80H Quality Analyzer 22
System Solution
xGate6-Lite Smart Gateway 37
39
Current Transformer
3 30 Channel 12 Channel
(NO “F”)
IEC61850 Protocol
Charter 1
Power Meter
Energy Meter
Motor Protection Controller
EGO700 IoT Multifunction Power Meter
4G / LoRa / RS485
System Structure
4G
LoRa
RS485
Internet
P2P Remote
4G Operator Maintenance
6
EGO700 IoT Multifunction Power Meter
Voltage, current, active power, reactive power, Three phase voltage/current, 63rd harmonic analysis,
apparent power, power factor, frequency, active voltage/current unbalance
energy, reactive energy , apparent energy, voltage
and current phase angle, cable temperature,
residual current, switch detection Demand Calculation
Latest 10 years, 12 months, 31 days historical Maximum and real-time demand of power and current
energy Real-time demand, daily and monthly max. demand
Setpoint Alarm
Communication
Support alarming of over-voltage, under-voltage, over-current,
Standard 1 RS485 and 1 infrared communication
under-current, lost phase, power over limit, over temperature, leakage
4G / LoRa optional, support Modbus, Http, Mqtt
current and power failure with SOE time record.
communication etc, support Modbus-RTU and
Modbus-TCP, register is definable
Support break-point transfer
7
EGO700 IoT Multifunction Power Meter
35mm Din-Rail
8
EGO700 IoT Multifunction Power Meter
EGO700
RS485 —— 1 x RS485
9
0 C Energy Meter
Basic Function
Real-time measure one circuit DC voltage, current, power , kWh
High accuracy: Class 0.5
One LED indicate pulse output
RS485 port, MODBUS-RTU or DL/T645 protocol (optional)
35mm DIN rail installing, standard DIN ED5002
Shunt: 100A, 200A, 300A, 400A
90
1 100A Shunt
2 200A Shunt
3 300A Shunt
4 400A Shunt
P Pulse Output
Example: Model No. SPM900-1-P, which indicate the device provides with basic function and pulse output,100A shunt , MODBUS-RTU
communication protocol .
Note: Default Pulse output function, MODBUS-RTU protocol, baudrate 9600bps, settable for DL/T645-2007 protocl
10
70
50mA 70
91
11
5(6)A 5(63)A
Power Loss
200-2000
VAC VAC 70
VAC VAC
, 19200
var Mvar
MVA
12
93 3
VAC ph-N)
VAC ph-N)
13
Suitable for distribution system under 650kV
True RMS measuring parameters
Setpoint alarm for over/ under limit
PT and CT (1A/ 5A) programmable
Optional digital input & relay output
High accuracy, class 0.5s for kWh
Small size: 72* 72mm
One RS485, support Modbus-RTU protocol
Measuring real-time parameters: Setpoint alarm info—over voltage, under voltage, over current, under
Voltage--Ua, Ub, Uc, Uab, Ubc, Uca, phase angle current, over frequency, under frequency, over load, over demand
Current—Ia, Ib, Ic, I0, phase angel power, phase loss, DI status
Active Power—Pa, Pb, Pc, ∑P *Harmonic — THDi, THDu, 2~63rd harmonic
Reactive Power—Qa, Qb, Qc, ∑Q *Apparent Energy—kVAh,
Apparent Power—Sa, Sb, Sc, ∑S *Unbalance rate — Iunbal , Uunbal
Power Factor-- PFa, PFb, PFc, ∑PF *Device power on hour—DOH,
Frequency—F *Load on/ run hour—LOH, LRH
Energy—Total kWh, Total kvarh *Load impedance
Demand—Dmd for I, Dmd for P
Note: The data marked * is can read only by RS485
2 digital input
2 relay output
2 pulse output
Panel: 72 x 72 x 6 mm
Cut-out: 66.5 x 66.5 x 73.5 mm (+0.5mm)
250VAC/5A or 30VDC/5A
85~265VAC or 100~300VDC
14
Direct input line - line 10 ~ 500V, Line – neutral: 10 ~ 400V
PT primary: 650KV, PT secondary: 100-400V
-1.0000~1.0000
0 ~ ±9,999MW
0 ~ ±9,999Mvar
0 ~ 9,999MVA
0~ 99,999,999.9 kWh
73.50
72.00 6.00 64.00 66.50
66.50
66.50
72.00
Model No. SPM32-SR, it means the device provides basic measuring function, one RS485 port, 2 digital input, 2 relay output.
