Interim Final
*9335427*
9335427
Disclaimer
This document has been reviewed in accordance with U.S. Environmental Protection .t"'\.~~vn~o:' policy and.
approved for publication. Mention of trade names or commercial products does not endorsement
or recommendation for use.
,,,'
ii
Preface
This document, Quality Assurance/Quality Control Guidance for Removal Activities, consists of two parts:
Part I- Sampling OA/OC Plan and Part II- Data Validation Procedures. The purpose of the Sampling
QA/OC Plan is to provide guidance in establishing, implementing, and using QAjQC protocols for data
collection activities performed under the Removal Program. The purpose of the Data Validation Procedures
is to provide guidance in reviewing laboratory data packages according to the guidance established by the
Sampling OA/OC Plan.
The policies and procedures established in this document are intended solely for the guidance of government
personnel. They are not intended, and cannot be relied upon, to create any rights, substantive or procedural,
enforceable by any party in litigation with the United States. The Agency reserves the right to act at variance
with these policies and procedures and to change them at any time without public notice.
Questions, comments, and recommendations are welcomed regarding the QAjQC Guidance for the Removal
Program. Send remarks to :
Ill
Quality Assurance/Quality Co.ntrol Guidance for
Removal Activities
EPA Work Group
EPA Headquarters
EPA Regional
Region 6:
Region 8:
Region 10:
Other Organizations
Roy F. Weston
In addition to the work group members, helpful suggestions and comments on the draft a~}curne11r
provided by the following as well as other EPA and contractor staff.
iv
TABLE OF CONTENTS
Section
1.0 Introduction
1
1.1 Purpose 1
1.2 Background
1
1.3 Analytical Methods and Data Quality 3
2.0 Elements of a Sampling QA/QC Plan 3
2.1 Title Page 4
2.2 Background •4
2.3 Data Use Objectives 4
2.4 Quality Assurance Objectives 4
2.4.1 Methods 7
2.5 Approach and Sampling Methodologies 7
2.6 Project Organization and Responsibilities
2.7 8
Quality Assurance Requirements 8
2.8 Error Determination (Analytical and Total Error) 9
2.8.1 Matrix Spike Sa~ples 9
2.8.2 Site Background Samples 9
2.8.3 Site Action Level Samples (Total Error) 10
2.9 Deliverables 10
2.10 Data Validation 10
LIST OF TABLES
v
TABLE OF CONTENTS
Page
Section
17
1.0 Introduction
17
2.0 Data Validation Qualifiers
18
3.0 Metallic Inorganic Parameters
18
3.1 Sample Holding Times 18
3.2 Initial and Continuing Calibration Verification 18
3.3 Blanks 19
3.4 ICP Interference Check Sample 19
3.5 Error Determination 19
3.5.1 Determination of Bias 19
3.5.1.1 Percent Recovery 19
3.5.1.2 Adjustment of Sample Value for Bias 19
3.5.2 Determination of Precision 19
3.5.2.1 Replicate Analysis 20
3.5.2.2 Coefficient of Variation 20
3.6 Performance Evaluation Samples 21
3.7 Optional Additional Instrument QC (for elevated concentrations) 21
3.7.1 ICP Serial Dilution 21
3.7.2 Atomic Absorption Analysis Specific QC 21
3.8 Overall Assessment of Data
21
4.0 BNAs by GC/MS Analysis ·.·•'"''
.. 21
4.1 Sample Holding Times ' 22
4.2 GC/MS Tuning Criteria '· 23
4.3 Initial and Continuing Calibration Verificatioi1 23
4.3.1 Internal Standards · 23
4.4 Error Determination 24
4.4.1 Determination of Bias 24
4.4.1.1 Percent Recovery 24
4.4.1.2 Adjustment of Sample Value for Bias 24
4.4.2 Determination of Precision 24
4.4.2.1 Replicate Analysis 24
4.4.2.2 Coefficient of Variation 25
4.5 Blanks 26
4.6 Compound Identification 26
4.6.1 Tentatively Identified Compounds '26
4.7 Compound Quantitation and Reported Detection Limits 21
4.8 Performance Evaluation Samples 27
4.9 Overall Assessment of Data 27
4.10 Optional QC Checks 27
4.10.1 Surrogate Recovery
vi
TABLE OF CONTENTS (continued)
