You are on page 1of 52

CATALOG 

Power Meter & Energy Meter


Motor Protection Controller
Multi-Channel Power Meter
Smart Gateway
Current Transformer

ZHUHAI PILOT TECHNOLOGY CO., LTD.


25

Our main products:


Power Meters and Energy Meters
Power Quality Analyzers
Motor Protection Devices
Smart Gateways
AC and DC EV Chargers
Battery Monitoring System
New product
EGO700 IoT 4G/Lora Wireless Power Meter

0 Single Phase DC Energy Meter 10


11
12

14
16
18
80H Quality Analyzer 22

Motor Protection Controller


PMAC801A Motor Protection Controller 26

SPM20 AC Multi-Channel Energy Meter 30 29


SPM20-D DC Multi-Channel Energy Meter 32
PMAC211 AC Multi-Channel Energy Meter 34

System Solution
xGate6-Lite Smart Gateway 37
39

Current Transformer

CTSB Split Core Current Transformers 44


BH - 0.66 SeriesⅠSolid Core Current Transformers 46
ISO45001

CMMI2.0 ML3 SPM33 CE


EGO700 SPM90 (DC) SPM91 SPM93 SPM32 SPM33 PMAC770 PMAC780H SPM20 PMAC211

3 30 Channel 12 Channel

(NO “F”)

IEC61850 Protocol
Charter 1

Power Meter
Energy Meter
Motor Protection Controller
EGO700 IoT Multifunction Power Meter

Combine Measuring and Electricity Monitoring Into One


Full Parameter Measuring and Power Quality Monitoring
Measure and alarm for residual current and cable temperature

Reliable Data Transfer

7 days Data Cache & Retransmit


10 sec. keep working to posting POWER-OFF alarm
1 sec. real-time data upload

Multiple Communication Protocol

4G / LoRa / RS485

Remote Support and Engineering Simplification


EGO700
P2P remote configuration & free maintenance
Phase-sequence auto adjustment
Split core CT for easy installtion

System Structure

4G
LoRa
RS485

Multiple Platform Monitoring

Internet
P2P Remote
4G Operator Maintenance

6
EGO700 IoT Multifunction Power Meter

Measurement Power Quality Analysis

Voltage, current, active power, reactive power, Three phase voltage/current, 63rd harmonic analysis,
apparent power, power factor, frequency, active voltage/current unbalance
energy, reactive energy , apparent energy, voltage
and current phase angle, cable temperature,
residual current, switch detection Demand Calculation

Latest 10 years, 12 months, 31 days historical Maximum and real-time demand of power and current
energy Real-time demand, daily and monthly max. demand

Setpoint Alarm
Communication
Support alarming of over-voltage, under-voltage, over-current,
Standard 1 RS485 and 1 infrared communication
under-current, lost phase, power over limit, over temperature, leakage
4G / LoRa optional, support Modbus, Http, Mqtt
current and power failure with SOE time record.
communication etc, support Modbus-RTU and
Modbus-TCP, register is definable
Support break-point transfer

AC 85~265V / LoRa 470-510Mhz, 1KM open area


Power Supply
DC 100~300V
RS485 4800-38400bps
Rated Current 1.67mA,
5A/1.67mA Break-point
(Optional) 7 days data cache (1 sampling point / 5min.)
100A/33.3mA transfer

Rated Voltage 3x57.7/100V, 3x220/380V


Operation Temperature: -25℃~+70℃
Wet contact, external power supply: Environment Storage Temperature: -40℃~+85℃
220V, when<60V, open, when> Operation Humidity: 5% ~ 95% Non-condensing
Digital Input
140V, closed, Max. Input: 300V
Or Dry contact: internal supply
24Vdc
Electrostatic Discharge Immunity Test IEC61000-4-2:2001
Connection Mode 3P4W, 3P3W RF Electromagnetic Field Immunity testing IEC61000-4-3:2002
Electrical fast transient immunity test IEC61000-4-4:2006
LTE-FDD B1/B3/B5/B8
LTE Wireless EMC Standard Surge immunity test IEC61000-4-5:2005
Communication Injected Current Immunity Test IEC61000-4-6:2006
LTE-FDD B34/B38/B39/B40/B41
Electromagnetic emission limit CISPR22:2006
Residual Current 1 x 0-8000mA Voltage sag and short-time interruption Immunity testing Passed
Cable
4 x 0-150℃
Temperature

