HIGH CHIEF HYDRAULIC OPERATED

GREASE PUMP
High Chief Models 03-000920, 03-000921, 03-000950,
03-000955, 03-000955, 03-000964
Revision 3.1, Nov 2007
PART NUMBER: 03-000920, 03-000921 for 20kg pail
03-000950, 03-000951 for 60kg drum
03-000954, 03-000955 for 180kg drum
03-000964 for mini drums
SPECIFICATION: Supply Inlet Pressure: 20-200bar
Hydraulic Inlet Flow: 0.25-3.0L/m
Output Pressure: 300 bar
0 0
Operating Temp: -10 C to +60 C
Operating Voltage: 24VDC
Hydraulic Inlet Port: 7/16” JIC
Tank Return Port: 9/16” JIC
Pump Outlets: ¼” NPT
0
Max. Hyd. Fluid Temp: 98 C
3
Output per cycle: 8.8cm /cycle
3
FACTORY SETTINGS: Output: 132cm /minute

DESCRIPTION legibility of all warning and


Models 03-000920, 03-000950, 03- instruction labels.
000954, 03-000964 are hydraulically The owner/operator shall retain this
operated grease pumps using a manual for future reference to
reciprocation timer (03-000014). important warnings, operating and
Models 03-000921, 03-000951, 03- maintenance instructions.
000955 are hydraulically operated
grease pumps with no timer but WARNING
designed to be used in conjunction FAILURE TO HEED THE FOLLOWING
with the JSG “G2” dual controller WARNINGS INCLUDING MISUSE,
(13-002500) which has two control OVER PRESSURISING, MODIFYING
outputs, one output controlling the PARTS, USING INCOMPATIBLE
pump speed the second output CHEMICALS AND FLUIDS, OR USING
WORN OR DAMAGED PARTS, MAY
controlling the pump on time and the RESULT IN EQUIPMENT DAMAGE
lubrication cycle. All models are AND/OR SERIOUS PERSONAL
designed for centralised lubrication INJURY.
systems for any equipment which
utilises 24VDC power source. (With y Do not exceed the stated maximum
working pressure of the pump or of
“G2” Timer can use 12VDC)
the lowest rated component in your
system.
OWNER/OPERATOR y Do not alter or modify any part of this
RESPONSIBILITY equipment.
It is the owner/operator y Do not attempt to repair or
responsibility to properly use and disassemble the equipment while the
maintain this equipment. system is pressurised.
The instructions and warnings y Make sure all fluid connections are
contained in this manual shall be securely tightened before using this
read and understood by the equipment.
owner/operator prior to operating y Always read and follow the Fluid
equipment. manufacturer’s recommendations
If an owner/operator does not regarding fluid compatibility, and the
use of protective clothing and
understand English, a request must
equipment.
be made to have the contents of this
y Check all equipment regularly and
manual explained in the repair or replace worn or damaged
owner/operator native language to parts immediately.
assure the owner/operator
comprehends.
It is the owner / operator
responsibility to maintain the

JSG INDUSTRIAL SYSTEMS PTY LTD Page 1


HIGH CHIEF MANUAL
Revision 3.1, Nov 2007

BASIC PUMP DRUM SIZE DIMENSION A


03-000920, 03-000921 20kg 479 mm
03-000950, 03-000951 60kg 552 mm
03-000954, 03-000955 180kg 862mm
03-000964 Mini Pump 350mm

FIGURE 1. GENERAL INFORMATION

SAFETY INSTRUCTIONS Specialised equipment and


This equipment generates very high
WARNING knowledge is required for repair of
grease pressure. Extreme caution this pump.
should be used when operating this DO NOT alter or
equipment as material leaks from Contact JSG Industrial Systems or
loose or ruptured components can modify any part of your nearest authorised JSG service
inject fluid through the skin and into the equipment as centre for repairs or adjustments
the body causing serious bodily other than maintenance specified in
this may cause a this manual.
injury including possible need for
amputation. Adequate protection is
malfunction and
recommended to prevent splashing result in serious Annual inspection by JSG Industrial
of material onto the skin or into the bodily injury. Systems is recommended.
eyes.
DAMAGED PUMPS
IMPORTANT INSPECTION Any pump that appears to be
If any fluid appears to penetrate damaged in any way, is badly worn
If over pressurising of the equipment
the skin, get emergency medical or operates abnormally shall be
care immediately. Do not treat
is believed to have occurred, contact
JSG Industrial Systems or your removed from use until repairs are
as a simple cut. Tell attending
nearest service centre. made. Contact JSG Industrial
physician exactly what fluid was
injected. Systems for repairs.

