MANUFACTURING
Honeywell Hobbs’ commitment to the customer in
past years and present is what has helped us develop
our world-class manufacturing systems. Some of the
methods by which we continuously improve our
products and processes are as follows:
• Kanban cards are used to pull raw material and piece parts
through the factory.
QUALITY SYSTEMS
It is the goal of Honeywell Hobbs to meet customer value-needs through continuously improved products and processes. That is the
basis by which we work to create a partnership with our customers. Evidence of our commitment is proven by a goal of a Shipped
Product Quality Level (SPQL) of 100 ppm. We utilize Advanced Quality Planning and QS9000 based quality systems.
© 2003 Honeywell International Inc. All Rights Reserved.
INTERNET: www.honeywell.com/hobbs
E-mail:
honeywellhobbs.marketing@honeywell.com
Contents:
Angle bracket. For two-screw flange Warranty Periods:
• LCD P. 3-5 AC and DC rectangular meters only, The products listed are warranted
when panel mounting is not practical. for the periods shown:
• D.C. P. 6-7
Part Number 23944.
• A.C. P. 8-11 98000 Series..................2 years
www.honeywell.com/hobbs • Accessories P. 11 85000 Series..................2 years
• Warranty P. 11 20000 Series..................2 years
11
2
28100 Series AC Multi-Range Meters 98000 Series LCD Hour Meters
Unlike conventional AC hour meters that are
limited to one primary voltage andfrequency, the
Hobbs Multi-Range Quartz hour meter will The Hobbs 98000 Series LCD hour
operate over a full range of voltages and
meters provide a large easy-to-read
frequencies. The meters will work accurately
display in a conventional size
over a voltage range of 90 VAC to 264 VAC
and at frequencies of either 50 Hz or 60 Hz.
package. The hour meters are
This unique feature means that one hour meter available in a variety of mounting
will work for virtually any application anywhere styles and voltage ranges that will fit
in the world! Retainer Mount virtually any application.
Operating
Specifications Part #
Voltage Specifications:
• Operating Voltage: 90 to 264 VAC • Run Accuracy ±200ppm; ±0.02%
90-264 VAC 28100 Retainer Mount:
• Frequencies: 50 to 60 Hz • Start Time: maximum 1second
Panel cutout 1.45 x .95
• Temperature Range: -40˚F to +185˚F rectangular opening. • 6 Digit Display 2 Screw Standard Bezel
Two .150 holes spaced 1.750*
Features • Digit Height: 6mm 2 Screw Standard:
• Power draw: .8 mA at 12 VDC Operating
• Records time 0 to 99,999.9 hours Panel cutout 1.45 x .95
(Power Terminal) Voltage Terminals Part # rectangular opening
• Accuracy ±0.02%
Two .150 holes
• UL Recognized • Termination: 1/4” blade 9 to 64 VDC 2 terminal 98310 spaced 1.750*
• CSA (UL) 3/16” blade optional
• Temperature Range: 3 terminal
• CE Mark 9 to 64 VDC with enable 98320
• Totally sealed from dirt and moisture 2 Screw Operating: -40˚C to +85˚C
• Termination Standard Bezel • Vibration: 20 g’s per SAE J1378 9 to 64 VDC
4 terminal
98300
resettable
- 1/4” spade • Shock: 55 g’s per SAE J1378
Operating Part # • Operating ranges:
Benefits Voltage 4.5 to 16 VDC (optional)
• Reduced parts count 90 to 264 VAC 28101 2 Screw Standard: 9 to 64 VDC
• Reduced inventories Panel cutout 1.45 x .95
>64 VDC Contact Factory
• Fewer purchase orders rectangular opening.
Two .150 holes spaced 1.750* • Display:
• Eliminate production line errors 0 to 99,999.9 Hours
• Reduce service parts 0 to 999,999 Counter
Options • Transient Voltage Protection
• Wire leads Load Dump
• Custom lens Inductive
• Terminals (up, down, straight) EMI
Reverse Polarity
WARNING!