7
EGO700 IoT Multifunction Power Meter

Parameter Measurement Range Accuracy

Phase Voltage: 10V~400V


Line Voltage: 10V~500V 0.2%

Primary Voltage Max. 1000kV -

Current 5mA~6.5A 0.2%

Primary Current Max. 100000A -

Frequency 40~70Hz 0.1%

Active Energy 0~99999999.9 kWh 0.5%

Reactive Energy 0~99999999.9 kWh 2%

Active Power Single Phase: 0 ~ ±9999MW/Mvar 0.5%


Total: 0 ~ ±9999MW/Mvar
Reactive Power 1.0%

Harmonic 0%~100% Class B

35mm Din-Rail

8
EGO700 IoT Multifunction Power Meter

CTO, CTC connection

EGO700

CTO-5 —— Comes with 5A/ 1.67mA Split core CT

Optional input CTO-100—— Comes with 100A/ 33.3mA Split core CT


current
CTC ——Comes with module 5A/ 1.67mA

RS485 —— 1 x RS485

LoRa —— LoRa, RS485


Communication
4G —— Lte(4G), RS485

All —— Lte(4G), LoRa, RS485

9
0 C Energy Meter

Basic Function
Real-time measure one circuit DC voltage, current, power , kWh
High accuracy: Class 0.5
One LED indicate pulse output
RS485 port, MODBUS-RTU or DL/T645 protocol (optional)
35mm DIN rail installing, standard DIN ED5002
Shunt: 100A, 200A, 300A, 400A

Power supply 9~36VDC Dimension (L*W*H) 100*36*65mm (2 moudule)


Rated Voltage DC 0~1000VDC Power frequency
3000VAC
Rated Current DC 100A, 200A, 300A, 400A withstand voltage

Rated voltage: 75mV Insulation resistance ≧100mΩ


Shunt
Accuracy: Class 0.2 Impulse voltage 6000V

Starting Current 0.002Ib Operating temperature: -20℃~ +55 ℃


Pulse output 1 channels, pulse constant: 1000imp/kWh Limit Temperature: -25℃~ +75 ℃
Environment
Storage temperature: -30℃~ +80 ℃
Power loss <1W
Humidity: < 95%
RS485 port
Electrostatic Discharge Immunity Test IEC61000-4-2:2001
MODBUS-RTU or DL/T645-2007 (Settable) RF Electromagnetic Field Immunity testing IEC61000-4-3:2002
Communication Electrical fast transient immunity test IEC61000-4-4:2004
Address: 1~247
EMC Standard Surge immunity test IEC61000-4-5:2005
Baud rate: 1200, 2400, 4800, 9600, 19200bps Injected Current Immunity Test IEC61000-4-6:2006
Electromagnetic emission limit Passed
IP index IP20 Voltage sag and short-time interruption Immunity testing Passed

Parameter Measurement Range Accuracy


Voltage 0-1000VDC 0.2%
Current 1% ~ 120% of rated 0.2%
Power 0~300kW 0.5%
Energy 0~999999.99kWh Class 0.5

90
1 100A Shunt
2 200A Shunt
3 300A Shunt
4 400A Shunt

P Pulse Output

Example: Model No. SPM900-1-P, which indicate the device provides with basic function and pulse output,100A shunt , MODBUS-RTU
communication protocol .

Note: Default Pulse output function, MODBUS-RTU protocol, baudrate 9600bps, settable for DL/T645-2007 protocl

10
70

SPM91 Upgrade version

50mA 70

91

11
5(6)A 5(63)A

SPM93 Upgrade version

Power Loss

200-2000
VAC VAC 70
VAC VAC

, 19200

var Mvar

MVA

12
93 3

VAC ph-N)
VAC ph-N)

13
Suitable for distribution system under 650kV
True RMS measuring parameters
Setpoint alarm for over/ under limit
PT and CT (1A/ 5A) programmable
Optional digital input & relay output
High accuracy, class 0.5s for kWh
Small size: 72* 72mm
One RS485, support Modbus-RTU protocol

SPM32 Upgrade version

Measuring real-time parameters: Setpoint alarm info—over voltage, under voltage, over current, under
Voltage--Ua, Ub, Uc, Uab, Ubc, Uca, phase angle current, over frequency, under frequency, over load, over demand
Current—Ia, Ib, Ic, I0, phase angel power, phase loss, DI status
Active Power—Pa, Pb, Pc, ∑P *Harmonic — THDi, THDu, 2~63rd harmonic
Reactive Power—Qa, Qb, Qc, ∑Q *Apparent Energy—kVAh,
Apparent Power—Sa, Sb, Sc, ∑S *Unbalance rate — Iunbal , Uunbal
Power Factor-- PFa, PFb, PFc, ∑PF *Device power on hour—DOH,
Frequency—F *Load on/ run hour—LOH, LRH
Energy—Total kWh, Total kvarh *Load impedance
Demand—Dmd for I, Dmd for P
Note: The data marked * is can read only by RS485

2 digital input
2 relay output
2 pulse output

Panel: 72 x 72 x 6 mm
Cut-out: 66.5 x 66.5 x 73.5 mm (+0.5mm)

250VAC/5A or 30VDC/5A

85~265VAC or 100~300VDC

14
Direct input line - line 10 ~ 500V, Line – neutral: 10 ~ 400V
PT primary: 650KV, PT secondary: 100-400V

CT primary: 9,999A, CT secondary: 5mA~6.5A

-1.0000~1.0000
0 ~ ±9,999MW

0 ~ ±9,999Mvar

0 ~ 9,999MVA

0~ 99,999,999.9 kWh

Voltage or current unbalance

73.50
72.00 6.00 64.00 66.50
66.50

66.50
72.00

S 2 digital input (wet contact)


SR 2 digital input (wet contact) + 2 relay output
EP 2 pulse output

Model No. SPM32-SR, it means the device provides basic measuring function, one RS485 port, 2 digital input, 2 relay output.