JSG INDUSTRIAL SYSTEMS PTY LTD Page 2


HIGH CHIEF MANUAL
Revision 3.1, Nov 2007

Reciprocation solenoid valve

NOTE:
THE THEORETICAL RATIO OF THIS PUMP IS 15:1
DEPENDANT ON THE APPLICATION AND
VARIABLE INTERNAL FRICTION; THE ACTUAL FIGURE 2 – PUMP
RATIO MAY BE LESS. MOTOR CIRCUIT

HYDRAULIC MOTOR reciprocation rate however 2


OPERATION to the “P1” port it will show the 20 seconds on and 2 seconds off is the
This section describes the operation bar setting of the integral pressure factory recommendations.
of the hydraulic Motor Assembly. reducing valve. During operation the
(See Figure 2) pressure gauge reading will fluctuate In the Rest State hydraulic pressure
in time with the reciprocating rate of is normally applied to the top of the
WARNING the pump. Motor, holding the piston at the end
of its down stroke.
Maximum allowable output NOTE: Applying 24 volt DC Power to the
pressure of this pump is 360 If operating vent valve (01-084980) reciprocation timer (03-000014) will
bar. Be sure that all system from auxiliary port “P1”, an orifice start the reciprocating action by
equipment and accessories are (03-247384) must be fitted. When operating the solenoid valve, thus
rated to withstand the ordering the orifice please state sending the piston to the top of its
maximum working pressure of version of reciprocating assembly stroke and then back again, at the
this pump. DO NOT exceed the you have. With this setup an rate set by the timer. Turning the 24-
maximum working pressure of additional hydraulic 2/3 way shut off volt supply off will stop the
the lowest rated component in valve must be fitted in the hydraulic reciprocation timer thus interrupting
the system. supply line. the power to the solenoid and return
the piston to its rest position at the
The pump operates as follows: bottom of its stroke.
The “P” port should be connected to The reciprocation timer used in
a suitable hydraulic supply,
preferably to a pilot system.
models 03-000920, 03-000950, 03- WARNING
000954, (03-000014) determines the
The “T “ port is the return to tank number of cycles per minute. (The A pressure switch and safety
line. factory setting is 2 seconds on & 2 valve must be used in the
seconds off, which results in 15 lube system. The cylinder
The “P1” port is an auxiliary port, cycles / minute.) pressure must not exceed 20
which is normally left plugged. It is By utilising the JSG “G2” timer with bar. Failure to use these
suitable for use as a gauge port or if the High Chief Hydraulic Pump monitoring and safety
necessary to operate a hydraulic models 03-000921, 03-000951, & devices may result in damage
vent valve. If a gauge is connected 03-000955 this cycle can be to system components and
adjusted to whatever required personal injury!