Applied voltage not to exceed 264 Vac RMS. This meter 2 Screw Deluxe Bezel
was not intended to be used in applications where
excessive transient voltages are present. It is the Operating
responsibility of the customer to determine the suitability Voltage Part # 2 Screw Deluxe Bezel
of this device for use in their system. Features 2 Screw Deluxe:
90 - 264 VAC 28103 Operating
2 Screw Deluxe:
• Totally sealed from moisture Panel cutout 1.45 x .95
* Panel cutout dimensions are ± .010 tolerance Panel cutout 1.45 x .95 and dirt Voltage Terminals Part # rectangular opening
All dimensions shown in inches and (metric) Two .150 holes
rectangular opening. • Direct replacement for
Two .150 holes spaced 1.750* 9 to 64 VDC 2 terminal 98313 spaced 1.750*
current hour meter
• No battery backup needed 3 terminal
9 to 64 VDC with enable 98323
• Fits in existing panel openings
• Custom bezels and 4 terminal
9 to 64 VDC resettable 98303
dial artwork available
• Snap-in retainer mount
combines easy installation with
rugged design
• Compact Depth
• Rugged Design
• Pulse Counter Option
• Reset Option
Round Black Bezel 3 Screw • Run Indicator
Operating Operating
Voltage Part # Part #
Voltage
90 - 264 VAC 28104 90 - 264 VAC 28105 * Panel cutout dimensions are ± .010 tolerance
Flush Mount (Retainer) 2.24”: 3 Screw Mount: All dimensions shown in inches and (metric)
Panel cutout 2.00 Panel cutout 2.00 diameter opening
diameter opening* Three .125 holes equally
10 3
spaced on 2.42 bolt circle diameter*
98000 Series LCD Hour Meters 20000 Series Deluxe AC Hour Meters
3 terminal
9 to 64 VDC with enable 98322 CAUTION: Always make sure power is removed from equipment before working on
Flush Mount (Retainer) 2.27”: electrical circuits! Only qualified personnel should make electrical connections.
4 terminal Panel cutout 2.00 Damage to equipment and/or serious bodily injury can result from improperly made
9 to 64 VDC resettable 98302 diameter opening* electrical connections, or a failure to adhere to normal electrical safety guidelines.
4 9
20000 Series Deluxe AC Hour Meters LCD Hour Meter Module
When there’s a need to keep track of run
time, quality-minded companies choose The Hobbs LCD hour meter module is a
Hobbs! Whether it’s for testing purposes, custom engineered elapsed time meter
leasing applications, maintenance reasons, designed to be mounted directly to your
and/or warranty programs, you want an printed circuit board (PCB). It can be used
accurate and reliable hour meter. The in a variety of AC or DC applications that
Hobbs 20000 Series hour meter delivers! Rectangular 2 Screw require an hour meter, counter or odometer
for preventive maintenance, warranty
To ensure our high standards of quality, all Operating verification, renting and leasing.
parts are in-process inspected. Every meter Voltage Hertz Termination Part #
must pass 100% function and timing 108 to 132 VAC 50 Screw * 20028 Specifications
accuracy tests before shipping. These 108 to 132 VAC 50 7” Leads ** 20034 • 6 digit/6mm display
“Deluxe” AC meters are also totally sealed 108 to 132 VAC 60 Screw * 20001 • ±0.02% Accuracy
and 108 to 132 VAC 60 7” Leads ** 20035 • Vibration tested per MIL-M-3971D at
benefit from an uncommon design which 216 to 264 VAC 50 Screw * 20029 10 g’s and SAE J1378 at 20 g’s
integrates the motor and frame into one 216 to 264 VAC 50 7” Leads ** 20036 • Shock tested per MIL-M-3971D at 75 g’s
substructure. 216 to 264 VAC 60 Screw * 20007 and SAE J1378 at 55 g’s
216 to 264 VAC 60 7” Leads ** 20037 • Operating temp. range -40˚C to +85˚C
Two-Screw Mount: Panel cut out
Specifications 1.45 x .95 rectangular • Operating voltage range 9 to 64 VDC
• Records up to 99,999 hours opening. Two .150 holes (optional 4.5 to 16 VDC)
Automatic recycle to zero spaced 1.750.* • Transient Voltage Protected
• 24,120 and 240 VAC models available Over Voltage
(Range ±10%) Load Dump D.C. Version
• 50 and 60 Hertz versions Inductive
• 3.0 watts power rating EMI Operating
• Operating temperature: - 65°F to +154°F Reverse Polarity Voltage Termination Part #
(-54°C to +68°C) • Power Consumption 9 to 64 VDC
4 pin 98706
• Accuracy: ±.02%. .8 ma max at 12V (power terminal) with enable & reset
• Weight: 3 oz • Start time: maximum 1 second
4.5 to 16 VDC 4 pin 98707
• Screw termination or 7” lead wires LCD Module
• Lens material: All Hobbs modules have crucial APPLICATIONS
3-screw mount: Glass components exposed. The module
All others: Polycarbonate must be sufficiently protected if Counter Version • Medical
• Case material: Polycarbonate Round 3 Screw used in an environment other than
• Vending Machines
• Number size: 0.12” (3mm) specified. Consult Hobbs Operating
Operating • Floor Cleaning Equip.