15
Suit for distribution system below AC 650kV
CT input 1A or 5A settable
PT and CT settable
Setpoint alarm function
Up to 63rd harmonic analysis, THD
Wiring mode 1P2W, 3P3W, 3P4W
RS485/Modbus-RTU communication protocol
Energy accuracy Class 0.5s
SPM33 Upgrade version

Measuring real-time parameters: *2~63rd harmonic

Voltage--Ua, Ub, Uc, Uab, Ubc, Uca, phase angle *Apparent Energy—kVAh,

Current—Ia, Ib, Ic, In, phase angel *Unbalance rate — Iunbal , Uunbal

Active Power—Pa, Pb, Pc, ∑P *Device power on hour—DOH,

Reactive Power—Qa, Qb, Qc, ∑Q *Load on/ run hour—LOH, LRH

Apparent Power—Sa, Sb, Sc, ∑S Setpoint alarm info—over voltage, under voltage,

Power Factor-- PFa, PFb, PFc, ∑PF over current, under current, over frequency, under

Frequency—F frequency, over load, phase loss, DI status

Energy—kWh, kvarh (total, imp. and exp.) 2 DI (wet contact), RS485

Demand—Dmd for I, P, Q, S
THD — THDi, THDu,

*Multi-tariff energy, *SOE event log,

2 relay output *Four-quadrant energy, *Max.& Min. data,

4DI + 2 relay output *History data record, *Forecast demand,

LAN port (Modbus-TCP protocol) *Monthly peak demand, *Current K factor,


*Voltage crest factor, *Current TDD,
*Displacement power factor

Note: The data marked * can be read only from communication.

1 phase 2 wires, 3 phase 3 wires, 85~265VAC or 100~300VDC


3 phase 4 wires

RS485 serial, support Modbus-RTU


Baudrate: 4800, 9600, 19200 bps
Address: 1~247
Optional RJ45, support Modbus-TCP

16
≤6 channels,
Wet contact (active status input): voltage
Status input
less than 60V is open,more than 140V is
(optional) closed,the maximum input is 300V
Optional dry contact output: DC30V

≤4 channels,
Node capacity: 250Vac/5A

AC 4KV/minute

6kV (peak), 1.2/50uS

Direct input line - line 10 ~ 500V, Line – neutral: 10 ~ 400V


0.2%
PT primary: 650KV, PT secondary: 100-400V

0.2% CT primary: 50,000A, CT secondary: 5mA~6.5A

1.0% -1.0000~1.0000

0.5% 0 ~ ±9999MW

1.0% 0 ~ ±9999Mvar

1.0% 0 ~ 9999MVA

Active energy 0.5% 0~ 99,999,999.9 kWh

2.0% 0~ 99,999,999.9 kvarh

2.0% 0~ 99,999,999.9 kVAh

Voltage or current unbalance 1.0% 0%~100%

Harmonic Class B 0%~100%

81.00
96.00 10.70 62.60 89.40
96.00

89.40

89.40

R Two relay output


T SOE event log, Multi-tariff energy, Four-quadrant energy, Max.& Min. data, History data
record, Forecast demand, Monthly peak demand, current K factor, voltage crest factor,
current TDD, Displacement power factor

E1 4 status input (wet contact) + 2 relay output


E4 4 status input (dry contact) + 2 relay output
LAN One LAN port, support Modbus-TCP protocol

Model No. SPM33-R, it means the device provides basic measuring function, one RS485 port, 2 digital input, 2 relay output.

17
18
3 status inputs ( wet contact ) + 2 relay outputs

19
120V, 220V, 240V, 277V, 398Vph-N (optional)

20
3 4

85 ~ 265VAC, or 85 ~ 265 VDC, 45 ~ 65Hz


100 ~ 420VAC, or 100 ~ 400VDC, 45 ~ 60Hz

85 ~ 265VAC, or 85 ~ 265 VDC, 45 ~ 65Hz


100 ~ 420VAC, or 100 ~ 400VDC, 45 ~ 60Hz
21
780H Power Quality Analyzer

Description
Power Quality Management System
Harmonic Analysis
Energy Supply failure analysis
Voltage Sag Source Location
Transient disturbances location

Main Function
Class A Power Quality Measurement : Harmonic and inter-harmonic, voltage deviation, frequency deviation, unbalance, fluctuation
and flicker, transient disturbances, EN50160 statistics
Class 0.2s Accuracy : Harmonic, ,fundamental harmonic, sub-harmonics energy
High Resolution Failure Record : support 1024 point/cycle, Min.tansient disturbance record for 20us
Failure Diagnose Location : support voltage sag source, harmonic source, flicker source, asymmetric source location and power
supply failure type diagnose
Full Real-time Data Measurement

Feature
With all multifunction power meter function

Class 0.2s high accuracy energy mesurement

Power quality analysis: harmonic analysis,


recod analysis and flicker analysis

Failure record : bulk memory for data record


and setpoint alarm

Failure diagnose location, 20us for transient


disturbance record

Measurment Parameters
Wave Sampling 1024 points/cycle wave
2~63rd Harmonic, harmonic ratio, phase angle, total harmonic distortion (THD),
Harmonic
Power Quality total odd / even harmonic distortion
Analysis and Inter-Harmonics 2~63rd Inter-harmonic, harmonic ratio, Total inter-harmonic distortion
location Waveform record, DO alarm, timing record, record voltage sag/ swell's start time,
Voltage Sag / Swell / Stop
stop time, duration time and their Max. and Min. value and voltage variation depth
Capture 20us circle wave transient, trigger/ DO port, waveform record, record
Transient Capture
voltage transient happen time, amplitude and durantion time etc.

