o Main floor Footings, basement floor, foundation o Basement wall, furred out wall Concrete reinforcement Stair Section (1/2” = 1’-0”) Mudsill, floor joist, rim joist Floors, walls, beams, supports Grade (min 8” below top of foundation) Stairs (stringers, treads, risers) Exterior finishes, sheathing, gyp board, Landings insulation Fireproofing (Type “X” gyp board) Wall stud, sole plate, double top plate Handrails/guardrails Truss, sheathing, fascia, soffit, gutter, Connections (double rim, kickblock) shingles Local notes Materials depicted and called out o Tread/riser size o See example wall section o Stringer size Elevations o Kickblock size o Top plate o Header, blocking, etc. o Top of subfloor o Type “X” gyp board o Top of Footing o Handrail/guardrail Dimensions Elevations o Top of footing to foundation o Main floor o Foundation to top of subfloor o Basement o Top of subfloor to top plate Dimensions Local notes o Total rise and run o See example wall section o Tread depth (minimum per code) Lateral Section (1/4” = 1’-0”) o Riser height (max per code) o Head clearance Footings, basement floor, foundation o Handrail/guardrail height (range per wall, furred out walls code) Mudsill, floor joist, rim joist o Handrail/guardrail baluster spacing Wall studs, sole plates, double top plates Overall Truss, sheathing, fascia, soffit, gutter Sheet Notes – see below Insulation View Titles/Scale Local notes Title Block o Roof truss o Sheet title – Sections o Room names o Sheet – A301 Elevations
• MAX RISER HEIGHT = 7 3/4" • MIN HEAD CLEARANCE = 6'-8" • MAX RISER/TREAD VARIANCE = 3/8" • HANDRAIL HEIGHT IS 34" TO 38" • USE 5/8" TYPE "X" GYP BOARD AT ALL ENCLOSED AREAS UNDER STAIRS. • HANDRAILS MAY ENCROACH UPON STAIR WIDTH A MAX OF 4 1/2". • HANDRAILS REQUIRED ALONG STAIRS W/ (2) OR MORE TREADS. • PROVIDE GAURDRAILS AT LANDINGS, BALCONIES, AND/OR DECKS LOCATED MORE THAN 30" VERTICALLY TO FLOOR/GRADE BELOW. • BALLUSTERS SHALL BE PLACED SO A 4" SPHERE CANNOT PASS THROUGH.