15
Suit for distribution system below AC 650kV
CT input 1A or 5A settable
PT and CT settable
Setpoint alarm function
Up to 63rd harmonic analysis, THD
Wiring mode 1P2W, 3P3W, 3P4W
RS485/Modbus-RTU communication protocol
Energy accuracy Class 0.5s
SPM33 Upgrade version
Voltage--Ua, Ub, Uc, Uab, Ubc, Uca, phase angle *Apparent Energy—kVAh,
Current—Ia, Ib, Ic, In, phase angel *Unbalance rate — Iunbal , Uunbal
Apparent Power—Sa, Sb, Sc, ∑S Setpoint alarm info—over voltage, under voltage,
Power Factor-- PFa, PFb, PFc, ∑PF over current, under current, over frequency, under
Demand—Dmd for I, P, Q, S
THD — THDi, THDu,
16
≤6 channels,
Wet contact (active status input): voltage
Status input
less than 60V is open,more than 140V is
(optional) closed,the maximum input is 300V
Optional dry contact output: DC30V
≤4 channels,
Node capacity: 250Vac/5A
AC 4KV/minute
1.0% -1.0000~1.0000
0.5% 0 ~ ±9999MW
1.0% 0 ~ ±9999Mvar
1.0% 0 ~ 9999MVA
81.00
96.00 10.70 62.60 89.40
96.00
89.40
89.40
Model No. SPM33-R, it means the device provides basic measuring function, one RS485 port, 2 digital input, 2 relay output.
17
18
3 status inputs ( wet contact ) + 2 relay outputs
19
120V, 220V, 240V, 277V, 398Vph-N (optional)
20
3 4
Description
Power Quality Management System
Harmonic Analysis
Energy Supply failure analysis
Voltage Sag Source Location
Transient disturbances location
Main Function
Class A Power Quality Measurement : Harmonic and inter-harmonic, voltage deviation, frequency deviation, unbalance, fluctuation
and flicker, transient disturbances, EN50160 statistics
Class 0.2s Accuracy : Harmonic, ,fundamental harmonic, sub-harmonics energy
High Resolution Failure Record : support 1024 point/cycle, Min.tansient disturbance record for 20us
Failure Diagnose Location : support voltage sag source, harmonic source, flicker source, asymmetric source location and power
supply failure type diagnose
Full Real-time Data Measurement
Feature
With all multifunction power meter function
Measurment Parameters
Wave Sampling 1024 points/cycle wave
2~63rd Harmonic, harmonic ratio, phase angle, total harmonic distortion (THD),
Harmonic
Power Quality total odd / even harmonic distortion
Analysis and Inter-Harmonics 2~63rd Inter-harmonic, harmonic ratio, Total inter-harmonic distortion
location Waveform record, DO alarm, timing record, record voltage sag/ swell's start time,
Voltage Sag / Swell / Stop
stop time, duration time and their Max. and Min. value and voltage variation depth
Capture 20us circle wave transient, trigger/ DO port, waveform record, record
Transient Capture
voltage transient happen time, amplitude and durantion time etc.
22
780H Power Quality Analyzer
Predict Demand Predict next demand circle value according to present real-time active power
value. Interval demand fixed circle: 15min.
