You are on page 1of 2
Roe daucucrue a) Bead SYCON-66 XX re An180 9007 2008 Company Tar Praca Potten Pa da aca AUTOMATIC POWER FACTOR CONTROLLER This version of 8 XX saris display al parameters such as power facto, shortfall KVAR Excess KVAR , voltage, curren and THD al at atime. By seocon, it cisplays% harmonis irom 3d io 13th and capacor values. thas but in acy to cut-off the capactors incase of harmonic oeroad. nas password protected setags. ts bultin TEST mode enables tots! he panel witout CT curent Auto 3s wel as Manua mode of operation ar avaliable in hs ely CONTROL FEATURES Large alphanumeric LCD display 2x 16 characters) LED indcaon or capacitor ON OFF status TCENERAL FEATURES | intatigant KVAR based switching © Frianaly user interface = Easy install * Large alpha-numeric display * Avaltiein 4 18 stages (alate stages 46 8.12,.1416) ‘© Number of stages can ba confgued at site PEGs + Power factor / Votage current © ShortellKVAR / Excess KVAR THO © LED indication of capac ONOFF status + Selectable eto “3th harmonies © Capacitor Values = Setings Voltage input A1SVAC 15% — Low eurent ‘current Input Switching Contact -11A(optional) Accuracy Frequency soz ‘Switching Interval Over Voltage Release <7OVAG +I: 1% Switching Program era dees \, 1% (60m) ‘0Aat250V AC lass 1 5to 1200 sec Intetigent (Best ft) * assed pti stings {Sosa CT ta om 650 = RAR nag aa Sage © cTratio \ o Setting iy Sock tne per ON + Homan) Orta peo « Caco senmecton meat Lovano . bvervtape \ historian canal eegcteapatrvaves Maral swt cy Sma D. ‘OPTIONAL! ars ‘© 3 Phase sensing CT) contol for unbalanced load system * tsecewitin ly «© Dual sings for Generator and EB Power factor ‘© HTCT sensing for HT applications CET 148 L) x 148 9 x80 (2) mm 198 mmx 138 mm 18k Dimensions DE aiS Sree =o Aniso 2001-2008 Company ve areas Pe ror Pate a aia AUTOMATIC POWER FACTOR CONTROLLER This advance version n 68 seres wih smal volume and ght weight cspiays al parameters lke system power fcr, voltage, curek, system KVA, system KVAK, systom KW, shortfall KVAr, THD, Itworkson smart itching algortm where a number of capacitors canbe tumed ON or OFF islananeously used onthe capacitve KVArrequitoment. Itais displays harmonics from 3dto 13th. thas capably to auto - deny the capactor values. lhe stings are password protacted Ithasin- bulk capacitor protactonsystm incase of hammoicoveroad and over otage. Win - bit TEST mode, the panel canbe tested wibou CT current Large alphanumeric LCD display (2 16 characters) Pwer factor Capactor stages ON Discharging capacitors Votage, cutent KWAVAIKVAR Shorfall or Excess KVAR S6THD J Selectable display of 3rd to. 13th harmonics Selectable display of capacitor values: Display of stings Display of alarm message ‘Maliple capacitor switching facility “© Intligent with best corral Available in 4 to 16 slagos (avalableslagos 4 6 8,12,"4,16) Menu driven user endl handing Alarm output Easy tonsil 485 port (optona Voltage input AISVACS15% Switching contact ‘Current input 15h ‘Switching interval, JA optional) Switching Frequency solze5te Stages Over voltage roleaso 47oval% Accuracy Low current 1% (60ma) Target PF Mode Under compensation Over compensato Uneercaert Over vatage Excess Talal harris distorian (THD N Pesevad acto sas Adjustable %KVAR switching capacity Asta vale oe PF Auster om 180 tii ee is Nb Node avalible n 68,214.18 eps, ° ‘Adjustable settings for % THD (Total harmonic distortion) protection _ Disconnedton incase of low cuent Adjustable numer of maximum stages. Adjustable lack time fr power ON Auto dentfcaton or Manual feeding of capacitor values Neanual switching facity Test mode falty ‘s0Amp at 2500 Dimension ‘44m «144mm x 8Omn(D) 101200 sec Panel cutout 438 mm X 138 mm Mosintligent (Best Fe) Weight 16 Ka 4,6,8, 12, 14,16 Ve (etagi) 071 Lag o 0.80 Lead AvtoManval Note: Dano coraus develmerct prot sont ay Cane.

You might also like