Professional Documents
Culture Documents
EQUIPMENT
FOR AGGRESSIVE
GASES SINGLE UNITS
VACUUM REGULATORS
ROTAMETERS
DIFFERENTIAL PRESSURE REGULATORS
EJECTORS
MOTOR DRIVEN RATE VALVE
VACUUM SWITCHOVER
CHLORINE GAS FILTERS
PRESSURE REDUCING VALVE
EVAPORATORS
6
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
V
M 20 C
series
Rate Valves:
Rate Valves are made of high
quality materials.
BUL00007
7
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Vacuum regulators M 20 C
ORDER CODES
M 20 A C / V X M F
Model
El. Alarm Signal (Full/Empty )
Gas type
Rate Valve
Dosing range
Pressure Gauge
Connec on Yoke
OPTIONS:
- Alarm: yes “A” , without alarm the le er is not wri en in
- Gas type: “C” - Cl2, “S” - SO2, “N” - NH3
- Rate Valve: yes “V” , without it the le er is not wri en in
- Dosing range*: is chosen from technical data table below, and the
suitable number is wri en into the ordering code
- Pressure gauge yes -“M” , without it the le er is not wri en in
- Yoke - standard nut is included; for clamp type the le er “F” is wri en in the code
TECHNICAL DATA Dosing Range( X)* : (in g/h) Gas types : Accuracy :
1 up to 12 C=Cl2 Within 4% of flow
2 up to 25 S=SO2
3 up to 100 N=NH3 Opera ng range :
4 up to 200 20 : 1
5 up to 500 Weight :
6 up to 1000 3.10 kg
7 up to 2000
8 up to 4000
9 up to 10000
15 up to 15000
Connec ons
Vacuum: Connec on to the Cylinder : Other connec ons on
1-7 (2 kg/h) – d8/d10 Standard : request!
8 (4 kg/h) – d8/d10 1” (according DIN 477)
*more than 30 m – d12/d16 Op onally:
9 (10 kg/h) – d12/d16 1.030” (CGA)
15 (15 kg/h) – d12/d16 5/8” (BSP)
M27x1,5mm
MEASURE DRAWINGS
BUL00007
8 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
V
M 40 C
series
BUL00008
9
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Vacuum regulators M 40 C
ORDER CODES
M 40 C/ X M F T H
Model
Gas type
Dosing range
Pressure Gauge
Filter
Drip-leg
Heater
OPTIONS:
-Gas type: “C” - Cl2, “S” - SO2, “N” - NH3
-Dosing range*: is chosen from technical data table below and the
suitable number is wri en into the ordering code
-Pressure gauge : yes “M” , without it the le er is not wri en in
-Filter: yes “F”; if selected, then drip-leg “T” and heater “H” can’t be present
-Drip-leg: yes “T”, without it the le er is not wri en in
-Heater: yes “H”; it can only be wri en in if the drip-leg is present
TECHNICAL DATA
Dosing Range(X)* : (in kg/h) Gas types : Accuracy :
20 up to 20 C=Cl2 Within 4% of flow
40 up to 40 S=SO2
N=NH3 Opera ng range :
20 : 1
Weight :
19 kg
Dimensions:
M 40: 673 x 395 x 179 mm
Connec ons
Vacuum: Pressure: Other connec ons on
20 (20 kg/h) – d20 – 3/4" Flange connec on D3/4’’ request!
40 (40 kg/h) – d25 – 1" NP16 DN20 (DIN2633)
Op onally: from 20 up to 40 kg
d32
d40
MEASURE DRAWINGS
BUL00008
10 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
V
M 50 C
series
The capacity of the M 50 C vacuum regulator is up to
200 kg/h.
BUL00009
11
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Vacuum regulators M 50 C
ORDER CODES
M 50 C/ X M F T H
Model
Gas type
Dosing range
Pressure Gauge
Filter
Drip-leg
Heater
OPTIONS:
-Gas type: “C” - Cl2, “S” - SO2, “N” - NH3
-Dosing range*: is chosen from technical data table below and the
suitable number is wri en into the ordering code
-Pressure gauge : yes “M” , without it the le er is not wri en in
-Filter: yes “F” ; if selected, then drip-leg “T” and heater “H” can’t be present
-Drip-leg: yes “T”, without it the le er is not wri en in
-Heater: yes “H”; can only be wri en in if the drip-leg is present
TECHNICAL DATA
Dosing Range(X)* : (in kg/h) Gas types : Accuracy :
60 up to 60 C=Cl2 Within 4% of flow
80 up to 80 S=SO2
120 up to 120 N=NH3 Opera ng range :
160 up to 160 20 : 1
200 up to 200
Dimensions:
M 50: 673 x 488 x 179 mm
Connec ons
Vacuum: Pressure: Other connec ons on
80 (80 kg/h) – d32 – 5/4" Flange connec on D3/4’’ request!