JSG INDUSTRIAL SYSTEMS PTY LTD Page 3


HIGH CHIEF MANUAL
Revision 3.1, Nov 2007

FIGURE 3 – PUMP MOTOR WITH RECRIPROCATING TIMER

There are two LED lights under the


opaque cover of the reciprocation Pump pressure builds very G. Replace shovel rod if rough or
timer. (See figure 3) One indicates slowly or not at all pitted. Replace shovel rod
that power is applied the other blinks packing.
on and off as it operates the
reciprocation solenoid valve. A. No pulsing signal from H. Inspect lubricant supply line for
reciprocation timer. leaks or breaks.
TROUBLE SHOOTING
B. Pressure reducing valve may be I. If hydraulic vent valve is used
set to low. then an orifice (03-247384)
If the following procedures do not
must be fitted in “P1” auxiliary
correct the problem, contact JSG C. Grease viscosity may be too port. Problem can be caused
Industrial Systems Pty Ltd or a JSG high for temperature at which either by missing orifice or
authorised service centre. When pump is operating. clogged orifice (see note page
submitting equipment to be repaired,
3.)
be sure to state the nature of the D. If pressure is not building at all,
problem and indicate if a repair cost the reciprocation solenoid may
estimate is required. be inoperative.
E. Pump piston ball checks and
PROBLEMS inlet checks may have foreign
No or low hydraulic pressure at matter trapped causing leakage.
the Auxiliary port. Remove, inspect and clean if
A. No system pressure to the necessary.
pump.
F. Inspect sealing surfaces
B. Pressure reducing valve set to between upper and lower inlet
low. Increase setting by ½ turn checks. Replace if rough or
to check operation. pitted.

JSG INDUSTRIAL SYSTEMS PTY LTD Page 4


HIGH CHIEF MANUAL
Revision 3.1, Nov 2007

DISASSEMBLY 011724) to allow removal of JSG OFFICE LOCATIONS


priming check parts and plunger
Refer to SERVICE PARTS for part rod (01-011723). Head Office
numbers and location. Bleed all 8 Sheridan Close,
pressure from hydraulic and grease L. Remove bushing extension (01- Milperra NSW 2214
lines before disassembling pumps. 061273) and unscrew plunger Phone: (02) 9914 8720
bushing assembly (01-090554) Fax: (02) 9774 2321
A. Remove nut securing solenoid from pump tube. Unscrew Email: jsgindustrial@jsg.com.au
coil. Remove the coil together coupling nut (01-011344) to Web: www.jsgindustrial.com
with the reciprocation timer. allow removal of plunger and
bushing assembly intact, Brisbane Office
B. Remove socket head cap reducing the chance of loosing 20 Lancashire Street
screws securing reciprocation ball stop (01-057027) and check Acacia Ridge Qld 4110
valve assembly and remove ball (01-066010). Phone: (07) 3273 3433
assembly. Fax: (07) 3273 3369
ASSEMBLY Email: jsgqld@ozemail.com.au
C. Remove socket head screws To reassemble, perform
securing hydraulic cylinder top DISASSEMBLY procedure in Townsville Office
(03-000013-1) and remove top. reverse. Level 1, 1/5 Woolcock Street
Hyde Park Townsville Qld 4810
D. Remove hydraulic cylinder. IMPORTANT Phone: (07) 4772 5454
To prevent damage to pump gland Fax: (07) 4724 5951
E. Remove cylinder tie rods by packing and to help increase Email: jsgfnq@bigpond.net
unscrewing them from outlet packing life, lube pump piston rod
body. before assembly. Thread piston North Mackay Office
rod through gland packing when 2/40 Evans Avenue, PO Box 3374
F. The cylinder bottom will now be assembling pump. North Mackay Qld 4740
partially free of the outlet body Mobile: 0428 277 671
(03-001311) Fax: (07) 4953 3959
Email: jsgcq@bigpond.com
G. Unscrew pump tube from outlet REPAIR
body (03-001311). Melbourne Office
Repair is limited to replacement of 4/18 Floriston Road
H. Extend pump piston rod (01- listed service parts. Special Boronia Vic 3155
011340) out of the bottom of procedures and tools are required. Phone: (03) 9762 4744
outlet body (03-0001311). Place Contact JSG Technical service for Fax: (03) 9762 4772
wrenches on piston rod end and details and your nearest authorised Email:jsgvic@alphalink.com.au
flats of piston boss (03-000013- service centre.
6) and flats of piston rod (01- When ordering replacement parts, Perth Office
011340) and unscrew piston list the part number, description, Unit 4/11 Townsend Street
rod. Thread the piston rod model number and series letter of Malaga WA 6090
through the gland packing to the product to be repaired. Phone: (08) 9248 7311
allow removal of the pump tube. Fax: (08) 9248 9817
Email: jsgwa@space.net.au
I. Unscrew gland packing nut (01-
ACCESSORIES
012333) from outlet body and AUTHORISED SERVICE
remove all gland parts. 01-245530 Viton / Teflon kit
CENTRES THROUGHOUT:
(For Pumping
J. Remove the priming tube (01- Synthetic
New South Wales, Queensland,
239719) from the bushing Lubricants)
Victoria, South Australia, Western
extension (01-061273). 01-083001 Lower Pump
Australia, Tasmania, Northern
Tube repair Kit
Territory, Indonesia, Papua New
K. Extend plunger rod (01-011723) 03-000920-9V Hydraulic
Guinea, New Caledonia, Fiji, New
out of bushing extension and cylinder seal kit.
Zealand
unscrew priming extension (01-

