You are on page 1of 1

DESIGN OF PILE FOUNDATION

Maximum Axial load from staad, Fy = 211 KN (factored)


As per soil report,the capacity of under reamed piles were as listed below

DEPTH SAFE LOAD CARRYING


S.NO SIZE OF THE PILE
BELOW CAP CAPACITY

1 300 mm Double Under Reamed Pile 4.00 meters 12 Tonnes


2 380 mm Double Under Reamed Pile 4.00 meters 18 Tonnes
3 300 mm Double Under Reamed Pile 4.50 meters 14 Tonnes
4 380 mm Double Under Reamed Pile 4.50 meters 20 Tonnes
5 300 mm Double Under Reamed Pile 5.00 meters 16 Tonnes
6 380 mm Double Under Reamed Pile 5.00 meters 22 Tonnes

From the above list,Considering 380 mm dia. Pile,


Capacity of 380 Dia.pile at depth 5.00meters ,Pu = 22 Ton
220 KN (Pu > Fy)
Hence Safe
Double Under reamed Pile specifications
As per IS2911-2010(part-3) and soil report Specifications
Dia. of stem, D = 380 mm
Dia. of bulb, Du = 950 mm (2.5xD)
No. of bulbs = 2 No's
Thickness of bulb = 100 mm (1/4th D)
Depth of top bulb from EGL = 1750 mm
Spacing between bulbs = 1425 mm (1.5xDu)
Length of bottom bulb from toe = 1.825 mm (Bucket length)
Side Cover for pile = 50 mm
Bottom cover = 75 mm
Longitudinal reinforcement Required = 453.416 mm2 (0.4% c/s area for HYSDbars)
Provided reinforcement = 8 T-12
Provided reinforcement = 904.32 mm2 Hence Safe