120 (120 kg/h) – d32 – 5/4" NP16 DN20 (DIN2633)
160 (160 kg/h) – d40 – 6/4" from 60 up to 120 kg
200 (200 kg/h) – d50 – 2"
MEASURE DRAWINGS
BUL00009
12 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
series M 30 C
GENERAL INSTALLATION
Pressure regulators M 30 C are a part of chlorina on System of pressure regulators M 30 RC is equipped
system, and are designed for direct feed of gaseous with a pressure reducing valve which prevents the
chlorine under pressure, e. g. for open swimming chlorine gas to enter under high pressure. The
pools and tanks at loca ons where it is not possible pressure is reduced to a 1,2 bar maximum. Exhaust
to provide an auxiliary power supply. should be made so that the remainig chlorine gas in
the pipline is neutralised. The diffuser should be
The M 30 C consists of : mounted at least 1,2 m below water level and
Pressure regulator maximum of 7m, because the higher the feed rate the
greater should be the depth. Because of the
The capaci es of the device vary from 0 - 2000 g/h, influences of temperature and quality of the media,
func oning on the principle of pressure in the the bubbles and other factors, always choose the
chlorine cylinder with manual feed rate adjustment. deepest point to insure best possible absorp on.
OPERATION PRINCIPLE
Chlorine gas under cylinder pressure enters the
regulator through the inlet valve, where the pressure
is reduced to 1,2 bar. The gas then flows through the
rate tube and the rate valve where the desired
amount is set. The set amount of chlorine gas goes
through the chlorine pipe and three way valve to the
diffuser, where it is mixed with water. The diffuser is
equipped with check valve to prevent the water
entering the system.
BUL00010
13
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SYSTEMS/ Pressure regulators M 30 RC
OPTIONS:
- Gas type: “C” – Cl2, “S” – SO2
- Rate Valve: by default
- Dosing range*: is chosen from technical data table below and the
suitable number is wri en into the ordering code
- Pressure gauge : by default
- Yoke - standard nut; for clamp type the le er ''F'' is wri en in the code
Connec ons
BUL00010
14 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
R
series M 200 C
Rate valves:
Rate valves are made of high
quality materials.
BUL00011
15
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Rotameters M 200 C
ORDER CODES
M 200/ X C
Model
Dosing range
Gas type
OPTIONS:
- Model: 200 for dosing range up to 15kg
240 for dosing range up to 40kg
250 for dosing range up to 200kg
- Dosing range*: is chosen from technical data table berlow and the
suitable number is wri en into the ordering code
- Gas type: “C” - Cl2, “S” - SO2, “N” - NH3
TECHNICAL DATA Dosing range M 200: (g/h) Dosing range M 240:(kg/h) Gas types :
1 up to 12 20 up to 20 C=Cl2
2 up to 25 40 up to 40 S=SO2
3 up to 100 N=NH3
4 up to 200
5 up to 500 Dosing range M 250:(kg/h) Weight :
6 up to 1000 60 up to 60 M 200: 0,3 kg
7 up to 2000 80 up to 80 M 200/9: 1 kg
8 up to 4000 120 up to 120 M 240: 5,5 kg
9 up to 10000 160 up to 160 M 250: 6 kg
15 up to 15000 200 up to 200
Connec ons
1-7 (2 kg/h) – d8/d10 20 (20 kg/h) – d20 – 3/4" Other connec ons on
8 (4 kg/h) – d8/d10 40 (40 kg/h) – d25 – 1" request!