JSG INDUSTRIAL SYSTEMS PTY LTD Page 5


HIGH CHIEF MANUAL
Revision 3.1, Nov 07

Gland Assembly Note: 2 x thin washers P/No 01-048213 and 1 x


copper gasket P/No 01-031050 must be assembled as shown in the
diagram. After the nut P/No 01-012333 has been tightened check for 01-012333
proper compression of the copper gasket by trying to move the top thin
washer P/No 01-048213 with a screw driver. It should be possible to just
move the washer. If the thin washer cannot be moved check to see if the
01-048213
copper gasket P/No 01-031050 is in place or the correct thin washer
P/No 01-048213 has been used. 03-38165V

01-031050
01-034572

03-016576
01-034572

03-38165V

03-0185-5707
01-048213

01-011349
USE LOCKTITE 510
GASKET ELIMINATOR
ON THREADS
01-031048

IMPORTANT
START FASTENERS BY HAND
PUMP TO AVOID STRIPPING
TUBE
01-057027
01-066010

PISTON
ROD

01-061407

A 01-011346

01-011345

01-090554
01-057027
01-011344 01-066010

01-31047

01-011726

01-011723

01-011722

01-031049 01-035073

01-011340 01-011702

01-012333
01-011721

01-011725

01-061273 01-011724

01-061275

BASIC PUMP PISTON ROD PUMP TUBE DRUM SIZE DIMENSION A


03-000920, 03-000921 01-011799 01-061293 20 kg 479 mm
03-000950, 03-000951 03-013020 03-061407 60 kg 552 mm
03-000954, 03-000955 01-011761 01-246118 180kg 862 mm
03-000964 01-011064 01-061064 Mini Pump 350 mm
Note: 1. The Seal Kit Part No. 03-000920-9V is a combination of 7 seals for hydraulic cylinder.
2. Lower Pump Tube Kit Part No. 01-083001.
3. Gland Seals 1 x 01-031050, 2 x 03-038165V, 2 x 01-034572 not in kit. Order separately.

JSG INDUSTRIAL SYSTEMS PTY LTD Page 6


HIGH CHIEF MANUAL
Revision 3.1, Nov 2007

TORQUE SPECIFICATIONS
1 14 Nm 4 108 Nm

2 41 Nm 5 122 Nm

3 61 Nm 6 136 Nm

JSG INDUSTRIAL SYSTEMS PTY LTD Page 7


HIGH CHIEF MANUAL
Revision 3.1, Nov 2007

PARTS LIST

PART NO. QTY DESCRIPTION PART NO. QTY DESCRIPTION


03-000013-1 1 Cylinder Top 01-011721 * 1 Priming check
03-000013-2 1 Cylinder 01-011722 1 Check stop
03-000013-3 1 Cylinder Base 01-011723 * 1 Plunger rod
03-000013-5 1 Valve Reciprocating Assy 01-011724 * 1 Priming plunger
03-000013-5-CS 1 Complete cartridge 2/4 way & 01-011725 * 1 Priming check seat
24VDC Solenoid
03-000013-5-PRC 1 Pressure Reducing Valve 01-011726 * 1 Check seat
03-000013-6 1 Piston (long boss) 01-031047 * 1 Check seat gasket
03-000013-7-2 4 Cylinder tie rods 01-031048 1 Connector gasket
03-000014 1 Reciprocation timer 01-031049 2 Bushing gasket
03-001311 1 Outlet steel body 01-031050 1 Gland gasket
03-016576 1 Gland packing spacer 01-031054 1 Pump tube gasket
03-0185-5704 6+ Set screws ¼” x 3/4” 01-034572 2 O-ring
03-0185-6606 2 Set screws ¼” x 2 3/4” 01-035073 * 1 Priming check pack’g
03-000920-9V 1 Seal kit (cylinder) 03-38165V 2 U-packing
01-011340 1 Piston rod 01-048213 2 Gland packing washer
01-011344 1 Plunger adaptor 01-057027 2 Ball stop
01-011345 1 Coupling nut 01-061273 1 Bushing extension
01-011346 1 Coupling nut 01-066010 * 4 Ball
01-011349 1 Piston rod connector 01-090544 1 Plunger & bushing assy
01-011702 * 1 Check washer 01-239719 1 Priming tube
• * Included in 01-083001 Lower Pump Tube Repair Kit.
• + 4 off required for Tie Rods, 2 off required for bottom section of valve