22
780H Power Quality Analyzer

Unbalance Voltage, current unbalance and zero sequence unbalance

Power Quality Voltage / Frequency Deviation Setpoint alarm and record


Analysis and Repid Voltage Alteration Trigger DO point, waveform record
location Voltage Fluctuation and Flick Analysis Calculate long time flicker Plt and Short time Pst
Sag Source Location Can locate power supply side or load side abnormal and fault

Measurement Voltage 4 Channels


Channel Current 4 Channels
Voltage Phase / line / average voltage, phase angle, refresh time : 1s, 0.5s circle waveform
Current Phase / average current, phase angle, refresh time: 1s, 1 circle waveform
Active power, Reactive power,
Real-time Data Phase & total poower, refresh time: 1s, 1 circle waveform
Apperant Power
Power Factor Phase & total power factor, refresh time: 1s, 1 circle waveform
Frequency 50/60Hz, refresh time: 1s, 1 circle waveform
Positive / Negative active, reactive, apparant energy ; Positive / Negative base
Energy
wave active, reactive energy
2~31st positive active, reactive harmonic energy, Negative active, reactive
Energy Harmonic Energy
harmonic energy
History Energy Storage latest 30 days and latest 12 months history energy data
Multi-tariff energy 4 tariff, 8 time period, 2 time zone
Has fixed window and slid window record volue including: three phase current,
total active power, total reactive power, total apparant power, support real-time
Real-time Demand
demand and predict demand, Max. demand and happend time, support DI
Demand demand synchronization

Predict Demand Predict next demand circle value according to present real-time active power
value. Interval demand fixed circle: 15min.
Memory 8G
Max. / Min Record This month and last month Max./Min. value and happen time
SOE Record 1024 records, time resolution: 1ms
PQ Record 1024 records, time resolution: 1ms
Circle wave before failure is settable, Waveforme record mode as below: 1: 1024
points / circle wave @ 50 circle wave: 2: 512 points/circle wave @ 100 circle wave;
Data and Waveform Record 3: 256 points/circle wave @ 200 circle wave; 4: 128 points/circle wave @ 400
circle wave;5: 64 points/circle wave @ 800 circle wave; 6: 32 points/circle wave @
Evern Record
1600 circle wave;7: 16 points/circle wave @ 3200 circle wave

Transit Wave Record 256 piece


ITIC/SEMIF47 Curve 1 Groups
In accordance with EN 50160 power quality standard, Statistics voltage, frequency,
EN50160 Statistics Function harmonic, flicker, deviation, unbalance and voltage disturbance passed rate and
other power quality index
Mark Function Mark voltage sag/ swell/ stop etc. transit even data, statistics by customer
Digital Input (DI) 8 Channels
DI/ DO
Relay Output (DO) 4 Channels
Optocoupler Output 2 Channels
Display LCD colorful interface, display measurment value, harmonic bar chat, vetorgram,
Display
time record, I/O status, ITIC waveform etc. resolution: 640 * 480
Voltage / Frequency Deviation 2, baud rate:1200~38400bps, MODBUS-RTU protocol
Communication
Repid Voltage Alteration 1, Modbus TCP/ IEC61850 (optional), support Ethernet Gateway
Voltage Fluctuation and Flick Analysis SNTP, Modbus
Time calibration
Sag Source Location GPS pulse, IRIG-B signal

23
780H Power Quality Analyzer

Advantage
Function

PMAC780H

Normal Power Meter

Relay Protection Device

Fault Recorder Device

Note : Area means function relation

voltage
380V 10kV 35kV 110kV UP
Specially for 380V~35kV voltage level's industry and commercial building
High-density sampling frequency, can record instantaneous, transient voltage disturbance
Bulk memory function, can dynamic record each even
Class A harmonica content function, harmonic measure times with high accuracy
Powerful function, combine multifunction power meter + energy meter + power quanlity analyzer + failure recorder into one

