You are on page 1of 107

PM NO.

0148E
RAS-20CNHZ2
RAM-50CNHZ2
SERVICE MANUAL RAS-30CNHZ2
TECHNICAL INFORMATION
REFER TO THE FOUNDATION MANUAL
FOR SERVICE PERSONNEL ONLY
CONTENTS

SPECIFICATIONS ------------------------------------------------------------------- 7

HOW TO USE ---------------------------------------------------------------------- 10

CONSTRUCTION AND DIMENSIONAL DIAGRAM --------------------- 35

MAIN PARTS COMPONENT -------------------------------------------------- 37


RAS-20CNHZ2 RAS-30CNHZ2 WIRING DIAGRAM ---------------------------------------------------------------- 39

CIRCUIT DIAGRAM --------------------------------------------------------------- 41

PRINTED WIRING BOARD LOCATION DIAGRAM --------------------- 43

BLOCK DIAGRAM ----------------------------------------------------------------- 49

BASIC MODE ----------------------------------------------------------------------- 51

REFRIGERATING CYCLE DIAGRAM --------------------------------------- 64

DESCRIPTION OF MAIN CIRCUIT OPERATION (INDOOR) -------- 65

DESCRIPTION OF MAIN CIRCUIT OPERATION (OUTDOOR) ---- 71

TROUBLE SHOOTING ----------------------------------------------------------- 95


RAM-50CNHZ2
PARTS LIST AND DIAGRAM ------------------------------------------------- 110

SPECIFICATIONS
DC INVERTER DUAL SYSTEM MULTI (WALL TYPE)
TYPE
INDOOR UNIT OUTDOOR UNIT
MODEL RAS-20CNHZ2 RAS-30CNHZ2 RAM-50CNHZ2
POWER SOURCE 1ø, 220V – 230V, 50Hz
TOTAL INPUT (W)
TOTAL AMPERES (A)
REFER TO THE SPECIFICATIONS PAGE 8.
COOLING CAPACITY (kW)
HEATING CAPACITY (B.T.U.)
W 745 798 850
DIMENSIONS (mm) H 248 265 650
D 175 168 298
NET WEIGHT (kg) 5.5 6.5 43

SPECIFICATIONS AND PARTS ARE SUBJECT TO CHANGE FOR IMPROVEMENT

ROOM AIR CONDITIONER


INDOOR UNIT + OUTDOOR UNIT

MAY 2002 H.A.P.M.


SAFETY DURING REPAIR WORK

1. In order to disassemble and repair


the unit in question, be sure to
ct
disconnect the power cord plug
c o nne
is
from the power outlet before starting
m u st d plug
the work. t, I ord let.
Firs ower c er out
p w
the the po
from

2. If it is necessary to replace any parts, they should be replaced with respective genuine parts for the unit, and
the replacement must be effected in correct manner according to the instructions in the Service Manual of
the unit.

If the contacts of electrical parts


are defective, replace the
electrical parts without trying to
repair them.

3. After completion of repairs, the initial state


should be restored.

4. Lead wires should be connected and laid as


in the initial state.

5. Modification of the unit by user himself should


absolutely be prohibited.

6. Tools and measuring instruments for use in repairs or inspection should be accurately calibrated in advance.

7. In installing the unit having been repaired, be careful to prevent the occurence of any accident such as
electrical shock, leak of current, or bodily injury due to the drop of any part.

8. To check the insulation of the unit, measure the insulation resistance between the power cord plug and
grounding terminal of the unit. The insulation resistance should be 1M or more as measured by a 500V
DC megger.

9. The initial location of installation such as window, floor or the other should be checked for being and safe
enough to support the repaired unit again.
If it is found not so strong and safe, the unit should be installed at the initial location reinforced or at a new
location.

10. Any inflammable thing should never


be placed about the location of
installation. DANGER

11. Check the grounding to see whether


it is proper or not, and if it is found
improper, connect the grounding
terminal to the earth.

– 1 –
WORKING STANDARDS FOR PREVENTING BREAKAGE OF SEMICONDUCTORS

1. Scope
The standards provide for items to be generally observed in carrying and handling semiconductors in relative
manufacturers during maintenance and handling thereof. (They apply the same to handling of abnormal goods
such as rejected goods being returned).

2. Object parts

(1) Micro computer


(2) Integrated circuits (IC)
(3) Field-effect transistors (FET)
(4) P.C. boards or the like on which the parts mentioned in (1) and (2) of this paragraph are equipped.

3. Items to be observed in handling

(1) Use a conductive container for carrying and storing of parts. (Even rejected goods should be handled in
the same way).

A conductive polyvinyl bag IC

Conductive sponge
IC

Fig. 1. Conductive Container

(2) When any part is handled uncovered (in counting, packing and the like), the handling person must always
use himself as a body earth. (Make yourself a body earth by passing one M ohm earth resistance through
a ring or bracelet).

(3) Be careful not to touch the parts with your clothing when you hold a part even if a body earth is being
taken.

(4) Be sure to place a part on a metal plate with grounding.

(5) Be careful not to fail to turn off power when you repair the printed circuit board. At the same time, try
to repair the printed circuit board on a grounded metal plate.

Body earth
(Elimik conductive band)

Clip for connection with a


1M grounding wire

Fig. 2. Body Earth

– 2 –
(6) Use a three wire type soldering iron including a grounding wire.

Metal plate (of aluminium, stainless steel, etc.)

Working
table

Resistor of 1 M (1/2W)

Staple
Earth wire

Bare copper wire (for body earth)

Fig. 3. Grounding of the working table

Soldering iron

2 Grounding
wire

Screw stop at the screwed


part using a rag plate

Fig. 4. Grounding a soldering iron

Use a high insulation mode (100V, 10M or higher) when ordinary iron is to be used.

(7) In checking circuits for maintenance, inspection or some others, be careful not to have the test probes of the
measuring instrument shortcircuit a load circuit or the like.

– 3 –
CAUTION

1. In quiet operation or stopping the operation, slight flowing noise of refrigerant in the refrigerating cycle is
heard occasionally, but this noise is not abnormal for the operation.

2. When it thunders near by, it is recommend to stop the operation and to disconnect the power cord plug from
the power outlet for safety.

3. The room air conditioner does not start automatically after recovery of the electric power failure for preventing
fuse blowing. Re-press START/STOP button after 3 minutes from when unit stopped.

4. If the room air conditioner is stopped by adjusting setting temperature, or missoperation, and re-start in a
moment, there is occasion that the cooling and heating operation does not start for 3 minutes, it is not
abnormal and this is the result of the operation of IC delay circuit. This IC delay circuit ensures that there
is no danger of blowing fuse or damaging parts even if operation is restarted accidentally.

5. This room air conditioner should not be used at the cooling operation when the outside temperature is below
10°C (50°F).

6. This room air conditioner (the reverse cycle) should not be used when the outside temperature is below
-10°C (14°F).
If the reverse cycle is used under this condition, the outside heat exchanger is frosted and efficiency falls.

7. When the outside heat exchanger is frosted, the frost is melted by operating the hot gas system, it is not
trouble that at this time fan stops and the vapour may rise from the outside heat exchanger.

– 4 –
SAFETY PRECAUTION
● Please read the “Safety Precaution” carefully before operating the unit to ensure correct usage of the unit.
● Pay special attention to signs of “ Warning” and “ Caution”. The “Warning” section contains matters which,
if not observed strictly, may cause death or serious injury. The “Caution” section contains matters which may
result in serious consequences if not observed properly. Please observe all instructions strictly to ensure safety.
● The sign indicate the following meanings.

Make sure to connect earth line. The sign in the figure indicates prohibition.

Indicates the instructions that must be followed.

● Please keep this manual after reading.

PRECAUTIONS DURING INSTALLATION


● Do not reconstruct the unit.
Water leakage, fault, short circuit or fire may occur if you reconstruct
the unit by yourself.
● Please ask your sales agent or qualified technician for the installation
of your unit. Water leakage, short circuit or fire may occur if you install
WARNING the unit by yourself.
● Please use earth line.
Do not place the earth line near water or gas pipes, lightning-conductor,
or the earth line of telephone. Improper installation of earth line may
cause electric shock.
● A circuit breaker should be installed depending on the mounting site of
the unit. Without a circuit breaker, the danger of electric shock exists.
● Do not install near location where there is flammable gas. The outdoor
CAUTION unit may catch fire if flammable gas leaks around it.
● Please ensure smooth flow of water when installing the drain hose.

PRECAUTIONS DURING SHIFTING OR MAINTENANCE


● Should abnormal situation arises (like burning smell), please stop operating the unit
and turn off the circuit breaker. Contact your agent. Fault, short circuit or fire may
W occur if you continue to operate the unit under abnormal situation.
A
R ● Please contact your agent for maintenance. Improper self maintenance may cause
N electric shock and fire.
I
N ● Please contact your agent if you need to remove and reinstall the unit. Electric
G shock or fire may occur if you remove and reinstall the unit yourself improperly.

PRECAUTIONS DURING OPERATION


● Avoid an extended period of direct air flow for your health.

W ● Do not put objects like thin rods into the panel of blower and suction side
A because the high-speed fan inside may cause danger.
R
N
● Do not use any conductor as fuse wire, this could cause fatal accident.
I
N
G ● During thunder storm, disconnect and turn off the circuit breaker.

– 5 –
PRECAUTIONS DURING OPERATION

● The product shall be operated under the manufacturer specification and


not for any other intended use.

● Do not attempt to operate the unit with wet hands, this could cause fatal
accident.

● When operating the unit with burning equipments, regularly ventilate the
room to avoid oxygen insufficiency.

● Do not direct the cool air coming out from the air-conditioner panel to face
household heating apparatus as this may affect the working of apparatus
such as the electric kettle, oven etc.

● Please ensure that outdoor mounting frame is always stable, firm and
without defect. If not, the outdoor unit may collapse and cause danger.

● Do not splash or direct water to the body of the unit when cleaning it as this
may cause short circuit.

C
● Do not place plants directly under the air flow as it is bad for the plants.
A
U
T
I
O ● Please switch off the unit and turn off the circuit breaker during cleaning, the
N high-speed fan inside the unit may cause danger.

● Turn off the circuit breaker if the unit is not to be operated for a long period.

● Do not climb on the outdoor unit or put objects on it.

● Do not put water container (like vase) on the indoor unit to avoid water
dripping into the unit. Dripping water will damage the insulator inside the unit
and causes short-circuit.

● When operating the unit with the door and windows opened, (the room humidity is always above
80%) and with the air deflector facing down or moving automatically for a long period of time,
water will condense on the air deflector and drips down occasionally. This will wet your furniture.
Therefore, do not operate under such condition for a long time.
● If the amount of heat in the room is above the cooling or heating capability of the unit (for
example: more people entering the room, using heating equipments and etc.), the preset room
temperature cannot be achieved.

– 6 –
SPECIFICATIONS
RAS-20CNHZ2/
MODEL RAM-50CNHZ2
RAS-30CNHZ2

FAN MOTOR 20 W 40 W

FAN MOTOR CAPACITOR NO NO

FAN MOTOR PROTECTOR NO NO

COMPRESSOR — GW20DN8A

COMPRESSOR MOTOR CAPACITOR NO NO

OVERLOAD PROTECTOR NO YES

OVERHEAT PROTECTOR NO YES

FUSE (MICRO COMPUTER CIRCUIT) NO 3.0A

FUSE (MAIN SUPPLY) NO 25A

FUSE (FAN MOTOR) NO 2A

POWER RELAY NO G4A

POWER SWITCH NO NO

TEMPORARY SWITCH YES NO

SERVICE SWITCH NO YES

TRANSFORMER NO NO

VARISTOR NO 450NR

NOISE SUPPRESSOR NO 20132A

THERMOSTAT YES(IC) YES(IC)

REMOTE CONTROL SWITCH (LIQUID CRYSTAL) YES NO

FUSE CAPACITY 16 A TIME DELAY FUSE

UNIT ---------- ❈ 1350g


REFRIGERANT CHARGING
VOLUME
(Refrigerant 22) WITHOUT REFRIGERANT BECAUSE
PIPES (MAX. 35m) COUPLING IS FLARE TYPE.

– 7 –
SPECIFICATIONS FOR INDOOR UNITS COMBINATIONS

WALL TYPE DC INVERTER QUADRUPLE SYSTEM MULTI


TYPE
COOLING AND HEATING
INDOOR UNIT RAS-20CNHZ2 RAS-30CNHZ2
MODEL
OUTDOOR UNIT RAM-50CNHZ2
PHASE/VOLTAGE/FREQUENCY 1ø, 220V-230V, 50Hz
CIRCUIT AMPERES TO CONNECT (A) 16

CAPACITY (kW) 2.50 (1.00~3.00) 3.20 (1.00~3.30)


(B.T.U./h)
8530 (3412~10236) 10919 (3412~11260)
TOTAL INPUT (W) 1000 (300~1080) 1100 (300~1160)
COOLING
EER (B.T.U./hW) 8.53 9.93
(ONE UNIT)
TOTAL AMPERES (A) 4.50 5.00
POWER FACTOR (%) 97 96
SOUND LEVEL (INDOOR) 33 35
AIR FLOW VOLUME (Hi) 5.7m3/min 8.5m3/min

CAPACITY (kW) 5.40 (1.00~5.60)


(B.T.U./h) 18426 (3412~19108)
COOLING TOTAL INPUT (W) 2150 (450~2200)
(TWO EER (B.T.U./hW) 8.57
UNITS) TOTAL AMPERES (A) 9.40
POWER FACTOR (%) 99
SOUND LEVEL (OUTDOOR) 50

CAPACITY (kW) 3.60 (0.90~4.00) 4.50 (0.90~4.60)


(B.T.U./h) 12284 (3071~13649) 15355 (3071~15696)
TOTAL INPUT (W) 1470 (120~1690) 1900 (120~1920)
HEATING
EER (B.T.U./hW) 8.36 8.08
(ONE UNIT)
TOTAL AMPERES (A) 6.50 8.30
POWER FACTOR (%) 98 99
SOUND LEVEL (INDOOR) 33 37
AIR FLOW VOLUME (Hi) 7.7m3/min 9.5m3/min

CAPACITY (kW) 6.40 (1.50~7.00)


(B.T.U./h) 21838 (5118~23885)
HEATING TOTAL INPUT (W) 2100 (450~2300)
(TWO EER (B.T.U./hW) 9.66
UNITS) TOTAL AMPERES (A) 9.20
POWER FACTOR (%) 99
SOUND LEVEL (OUTDOOR) 52
AIR DEFLECTORS YES (AUTO SWING) YES (AUTO SWING)
FAN SPEED 3 3
NOT PROVIDED (POWER CORD SHOULD BE PREPARED AND
LINE CORD
CONNECTED TO OUTDOOR UNIT WHEN INSTALLED)
REMOTE CONTROL SWITCH YES (WIRELESS) YES (WIRELESS)
MAXIMUM LENGTH OF PIPING MAX. 35m (TWO UNITS TOTAL)
STANDARD CE (EMC&LVD)

MODEL RAS-20CNHZ2 RAS-30CNHZ2 RAM-50CNHZ2


W 792 850 1008
PACKING H 302 340 698
(mm)
D 255 270 394
cu.ft. 2.15 2.76 9.79
GROSSWEIGHT (kg) 9.5 10 48
FLARENUTSIZE (SMALL/LARGE) — — 6.35D/9.52D, 6.35D/9.52D

– 8 –
INSTALLATION
HEIGHT DIFFERENCE
Height difference between indoor units should not be more than 5m.

Indoor unit 1

Maximum 5 m Indoor unit 2

Outdoor unit (Within ±10 m)

PIPING LENGTH

Indoor unit 2 Indoor unit 1

L2 L1
Outdoor unit

(L1 + L2) = Maximum 35m


Maximum piping length for one indoor unit is 25m.
Additional R-22
2.5+2.5 0g
2.5+3.2 0g
TWO
UNITS ~20m add 0g
~25m add 25g
3.2+3.2
~30m add 50g
~35m add 75g

– 9 –
MULTI-AIR CONDITIONER
With this multi-air conditioner, 2 indoor units can be connected to one outdoor unit to be driven. You can operate the
required number of indoor units.

Combination of Operations:
● You cannot operate the indoor units in the ● The indoor unit which is switched on first continues to operate,
following combination. but other indoor units which is switched on later does not
operate while the lamp lights.
One unit Other unit
● To re-start an indoor unit which was operated later, stop the
Heating Cooling indoor unit which was operated first or later and reset the type
of operation, then perform operation again.
Heating Dehumidifying

Heating Circulating (fan)

Adjusting the Number of Indoor Units:


The more the indoor units to be operated, the lower the power of each unit. Refer to the
specification on installation manual. Decrease the number of indoor units to be operated
especially when it is very hot or cold or when you want to reach the present temperature
quickly.

Stopped Indoor Units:


When an indoor unit is operated in the cooling, heating or dehumidifying mode in the room, the sound of refrigerant flow
may be heard from a stopped indoor unit or a stopped indoor unit may become warm. This is because the indoor unit
returns refrigerant to the outdoor unit to be ready for operation.

Outdoor Units:
● Even after operation is stopped, the fan of the outdoor unit continues to rotate for 10-60 seconds to cool the internal
electrical parts.
● During heating, condensed water flows out from the outdoor unit and the defrosting water flows out during defrosting.
Do not block the drain outlet of the outdoor unit in a cold place; otherwise the condensed or defrosting water could
freeze.

NAMES AND FUNCTIONS OF EACH PART

OUTDOOR UNIT
DRAIN PIPE
Condensed water drain to outside.

CONNECTING CORD

AIR INLET (BACK, LEFT SIDE)

AIR OUTLET

MODEL NAME AND DIMENSIONS

MODEL WIDTH (mm) HEIGHT (mm) DEPTH (mm)

RAS-20CNHZ2 744 248 168


RAS-30CNHZ2 798 265 168
RAM-50CNHZ2 850 650 298

– 10 –
NAMES AND FUNCTIONS OF EACH PART

INDOOR UNIT
RAS-20CNHZ2

AIR FILTER
To prevent dust from coming into the indoor unit.
(Refer page 30)

INDOOR UNIT INDICATORS


Light indicator showing the operating condition.
(Refer page 12)

FRONT PANEL (AIR INLET)

HORIZONTAL DEFLECTOR ● VERTICAL


DEFLECTOR (AIR OUTLET)
(Refer page 24)

REMOTE CONTROLLER
Send out operation signal to the indoor unit. So as to
operate the whole unit.
(Refer page 14)

RAS-30CNHZ2

AIR FILTER
To prevent dust from coming into the indoor unit.
(Refer page 31)

INDOOR UNIT INDICATORS


Light indicator showing the operating condition.
(Refer page 13)

FRONT PANEL (AIR INLET)

HORIZONTAL DEFLECTOR ● VERTICAL


DEFLECTOR (AIR OUTLET)
(Refer page 24)

REMOTE CONTROLLER
Send out operation signal to the indoor unit. So as to
operate the whole unit.
(Refer page 14)

– 11 –
OPERATION INDICATOR
RAS-20CNHZ2
NORMAL TEMPORARY
/AUTO

TEMPORARY SWITCH
Use this switch to start and stop when the remote controller does not work.
● By setting the temporary switch, the operation is done in previously set
operation mode.
● When the operation is done using the temporary switch after the power
source is turned off and turn on again, the operation is done in automatic
mode.

AUTO RESTART SWITCH


● In the event of power failure, the air conditioner will restart automatically
in the previously selected mode once the power is restored.
● In the event of power failure during TIMER operation, the timer will be
reset and the unit will begin or stop operating under a new timer setting.

NORMAL
Use this switch in order to prevent the unit from switch ON after the power
supply resuming from the power failure.

SELECTOR SWITCH IS PRESET AT NORMAL POSITION.

Indoor unit 2 Indoor unit 1


! CAUTION
1. Turn on the circuit breaker first before switching the auto restart switch to Outdoor unit
AUTO. Failure to do so may result the unit to run at previous preset mode or
cannot operate.
2. Operation of indoor units are as mentioned on page 10 “Combination of
Operations. (Priority of operation is for unit no. 2)

INDOOR UNIT INDICATORS


OPERATION LAMP
This lamp lights during operation.
The OPERATION LAMP flashes in the following cases
during heating.
(1) During preheating
For about 2–3 minutes after starting up.
(2) During defrosting
Defrosting will be performed about 50 minutes when
frost forms on the heat exchanger of the outdoor
unit, for 5–10 minutes each time.

TIMER LAMP
This lamp lights when the timer is working.

SIGNAL RECEIVER
There will be a beep sound when this receiver receives
signal from remote controller.

– 12 –
OPERATION INDICATOR
RAS-30CNHZ2

TEMPORARY SWITCH
Use this switch to start and stop when the remote controller does not work.

SELECTOR SWITCH

AUTO RESTART SWITCH


● In the event of power failure, the air conditioner will restart automatically in
AUTO TEMPORARY

the previously selected mode once the power is restored.


NORMAL RESTART
SWITCH

● In the event of power failure during TIMER operation, the timer will be reset
and the unit will begin or stop operating under a new timer setting.

NORMAL
Use this switch in order to prevent the unit from switch ON after the power
supply resuming from the power failure.

SELECTOR SWITCH IS PRESET AT NORMAL POSITION.

Indoor unit 2 Indoor unit 1


! CAUTION
1. Turn on the circuit breaker first before switching the auto restart switch to Outdoor unit
AUTO. Failure to do so may result the unit to run at previous preset mode or
cannot operate.
2. Operation of indoor units are as mentioned on page 10 “Combination of
Operations. (Priority of operation is for unit no. 2)

INDOOR UNIT INDICATORS


OPERATION LAMP
This lamp lights during operation.
The OPERATION LAMP flashes in the following cases
during heating.
(1) During preheating
For about 2–3 minutes after starting up.
(2) During defrosting
Defrosting will be performed about 50 minutes when
frost forms on the heat exchanger of the outdoor unit,
for 5–10 minutes each time.

FILTER LAMP
When the device is operated for a total of about 100 hours,
the FILTER lamp lights to indicate that it is time to clean
the filter. The lamp goes out when the POWER SWITCH
set to OFF and ON again.

SIGNAL RECEIVER
There will be a beep sound when this receiver receives
signal from remote controller.

TIMER LAMP
This lamp lights when the timer is working.

– 13 –
NAMES AND FUNCTIONS OF REMOTE CONTROL UNIT
REMOTE CONTROLLER
This controls the operation of the indoor unit. The range of control is about 7 meters. If indoor lighting
is controlled electronically, the range of control may be shorter.
This unit can be fixed on a wall using the fixture provided. Before fixing it, make sure the indoor unit can
be controlled from the remote controller.

● Signal emitting window/transmission sign


Point this window toward the indoor unit when controlling it.
˚CH The transmission sign blinks when a signal is sent.
● Display
This indicates the room temperature selected, current time, timer status,
function and intensity of circulation selected.
● START/STOP button
Press this button to start operation. Press it again to stop operation.
● SLEEP button
Use this button to set the sleep timer.
● TEMPERATURE buttons
Use these buttons to raise or lower the temperature setting. (Keep pressed,
and the value will change more quickly.)
● TIME button
Use this button to set and check the time and date.
● RESET buttons
● FUNCTION selector
Use this button to select the operating mode. Every time you press it,
˚CH
the mode will change from (AUTO) to (HEAT) to (DEHUMIDIFY) to
(COOL) and to (FAN) cyclically.
● FAN SPEED selector
This determines the fan speed. Every time you press this button, the intensity
of circulation will change from (AUTO) to (HI) to (MED) to (LOW)
(during the (FAN) mode, from HI to MED to LOW).
RESET
● AUTO SWING button
Controls the angle of the horizontal air deflector.
● TIMER control
Use this button to set the timer.
● OFF-TIMER button Select the turn OFF time.
● ON-TIMER button Select the turn ON time.
● RESERVE button Time setting reservation.
AUTO ● CANCEL button Cancel time reservation.
HEAT

DEHUMIDIFY

COOL
Precautions for Use
FAN
● Do not put the remote controller in the following places.
FAN SPEED
LOW
MED ● In direct sunlight.
HI
● In the vicinity of a heater.
SLEEPING
● Handle the remote controller carefully. Do not drop it on the floor,
STOP (CANCEL)
and protect it from water.
START (RESERVE)
● Once the outdoor unit stops, it will not restart for about 3 minutes
START/STOP
(unless you turn the power switch off and on or unplug the power
TIME
cord and plug it in again).
TIMER SET
This is to protect the device and does not indicate a failure.
TIMER SELECTOR
ON TIMER ● If you press the FUNCTION selector button during operation, the
OFF TIMER
device may stop for about 3 minutes for protection.
AUTO SWING

– 14 –
AUTOMATIC OPERATION
The device will automatically determine the mode of operation, HEAT, COOL or DEHUMIDIFY depending on
the initial room temperature. The selected mode of operation will not change when the room temperature
varies.