*more than 30 m – d12/d16 60 (60kg/h) – d32—5/4
9 (10 kg/h) – d12/d16 80 (80 kg/h) – d32 – 5/4"
15 (15 kg/h) – d12/d16 120 (120 kg/h) – d32 – 5/4"
160 (160 kg/h) – d40 – 6/4"
200 (200 kg/h) – d50 – 2"
MEASURE DRAWINGS
BUL00011
16 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
D
R
series DP 20, DP 40, DP 50
BUL00012
17
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Differen al pressure Regulators DP 20, DP 40, DP 50
ORDER CODES
DP 20 C / X
Model
Gas type
Dosing range
OPTIONS:
- Model: DP 20: 2 - 10 kg/h
DP 40: 20 - 40 kg/h
DP 50: 60 - 120 kg/h
- Gas type: “C” - Cl2, “S” - SO2, “N” - NH3
- Dosing range*: is chosen from technical data table below and the
suitable number is wri en into the ordering code
TECHNICAL DATA Dosing range* DP 20: (kg/h) Dosing range DP 40:(kg/h) Gas types :
8 up to 4 20 up to 20 C=Cl2
9 up to 10 40 up to 40 S=SO2
N=NH3
Connec ons
Vacuum:
1- 2kg/h — d8/d10
2- 4kg/h — d8/d10
3- 10kg/h — d12/d16
20- 20kg/h — d20
40- 40kg/h — d25
80- 80kg/h — d40
120- 120kg/h — d50
MEASURE DRAWINGS
BUL00012
18 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
E
series M 300 C
Capacity up to 15 kg/h
BUL00013
19
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Ejectors M 300 C
OPTIONS:
- Model: M 300 - Ordinary ejector construc on for pressure up to 6 bar.
M 301 - Reinforced ejectors for pressure more than 6 bar.
M 302 - Diffuser with stone
M 303 - Ejectors with a “connec on cock” for dismantling under pressure.
M 304 - D.P.T – Ejector with PVC valves for dismantling under pressure, but
not more than 5 bar, designed for pool engineering.
M 305 - Reinforced ejectors for more than 2000g/h .
M 306 - Ejectors with union connec on.
- Dosing range*: is chosen from technical data table below and the suitable number is wri en
into the ordering code
- Membrane type : TEFLON
- Gas type : “C” - Cl2, “S” - SO2, “N” - NH3
TECHNICAL DATA Dosing range (X)*: ( in g/h) Weight: Gas types :
1 up to 200 M300/1-4: 0,6 kg C=Cl2
2 up to 500 M305/5-6: 1,2 kg S=SO2
3 up to 1000 M305/15 : 1,2 kg N=NH3
4 up to 2000 M301/1-4: 1,6 kg
5 up to 4000 M306/1-5: 0,6 kg
6 up to 10000
15 up to 15000
MEASURE DRAWINGS
BUL00013
20 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
H
series M 340 C & M 350 C
BUL00014
21
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ High capacity ejectors M 340 C & M 350 C
ORDER CODES
M 340/ X C
Model
Dosing range
Gas type
OPTIONS:
- Model: 340 for dosing range up to 40kg
350 for dosing range up to 200kg
- Dosing range*: is chosen from technical data table below and the
suitable number is wri en into the ordering code
- Gas type: “C” - Cl2, “S” - SO2, “N” - NH3
Connec ons
M 340 Water inlet - Water outlet - Vacuum connec on Op ons:
20 - DN50 (2’’) DN50 (2’’) d20/d25/d32/d40 Conec ons for
40 - DN50 (2’’) DN50 (2’’) d20/d25/d32/d40 160 and 200 kg
are subject to
M 350 Water inlet - Water outlet - Vacuum connec on specific project.
80 - DN80 (3’’) DN80 (3’’) d32/d40/d50
120 - DN80 (3’’) DN80 (3’’) d32/d40/d50 Other connec ons on
request!
MEASURE DRAWINGS
Ejector up to 40 kg/h Ejector up to 120 kg/h
BUL00014
22 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
M
series M 3521 C
ACCURATE FEED
SIMPLE INSTALLATION
MADE OF QUALITY MATERIALS
GENERAL
Electronicaly controlled electromo ve rate valve
M 3521 C is designed for accurate feed of gas
chlorine into the water.
Dosing range is from 10 gCl2/h up to 200 kgCl2/h.