Interface

Home Page Real-time Monitoring Evaluation Report

Real-time Waveform Vector Analysis 63rd Real-time Harmonic Analysis

SmartPQM Power Quality Management System

Overview Unbalance Transient

4
780H Power Quality Analyzer

Dimensions

Technical specification
Power Supply Communication

Rated Voltage 85~275VAC, 100~300VDC,45~65Hz RS485 port 2 Port, 2400-38400bps, Modbus-RTU protocol
Power loss <10W 1 port, Modbus TCP / IEC61850 (optional)
Ethernet Port
support Ethernet gateway
AC Input
Electrical insulation performance
Rated voltage 0~400V (400V L/N / 690V L/L)
Input Dielectric strength 2kV voltage, 1 minute (GB/T 14598)
Overload 1.2 Un, Continuous; 4Un, accept 1s
Voltage Insulation resistance No less than 100MΩ (GB/T 14598)
Power loss < 0.1VA/Phase
Impulse voltage 6kV, 1.2/50μs (GB/T 14599)
Rated voltage 5A, 1A
Input Environment
Current Overload 4In, Continuous; 10In, accept 1s
Temperature - 10℃~+55℃ Humidity 5%~95%
Power loss < 0.5VA/Phase@5A, < 0.1VA/@1A
Storage - 40℃~+85℃ Pressure 70kPa~110kPa
DI / DO
Front: IP52 Measure 3 phase 4 wire
DI 8 Channel, time resolution 1ms IP Index mode
Side & Back: IP30 3 phase 3 wire
RO1-RO4 Relay, action / return time: <10ms Electromagnetic compatibility
Breaking Capacity:250VA/30VDC,0.2A,
L/R=20ms Max. voltage 30VDC Electrostatic discharge immunity IEC6100-4-2 Class IV
DO1-DO2
Max. current 50mA Radio frequency electromagnetic radiation immunity IEC6100-4-3 Class IV
Accuracy Power loss IEC6100-4-4 Class IV
Volage/ Current ±0.1% Harmonic Class A Rated voltage IEC6100-4-5 Class IV
Active / Reactive / Overload IEC6100-4-8 Class IV
±0.2% Voltage Unbalance Rate ±0.1%
Apparant power
Mechanical Character
Active energy Class 0.2s Current Unbalance Rate ±0.5%
Vibration response Class I (GB/T 11287)
Reactive energy Class 2 Voltage Deviation ±0.1%
Vibration durable Class I (GB/T 11287)
Power factor ±0.5% Frequency Deviation ±0.005Hz
Impact response Class I (GB/T 14537)
Frequency ±0.005Hz Fliker ±5%
Collision response Class I (GB/T 14537)

Order Information
PMAC780H

V1 3*220/380V (direct), 5A
V2 3*220/380V (direct), 1A
V3 3*57.7/100V (via PT),5A
V4 3*57.7/100V (via PT),1A
V5 3*400/690V (direct), 5A
V6 3*400/690V (direct), 1A

SW External power supply (Wet Contact) digital input


SD No external power supply (Dry contact) digital input

CP IEC61850 Protocol

Note : PMAC780H default with Ethernet port, if select CP function, then support IEC61850 protocol, otherwise it won't support.
5
801A Motor Protection Controller Relay

Application
Lower Voltage MCC
Integrated process and electrical control

Features
Suit for motors rated voltage 380V AC or 660V AC
Small Size compact design with LCD display
Integrated measurement, protection and control functions
Main module provide 9 DIs (digital input) and 5 DOs (digital output)
Optional 1 analog (4~20mA) input or 1 leakage current protection
Small size and configuration.
Easy installation. Proper for 35mm DIN rail.
35mm DIN rail mounting
Safety, Excellent quality and multifunction

Function
Full Protection Function Full Protection Function
Pre-start: Wiring checking, fault treatment and confirmation Starting Control: 32 event record support protection mode, direct
Starting Process: Monitor the starting time period and current start mode, star/delta start mode, autotransformer start mode

Running Process: 18 protections, like Overload protection, TE Re-star Control: Anti sway electric , under-voltage re-start,
time protection, Over-current protection, Phase failure protection... auto re-start etc. function

Motor Life Cycle Management Operation Control: Support locan control, DCS control,
communication control
Running Management
Other Function
Event Record: 32 event record with timescale, full range record
for motor operation, fault record and so on Multiple Control: Modbus-RTU / Profibus-DP
Time management and authority management
Function Configuration
Start Overtime Yes I, In, I_avg., I_unbal. Yes
Measure
Start Over-current Yes U, P, Q, PF, F, kwh, I△n Yes
Overcurrent Yes Starting Control Yes
Current unbalance Yes Control Re-start Control Yes
Overload Yes Self-start control Yes
Underload Yes DI 9 DI in main module Standard
Underload Yes DO 5 DO in main module Standard

Short circuit Yes MODBUS-RTU Standard


Earth Fault Yes COM Profibus – DP
Optional
Eex e overload (tE) Yes or another MODBUS-RTU
Protection
External fault Yes AO One 4~20mA DC analog output Standard
Overvoltage Yes AI One 4~20mA DC analog input Standard
Under voltage Yes SOE Latest 32 event records Standard
Under power Yes Total running time period Standard
Phase Sequence error Yes Present running time Standard
TV open circuit Yes Total stop operation time Standard

Wiring Checking Yes Present stop operation time Standard


SOE
Overflow fault Yes Total stop operation time Standard
Temperature (PTC/NTC) Optional Total trip times Standard
Leakage current Optional Longest starting time Standard
Analog Input Optional Max. starting current Standard

