Maximum Axial load from staad, Fy = 211 KN (factored)
As per soil report,the capacity of under reamed piles were as listed below
DEPTH SAFE LOAD CARRYING
S.NO SIZE OF THE PILE BELOW CAP CAPACITY
1 300 mm Double Under Reamed Pile 4.00 meters 12 Tonnes
2 380 mm Double Under Reamed Pile 4.00 meters 18 Tonnes 3 300 mm Double Under Reamed Pile 4.50 meters 14 Tonnes 4 380 mm Double Under Reamed Pile 4.50 meters 20 Tonnes 5 300 mm Double Under Reamed Pile 5.00 meters 16 Tonnes 6 380 mm Double Under Reamed Pile 5.00 meters 22 Tonnes
From the above list,Considering 380 mm dia. Pile,
Capacity of 380 Dia.pile at depth 5.00meters ,Pu = 22 Ton 220 KN (Pu > Fy) Hence Safe Double Under reamed Pile specifications As per IS2911-2010(part-3) and soil report Specifications Dia. of stem, D = 380 mm Dia. of bulb, Du = 950 mm (2.5xD) No. of bulbs = 2 No's Thickness of bulb = 100 mm (1/4th D) Depth of top bulb from EGL = 1750 mm Spacing between bulbs = 1425 mm (1.5xDu) Length of bottom bulb from toe = 1.825 mm (Bucket length) Side Cover for pile = 50 mm Bottom cover = 75 mm Longitudinal reinforcement Required = 453.416 mm2 (0.4% c/s area for HYSDbars) Provided reinforcement = 8 T-12 Provided reinforcement = 904.32 mm2 Hence Safe