Press the FUNCTION selector so that the display indicates the (AUTO)
mode of operation.

1 ● When AUTO has been selected, the device will automatically determine
the mode of operation, HEAT, COOL or DEHUMIDIFY depending on
the initial room temperature.

Press the (START/STOP) button.


RESET START Operation starts with a beep.
STOP Press the button again to stop operation.

■ As the settings are stored in memory in the remote controller, you only have
to press the (START/STOP) button next time.

You can raise or lower the temperature setting as necessary by maximum of


3°C.

°C
Press the temperature button and the temperature setting
will change by 1°C each time.

● The preset temperature and the actual room temperature may vary
somewhat depending on conditions.
● The display does not indicate the preset temperature in the AUTO mode.
If you change the setting, the indoor unit will produce a beep.

■ Condition of Automatic Operation

Initial room temperature


Function Temperature setting FAN SPEED
(approx.)
HI at start, MED or LOW
- - -

Over 27°C COOL 27°C after the preset temperature


is reached
Slightly lower than the
23~27°C DEHUMIDIFY LOW
room temperature
HI at start, MED or LOW
Under 23°C HEAT 23°C after the preset temperature
is reached

– 15 –
HEATING OPERATION

● Use the device for heating when the outdoor temperature is under 21°C.
When it is too warm (over 21°C), the heating function may not work in order to protect the device.

Press the FUNCTION selector so that the display indicates


˚C 1 (HEAT).

Set the desired FAN SPEED with the (FAN SPEED) button
(the display indicates the setting).
(AUTO): The fan speed is HI at first and varies to MED
automatically when the preset temperature has
RESET
2 been reached.
(HI) : Economical as the room will become warm
quickly.
But you may feel a chill at the beginning.
(MED) : Quiet.
(LOW) : More quiet.

Set the desired room temperature with the TEMPERATURE


buttons (the display indicates the setting).

3 The range of 18-22°C is recommended as the


room temperature for heating.
˚C If the temperature setting is 20°C, the room
temperature will be controlled at around 20°C.
The temperature setting and the actual room temperature may
vary somewhat depending on conditions.

START Press the (START/STOP) button. Heating operation starts


with a beep. Press the button again to stop operation.
STOP

■ As the settings are stored in memory in the remote controller, you only
have to press the (START/STOP) button next time.

– 16 –
DEHUMIDIFYING OPERATION

Use the device for dehumidifying when the room temperature is over 16°C.
When it is under 15°C, the dehumidifying function will not work.

START Press the (START/STOP) button. Dehumidifying operation


˚C
STOP starts with a beep. Press the button again to stop operation.

Press the FUNCTION selector so that the display indicates


(DEHUMIDIFY).

RESET
1 The FAN SPEED is set at LOW automatically.
The FAN SPEED button does not work.

Set the desired room temperature with the TEMPERATURE


button (the display indicates the setting).

2 The range of 20-26˚C is recommended as the


room temperature for dehumidifying.

■ As the settings are stored in memory in the remote controller, you only
have to press the (START/STOP) button next time.

■ Dehumidifying Function

When the room temperature is higher than the temperature setting: The device will dehumidify the room,
reducing the room temperature to the preset level.
When the room temperature is lower than the temperature setting: Dehumidifying will be performed at
the temperature setting slightly lower than the current room temperature, regardless of the temperature
setting. The function will stop (the indoor unit will stop emitting air) as soon as the room temperature
becomes lower than the setting temperature.

– 17 –
COOLING OPERATION

Use the device for cooling when the outdoor temperature is 22-42°C.
If humidity is very high (over 80°C) indoors, some dew may form on the air outlet grille of the indoor unit.

Press the FUNCTION selector so that the display indicates


˚C 1 (COOL).

Set the desired FAN SPEED with the (FAN SPEED) button
(the display indicates the setting).

(AUTO): The FAN SPEED is HI at first and varies to


RESET
MED automatically when the preset temperature
2 has been reached.
(HI) : Economical as the room will become cool
quickly.
(MED) : Quiet.
(LOW) : More quiet.

Press the (START/STOP) button. Cooling operation starts


START with a beep. Press the button again to stop operation. The
STOP cooling function does not start if the temperature setting is
higher than the current room temperature (even though the
˚C (OPERATION) lamp lights). The cooling function will start as
soon as you set the temperature below the current room
temperature.
Set the desired room temperature with the TEMPERATURE
button (the display indicates the setting).
3 The range of 25-28°C is recommended as the
room temperature for cooling.
If the temperature setting is 27°C, the room
temperature will be controlled at around 27°C.
The temperature setting and the actual room temperature may
vary somewhat depending on conditions.

■ As the settings are stored in memory in the remote controller, you


only have to press the (START/STOP) button next time.

– 18 –
FAN OPERATION

You can use the device simply as an air circulator. Use this function to dry the interior of the indoor
unit at the end of summer.

Press the FUNCTION selector so that the display indicates


1 (FAN).

2 Press the (FAN SPEED) button.*

START Press the (START/STOP) button. Fan operation starts with


RESET
STOP a beep. Press the button again to stop operation.

* Note • In the fan operation mode, only display of FAN SPEED


setting will change by pressing FAN SPEED button; the
actual fan speed cannot be changed directly from HI to
LOW mode.

FAN SPEED (AUTO) ..... When the AUTO fan speed mode is set in the cooling/heating operation:

● The fan speed will automatically change according to the temperature


of discharged air.
For the heating operation ● When the difference of room temperature and setting temperature is
large, fan starts to run at HI speed.
● When the room temperature reaches setting temperature, fan speed
changes to LOW automatically.

● When the difference of room temperature and setting temperature is


large, fan starts to run at HI speed.
For the cooling operation ● After room temperature reaches the preset temperature, the cooling
operation, which changes the fan speed and room temperature to obtain
optimum conditions for natural healthful cooling will be performed.

– 19 –
HOW TO SET THE TIMER

Time, Day, Month 1 Set the current month and


TIME, DAY, After you change the day with the TIMER control
MONTH batteries; button.
(current time,
day, month)
M D M D

OFF TIMER
RESET

ON TIMER
OFF-Timer 1 Press the (OFF-TIMER)
button. The (OFF) mark blinks
RESERVE on the display.
AM
CANCEL Start STOP

You can set the device to turn off


at the present time.

ON-Timer
Stop Start
1 Press the (ON-TIMER)
button the (ON) mark blinks
on the display.
● The device will turn on
at the designated times.

AM

ON/OFF-Timer 1 Press the (ON-OFF) 2 Set the turn-off time 3 Press the (ON-
button so that the (OFF) with the TIMER control TIMER) button so that the
mark blinks. button. (OFF) mark lights and
Start Stop
Press the (RESERVE) the (ON) mark blinks.
button.
● The device will turn on (off) and off PM
(on) at the designated times.
● The switching occurs first at the PM PM
preset time that comes earlier.
● The arrow mark appearing on the
display indicates the sequence of
switching operations. AM

How to Cancel Reservation


Point the signal window of the remote controller toward the indoor unit, and press the (CANCEL)
button.
The (RESERVED) sign goes out with a beep and the (TIMER) lamp turns off on the indoor unit.

NOTE
You can set only one of the OFF-timer,
ON-timer and ON/OFF-timer.

– 20 –
2 Press the 3 Set the current time with the 4 Press the (TIME) button again.
(TIME) button. TIMER control button. The time indication starts lighting
instead of flashing.

● The time indication will disappear


automatically in 10 second.
PM
AM ● To check the current time setting,
PM PM press the (TIME) button twice.

The setting of the current time is


Example: The current time is 1:30 p.m. now complete.

2 Set the turn-off time with the 3 Point the signal window of the remote controller toward the indoor unit, and
TIMER control button. press the (RESERVE) button.
The (OFF) mark starts lighting instead of flashing and the sign (RESERVED)
PM lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.

PM
Example: The device will turn off at 11:00p.m.

The setting of turn-off time is now complete.

2 Set the turn-on time with the 3 Point the signal window of the remote controller toward the indoor unit, and
TIMER control button. press the (RESERVE) button.
The (ON) mark starts lighting instead of flashing and the (RESERVED) sign
lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.

Example:
AM
AM
The device will automatically turn on earlier so that the preset
temperature can be reached at 7:00 a.m.
The setting of the turn-on time is now complete.

4 Set the turn-on time with the 5 Point the signal window of the remote controller toward the indoor unit, and
TIMER control button. press the (RESERVE) button.
The (ON) mark starts lighting instead of flashing and the (RESERVED) sign
lights. A beep occurs and the (TIMER) lamp lights on the indoor unit.
PM
PM Example:
The device will turn off at 10:30 p.m. and then automatically
turn on earlier so that the preset temperature can be reached
at 7:00 a.m.
AM The settings of the turn-on/off times are now complete.
AM

● The timer may be used in three ways: off-timer, on-timer, and ON/OFF (OFF/ON)-timer. Set
the current time at first because it serves as a reference.

● As the time settings are stored in memory in the remote controller, you only have to press
the (RESERVE) button in order to use the same settings next time.

– 21 –
HOW TO SET THE SLEEP TIMER

Set the current time at first if it is not set before (see the pages for setting
the current time). Press the (SLEEP) button, and the display changes
as shown below.

Mode Indication
41 hour 42 hours 4 3 hours 47 hours
H Sleep timer
Sleep timer off 1

Sleep Timer: The device will continue working for the designated
number of hours and then turn off.
SLEEP Point the signal window of the remote controller toward the indoor
unit, and press the SLEEP button.
The timer information will be displayed on the remote controller.
The TIMER lamp lights with a beep from the indoor unit. When the
sleep timer has been set, the display indicates the turn-off time.
Example: If you set 3 hours sleep
time at 11:38 p.m., the turn-off
H time is 2:38 a.m.

Sleep Start The device will be turned off by the sleep


timer timer and turned on by on-timer.

1 Set the ON-timer.


2 Press the (SLEEP) button and set the sleep timer.
AM For heating:
In this case, the device will turn off
H
in 2 hours (at 1:38 a.m.) and turn
on early so that the preset
AM
temperature will be almost reached
at 6:00 next morning.

How to Cancel Reservation


Point the signal window of the remote controller toward the indoor unit, and press the (CANCEL)
button.
The (RESERVED) sign goes out with a beep and the (TIMER) lamp turns off on the indoor unit.

– 22 –
Explanation of the sleep timer

The device will control the FAN SPEED and room temperature automatically
so as to be quiet and good for people’s health.
You can set the sleep timer to turn off after 1, 2, 3 or 7 hours. The FAN
SPEED and room temperature will be controlled as shown below.

Operation with the sleep timer

Function Operation

The room temperature is kept


The room temperature will be
at about 12°C minimum.
controlled 5°C below the
temperature and the FAN
SPEED will be set to LOW 5°C
Heating
setting 30 minutes after the
“ ” setting of the sleep timer.
Sleep timer set
7 hours
2 hours
later
30 minutes later later
1 hour later 3 hours later

The room temperature is kept


The room temperature will be at about 25–28°C.
Cooling controlled 2°C above the
temperature and the FAN 2°C
“ ”
SPEED will be set to LOW
and setting 30 minutes after the 6 hours
setting of the sleep timer. later
dehumidifying Sleep
timer set 2 hours 7 hours later
“ ” later
30 minutes later 3 hours later

Fan
The settings of room temperature and circulation are varied.
“ ”

NOTE
● If date or current time is not set, sleep timer can not be set.
● If you set the sleep timer after the off-, on/off- or off/on-timer has been set, the sleep timer
becomes effective instead of the off-, on/off- or off/on-timer set earlier.
● You can not set other timer during sleep timer operation.
● After sleep timer time is up and when press sleep button again, the sleep timer will be set as
last setting.
● Sleep timer effective only once.

– 23 –
ADJUSTING THE AIR DEFLECTOR

1 Adjustment of the conditioned air in the upward and downward


directions.
The horizontal air deflector is automatically set to the proper
angle suitable for each operation. The deflector can be swung RESET

up and down continuously and also set to the desired angle


using the “ (AUTO SWING)” button.

● If the “ (AUTO SWING)” button is pressed once,


the horizontal air deflector swings up and down. If the
button is pressed again, the deflector stops in its current
position. Several seconds (about 6 seconds) may be
required before the deflector starts to move.

● Use the horizontal air deflector within the adjusting range


shown on the right.

● When the operation is stopped, the horizontal air deflector


moves and stops at the position where the air outlet
closes.

When cooling
dehumidifying

! CAUTION When heating

● In “Cooling” operation, do not keep the horizontal air


deflector swinging for a long time. Some dew may form
on the horizontal air deflector and some dew may fall
from it.

2 Adjustment of the conditioned air to the left and right.

Hold the vertical air deflector as shown in the figure and adjust
the conditioned air to the left and right.

RAS-30CNHZ2 RAS-20CNHZ2

– 24 –
HOW TO EXCHANGE THE BATTERIES IN THE REMOTE CONTROLLER

1 Remove the cover as shown in the figure and take out the
old batteries.
Push and pull to the
direction of arrow

=
2 Install the new batteries.
The direction of the batteries should match the marks in the
case.

! CAUTION
1. Do not use new and old batteries, or different kinds of batteries
together.
2. Take out the batteries when you do not use the remote controller
for 2 or 3 months.

– 25 –
THE IDEAL WAYS OF OPERATION

Suitable Room Temperature Install curtain or blinds

! Warning It is possible to
Freezing temperature reduce heat
is bad for health and a entering the
waste of electric power. room through
windows.

Ventilation Effective Usage Of Timer


At night, please use the “OFF or ON timer
! Caution operation mode”, together with your wake up
Do not close the room for a long period of time in the morning. This will enable you to
time. Occasionally open the door and windows enjoy a comfortable room temperature. Please
to allow the use the timer effectively.
entrance of
fresh air.

Do Not Forget To Clean The Air Filter Please Adjust Suitable Temperature
Dusty air filter will reduce the air volume and For Baby And Children
the cooling efficiency. To prevent from wasting
Please pay attention to the room temperature
electric energy, please clean the filter every 2
and air flow direction when operating the unit
weeks.
for baby, children and old folks who have
difficulty in movement.

– 26 –
FOR USER’S INFORMATION

The Air Conditioner And The Heat Source In The Room

! Caution
If the amount of heat in the room is above the cooling
capability of the air conditioner (for example: more
people entering the room, using heating equipments
and etc.), the preset room temperature cannot be
achieved.

After Power Failure

When the power is resumed after a power failure,


the indoor unit will still remain “OFF”. To operate the
unit, please press the “ON/OFF” button again.
After power
failure
Operate

Not Operating For A Long Time

When the indoor unit is not to be used for a long


period of time, please switch off the power from the
mains. If the power from mains remains “ON”, the
indoor unit still consumes about 8W in the operation
OFF
control circuit even if it is in “OFF” mode.

When Lightning Occurs

! Warning
To protect the whole unit during lightning, please
stop operating the unit and remove the plug from the
socket.

– 27 –
ATTACHING THE AIR CLEANSING AND DEODORIZING FILTERS
RAS-20CNHZ2

! CAUTION
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,
stop operation and switch off the power supply.

1 Open the front panel.


● Pull up the front panel by holding it at both sides
with both hands.

Front panel

2 Remove the filter.


● Push upward to release the claws and pull out the Front cover
filter.
Claws Air filter

Claws (8 places)

3 Attaching the air cleansing and deodorizing filters


to the filter.
● Attach the air cleansing and deodorizing filters to
the frame by gently compress its both sides and
release after insertion into filter frame.
Make sure the “FRONT” is facing back side
CAUTION
Do not bend the air cleansing
and deodorizing filter as it may
cause damage to the structure.

4 Attach the filters.


● Attach the filters by ensuring that the surface written
“FRONT” is facing front.
● After attaching the filters, push the front panel at
three arrow portion as shown in figure and close it.

NOTE
● In case of removing the air cleansing and deodorizing filters, please follow the above procedures.
● The cooling capacity is slightly weakened and the cooling speed becomes slower when the air cleansing
and deodorizing filters are used. So, set the fan speed to "HIGH" when using it in this condition.
● Air cleansing and deodorizing filters are washable and reusable up to 20 times by using vacuum
cleaner or water rinse under running tap water. Type number for this air cleansing filter is <SPX-CFH5>.
Please use this number for ordering when you want to renew it.
● Do not operate the air conditioner without filter. Dust may enter the air conditioner and fault may occur.

– 28 –
ATTACHING THE AIR CLEANSING AND DEODORIZING FILTERS
RAS-30CNHZ2

! CAUTION
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,
stop operation and switch off the power supply.

1 Open the front panel.


● Be sure to hold the button sides on the left and
right of the front panel with both hands and pull
up the front panel forward.

Front panel

2 ● Slightly lift the filter and release the claws (2


locations) at the lower part of the front cover
and remove the filter from the lower side.
Front cover

Claws Air filter

Claws
3 Attaching the air cleansing and deodorizing
filters to the filter. Frame
● Attach the air cleansing and deodorizing filters
Air cleansing
to the frame by gently compress its both sides and
and release after insertion into filter frame. deodorizing
Make sure the filter
“FRONT” is Filter
CAUTION facing back
side.
Do not bend the air cleansing
and deodorizing filter as it may
cause damage to the structure.

4 Attach the filters.


● Attach the filters by ensuring that the surface
written “FRONT” is facing front.
● After attaching the filters, push the front panel
at three arrow portion as shown in figure and
close it.

NOTE:
● The cooling capacity is slightly weakened and the cooling speed becomes slower when the air
cleaning and deodorizing filter is used. So, set the fan speed to “HIGH” when using it in this
condition.
● Air cleansing and deodorizing filters is washable and reusable up to 20 times by using vacuum
cleaner or water rinse. Type number for this air cleaning filter is <SPX-CFH5>. Please use this
number for ordering when you want to renew it.

– 29 –
MAINTENANCE
RAS-20CNHZ2

! CAUTION
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,
stop operation and switch off the power supply.

1. AIR FILTER
Clean the air filter, as it removes dust inside the room. In case the air filter is full of dust, the air flow
will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to clean the
filter following the procedure below.
REMOVING METHOD
PROCEDURE

1 Open the front panel and remove the filter


● Gently lift and remove the air cleansing and
deodorizing filter from the air filter frame.

2 Vacuum dust from the air filter and air cleansing


and deodorizing filter using vacuum cleaner. If
there is too much dust, rinse under running tap
water and gently brush it with soft bristle brush.
Allow filters to dry in shade.
Air cleansing and Air filter
deodorizing filter

INSTALLATION METHOD

3 ● Re-insert the air cleansing and deodorizing


filter to the filter frame. Set the filter with
“FRONT” mark facing front, and slot them into
the original state.
● After attaching the filters, push the front panel
at three arrow portions as shown in figure
and close it.

NOTE:
● Air cleansing and deodorizing filter should be cleaned every month or sooner if noticeable loading
occurs. When used overtime, it may loose its deodorizing function. For maximum performance, it is
recommended to replace it every 3-6 months depending on application requirements.

! CAUTION

● Do not wash with hot water at more than 40°C. The filter may shrink.
● When washing it, shake off moisture completely and dry it in the shade; do not expose it directly to
the sun. The filter may shrink.
● Do not use detergent on the air cleansing and deodorizing filter as some detergent may deteriorate
the filter electrostatic performance.

– 30 –
MAINTENANCE
RAS-30CNHZ2

! CAUTION
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,
stop operation and switch off the power supply.

1. AIR FILTER
Clean the air filter, as it removes dust inside the room. In case the air filter is full of dust, the air flow
will decrease and the cooling capacity will be reduced. Further, noise may occur. Be sure to clean the
filter following the procedure below.
REMOVING METHOD

PROCEDURE

1 Open the panel and remove the filter


● Slightly lift the filter and release the claws from
the front cover.
● Gently lift and remove the air cleansing and
deodorizing filter from air filter frame. Front panel

2 Vacuum dust from the air filter and air cleansing


and deodorizing filter using vacuum cleaner. If
there is too much dust, rinse with clean water
and gently brush it with soft bristle brush. Allow Front cover
filters to dry in shade.
Claws Air filter

INSTALLATION METHOD

3 ● Re-insert the air cleansing and deodorizing


filter to the filter frame. Set the filter with
“FRONT” mark facing front, and slot them into
the original state.
● After attaching the filters, push the front panel
at three arrow portions as shown in figure
and close it.

NOTE:
● Air cleansing and deodorizing filter should be cleaned every month or sooner if noticeable loading
occurs. When used overtime, it may loose its deodorizing function. For maximum performance, it is
recommended to replace it every 3-6 months depending on application requirements.

! CAUTION

● Do not wash with hot water at more than 40°C. The filter may shrink.
● When washing it, shake off moisture completely and dry it in the shade; do not expose it directly to
the sun. The filter may shrink.
● Do not use detergent on the air cleansing and deodorizing filter as some detergent may deteriorate
the filter electrostatic performance.

– 31 –
2. Washable Front Panel

● Remove the front panel and wash with clean


water.
Wash it with a soft sponge.
After using neutral detergent, wash thoroughly
with clean water.

● When front panel is not removed, wipe it with


a soft dry cloth. Wipe the remote controller
thoroughly with a soft dry cloth.

● Wipe the water thoroughly.


If water remains at indicators or signal
receiver of indoor unit, it causes trouble.

Method of removing the front panel.


Be sure to hold the front panel with both hands
to detach and attach it.

Removing the Front Panel Attaching the Front Panel

Arm

Projection
Hole

Flange

● When the front panel is fully opened with ● Move the projections of the left and right
both hands, push the right arm to the inside arms into the Flanges in the unit and
to release it, and while closing the front panel securely insert them into the holes.
slightly, put it out forward.

! CAUTION
● Do not splash or direct water to the body of the unit when cleaning
it as this may cause short circuit.
● Never use hot water (above 40°C), benzine, gasoline, acid, thinner or
a brush, because they will damage the plastic surface and the coating.

– 32 –
! CAUTION
Cleaning and maintenance must be carried out only by qualified service personal. Before cleaning,
stop operation and switch off the power supply.

3. MAINTENANCE AT BEGINNING OF LONG OFF PERIOD

● Run the unit by setting the operation mode to


(COOL), the temperature to 32°C and the fan speed
to HI for about half a day on a fine day, to dry the
unit.
Air
● Switch off the power plug. Blow

REGULAR INSPECTION

PLEASE CHECK THE FOLLOWING POINTS BY QUALIFIED SERVICE PERSONAL EVERY


EITHER HALF YEARLY OR YEARLY. CONTACT YOUR SALES AGENT OR SERVICE SHOP.

Is the earth line disconnected or broken?


1

Is the mounting frame seriously affected by rust and is the


2 outdoor unit tilted or unstable?

– 33 –
AFTER SALE SERVICE AND WARRANTY

WHEN ASKING FOR SERVICE, CHECK THE FOLLOWING POINTS.

CONDITION CHECK THE FOLLOWING POINTS

● Is the fuse all right?


When it does not operate ● Is the voltage extremely high or low?
● Is the circuit breaker “ON”?

● Was the air filter cleaned?


● Does sunlight fall directly on the outdoor unit?
When it does not cool well ● Is the air flow of the outdoor unit obstructed?
When it does not hot well ● Are the doors or windows opened, or is there any source of
heat in the room?
● Is the set temperature suitable?

Notes
● In quiet operation or stopping the operation, the following phenomena
may occassionally occur, but they are not abnormal for the operation.
(1) Slight flowing noise of refrigerant in the refrigerating cycle.
(2) Slight rubbing noise from the fan casing which is cooled and then
gradually warmed as operation stops.
● The odor will possibly be emitted from the room air conditioner because
the various odor, emitted by smoke, foodstuffs, cosmetics and so on,
sticks to it. So the air filter and the evaporator regularly must be cleaned
to reduce the odor.

● Please contact your sales agent immediately if the air conditioner still fails to operate normally after the above
inspections. Inform your agent of the model of your unit, production number, date of installation. Please also
inform him regarding the fault.