6
801A Motor Protection Controller Relay

PMAC801A Included
75.0

99.0
Start Run Alarm Trip Com PMAC801A
Run
Com

55.0
119.5
PMAC801A

110.0
Fault

External port
Profibus-DP Start A Start B Stop Reset

PMAC801A Main Moudle Display Module (LCD )

Optional Leakage CT

Ø4
5

76
Φ4

67
76

Current Transformer Current Transformer Current Transformer Leakage Current Transformer


(for <100A) (for 250A, 400A) (for 500A, 820A) (for 100A~800A)

PMAC801A Includes
PMAC801A 3 4 2 2A (For motor: 0.1 – 1.1 kW)
6.3 6.3A (For motor: 1.1 – 3.1 kW)
10 10A (For motor: 3.1 – 5.3 kW)
25 25A (For motor: 5.3 – 11 kW)
50 50A (For motor: 11 – 22 kW)
100 100A (For motor: 22 – 45 kW)
250 250A (For motor: 45 – 132 kW)
400 400A (For motor: 132 – 211 kW)
500 500A (For motor: 211 – 264 kW)
820 820A (For motor: > 264kW)

P Profibus-DP
F Dual Modbus_RTU

C Leakage current protection


A One 4~20mA Analog Input
C & A can't not select at the same time

T 1 Temperature input
Can not select together with F (dual Modbus-RTU)

Notes:
1. Standard PMAC801A including main module, display module, current transformer, 1 RS485, 1 Analog output
2. If customer need leakage current protection, please select leakage current transformer
3. Standard wire for current transfomer is 1.5m
4. Main module and display module connect with a standard wire (1m), please mention before place the order if you need longer wire (3.5m),
5. Standard main module has protection functions: start overtime, start overcurrent, overload, overcurrent, Eex e overload (tE), phase failure,
current unbalance, short circuit, earth fault, underload, undervoltage, underpower, external fault, phase sequence error, TV open circuit,
overflow fault

7
Charter 2 Multi-Channel Power Meter
SPM20 AC Multi-Channel Energy Meter

9
SPM20 AC Multi-Channel Energy Meter

45 ~ 65Hz

30
SPM20 AC Multi-Channel Energy Meter

SPM20-CTRL P/2W & 3P/4W

SPM20-CTC

SPM20-CTO

31
SPM20 D DC Multi-Channel Energy Meter

Description
SPM20-D is specially design for telecommunication base station application to calculating power consumption, measuring DC device electricity.

It is the smallest DC multi-channel Energy Meter with compact design, consists of main module and measure module. Very user friendly installation

for simplize the installation at size.

Application
Telecommunication BTS Billing System

DC Load Management

Feature
Small Size - Can be install at the closest point, integrate in existing space

Easy Installation - Consist of main module and measur module, connected by PLbus Daisy chain bus topology and RJ12 port,

measure module straight insert into the circuit breaker

High Accuracy - Voltage & Current class 0.5, kWh class 1.0

- 48VDC Power Supply - Special design for Telecom BTS application

Wide Measurement Range - Max. support 63A direct connect, no need for extra Hall Sensor or Shunt

Multi Circuit - Support 12 single phase circuit

Function
Measure -- Voltage, Current, Power, Energy (input / output / total)

Alarm - Voltage limit alarm (high limit/ low limit), Current limit alarm (high limit), Communication failure alarm

Communication - Modbus-RTU protocol, RS485 port

Technical Specification
SPM20-D-M: Main Module

32
SPM20 D DC Multi-Channel Energy Meter

SPM20-D-C: Measure Module

Accuracy Environment & Temperature

Typical Connection

Order Information

33
PMAC211 AC Multi-Channel Energy Meter

,12x1 phase AC measuring

34
PMAC211 AC Multi-Channel Energy Meter

35
Charter 3 System Solution
xGate6-Lite Smart Gateway

Feature
Powerful Data Collecting & Forwarding Function
Automation collection and multi transmit mode, support Modbus_TCP,
JSON, XML, HTTP(s), can connect to various cloud software and system.

Effective and Reliable Data Storage and Management


Build-in SQL, Two-way communication and packet verification, support
JSON & XML data packet continue transferring from breakpoint.

Convenient Batch Configuration, Debugging & Update


To suit distributed deployment &Ethernet management in IoT system,
especially large scale system with cloud management.

Support Modbus_RTU, Modbus_TCP, DLT645, IEC103, Build-in SQL data base


CJT188 device Max. 12 months Historical data & alarm records storage (hh:mm:ss)
Max. 1,000 data points, Max. 64 devices SMS Message Record
Max.2 RS485 ports, each port support ≦32 slave devices Standard 8GB TF card (Max 32GB Micro -SD TF card)

Alarm Funtion
4G wireless data transmit SMS Alarm
Max. 1,000 data points, Max. 64 devices Multiple alarm setting for each device
Support HTTP(s) XML and JSON forwarding format Real-time alarm data transmit

xGate-Lite

4G

xGate-Lite
4G

7
xGate6-Lite Smart Gateway

Item Parameter Description


Port No. / Port Type R2 RS485 Port, Support Modbus_RTU, Modbus_TCP, DLT645, IEC103, CJT188 protocol

