You are on page 1of 11

Wednesday, January 12, 2022, 05:46 PM

PAGE NO. 1

****************************************************
* *
* STAAD.Pro V8i SELECTseries4 *
* Version 20.07.09.31 *
* Proprietary Program of *
* Bentley Systems, Inc. *
* Date= JAN 6, 2022 *
* Time= 2:18:41 *
* *
* USER ID: CONSTRUMATRIX-2021 *
****************************************************

1. STAAD SPACE
INPUT FILE: MURO DE BLOQUES-ING CHU.STD
2. START JOB INFORMATION
3. ENGINEER DATE 06-JAN-22
4. END JOB INFORMATION
5. INPUT WIDTH 79
6. UNIT METER KG
7. JOINT COORDINATES
8. 1 0 0 0; 2 0 3.00001 0; 3 4.20001 3.00001 0; 4 4.20001 0 0
9. 5 8.40002 3.00001 0; 6 8.40002 0 0; 7 12.6 3.00001 0; 8 12.6 0 0
10. 9 16.8 3.00001 0; 10 16.8 0 0; 11 1.05 3.00001 0; 12 1.05 2 0; 13 0 2 0
11. 14 2.1 3.00001 0; 15 2.1 2 0; 16 3.15001 3.00001 0; 17 3.15001 2 0
12. 18 4.20001 2 0; 19 1.05 1 0; 20 0 1 0; 21 2.1 1 0; 22 3.15001 1 0
13. 23 4.20001 1 0; 24 1.05 0 0; 25 2.1 0 0; 26 3.15001 0 0; 27 5.25001 3.00001 0
14. 28 5.25001 2 0; 29 6.30001 3.00001 0; 30 6.30001 2 0; 31 7.35001 3.00001 0
15. 32 7.35001 2 0; 33 8.40002 2 0; 34 5.25001 1 0; 35 6.30001 1 0; 36 7.35001 1 0
16. 37 8.40002 1 0; 38 5.25001 0 0; 39 6.30001 0 0; 40 7.35001 0 0
17. 41 9.45002 3.00001 0; 42 9.45002 2 0; 43 10.5 3.00001 0; 44 10.5 2 0
18. 45 11.55 3.00001 0; 46 11.55 2 0; 47 12.6 2 0; 48 9.45002 1 0; 49 10.5 1 0
19. 50 11.55 1 0; 51 12.6 1 0; 52 9.45002 0 0; 53 10.5 0 0; 54 11.55 0 0
20. 55 13.65 3.00001 0; 56 13.65 2 0; 57 14.7 3.00001 0; 58 14.7 2 0
21. 59 15.75 3.00001 0; 60 15.75 2 0; 61 16.8 2 0; 62 13.65 1 0; 63 14.7 1 0
22. 64 15.75 1 0; 65 16.8 1 0; 66 13.65 0 0; 67 14.7 0 0; 68 15.75 0 0
23. MEMBER INCIDENCES
24. 1 1 20; 2 2 11; 3 4 23; 4 3 27; 5 6 37; 6 5 41; 7 8 51; 8 7 55; 9 10 65
25. 10 11 14; 11 13 2; 13 14 16; 15 16 3; 17 18 3; 19 20 13; 23 23 18; 29 27 29
26. 30 29 31; 31 31 5; 32 33 5; 33 37 33; 46 41 43; 47 43 45; 48 45 7; 49 47 7
27. 50 51 47; 63 55 57; 64 57 59; 65 59 9; 66 61 9; 67 65 61
28. ELEMENT INCIDENCES SHELL
29. 12 2 11 12 13; 14 11 14 15 12; 16 14 16 17 15; 18 16 3 18 17; 20 13 12 19 20
30. 21 12 15 21 19; 22 15 17 22 21; 24 17 18 23 22; 25 20 19 24 1; 26 19 21 25 24
31. 27 21 22 26 25; 28 22 23 4 26; 34 3 27 28 18; 35 27 29 30 28; 36 29 31 32 30
32. 37 31 5 33 32; 38 18 28 34 23; 39 28 30 35 34; 40 30 32 36 35; 41 32 33 37 36
33. 42 23 34 38 4; 43 34 35 39 38; 44 35 36 40 39; 45 36 37 6 40; 51 5 41 42 33
34. 52 41 43 44 42; 53 43 45 46 44; 54 45 7 47 46; 55 33 42 48 37; 56 42 44 49 48
35. 57 44 46 50 49; 58 46 47 51 50; 59 37 48 52 6; 60 48 49 53 52; 61 49 50 54 53
36. 62 50 51 8 54; 68 7 55 56 47; 69 55 57 58 56; 70 57 59 60 58; 71 59 9 61 60
37. 72 47 56 62 51; 73 56 58 63 62; 74 58 60 64 63; 75 60 61 65 64; 76 51 62 66 8
38. 77 62 63 67 66; 78 63 64 68 67; 79 64 65 10 68