BUL00015
23
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Motor rate valve M 3521 C
Dosing range
OPTIONS:
- Gas type: “C” - Cl2, other gas on request
- Dosing range*: is chosen from technical data table below and the
suitable number is wri en into the ordering code
TECHNICAL DATA Dosing range(X)*: (g/h) Dosing range(X)*: (kg/h) Gas types :
3 up to 100 20 up to 20 C=Cl2
4 up to 200 40 up to 40 S=SO2
5 up to 500 80 up to 80 N=NH3
6 up to 1000 120 up to 120
7 up to 2000 160 up to 160 Weight :
8 up to 4000 200 up to 200 2,6 kg
9 up to 10000
12 up to 12000 Dimensions :
15 up to 15000 M 3521 C: 300 x 120 x 132 mm
MEASURE DRAWINGS
BUL00015
24 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
V
series M 400 & M 440
Capaci es
up to 10kg/h & up to 120kg/h
INSTALLATION
BUL00016
25
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Vacuum switchover M 400 & M 440
OPTIONS:
- Model: 400 for dosing range up to 10kg/h
440 for dosing range up to 120kg/h
- Dosing range*: is chosen from technical data table below and the
suitable number is wri en into the ordering code
- El. Signal (indicates the source in use): yes “Y”, without it the le er is not wri en in
- Gas type: “C” - Cl2, other gas by order
Connec ons
1-Up to 4kg/h-d8/d10
2-Up to 10kg/h-d12/d16
40-Up to 40kg/h- d25/d32/d40
80-Up to 80kg/h- d40/d50
120-Up to 120kg/h- d50
MEASURE DRAWINGS
BUL00016
26 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
P S
Series M 481 C
BUL00017
27
SINGLE UNITS/ Pressure sewitcover M 481 C
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Pressure Switchover M 481 C
ORDER CODES
M 481 C / 1 X
Model
Gas Type
Capacity
OPTIONS:
- Gas type: “C” - Cl2, “S” - SO2, “N” - NH3
- No. of probes: 1 = pressure switchover with one probe
2 = pressure switchover with two probes
- Capacity : is chosen from technical data table below and the
suitable le er is wri en into the ordering code
Connec ons: Flange connec ons: Other connec ons on request!
1A = DN15
1B = DN15
2A = DN25
2B = DN25
DIMENSIONAL DRAWINGS
BUL00017
28 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
P S
Series M 470 C PVC
BUL00018
29
SINGLE UNITS/ Pressure sewitcover M 481 C
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Pressure Switchover M 470 C PVC
ORDER CODES
M 470 C / 1 X
Model
Gas Type
Capacity
OPTIONS:
- Gas type: “C” - Cl2, “S” - SO2, “N” - NH3
- No. of probes: 1 = with one pressure probe
2 = with two pressure probes
- Capacity : is chosen from technical data table below and the
suitable le er is wri en into the ordering code
Connec ons: Flange connec ons: Other connec ons on request!
1A = DN10
1B = DN25
2A = DN10
2B = DN25
DIMENSIONAL DRAWINGS
BUL00018
30 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
C
series M 3319 C
GENERAL CONSTRUCTION
The chlorine gas filters series M 3319 are designed to Main part of the filter consist of the rugged steel pres-‐
purify chlorine gas in order to avoid damages on the sure vessel (tested and cer fied) with standard DIN
feed unit, par cularly the sensi ve parts like valve connec on flanges. The main piece inside the vessel is
seats and rate valves. Addi onally, the filter together a special glass wool wrapped with a monel net.
with the heater wrapped around it, also evaporates Op onally, a self regulated heater can be wrapped
liquid rests. around the filter.
BUL00019
31
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Chlorine gas filters M 3319 C
OPTIONS:
- Gas type: “C” - Cl2, other gas by order
- Capacity*: is chosen from technical data table below and the
suitable number is wri en into the ordering code
- Heater: yes “H”, without it the le er is not wri en in
MEASURE DRAWINGS
BUL00019
32 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
E
series M 3100 C
GENERAL
Evaporators series M 3100 C are designed to heat liquid
chlorine taken from storage containers and turn it to gas
chlorine.
They are specially suitable for installa ons where
large quan es of gas are required directly from gas
drums. Evapora on is achieved mainly by electric hea ng.
The unit consists of regula on, control and safety devices
as well as the separate control panel. All parts except the
control panel are built-in the fibre glass reinforced polyes-‐
ter cabinet.
