Professional Documents
Culture Documents
One-touch Fittings
With G Type Connection Threads
Series KQ2
Seal Chuck
Can be used for a wide range Large retaining force
of pressures from a low Has large retaining force while holding
vacuum up to a pressure force is increased by the collet.
of 1.0 MPa
The use of a special profile Collet
ensures sealing and reduces
resistance when the tube is
Guide
inserted.
Body
O-ring
Stud
Effective when piping in
a confined space. Tube
The body and the threaded
portion can rotate (To the
degree for positioning)
Release button (Light grey)
Light force for removal
Gasket When the fitting is removed from the
tube, the check and collet are
released, thus preventing them from
G thread biting into the tube excessively.
One-touch Fittings
Series KQ2
Applicable Tubing: Metric Size
Connection Thread: G
The seal gasket on the male thread for piping eliminates the need for pipe tape
Seal Chuck
Can be used for a wide range Large retaining force
Gasket of pressures from a low Has large retaining force while holding
vacuum up to a pressure of force is increased by the collet.
1.0 MPa
Female thread The use of a special profile Collet
ensures sealing and reduces
Male thread
G
resistance when the tube is Guide
inserted.
Body
• G thread O-ring
A gasket made of a stainless sheet
covered with laminated NBR on both
sides is seated on the female thread Stud
for a perfect sealing construction Effective when piping in
irrespective of the variations in a confined space. Tube
tolerance. The body and the threaded
portion can rotate (To the
Release button (Light grey)
• One-touch connection and degree for positioning)
Light force for removal
release. Gasket When the fitting is removed from the
• Possible to use in vacuum tube, the check and collet are
released, thus preventing them from
to -100 kPa. G thread biting into the tube excessively.
• The male thread for piping
drastically cuts piping man- Applicable Tubing
hours. Tubing material FEP,PFA, Nylon, Soft nylon (Note1), Polyurethane
• Suitable for use with port Tubing O.D. ø4, ø6, ø8, ø10, ø12, ø16
threads conforming to Note 1) The soft nylon tube is not available with water.
ISO1179 and ISO16030.
Product’s Color
Series Body Release button
Series KQ2 White Light grey
Specifications
Fluid Air/Water Note 2)
Operating pressure range 1.0 MPa Note 3)
Proof pressure 3.0 MPa
Ambient and fluid temperature –5 to 60°C, Water: 0 to 40°C (No freezing)
Thread Mounting Section JIS B0207 (EN ISO228)
Nut Section JIS B0211 Class 2 (Metric fine thread)
Note 2) The surge pressure must be under the maximum operating pressure.
Note 3) The amount of leakage is not zero, and so the use for holding vacuum such as a leak
tester should be avoided.
2
One-touch Fittings Series KQ2
Model
Male connector
Use to pipe in the
KQ2H
same direction from
female thread. Most Male branch tee
general style. KQ2T Use to branch line
from female thread in
both 90° directions.
Female Connector
KQ2F Use to pipe from
male thread such
as pressure gauge. Male run tee
KQ2Y Use to branch line in
the same direction
from female thread
and in 90° direction.
Male elbow
KQ2L Use to pipe at right
angles to female
thread. Most general
style.
How to Order
KQ 2 H 06 G01
One-touch Applicable tubing O.D.
fittings 04 ø4
06 ø6 Port size
Product's color 08 ø8 G01 G1 8
connection
Thread
Model
H Male connector T Male branch tee
S Hex. socket head male connector Y Male run tee
L Male elbow F Female connector
E Bulkhead connector
V Universal male elbow
W Extended male elbow
3
Series KQ2
Male Connector: KQ2H
Applicable Connection H (1) (2)
(3)
tubing O.D. thread Model (width across ØD1 ØD2 L A M
(mm) G flats)
18 KQ2H04-G01 13 _ 14 21.5 16.9
4 _ 16
14 KQ2H04-G02 16 17 17.7 11.6
18 KQ2H06-G01 13 _ 14 24 19.4 øD1 Applicable
6 14 KQ2H06-G02 16 _ 17 23 16.9 17 tubing
38 KQ2H06-G03 20 _ 21 19.7 13.6
18 KQ2H08-G01 14 _ 14 27.9 23.3
_
A
8 14 KQ2H08-G02 16 17 23.9 17.8 18.5
M
L
38 KQ2H08-G03 20 _ 21 23.9 17.8 H
18 KQ2H10-G01 17 _ 14 30 25.4
14 KQ2H10-G02 17 _ 17 31 24.9
10 _ 21 Connection
38 KQ2H10-G03 20 21 25.5 19.4
_ øD2 thread
12 KQ2H10-G04 24 25 27.5 18.9
14 KQ2H12-G02 19 _ 17 32 25.9
12 38 KQ2H12-G03 20 _ 21 32 25.9 22
12 KQ2H12-G04 24 _ 25 28 19.4
38 KQ2H16-G03 24 25.7 21 35.5 29.4
16 25
12 KQ2H16-G04 24 25.7 25 37.5 28.9
Note1) øD1: Max. diameter
Note2) øD2: Gasket O.D.
Note3) Reference dimensions after G thread installation.