C:\Users\César V Rodríguez M\Documents\ING CHU-2022\MURO DE BLOQUES-ING CHU.anl Page 1 of 11


Wednesday, January 12, 2022, 05:46 PM
STAAD SPACE -- PAGE NO. 2

39. ELEMENT PROPERTY


40. 12 14 16 18 20 TO 22 24 TO 28 34 TO 45 51 TO 62 68 TO 79 THICKNESS 0.055
41. DEFINE MATERIAL START
42. ISOTROPIC CONCRETE
43. E 2.21466E+009
44. POISSON 0.17
45. DENSITY 2408.14
46. ALPHA 5E-006
47. DAMP 0.05
48. TYPE CONCRETE
49. STRENGTH FCU 2.81227E+006
50. END DEFINE MATERIAL
51. MEMBER PROPERTY AMERICAN
52. 1 3 5 7 9 11 17 19 23 32 33 49 50 66 67 PRIS YD 0.305 ZD 0.305
53. 2 4 6 8 10 13 15 29 TO 31 46 TO 48 63 TO 65 PRIS YD 0.305 ZD 0.2032
54. CONSTANTS
55. MATERIAL CONCRETE ALL
56. SUPPORTS
57. 1 4 6 8 10 FIXED
58. 24 TO 26 38 TO 40 52 TO 54 66 TO 68 PINNED
59. LOAD 1 LOADTYPE DEAD TITLE LOAD CASE 1 DEAD
60. SELFWEIGHT Y -1
61. LOAD 2 LOADTYPE LIVE TITLE LOAD CASE 2 LIVE
62. ELEMENT LOAD
63. 12 14 16 18 20 TO 22 24 TO 28 34 TO 45 51 TO 62 68 TO 79 PR GZ 96
64. LOAD 3 LOADTYPE WIND TITLE LOAD CASE 3 WIND
65. ELEMENT LOAD
66. 12 14 16 18 20 TO 22 24 TO 28 34 TO 45 51 TO 62 68 TO 79 PR GZ 60
67. LOAD 4 LOADTYPE SEISMIC TITLE LOAD CASE 4 SEISMIC
68. SELFWEIGHT Y -1
69. LOAD COMB 5 COMBINATION 1.4D
70. 1 1.4
71. LOAD COMB 6 COMBINATION 1.2D+1.6L
72. 1 1.2 2 1.6
73. LOAD COMB 7 COMBINATION 1.2D+L+0.8W
74. 1 1.2 2 1.0 3 0.8
75. LOAD COMB 8 COMBINATION 1.2D+1.6W+L
76. 1 1.2 3 1.6 2 1.0
77. LOAD COMB 9 COMBINATION 1.2D+0.1E+L
78. 1 1.2 4 0.1 2 1.0
79. LOAD COMB 10 COMBINATION 0.9D+1.6W
80. 1 0.9 3 1.6
81. LOAD COMB 11 COMBINATION 0.9D+0.1E
82. 1 0.9 4 0.1
83. LOAD COMB 12 COMBINATION D+L
84. 1 1.0 2 1.0
85. UNIT INCHES KIP
86. PERFORM ANALYSIS

C:\Users\César V Rodríguez M\Documents\ING CHU-2022\MURO DE BLOQUES-ING CHU.anl Page 2 of 11


Wednesday, January 12, 2022, 05:46 PM
STAAD SPACE -- PAGE NO. 3

P R O B L E M S T A T I S T I C S
-----------------------------------

NUMBER OF JOINTS 68 NUMBER OF MEMBERS 31


NUMBER OF PLATES 48 NUMBER OF SOLIDS 0
NUMBER OF SURFACES 0 NUMBER OF SUPPORTS 17

SOLVER USED IS THE IN-CORE ADVANCED SOLVER

TOTAL PRIMARY LOAD CASES = 4, TOTAL DEGREES OF FREEDOM = 342

87. START CONCRETE DESIGN

C:\Users\César V Rodríguez M\Documents\ING CHU-2022\MURO DE BLOQUES-ING CHU.anl Page 3 of 11


Wednesday, January 12, 2022, 05:46 PM
STAAD SPACE -- PAGE NO. 4

88. CODE ACI


89. CLB 1.5 MEMB 1 3 5 7 9 11 17 19 23 32 33 49 50 66 67
90. CLS 1.5 MEMB 1 3 5 7 9 11 17 19 23 32 33 49 50 66 67
91. CLT 1.5 MEMB 1 3 5 7 9 11 17 19 23 32 33 49 50 66 67
92. FC 3 MEMB 1 3 5 7 9 11 17 19 23 32 33 49 50 66 67
93. FYMAIN 60 MEMB 1 3 5 7 9 11 17 19 23 32 33 49 50 66 67
94. FYSEC 40 MEMB 1 3 5 7 9 11 17 19 23 32 33 49 50 66 67
95. MAXMAIN 5 MEMB 1 3 5 7 9 11 17 19 23 32 33 49 50 66 67
96. MINMAIN 4 MEMB 1 3 5 7 9 11 17 19 23 32 33 49 50 66 67
97. MINSEC 3 MEMB 1 3 5 7 9 11 17 19 23 32 33 49 50 66 67
98. DESIGN COLUMN 1 3 5 7 9 11 17 19 23 32 33 49 50 66 67