Memory 8G
Max. / Min Record This month and last month Max./Min. value and happen time
SOE Record 1024 records, time resolution: 1ms
PQ Record 1024 records, time resolution: 1ms
Circle wave before failure is settable, Waveforme record mode as below: 1: 1024
points / circle wave @ 50 circle wave: 2: 512 points/circle wave @ 100 circle wave;
Data and Waveform Record 3: 256 points/circle wave @ 200 circle wave; 4: 128 points/circle wave @ 400
circle wave;5: 64 points/circle wave @ 800 circle wave; 6: 32 points/circle wave @
Evern Record
1600 circle wave;7: 16 points/circle wave @ 3200 circle wave
23
780H Power Quality Analyzer
Advantage
Function
PMAC780H
voltage
380V 10kV 35kV 110kV UP
Specially for 380V~35kV voltage level's industry and commercial building
High-density sampling frequency, can record instantaneous, transient voltage disturbance
Bulk memory function, can dynamic record each even
Class A harmonica content function, harmonic measure times with high accuracy
Powerful function, combine multifunction power meter + energy meter + power quanlity analyzer + failure recorder into one
Interface
4
780H Power Quality Analyzer
Dimensions
Technical specification
Power Supply Communication
Rated Voltage 85~275VAC, 100~300VDC,45~65Hz RS485 port 2 Port, 2400-38400bps, Modbus-RTU protocol
Power loss <10W 1 port, Modbus TCP / IEC61850 (optional)
Ethernet Port
support Ethernet gateway
AC Input
Electrical insulation performance
Rated voltage 0~400V (400V L/N / 690V L/L)
Input Dielectric strength 2kV voltage, 1 minute (GB/T 14598)
Overload 1.2 Un, Continuous; 4Un, accept 1s
Voltage Insulation resistance No less than 100MΩ (GB/T 14598)
Power loss < 0.1VA/Phase
Impulse voltage 6kV, 1.2/50μs (GB/T 14599)
Rated voltage 5A, 1A
Input Environment
Current Overload 4In, Continuous; 10In, accept 1s
Temperature - 10℃~+55℃ Humidity 5%~95%
Power loss < 0.5VA/Phase@5A, < 0.1VA/@1A
Storage - 40℃~+85℃ Pressure 70kPa~110kPa
DI / DO
Front: IP52 Measure 3 phase 4 wire
DI 8 Channel, time resolution 1ms IP Index mode
Side & Back: IP30 3 phase 3 wire
RO1-RO4 Relay, action / return time: <10ms Electromagnetic compatibility
Breaking Capacity:250VA/30VDC,0.2A,
L/R=20ms Max. voltage 30VDC Electrostatic discharge immunity IEC6100-4-2 Class IV
DO1-DO2
Max. current 50mA Radio frequency electromagnetic radiation immunity IEC6100-4-3 Class IV
Accuracy Power loss IEC6100-4-4 Class IV
Volage/ Current ±0.1% Harmonic Class A Rated voltage IEC6100-4-5 Class IV
Active / Reactive / Overload IEC6100-4-8 Class IV
±0.2% Voltage Unbalance Rate ±0.1%
Apparant power
Mechanical Character
Active energy Class 0.2s Current Unbalance Rate ±0.5%
Vibration response Class I (GB/T 11287)
Reactive energy Class 2 Voltage Deviation ±0.1%
Vibration durable Class I (GB/T 11287)
Power factor ±0.5% Frequency Deviation ±0.005Hz
Impact response Class I (GB/T 14537)
Frequency ±0.005Hz Fliker ±5%
Collision response Class I (GB/T 14537)
Order Information
PMAC780H
V1 3*220/380V (direct), 5A
V2 3*220/380V (direct), 1A
V3 3*57.7/100V (via PT),5A
V4 3*57.7/100V (via PT),1A
V5 3*400/690V (direct), 5A
V6 3*400/690V (direct), 1A
CP IEC61850 Protocol
Note : PMAC780H default with Ethernet port, if select CP function, then support IEC61850 protocol, otherwise it won't support.