Baud rate 1200bps ~ 115200bps (Optional)


COM Port
Data Transmit Mode Master Mode

Support Connect IED Quantity ≤32pcs ( 2x RS485, Max 64 Slave device)

TF Port (Standard) Port No. / Port Type 1 Port, Standard 8G (Max. 32GB Micro-SD TF card)

Ethernet Port
Port No. / Port Type 1 Ports, 10/100M
(Standard)

Port No. / Port Type 1 Port, 4G SIM card (Dimension 15mmX25mm)

SIM Port
• LTE FDD Band 1,3,5,8 • LTE TDD Band 34,38,39,40
Network
• WCDMA Band 1,8 • GSM 900/1800MHZ

CPU: Mipsel 580MHz Color: Black

Memory: DDR 128MB 4 Indicate Light: indicate Run, COM1, COM2,


Hardware Structure
Flash: Nor flash 32MB Installation: DIN Rail Mounting

MTBF: >=50,000 hours Size(L*W*H): 98.2*63*68mm

Input: AC85-265V or DC80-300V Working Temperature -15℃ ~ +55℃


Power supply Environment
Consumption: < 5W Storage -25℃ ~+ 70℃, 5~95%@non-condensing

Oscillatory waves immunity test


Electrostatic discharge immunity test
Radiated radio-frequency electromagnetic field immunity (RFEMS)
Testing and measurement techniques - Electrical fast transient/burst immunity test
Surge immunity test
Radio frequency interference immunity
Power frequency magnetic field immunity test
Electromagnetic emission limits
Power frequency immunity

68.00
63.00 63.00

RUN COM1 COM2


94.00

98.20

DIN Rail 35mm

Lite

2CL 2 RS485,Cellular Network (Support 4G), 1 Ethernet Port

Customer order xGate6-Lite-2CL, it means the device has standard 1 8GB TF port, 1 10/100M Ethernet ports,
Cellular Network(Support 4G) and other basic function.

8
32

SMS alarm notice

9
40
32

• TDD-LTE B38/B39/B40/B41 *
• FDD-LTE B1/B3/B8
Wireless xGate6-2ZL • TD-SCDMA B34/B39
Communication xGate6-4CL
Port • UMTS/HSDPA/HSPA+ B1/B8
• GSM/GPRS/EDGE 900/1800 MHz
• 1 SIM Port, SIM card (Dimension 15mmX25mm)

AI / Type 2 Ports ( optional ) / DC 4-20mA


DI / Type 4 Ports ( optional ) / Dry Contact

DO / Type 1 Port ( optional ) / AC220V/5A DC30V/5A


/ AC85~265V or DC100~300V (Optional)

* Notice : Customer need to double check with local operator to see if the GPRS frequency selection is support or not.
41
2ZL 2 RS485, 4 DI, 2 AI, 1 DO, Cellular Network (Support 2G / 3G / 4G)
4CL 4 RS485, Cellular Network (Support 2G / 3G / 4G)

P1 AC 85 ~265V or DC 100~300V
P2 DC18~36V

Customer order xGate6-2ZL-P2, it means the device has standard 1 USB 2.0 port, 1 8GB TF port, 2 10/100M Ethernet ports,
with optional function 2 RS485 ports, 4 DI (Dry contact), 2 AI (4~20mA), 1 DO and Cellular Network (Support 4G), power
supply DC18~36V.

42
Charter 4 Current Transformer
CTSB Split Core Current Transformers

Description
The CTSB series of split core style current transformers are
designed for fast and easy installation. The split core design
permits non-contact current measurements through magnetic
Ro H S
field induction without disconnecting cables or busbar circuits
for CT installation. This method permits a safer, easier and
portable current measurement.

Application
Current, power, energy, monitoring devices

Power Factor Correction devices

Active Power Filter

Feature
Low cost

5 standard sizes

Split core design, safer, easier installation, and portable

Technical specification D
D 9
F A F
Rated Primary current AC 100-5000A

G
Rated Secondary current AC 5A & 1A (Optional)
Rated load 1, 2.5, 5.0, 10, 30VA
Accuracy 0.5, 1.0, 3.0 Class

B
E
Rated security coefficient FS<5
Case Material UL flame retardant rating 94-V0
Frequency Range 50~400Hz
Operating Temperature -15 ℃ to 50℃
I

Standard IEC 60044-1


C
Devices for centering
the busbar fixing
Accessories Supplied with feet for base mounting if required
Highest Voltage for Equipment Um (rms) AC 720 V
Rated Power-Frequency Withstand Voltage (rms) AC 3000V
32
50
65

Order Information
CTSB / 5A
0203 20*30mm
0508 50*80mm
0512 50*120mm
0812 80*120mm
0816 80*160mm

Rated input current

44
CTSB Split Core Current Transformers

Outline Dimension And Performances

Burden(VA) Weight
Model A B C D E F G H I Ratio
Class0.5 Class1.0 Class3.0 (kg)