● Power supply shall be connected at the rated voltage, otherwise the unit will be broken or could not reach the
specified capacity.

– 34 –
CONSTRUCTION AND DIMENSIONAL DIAGRAM
MODEL RAS-20CNHZ2 15

120
62

Air suction grill Top air suction grill Wireless remote controller
1 173 744 Front cover
Mounting
plate Cabinet

6.5
248

59
59

Discharge grill Horizontal air

5
5

45 P 45
Vertical air deflector deflector

147 450 (147)


VIEWED FROM BACK Drain cap connection part

23.5
(PIPE LEAD-OUT) 60 60
When piping is drawn
About 280 About 350 horizontally, exchange
the drain hose for the
42.5

Drain Pan drain cap.


About 290

Hole on the wall


for ø65 mm pipe Narrow pipe (ø6.35)
84 Line cord
Connecting cable Wide pipe (ø9.52)

MODEL RAS-30CNHZ2
786 15

120
62
Top air suction grill
Wireless remote controller
Air suction grill

798
Front cover
10 168
47

47
7

Mounting
plate
5.5
265

44 60 60 45
10
60

Viewed from P
60

(bottom direction pipe lead-out)


Discharge Horizontal Vertical air
5

47 grill air deflector deflector 47


P

174 450 (174)

87 58 58 Drain cap Note:


25

connection part 1. Servicing space of 100mm or more is required on the


left and right sides of the indoor unit and also 50mm or
Approx. more space is required above the unit.
Approx. 340 430 ❋ When piping 2. Insulated pipes should be used for both the narrow and
Drain outlet is drawn
Approx.

wide dia. pipes.


400

Drain hose Drain Pan horizontally,


exchange
43

the drain
hose for the
Viewed from back drain cap.
(Pipe lead-out) Hole on the wall
for ø65 mm pipe Narrow pipe (ø6.35)
94.5
Connecting cable Wide pipe (ø9.52)

– 35 –
MODEL RAM-50CNHZ2

340
26 850 79 22 298 20
64 104

Handle
Handle

638
650

169.5
96
Air suction Air outlet 201
grille

Holes for anchor bolt

More than
(2-ø12)
57
10

700
More than
100
320
340

More than
100
10

100
More than
Fixing hole 12
10

37
507 198

Notch for anchor bolt


Service space
(2-ø12 Notchs)

– 36 –
MAIN PARTS COMPONENT

THERMOSTAT

Thermostat Specifications

MODEL RAS-20CNHZ2, RAS-30CNHZ2

THERMOSTAT MODEL IC

OPERATION MODE COOL HEAT

INDICATION ON 14.3 (57.7) 24.3 (75.7)


16
OFF 13.6 (56.5) 25.0 (77.0)
TEMPERATURE ON 22.3 (72.1) 32.3 (90.1)
INDICATION
°C (°F)
24
OFF 21.6 (70.9) 33.0 (91.4)

INDICATION ON 30.3 (86.5) 40.3 (104.5)


32
OFF 29.6 (85.3) 41.0 (105.8)

FAN MOTOR

Fan Motor Specifications

MODEL RAS-20CNHZ2, RAS-30CNHZ2 RAM-50CNHZ2

POWER SOURCE DC: 5V, DC: 0 ~ 35V DC360V


OUTPUT 20W 40W

RED RED
360V
BLK
0V
CONNECTION YEL WHT
0~35V M 15V
YEL
M
5V 0~6V
BLU BLU
0~15V

(Control circuit built in)

BLU : BLUE YEL : YELLOW BRN : BROWN WHT : WHITE

GRY : GRAY ORN : ORANGE GRN : GREEN RED : RED

BLK : BLACK PNK : PINK VIO : VIOLET

– 37 –
COMPRESSOR MOTOR

Compressor Motor Specifications

MODEL RAM-50CNHZ2
COMPRESSOR MODEL GW20DN8A
PHASE SINGLE
RATED VOLTAGE AC 220 ~ 230 V
RATED FREQUENCY 50/60 Hz
POWER SOURCE FOR COMPRESSOR Vcc max = 360V
POLE NUMBER 4

(U) WHITE

CONNECTION

(W)
(V) YELLOW RED

20°C
(68°F) 2M = 1.05
RESISTANCE VALUE
( ) 75°C
(167°F) 2M = 1.28

WHITE

RED
YELLOW

CAUTION
When the refrigerating cycle has been operated for a long time with the capillary tubes clogged or crushed
or with too little refrigerant, check the color of the refrigerating machine oil inside the compressor. If the
color has been changed conspicuously, replace the compressor.

– 38 –
WIRING DIAGRAM
INDOOR UNIT
MODEL RAS-20CNHZ2, RAS-30CNHZ2

Connecting
Cord From Terminal
Outdoor Board
Brown
C
Red
D

Green &
CN10 M Indoor Fan
Motor
Yellow

MAIN P.W.B.
Room Black
Temperature Black
Thermistor
Gray CN1
Heat
Exchanger Gray
CN4 M Auto Sweep
Thermistor Motor

Light
Receiving CN2 TEST HA
Unit P.w.b CN6 CN7
X Lines
1 2 3 1 2 3 4
Wireless C1C2M1M2
Remote
Control
Detail Of X Lines
MODEL NAME X
RAS-20CNHZ2 7
RAS-30CNHZ2 6

– 39 –
WIRING DIAGRAM
OUTDOOR UNIT
MODEL RAM-50CNHZ2

– 40 –
CIRCUIT DIAGRAM
Remote Control

Key matrix table

Output D0 D1 D2 D3
Input

Door open Start/Stop Operation selection Fan speed selection Automatic swing
P10
Door shut Start/Stop Super silent cooling
1 SEG5 SEG20 40
2 SEG0 SEG19 39 Door open On timer Hour up Hour down
3 SEG1 SEG18 38 P11
4 SEG2 SEG17 37 Door shut Room temperature up Room temperature down Super cooling
5 SEG3 SEG16 36
6 SEG4 SEG21 35 Door open Off timer Reservation Cancel
7 SEG5 SEG24 34 P12
8 SEG6 SEG25 33 Door shut Sleep
9 SEG7 SEG26 32
10 COM3 SEG27 31
11 COM2 SEG28 30
12 COM1
LCD 1 NC 29
13 COM0 NC 28
14 SEG14 NC 27
15 SEG13 NC 26
16 SEG12 NC 25
17 SEG11 NC 24 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 48 47 46 45 44 43 42 41
18 SEG13 NC 23

SEG19
SEG18

SEG14
SEG17

SEG11
SEG16

SEG41
SEG13

SEG40
SEG12

SEG10
SEG15

SEG42
SEG43
SEG0
SEG1
SEG2
SEG4
SEG3
SEG9
SEG8

SEG5
SEG7
SEG6
19 SEG9 NC 22
20 SEG8 NC 21 65 SEG20
P30 40
66 SEG21 P31 39
67 SEG22 38
NCVL C1
68 SEG23 37
VL C2
69 SEG24
VL C3 36
70 SEG25
XC IN 35
71 SEG26 34
XC OUT
K1 K6 K13 K14 D0
72 SEG27 IC 1 VDD 33
73 SEG28
D3
74 SEG29
M3455OM6A-504FP VSS 32
RB425D(1/2) X OUT 31
75 SEG30 X IN 30
K2K3 76 SEG31 29
K7 K8 K15 K16 D1 RESET
77 SEG32 28
CARR
78 SEG33 27
P23
79 SEG34 26
P22
K4 80 SEG35 25
K8 K10 K17 D2 P21

BEEP
C8 D1 D2
P42
P43

P02
P00
P01
P40
P41

P10
P03

P20
P12
P13
P11

D3
D2
D1

D5
D4

D7
D0

D9
D6

D8
EL-1L7
50v/1u 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24
K5 D3
K11K12 K18 D3 RB425D
D1 D2 (1/2)
R6 R7 R8 R9
P11

P12
P10

R2 R3 R10 C9
100k 100k 12M 105 R14 R15
220k 100k
R6 R9 R11
24(1/8W) 150k
R1 SW1 X2
32.768 R13
100k SW-187-2P 220K
R5 Q1 X1 kHz
330 2SC3443 K19 910kHz
R4 or 2SC2982
P C6 C7 R16
100k
104 104 100k

C1
334 C2 C3 C4 C5 R12
220p 220p 18p 22p 220k

– 41 –
PRINTED WIRING BOARD LOCATION DIAGRAM
MODEL RAS-20CNHZ2 CN9 MAIN P.C.B
(EH-2P)

1
JUMPER
2 CN10
5V
THERMAL FUSE R101 (XH-3P)
35V
FOR TERMINAL POWER SUPPLY
(102 C) L101 ZD101 ICP1 12V
BROWN R104 RED
5
7 8 1 2 L102

R102
I O YELLOW INDOOR DC
+ + REG1 REG2 5V 3 M FAN MOTOR

C109
6 5

C106

C101
D101
- - + + BLUE
C 3 4

C107

C103
ZD102

ZD103
C108
1

C104
D102
-

R103
C102
C105 - G
RED C942
0V
R105
D Q901 L901
R106
CONNECTING R107

R912
CABLE TERMINAL ICP2

R919
BOARD R108 Q902
R109

D901
FAN MOTOR
R911 DRIVER
SHUNT
RESISTOR +

C901
R913

D902
-
5V 5V

R914

R920
5V CN8

R915

R406
R405
R916 (ZR-4P)
Q903 D401
4

R917
5V R403
3
R404 D403 EEPROM
2
5V

R931
1
R930 R932 5V
12V

D903
8 7 6 5 0V
0V
EXTENDED 12V

L501
IC401

C503
0V

C401
MEMORY BZ1 BZ

R801
1 2 3 4
IC501
CN6 12V

C504
9 CN4
(ZR-3P) 7 10 (ZR-5P)
+ + 0V
3

R401
R402
R524

R523
C933

C932

C702
6 11 1
R302 - -
TEST 2 0V 0V 0V 5 12 2
R307 A B STEPPING
1
R309 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 4 13 3 M MOTOR
ROOM TEMPERATURE

PWM
3 14 4

TXD
AVcc
C301

C302

C303

AN2
AN3
AN4
AN5
AN6
AN7

P16

P10
P30
P31
P32
IRQ1
IRQ3
C824

R310

R308

R303
ROOM
THERMISTOR 5V
REMOCON ID TEMP.
SDI 2 15 5
1 48

R607

R604

SDA
SCL

SDO
CN1

EXCHANGER
(A/B) AN 1 SWEEP RXD
RESISTANCE : 10K (25 C) W

HUMIDITY
DRAIN PUMP

HEAT

PWM FEEDBACK
1 16

FAN PWM OUTPUT


(PH-4P) 2 AN 0 PANEL 47

RPM OF PWM FAN


WIRELESS INPUT
TEST/FAST FEED
TEST PIN

EXTERNAL
P20 0V

ABNORMAL WATER LEVEL DETECTION


SELECT
B-CONSTANT : 3950K (B25/50) R522

WIRELESS ID SELECT
TEST INDICATOR MODE

ABNORMAL FAN CURRENT SENSOR

DC-FM OVER CURRENT DETECTION


8

ROM
3 AV S S 46

B
(Lo:ABNORMAL/Hi:NORMAL)
BLACK P87 R521
1 5V 5V DRIVER

R606
R608

R605
4 TEST

AUTO SWEEP MOTOR 2


45

A
BLACK P86 R520
2
5 X2 44

B
GRAY C502 P85 R519 0V
3 IF CIRCUIT
6 X1 43

A
D821

R829
B P84
R822

R826
GRAY

R824
4 R830 R518
3 7 Vss P83 42

B
8 R827
+ 1 Q821 OSC1 5V
HEAT EXCHANGER R821 2-

AUTO SWEEP MOTOR 1


C821 8 OSC1 P82 41

A
4 COM801
R823
C822

R210
THERMISTOR IC1

C823
(1/2)

R828
R825
9 OSC2 P81 40

B
R211 CN7
RESISTANCE : 10K (25 C) W 10 RESET (AX-7M12) (XH-4P)
P80 39

A
B-CONSTANT : 3950K (B25/50) C202 RES

C605
5V 0V 11 FLASH ROM WRITE IN CONTROL FILTER RESET 38 1 C1
0V R500 P90 P77 R525 0V
35V 5V 12 CURRENT SELECTION (20A/15A) BUZZER OUTPUT 37 2 C2
R501 P91 TMOV HA
13 INSTALLATION OF DUCT SYS (UP/DOWN) HA INPUT 36 3 M1
R502 P92 P75 R609
R809

R807

R803

R611
C601
TEST INDICATOR STATIC-PRESSURE SELECT 4 M2

R704
R805 14 35

R203
R813

R503 P93

ZD201
C802 5 AUTO SWEEP MOTOR 3 AMAND P74 R517 R610

OPERATION

HA OUTPUT
R812 Q803 R808 NICE TEMP.

POWERFUL
7 + 15 34

HOTKEEP
R810 Q801 A

2 WAY VAVLE
DRAIN PUMP
X1

HUMIDIFIER
P61 OPERATION
- 6 Q202 P94 DISABLE P73 R706

EXHAUST/
A B A B

TIMER
CN3 CN2 COM801

COMP
0V

DRY
Q802 Vcc 33

NC
RESET 16

POWERFULL
R804

(2/2) IRQ0
R811

INDICATING P.C.B 2 INDICATING P.C.B 1

R201
(ZR-7P) (SZN-7P)

FILTER/
C804

R204
C803

R806

C704

C501
P62
P63
P64

P66
P67

P55
P65

P56
P57
P50
P51
P52
P60

P53
P54
12V 5V
C801

R710 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
J1 R701 Q201 0V 0V

R206
R709 1 1 +

C201
V DD

R202

R504
R505
R506

R507
R508

R509
R510
R511
R512
R513
R514
R515
R516
JW1

IR701 0V 0V -
ZD701

3 2 2
LIGHT V OUT J2 NOTES:
RECEIVING 1 3 3 0V 1. TYPE
UNIT R705
J3
2 AUTO RESTART/ 4 4 F : FILM
TEMPORARY C : CERAMIC
GND +
D : ELECTROLYTIC
C701

5 5
- LD702 LD703
SW701

R703
(TIMER) (OPERATION)
6 6 2. FORM
NORMAL J4 R702
7 7
H: HAND INSERT
C: SMT
R: RADIAL
0V A: AXIAL

RESISTOR CAPACITOR TRANSISTOR IC LED CONNECTORS


SYMBOL RESISTANCE TOLERANCE POWER FORM SYMBOL RESISTANCE TOLERANCE POWER FORM SYMBOL RESISTANCE TOLERANCE POWER FORM SYMBOL RESISTANCE TOLERANCE POWER FORM SYMBOL RESISTANCE TOLERANCE POWER FORM SYMBOL CAPACITANCE TYPE FORM SYMBOL CAPACITANCE TYPE FORM SYMBOL MODEL NO. FORM SYMBOL MODEL NO. FORM SYMBOL MODEL NO. COLOR FORM SYMBOL MODEL NO. COLOR FORM REMARK
W W W W W F F Q201 2SC2462LC C REG1 MC34063AM C LD702 SLR-332DC3F ORANGE H CN1 PH 4P (TOP ENTRY) WHITE H ROOM,HEX. THERMISTOR
R101 1.0 –5% 1/4W C R307 1K –5% 1/16W C R510 10K –5% 1/16W C R610 1K –5% 1/16W C R821 1K –5% 1/16W C C101 220u,50V D (PF) H C601 0.1u,25V C C Q202 LD703 CN2
2SA1121SC C REG2 MC7805CT H SLR-332YC3F YELLOW H SZN 7P (TOP ENTRY) IVORY H TO INDICATING P.C.B.1
R102 10K –2% 1/16W C R308 12.7K –1% 1/16W C R511 10K –5% 1/16W C R611 10K –5% 1/16W C R822 10K –1% 1/16W C C102 100u,50V D (PF) H C605 C C CN3
IC1 HD6433644H C ZR 7P (SIDE ENTRY) IVORY H INDICATING P.C.B.1
R103 1.2K –2% 1/16W C R309 1K –5% 1/16W C R512 10K –5% 1/16W C R823 10K –1% 1/16W C C103 100u,10V D (UR) C Q801 IC401 BR24C02F
2SC4398 C C
R104 1.0 –5% 1/4W C R310 12.7K –1% 1/16W C R513 10K –5% 1/16W C R701 47 –5% 1/10W C R824 8.25K –1% 1/16W C C104 0.1u,25V C C C701 47u,10V D (WX) C Q802 IC501 ULN2003ANS OSCILLATOR CN4
2SA1121SC C C ZR 5P (TOP ENTRY) IVORY H AUTO SWEEP MOTOR
R105 1.5 –5% 1/4W C R514 10K –5% 1/16W C R702 390 –5% 1/10W C R825 10K –1% 1/16W C C105 220P,50V C C C702 1000P,50V C C Q803 MODEL FORM
2SC2618RC C SYMBOL
R106 1.5 –5% 1/4W C R515 10K –5% 1/16W C R703 200 –5% 1/10W C R826 1K –5% 1/16W C C106 0.22u,50V F H C704 0.1u,25V C C EF0S1005E5, 10MHz CN6
IR701 RPM6938-V4 H OSC1 C ZR 3P (TOP ENTRY) IVORY H TEST PIN
R107 1.5 –5% 1/4W C R516 10K –5% 1/16W C R704 10K –5% 1/16W C R827 3K –5% 1/16W C C107 0.047u,25V C C C801 150P,50V C C Q821 CN7
2SC2462LC C XH 4P (TOP ENTRY) BLACK H HA TERMINAL
R108 1.5 –5% 1/4W C R401 390 –5% 1/16W C R517 10K –5% 1/16W C R705 1K –5% 1/16W C R828 10K –5% 1/16W C C108 0.022u,50V C C C802 0.15u,50V F H Q901 CN8
2SJ245S C COM801 NJM2903M-T C ZR 4P (TOP ENTRY) IVORY H EEPROM
R109 1.5 –5% 1/4W C R402 390 –5% 1/16W C R518 10K –5% 1/16W C R706 1K –5% 1/16W C R829 5.1K –5% 1/16W C C109 56u,50V D (PF) H C803 C C Q902 INDUCTOR CN9
2SC2462LC C H THERM FUSE
R403 390 –5% 1/16W C R519 10K –5% 1/16W C R709 2K –5% 1/10W C C804 C C Q903 FORM CN10
2SC3360 C SWITCH SYMBOL RATED VALUE XH 3P (5P, TOP ENTRY) WHITE H FAN MOTOR
R404 390 –5% 1/16W C R710 2K –5% 1/10W C R830 5.1K –5% 1/16W C C201 100u, 4V D (WX) C FORM 82uH, 1.3A
SYMBOL MODEL L101 H
R201 5.1K –5% 1/10W C R405 5.1K –5% 1/16W C R520 10K –5% 1/16W C C202 0.1u,25V C C DIODE
SW701 JSM2220 H L102 560uH, 0.6A H
R202 2K –5% 1/16W C R406 5.1K –5% 1/16W C R521 10K –5% 1/16W C SYMBOL MODEL NO. FORM W 0.2A
L501 450 (100MHz), C
R203 2.7K –5% 1/16W C R522 10K –5% 1/16W C R801 3.3K –5% 1/10W C R911 1K –5% 1/4W C C821 0.01u,55V F C D101 G4DL-6140 H 450uH, 1,5A
L901 H
R204 5.1K –5% 1/16W C R523 10K –5% 1/16W C R803 120K –5% 1/16W C R912 47 –5% 1/10W C C822 1000p,50V C C D102 D1FS6 C BUZZER
R206 5.1K –5% 1/16W C R500 10K –5% 1/16W C R524 10K –5% 1/16W C R804 120K –5% 1/16W C R913 1K –5% 1/4W C C823 0.047u,16V F C SYMBOL MODEL FORM CHIP JUMPER
R501 10K –5% 1/16W C R525 10K –5% 1/16W C R805 120K –5% 1/16W C R914 1K –5% 1/4W C C824 0.01u,50V C C D401 DAN202K C BZ1 PKM13EPY H SYMBOL MODEL FORM
R502 10K –5% 1/16W C R806 120K –5% 1/16W C R915 1K –5% 1/4W C C301 0.1u,25V C C D403 DAP202K C JW1 C
R210 1M –5% 1/16W C R503 10K –5% 1/16W C R807 4.3K –5% 1/16W C R916 3.3K –5% 1/16W C C302 0.1u,25V C C C901 220u,50V D (PF) H ZENER DIODE JUMPER 0W
, 1/10W C
R211 0 –5% 1/16W C R504 10K –5% 1/16W C R604 1K –5% 1/16W C R808 4.3K –5% 1/16W C R917 3.3K –5% 1/16W C C303 0.1u,25V C C D821 DAN202K C SYMBOL MODEL FORM
R505 10K –5% 1/16W C R605 10K –5% 1/16W C R809 10K –5% 1/16W C R919 20K –1% 1/16W C C932 10u,16V D (WX) C ZD101 PTZ5.1 C IC PROTECTOR
R506 10K –5% 1/16W C R606 10K –5% 1/16W C R920 2.21K –1% 1/16W C C401 0.1u,25V C C C933 10u,16V D (WX) C D901 LFB01 C ZD102 PTZ20A C SYMBOL MODEL RATING FORM
R302 1K –5% 1/16W C R507 10K –5% 1/16W C R607 10K –5% 1/16W C R810 360 –5% 1/10W C D902 D1FL20U C ZD103 RLZ6.8A C ICP1 ICP-S0.5 0.5A C
R303 10K –5% 1/16W C R508 10K –5% 1/16W C R608 1K –5% 1/16W C R811 1K –5% 1/16W C R930 1K –1% 1/10W C C501 1u,16V C C C942 0.1u,25V C C D903 LFB01 C ICP2 CCP2E-50 2.0A C
R509 10K –5% 1/16W C R609 1K –5% 1/16W C R812 39 –5% 1/4W C R931 8.25K –1% 1/10W C C502 0.1u,25V C C ZD201 RLZ27D C
R813 39 –5% 1/4W C R932 5.1K –5% 1/16W C C503 0.1u,25V C C
C504 0.1u,25V C C ZD701 RD5.1UJN2 C
– 43 –
MODEL RAS-30CNHZ2 CN9 MAIN P.C.B
(EH-2P)

1
JUMPER
2 CN10
5V
THERMAL FUSE R101 (XH-3P)
35V
FOR TERMINAL ICP1 POWER SUPPLY
L101 ZD101 12V
(102 C) BROWN R104 RED
5
7 8 1 2 L102

R102
I O YELLOW INDOOR DC
+ + REG1 REG2 5V 3 M FAN MOTOR

C109
6 5

C106

C101
D101
- - + + BLUE
C 3 4

C107

C103
ZD102

ZD103
C108
1

C104
D102
-

R103
C102
C105 - G
RED C942
0V
R105
D Q901 L901
R106
CONNECTING R107

R912
CABLE TERMINAL ICP2

R919
BOARD R108 Q902
R109

D901
FAN MOTOR
R911 DRIVER
SHUNT
RESISTOR +

C901
R913

D902
-
5V 5V

R914

R920
5V CN8

R915

R406
R405
R916 (ZR-4P)
Q903 D401
4

R917
5V R403
3
R404 D403 EEPROM
2
5V

R931
12V
1
R930 R932 5V

D903
8 7 6 5 0V 12V
BZ1 BZ 0V
DRIVER

R801
EXTENDED

L501
IC401

C503
0V

C401
MEMORY
1 2 3 4 IC501

C504
9 12V CN4
CN6 7 10 (ZR-5P)
(ZR-3P)
0V 6 11 1
+ +
3

R401
R402
R524

R523
C933

C932

C702
- - 5 12 2
R302
TEST STEPPING
2
R307
0V 0V 0V
A B 4 13 3 M MOTOR
1 64 63 62 61 60 59 58 57 56 55 54 53 52 51 50 49 3 14 4
R309
ROOM TEMPERATURE

PWM

TXD
AVcc
C301

C302

C303

AN2
AN3
AN4
AN5
AN6
AN7

P16

P10
P30
P31
P32
IRQ1
2 15

IRQ3
C824 5

R310

R308

R303
ROOM
THERMISTOR 5V
REMOCON ID TEMP.
SDI
1 48

R607

R604

SDA
SCL

SDO
CN1 1 16

EXCHANGER
(A/B) AN 1 SWEEP RXD
RESISTANCE : 10K (25 C) W

HUMIDITY
DRAIN PUMP

HEAT

PWM FEEDBACK

FAN PWM OUTPUT


(PH-4P) 2 AN 0 PANEL 47 8

RPM OF PWM FAN


WIRELESS INPUT
TEST/FAST FEED
TEST PIN

EXTERNAL
P20 0V

ABNORMAL WATER LEVEL DETECTION


SELECT
B-CONSTANT : 3950K (B25/50) R522

WIRELESS ID SELECT
TEST INDICATOR MODE

ABNORMAL FAN CURRENT SENSOR

DC-FM OVER CURRENT DETECTION

ROM
3 AV S S 46

B
(Lo:ABNORMAL/Hi:NORMAL)
BLACK P87 R521
1 5V 5V

R606
R608

R605
4 TEST

AUTO SWEEP MOTOR 2


45

A
BLACK P86 R520
2 0V
5 X2 44

B
GRAY C502 P85 R519
3 IF CIRCUIT
6 X1 43

A
D821

R829
B P84
R822

R826
GRAY
R824
4 R830 R518
3 7 Vss P83 42

B
8 R827
+ 1 Q821 35V 5V OSC1 5V
HEAT EXCHANGER R821 2-

AUTO SWEEP MOTOR 1


C821 8 OSC1 P82 41

A
4 COM801
R823
C822

R210
THERMISTOR IC1

C823
(1/2)

R828
R825

9 OSC2 P81 40

B
R211 TEMPORARY CN7

R203
RESISTANCE : 10K (25 C) W (AX-7M12)

ZD201
10 RESET (XH-4P)
P80 39 SWITCH

A
B-CONSTANT : 3950K (B25/50) C202 RES
Q202

C605
5V 0V 11 FLASH ROM WRITE IN CONTROL FILTER RESET 38 SW1 1 C1
0V RESET R500 P90 P77 R525 0V

R201
12 CURRENT SELECTION (20A/15A) BUZZER OUTPUT 37 2 C2

R204
R501 P91 TMOV HA
13 INSTALLATION OF DUCT SYS (UP/DOWN) HA INPUT 36 3 M1
R502 P92 P75 R609
R809

Q201
R807

R803

R611
C601
R206
+ TEST INDICATOR STATIC-PRESSURE SELECT 4 M2

R601
R805 14 35
R813

C201
R202
C802 5 R503 P93 AUTO SWEEP MOTOR 3 P74 R517 R610
- AMAND

OPERATION

HA OUTPUT
R812 Q803 R808 NICE TEMP.