Section
5.0 VOAs
27
5.1 Sample Holding Times
5.2 GC/MS Tuning Criteria 27
28
5.3 Initial and Continuing Calibration Verification
5.3.1 Internal Standards 28
5.4 Error Determination 29
5.4.1 Determination of Bias 29
5.4.1.1 Percent Recovery
29
29
5.4.1.2 Adjustment of Sample Value for Bias 29.
5.4.2 Determination of Precision
30
5.4.2.i Replicate Analysis
30
5.4.2.2 Coefficient of Variation 30-
5.5 Blanks
5.6 · Compound Identification ,
'3t"'
31
5.6.1 Tentatively Identified Compounds
32
5.7 Compound Quantitation and Reported Detection Limits 32
5.8 Performance Evaluation Samples ·
5.9 Overall Assessment of Data 32
5.10 Optional QC Checks 32
5.10.1 Surrogate Recovery 33
33
6.0 Pesticides/PCBs
33
6.1 Sample Holding Times
6.2 Instrument Performance 33
6.3 Initial and Continuing Calibration Verification
33
6.4 Error Determination 34
6.4.1 Determination of Bias 35
35
6.4.1.1 Percent Recovery . . 35
6.4.1.2 Adjustment of Sample Value for Bias. 35
6.4.2 Determination of Precision
35
6.4.2.1 Replicate Analysis 35
6.4.2.2 Coefficient of Variation 35
6.5 Blanks
6.6 Compound Identification 36
37
6.7 Compound Quantitation and Reported Detection Limits 37
6.8 Performance Evaluation Samples
6.9 Overall Assessment of Data 38
6.10 Optional QC Checks 38
6.10.1 Surrogate Recovery 38
38
7.0 PCBs
38
7.1 Sample Holding Times
7.2 Instrument Performance 38
38
7.3 Initial and Continuing Calibration Verification 39
vii
TABLE OF CONTENTS (continued)
Section
viii
TABLE OF CONTENTS (continued)
Section
ix
' l . '
> •
PART I
-
SAMPLING QA/QC PLAN
1.0 Introduction mandated or supported by EPA through regulations, grants,
contracts, or other formal means not currently covered by
Part I provides a detailed description of each section to be regulation. The responsibility for developing, coordinating,
contained in a "Sampling QA/QC Plan." The development and directing the implementation of this program has been
of the Sampling QA/QC Plan is the responsibility of the delegated to the Office of Research and Development
On-Scene Coordinator (OSC). The OSC reviews and (ORD), which has established the Quality Assurance
approves the site-specific plan and may obtain assistance Management Staff (QAMS) for this purpose. As stated in
from the Regional QA Officer. This guidance will help EPA Executive Order 5360.1, "Policy and Program
ensure that reliable, accurate, and quality data are Requirements to Implement the Mandatory Quality
obtained thrc,mgh field sampling efforts as well as field and Assurance Program," the primary goal of the QA program is
laboratory analytical services. The document to be to ensure that all environmentally related measurements
produced from this guidance is neither intended to performed or supported by EPA produce data of known
supersede nor replace the QA Project Plan; however, it is quality.The quality of· data is known when all
intended to augment the project plan by detailing site- components associated with its derivation are
specific information regarding sampling, analysis, and QA thoroughly documented, with.such documentation being
protocols. verifiable and defensible.