øD1
18.5
38 KQ2L08-G03 20 21 28.2 29.7
A
4
One-touch Fittings Series KQ2
Male Run Tee: KQ2Y
Applicable Connection H (1) (2)
tubing O.D. thread (width øD1 øD2 øD3 L1 L2 A
(3)
M
Model across
G
(mm) flats) 2-Applicable L1
18 KQ2Y04-G01 13 14 21.2 34.6 tubing
4 10.4 10 18 16
14 KQ2Y04-G02 16 17 24.2 36.1
18 KQ2Y06-G01 13 14 22.2 37.6
6 14 KQ2Y06-G02 16 12.8 10 17 20 25.2 39.1 17 øD1
M
38 KQ2Y06-G03 20 21 27.2 41.1
L1
18 KQ2Y08-G01 13 14 23.7 42.1
8 14 KQ2Y08-G02 16 15.2 12 17 23 26.7 43.6 18.5
A
38 KQ2Y08-G03 20 21 28.2 45.1
øD1
18 KQ2Y10-G01 14 25.1 46.9
14
17
KQ2Y10-G02 17 28.2 48.6
10 18.5 17 26.5 21 M
38 KQ2Y10-G03 20 21 29.7 50.1 øD2
L2
12 KQ2Y10-G04 24 25 34.5 52.4
14 KQ2Y12-G02 17 17 29.3 51.7
H
12 38 KQ2Y12-G03 20 20.9 17 21 28.5 30.8 53.2 22
12 KQ2Y12-G04 24 25 35.6 55.5 Connection
38 KQ2Y16-G03 22 21 35.9 65.9 øD3 thread
16 12
26.5 20.9 36.1 25
KQ2Y16-G04 24 25 38.4 65.9
Note1) øD1: Max. diameter
Note2) øD3: Gasket O.D.
Note3) Reference dimensions after G thread installation.
øD1
38 KQ2F06-G03 21 35.2 15.7 11.4 tubing
18 KQ2F08-G01 14 29.7 10.9 7.4
8 14 KQ2F08-G02 17 _ 14 35.1 15.3 11 18.5
øD2
38 KQ2F08-G03 21 36.6 15.5 11.4
14 KQ2F10-G02 17 _ 15.3 11
10 17 36.7 21
38 KQ2F10-G03 21 38.3 15.5 11.4
14 KQ2F12-G02 19 37.3 15.8 11 L3
38 _ 19 38.8
12 KQ2F12-G03 21 16.6 11.4 22 L2 M
12 KQ2F12-G04 24 43.9 20.8 15 L1
38 KQ2F16-G03 16 11.4
16 24 24 25.7 39.4 25
12 KQ2F16-G04 46.3 22.9 15
Note1) øD2: Max. diameter
5
Series KQ2
Hexagon Socket Head Male Connector: KQ2S
Applicable Connection H (1) (2)
thread (width (3)
tubing O.D.
G
Model across øD1 øD2 L A M
øD1
(mm) flats) Applicable tubing
4 18 KQ2S04-G01 3 13 14 23 18.4 16
18 KQ2S06-G01 13 14 24 19.4
6 4 17
14 KQ2S06-G02 16 17 24 17.9
18 KQ2S08-G01 5 14 14 26.6 22
M
8 14 KQ2S08-G02 16 17 28.5 22.4 18.5
A
38 6
KQ2S08-G03 20 21 29.1 23
L
18 KQ2S10-G01 5 17 14 29.3 24.7
14 KQ2S10-G02 17 17 29.7 23.6
10 21
38 KQ2S10-G03 8 20 21 27.9 21.8
12 KQ2S10-G04 24 25 28.4 19.8
14 KQ2S12-G02 8 19 17 32 25.9 Connection thread
12 38 KQ2S12-G03 20 21 32 25.9 22 øD2
12
10
KQ2S12-G04 24 25 28 19.4
38 KQ2S16-G03 10 25.7 21 35.5 29.4
25
12 KQ2S16-G04 12 25.7 25 37.5 28.9
Note1) øD1: Max. diameter
Note2) øD2: Gasket O.D.
Note3) Reference dimensions after G thread installation.
øD1
6
One-touch Fittings Series KQ2
Precautions
Be sure to read before handling.
Refer to SMC´s "Best Pneumatics" catalogue for Safety Instructions and Common Precautions on the products
mentioned in this catalog.
7
EUROPEAN SUBSIDIARIES:
© DiskArt™ 1988
UK
SMC Industrial Automation CZ s.r.o. SMC Pneumatics (Ireland) Ltd. SMC Romania srl SMC Pneumatics (UK) Ltd
Hudcova 78a, CZ-61200 Brno 2002 Citywest Business Campus, Naas Road, Saggart, Co. Dublin Str Frunzei 29, Sector 2, Bucharest Vincent Avenue, Crownhill, Milton Keynes, MK8 0AN
Phone: +420 5 414 24611, Fax: +420 5 412 18034 Phone: +353 (0)1-403 9000, Fax: +353 (0)1-464-0500 Phone: +40 213205111, Fax: +40 213261489 Phone: +44 (0)800 1382930 Fax: +44 (0)1908-555064
E-mail: office@smc.cz E-mail: sales@smcpneumatics.ie E-mail: smcromania@smcromania.ro E-mail: sales@smcpneumatics.co.uk
http://www.smc.cz http://www.smcpneumatics.ie http://www.smcromania.ro http://www.smcpneumatics.co.uk
http://www.smc.eu
http://www.smcworld.com
SMC CORPORATION Akihabara UDX 15F, 4-14-1, Sotokanda, Chiyoda-ku, Tokyo 101-0021, JAPAN Phone: 03-5207-8249 FAX: 03-5298-5362
1st printing MO printing MO 00 Printed in Spain Specifications are subject to change without prior notice
and any obligation on the part of the manufacturer.