POWERFUL
7 + 15 34

HOTKEEP
R810 Q801 A

2 WAY VAVLE
DRAIN PUMP
X1

HUMIDIFIER
P61 OPERATION
- 6 P94 DISABLE P73 R602

EXHAUST/
A B A B

TIMER
COM801

COMP
0V

DRY
Q802 Vcc 33

NC
5V 16

POWERFULL
R804

(2/2) IRQ0
R811

0V

FILTER/
C804
C803

R806

C704
R709

C501
P62
P63
P64

P66
P67

P55
P65

P56
P57
P50
P51
P52
P60

P53
P54
C801

R708
17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32
R710 0V 0V SW2
Q702

R505
R506

R507
R508

R509
R510
R511
R512
R513
R514
R515
R516
INDICATING P.C.B (H-BOARD) CN2 0V 0V Q701
(PH-6P) AUTO RESTART NOTES:
5V SWITCH 1. TYPE
0V 0V
D701 D702 Q501
+ F : FILM
R707
C701

- C : CERAMIC
1 1 D : ELECTROLYTIC
LIGHT 0V Q502
RECEIVING 2 2

R711

R712
R713
UNIT R706 R705 0V 2. FORM
3 3
R704 H: HAND INSERT
Q503 C: SMT
4 4 R: RADIAL
R703 0V
A: AXIAL
5 5
R702
6 6
LD702 LD703 LD704 0V
(TIMER) (OPERATION) (FILTER)
0V

RESISTOR CAPACITOR TRANSISTOR IC LED CONNECTORS


SYMBOL RESISTANCE TOLERANCE POWER FORM SYMBOL RESISTANCE TOLERANCE POWER FORM SYMBOL RESISTANCE TOLERANCE POWER FORM SYMBOL RESISTANCE TOLERANCE POWER FORM SYMBOL RESISTANCE TOLERANCE POWER FORM SYMBOL CAPACITANCE TYPE FORM SYMBOL CAPACITANCE TYPE FORM SYMBOL MODEL NO. FORM SYMBOL MODEL NO. FORM SYMBOL MODEL NO. COLOR FORM SYMBOL MODEL NO. COLOR FORM REMARK
W W W W W F F Q201 2SC2462LC C REG1 MC34063AM C LD702 SLR-332MC3F GREEN H INDICATION
CN1 PH 4P (TOP ENTRY) WHITE H ROOM,HEX. THERMISTOR
PCB
R101 1.0 –5% 1/4W C R307 1K –5% 1/16W C R510 10K –5% 1/16W C R610 1K –5% 1/16W C R821 1K –5% 1/16W C C101 470u,50V D (PF) H C601 0.1u,25V C C Q202 LD703 INDICATION
CN2
2SA1121SC C REG2 MC7805CT H SLR-342YC3F YELLOW H PCB PH 6P (TOP ENTRY) WHITE H TO INDICATING P.C.B.
R102 10K –2% 1/16W C R308 12.7K –1% 1/16W C R511 10K –5% 1/16W C R611 10K –5% 1/16W C R822 10K –1% 1/16W C C102 150u,35V D (PF) H C605 C C LD704 INDICATION
IC1 HD6433644H C SLR-332VC3F RED H PCB
R103 1.2K –2% 1/16W C R309 1K –5% 1/16W C R512 10K –5% 1/16W C R702 200 –5% 1/10W C R823 10K –1% 1/16W C C103 100u,10V D (UR) C Q501 CN4
RN1414-TR C IC401 BR24C02F C ZR 5P (TOP ENTRY) IVORY H AUTO SWEEP MOTOR
INDICATION
R104 1.0 –5% 1/4W C R310 12.7K –1% 1/16W C R513 10K –5% 1/16W C R703 100 –5% 1/10W C R824 8.25K –1% 1/16W C C104 0.1u,25V C C C701 33u,10V D H PCB Q502 RN1414-TR C IC501 ULN2003ANS C
R105 1.5 –5% 1/4W C R514 10K –5% 1/16W C R704 100 –5% 1/10W C R825 10K –1% 1/16W C C105 220P,50V C C C702 1000P,50V C C Q503 OSCILLATOR CN6
RN1414-TR C ZR 3P (TOP ENTRY) IVORY H TEST PIN
R106 1.5 –5% 1/4W C R515 10K –5% 1/16W C R705 1K –5% 1/16W C R826 1K –5% 1/16W C C106 0.22u,50V F H C704 0.1u,25V C C Q701 COM801 NJM2903M-T MODEL FORM CN7
2SC2462LC C C SYMBOL XH 4P (TOP ENTRY) BLACK H HA TERMINAL
R107 1.5 –5% 1/4W C R516 10K –5% 1/16W C R827 3K –5% 1/16W C C107 0.047u,25V C C C801 150P,50V C C Q702 EF0S1005E5, 10MHz CN8
2SA1121SC C OSC1 C ZR 4P (TOP ENTRY) IVORY H EEPROM
INDICATION
R108 1.5 –5% 1/4W C R401 390 –5% 1/16W C R517 10K –5% 1/16W C R706 1K –5% 1/10W H PCB R828 10K –5% 1/16W C C108 0.022u,50V C C C802 0.15u,50V F H Q801 INDICATION
CN9
2SC4398 C IR-RECEIVER GP1U771R H PCB H THERM FUSE
INDICATION
R109 1.5 –5% 1/4W C R402 390 –5% 1/16W C R518 10K –5% 1/16W C R707 10 –5% 1/10W H PCB R829 5.1K –5% 1/16W C C109 56u,50V D (PF) H C803 0.1u,25V C C Q802 CN10
2SA1121SC C XH 3P (5P, TOP ENTRY) WHITE H FAN MOTOR
R403 390 –5% C R519 10K –5% C R708 5.1K –5% C C804 C C SWITCH
1/16W 1/16W 1/16W Q803 2SC2618RC C INDUCTOR
100u, 4V D (WX) SYMBOL MODEL FORM
R404 390 –5% 1/16W C R709 6.8K –5% 1/16W C R830 5.1K –5% 1/16W C C201 C Q821 2SC2462LC C SYMBOL RATED VALUE FORM
1/10W C C C R710 C C202 0.1u,25V C C SW1 SKHHANA010 H
R201 5.1K –5% R405 5.1K –5% 1/16W R520 10K –5% 1/16W 680 –5% 1/16W Q901 2SJ245S C 82uH, 1.3A H
L101
1/16W C C C R711 C SW2 JSA2220 H
R202 2K –5% R406 5.1K –5% 1/16W R521 10K –5% 1/16W 180 –5% 1/10W Q902 2SC2462LC C H
L102 560uH, 0.6A
R203 2.7K –5% 1/16W C R522 10K –5% 1/16W C R712 100 –5% 1/10W C R911 1K –5% 1/4W C C821 0.01u,55V F C Q903 DIODE
2SC3360 C L501 W 0.2A
450 (100MHz), C
R204 5.1K –5% 1/16W C R523 10K –5% 1/16W C R713 100 –5% 1/10W C R912 47 –5% 1/10W C C822 1000p,50V C C SYMBOL MODEL NO. FORM 450uH, 1,5A
L901 H
R206 5.1K –5% 1/16W C R500 10K –5% 1/16W C R524 10K –5% 1/16W C R801 3.3K –5% 1/10W C R913 1K –5% 1/4W C C823 0.047u,16V F C BUZZER D101 G4DL-6140 H
R501 10K –5% 1/16W C R525 10K –5% 1/16W C R803 120K –5% 1/16W C R914 1K –5% 1/4W C C824 0.01u,50V C C SYMBOL MODEL FORM D102 D1FS6 C CHIP JUMPER
R502 10K –5% 1/16W C R804 120K –5% 1/16W C R915 1K –5% 1/4W C C301 0.1u,25V C C BZ1 PKM13EPY H MODEL FORM
SYMBOL
R210 1M –5% 1/16W C R503 10K –5% 1/16W C R805 120K –5% 1/16W C R916 3.3K –5% 1/16W C C302 0.1u,25V C C C901 220u,50V D (PF) H D401 DAN202K C
JUMPER 0W
,1/10W C
R211 0 –5% 1/16W C R601 10K –5% 1/16W C R806 120K –5% 1/16W C R917 3.3K –5% 1/16W C C303 0.1u,25V C C ZENER DIODE D403 DAP202K C
R505 10K –5% 1/16W C R602 1K –5% 1/16W C R807 4.3K –5% 1/16W C R919 20K –1% 1/16W C C932 10u,16V D (WX) C SYMBOL MODEL FORM D701 DAP202K C
R506 10K –5% 1/16W C R604 1K –5% 1/16W C R808 4.3K –5% 1/16W C R920 2.21K –1% 1/16W C C401 0.1u,25V C C C933 10u,16V D (WX) C ZD101 PTZ5.1 C D702 DAP202K C IC PROTECTOR
R302 1K –5% 1/16W C R507 10K –5% 1/16W C R605 10K –5% 1/16W C R809 10K –5% 1/16W C ZD102 PTZ20A C D821 DAN202K C SYMBOL MODEL RATING FORM
R303 10K –5% 1/16W C R508 10K –5% 1/16W C R606 10K –5% 1/16W C R810 360 –5% 1/10W C R930 1K –1% 1/10W C C501 1u,16V C C C942 0.1u,25V C C ZD103 RLZ6.8A C ICP1 ICP-S0.5 0.5A C
R509 10K –5% 1/16W C R607 10K –5% 1/16W C R811 1K –5% 1/16W C R931 8.25K –1% 1/10W C C502 0.1u,25V C C D901 LFB01 C ICP2 CCP2E-50 2.0A C
R608 1K –5% 1/16W C R812 39 –5% 1/4W C R932 5.1K –5% 1/16W C C503 0.1u,25V C C ZD201 RLZ27D C D902 D1FL20U C
R609 1K –5% 1/16W C R813 39 –5% 1/4W C C504 0.1u,25V C C D903 LFB01 C
– 45 –
MODEL RAM-50CNHZ2 MOUNTING
R : RADIAL
TYPE
F : FILM
C : SMD C : CERAMIC
A : AXIAL D : ELECTROLYTIC
REACTOR H : HAND INSERT
YEL YEL
POWER P.W.B. L1 L2 SPM2 RESISTOR CAPACITOR TRANSISTOR IC
TERMINAL D25VB60 SPM2-CAPA
25A FUSE NF-COIL1 COMMON MODE COIL POWER RELAY + P1 P2 COMPRESSOR MOTOR RATING RATING RATING RATING

MOUNTING

MOUNTING

MOUNTING

MOUNTING

MOUNTING

MOUNTING
YEL

REMARK

REMARK

REMARK

REMARK

REMARK

REMARK
L MARK MARK MARK MARK MARK MODEL MARK MODEL

C001
VARISTOR1

C004
BLK C003 GRY ⍀ ⍀ ⍀

TYPE
% W % W % W V

C006
C011
SURGE R002 R003 IN RUSH CURRENT RELAY WHITE

3A FUSE
U
ABSORBER

R004
R001 JW3 + + + U V YELLOW R001 39 5% 1/4 A R280 100 5% 1/16 C 1608 R701 560K 5% 1/2 A C101 0.082 630 F H Q101 2SA673 R MICON AX-6M00 QFP

C005
- - - V
C002
VARISTOR3

W W R002 100 5% 10 H R281 100 5% 1/16 C 1608 R702 560K 5% 1/2 A C102 E2PROM S24CO2BFJ-TB SOP
RED
- N1 R003 100 5% 10 A R282 100 5% 1/16 C 1608 R703 100K 5% 2 A C103 0.1 50 C R Q201 RN2402 C SC-59
BLU
N 2125 C104 1000p 50 C R Q202 RN2402 C SC-59 IC1
WHT METAL COVER VARISTOR2 CN31 RED WHT WHT R004 470K 5% 1/2 A R283 360 5% 1/10 C STR-F6523 H
L007 CT1 METAL COVER 321 1 2 3 4 5 R005 2.2 5% 5 H R284 360 5% 1/10 C 2125 R708 10 5% 1/4 A C105 100 10 D R Q206 2SC2462LC C MPAK
GRN 1 DS WHT 29 27 26 25 CN12 CN13
R005

C008
C007

C017 0V

C021 C020
C103 C D R009 R285 R710 1.8K 5% 1/4 A C106 Q207 2SC2462LC C MPAK IC2

R011 R010
R009 + JW2 1 C E F G H I HD74HC4051FP SOP
GRN 2 A 0V C101 2
23 22 12 11 10 R010 470K 5% 1/2 A R286 2K 1% 1/16 C 1608 R711 75 5% 1/6 A C109 0.1 50 C R Q208 2SC2462LC C MPAK IC3 NJM2901M-TE1 SOP
JW5 C014 C015 C016 3 D
GRN 3 L006 + 30 R011 470K 5% 1/2 A R287 2K 5% 1/16 C 1608 R712 3.3K 5% 1/4 A C201 0.1 25 C C 1608 Q209 2SA1121SC C MPAK IC4 NJM2904M-TE3 SOP
8
C013 7 R101 3.6K 1% 1/6 A R288 1K 5% 1/16 C 1608 R713 8.2K 5% 1 H C202 2200p 50 C C 1608 Q280
B 1 24 IC5 NJM2903V-TE1 SOP
6
2
0V10 0V R102 3K 1% 1/6 A R289 1K 1% 1/16 C 1608 R714 3.3K 5% 1/4 A C203 2200p 50 C C 1608 Q501 2SC2462LC C IC6 M54567FP SOP
3 0V 28 27 26 25 24 23 22 21 20 19 18 17 16 15
FM-15V VCC 5 R103 30K 5% 1/6 A R290 10K 5% 1/16 C 1608 R715 680 5% 1/4 A C205 0.1± 50 D C ⵰4 Q502 2SC2462LC C IC7 M54567FP

SUB VCV

OC PGW
W
VCC VCU

A - NGU
SUT PGU

SVB PGV
V
VCW
U
FM

GL1 NGV
GL2 NGW
FM-15V R107
4 13 REF(5V) OUT 8
4 SOP
R115 5 0V12 ON/OFF

SWB
SWT
R104 3.9K 5% 1/6 A R291 4.7K 5% 1/16 C 1608 R716 0.39 5% 1 A C206 0.1 25 C C 1608 Q503 2SC2462LC C

SVT
SYNC 14 IC8 ULN2003ANS SOP

CB
0
3

A
F
R104

C106 R105
Q101 6 0V 11 CS VC 9
0V 1 2 3 4 5 6 7 8 9 10 11 12 13 14

ZD101
(7) (3) R105 7.5K 5% 1/6 A R292 3K 5% 1/16 C 1608 R717 JUMPER WIRE 1/4 A C207 0.047 50 C C 1608 Q504 2SC2462LC C
C109
SPS R103 D101 7
10 IDET CT 15
CN30 WHT R106 2.4K 5% 1/6 A R293 1.6K 5% 1/16 C 1608 R718 8.2 5% 1/4 A C208 0.1 25 C C 1608 Q505 2SC2462LC C
WHT C102 XH-7P 1 IFB OVP 4 REG1 MC7805CT H

R102
1 R101
(1) 2 IIN VFB 5 R107 1 1% 2 R R294 27K 5% 1/16 C 1608 R722 2.7K 5% 1/4 A C209 0.1 25 C C 1608 Q506 2SC2462LC C REG2 SE012N H
BLK
2 5V 3 VDET 6 9
GND VIN R108 1K 1% 1/6 A R295 5.1K 5% 1/16 C 1608 R723 33 5% 1/6 A C210 0.047 50 C C 1608
41 FM-0V 21
(5) + CN8B 7
R296 10K 5% 1/16 C 1608
PQ102 19 R109 510 5% 1/6 A R724 2.7K 5% 1/4 A C211 0.1 25 C C 1608 Q801 2SC2618RC C
WHT + WHT 32 18

D105
C104
R106
R109
0V 17 R110 1.69K 1% 1/6 A R297 1K 5% 1/16 C 1608 R725 JUMPER WIRE 1/4 A C212 0.1 25 C C 1608 Q802 2SC2618RC C
CN10 20
FM-0V 0V 13 14 15 16 R114 1K 5% 1/6 A R298 1K 5% 1/16 C 1608 R726 3.3K 5% 1/4 A C213 0.047 50 C C 1608
1 0V
(9) (4) R115 JUMPER WIRE A R301 3.74K 1% 1/16 C 1608 R730 C214 0.068 16 C C 1608 Q831 2SC1214CT R
2 1 28 2

W+
17V
C C 1608

U+

U+
1/16 C 1608 C215

W-
R302 3.01K 1% 0.1 25

V+
OV

V-

IP
Id
R114 5 4 3 2 1
E F GH I
1 2 3 4 5 6 7 8 9 10 R201 10K 5% 1/16 C 1608 R303 3.01K 1% 1/16 C 1608 R801 3g 5% 1/4 C C216 4700p 50 C C 1608
0V
CN11 GRY CN13 WHT CN14 GRY ZENER DIODE DIODE
1 2 3 4 5 8 5 4 3 2 1 R202 10K 5% 1/16 C 1608 R304 100 5% 1/16 C 1608 R802 3g 5% 1/4 C C217 0.047 50 C C 1608
54 3 2 1 10 9 7 6

MOUNTING

MOUNTING
R203 2K 5% 1/16 C 1608 R305 100 5% 1/16 C 1608 R803 3K 5% 1/16 C C218 0.068 16 C C 1608

REMARK

REMARK
+5V +12V T MARK MODEL MARK MODEL
C105
R108

D104 R110 + C203 C404 L R204 2K 5% 1/16 C 1608 R306 100 5% 1/16 C 1608 R811 3g 5% 1/4 C C219 4700p 50 C C 1608

+
-
GRY 0V R205 2K 5% 1/16 C 1608 R308 2K 2% 1/16 C 1608 R812 3g 5% 1/4 C C220 22 6.3 D C ⵰4

R603
SWITCHING TRANS C608 R604
+17V CN3 CN3A
+17V
K 3 IC3 J K
R206 10K 5% 1/16 C 1608 R309 2K 2% 1/16 C 1608 R813 3K 5% 1/16 C C221 0.1 25 C C 1608
D101 1GH46 A
R717 D713 0V 0V
+ 7 ZD101 D102

R601
1S2076A A

R602
16 +C718 11 1 J 1 R605 R207 10K 5% 1/16 C 1608 R310 2K 2% 1/16 C 1608 C222 0.1 25 C C 1608
R712 - 6
17
10 2 ZD201 RLZ6.8A C LLDS D103 1S2076A A
FM-15V 9 3 + 5
R208 200 5% 1/10 C 2125 R311 2K 2% 1/16 C 1608 R831 10K 5% 1/6 A C223 0.1 25 C C 1608
1 R718 D710 2 R606 D104 1SS120 A
18 + 8 4 - 4 R209 200 5% 1/10 C 2125 R312 10K 1% 1/16 C 1608 R832 7.5K 5% 1/2 A C224 10 16 D C ⵰3
R702 R701 R703 C714 C707 R714 7 5 +12V D105 1SS120 A
19
+12V +5V 13
+ 11
R607
R210 200 5% 1/10 C 2125 R313 5.1K 5% 1/16 C 1608 R833 620 5% 1/6 A C225 0.1 25 C C 1608 LED
C735 FM-0V 6 6 - 10 D201 DAN202K C SC-59
D709 5 7 +5V R211 200 5% 1/10 C 2125 R314 C226 0.1 25 C C 1608

MOUNTING
13 REG1 + 9 D202 DAP202K C SC-59

REMARK
9 D705 + + 4 8 D203 14 17V R212 2K 5% 1/16 C 1608 C227 0.1 25 C C 1608 MARK MODEL
C708 C721 C716 C402 + + - 8 R315
C403 D203 DAP202K

R608
R609
R610
R611
3 9 C SC-59

C604
C603
C602
C601
1/16 C 1608 R316 1K 5% 1/16 C 1608

R501
R502
R503
R504
R505
R506
IC1 14 +5V +5V 12 R214 10K 5% C228 0.1 25 C C 1608
C709

D702 R708 + 2 10 D204 DAN202K


3 4 Q202 C SC-59
12 R723 D706 0V 1 11 0V R215 10K 5% 1/16 C 1608 R317 1K 5% 1/16 C 1608 C280 2.2 50 D C ⵰4 LD301 LT1D67A C

R507
R508
R509
R510
R511
R512
15 D205 DAN202K C SC-59
C731 + R284 Q201 R318 1K 5% 1/16 C 1608 LD302 LT1D67A C
D703

1 -5V -5V R216 10K 5% 1/16 C 1608 C281 0.01 50 C C 1608


20 R521 Q501
D206 DAN202K C SC-59
2 5
C734 C740 BLU R283 R217 10K 5% 1/16 C 1608 R319 1K 5% 1/16 C 1608 CAPACITOR LD303 LT1D67A C
C722

D716
C723

FB1 11 R279 R522 D207 DAN202K C SC-59


R722 21 CN4 R218 10K 5% 1/16 C 1608 R320 1K 5% 1/16 C 1608 C301 0.1 25 C C 1608 LD304 LT1K67A C
Q502 RATING
R713

R531

MOUNTING
+
C710

D715 R724 D707


R716

REMARK
11 12 +12V R532 R523 Q503 R219 10K 5% 1/16 C 1608 R321 MARK C302 0.1 25 C C 1608
R715

TYPE
C733 22 10 13 IC8 R524 V D702 1GH46 A
9 R220 1M 5% 1/16 C 1608 R322 C303 0.1 25 C C 1608 INDUCTOR
9 14 1 R533 Q504 D703 1SS120
C732 C822 R710 16 M
R221 10K 1% 1/16 C 1608 A
1 8 15 15 2 R534 R525Q505 R323 10K 5% 1/16 C 1608 C001 0.01 AC250 C R C304 1 16 C C 2125
4 R711 N
POWER RELAY COIL

