= 5335.2 KN 40 45
FS= 3 45 50
Allowable Capacity= 1778.4 KN 50 55
= 182 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90 100
4 2.4 9.6 5
6 2.4 14.4 10
8 2.4 19.2 15
10 2.4 24 20
22 2.4 52.8 25
21 2.4 50.4
30
27 2.4 64.8
35
11 2.4 26.4
40
13 2.4 31.2
45
28 2.4 67.2
50
22 2.4 52.8
55
85 2.4 204
60
90 2.4 216
65
55 2.4 132
70
21 2.4 50.4
75
19 2.4 45.6
95 2.4 228 80

78 2.4 187.2 85

45 2.4 108 90
54 2.4 129.6 95
54 Total 1713.6 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 42.6 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 3408 KN 35 40
Ultimate Capacity= 4214.4 KN 40 45
FS= 3 45 50
Allowable Capacity= 1404.8 KN 50 55
= 144 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80
3 2.4 7.2 5
9 2.4 21.6 10
13 2.4 31.2 15
13 2.4 31.2 20
8 2.4 19.2 25
6 2.4 14.4
30
15 2.4 36
35
17 2.4 40.8
40
27 2.4 64.8
45
29 2.4 69.6
50
33 2.4 79.2
55
37 2.4 88.8
60
38 2.4 91.2
65
41 2.4 98.4
70
47 2.4 112.8
75
50 2.4 120
53 2.4 127.2 80

57 2.4 136.8 85

60 2.4 144 90
71 2.4 170.4 95
42.6 Total 1504.8 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 32.8 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 2624 KN 35 40
Ultimate Capacity= 3178.4 KN 40 45
FS= 3 45 50
Allowable Capacity= 1059.47 KN 50 55
= 109 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80
3 2.4 7.2 5
7 2.4 16.8 10
10 2.4 24 15
11 2.4 26.4 20
8 2.4 19.2 25
7 2.4 16.8
30
9 2.4 21.6
35
11 2.4 26.4
40
13 2.4 31.2
45
15 2.4 36
50
16 2.4 38.4
55
20 2.4 48
60
26 2.4 62.4
65
34 2.4 81.6
70
41 2.4 98.4
75
43 2.4 103.2
55 2.4 132 80

69 2.4 165.6 85

70 2.4 168 90
74 2.4 177.6 95
32.8 Total 1300.8 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 45.2 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 3616 KN 35 40
Ultimate Capacity= 4405.6 KN 40 45
FS= 3 45 50
Allowable Capacity= 1468.53 KN 50 55
= 150 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90
4 2.4 9.6 5
9 2.4 21.6 10
10 2.4 24 15
13 2.4 31.2 20
16 2.4 38.4 25
7 2.4 16.8
30
9 2.4 21.6
35
15 2.4 36
40
19 2.4 45.6
45
24 2.4 57.6
50
32 2.4 76.8
55
37 2.4 88.8
60
39 2.4 93.6
65
47 2.4 112.8
70
48 2.4 115.2
75
55 2.4 132
56 2.4 134.4 80

61 2.4 146.4 85

73 2.4 175.2 90
77 2.4 184.8 95
45.2 Total 1562.4 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 75.8 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 6064 KN 35 40
Ultimate Capacity= 7688.8 KN 40 45
FS= 3 45 50
Allowable Capacity= 2562.93 KN 50 55
= 262 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90 100
5 2.4 12 5
7 2.4 16.8 10
9 2.4 21.6 15
12 2.4 28.8 20
15 2.4 36 25
19 2.4 45.6
30
51 2.4 122.4
35
50 2.4 120
40
70 2.4 168
45
60 2.4 144
50
70 2.4 168
55
80 2.4 192
60
80 2.4 192
65
90 2.4 216
70
59 2.4 141.6
75
70 2.4 168
85 2.4 204 80