UPGRADE KIT 03-000940


from PILOT CHIEF to HIGH CHIEF
Hydraulic Motor End Only
PART NO. QTY DESCRIPTION
01-031050 1 Gland Gasket
01-031054 1 Copper Gasket
01-034572 2 O-Ring
01-048213 2 Packing Washer
01-083001 1 Repair Kit
03-001311 1 Outlet Steel Body
03-016576 1 Gland Spacer
03-038165V 2 U-Packing
03-000013-9V1 2 Viton O-Ring
03-000013-9V2 4 Viton O-Ring
03-000013-9V4 1 Viton O-Ring
03-000013-7-2 4 Tie Rods 3/8” UNC
NOTE: Kit does not include Cylinder or piston

JSG INDUSTRIAL SYSTEMS PTY LTD Page 8


HIGH CHIEF MANUAL
Revision 3.1, Nov 2007

Figure AA

Detailed wiring diagram


for the connection of
the JSG “G2” Timer to
the High Chief Pump.

JSG INDUSTRIAL SYSTEMS PTY LTD Page 9


HIGH CHIEF MANUAL
Revision 3.1, Nov 2007

PRODUCT DETAILS USING JSG “G2” TIMER

HIGH CHIEF PUMP HIGH CHIEF PUMP – COMPLETE TIMER “G2” TIMER 5 METRE
– NO TIMER WITH “G2” TIMER WITH 5M CABLE ONLY CABLE ONLY
03-000921 03-000921-T 13-002500 13-002500-1 13-002500-2
03-000951 03-000951-T 13-002500 13-002500-1 13-002500-2
03-000955 03-000955-T 13-002500 13-002500-1 13-002500-2
Note: Models 03-000920, 03-000950, 03-000954 come fitted with a reciprocating timer 03-000014

For more technical detail on the JSG “G2” timer please refer to the “G2” manual.

Product Warranty

JSG Industrial Systems Pty Ltd (hereinafter called “JSG”) warrants that all products marketed by
JSG will be free from defects in material and workmanship during one (1) year period following
the date of purchase. If the equipment is deemed to be defective during this warranty
period, it will be repaired or replaced without charge, providing examination proved the
equipment to be defective. To obtain repair or replacement if must be shipped
”transportation charges prepaid”, with proof of date of purchase, to either JSG or one of its
authorised Service Centres within one (1) year following the date of purchase.

This warrant is extended to the original retail purchaser only. This warranty does not apply to
equipment damaged by accident, overload, abuse, misuse, negligence, faulty installation or
abrasive or corrosive materials, or to equipment repaired or altered by anyone not authorised
by JSG to repair to alter the equipment. This warranty applies only to equipment specified,
approved installed and operated according to the recommendations of JSG. No other
express warranty applies to lubrication equipment, material dispensing equipment, hose and
cable management equipment, or other related equipment supplied by JSG.

In no event shall JSG be liable for incidental or consequential damages. The liability of JSG on
any claim for loss or damage arising out of the sale, resale, or use of lubrication equipment,
material dispensing equipment, hose and cable management equipment, or other related
equipment shall in no event exceed the purchase price.

JSG INDUSTRIAL SYSTEMS PTY LTD Page 10