5
801A Motor Protection Controller Relay
Application
Lower Voltage MCC
Integrated process and electrical control
Features
Suit for motors rated voltage 380V AC or 660V AC
Small Size compact design with LCD display
Integrated measurement, protection and control functions
Main module provide 9 DIs (digital input) and 5 DOs (digital output)
Optional 1 analog (4~20mA) input or 1 leakage current protection
Small size and configuration.
Easy installation. Proper for 35mm DIN rail.
35mm DIN rail mounting
Safety, Excellent quality and multifunction
Function
Full Protection Function Full Protection Function
Pre-start: Wiring checking, fault treatment and confirmation Starting Control: 32 event record support protection mode, direct
Starting Process: Monitor the starting time period and current start mode, star/delta start mode, autotransformer start mode
Running Process: 18 protections, like Overload protection, TE Re-star Control: Anti sway electric , under-voltage re-start,
time protection, Over-current protection, Phase failure protection... auto re-start etc. function
Motor Life Cycle Management Operation Control: Support locan control, DCS control,
communication control
Running Management
Other Function
Event Record: 32 event record with timescale, full range record
for motor operation, fault record and so on Multiple Control: Modbus-RTU / Profibus-DP
Time management and authority management
Function Configuration
Start Overtime Yes I, In, I_avg., I_unbal. Yes
Measure
Start Over-current Yes U, P, Q, PF, F, kwh, I△n Yes
Overcurrent Yes Starting Control Yes
Current unbalance Yes Control Re-start Control Yes
Overload Yes Self-start control Yes
Underload Yes DI 9 DI in main module Standard
Underload Yes DO 5 DO in main module Standard
6
801A Motor Protection Controller Relay
PMAC801A Included
75.0
99.0
Start Run Alarm Trip Com PMAC801A
Run
Com
55.0
119.5
PMAC801A
110.0
Fault
External port
Profibus-DP Start A Start B Stop Reset
Optional Leakage CT
Ø4
5
76
Φ4
67
76
PMAC801A Includes
PMAC801A 3 4 2 2A (For motor: 0.1 – 1.1 kW)
6.3 6.3A (For motor: 1.1 – 3.1 kW)
10 10A (For motor: 3.1 – 5.3 kW)
25 25A (For motor: 5.3 – 11 kW)
50 50A (For motor: 11 – 22 kW)
100 100A (For motor: 22 – 45 kW)
250 250A (For motor: 45 – 132 kW)
400 400A (For motor: 132 – 211 kW)
500 500A (For motor: 211 – 264 kW)
820 820A (For motor: > 264kW)
P Profibus-DP
F Dual Modbus_RTU
T 1 Temperature input
Can not select together with F (dual Modbus-RTU)
Notes:
1. Standard PMAC801A including main module, display module, current transformer, 1 RS485, 1 Analog output
2. If customer need leakage current protection, please select leakage current transformer
3. Standard wire for current transfomer is 1.5m
4. Main module and display module connect with a standard wire (1m), please mention before place the order if you need longer wire (3.5m),
5. Standard main module has protection functions: start overtime, start overcurrent, overload, overcurrent, Eex e overload (tE), phase failure,
current unbalance, short circuit, earth fault, underload, undervoltage, underpower, external fault, phase sequence error, TV open circuit,
overflow fault
7
Charter 2 Multi-Channel Power Meter
SPM20 AC Multi-Channel Energy Meter
9
SPM20 AC Multi-Channel Energy Meter
45 ~ 65Hz
30
SPM20 AC Multi-Channel Energy Meter
SPM20-CTC
SPM20-CTO
31
SPM20 D DC Multi-Channel Energy Meter
Description
SPM20-D is specially design for telecommunication base station application to calculating power consumption, measuring DC device electricity.