D705 RN2Z

MOUNTING
12V 12V H
IN RUSH CURRENT

1 7 16 14 3 R526 R222 510 5% 1/16 C 1608 R324 10K 5% 1/16 C 1608 C002 0.01 AC250 C R C305 1 16 C C 2125

REMARK
R726 D725 MARK MODEL
RED 2 2 Q506
REG2

D706 AK04
D103

3 6 17 13 4 A
D102

D708 PQ8 R535


RELAY COIL

CN2 C724 5 18 12 5 R536 R226 10K 5% 1/16 C 1608 R325 1K 5% 1/16 C 1608 C003 0.56 630 F H C306 1 16 C C 2125
REVERSING VALVE 3 O D707 RN3Z H
R725 4 19 11 6 +5V R227 10K 5% 1/16 C 1608 R326 2.7K 5% 1/16 C 1608 C004 C307 1 16 C C 2125
3 L006 EXCEL SA35V A
D831 +5V 3 20 10 7 0V D708 JUMPER WIRE A
4 1 8 C202 R231 10K 5% 1/16 C 1608 R327 470 5% 1/16 C 1608 C005 C308 1 16 C C 2125 L007

R274
R275
2
1 2 21 E PROM D709 RU1P A
PQ831 + 1 22 C210 8 1 C211 R232 10K 5% 1/16 C 1608 R328 1.6K 5% 1/16 C 1608 C006 4.0 AC400 F H C309 0.1 25 C C 1608
NF COIL 3
Q831

3 2 C736 0V 0V +5V D710 1GH46 A


7 2
R832 6 3
R233 100 5% 1/16 C 1608 R329 4.3K 5% 1/16 C 1608 C007 0.01 AC250 C R C402 100 10 D C ⵰6.3 L801 100uH H
R831 R278
D713 1GH46 A
R833
5 4 R234 10K 5% 1/16 C 1608 R330 10K 5% 1/16 C 1608 C008 0.01 AC250 C R C403 100 25 D C ⵰8 L802 100uH H
D201 D715 1SS120 A
RED
0V
R235 10K 5% 1/16 C 1608 R331 10K 5% 1/16 C 1608 C010 C404 33 25 D C ⵰6.3 L803 FBA04MA450 H D716 1S2473 A
R243 R236 10K 5% 1/16 C 1608 1/16 C 1608 C601 680p 50 C C 2125
R240

BRN +12V 4 E2PROM R332 10K 5% C011 L804 FBA04MA450 H


R276
C607
C606
C605

R730 3 R237 5.1K 5% 1/16 C 1608 R501 1K 5% 1/16 C 1608 C602 680p 50 C C 2125
R242

L801 CN17 WHT C013 0.01 AC250 C R


R236 R237
R238 R244
C209

R235
D202 R277 5V D801
TERMINAL CN1 WHT 0V INTERFACE RELAY 10V 2 HN2DO1FU-TE85L C
0V 1 R238 100 5% 1/16 C 1608 R502 1K 5% 1/16 C 1608 C014 0.01 AC250 C R C603 680p 50 C C 2125 FB1 BL01RN1 A
BRN C803 C820
C 1
R503 1K 5% 1/16 C 1608 C604 680p 50
C804 C806 R239 100 5% 1/16 C 1608 C015 0.01 AC250 C R C C 2125 CT1 S19-J299CT H
R239
C207

INDOOR 1 L803 0V D831 1SS120 A


C807 1608
D 3 C805 R240 1K 5% 1/16 C 1608 R504 1K 5% 1/16 C C016 0.01 AC250 C R C605 1000pF 50 C C 1608
RED NF COIL 2 5V C201
+5V 20 19 18 17 16 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 R242 10K 5% 1/16 C 1608 R505 1K 5% 1/16 C 1608 C606 1000pF 50 C C 1608
C017 0.01 AC250 C R
R811
(2.7A)

U+
C
B

Ø60
POR

W+
V+

V-
SCL(E2PROM)

NF COIL 5
A
FM-60˚el

W-

U-
IF-CLOCK

IPCUT
SDA(E2PROM)
Vss

NC
FORCE COOL
ICP1

+12V 21 Vcc G R243 100 5% 1/16 C 1608 R506 1K 5% 1/16 C 1608 C607 1000pF 50 C C 1608
NC 80 R234
L802 C811 R812 Q802 22 ACT-CHOP 79 R233 PHOTO COUPLER
R201 CHING R244 2K 5% 1/16 C 1608 R507 5.1K 5% 1/8 C 3216 C020 220 200 D H C608 0.1 25 C C 1608
TERMINAL 0V INTERFACE RELAY 20V R813 23 2 WAY VALUE PAM 78 R232
BLU C818 R202 24

MOUNTING
C813 C821 C812 4 WAY VALUE ACT ON/OFF 77 O +5V R245 5.1K 5% 1/16 C 1608 R508 5.1K 5% 1/8 C 3216 C021 220 200 D H
C 5

REMARK
C814 C816 + 0V 0V 25 76 MARK MODEL
INDOOR 2 L804 C817 C737 0V R219 OPERATION RELAY R231 +5V R285 R509 5.1K 5% 1/8 C 3216 C707 100 25 D R
D 7 C815 D801 26 IN RUSH RELAY FANCHOP 75 N SURGE ARRESTER
YEL NF COIL 4 27 POWER RELAY 74 C227 C208 R247 3.16K 1% 1/16 C 1608 R510 5.1K 5% 1/8 C 3216 C708 330 25 D R

D204

R286
+5V R227 P IC4 PQ8 PS2501 H

MOUNTING
LD301 28 SELF DIAGNOSIS 1 73 8
R801

A B R203 29 R226 R248 1K 5% 1/16 C 1608 R511 5.1K 5% 1/8 C 3216 C709 180 10 D R

REMARK
LD302 SELF DIAGNOSIS 2 MICON SD02 72 PQ831 PC817X H MARK MODEL
C801 R802 Q801 LD303 R204 30
71
C228
1 - 2 R249 20K 1% 1/16 C 1608 R512 5.1K 5% 1/8 C 3216 C710 330 50 D R
Vss SD12 + 3 PQ102 PS2501
C808
LD304
R205
31 SELF DIAGNOSIS 2 AX-6M00 SD01 70 R287 + R288 R250 10K 5% 1/16 C 1608 R521 10K 5% 1/16 C 1608 C714 0.01 1KV C H
H
R803

R249
C802 32 SD11 69 VARISTOR 1 450NR-12D R

C280
R212 R206 15/20A R251 10K 5% 1/16 C 1608 R522 10K 5% 1/16 C 1608 C716 330 10 D R
0V 0V 33 COOLING O/P AVcc 68 L VARISTOR 2 450NR-12D
+5V
0V R207
34 HEATING O/P VREF 67 7 - 6 C718 JUMPER WIRE R
NORMAL R296 C206 R + 5 R253 3.32K 1% 1/16 C 1608 R523 10K 5% 1/16 C 1608 220 25 D R
+12V 35 2A 2S VALVE PIPE 1.2, 3S VALVE PIPE 1.2, FN, FAST FEED 66 R248 VARISTOR 3 450NR-12D R
+5V + R245 C721 0.1 50 C R
WHT SERVICE-SW R254 100 5% 1/16 C 1608 R524 10K 5% 1/16 C 1608

MOUNTING
36 2B 4
1B ELECTRIC

65
ADS0 THERMISTOR

C220
ADS1 EXCHANGER

R210
WDT VALVE

REMARK
CN16 6 37 2A OUTDOOR TH. 64 R255 2K 5% 1/16 C 1608 R525 10K 5% 1/16 C 1608 C722 MARK MODEL
R211 COOL

R247
R289
5 16 9 1 8 IC7 38 2B DEF 63 SURGE
0V R256 10K 5% 1/16 C 1608 R526 10K 5% 1/16 C 1608 C723 470P 2KV C R ABSORBER DSA-102MA-05F25 H
4 2 3 39 1A OH 62
RESET

}
EXTAL

M
ADS2
STBY

RES0
XTAL

40 1B
AVss

JW2 NONE A
MD1
MD0

3 15 14 Is 61 R257 3K 5% 1/16 C 1608 R531 5.1K 5% 1/16 C 1608 C724 0.1 50 C R


NMI
Vss

Vcc

Vd
1A

R222
Id
Ø

2 7 6 R258 1K 5% 1/16 C 1608 R532 5.1K 5% 1/16 C 1608 JW3 NONE A


ELECTRIC EXPANSION 41 42 43 44 45 46 47 48 49 50 51 52 53 54 55 56 57 58 59 60 R221 C725
1 10 11
CONNECTOR
R214
R251

R215

R217

R218

VALVE (INDOOR 2) C226 C221 R259 8.25K 1% 1/16 C 1608 R533 5.1K 5% 1/16 C 1608 C731 100 25 D R
4 5 12 13
RED
R208 +5V D205 R260 10K 1% 1/16 C 1608 R534 5.1K 5% 1/16 C 1608 C732 470P 50 C R JW5 NONE A
R250

R216

CN15 6 R220

REMARK
R209 C 1608 C733 1000pF 50 C R MARK MODEL
5 16 9 1 8 IC6 T
R261 10K 1% 1/16 C 1608 R535 5.1K 5% 1/16
4 2 3 C 1608 C734 1000pF AC250 C R JW7 NONE C 1608
M 3 15 14
X1 R262 10K 1% 1/16 C 1608 R536 5.1K 5% 1/16
R263 1/16 C 1608 C735 1000pF 50 C H JW8 NONE C 1608 CN1 VH-4P WHITE
2 7 6 P 1K 5%
ELECTRIC EXPANSION CN2 VH-2P RED
1 10 11 R264 100 5% 1/16 C 1608 C736 68 50 D R JW9 NONE C 1608
R253

VALVE (INDOOR1)
C281
C205

C225 4 5 12 13 +
Q280 C212 R265 2K 5% 1/16 C 1608 R601 2K 5% 1/16 C 1608 C737 68 50 D R JW10 NONE C 1608 CN3A MINICT-22P 2 ROWS
WHT +5V
R266 10K 5% 1/16 C 1608 R602 2K 5% 1/16 C 1608 C740 470P AC250 C R CN3 MINICT-11P GRAY
OH THERMISTOR CN5 0V
R110:1.28k⍀⫾5% 0V CN4 MINICT-11P BLUE
1
R304 R267 3K 5% 1/16 C 1608 R603 2K 5% 1/16 C 1608
B100/110: 2
4400K⫾150K R305 R268 1K 5% 1/16 C 1608 R604 100 5% 1/16 C 1608 C801 0.15 50 F C CN5 XA-2P WHITE
BLK
C303
C302
C301

DEF THERMISTOR R306 CN6 XA-2P BLACK


SWITCH
R301
R302
R303

CN6 R269 8.25K 1% 1/16 C 1608 R605 100 5% 1/16 C 1608 C802 0.022 16 F C
RO:5.9k⍀⫾5% 1
R270 10K 1% 1/16 C 1608 R606 100 5% 1/16 C 1608 C803 0.15 50 F R CN7 XA-2P RED
BO/25:3400⫾2% 2

MOUNTING
RED CN8

REMARK
BLK +5V 0V R271 10K 1% 1/16 C 1608 R607 100 5% 1/16 C 1608 C804 0.01 AC250 C H MARK MODEL
OUTDOOR THERMISTOR CN7 +5V
1 0V +5V +5V CN8B VH-2P WHITE
R272 10K 1% 1/16 C 1608 R608 4.02K 1% 1/16 C 1608 C805 0.01 AC250 C H
R272
R262
R269
R259

R35:1.433k⍀⫾2%
R255
R258

2 8
C215

+5V C309 CN9 PH-8P WHITE


R321

BO/70:3400K⫾2% C 1608 SERVICE-SW KSM0612BTS R


R322

WHT R273 1K 5% 1/16 C 1608 R609 4.02K 1% 1/16 C806 0.01 AC250 C H
IC2 3 +
R314

CN8 R263 1 C 1608 CN10 XH-2P WHITE


C213

R274 5.1K 5% 1/16 C 1608 R610 4.02K 1% 1/16 C807 0.01 AC250 C H
2 -
C216

ELECTRIC EXPANSION 1
16
R257 Q206 R254
R256

15 X2 X 3 12V +5V CN11 MINICT-5P WHITE


C214

VALVE THERMISTOR 2 R313 R316 R280 D206 R275 5.1K 5% 1/16 C 1608 R611 4.02K 1% 1/16 C 1608 C808 0.1 25 C C 1608
R35:1.433k⍀⫾2% 14 X1 C 9 5 + 0V
OSCILLATOR
WHT
R295 R294 R292 ZD201

JW7 R273 7 +5V R276 390 5% 1/16 C 1608


ÇR290

+5V
6 -
C219

BO/70:3400K⫾2% R317 13 X0 B 10
R265

RED CN9
R271
R261

R268

MOUNTING
WHITE
R270
R260

1 5 X5 A 11 0V R277 390 5% 1/16 C 1608 C811 0.15 50 F C CN13 CT-5P

REMARK
SMALL PIPE (INDOOR 1) RED MARK MODEL
2 JW8 R323 4
R318 2 X6 X3 12 IC5 CN14 MINICT-10P WHITE
R330
R331
R332

BLK S Q208 C812 0.022 16


R278 JUMPER 5% 1/16 C 1608 F C
C217

3 R324 X7 Q209 R267 Q207 R264


INH

R266

LARGE PIPE (INDOOR 1) BLK R291


C222 R293

4 8 CN15 XA-6P RED


X4

C223

4 JW9
C218

R319 0V D207 R279 C813 0.15 50 F R


GRY X1 CSTCS16.OMHZ C
C224

5 1 6 7
SMALL PIPE (INDOOR 2) GRY M + 0V C814 0.01 AC250 C H CN16 XA-6P WHITE
6 JW10
BLU R320 CN17 PH-4P WHITE
BLU
7 +5V 0V R 0V C815 0.01 AC250 C H
+17V

LARGE PIPE (INDOOR 2)


ICP
R308
R309
R310
R311
R312
R315

C304
C305
C306
C307
C308

8 CN18
+5V

R325 G C816 0.01 AC250 C H ZR-12P WHITE


0V 0V 0V
R281

R282

R297
R327
R328
R329

0V
R326

0V C817 0.01 AC250 C H CN19

MOUNTING
+12V

5V

REMARK
MARK MODEL
R298

CN20 ZR-4P WHITE


0V
-5V

C818 0.1 25 C C 1608


0V 0V 0V 0V C820
MAIN P.W.B.
1 2 3 4 1 2 3 1 2 3 3 5 6 7 8 9 10 11 12 ICP1 ICP-M75(2.7A) R CN30 XH-7P WHITE
CN20 WHT C821
1/1000 CN19 WHT CN18 WHT CN31 VH-2P WHITE
1/100 C822 470P AC250 C H
1/10 TEST PIN
FAST FEED

– 47 –
BLOCK DIAGRAM

INDOOR OUTDOOR
MODEL RAS-20CNHZ2 MODEL RAM-50CNHZ2
FM Outdoor fan motor
Power source1 ¿50Hz, 220-240V
Wireless receive
LCD wireless L
circuit

Room temperature Buzzer circuit


N
Magnetic relay PAM Power
circuit
Power module
M
thermistor Inrush current DC compressor
Operation. Protection circuit motor

Indoor micro computer (AX-7M12)


Indicating lamp
Timer.

Indoor Unit 1
C
Auto sweep motor for
M Air deflector
Heat exchanger D Rotor pole position
temperature

Upper arm drive


synthesis circuit
thermistor Terminal desition detector
Board

Trip signal
Indoor / Outdoor C
Temporary switch /
interface circuit D

circuit
Auto Restart Peak current cut off
Initial setting circuit
DC fan motor
circuit drive circuit

Reset circuit Peak current

Outdoor micro computer (6M00)


Overload external cut off

Lower arm drive


judgement circuit
Micro computer FM Indoor fan motor
clock circuit

circuit
Voltage amplification
circuit

Self-diagnosis
MODEL RAS-30CNHZ2
Over heat thermistor

Relay drive
circuit
Wireless receive
LCD wireless
circuit Defrost thermistor

circuit
Room temperature Buzzer circuit
thermistor Outdoor temperature thermistor
Operation.

Electric Expansion
Indoor micro computer (AX-7M12)

Indicating lamp Timer.

valve drive circuit


Dehumidifying. Indoor / Outdoor
interface circuit 1
Indoor Unit 2
C
Indoor / Outdoor
M
M Auto sweep motor for interface circuit 2 Electric
Heat exchanger Air deflector D expansion valve
temperature Clock

Relay circuit
thermistor Terminal circuit
Board
Auto-restart
Indoor / Outdoor C
Temporary switch interface circuit Reversing valve coil Power circuit
D
(For Indoor 2 P.W.B)
Initial setting DC fan motor
circuit drive circuit
Power circuit
Reset circuit
(Indoor and outdoor P.W.B)
DC35V

Micro computer FM Indoor fan motor


clock circuit

– 49 –
BASIC MODE
MODEL RAM-50CNHZ2

– 51 –
New Cool Rhythm Cooling Sleep Operation

Room temperature Final set temperature


Minimum Minimum Minimum Minimum (Cooling/dehumidifying set
5min. 5min. Minimum 5min. 5min. 5min. 5min. 5min. 5min. Minimum 5min. 5min. 5min.
temperature (+) sleep shift)
Final set temperature

SFCMIN
(shift lower limit)

(Cooling/dehumidifying
set temperature
(temperature set by remote (Cooling/dehumidifying set 0.5hr 1.5hr 2.5hr 3.5hr 6hr 7hr
control (+) SHIFTC) temperature = Remote control set
temperature (+) SHIFTC) 3hr
Set to 7 hours
Set temperature during rhythm
(temperature set by remote control Sleep key
(+) SFTRZM)
Operation lamp

Timer lamp

Thermo judgment Thermo OFF


Indoor fan Hi
See basic operation
Med
1 cycle Lo (sleep)

Hi 5 sec. 2.5 sec. 5 sec. 2.5 sec. Outdoor fan Lo


Lo 4.5 sec. 2.5 sec.
Indoor See basic operation.
New cool rhythm

Rhythm Med
fan

Compressor speed
Rhythm Lo Maximum speed
Med
15 sec.
Outdoor fan Lo Lo P1
Compressor speed

Notes:
(1) The sleep operation starts when the sleep key is pressed.
(2) 30 minutes after the sleep key is set, the sleep shift of temperature starts, and upper shift is made
at least 6 times. If 25˚C is not reached after 6 shifts, shifts repeat unit 25˚C is reached.
(3) The sleep shift upper value of set temperature is 28˚C.
(4) After 6 hours, a shift down to the initial set temperature is made at a rate of 0.33˚C/5 min.
(5) If the operation mode is changed during sleep operation, the set temperature is cleared, and shift
Notes: starts from the point when switching is made.
(1) New cool rhythm is engaged when the fan speed is “auto” and the room temperature is less than (6) The indoor fan speed does not change even when the fan speed mode is changed.
set one plus 0.66˚C in the “auto” operation mode or cooling mode. (7) When operation is stopped during sleep operation, the set temperature when stopped, as well as the
(2) The minimum new cool rhythm time is 10 minutes when the temperature falls and rises. time, continue to be counted.
(3) Cool rhythm is not engaged during Nice temperature, Sleep operation. (8) If the set lime is changed during sleep operation, all data including set temperature, time, etc. is
(4) Pl control is engaged during new cool rhythm: the speed limit is the same as during normal operation. cleared and restarted.
(5) The new cool rhythm set temperature is also shifted during thermo OFF. (9) If sleep operation is canceled by the cancel key or sleep key, all data is cleared.

– 53 –
rotation speed

Notes:
(1) 30 seconds after the operation is started, when the room temperature is (cooling preset temperature) - (1.33˚C) or less, the operation is
done assuming as the preset temperature = (room temperature at the time) - (2˚C).
(2) The indoor fan is operated in the “Lo” mode, OFF for 5 minutes and ON for 1 minute (at high humidity) or OFF for 6 minutes and ON for
1 minute (at low humidity), repeatedly according to the humidity judgement when the thermostat is turned OFF.
(3) When the operation is started by the thermostat turning ON, the start of the indoor fan is delayed 32 seconds after the start of compressor
operation.
(4) The compressor is operated forcedly for 3 minutes after operation is started.
(5) The minimum ON time and OFF time of the compressor are 3 minutes.

– 55 –
– 57 –
– 59 –
DEFROST
● Reversing valve defrost system is employed: it consists of balancing period → reversing cycle period →

balancing period.
(1)Defrost start condition
● When all the following conditions are established, defrost is executed:

1 Normal operation
2 Heat exchange temperature is within defrost range specified by outdoor temperature and heat
exchange temerature.
3 Defrost inhibit period linked to outdoor temperature has passed.
(2)Defrost release condition
● If any one of the following conditions is established, defrost is released:

1 Heat exchange temperature returns (heat exchange temperature ⭌ DEFOFF).


2 Defrost max time of 12 minutes has elapsed.
● Released by condition 1 during balancing period: When remaining balancing period has elapsed,
returned to initial condition (ASTUS = 0).
● Released by condition 1 2 or during reversing cycle period: Shifted to balancing period.
(3)Outputs during defrost
● Indoor defrost request: Transmitted to all units being operated in heating mode.

● Compresor: Balancing period for [TDF414] seconds → Starting of reversing cycle period by [SDRCT2]

min-1 for [TSKTM2] seconds → Accelerating by [DFCTEP] min-1 / [TDFSPT] seconds in


remaining reversing cycle period until defrost MAX speed [DEFMAX] is reached →
Balancing period for [TDF415] seconds
● Electric expansion valve

Unit being stopped : [FULL CLOSE] 30 seconds after balancing period has passed →
[FULL CLOSE] during reversing cycle period → [PCLOSH] 15
seconds before balancing period is finished.
Unit being operated : [DFCTPS] 30 seconds before balancing period is finished →
Synchronized with step-up of rotation speed of compressor, opened
by [DFSPPS] pulses and reaches MAX opening degree [DEFSMX]
when rotation speed of compressor reaches [DEFMAX].

– 60 –
● Time chart when executing defrost (both unit 1 and unit 2 operated)

Defrosting signal

Request Compressor Operation


Unit 1
Unit 2
Unit 1
Unit 2
Unit 1
Defrosting request
Unit 2
Defrosting request
30sec.
Reversing

Turns on for
valve

cooling

Cooling output
Heating output
15sec.
Outdoor fan
Defrosting inhibit period Balancing period [TDF414] sec. Reverse cycle period (max. 12 minutes) Balancing period [TDF415] sec. TSKTM1
Defrosting sequence DEFMAX
30sec. TSKTM2 DFSTEPrpm/
Compressor TDFSPT sec. Start sequence
rotation speed
SDRCT2 SDRCT1

480
DFPSMX
Electric expansion valve

Hold 500ms PSTART


Unit 1
DFCTPS
DFSPPS Pulse
Hold DFCTPS
0

480
DFPSMX
Hold 500ms PSTART
Unit 2
DFCTPS
DFSPPS Pulse
Hold DFCTPS
0

● Time chart when executing defrost (Only unit 1 operated, unit 2 stopped)

Defrosting signal
Request Compressor Operation

Unit 1
Unit 2
Unit 1
Unit 2
Unit 1 Defrosting request
Unit 2
30sec.
Reversing

Turns on for
valve

cooling
15sec.
Cooling output
Heating output
Outdoor fan
Defrosting inhibit period Balancing period [TDF414] sec. Reverse cycle period (max. 12 minutes) Balancing period [TDF415]sec. TSKTM1
Defrosting sequence DEFMAX
30sec. TSKTM2 DFSTEPrpm/
Compressor TDFSPT sec. Start sequence
rotation speed
SDRCT2 SDRCT1

480
DFPSMX
Electric expansion valve

Hold 500ms PSTART


Unit 1
DFCTPS
DFSPPS Pulse
Hold DFCTPS
0

480

Unit 2
PCLOSH PCLOSH

– 61 –
AUTO-FRESH DEFROST
● During heating operation is stopped, and when auto-fresh condition is established, defrost operation will be
performed while operation is stopped.
Auto-fresh consists of balancing period at start of defrost for [TDF414] seconds → Reverse cycle period for
MAX 12 minutes.
(1) Start conditions for auto-fresh
● When all the following conditions are established, auto-fresh is executed:
1 Defrost request signal is present.
2 All indoor units are stopped.
3 15 minutes of auto-fresh inhibit period has elapsed.
4 Compressor is ON when operation is stopped.
5 Compressor delay command is sent from indoor unit when operation is stopped.
(2) Release condition of auto-fresh
● If any one of following conditions is established, auto-fresh is released:
1 Heat exchange temperature returns (heat exchange temperature ⭌ DEFOFF)
2 12 minutes of defrost MAX time has elapsed.
3 Failure occurred.
4 Either unit 1 or unit 2 started operation.
❈ Released during start of balancing period: Stopped or started after remaining balancing period has
elapsed.
❈ Released during reverse cycle period : Stopped or started after balancing for 3 minutes.
(3) Outputs during auto-fresh
[Indoor unit defrost request]: Transmitted only to unit to which auto-fresh is applied 9indoor unit stopped
last).
[Compressor]: Accelerated by DFSTEP rpm/TDFSPT seconds and reaches defrost MAX speed [DEFMAX].
[Electric expansion valve]:
Unit auto-fresh not applied: FULL CLOSE when balancing for 30 seconds has elapsed at start of defrost.
Unit auto-fresh applied: Synchronized with step-up of rotation speed of compressor, opened by [pulses
and reaches MAX opening degree [DEFSMX] when rotation speed of compressor
reaches [DEFMAX].
(4) Note
● Shifted to auto-fresh in defrost mode when operation is stopped.
● All indoor units must be stopped to fulfill condition for auto-fresh.
If signal is delayed, auto-fresh condition will not be established.