91 2.4 218.4 85

91 2.4 218.4 90
90 2.4 216 95
75.8 Total 2649.6 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 73 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 5840 KN 35 40
Ultimate Capacity= 7570.4 KN 40 45
FS= 3 45 50
Allowable Capacity= 2523.47 KN 50 55
= 258 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90 100
9 2.4 21.6 5
15 2.4 36 10
13 2.4 31.2 15
11 2.4 26.4 20
15 2.4 36 25
28 2.4 67.2
30
50 2.4 120
35
65 2.4 156
40
55 2.4 132
45
70 2.4 168
50
80 2.4 192
55
70 2.4 168
60
80 2.4 192
65
90 2.4 216
70
70 2.4 168
75
55 2.4 132
70 2.4 168 80

75 2.4 180 85

80 2.4 192 90
95 2.4 228 95
73 Total 2630.4 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 58.6 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 4688 KN 35 40
Ultimate Capacity= 5806.4 KN 40 45
FS= 3 45 50
Allowable Capacity= 1935.47 KN 50 55
= 198 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80
5 2.4 12 5
2 2.4 4.8 10
6 2.4 14.4 15
6 2.4 14.4 20
12 2.4 28.8 25
20 2.4 48
30
25 2.4 60
35
26 2.4 62.4
40
44 2.4 105.6
45
46 2.4 110.4
50
47 2.4 112.8
55
49 2.4 117.6
60
52 2.4 124.8
65
62 2.4 148.8
70
64 2.4 153.6
75
66 2.4 158.4
69 2.4 165.6 80

69 2.4 165.6 85

73 2.4 175.2 90
75 2.4 180 95
58.6 Total 1963.2 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 37.4 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 2992 KN 35 40
Ultimate Capacity= 3697.6 KN 40 45
FS= 3 45 50
Allowable Capacity= 1232.53 KN 50 55
= 126 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80
4 2.4 9.6 5
7 2.4 16.8 10
10 2.4 24 15
11 2.4 26.4 20
15 2.4 36 25
7 2.4 16.8
30
5 2.4 12
35
13 2.4 31.2
40
17 2.4 40.8
45
30 2.4 72
50
29 2.4 69.6
55
33 2.4 79.2
60
37 2.4 88.8
65
37 2.4 88.8
70
39 2.4 93.6
75
41 2.4 98.4
45 2.4 108 80

54 2.4 129.6 85

55 2.4 132 90
75 2.4 180 95
37.4 Total 1353.6 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 50.4 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 4032 KN 35 40
Ultimate Capacity= 4876.8 KN 40 45
FS= 3 45 50
Allowable Capacity= 1625.6 KN 50 55
= 166 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90
5 2.4 12 5
6 2.4 14.4 10
8 2.4 19.2 15
11 2.4 26.4 20
10 2.4 24 25
13 2.4 31.2
30
5 2.4 12
35
18 2.4 43.2
40
13 2.4 31.2
45
29 2.4 69.6
50
30 2.4 72
55
53 2.4 127.2
60
30 2.4 72
65
58 2.4 139.2
70
63 2.4 151.2
75
48 2.4 115.2
77 2.4 184.8 80

56 2.4 134.4 85

47 2.4 112.8 90
85 2.4 204 95
50.4 Total 1596 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 36 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 2880 KN 35 40
Ultimate Capacity= 3669.6 KN 40 45
FS= 3 45 50
Allowable Capacity= 1223.2 KN 50 55
= 125 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 20 40 60 80 100 120
5 2.4 12 5
8 2.4 19.2 10
11 2.4 26.4 15
13 2.4 31.2 20
17 2.4 40.8 25
15 2.4 36
30
14 2.4 33.6
35
23 2.4 55.2
40
25 2.4 60
45
29 2.4 69.6
50
30 2.4 72
55
26 2.4 62.4
60
34 2.4 81.6
65
45 2.4 108
70
34 2.4 81.6
75
41 2.4 98.4
71 2.4 170.4 80

75 2.4 180 85

55 2.4 132 90
99 2.4 237.6 95
36 Total 1608 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 75.4 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 6032 KN 35 40
Ultimate Capacity= 7426.4 KN 40 45
FS= 3 45 50
Allowable Capacity= 2475.47 KN 50 55
= 253 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 20 40 60 80 100 120
7 2.4 16.8 5
5 2.4 12 10
9 2.4 21.6 15
11 2.4 26.4 20
12 2.4 28.8 25
16 2.4 38.4
30
21 2.4 50.4
35
35 2.4 84
40
45 2.4 108
45
55 2.4 132
50
61 2.4 146.4
55
58 2.4 139.2
60
75 2.4 180
65
82 2.4 196.8
70
89 2.4 213.6
75
73 2.4 175.2
99 2.4 237.6 80