It is the smallest DC multi-channel Energy Meter with compact design, consists of main module and measure module. Very user friendly installation
Application
Telecommunication BTS Billing System
DC Load Management
Feature
Small Size - Can be install at the closest point, integrate in existing space
Easy Installation - Consist of main module and measur module, connected by PLbus Daisy chain bus topology and RJ12 port,
High Accuracy - Voltage & Current class 0.5, kWh class 1.0
Wide Measurement Range - Max. support 63A direct connect, no need for extra Hall Sensor or Shunt
Function
Measure -- Voltage, Current, Power, Energy (input / output / total)
Alarm - Voltage limit alarm (high limit/ low limit), Current limit alarm (high limit), Communication failure alarm
Technical Specification
SPM20-D-M: Main Module
32
SPM20 D DC Multi-Channel Energy Meter
Typical Connection
Order Information
33
PMAC211 AC Multi-Channel Energy Meter
34
PMAC211 AC Multi-Channel Energy Meter
35
Charter 3 System Solution
xGate6-Lite Smart Gateway
Feature
Powerful Data Collecting & Forwarding Function
Automation collection and multi transmit mode, support Modbus_TCP,
JSON, XML, HTTP(s), can connect to various cloud software and system.
Alarm Funtion
4G wireless data transmit SMS Alarm
Max. 1,000 data points, Max. 64 devices Multiple alarm setting for each device
Support HTTP(s) XML and JSON forwarding format Real-time alarm data transmit
xGate-Lite
4G
xGate-Lite
4G
7
xGate6-Lite Smart Gateway
TF Port (Standard) Port No. / Port Type 1 Port, Standard 8G (Max. 32GB Micro-SD TF card)
Ethernet Port
Port No. / Port Type 1 Ports, 10/100M
(Standard)
SIM Port
• LTE FDD Band 1,3,5,8 • LTE TDD Band 34,38,39,40
Network
• WCDMA Band 1,8 • GSM 900/1800MHZ
68.00
63.00 63.00
98.20
Lite
Customer order xGate6-Lite-2CL, it means the device has standard 1 8GB TF port, 1 10/100M Ethernet ports,
Cellular Network(Support 4G) and other basic function.
8
32
9
40
32
• TDD-LTE B38/B39/B40/B41 *
• FDD-LTE B1/B3/B8
Wireless xGate6-2ZL • TD-SCDMA B34/B39
Communication xGate6-4CL
Port • UMTS/HSDPA/HSPA+ B1/B8
• GSM/GPRS/EDGE 900/1800 MHz
• 1 SIM Port, SIM card (Dimension 15mmX25mm)
* Notice : Customer need to double check with local operator to see if the GPRS frequency selection is support or not.
41
2ZL 2 RS485, 4 DI, 2 AI, 1 DO, Cellular Network (Support 2G / 3G / 4G)
4CL 4 RS485, Cellular Network (Support 2G / 3G / 4G)
P1 AC 85 ~265V or DC 100~300V
P2 DC18~36V
Customer order xGate6-2ZL-P2, it means the device has standard 1 USB 2.0 port, 1 8GB TF port, 2 10/100M Ethernet ports,
with optional function 2 RS485 ports, 4 DI (Dry contact), 2 AI (4~20mA), 1 DO and Cellular Network (Support 4G), power
supply DC18~36V.
42
Charter 4 Current Transformer
CTSB Split Core Current Transformers
Description
The CTSB series of split core style current transformers are
designed for fast and easy installation. The split core design
permits non-contact current measurements through magnetic
Ro H S
field induction without disconnecting cables or busbar circuits
for CT installation. This method permits a safer, easier and
portable current measurement.