C:\Users\César V Rodríguez M\Documents\ING CHU-2022\MURO DE BLOQUES-ING CHU.anl Page 4 of 11


Wednesday, January 12, 2022, 05:46 PM
STAAD SPACE -- PAGE NO. 5

====================================================================

COLUMN NO. 1 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 3 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


AREA OF STEEL REQUIRED = 1.644 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

12 - NUMBER 4 1.664 8 STA 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 5 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


AREA OF STEEL REQUIRED = 1.644 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

C:\Users\César V Rodríguez M\Documents\ING CHU-2022\MURO DE BLOQUES-ING CHU.anl Page 5 of 11


Wednesday, January 12, 2022, 05:46 PM
STAAD SPACE -- PAGE NO. 6

12 - NUMBER 4 1.664 8 STA 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 7 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


AREA OF STEEL REQUIRED = 1.644 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

12 - NUMBER 4 1.664 8 STA 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 9 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 11 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

C:\Users\César V Rodríguez M\Documents\ING CHU-2022\MURO DE BLOQUES-ING CHU.anl Page 6 of 11


Wednesday, January 12, 2022, 05:46 PM
STAAD SPACE -- PAGE NO. 7

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 17 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 19 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 23 DESIGN PER ACI 318-08 - AXIAL + BENDING

C:\Users\César V Rodríguez M\Documents\ING CHU-2022\MURO DE BLOQUES-ING CHU.anl Page 7 of 11


Wednesday, January 12, 2022, 05:46 PM
STAAD SPACE -- PAGE NO. 8

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 32 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 33 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

C:\Users\César V Rodríguez M\Documents\ING CHU-2022\MURO DE BLOQUES-ING CHU.anl Page 8 of 11


Wednesday, January 12, 2022, 05:46 PM
STAAD SPACE -- PAGE NO. 9

====================================================================

COLUMN NO. 49 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 50 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 66 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

C:\Users\César V Rodríguez M\Documents\ING CHU-2022\MURO DE BLOQUES-ING CHU.anl Page 9 of 11


Wednesday, January 12, 2022, 05:46 PM
STAAD SPACE -- PAGE NO. 10

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

====================================================================

COLUMN NO. 67 DESIGN PER ACI 318-08 - AXIAL + BENDING

FY - 60000 FC - 3000 PSI, SQRE SIZE - 12.01 X 12.01 INCHES, TIED


ONLY MINIMUM STEEL IS REQUIRED.
AREA OF STEEL REQUIRED = 1.442 SQ. IN.

BAR CONFIGURATION REINF PCT. LOAD LOCATION PHI


----------------------------------------------------------

8 - NUMBER 4 1.110 1 END 0.650


(PROVIDE EQUAL NUMBER OF BARS ON EACH FACE)
TIE BAR NUMBER 3 SPACING 8.00 IN

********************END OF COLUMN DESIGN RESULTS********************

99. END CONCRETE DESIGN


100. UNIT INCHES KIP
101. FINISH

*********** END OF THE STAAD.Pro RUN ***********

**** DATE= JAN 6,2022 TIME= 2:18:44 ****

C:\Users\César V Rodríguez M\Documents\ING CHU-2022\MURO DE BLOQUES-ING CHU.anl Page 10 of 11


Wednesday, January 12, 2022, 05:46 PM
STAAD SPACE -- PAGE NO. 11

************************************************************
* For questions on STAAD.Pro, please contact *
* Bentley Systems or Partner offices *
* *
* Telephone Web / Email *
* USA +1 (714) 974-2500 *
* UK +44 (0) 808 101 9246 *
* SINGAPORE +65 6225-6158 *
* FRANCE +33 (0) 1 55238400 *
* GERMANY +49 0931 40468 *
* INDIA +91 (033) 4006-2021 *
* JAPAN +81 (03)5952-6500 http://www.ctc-g.co.jp *
* CHINA +86 21 6288 4040 *
* THAILAND +66 (0)2645-1018/19 partha.p@reisoftwareth.com*
* *
* Worldwide http://selectservices.bentley.com/en-US/ *
* *
************************************************************

C:\Users\César V Rodríguez M\Documents\ING CHU-2022\MURO DE BLOQUES-ING CHU.anl Page 11 of 11