Defrosting signal
Request Compressor Operation

Unit 1
Unit 2
Unit 1
Unit 2
Unit 1 Defrosting request Balancing request
Unit 2 Balancing request
Reversing

30sec.
Turns on for
valve

cooling
Cooling output
Heating output
15sec.
Outdoor fan
Auto-fresh inhibit period 15min. Balancing period [TDF414] sec. Reverse cycle period (max. 12 minutes) Balancing period 3min.
WMAX2 Defrosting sequence
30sec. TSKTM2 DFSTEPrpm/ DEFMAX
Compressor TDFSPT sec.
WMAX1
rotation speed
SDRCT2

520 80sec.
480
DFPSMX
Electric expansion valve

Hold DFSPPS Pulse


Unit 1
DFCTPS
Hold
0

60sec. 30sec.
520
480
Hold
Unit 2 100rpm
Hold PCLOSH

– 62 –
FORCED COOLING
● In order to accumulate refrigerant, units operate in cooling cycle.
Execution condition and operation status are shown below.
[Execution condition]
● With neither indoor unit 1 and 2 not operated, when forced cooling switch is turned ON, forced cooling will
be performed.
● Always operation status of indoor unit are monitored and forced cooling is inhibited when operation of any
unit is detected.
[Operation status]
● Outdoor unit fan: Fixed in LO.
● Compressor rotation speed: Fixed in 3900min-1.
[Note]
● During forced cooling, if failure occurs in outdoor unit, thermostat is turned off. However, it is not counted.
● Since rotation speed of compressor is fixed in 3900min-1 during forced cooling, compressor fixed speed
control at start is not performed.

The following shows the operation state of forced cooling.


Power
Service switch
Compressor

Unit 1 Forced cooling request Balancing request


Unit 2 Forced cooling request Balancing request
Heating output
Cooling output
Reversing

Turns on
valve

for Heating
Outdoor fan 15sec. + sub
Lo
1sec
Power relay

Operation
1sec
In-rush Prevention
Main microcomputer

1sec
Power 100ms
TSKTM1 Balancing period 3min.
Approx 100ms

Compressor 3900rpm
rotation speed

520 80sec.
31.25PPS [Outdoor temperature<40°C]
480
Electric expansion valve

Unit 1 <TD control + 3N compensation + Diving control>


PSTART

0
Hold 500ms
520
Initialization finished [Outdoor temperature<40°C]
480

Unit 2 <TD control + 3N compensation + Diving control>


PSTART

0
Hold 500ms

❈ ● TSKTM1 and PSTART are EEPROM data.

– 63 –
REFRIGERATING CYCLE DIAGRAM
¿12.7
Cooling, dehumidifying, defrosting

COMPRESSOR
Indoor unit Outdoor unit

¿12.7 SUCTION Service


valve (3/8") Single-ended
TANK union (3/8")
Reversing
valve
¿12.7 ¿9.52 Silencer
¿6.35 ¿9.52
¿12.7
Service
AIR FLOW ¿9.52 valve (3/8") Single-ended
union (3/8")

Silencer
¿9.52
¿6.35

Air
¿6.35 Flow

Electric expansion
valve Service
valve (1/4") Single-ended Air
¿6.35 Flow
union (1/4")
Strainer ¿6.35 Strainer

¿6.35 ¿6.35 ¿6.35


¿12.7
Electric expansion Indoor heat
valve Service exchanger
IN-CASE CONNECTING TO valve (1/4") Single-ended
INDOOR RAS-30CNHZ2 ¿6.35 union (1/4")
1. Fix the Adapter to Service valve Strainer
(¿9.52) as show below.
2. Connect the connecting pipe to
the Adapter.
¿6.35 ¿6.35
Indoor heat
exchanger
INDOOR 2

¿12.7
Service Adapter
valve 10
INDOOR 1

¿12.7 Heating
¿12.7
COMPRESSOR

Indoor unit Outdoor unit

¿12.7 SUCTION Service


valve (3/8") Single-ended
TANK union (3/8")
Reversing
valve
¿12.7 ¿9.52 Silencer
¿6.35 ¿9.52
¿12.7
Service
AIR FLOW ¿9.52 valve (3/8") Single-ended
union (3/8")

Silencer
¿9.52
¿6.35

Air
¿6.35 Flow

Electric expansion
valve Service
valve (1/4") Single-ended Air
¿6.35 Flow
union (1/4")
Strainer ¿6.35 Strainer

¿6.35 ¿6.35 ¿6.35


¿12.7
Electric expansion Indoor heat
valve Service exchanger
valve (1/4") Single-ended
¿6.35 union (1/4")
Strainer

¿6.35 ¿6.35
Indoor heat
exchanger

– 64 –
DESCRIPTION OF MAIN CIRCUIT OPERATION (INDOOR)
MODEL RAS-20CNHZ2, RAS-30CNHZ2
1. Reset Circuit

35V 5V

ZD201

R203
Normal : Hi
Q202 Reset : Lo

R201

R204
10 RES

Q201

R206

C202
+ Micro Computer
R202

C201
AX-7M12

0V

Fig. 1-1

Voltage

35 DC Line
35V

27V
5V DC Line
5V

Base of Q201

POWER ON POWER is OFF


Voltage

5V

Collector of Q202

Fig. 1-2

● The reset circuit initializes the program when power is supplied or power is restored following a power failure.
● RESET “Lo” or SET “Hi” activates the micro computer.
● Fig. 1-2 shows the waveforms in each circuit when power is ON and OFF.
● When power is supplied, the voltages on the 35V and 5V lines rise and when the 35V DC line becomes
approx. 27V, ZD201 turns on and the voltage at the Reset voltage Q201 rises to turn Q201 on.
Since the collector of Q201 goes “Lo” at this time , Q202 turns on and the reset input of the micro computer
goes “Hi”. The 5V DC line has already been 5V at this time and the micro computer starts operation.
● When power is OFF, the voltage on the 35V DC line drops. and when it is approx. 27V, ZD201 turns off, Q201
and Q202 turn off, and the reset input of the micro computer goes “Lo” to reset it.

– 65 –
2. Receive Circuit
Model: RAS-20CNHZ2 R710 12V
R701
R709
+
C701 ZD701

LIGHT 0V 0V
RECEIVING 57 Wireless input
UNIT R705
C702

0V Micro computer
0V AX-7M12
Fig. 2-1

Model: RAS-30CNHZ2 5V

+ R707
C701

LIGHT 0V
RECEIVING 57 Wireless input
UNIT R706 R705
C702

0V Micro computer
0V AX-7M12
Fig. 2-2

● The Light receiving unit receives an infrared signal from the wireless remote control. The receiver amplifies
and shapes the signal and outputs it.

12V
3. Buzzer Circuit
R801

BZ BZ1
Micro computer
AX-7M12

Buzzer output 37 1 16

OV
Fig. 3-1 Buzzer Circuit

● When the buzzer sounds, an approx.


3.9kHz square signal is output from
buzzer output pin U of the micro Metal diaphragm Pizoelectric element
computer. After the amplitude of this
signal has been set to 12Vp-p by a
transistor, it is applied to the buzzer.
The piezoelectric element in the
buzzer oscillates to generate the V V
Sound wave
buzzer’s sound.

Fig. 3-2 Buzzer Operation


– 66 –
4. Auto Sweep Motor Circuit

12V
12V CN4 Auto sweep motor for
horizontal air deflectors

9 1
Micro computer 42 5 12 2
AX-7M12 41 4 13 3 Rotor
40 3 14 4
39 2 15 5
8
IC501

0V

Fig. 4-1 Auto Sweep Motor Circuit (Horizontal air deflectors)

● Fig. 4-1 shows the Auto sweep motor drive circuit; the signals shown in Fig. 4-2 are output from pins
k A
– of the micro computer.

Micro computer pins Horizontal air


Step width
deflectors: 10ms.

Horizontal air deflectors 1 2 3 4 5 6 7 8

42

41

40

39

Fig. 4-2 Micro computer Output Signals

● As the micro computer’s outputs change as shown in Fig. 4-2, the core of the auto sweep motor is excited
to turn the rotor. Table 4-1 shows the rotation angle of horizontal air deflectors.

Table 4-1 Auto sweep Motor Rotation

Rotation angle per step (° ) Time per step (ms)

Horizontal air deflectors 0.0879 10

– 67 –
5. Room Temperature Thermistor Circuit

● Fig. 5-1 shows the room temperature ● The voltage at A depends on the room
thermistor circuit. temperature as shown in Fig. 5-2.

5
5V

Room Micro 4
temperature computer

Voltage at A (V)
thermistor AX-7M12
R309 3
1 Room
temp. input
R310 C301
A 2
0V 0V

Fig. 5-1
1

0
0 10 20 30 40

Room temperature (ßC)


Fig. 5-2

6. Heat exchanger temperature thermistor circuit

5V

Heat exchanger
temperature thermistor Micro computer
AX-7M12
R307
64 Heat
exchanger
R308 C302 temperature
A
input
0V 0V

Fig. 6-1

● The circuit detects the indoor heat


5
exchanger temperature and controls
the following.
4
(1) Preheating.
Voltage at A (V)

(2) Low-temperature defrosting


during cooling and dehumidifying 3
operation.
(3) Detection of the reversing valve 2
non-operation or heat exchanger
temperature thermistor open.
1
The voltage at A depends on the heat
exchanger temperature as shown in
0
Fig. 6-2. -10 0 10 20 30 40

Heat exchanger temperature (ßC)

Fig. 6-2

– 68 –
7. Auto Restart / Temporary Switch

● Auto Restart Switch

MODEL : RAS-20CNHZ2 5V

L501
R704
34 X1
R706
Micro Computer
AUTO RESTART
(AX-7M12)

SW701
NORMAL

Fig. 7-1

MODEL : RAS-30CNHZ2 5V
L501
R601

34 X1
R602
Micro Computer
AUTO RESTART (AX-7M12)
SW2

NORMAL

0V

Fig. 7-2

● Temporary Switch

MODEL : RAS-30CNHZ2
5V

TEMPORARY
SWITCH
C605
SW1

36 HA INPUT
R609
C601

R611

Micro Computer
(AX-7M12)

0V

Fig. 7-3

– 69 –
AUTO RESTART SWITCH
12V

R709 R710
TEMPORARY SWITCH
C701 ZD701
SW701
0V 0V

37 X1

R603
MICRO COMPUTER

0V
Fig. 7-1

● The temporary switch is used to operate the air conditoner temporarily when the wireless remote control
is lost or faulty.
● The air conditioner operates in the previous mode at the previously set temperature. However, when the
power switch is set to OFF, it starts automatic operation.

8. DC Fan Motor Drive Circuit


● Fig. 8-1 shows the indoor DC fan motor drive circuit.

CN10
ICP2 Q901 L901 Red
35V 5
5V
4
R915 R914 R913 D901 R912

Yellow Indoor DC
Q902 3 M Fan Motor
C942 2
R911 Blue
R919

1
C901
D902

+
Micro -
R920

Computer
(AX-7M12)

R916
Fan PWM 54 Q903
R917

Output

PWM 60
Feedback
C933

+
0V
- 5V
R109
R108
R107
R106
R105
R931

0V

Abnormal Fan
59
Current Sensor
R932 R930
D903
C932

+
- Terminal
Board D
0V 0V

Fig. 8-1

● The circuit produces the fan motor drive voltages, 8-33V, from 35V DC supplied from the outdoor unit and
controls the fan motor speed.
● Q903 is switched on and off according to the signal at fan PWM output pin F to control the voltage which
is smoothed by D901, L901 and C901 to drive the fan motor.
● The output voltage is divided by R919 and R920 and is input to divided voltage output pin ; the micro :
computer controls the fan PWM output so the output voltage is set to the specified value. The chopper
frequency of the fan PWM output is 15.7kHz.
● In the Fan current detection circuit, 35V line current is detected by R105 ~ R109 and input to abnormal
L
fan current sensor pin . Microcomputer detects overcurrent comparing it with the current judgment value
corresponding to the fan rotation speed.

– 70 –
DESCRIPTION OF MAIN CIRCUIT OPERATION (OUTDOOR)
Model RAM-50CNHZ2
1. Power Circuit

POWER P.W.B.
YEL

BLU

SWITCHING POWER P.W.B.


(FOR INDOOR AND OUTDOOR
P.W.B.)

SWITCHING POWER P.W.B.


(FOR INDOOR P.W.B.)
Fig. 1-1

● This circuit full-wave rectifies 220-230V AC applied between terminals L and N, and boosts it to a required
voltage with the active module, to create a DC voltage.

The voltage becomes 260-380V when the compressor is operated

< Reference >


(1) System power module (SPM2) ● In case of malfunction or defective connection:
(Surrent ACT module, smoothing capacitors Immediately after the compressor starts, it may stop
and power module are combined into one due to “abnormally low speed” active error, etc.
unit)
1
The compressor may continue to operate normally,
Active module but the power-factor will decrease, the operation
The active filter, consisting of a reactor current will increase, and the overcurrent breaker
and switching element, eliminates higher of the household power board will probably activate.
harmonic components contained in the
● In case of active module faulty or defective contact:
current generated when the compressor
is operated, and improves the power- Although the compressor continues to operate
factor. normally, the power-factor will decrease, the
Smoothing capacitor smoothes voltage, operation current will increase, and the overcurrent
which has been rectified by diode stack breaker of the household power board will probably
and boosted at ACT section. activate.
2 Power module section < Reference >
Refer to item 3 System Power Module ● If diode bridge 1 is faulty, the compressor may stop
Circuit. due to “lp”, “abormally low speed”, etc. immediately
after it starts, or it may not operate at all because
(2) Diode stacks no DC voltage is generated between the positive e
These rectify the 220-230V AC from and negative d terminals.
terminals L and N to a DC power supply. If diode bridge (D25VB60) is faulty, be aware that
the 25A fuse might also have blown.
● If diode bridge (DS) is faulty, DC voltage may be
not generated and the compressor may not operate
at all. Also, be aware that the 3A fuse might have
blown.

– 71 –
(3) Smoothing capacitor C501,C52,C503
This smoothes (averages) the voltage rectified by the diode stacks.

L +
b + + + Vd (DC Voltage)
a
– – –
C501 C502 C503
N –
Fig. 1-2

a OV

b OV

Vd
DC Voltage
Fig. 1-3
(Approx. 330 or 360V during operation)

Smoothing capacitor
(C501, C502, C503)
SPM2

GRN3

GRN1

Terminal
Power P.W.B Board (2p)
Control P.W.B
Reactor Diode Stack Switching Power P.W.B Service-switch
(D25 VB60) (For Indoor P.W.B.)
● Be careful to avoid an electric shock as a
high voltage is generated. Also take care
not to cause a short-circuit through incorrect
connection of test equipment terminals. The
circuit board could be damaged.
(4) Smoothing capacitor (C020, C021)
This smoothes (averages) the voltage rectified by the diode stacks.
A DC voltage is generated in the same way as in Fig. 1-3. Voltage between 丣 side of C020 and 両 side
of C021 is about 330V.

– 72 –
(5) C001 to C005, NF COIL 1 ❈ Be sure to ground outdoor unit.
There absorb electrical noise generated during If not grounded, noise filter circuit does not operate
operation of compressor, and also absorb external correctly.
noise entering from power line to protect eletronic
parts.
(6) Sugar absorber, varistor 1,2,3 ❈ If outdoor unit is not grounded, “sugar absorber”,
These absorbs external power surge. “varistors 1 and 3” do not operate.
Be sure to perform grounding.
(7) Inrush protective resistor (R002, R003)
This works to protect from overcurrent when power
is turned on.

<Reference>
When inrush protective resistor is defective, diode
stack may malfunction. As a result, DC voltage is not
generated and no operation can be done. In this case,
3A fuse may have been blown.

2. Indoor/Outdoor Interface Circuit

● The interface circuit superimposes an interface signal on the 35V DC line supplied from the outdoor unit to
perform communications between indoor and outdoor units. This circuit consists of a transmiting circuit which
superimposes an interface signal transmit from the micro computer on the 35V DC line and a transmiting circuit
which detects the interface signal on the 35V DC line and outputs it to the micro computer.
● Communications are performed by mutually transmiting and receiving the 4-frame outdoor request signal one
frame of which consists of a leader of approx. 100 ms., start bit, 8-bit data and stop bit and the command signal
with the same format transmit from the indoor unit.
● From outdoor microcomputer to indoor microcomputer
The request signal output from microcomputer pins X
is input to the transmitting circuit. The transmitting circuit
!
outputs an approx. 38kHz high-frequency signal via pin and continues the output intermittently according to
the request signal. This high-frequency signal is amplified by a transistor, superimposed on the DC 35V line
via C801, C811 and L801, L802 and supplied to the indoor unit.
To prevent erroneous reception, the outdoor microcomputer is designed so that it cannot receive a signal while
it is outputting a request signal,
The receiving circuit in the indoor unit consists of a comparator and transistor. The interface signal from the
outdoor unit on the DC 35V line is supplied to C821, where DC components are eliminated, and is then shaped
by the comparator. The shaped signal is detected by diode, amplified by amp, and supplied to receiving k
input of the indoor microcomputer.
Fig. 2-2 shows the voltages at each component when data is trnsferred from the outdoor microcomputer to
the indoor microcomputer.
● Indoor micro computer to outdoor micro computer
The communications from the indoor micro computer to the outdoor micro computer are the same. Fig. 2-3
shows the voltages and waveforms at each circuit.

– 73 –
● Fig. 2-1 shows the interface circuit used for the indoor and outdoor micro computers to communicate with
each other.

MAIN P.W.B.

IF RECEIVE
(SD1)

MICRO
COMPUTER
(AX-7M12)

IF TRANSMIT
(SD0)

INDOOR P.W.B.

OUTDOOR P.W.B.
POWER P.W.B.

MAIN P.W.B.

IF CLOCK

MICRO
COMPUTER
(AX-6M00)
IF TRANSMIT
(SD01)

IF RECEIVE
(SDI1)

(Communications from indoor micro computer to outdoor microcomputer)

(Communications from outdoor micro computer to indoor microcomputer)

Fig. 2-1 Indoor / outdoor interface Circuit

– 74 –
0.7V
Base of outdoor P.W.B. Q801, Q802 0V

Outdoor micro computer pin 70 , 72 5V


0V

Indoor micro computer pin 49 5V


0V
Pin 48 5V
0V

35V DC line 35V

100ms. 33ms.
Leader 1 frame

Fig. 2-2 Voltages Waveforms of indoor / Outdoor Micro computers (Outdoor to Indoor Communications)

Base of outdoor P.W.B. Q801, Q802 0V

Outdoor micro computer pin 69 , 71 5V


0V

Indoor micro computer pin 49 5V


0V
Pin 48 5V
0V

35V DC line 35V

5~7.5ms. 33ms.
Transmit / receive 1 frame
switching time

Fig. 2-3 Voltages Waveforms of indoor / Outdoor Micro computers (Indoor to Outdoor Communications)

– 75 –
● Fig. 3-1 shows the system power module and its peripheral circuit. (Current ACT module and power module are combined into one unit.)
The three transistors on the positive e side are called the upper arm, and the three transistors on the negative d side, the lower arm.

System Power module 2

Coil 0.35mH
Power relay
FUSE (25A) +
L DC
Compressor
motor
R003
3. System Power Module Circuit

+ + + A U coil
R002 Inrush current U V W
protection U
relay
V
+ + +
R004 W
C006 – – –

– 76 –
V coil

W coil
U– V – W–


N
Noise filter R24
Terminal
coil
board

ACT MODULE INVERTER

Fig. 3-1 System power module circuit (U+ is ON, V– is ON)


● DC 260-360V is input to power module and power module switches power supply current according to
rotation position of magnet rotor. The switching order is as shown in Fig. 3-2.

[At point E: U+ is ON, V– is ON (circuit in Fig. 3-1)


]
At point F: U+ is chopped (OFF), V– is ON (circuit in Fig. 3-4)
E F

V+ W+ U+ V+

Upper arm
transistor

Lower arm Time


transistor

U – V – W–
T

Fig. 3-2 Switching order of power module

● Upper arm transistor is controlled to ON/OFF by 3.2kHz chopper signal. Rotation speed of the compress
is proportional to duty ratio (ON time/ ON time + OFF time) of this chopper signal.
● Time T in Fig. 3-2 shows the switching period, and relation with rotation speed (N) of the compressor is
shown by formula below;
N = 60/2 X 1/T
● Fig. 3-3 shows voltage/current waveform at each point shown in Figs. 3-1 and 3-4. First half of upper arm
is chopper, second half is ON, and first half of lower arm is chopper, second half is ON.

+ -
U transistor chopped U transistor ON
Voltage point A

260V-360V

Chopping period
T

Chopping period

ON
Upper arm transistor

Current at B

Fig. 3-3 Voltage waveform at each point

● When power is supplied U+ [ U–, because of that U+ is chopped, current flows as shown below; B
(1) When U+ transistor is ON: U+ transistor [ U coil [ V coil [ V– transistor [ DC current detection
resistor [ Point B (Fig. 3-1)
(2) When U+ transistor is OFF: (by inductance of motor coil) U coil [ V coil [ V– transistor [ Return
diode [ Point A (Fig. 3-4)

– 77 –
260V-360V System power module

DC compressor
A U coil motor
U+ V+ W+
U
V
W

B U– V– W–
V coil

W coil

DC current (Id)
detection resistor

Fig. 3-4 System power module circuit (U+ is ON, V– is ON)

● Since current flows at point B only when U+ transistor is ON, the current waveform at point B becomes
intermittent waveform as shown in Fig. 3-3. Since current at point B is approximately proportional to the
input current of the air conditioner, input current is controlled by using DC current (Id) detection resistor.

<Reference>
If power module is detective, self diagnosis lamps on the control P.W.B. may indicate as shown below:

Smoothing capacitor Table 3-1


(C501, C502, C503)
SPM2
Self-diagnosis lamp
Self-diagnosis
and mode

lp (peak current cut) Blinks 2


LD301
times

Abnormal low speed


GRN3

GRN1
Blinks 3
rotation LD301
times
Terminal
Power P.W.B
Control P.W.B Board (2p)
Reactor
Switching incomplete Blinks 4
Diode Stack Switching Power P.W.B Service-switch LD301
(D25 VB60) (For Indoor P.W.B.) times
Self-disgnosis lamps
(From left: LD301, LD302, LD303, LD304)

❈ From results of power module simple inspection (inspection mode when operated with compressor lead
disconnected), LD310 blinks four times about 2 seconds later: Unit has not entered the normal operation.

– 78 –
4. Power Circuit for P.W.B.

● Fig. 4-1 shows the power circuit for P.W.B.

Switching transformer 17V


R717 D713
16
C718 R712
17
Diode stack R718 D710 115V
1
18
R005 R702 R701 R703 C714 C707 R714
19
CO20

12V 5V
R010

C735
D709
13 P.EG1
9 D705
CO21

R011

C708 C721 C716

IC1 14

C709
3 4 D702 R708
12 R723 D706 OV
15

D703
C731 -5V
1
2 5 20
C723
C722

C734 C740
FB1
D716

11
R722 21

R713
C710
D715 R724 D707
R716

R715
C733 22
C822
C732 R710
4 1 R711
C725 1
R726 2 2

REG2
3 PQB
D708
C724
3
R725

Fig. 4-1 Power circuit for P.W.B.