100 : 5 -- -- 1.5
150 : 5 -- -- 3.0
200 : 5 -- 1.5 2.5
CTSB0203 21 31 51 89 105 34 42 40 32 0.78
250 : 5 -- 1.5 3.75
300 : 5 1.5 3.75 5.0
400 : 5 2.5 5.0 10.0
250 : 5 -- -- 3.75
300 : 5 -- 2.5 5.0
400 : 5 2.5 3.75 7.5
CTSB0508 50 80 78 114 145 32 32 32 33 500 : 5 2.5 5.0 10.0 0.9
600 : 5 2.5 5.0 15.0
750 : 5 3.75 7.5 15.0
1000 : 5 5.0 10.0 20.0
600 : 5 -- 2.5 3.75
750 : 5 2.5 3.75 7.5
1000 : 5 5.0 7.5 10.0
1250 : 5 5.0 7.5 12.5
CTSB0512 55 125 108 143 191 44 36 49 30 2.2
1500 : 5 7.5 10.0 15.0
2000 : 5 10.0 10.0 20.0
2500 : 5 15.0 20.0 25.0
3000 : 5 15.0 20.0 30.0
500 : 5 2.5 5.0 10.0
600 : 5 2.5 5.0 15.0
750 : 5 3.75 7.5 15.0
CTSB0812 80 120 108 144 185 32 32 32 33 1.25
1000 : 5 5.0 10.0 20.0
1250 : 5 7.5 12.5 20.0
1500 : 5 7.5 15.0 25.0
500 : 5 2.5 5.0 10.0
600 : 5 3.75 5.0 15.0
750 : 5 5.0 10.0 15.0
1000 : 5 10.0 15.0 20.0
1250 : 5 12.5 15.0 25.0
CTSB0816 80 160 120 176 247 48 48 52 38 1500 : 5 15.0 20.0 25.0 4.4
2000 : 5 15.0 20.0 30.0
2500 : 5 15.0 20.0 30.0
3000 : 5 20.0 25.0 30.0
4000 : 5 20.0 25.0 30.0
5000 : 5 20.0 30.0 40.0

45
BH-0.66 Series Ⅰ Current Transformers

Feature
Rectangular shape with stepped window to fit bus bar as well
as single or multi-cables.Main applications are metering and
instrumentation.
Full complete ratio range with six sizes for more application
choices.With its enhanced burden feature,30*30I's rated
burden is able to reach 5 to 10VA with the primary current
lower than 100A,when the turns of the cable going through the
core are 20 to 3.

Order Information

BH 0.66 Ⅰ
0.66 Insulation Level(kV)

30
40
60 Size
80
100

Ⅰ Model Series Type

Dimension

Outline Window Installational Installational


Dimension Dimension Dimension Method
Model A B
W H D a e d Ф
M N M N

30Ⅰ 60 78 34 31 11 12 23 32 58 40 57 ABCE
H
e

40Ⅰ 75 98 43.5 42 11 13 30.5 45 58 52 66 ABCE


a
60Ⅰ 102 125 46 62 21 23 45 42 58 56 69 ABCE

M 80Ⅰ 118 138 45 81.5 10.5 30 52 60 58 A B E


D
W N
100Ⅰ 146 154 45 101 10.5 31.5 62 80 58 A B E

46
BH-0.66 Series Ⅰ Current Transformers

Technical Parameters

Model 30Ⅰ 40Ⅰ 60Ⅰ 80Ⅰ 100Ⅰ


MaxCable Size 23 30.5 45 52 62
60*10/1 80*10/1 100*10/1
Max busbar Size / QTY 30*10/1 30*10/1 60*6/1-2 60*10/1-2 80*10/1-2
Accuracy Class 0.5 1.0 0.5 1.0 0.2 0.5 0.2 0.5 0.2 0.5

Primary Current / Secondary Current (A) Rated Burden(VA)

15 5 2.5(5) 2.5(5)

20 5 2.5(4) 2.5(4)

25 5 2.5(3) 2.5(3)

30 5 2.5(3) 2.5(3)

40 5 2.5(2) 2.5(2)

50 5 2.5(2) 2.5(2)

60 5 2.5(2) 2.5(2)

75 5 2.5 2.5

100 5 2.5 2.5

150 5 2.5 2.5 5

200 5 5 5

250 5 5 5

300 5 5 5 5 5

400 5 5 5 5 5

500 5 10 5 10 10

600 5 10 5 10 5 10 5 10

750 (800) 5 10 5 10 5 10 5 10

1000 5 15 20 15 20 10 20

1200 (1250) 5 20 20 20

1500 5 20 20 20

2000 5 20 20 20

2500 5 30 30

3000 5 30

Ordering Instruction
1.Please specify the model name,transformation ratio,accuracy class,rated burden,and required installation method,when placing a purchase
order.
2.If there is any special requirements,please contact us,so we can custom make upon request.
3.Unless specified in the order,data in black is standrd,data in red is customized.
4.The numbers in the brackets indicate the times of the cable going through the core.

47
Tel: +86-756-3629688,+86-756-6931888 ext 6088
Fax: +86-756-3629700
marketing@pmac.com.cn