Note: QA/QC and QA are interchangeable terms used As part of their participation m the Agency-wide QA
throughout the guidance document. program, program offices are required to establish their own
. _"QA lrogram ~Pian.'' ; This. plan is to be prepared and
1.1 Purpose annually updated based on guidelines established by QAMS.
It specifies the quality of data required from environmentally
The purpose of this document is to provide guidance in related measurements and provides sufficient resources to
establishing, implementing, and using quality assure that an adequate level of QA is performed. The
assurance/quality control (QA/QC) protocols for data program plan is established at the Headquarters EPA level.
collection activities performed under the Removal For the Removal Program, the responsibility for the program
Program. plan lies with the Office of Emergency and Remedial
Response (OERR). In addition to program plans, plans
1.2 Background need to be developed for each regional office. These plans
are similar to the program plans, but are tailored to the
Agency policy requires that all EPA organizational units, specific operational needs of the regional office. The
including program offices, EPA regional offices, and EPA program and regional plans are both broad in scope and
laboratories, that perform environmentally related merely provide the objectives and resources for undertaking
measurements, participate in a centrally managed quality environmentally-related measurements.
assurance (QA) program, as stated in the Administrator's
Memorandum of May 30, 1979. This requirement applies The most specific element of QA documentation is the· QA
to all environmental monitoring and measurement efforts Project Plan (see Figure 1). A QA Project Plan specifics
1
II
the policies, organization (where applicable), objectives, The intent of this document is guidance on
functional activities, and specific QA and QC activities developing a site specific
designed to achieve the data quality goals of a specific assessing and substantiating data for ""'"U'\llC data users. The
project(s) or continuing operation(s). The QA Project guidance is not intended to
Plan is required for each specific project or continuing practices. It is assumed and ext>eclr~a
operation (or group of similar projects or continuing and analytical labs will follow
operation(s)). Guidance for preparing such plans is inherent QC checks) and adhere to accepted "good
contained in "Guidelines and Specifications for Preparing laboratory practices."
Quality Assurance Project Plans" (also known as QAMS-
005), which was developed by QAMS. This document
describes sixteen elements that must be considered for
inclusion in all QA Project Plans. QA Program Plan ( Level)
As per QAMS-004/80 idance
To meet the requirement for a QA Project Plan in the
removal program, the Emergency Response Division of
OERR established a QA Workgroup to provide guidance.
The workgroup decided that the QA Project Plan would
Regional QA Prn~~~m Plan
be divided into two functional documents: a generic (Regional 1) ·
"Branch QA Project Plan," and a site-specific "Sampling As per QAMS-004/80 idance
QA/QC Plan." When combined, both documents address
the sixteen elements described in QAMS-005. The Branch
QA Project Plan will be prepared by each regional
removal branch and will address only those elements
Generic QA Proj ,1 Plan
generic to all activities occurring within the Region; the.: (Branch Leve
Sampling QA/QC Plan will be prepared for each site As per QAMS..,.005/80.Guidance
where sampling will be performed and address those
clements specific to the site, such as sample collection and
analysis. The Branch Plan should be updated periodically
to reflect any operational changes in the Region. The Sampling QA/QC .Plan
Sampling QA/QC Plan should be prepared for each site (Site-Specif c)
As per OSWER Di . ive
and updated (amended) when the scope of work changes 9360.4-01 Gu
significantly from the scope of work described in any
previous plan. Elements that are not addressed in the
Sampling QA/QC Plan are included in the Branch Plan.
For emergency responses, a Sampling QA/QC Plan is
required to be submitted no later than 30 days after the This guidance has been designed
response date for documentation purposes. possible variation in monitoring str . However, it is
2
recognized that occasionally certain quality assurance
requirements cannot be met. In such cases, the reason for The guidance is structured around three quality assurance
the deviation should be stated in the Sampling QA/QC objectives. Each quality assurance objective is associated
Plan along with the expected or observed impact on the with a list of minimum requirements. Therefore, any
data. method or analytical instrument that can meet the quality
requirements can be used for any one of the objectives.