Application
Current, power, energy, monitoring devices
Feature
Low cost
5 standard sizes
Technical specification D
D 9
F A F
Rated Primary current AC 100-5000A
G
Rated Secondary current AC 5A & 1A (Optional)
Rated load 1, 2.5, 5.0, 10, 30VA
Accuracy 0.5, 1.0, 3.0 Class
B
E
Rated security coefficient FS<5
Case Material UL flame retardant rating 94-V0
Frequency Range 50~400Hz
Operating Temperature -15 ℃ to 50℃
I
Order Information
CTSB / 5A
0203 20*30mm
0508 50*80mm
0512 50*120mm
0812 80*120mm
0816 80*160mm
44
CTSB Split Core Current Transformers
Burden(VA) Weight
Model A B C D E F G H I Ratio
Class0.5 Class1.0 Class3.0 (kg)
100 : 5 -- -- 1.5
150 : 5 -- -- 3.0
200 : 5 -- 1.5 2.5
CTSB0203 21 31 51 89 105 34 42 40 32 0.78
250 : 5 -- 1.5 3.75
300 : 5 1.5 3.75 5.0
400 : 5 2.5 5.0 10.0
250 : 5 -- -- 3.75
300 : 5 -- 2.5 5.0
400 : 5 2.5 3.75 7.5
CTSB0508 50 80 78 114 145 32 32 32 33 500 : 5 2.5 5.0 10.0 0.9
600 : 5 2.5 5.0 15.0
750 : 5 3.75 7.5 15.0
1000 : 5 5.0 10.0 20.0
600 : 5 -- 2.5 3.75
750 : 5 2.5 3.75 7.5
1000 : 5 5.0 7.5 10.0
1250 : 5 5.0 7.5 12.5
CTSB0512 55 125 108 143 191 44 36 49 30 2.2
1500 : 5 7.5 10.0 15.0
2000 : 5 10.0 10.0 20.0
2500 : 5 15.0 20.0 25.0
3000 : 5 15.0 20.0 30.0
500 : 5 2.5 5.0 10.0
600 : 5 2.5 5.0 15.0
750 : 5 3.75 7.5 15.0
CTSB0812 80 120 108 144 185 32 32 32 33 1.25
1000 : 5 5.0 10.0 20.0
1250 : 5 7.5 12.5 20.0
1500 : 5 7.5 15.0 25.0
500 : 5 2.5 5.0 10.0
600 : 5 3.75 5.0 15.0
750 : 5 5.0 10.0 15.0
1000 : 5 10.0 15.0 20.0
1250 : 5 12.5 15.0 25.0
CTSB0816 80 160 120 176 247 48 48 52 38 1500 : 5 15.0 20.0 25.0 4.4
2000 : 5 15.0 20.0 30.0
2500 : 5 15.0 20.0 30.0
3000 : 5 20.0 25.0 30.0
4000 : 5 20.0 25.0 30.0
5000 : 5 20.0 30.0 40.0
45
BH-0.66 Series Ⅰ Current Transformers
Feature
Rectangular shape with stepped window to fit bus bar as well
as single or multi-cables.Main applications are metering and
instrumentation.
Full complete ratio range with six sizes for more application
choices.With its enhanced burden feature,30*30I's rated
burden is able to reach 5 to 10VA with the primary current
lower than 100A,when the turns of the cable going through the
core are 20 to 3.
Order Information
BH 0.66 Ⅰ
0.66 Insulation Level(kV)
30
40
60 Size
80
100
Dimension
30Ⅰ 60 78 34 31 11 12 23 32 58 40 57 ABCE
H
e
46
BH-0.66 Series Ⅰ Current Transformers
Technical Parameters
15 5 2.5(5) 2.5(5)
20 5 2.5(4) 2.5(4)
25 5 2.5(3) 2.5(3)
30 5 2.5(3) 2.5(3)
40 5 2.5(2) 2.5(2)
50 5 2.5(2) 2.5(2)
60 5 2.5(2) 2.5(2)
75 5 2.5 2.5
200 5 5 5
250 5 5 5
300 5 5 5 5 5
400 5 5 5 5 5
500 5 10 5 10 10
600 5 10 5 10 5 10 5 10
750 (800) 5 10 5 10 5 10 5 10
1000 5 15 20 15 20 10 20
1200 (1250) 5 20 20 20
1500 5 20 20 20
2000 5 20 20 20
2500 5 30 30
3000 5 30
Ordering Instruction
1.Please specify the model name,transformation ratio,accuracy class,rated burden,and required installation method,when placing a purchase
order.
2.If there is any special requirements,please contact us,so we can custom make upon request.