● In the power circuit for P.W.B., power voltage for microcomputer, peripheral circuits, and system power
module drive and, as well as DC35V, are produced by switching power circuit.
● Switching power circuit performs voltage conversion effectively by switching transistor IC1 to convert
DC330V voltage to high frequency of about 20kHz to 200kHz.
● Transistor IC1 operates as follows:

(1) Shifting from OFF to ON


● DC about 330V is applied from smoothing capacitors C020 Œ andC021 œ in the control power circuit. With
this power, current flows to pin 4
of IC1 via R701 and R702 and IC1 starts to tum ON. Since voltage in
the direction of arrow generates at pin @
of Switching Transforwer at the same time, current passing
through R708 and D702 is positive-fed back to IC1.

– 79 –
(2) During ON
● The drain current at IC1 increases linearly. During this period, the gate voltage and current become
constant because of the saturation characteristics of the transformer.
(3) Shifting from ON to OFF
● This circuit applies a negative feedback signal from the 12V output. When the voltage across C708
reaches the specified value, REG2 turns on and current flows to PQ8 1-2. This turns the secondary
circuits on, sets IC1 pin 1 to “Hi”, and turns IC1 off.
(4) During OFF
● While IC1 is on, the following energy charges the primary windings of the transformer:

Energy=LI2/2. Here, L : Primary inductance


I : Current when IC1 is off
This energy discharges to the secondary windings during power off. That is, C707-C710, C718 is charged
according to the turn ratio of each winding.
● At the start, an overcurrent flows to IC1 because of the charged current at C707-C710, C718.

● The drain current at IC1 generates a voltage across R716. If it exceeds the IC1 base voltage, it sets the
IC gate voltage to “HI”.
● R716 limits the gate voltage to prevent excessive collector current from flowing to IC1.

● This SW power circuit uses a frequency as low as 20kHz, especially at a low load (when both the indoor
and outdoor units stop): This reduces power loss in standby status.

<Reference>
If the power circuit for P.W.B. seems to be faulty:

(1) Make sure that 5V, 12V, 15V, 17V and -5V on the control P.W.B. power voltage are the specified values.
(2) When only the 5V output is low:
REG 1 (regulator) faulty, 5V-0V shorted, output is too high, or REG 1 is abnormal.
(3) When 12V and 5V are abnormal:
The following defects can be considered:
1 Fan, operation, power, rush prevention relay (shorting in relay, etc.)
2 REG 1 (regulator is abnormal), etc.
Shorting on primary circuits.
When shorting occurs in the secondary circuits, there is no abnormality in the primary circuits because
of overcurrent protection.
The voltage rises when an opening occurs in the primary circuits, or the feedback system is abnormal.
(4) When 15V/17V power supply is abnormal:
D710, D713 or drive circuit is abnormal.
(5) When all voltage are abnormal:
IC1, R716, may possibly be defective. Also D cable may possibly be reverse connected.
❈ If IC1 is abnormal, be aware that other components, such as the power module, REG (regulator), etc.
are possibly defective.

[When the switching power supply seems to be abnormal, the voltage between IC1 pin 4 (to be measured
at the leads of R202 and R201) and IC1 pin 5 (to be measured at R216 lead) may be between 11 and 16V.
This is because the protection circuit of IC1 is operating.]

– 80 –
5. Reversing valve control circuit

35V

12V
Reversing
valve CN2
3

D831
PQ831

Q831 Micro
Computer
R832 R833
24

R831
DC voltmeter V
or tester

IC8

0V

Fig. 5 1

● By reversing valve control circuit you can switch reversing valve ON/OFF (Heating ON) according to instruction
from indoor microcomputer and depending on operation condition.
Voltage at each point in each operation condition is approximately as shown below when measured by tester.
(When collector voltage of Q831 is measured)

Table 5-1

Operation condition Collector voltage of Q831

Cooling General operation of Cooling About 35V


In normal heating operation About 0.8V
MAX. rotation speed instructed
Heating by indoor microcomputer after About 0.8V
defrost is completed
Defrosting About 35V
Dehumidifying Sensor dry About 35V

– 81 –
6. Rotor magnetic pole position detection circuit

Inverter
DC brushless motor
for compressor

+ + + R502

R501

R500

+
R253

W V U
C205 +5V
+12V
R505 R504 R503

OV
Microcomputer of outdoor unit

R604 B
59 R601 R602 R603
3 A
C R605
+ 7
18 1
6
C605 D R606
OV + 5
19 2
4
C606 E R607
OV + 11
20 13
C607 10 R611 R610 R609
+ 9 R608
OV 14
8
C604
C603
C602
C601

12
IC3 OV

OV

Fig. 6-1 Rotor magnetic pole position detection circuit

When the DC brushless motor is rotated, it also operates as power generator, generating reverse electromotive
force according to number of rotations. This reverse electromotive force is voltage-divided by R503-R505 and
R604-R011, and appears as point A voltage. IC3 compares and digitalizes point A voltage with point B voltage
(in which DC voltage (Vd) is voltage-divided by R501, R502 and R608), and inputs this to microcomputer as
position detection signals for points C, D and E. Microcomputer switches inverter using optimum timing based
on position detection signals, in order to control the rotation of the brushless motor.

– 82 –
7. Peripheral circuits of microcomputer

● Fig. 7-1 shows the microcomputer and its peripheral circuits.


Table 7-1, the basic operations of each circuit block and Fig. 7-2, the system configuration.

12V +5V

ZD201

R290
R292
Q208 Outdoor
Microcomputer
R291 Q209

C223
R293
(AX-6L02)

R294
C224
48 RESET

R295
C222
SPM
terminal 0V

0V 0V 0V
DC current

Detection
resistor
R24 12V
5V
0V R245
+
8 IC4
– 5 +
+ 7
C220 6 –
– 4 9 IP cutter
SPM
R247

R249 terminal

0V 0V R248
60 Id
Is 5V
C281
0V
D205
D104 R110 R278 R222
+
61 Is
R108 – C105 R221 C221
0V 0V 0V

Fig. 7-1 Peripheral circuit of microcomputer (AX-6M00)

Table 7-1

Circuit block Basic operation

This circuit detects DC current flowing to power module: When over-current


Peak current
(instantaneous value) flows, it stops upper and lower arm drive circuits and also
cut off circuit
produces lp signal to stop microcomputer.

Overload external This circuit detects DC current flowing to power module and produces signal to
judgment circuit notify microcomputer of overload status.

This circuit voltage-amplifies DC cuccrent level detected by detection resistor and


Voltage amplifier
sends it to microcomputer. In addition, setting of internal/external overload
circuit
judgment is performed.

Reset circuit This circuit produces reset voltage.

– 83 –
5V

Reset Voltage

synthesis circuit
Reset circuit

Trip signal
Chopper Chopper Drive
signal signal Drive signal

Outdoor microcomputer
Circuit Compressor
Overload external
motor
judgement circuit
DC330V
or 360V Inverter
section
IP signal
DC Peak current
Current cut off circuit
level
Current amplified
circuit AX-6M00

Detection
resistor
DC current

Fig. 7-2

● The following gives details of operation for each circuit:

7-1. Peak current cut off circuit


Fig.7-3 shows peak current cut off circuit and waveforms at each point.

SPM Control P.W.B.

Negative — B
Terminal
DC current Id HIC CN14
27A DC current
20 9 2 9
R42 IP cutter
A IC1
8 Outdoor
F microcomputer
R41
9 9 OC
Voltage at point A
R43 C43
1.35V

Detection 0V 0V
resistor R24

Voltage at point B

0V

Fig.7-3

● Ip cut circuit detects instantaneous surge current and stops inverter to protect components such as SPM.
● As shown in diagram, when current exceeding 24A flows, voltage at point A detected by detection
resistor is input to pin 9 of INV-HIC, and voltage divided by R41 and R43 is input to pin 9 of IC1. Since
this voltage exceeds threshold of IC1, LO is output from pin 8 (voltage at point B). When LO is input
to pin 9
of microcomputer, microcomputer stops drive output.
● When drive output of microcomputer stops, all drive outputs are set to HI, and IC1 of HIC is initialized
to enter drive signal waiting status. Microcomputer again outputs drive signal 3 minutes later to re-start
operation.

– 84 –
8. Overload control circuit (OVL control)
● Overload control decelerates speed of compressor reducing load when the load to protect compressor,
electronics parts and power breaker, when operation enters overload status due to increase of load for
room temperature adjustment.
● To judge overload, DC current and set value are compared.
● Fig. 8-1 shows the overload control system configuration and Fig. 8-2 shows characteristic diagram of
overload judgement values. There are two judgements. One is external judgment: External set value and
DC current value are compared for judgment regardless of rotation speed. The other is internal judgment:
set value varying according to rotation speed programmed in microcomputer is compared with DC current
value for judgment.

AX-6M00 microcomputer
To pin of
power module (E2PROM built-in)
DC current OVL judgment
to external set
Motor control
value
process

Rotation speed data


Detection
resistor
OVL judgment
Voltage amplifier A/D according to
circuit converter rotation speed

(Internal judgement)

Data selection
DC voltage A/D according to rotation
converter speed/DC voltage

OVL start current data

Fig. 8-1 Overload Control System Configuration


DC current

Judgement value according to the rotation speed


(internal judgement value)

Rotation speed

Fig. 8-2

(1) Overload external judgement circuit

● Voltage generated from current flowing in shunt R is balanced by R245 and C220 and input to pin of 5
IC4. Then voltage-amplified value is input to pin :
of microcomputer to compare with internal data of
EEPROM. When values correspond, microcomputer enters overload control.
● Fig. 8-4 shows the rotation speed control. When value at pin :
of microcomputer exceeds set value,
rotation speed of compressor decelerates to reduce load regardless of rotation speed commanded from
indoor unit.

– 85 –
(330V or 360V)
Detection resister DC current

R500

59 Vd
R245 R253 C205
5V Microcomputer
(AX-6M00)
36 0V 0V
IC4 D204
+
C220 – 6 –
+ 7 60 Id
5

R249
Is R247 5V

0V D205
D104 R110 R278 R222
61 Is
+
C103 R108 – C105 R221 C221
0V 0V 0V
0V 0V
HIC

Fig. 8-3

Voltage at point 60
of microcomputer

Rotation speed Commanded rotation speed


of compressor
Actual rotation speed

Deceleration Acceleration Deceleration Acceleration

Fig. 8-4

(2) Voltage amplifier circuit


● Voltage amplifier circuit voltage-amplified DC current level detected by converting to voltage using detection
resistor and sends this to microcomputer. Microcomputer A/D-converts it and then compares with internal
data to judge over-load control.

[During overload control]


● Voltage generated from DC current flowing to detection resistor is balanced by resisitor R245 and C220,
then input to pin 5
of IC4. IC4 composes non-inverting amplifies, combined with peripheral components.
● As shown in Fig. 8-5, a value varying according to rotation speed is programmed in microcomputer: When
DC current value exceeds this set value, overload control is set. Control of compressor motor is the same
as that in external judgment.
● Set value is determined by amplification rate of voltage amplifier circuit programmed by software.

Amplification rate: High [ DC current : Low


Amplification rate: Low [ DC current: High

– 86 –
● R500 and R253 detect DC current in current circuit. Microcomputer compensates for overload set value
so that the following is obtained:
DC voltage: High → DC current: Low
{ DC voltage: Low → DC current: High
(Since load level is expressed by DC voltage x DC current, this is intended to perform the same load
judgment even when voltage varies.)
Amplification rate : low
DC voltage : low
DC current : high

Amplification rate : x 7.3


DC voltage : 230V
DC current

Amplification rate : high


DC voltage : high
DC current : low

0
0 Rotation speed

Fig. 8-5

[When starting current control]


● It is necessary to keep starting current (DC current) fixed to ensure smooth starting of DC motor for
compressor.
● For RAM-50CNHZ2, starting current control is performed by software.

● Starting current will change reflect to change in power voltage. The control system deals with change in
voltage as shown below.
(1) As shown in Fig. 8-6, U+ and V- transistors on power module are turned on to apply current to winding
of motor.
(2) As shown in Fig. 8-7, ON time of W+ transistor changes according to DC voltage level so that starting
current is about 10A.

System power module


DC current
Compressor motor
U+ V+ W+

U
V
DC 360V W
U— V— W—

Detection
resistor

Fig. 8-6

Chopper duty: large


W transistor

DC voltage: low
ON-time

DC voltage: 360V
DC voltage: high

DC current (starting current)


DC current (A)

10.0 Set value


7.5
5.0
2.5
Time
Start

Fig. 8-7

– 87 –
9. Reset Circuit

12V +5V

R292 ZD201
Micro

R290
computer
AX-6M00
Q208
R291 Q209

C223
R293
R294
C224

48 RES
R295
C222

0V

0V 0V 0V

Fig. 9-1

● Reset circuit performs initial setting of microcomputer program when power is turned on.
● Microcomputer resets program with reset voltage set to Lo, to enable operation at Hi level.
● Fig. 9-1 shows the reset circuit, and Fig. 9-2 shows waveforms at each point when power is turned on/
off.
● After power is turned on, 12V line and 5V line voltages rise: When 12V line voltage reaches 7.2V (Zener
voltage of ZD201), ZD201 turns ON and Q208 and Q209 turn on, and reset voltage becomes Hi. Reset
voltage is not set to Hi until VDD of microcomputer rises to 5V, enabling operation, due to ZD201.
● After power turns off, when 12V line voltage drops, ZD201 also turns OFF. However, Q208 is left ON since
reset voltage is fed back by R294, until 12V line drops to about 7.6V. This prevents chattering of reset
voltage due to voltage chnge in 12V line.
Voltage when power is turned ON

12V line
12

6 5V line

Reset voltage

0
Time
Voltage when power is turned OFF

12V line
12

6 5V line

Reset voltage

0
Time
Fig. 9-2

– 88 –
10. Temperature Detection Circuit
HIC
+5V
O.H. thermistor
Normal: 2.7V or less
OH: 2.7V or more
R304 Return: 2.3V or less
62 O.H.
CN5
R301 C301
+5V Microcomputer
DEF thermistor 0V (AX-6M00)
0V Normal: 2.4V or more
OH: 2.4V or less
R305 Return: 2.9V or more
63 DEF.
CN6
R302 C302
Outdoor temperature +5V
thermistor 0V
0V
R306 Refer to Table 10-1
64 Outdoor
CN7 temperature
R303 C303
0V
0V

Fig. 10-1

● Compressor head surface temperature is detected by OH thermistor circuit, defrost operation temperature
is detected by DEF thermistor circuit, and outdoor temperature is detected by outdoor temperature thermistor
circuit.
● Thermistor is a negative resistance element with the following characteristic: Resistance falls when
temperature rises, and increases when temperature falls.
● When compressor is over-heated, resistance of OH thermistor decreases and voltage at pin of x
microcomputer rises.
● Voltage at pin x of microcomputer is compared with set value stored inside: If voltage exceeds set value,
microcomputer judges over-heating and stops operation.
● If outdoor heat exchanger is frosted, heat exchanger temperature will rapidly drop. In response, resistance
of DEF thermistor increases and voltage at pin c
of microcomputer falls. When the voltage flls under the
set value, microcomputr enters defrost control mode.
● During defrost operation, microcomputer transfers indoor unit defrost condition command from IF transmision
output at SDO pin of interface (pin / and Xof microcomputer).
● Outdoor temperature is always read in (voltage at pin v
of microcomputer) by outdoor temperature
thermistor, and then transferred to indoor unit side. According to this value, compressor rotation speed
control and operation selection (outdoor fan ON/OFF, etc.) in dehumidifying mode are performed.
Represented values of the relationship between outdoor temperature and voltage are shown below.

Table 10-1

Outdoor temperature (°C) -10 0 10 20 30 40

Voltage at pin 1 of CN7 (V) 1.19 1.69 2.23 2.75 3.22 3.62

(Reference)
When thermistor is open or heat is shut off, pins x v
to of microcomputer are set to about 0 V; when
thermistor is short-circuited, pins x v
to of microcomputer are set to about 5V, and LD301 blinks 7 times.
However, OH thermistor detects only short-circuit as error: It will enter a blink mode after 12 minutes or more
has elapsed from the start of compressor operation.

– 89 –
● Fig11-2, 0 to 5V chopper signal is output from microcomputer for each phase. The signal output from microcomputer is input to IC, inverted
due to active LO, and 0 to 15V chopper signal is obtained. This signal is then applied to transistor gate of each phase to drive.
11.Drive circuit
Fig. 11-1 shows the drive circuit.

PWB (MAIN)
phase have the same Configuration.

B B B
The circuits for U phase, V phase and W

COMPRESSOR MOTOR

– 90 –
AX-6M00 IP CUTTER Id CONTROL CIRCUIT
GRY

Fig. 11-1
MICRO COMPUTER A
120° 120° 120° 120° 120°
+ + + + +
U V W U V
V W U V W

Drive signal at point A


U + 5V
0V
V+
W+

U
V
W

U + 15V
0V

V+
Drive signal at point B

W+

Fig. 11-2

– 91 –
12. Electric expansion valve

12V 12V 5V
R208

CN15, 16 C225 16 9 1 8
R209 IC6, 7 Microcomputer
6 2 3 39 Valve A

5 15 14 40 Valve B
4
7 6 41 Valve A
3
2 10 11 42 Valve B

1 4 5 12 13
Electric expansion valve 1

OV

Fig. 12-1

● The electric expansion valve is driven by DC 12V. Power is supplied to 1 or 2 phase winding to switch
magnetic pole of winding in order to control opening degree.
● Relationship between power switching direction of phase and open/close direction is shown below.
When power is supplied, voltages at pins to 4 1
of CN 15 and CN 16 are about 0.9V; they are about 12V
when no power is supplied. When power is reset, initialization is performed for 10 or 20 seconds.
During initialization, measure all voltages at pins to 4 1
of CN15 and CN16 using tester. If there is any pin
with voltage that has not changed from around 0.9V or 12V, expansion valve or microcomputer is defective.
● Fig 12-2 shows logic waveform when expansion valve is operating.

Table 12-1
Pin Lear Drive status
phase No. wire 1 2 3 4 5 6 7 8
4 White ON ON OFF OFF OFF OFF OFF ON
3 Yellow OFF ON ON ON OFF OFF OFF OFF
2 Orange OFF OFF OFF ON ON ON OFF OFF
1 Blue OFF OFF OFF OFF OFF ON ON ON

Operation mode
1 2 3 4 5 6 7 8 VALVE CLOSE
8 7 6 5 4 3 2 1 VALVE OPEN

12V
Pin No. 42, 38
0.9V

41, 37

40, 36

39, 35

50ms 75ms

200ms

Fig. 12-2

With explosion valve control, opening degree is adjusted to stabilize target temperature, by detecting temperature
of compressor head.
The period of control is about once per 20 seconds, and output a few pulses.

– 92 –
Outdoor DC Fan Motor control circuit

DC330~360V
PWB (POWER)
METAL COVER SPM2

RC FILTER

MOTOR COIL
1

ONE CHIP DRIVER IC


2
3 0V
4 Vcc
5 PWM control VSP
voltage
6
FG Pulse
7 BOARD

PWB (MAIN)
FAN LIMITER

MICROCOMPUTER
AX-6M00

FAN CHOP

FM 60˚el

● This model uses DC Fan Motor which is including controller circuit into the Motor shell.
● This DC Fan Motor will rotate by control voltage apply to Vsp input. (Voltage range: 1.7 to 7V DC)
Vsp high : Faster ; Vsp low : slower ; Vsp lower than 1.7V : stop
● Motor will output FG pulse by following this motor revolution.
● Outdoor Microprocessor will output PWM control signal from FAN CHOP terminal by following the instruction
from indoor Microprocessor.
● This PWM control signal will convert to Vsp voltage by smoothing circuit (Q101 & RC filter)
● Fan motor will start to rotate when Vsp was proceeding over than 1.7V, and generate FG pulse by rotation
speed.
● FG pulse will feed back to Outdoor Microprocessor through PQ102.
● PQ102 is the isolator between Microprocessor circuit and DC Fan Motor circuit, which has to match the Fan
Motor revolution with instructed revolution. Such as...
FG feedback: Faster – Instruction: Slower ... Decrease pulse width
FG feedback: Slower – Instruction: Faster ... Increase pulse width
● FG pulse is also used for Fan Motor fail detection
● Microprocessor will monitor FG pulse 30 seconds after start the fan motor. If there is no signal detected, it
will consider that the Fan Motor was malfunction and stop the operation. In this case, LD301 on control PWB
will blink 12 times. (Fan Motor lock detected)
● R107 and IC4 are used for Fan Motor over current detection.

– 93 –
<Reference>
● When stop operation with LD301 blinks 12 times, it may be a DC Fan Motor broken.
● In this case, please check CN30 and CN31 connection first. It makes Fan Motor Lock also it those
connectors are in misconnection.
● If 2A Fuse was burned it is possible that the DC Fan Motor may be damaged too.
● DC Fan Motor has broken when 2A Fuse was burned. Please replase both DC Fan Motor and 2A Fuse
together.
● Fan lock detecting system may be actidiated when something has disturb the Fan rotation by inserting
materials into propeller fan or ice has growing inside of outdoor unit by snowing.
● Fan lock detecting system may be actidiated by strong wind (ex. 17m/sec or above) against the Fan
rotation. In this case, unit will be restart again after a while.
● Fan lock detecting system may be actidiated even though the DC Fan Motor is rotating correctly, the
possible casue is due to Motor problem or PQ102 on board or control board problem.

<Caution>
● Please take precaution while servicing Fan Motor circuit, because it carries DC330~360V supply.
● It is impossible to troubleshoot the Fan Motor bacause its circuit is integrated and conceal in the Fan
Motor.

– 94 –
[Air conditioner not operated/not operated correctly]

Is 220-240V supplied to L,N


terminal?

Yes If fuse is blown, other parts may be


affected. Take care.
No (Mainly, varistor 2, diode stack,
Is 25A fuse normal? smoothing capacitor, and system
TROUBLE SHOOTING

power module.)
MODEL RAM-50CNHZ2

Replace defective components.

Is power circuit normal? No


Refer to item of power circuit
Check to see whether the
for details.
connected cord D cable correctly?
If reversed, correct the cable
Yes No connection.
No Yes
Is switching power circuit OK? Replace defective components.
Is the 5V supplied between

– 95 –
Is 3A fuse normal?
Pin 4 (test pin) and pin 5
(5V) of CN18? If 3A fuse is blown, switching
transformer, could be
( defective. )
Yes

Operate outdoor unit


according to instructions on
“How to operate outdoor unit
CHECKING THE OUTDOOR UNIT ELECTRICAL PARTS

independently”.

How is self-diagnosis lamp Refer to lighting mode of self-


(LD301) lighting? diagnosis lamps.
Yes Is DC voltage of about 35V
No
LD304 blinks once. being output to C, D terminals?
Communication error. (DC33v~38.5V is output
normally.)
C,D
No Yes (Inddor 2)
Which is Switching power circuit for indoor 2
broken, C,D (Indoor 1) Or C,D P.W.B. could be defective.
(Indoor 2)

C,D (Inddor 1)

No
Is voltage of about 35V being output D707 and C710 could be defective.
to both ends of R713?

Yes

– 96 –
No There may be defective parts between
Is DC 12V being applied to both 12V output of switching power supply on
ends of control side (coil terminals) control P.W.B. and interface relay. (Also
Interface relay
of interface relay? be care of solder-touch, etc.)

Yes
Coil terminal
Is voltage (10V or more) being Yes
Contact terminal generated between contact Repalce interface relay.
terminals of interface relay?

No

Check interface curcuit.


Yes No
LD301 blinks 8 times. Is system power module (SPM2)
Replace system power
normal? module. (SPM2)
Acceleration error
Yes
No
No
Looking at P.W.B. diagram and
Is drive circuit normal? Replace defective parts. circuit diagram, perform continuity
check of pattern and lead wire.

Yes Yes
Is thermistor connected correctly?
LD301 blinks 7 times.

– 97 –
Connect thermistor.
Thermistor abnormal. ❈ Be careful not to forget to connect
it after servicing is completed.
No

No

No

Is continuity of thermistor normal? Replace thermistor.