13 Analytical Methods and Data Quality
For example, if a spot test method was able to meet the
The quality of data is determined by its accuracy and requirements for QA3 (i.e., identify the specific analyte,
precision against prescribed requirements or specifications, determine the true concentration, and determine the error),
and by its us~fulness in assisting the user to make a then the spot test would not only be a valid method but it
decision or answer a question with confidence. The use of would give the same quality of data of a mass spectrometer
any one particular analytical method , or instrument, (assuming the mass spectrometer method met all the QA3
therefore, cannot determine the quality of data obtained requirements). It is anticipated that QAl and QA2 will
without an evaluation of the analytical accuracy (qualita- satisfy most data quality requirements for the Removal
tive and quantitative) of the data and of the relevance Program. QA3 is expected to be used only in those cases
(representativeness) of the data to user needs. Likewise, where an error determination is needed to identify false
certain analytical methods may provide more information negative or false positive values for critical decision level
than other. methods, but not necessarily better qu~ty data. concentrations.
information thaD:· a spectro~hotometer ~ethod: Ho.wever · The .Sampling QA/QC Plan:should contain the following
more information 'is not synonjnizous with accurate or ·sections:
useful data. Analytical quality is dependent o~ analytical
accuracy; that is to say that there is a degree of confidence Title page
associated with the data. The term accuracy refers to both • ·Background
the correctness of the concentration value and the Data Use Objectives
qualitative certainty that an analyte is present. Quality assurance objectives
Approach and sampling methodologies
This guidance is based on the idea that the use of any one Project organization and responsibilities
particular analytical method or instrument does not Quality assurance requirements
determine the quality of data obtained. This guidance • Deliverables
prompts the data collector to define the data quality within Data validation
a framework that also incorporates the intended use of the
data.
3
2.1 Title Page 2.4 Quality Assut,:ance Objectives
The title page should include the name of the site/project, For each data collection activity, the objective must
the contract and work order numbers (if the plan is being be specified to correspond to the data
prepared by contractors), the contractor name, the date, equally important QAjQC objectives
key project personnel, and the approval signatures of the assessing and substantiating the -.v........ ~-~·"'"
OSC and other appropriate. persons. (Although it is its intended use. The three
recommended that the QA Sampling Plan be reviewed by
Regional QA staff, it is not necessary that the plan ·be
approved by the Regional QA officer.) to determine which one or ...v •.uullJGlll'-~"
All three objectives provide and valid data for
2.2 Background enforcement purposes, disposal and/or treatment,
responsible party identification, and cleanup verification.
This section should provide a brief description of the The QA characteristics are based on thr Agency QA
events or occurrences that led to the iilltiation of the objectives for precision, accuracy (ooth quantitative and
sampling activity. This section may list chemicals which . . . ) ? representativeness,
qu alltahve . comp 11rteness, com parab"l"
1 lty,
agreements. Sources of such data include· inventories, objective for data quality is available for data
manifests, or other records; prior sampling data, such as coliection activid.es that involh r~pid, .non-rigorous
that generated by an RifFS; geological surveys; and methods of analysis and quality assurance. These
incidents of exposure. methods are used to ma~e quick, ·preliminary
assessments of types and of pollutants. The
primary reason for this is to allow for the
2.3 Data Use Objectives collection of the greatest a.u~,v...... of data with the
least expenditure of time money. The user
Before any sampling activity is conducted, the intended use should be aware that data for this objective
of the data must be determined. Careful consideration of have neither definitive · of pollutants nor
intended data use is critical because it will affect the QA definitive quantitation of
objective chosen and thereby maximize the probability of
making a correct decision based on the analytical results. data collected
The decisions to be made, questions to b~ addressed, or a calibration or
both, should be listed in this section. performance check of the u•v·,u•L•u is required along
4
with verification of the detection level. Methods will QA2: Rationale for QA2 objective:
be applied as per standard operating procedures and
;quipment manufacturer's specifications. QA2 .is a verification objective used· to verify analytical .