• UL Listed (File # E47098): Screw terminals marketing department when Voltage Termination Part #
Voltage Hertz Termination Part # • Electronic Panels
• UL Recognized: Wire lead versions suitability of application is 9 to 64 VDC
• Instrument Panels
108 to 132 VAC 50 Screw * 20016 4 terminal 98704
• CSA Certified (File # LR42455) questioned. with reset
• Recreational
108 to 132 VAC 50 7” Leads ** 20042
• Conforms to MIL-M-3971 * 9 to 64 VDC
• Office Equipment
108 to 132 VAC 60 Screw * 20017 Three-Screw Mount: Panel cut out
3 terminal 98705
• CE Mark without reset
108 to 132 VAC 60 7” Leads ** 20043 2.00 diameter opening. Three
216 to 264 VAC 50 Screw * 20018 .125 holes equaly spaced on Features
Features 2.42 bolt circle diameter.* Options
• Polycarbonate, shock resistant, tamper 216 to 264 VAC 50 7” Leads ** 20044 • Large easy-to-read numbers
4.5 to 16 VDC
proof case 216 to 264 VAC 60 Screw * 20019 • Silent operation
• Totally sealed * 216 to 264 VAC 60 7” Leads ** 20045 • Low power demand
* Panel cutout dimensions are ± .010 tolerance
• Single phase, synchronous, permanently • Resettable and nonresettable All dimensions shown in inches and (metric)
* UL Listed, CSA Certified and CE Mark
lubricated motor ** UL Recognized, CSA Certified and CE Mark
• 10 years data retention (without power)
• Custom logo dials, 1/4” blade terminals, over entire temperature range
special wire lengths. AC • UL Recognized, CSA approved
APPLICATIONS • Pin termination .03 in diameter
• Hours from 0 to 99,999.9
• Business machines • Air conditioning
Options: If you need it, let us know. • Counter from 0 to 999,999 pulses
• Control panels • Furnaces
YOUR satisfaction is our goal! • Voltages greater than 64 VDC
• Lighting systems • Lab test equipment
contact factory
• Generators • Sun tanning equipment
• Compressors & pumps • Oxygen concentrators
* Applicable on shown “screw terminal” • Refrigeration • Many more!