89 2.4 213.6 85

91 2.4 218.4 90
94 2.4 225.6 95
75.4 Total 2464.8 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 55.2 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 4416 KN 35 40
Ultimate Capacity= 5313.6 KN 40 45
FS= 3 45 50
Allowable Capacity= 1771.2 KN 50 55
= 181 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 20 40 60 80 100 120
5 2.4 12 5
9 2.4 21.6 10
7 2.4 16.8 15
14 2.4 33.6 20
17 2.4 40.8 25
18 2.4 43.2
30
19 2.4 45.6
35
28 2.4 67.2
40
15 2.4 36
45
25 2.4 60
50
27 2.4 64.8
55
33 2.4 79.2
60
45 2.4 108
65
54 2.4 129.6
70
58 2.4 139.2
75
86 2.4 206.4
95 2.4 228 80

85 2.4 204 85

98 2.4 235.2 90
95 2.4 228 95
55.2 Total 1999.2 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 68.6 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 5488 KN 35 40
Ultimate Capacity= 6692.8 KN 40 45
FS= 3 45 50
Allowable Capacity= 2230.93 KN 50 55
= 228 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90 100
11 2.4 26.4 5
9 2.4 21.6 10
15 2.4 36 15
17 2.4 40.8 20
15 2.4 36 25
21 2.4 50.4
30
29 2.4 69.6
35
45 2.4 108
40
55 2.4 132
45
18 2.4 43.2
50
19 2.4 45.6
55
33 2.4 79.2
60
65 2.4 156
65
65 2.4 156
70
85 2.4 204
75
95 2.4 228
91 2.4 218.4 80

82 2.4 196.8 85

92 2.4 220.8 90
90 2.4 216 95
68.6 Total 2284.8 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 88.6 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 7088 KN 35 40
Ultimate Capacity= 8734.4 KN 40 45
FS= 3 45 50
Allowable Capacity= 2911.47 KN 50 55
= 297 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 20 40 60 80 100 120
6 2.4 14.4 5
7 2.4 16.8 10
11 2.4 26.4 15
9 2.4 21.6 20
12 2.4 28.8 25
15 2.4 36
30
19 2.4 45.6
35
45 2.4 108
40
55 2.4 132
45
70 2.4 168
50
81 2.4 194.4
55
85 2.4 204
60
91 2.4 218.4
65
90 2.4 216
70
90 2.4 216
75
87 2.4 208.8
75 2.4 180 80

90 2.4 216 85

95 2.4 228 90
96 2.4 230.4 95
88.6 Total 2709.6 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 71.2 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 5696 KN 35 40
Ultimate Capacity= 7157.6 KN 40 45
FS= 3 45 50
Allowable Capacity= 2385.87 KN 50 55
= 244 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90 100
5 2.4 12 5
7 2.4 16.8 10
9 2.4 21.6 15
11 2.4 26.4 20
13 2.4 31.2 25
19 2.4 45.6
30
45 2.4 108
35
55 2.4 132
40
63 2.4 151.2
45
67 2.4 160.8
50
39 2.4 93.6
55
81 2.4 194.4
60
65 2.4 156
65
85 2.4 204
70
45 2.4 108
75
80 2.4 192
90 2.4 216 80

85 2.4 204 85

75 2.4 180 90
95 2.4 228 95
71.2 Total 2481.6 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 76 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 6080 KN 35 40
Ultimate Capacity= 7426.4 KN 40 45
FS= 3 45 50
Allowable Capacity= 2475.47 KN 50 55
= 253 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90
5 2.4 12 5
9 2.4 21.6 10
11 2.4 26.4 15
13 2.4 31.2 20
17 2.4 40.8 25
15 2.4 36
30
15 2.4 36
35
21 2.4 50.4
40
42 2.4 100.8
45
55 2.4 132
50
63 2.4 151.2
55
70 2.4 168
60
80 2.4 192
65
70 2.4 168
70
75 2.4 180
75
85 2.4 204
64 2.4 153.6 80