OPERATION PRINCIPLE
The spiral tube is immersed into an hot water bath of 70°
C. The thermostat-regulated hea ng creates a constant
temperature. In case of temperature drop (below 60°C) or
temperature rise (above 80°C), the alarm is ac vated. The
liquid gas under pressure enters the evaporator on the
top part, where it evaporates in the progressive hea ng LEGEND:
zone and then leaves it as a dry saturated gas, also on the 1. Scale
top part. In order to protect the installa ons (up to the 2. Ton Container
pressure reducing valve) from re-liquefac on of the gas, 3. Burs ng membrane with expansion chamber
the evaporator is designed generously, considering the 4. Evaporator
gas outlet temperature. In liquid side of the system, the 5. Pressure gauge
burs ng disk with connected expansion chamber ensures 6. Exhaust pressure safety valve
that the highest admissible opera ng pressure is not ex-‐ 7. Chlorine gas filter
ceeded. This chamber is dimensioned in a way that trans-‐ 8. Pressure reducing valve
forms the overpressure a er the burs ng of the burs ng 9. Chlorine gas Leak detector
disc into the normal opera ng pressure. On the gas side a
pressure relief valve must be installed a er a burs ng disc
and outlet must be connected to the neutraliza on de-‐
vice. A contact manometer indicates too high or to low
gas pressure. Water level in a thermal bath is strictly
monitored and water must be refilled if the level drops
under the prescribed level. All exposed parts are made of
materials or material combina ons which are absolutely
resistant to the media that needs to be evaporated, and
which are proven to resist many years of use.
BUL00020
33
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Evaporators M 3100 C
ORDER CODES
M 3100 C / X
Model
Gas type
Capacity
OPTIONS:
- Gas type: “C” - Cl2
- Capacity*: is chosen from technical data table below and the
suitable number is wri en into the ordering code
Connec ons
MEASURE DRAWINGS
BUL00020
34 Data is subject to change without no ce.
DOSING EQUIPMENT FOR AGGRESSIVE GASES
SINGLE UNITS
G
series M 3480 C
GENERAL
The M 3480 C gas chlorine pressure reducing valve is used
to sink down the unregulated gas pressure to a steady
opera ng gas pressure. The pressure reducing valve se-‐
cures pressure independent opera on of Vacuum regula-‐
tor and prevents, in rela on to pressure and temperature
changes, liquefac on of chlorine gas.
OPERATION PRINCIPLE
Through the adjustable screw the valve cone can be li ed
above the valve seat within defined limits, so that the
opera ng pressure can be set to any value between 2 and
3 bar for Cl2. Pressure fluctua ons are compensated by
the spring-loaded double diaphragm system, so that the
opera ng pressure is kept constant (at constant flow).
If the opera ng pressure exceeds the set value, the
spring-cone diaphragm system
enables the valve to close.
INSTALLATION
The gas chlorine pressure reducing valve is always mount-‐
ed in a chlorine system, so the installa on depends very
much on the system. When taken from the packing box,
the valve must be mounted as soon as possible, in other
case it must be stored in a dry place. No moisture should
enter the valve! A valve has two flanges and is mounted
in the chlorine gas system pressure line with counter
flanges and ghtens up with screws. The valve must be
mounted to the wall or to a construc on with the
a ached L-piece. If the pressure gauge is mounted onto
the valve, than it must be mounted before the valve is
mounted. To do that, remove the plug screw. Prepare the
pressure gauge and put some special chlorine gas re-‐
sistant glue on the screw. Screw the pressure gauge in
and remove the surplus glue with the rag. Watch how the
scale is turned. Now the correct pressure can be set.
BUL00021
35
DOSING EQUIPMENT FOR AGGRESSIVE GASES / SINGLE UNITS/ Gas chlorine reducing valve M 3480 C
ORDER CODES
M 3480 C / X
Model
Gas type
Capacity
OPTIONS:
- Gas type: “C” - Cl2
- Capacity*: is chosen from technical data table below and the
suitable number is wri en into the ordering code
Weight: 12,5kg
Materials:
Diaphragm: silver
Valve seat: PVDF for Cl2
Spring: Hastelloy C, silver-plated
O-Rings: Viton for Cl2
Enclosure: Brass for Cl2
MEASURE DRAWINGS
BUL00021
36 Data is subject to change without no ce.