Yes

No
Looking at P.W.B. diagram and
Is thermistor circuit normal? Replace thermistor circuit circuit diagram, perform continuity
parts.
check of pattern and lead wire.
LD301 blinks 6 times. Yes
No
Replace thermistor circuit
OH thermistor temperature Is thermistor circuit normal?
parts.
rises.
No

Yes
No
LD301 blinks 5 times. Is system power module Replace system power
Over-load lower limit cut. (SPM2) normal? module? (SPM2)

No
Yes

Replace main P.W.B.

– 98 –
Yes
LD301 blinks 4 times. No
Is system power module Replace system power
Switching Failure. normal? (SPM2) module. (SPM2)
No
Yes

Looking at P.W.B. diagram and


Is drive circuit normal? Replace defective parts. circuit diagram, perform continuity
check of pattern and lead wire.
LD301 blinks 3 times.
Abnormal low speed.
Yes No
LD301 blinks twice. Is system power module Replace system power
Peak current cut. normal? (SPM2) module. (SPM2)

No
Yes

No

Is drive circuit normal? Replace defective parts.

– 99 –
No

LD301 blinks once. Replace defective parts.


Is reset circuit normal?
Reset stop.

However, reset stop is always


displayed immediately after power is )
( turned on, so this is not abnormal.
Check again to see that all
Try operation again.
connectors are connected
Is operation normal?
securely.

Perform final check of operation.


PAM circuit
Phenomenon 1 (Rotation speed does not increase)

No
Is DC voltage 330V or more Check cords connected to
present across + , tab of system power module again. Check diode stack.
SPM2? If any cord is disconnected,
connect correctly.

Yes

Is OVL lamp lighting?


Where OVL lamp lights,
this indicates over-load If phenomenon persists,
and is not abnormal. replace system power module.

Over-voltage error (blinks 15 times): System power module (SPM2) is abnormal.

– 100 –
OPERATION USING SERVICE SWITCH OF OUTDOOR UNIT
RAM-50CNHZ2
1. Turn OFF power switch, then turn ON again.
2. Remove electrical parts box lid.
3. Press service switch for 1 second or more. (waiting at least 20 seconds after power switch is turned on.)
At this time, LD303 (red) lights and unit operates in forced cooling mode.

Never operate
continuously for 5
minutes or more
Service switch (Forced-cooling
operation starts by pressing for
Open upper lid. 1 second or more, and pressing
for 1 second or more again
stops operation.)

Electrical parts
box lid.

(Note)
(1) When checking is performed using service switch of outdoor unit, if both indoor units are not connected to interface signal
(DC35V) C.D terminals. LD304 (outdoor communication error indicator) will display communication error by blinking once.

(2) If operating is performed with compressor connector disconnected, LD301 will blink 4 times and operation will not start.

After operation using service switch is completed, turn the power switch OFF and then ON again.

HOW TO OPERATE OUTDOOR UNIT INDEPENDENTLY


1. Connect pipe to high pressure and low pressure side service valves.
Parts to be prepared
Outdoor unit Large diameter side
service valve
Connect large diameter and Universal un (1) Universal union
For outdoor
small diameter side service Compesser unit
(1/4 inch and 3/8 inch )
1/4 inch (6.35mm diameter)
values of outdoor unit using Reversing 3/8 inch (9.52mm diameter)
universal union and copper pipe valve
(2) Copper pipe (1/4 inch and 3/8 inch)
as shown on the right. (3) Lead wire for shorting
( Close)
Two wires of about 10 cm long with
For indoor unit
alligator clip or IC clip
Copper pipe
Apply vacuum and then (1/4 inch )
Small diameter side
charge refrigerant of 300g. service valve Never operate continuously for 5
( Close)
minutes or more.

Operation method is the same as that for operation using service switch of outdoor unit described above. However, interface
signal communication error (no input at C, D terminals) will be displayed when operation is complete.

– 101 –
TROUBLE SHOOTING
MODEL RAM-50CNHZ2

PRECAUTIONS FOR CHECKING

System power module


Power source
1ø220V-240V, 50Hz
a
N L
+

ACT-MODULE

Power module
– + + +
DANGER – M
– – –

1. Remenber that the
Compressor motor
0V line is biased to
155-170V in
b (0V)
reference to the
ground level.
Indoor unit
2. Also note that it takes electric parts
about 10 minutes C DC35V
until the voltage fall Control
D 0V MAIN P.W.B.
after the power switch P.W.B.
is turned off.

Across a – b (0V line).................... approx 360V


Across a – ground............................. approx 155-170V
Across b (0V line)– ground.............. approx 155-170V

Always keep your hands


and metallic things away
Outdoor unit P.W.B. from the enclosure of the DANGER!
oscilloscope. Don’t install
DANGER the ground
Oscilloscope line.
When using an
oscilloscope, never
ground it. Don't forget
that high voltages as
noted above may
apply to the
oscilloscope.

– 102 –
DISCHARGE PROCEDURE AND HOW TO CUT OFF POWER TO POWER CIRCUIT
RAM-50CNHZ2

Caution:
WARNING

● Voltage of about 360V is charged at both ends of smoothing capacitors 400 µF x 3.


● High voltage (DC 360V) is also charged at screw and terminal sactions of system power module.
● During continuity check for each circuit of electrical parts in outdoor unit is performed, to prevent
secondary trouble, disconnect red/gray wire connected to system power module (SPM2) from diode
stack. (Also be sure to perform discharging of smoothing capacitor.)

1. Turn off the power switch of indoor unit or disconnect power plug.
2. Wait for 10 minutes or more after power is turned off and then remove electrical parts box lid. As shown below,
Apply soldering iron of 30~75W for 15 seconds or more to P1 and N1 black/white lead receptacles on system
power module to discharge voltage from smoothing capacitor.
Do not loosen or remove screws of system power module: If screw is loose, voltage will not be discharged.
3. Before operation check of ech part of circuit, remove receptable of red/gray lead connected to system power
module from diode stack.

SMOOTHING CAPACITOR
Do not use soldering iron with
transformer: Doing so will blow
thermal fuse inside transformer.
N1 V
W

P1 L2
As shown left, apply soldering iron to metal
L1

parts (receptacles) in sleeve corresponding


to P1 and N1 terminals of system power
SPM (SYSTEM POWER MODULE) module (SPM2).

Soldering iron No. 2 No. 3 No. 4 No. 5

Screws of system power module (SPM2) are live parts: Do not


touch them. Screw tightening torque and method are strictly
specified.
When the screw is loosened or removed once, be sure to tighten
according to the procedure shown on the right, with tightening
torque of 0.8± 0.2 N · m.

Smoothing capacitor
(C501, C502, C503) No. 1 No. 7 No. 6
SPM2

GRN3

GRN1

Terminal
Power P.W.B Board (2p)
Control P.W.B
Reactor Diode Stack Switching Power P.W.B Service-switch
(D25 VB60) (For Indoor P.W.B.)

– 103 –
RAM-50CNHZ2
1. Outdoor unit does not operate (remote control signal can be received)

In hot weather, set operation mode to cooling,


room temperature to 16°C; in cold weather, set
to heating mode and 32°C, and then press
operation button.

Remove outdoor unit cover and


electrical parts box lid, and check
LD301 self-diagnosis lamp. Check room temperature thermistor.
If defective, replace it.
[Normal values]
10°C ➞ approx. 20kΩ
25°C ➞ approx. 10kΩ
Yes 30°C ➞ approx. 8kΩ

Check heat exchanger thermistor.


If defective,replace it.
[Normal values]
10°C ➞ approx. 20kΩ
Service Switch 25°C ➞ approx. 10kΩ
LD301 30°C ➞ approx. 8kΩ

Does LD301 blink once? Is indoor/outdoor communication


❈ Repeating to light for 0.25 sec. signal superimposed on DC35V?
and go off for 2 sec. Transmission waveform
38kHz of about 2Vp-p

No About
35V

Yes 0V No
Does LD304 in electric parts Check electrical parts of outdoor
box blink once when only one During check using tester: unit and repair defective parts.
indoor unit is connected? If superimposed, 35V rapidly (Around outdoor interface
changes. transmitting circuit).
Caution:
Digital tester only.

Yes

Is indoor transmission signal


generated at Q803 collector? No
38kHz Transmission waveform
Check indoor interface
of about 2Vp-p transmitting circuit.
About
No 4V
0V
During check using tester:
If generated, voltage rapidly
changes between 4V and 0V.
Check electrical parts of outdoor
unit and repair defective parts.
Yes (Around outdoor interface
transmitting circuit).

Does LD303 go off a few Check electrical parts of outdoor


seconds to ten and few seconds unit and repair defective parts.
after it is lit?

Perform final operation check.

– 104 –
Smoothing capacitor
(C501, C502, C503)
RAM-50CNHZ2

SPM2

GRN3

GRN1
1 Location of self-diagnosis lamp

– 105 –
Terminal
Power P.W.B
LIGHTING MODE SELF-DIAGNOSIS LAMP

Board (2p)
Control P.W.B
Reactor
Diode Stack Switching Power P.W.B Service-switch
(D25 VB60) (For Indoor P.W.B.)
2 Lighting mode self-diagnosis lamp
RAM-50CNHZ2

DANGER SELF-DIAGNOSIS LIGHTING MODE :LIT :BLINKING :OFF


L L

(DC360V) D
3
D
3 SELF-DIA-
WAIT FOR TEN-
0
1
0
2
RED RED
GNOSIS NAME DETAILS MAIN CHECK POINT
MINUTE(MIN) AFTER
TURNING OFF THE [1]DURING OPERATION LD303(RED)LIGHTS.
POWER SWITCH WHEN NORMAL COMPRESSOR
NOT MALFUNCTION
SERVICE WORK IS OPERATION OPERATION
BEING DONE. OVERLOAD
(1) (2) SET
VALUE

ROTATION
SHOULD BE CONFIRM (1)

SPEED
(3)
TO VOLTAGE LESS THIS SHOWS AN
OVERLOAD OVERLOAD,
THAN DC 10V (2)
TIME

THE ROTATION SPEED IS NOT MALFUNCTION.


AT MEASURING AUTOMATICALLY CONT-
POSITION. OVERLOAD ROLLED TO PROTECT THE
(3) COMPRESSOR IN THE
OVERLOAD CONDITION.
DO NOT TOUCH SCREW
OF SYSTEM POWER
[2]DURING STOP LD303(RED)GOES OFF.
MODULE DUE TO HIGH INDOOR THERMOSTAT OFF. NOT MALFUNCTION.
NORMAL MAIN OPERATION OFF.
VOLTAGE. STOP
DO NOT TOUCH OTHER RESET
WHEN STOPPED WITH
P.W.B.s (POWER CIRCUIT,
POWER RESET.
PARTS AT THE CASE 1TIMES STOP
(NORMAL WHEN POWER MICROCOMPUTER, ETC.)
HAS BEEN TURNED ON.)
OF PUSHING SERVICE
PEAK CURRENT OVERCURRENT SYSTEM POWER MODULE
1

SWTCH. IS DETECTED. 2 COMPRESSOR 3 P.W.B.s


2TIMES CUT
ABNORMAL POSITION DETECTION 1 SYSTEM POWER MODULE
LOW SPEED SIGNAL IS NOT INPUT 2 COMPRESSOR 3 P.W.B.s
SERVICE 3TIMES ROTATION DURING OPERATION.
OPERATION SWITCHING
SWITCHING FROM LOW 1 SYSTEM POWER MODULE
FREQUENCY SYNC START
TO POSITION DETECTION
2 COMPRESSOR 3 P.W.B.s
REFRIGERANT WITHDRAWAL OR SINGLE 4TIMES FAILURE OPERATION FAILURE.
UNDER THE LOWER LIMIT 1 OUTDOOR UNIT IS EXPOSED TO DIRECT
OPERATION OF THE OUTDOOR UNIT, OVERLOAD SUNLIGHT OR ITS AIRFLOW BLOCKED.
SHALL SWITCH OFF THE EXCLUSIVE OF ROTATION SPEED
WITH OVERLOAD CONTROL 2 FAN MOTOR 3 FAN MOTOR CIRCUIT
BREAKER FIRST. 5TIMES LOWER LIMIT CUT CIRCUIT OPERATED. 4
THE VOLTAGE IS EXTREMELY LOW.
PUT THE SWITCH TO ON POSITION LEAK OF REFRIGERANT 2 COMPRESSOR
OH THERMISTOR OH THERMISTOR
1
BACK AND WAIT AT LEAST 1 MINUTE.
OPERATED. 3 OH THERMISTOR CIRCUIT
THEN PUSH THE SERVICE SWITCH
WHICH IS ON THE CIRCUIT BOARD
6TIMES TEMP.RISE 4 FAN MOTOR 5 FAN MOTOR CIRCUIT
1 THERMISTOR 2 CONNECTION
FOR MORE THAN 1 SECOND. THERMISTOR THERMISTOR IS OPEN OR
(THERE WILL BE A COOLING CYCLE) SHORTED. OF THERMISTOR DEFECTIVE
TO PRESERVE PARTS FROM DAMAGE, 7TIMES ABNORMAL 3 THERMISTOR CIRCUIT

MUST NOT OPERATE IT FOR MORE


THAN 5 MINUTES. ACCELERATION NO ACCELERATION OVER 1 LEAK OF REFRIGERANT
THE LOWER LIMIT OF 2 COMPRESSOR
TO PAUSE, PUSH THE SERVICE SWITCH 8TIMES DEFECTIVE THE ROTATION SPEED.
AT LEAST 1 SECOND. IN CASE TO
START OPERATING ONCE AGAIN ABNORMAL POWER VOLTAGE 1 POWER VOLTAGE
PLEASE SWITCH OFF THE POWER BACK. IS ABNORMALLY LOW. 2 CONNECTION OF REACTOR
10TIMES POWER VOLTAGE
FAN LOCK OUTDOOR FAN RPM IS 1 FAN MOTOR
NOT ROTATE AS INTENDED 2
FAN MOTOR CIRCUIT
M A I N P.W.B .
12TIMES ERROR RPM
EEPROM MICROCOMPUTER CANNOT P.W.B.s (POWER CIRCUIT,
LD301 READ THE DATA IN EEPROM. EEPROM. ETC.)
LD302 13TIMES READ ERROR
LD303 ACTIVE CONVERTER OVERVOLTAGE IS SYSTEM POWER MODULE
LD304 DETECTED BY
14TIMES DEFECTIVE SYSTEM POWER MODULE
L NORMAL
SERVICE
D
SWITCH 3
0 COMMUNICATIONS BETWEEN 1 CABLE IS WRONG CONNECTED
4 COMMUNICA- INDOOR UNIT AND OUTDOOR 2 CABLE IS OPEN 3 INTERFACE
CIRCUIT BETWEEN INDOOR
GRN 1TIME TIONS ERROR UNIT ARE INTERRUPTED UNIT AND OUTDOOR UNIT

EXAMPLE OF
BLINKING (5 TIMES)
2SEC
( LIGHTS FOR 0.25
SEC AT INTERVAL
OF 0.25 SEC.
)

– 106 –
TROUBLESHOOTING OF THE SYSTEM POWER MODULE

Collector

BASE

Element circuit

Emitter

PGU PGV PGW

Circuit diagram
U V W
of the module

NGU NGV NGW

P1 N1 P2 U

Terminal symbol of
system module

See next page


for values
measured by
tester

L2L1 + —

Do not disassemble the system power module when troubleshooting is performed.

– 107 –
HOW TO CHECK POWER MODULE

Checking power module using tester


Set tester to resistance range (X 100)
If indicator does not swing in the following conductivity check, the power module is normal.
(In case of digital tester, since built-in battery is set in reverse direction, + and – terminals are reversed.)

CAUTION

If inner circuit of power module is disconnected (open), the indicator of tester will not swing and this may assumed as
normal. In this case, if indicator swings when + and – terminals are connected in reverse of diagram below Fig. 2, it
is normal. Furthermore, compare how indicator swings at U, V and W phases. If indicator swings the same way at each
point, it is normal.

– + – +

– + + –

P1 N1 P2 U P1 N1 P2 U

L2L1 + – + + L2L1 + – – –
W V W V

Fig. 1 Fig. 2

– 108 –
(JUDGING BETWEEN GAS LEAKAGE AND
CHECKING THE REFRIGERATING CYCLE COMPRESSOR DEFECTIVE)

1. Troubleshooting procedure (No operation, No heating, No cooling)


Lighting mode
Blinks Blinks Blinks Blinks Blinks Blinks
Connect U,V,W phase leads to the Self- 2 times 3 times 4 times 5 times 6 times 8times
diagnosis lamp
power module again and operate the
air conditioner. LD301

Time until the Approx. Within Approx.


Approx. 10 seconds 10 Approx. 10
lamp lights seconds 30 seconds
seconds

Possible
malfunctioning Compressor Gas Compressor
leakage
part

Is the self-diagnosis lamp mode as Blinking off


shown on the right?

YES

Normal
(0.39-0.98 MPaG)
(4-10 kg/cm2G)
Stop to operate and check the gas
pressure in balancing mode.

Gas leaking
(less than 4kg/cm2G)
When the
(less than 0.39 MPaG) self-diagnosis lamp
lights in the same
condition as above.

Gas leaks.
Repair and seal refrigerant. The compressor is defective. Replace it
and seal refrigerant.
If the compressor checker for an
(
inverter type air conditioner is
available, re-check using it. )

Perform a final check of operation.

– 109 –
PARTS LIST AND DIAGRAM
MODEL RAS-20CNHZ2

9
11

62
10
2

17

8
18
61

88
20

13 12
1

6
5
4
63
14 15
16

7
60

– 110 –
MODEL RAS-20CNHZ2

PART N0.
NO. Q’TY / UNIT PARTS NAME
RAS-20CNHZ2

1 PMRAS-20CNH2 004 1 CABINET

2 PMRAS-25CNH2 002 1 LOW-COVER

3 PMRAS-25CNH2 003 1 20W MOTOR


4 PMRAS-25CNH2 004 1 TANGENTIAL FLOW FAN

5 PMRAS-25CNH2 005 1 P-BEA ASSEMBLY

6 PMRAS-25CNH2 006 1 BEARING COVER


7 PMRAS-25CNH2 007 1 FAN MOTOR SUPPORT

8 PMRAS-25CNH2 008 1 ELECTRICAL COVER

9 PMRAS-20CNHZ2 002 1 DRAIN PAN ASSEMBLY


10 PMRAS-07C1 013 1 DRAIN HOSE

11 PMRAS-20CNHZ2 003 1 FRONT COVER ASS’Y

12 PMRAS-25CNH2 012 1 MOUNTING PLATE


13 PMRAS-40CNH2 021 1 REMOTE CONTROL

14 PMRAS-25CNH2 014 3 EVAPORATOR

15 PMRAS-10C6M 006 3 UNION (2)


16 PMRAS-09CHA1R 005 1 UNION (3)

17 PMRAS-10C6M 001 1 STEP MOTOR


60 PMRAS-10C3M 003 1 REMOTE CONTROL HOLDER

61 PMRAS-25CNH2 018 1 FILTER

62 PMRAS-25CNH2 019 2 CAP


63 PMRAS-25CNH2 020 1 PIPE SUPPORT

18 PMRAS-07C1 006 1 TERMINAL BOARD (2P)

20 PMRAS-20CNHZ2 001 1 P.W.B. (MAIN)


22 PMRAS-25CNH2 024 1 THERMISTOR

– 111 –
MODEL RAS-30CNHZ2

11

19

61

23 62
61 8 18

12

1
13

6 63
5

4
2

7 3

14
35
15
16 12
10

9
17 60

– 112 –
MODEL RAS-30CNHZ2

NO. PART N0.


Q’TY / UNIT PARTS NAME
RAS-30CNHZ2

1 PMRAS-30CNHZ2 006 1 CABINET

2 PMRAS-32CNH2 002 1 LOW-COVER

3 PMRAS-13C6M 001 1 20W MOTOR


4 PMRAS-09C1 003 1 TANGENTIAL FLOW FAN

5 PMRAS-05C 013 1 P-BEA ASSEMBLY

6 PMRAS-32CNH2 004 1 BEARING COVER


7 PMRAS-32CNH2 005 1 FAN MOTOR SUPPORT

8 PMRAS-30CNHZ2 002 1 ELECTRICAL COVER

9 PMRAS-30CNHZ2 003 1 DRAIN PAN ASSEMBLY


10 PMRAS-07C1 013 1 DRAIN HOSE

11 PMRAS-30CNHZ2 004 1 FRONT COVER ASS’Y

12 PMRAS-05C 009 1 MOUNTING PLATE


13 PMRAS-40CNH2 021 1 REMOTE CONTROL

14 PMRAS-30CNHZ2 005 1 EVAPORATOR

15 PMRAS-13C6K 003 1 UNION (2)


16 PMRAS-5142C 006 1 UNION (4)

17 PMRAS-05C 041 1 STEP MOTOR


18 PMRAS-07C1 006 1 TERMINAL (2P)

19 PMRAS-30CNHZ2 001 1 PWB (MAIN)

23 PMRAS-32CNH2 009 1 INDICATION BOARD


35 PMRAS-25CNH2 024 1 THERMISTOR

60 PMRAS-10C3M 003 1 REMOTE CONTROL HOLDER

61 PMRAS-32CNH2 015 2 FILTER


62 PMRAS-25CNH2 019 2 CAP

63 PMRAS-32CNH2 006 1 PIPE SUPPORT

– 113 –
MODEL RAM-50CNHZ2

30

23
29

36

20
16 19
18
21 17
37

38

40
34
41
28 31

22

35 26
13
27
24 11
12 7
10

15

14
2
3
32

4
1 33

8
9

– 114 –
MODEL RAM-50CNHZ2

PART N0.
NO. Q’TY / UNIT PARTS NAME
RAM-50CNHZ2

1 PMRAM-50CNHZ2 902 1 BASE


2 PMRAM-50CNHZ2 901 1 COMPRESSOR
3 KPNT1 001 4 PUSH NUT
4 RAC-2226HV 805 3 COMPRESSOR RUBBER
5 PMRAM-50CNHZ2 911 1 CONDENSER
6 PMRAC-128JHT 905 1 REVERSING VALVE
7 PMRAM-50CNHZ2 903 2 ELECTRICAL EXPANSION VALVE
8 PMRAM-50CNHZ2 913 2 VALVE (2S)
9 PMRAC-30CVP1 903 2 VALVE (3S)
10 PMRAC-40CNH2 914 1 THERMISTOR (OH)
11 PMRAC-25CNH2 909 1 THERMISTOR (OH) SUPPORT
12 RA-226 015 1 OVERLOAD RELAY COVER
13 RA-226 016 1 COVER SUPPORT
14 PMRAM-50CNHZ2 910 1 THERMISTOR (DEFROST)
15 PMRAC-32CNH2 905 1 MG-COIL
16 PMRAC-40CNH2 908 1 REACTOR
17 PMRAM-50CNHZ2 904 1 P.W.B (MAIN)
18 PMRAM-50CNHZ2 905 1 FUSE (3A)
19 PMRAC-40CNH2 906 1 FUSE (2A)
20 PMRAC-40CNH2 901 1 SYSTEM POWER MODULE
21 PMRAC-40CNH2 902 1 DIODE STACK (D25VB60)
22 PMRAS-07C1 006 2 TERMINAL BOARD (2P)
23 PMRAC-40CNH2 916 1 THERMISTOR (OUTSIDE TEMPERATURE)
24 PMRAC-40CNH2 917 1 PROPELLER FAN
26 PMRAC-40CNH2 918 1 SUPPORT (FAN MOTOR)
27 PMRAM-50CNHZ2 912 1 FAN MOTOR (40W)
28 PMRAC-40CNH2 904 1 CABINET
29 PMRAC-40CNH2 921 1 NET
30 PMRAC-40CNH2 922 1 TOP COVER
31 PMRAM-50CNHZ2 906 1 SIDE PLATE R
32 PMRAM-50CNHZ2 914 1 STRAINER
33 PMRAM-50CNHZ2 915 1 STRAINER
34 PMRAC-40CNH2 926 1 SIDE PLATE-L
35 PMRAC-40CNH2 928 1 GRILL
36 PMRAC-40CNH2 920 1 MOUTH RING
37 PMRAC-40CNH2 905 1 FUSE (25A)
38 PMRAM-50CNHZ2 907 1 PWB (POWER)
39 PMRAM-50CNHZ2 908 1 TERMINAL BOARD (2P)
40 PMRAM-50CNHZ2 909 1 P.W.B. (SW-POWER)
41 RA-108CHLXA 908 3 VARISTOR (450NR)