meters. Contact Hobbs for specifications
on other available models. * Panel cutout dimensions are ± .010 tolerance
All dimensions shown in inches and (metric)
8 5
85000 Series Quartz Plus DC Hour Meters 85000 Series Quartz Plus DC Hour Meters
The 85000 Series provides legendary DC
Hobbs performance and reliability in a APPLICATIONS
technically advanced quartz package. Round Chrome Bezel • Lawn Tractors
The Quartz Plus features a highly reliable • Garden Tractors
drive mechanism, an improved odometer Operating Part # Part # Part # Part #
Flush Cup Flush Cup Stirrup Stirrup • Farm Equipment
gear train, and a snap-together integrated Voltage 2.27” 2.50” 2.27” 2.50” • Gen Sets
chassis. The chassis fits into a shockproof, • Construction
10-32 VDC 85002 85006 85004 85008
totally-sealed case made of an engineered Equipment
2 Screw 10-80 VDC 85342 85098
plastic that is impervious to acids and • Utility Vehicles
Operating 30-110 VDC 85015 85019 85017 85021
solvents. Part # • Industrial
Voltage
Equipment
To ensure our high standards of quality, all 6.5-16 VDC 85331
• Recreational
10-32 VDC 85000
parts are in-process inspected. Every Round Black Bezel Vehicles
Quartz Plus meter must pass 100% function, 10-80 VDC 85094
Two-Screw Mount: Panel cutout Part # Part # Part # Part # • Golf Carts
burn-in, and timing accuracy test before 30-110 VDC 85013
1.45 x.95 rectangular opening. Operating Flush Cup Flush Cup Stirrup Stirrup • Aircraft
shipping. Two .150 holes spaced 1.750. * Voltage 2.27” 2.50” 2.27” 2.50” • Medical Equipment
• Office Equipment
10-32 VDC 85003 85007 85005 85009
Specifications • Any application
10-80 VDC 85093 85099
• 10,000 hour version standard, requiring a very
30-110 VDC 85016 85020 85018 85022
with automatic recycle to zero accurate and
• Temperature range: - 40° F to +185° F dependable hour
- 40° C to +85° C meter.
• Quartz accuracy: ±200ppm, ±0.02%
(entire voltage and temperature range)
• Operating voltage range: 5-110 VDC
(Voltage range covered by 85000 Series line) 3 Screw
• Precision built relay driven odometer Operating
• Excellent vibration & shock resistance: Voltage Part #
Vibration: 20 g’s @ 10-80Hz (SAE J1378) Three-Screw Mount: Panel cutout
10-32 VDC 85001
10 g’s (per MIL-M-3971) 2.00 diameter opening. Three .150
10-80 VDC 85097 holes equally spaced on 2.53 bolt
Shock: 55 g’s @ 9-13msec (SAE J1378)
30-110 VDC 85014 circle diameter.*
75 g’s (per MIL-M-3971)
• Transient Voltage Protection
Alternator load dump: 150V
EMI (Electromagnetic Interference): +400V @ 500Hz
Inductive switching and reverse polarity
• Standard terminals: 1/4” male blade
• Lens material: Glass
• Case material: Polyester Flush Mount (Cup) Flush Mount (Cup) Flush Mount (Stirrup) Flush Mount (Stirrup)
• Number size: 0.12” (3mm) Rectangular Stirrup 2.27”: Panel cutout 2.5”: Panel cutout 2.27”: Panel cutout 2.5”: Panel cutout
Operating 2.00 diameter opening.* 2.00 diameter opening.* 2.00 diameter opening.* 2.00 diameter opening.*
Voltage Part #
* Panel cutout dimensions are ± .010 tolerance
Features 10-32 VDC 85010 All dimensions shown in inches and (metric)
• Custom CMOS integrated circuit 30-110 VDC 85023 85000 Series Wiring Diagrams (Polarity Sensitive)
• Indicates operating time in hours Rectangular Stirrup: Panel cutout
1.45 x .95 rectangular opening.* + +
and tenths, plus has a running indicator
• Totally-sealed
• Battery system voltages:
6,12,24,36,48,60,72,and 80 VDC
• UL Recognized (File number AU1774)
• CSA Certified (File number LR42455-12)
• Conforms to MIL-M-3971 Retainer Mount
CAUTION: Always make sure power is removed from equipment before working on
Operating
Options:
Voltage Part # electrical circuits! Only qualified personnel should make electrical connections.
Damage to equipment and/or serious bodily injury can result from improperly made
Custom logos, polycarbonate lenses, and
10-32 VDC 82001 electrical connections, or a failure to adhere to normal electrical safety guidelines
various bezels. Wire, stud, blade, and
10-80 VDC 82320
screw terminals. 100,000 hour, R-Terminal
and filtered versions available too. * Panel cutout dimensions are ± .010 tolerance
All dimensions shown in inches and (metric) Retainer Mount: Panel cutout
6 7
1.45 x .95 rectangular opening.*