81 2.4 194.4 85

83 2.4 199.2 90
85 2.4 204 95
76 Total 2301.6 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 69.4 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 5552 KN 35 40
Ultimate Capacity= 7076 KN 40 45
FS= 3 45 50
Allowable Capacity= 2358.67 KN 50 55
= 241 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90 100
7 2.4 16.8 5
7 2.4 16.8 10
12 2.4 28.8 15
13 2.4 31.2 20
19 2.4 45.6 25
21 2.4 50.4
30
42 2.4 100.8
35
47 2.4 112.8
40
55 2.4 132
45
65 2.4 156
50
75 2.4 180
55
55 2.4 132
60
65 2.4 156
65
67 2.4 160.8
70
85 2.4 204
75
75 2.4 180
55 2.4 132 80

70 2.4 168 85

80 2.4 192 90
95 2.4 228 95
69.4 Total 2424 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 78.8 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 6304 KN 35 40
Ultimate Capacity= 8125.6 KN 40 45
FS= 3 45 50
Allowable Capacity= 2708.53 KN 50 55
= 277 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90 100
7 2.4 16.8 5
15 2.4 36 10
17 2.4 40.8 15
19 2.4 45.6 20
18 2.4 43.2 25
42 2.4 100.8
30
60 2.4 144
35
55 2.4 132
40
47 2.4 112.8
45
65 2.4 156
50
75 2.4 180
55
82 2.4 196.8
60
87 2.4 208.8
65
95 2.4 228
70
75 2.4 180
75
55 2.4 132
80 2.4 192 80

90 2.4 216 85

90 2.4 216 90
91 2.4 218.4 95
78.8 Total 2796 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 74.4 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 5952 KN 35 40
Ultimate Capacity= 7797.6 KN 40 45
FS= 3 45 50
Allowable Capacity= 2599.2 KN 50 55
= 266 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90 100
9 2.4 21.6 5
13 2.4 31.2 10
17 2.4 40.8 15
35 2.4 84 20
55 2.4 132 25
49 2.4 117.6
30
49 2.4 117.6
35
65 2.4 156
40
55 2.4 132
45
63 2.4 151.2
50
55 2.4 132
55
60 2.4 144
60
80 2.4 192
65
85 2.4 204
70
79 2.4 189.6
75
68 2.4 163.2
75 2.4 180 80

90 2.4 216 85

92 2.4 220.8 90
95 2.4 228 95
74.4 Total 2853.6 100
Meyerhof's Method for estimating End Bearing & Skin Resistence
Diameter of Pile tip, d= 0.5 m From, ft Upto, ft
Diameter of Pile surface, D= 0.5 m 0 5
Pile Level= 75 ft 5 10
Upper Level= 58.3333333333333 ft 10 15
Bottom Level= 81.6666666666667 ft 15 20
Area of Pile Tip, Ap = 0.2 m2 20 25
Average N- Value or SPT= 85.4 Nos. 25 30
Bearing Stratam, Lb= 6.1 m 30 35
End bearing = 6832 KN 35 40
Ultimate Capacity= 8236 KN 40 45
FS= 3 45 50
Allowable Capacity= 2745.33 KN 50 55
= 280 Ton 55 60
60 65
65 70
70 75
75 80
80 85
85 90
90 95
95 100
Average N- value =
nd Bearing & Skin Resistence
N- Value of SPT Surface Area, m2 Skin resistance, KN 0 10 20 30 40 50 60 70 80 90 100
6 2.4 14.4 5
10 2.4 24 10
8 2.4 19.2 15
7 2.4 16.8 20
9 2.4 21.6 25
13 2.4 31.2
30
18 2.4 43.2
35
17 2.4 40.8
40
30 2.4 72
45
50 2.4 120
50
70 2.4 168
55
87 2.4 208.8
60
85 2.4 204
65
95 2.4 228
70
80 2.4 192
75
80 2.4 192
55 2.4 132 80

70 2.4 168 85

80 2.4 192 90
90 2.4 216 95
85.4 Total 2304 100

You might also like