' ' ,,
(field or liib) results~ A minimum of 10% verification
The QA1 objective does not preclude the adherence . of results is required. This objective for data quality is
to prescribed quality control checks given in EPA available for data collection .activities that require
methods and SOPs or the manufacturer~s qualitative and/or qu~titative verification of a "select
recommendations. The QAl objective is generally portion of sample fm,dings". (10% or more) that were
' .- ' ·'
applied to but not limited to the following activities: acquired using non-rigorous methods of analysis and
' '' . ' . .' ' .
physical and/or chemical properties of samples; quality assurance. This quality objective is intended to
extent and d~gree of contamination relative to give the decision.;maker (OSC) a level of confidence for
concentration differences; delineation of pollutant a select portion of preliminazy data. T~is objective
plume in ground water (head space or soil gas allows the OSC to focus on specific pollutants and
analysis techniques); monitor well placement; waste specific Ieve~s of concentration quickly, by using field
compatibility;. preliminaty health and safety screening met~ods and verifYing at least 10% by more
asse,ssment; hazardous categorization; and preliminary . rigorous analytical methods and quality assurance, The
identification and quantitation of pollut~ts results of the 10% of substantiated data gives an
(determination of pH, flammability, chlorine associated sense of confidence for the remaining 90%.
presence, etc.). However, QA2 is not limited to only verifying screened
data. The QA2 objective is also applicaple to data that
QA1 Characteristics: are generated by any methodwhich.satisfies all the QA2
.. . '.:,
re~wirements and thereby. incorp~rates any. one or a
. ,- -
5
The QA2 objective is generally applied, but not
limited to the following activities: physical and/or
Note:
r
Error determination is advised if data are
being evaluated against critical action level.
chemical properties of samples; extent and degree a. Screened data- de~ermine the analytical
error by calcula,tmg the precision,
of contamination; verification of pollutant plume accuracy, and coefficient of variation for
definition in ground water; verification of health a subset (at least 110%) of the verified
data using an EP.tj\.-approved method.
and safety assessment; verification of pollutant b. Unscreened data - determine the
analytical error Iby calculating the
identification; and verification of cleanup. precision, accuracy, and coefficient of
variation for all!of the quantitative
OA2 Characteristics: results usinganElA-approved method.
• Analyte specific (i.e., benzene, cyanide, Note: If definitive quantitat~on is chosen along
2,3,7,8-TCDD, chromium). with definitive identifidation for all the data,
· then your data meet the QA3 objective.
• VERIFICATION of analyte identity
and/or concentration. Choose any one or Representative, comparabll, complete.
·requirem~nts
any combination of the following three:
QA for oljective "QA2" are
1. Definitive identification (choose one): specified in Section 2.7, "Quality Assurance
Requirements." ·
Note: Except for X-ray fluorescence
(XRF), confirmation of identity
applies to organic analytes only. QA3: Rationale for OA3 objective:
Confirm XRF determined analytes
by an EPA-approved method.
QA3 is a definitive objective! used to assess the
a. Screened data - confirm analyte accuracy of the concentration level. as well as the
identification by an EPA-approved
method, different from the screening identity of the analyte(s) of in~erest. This objective
method, on at least 10% of . for data quality is available[ for data collection
preliminary screened samples.
b. Unscreened data - confirm analyte activitie~ that require a high degree of qualitative and
identification by an EPA-approved quantitative accuracy ofall fi~dings using rigorous
method on all unscreened
environmental samples (field or lab). methods of analysis and qualityi.~ssu~ance for "critical
samples" (i.e., those samples fbr which the data are
2. Non-definitive quantitation (choose one):
considered essential ~ m~kiJg a decision). This
a. Screened data - verify arialyte quality objective is intended Ito give the decision
concentration on at least 10% of
preliminary screened samples (field maker (OSC) a level of confidence for a select gro\lp
or lab) using an EPA-approved of "critical samples" so he/shd can make a decision
method, different from the screening
method.
based on an action level with ~egard to:
I
treatment;
b. Unscreened data- determine analyte disposal; site remediation land/or removal of
concentration on all unscreened
environmental samples (field or lab) pollutants; health risk or e[vironmental impact;
using an EPA-approved method. cleanup verification; pollutant source identification;
6
for this quality objective. Error determinations provides. Quality is a matter of degree and can only be
are made for. all analytes that are of interest to assessed against specific criteria. Therefore, one can choose
the decision maker (OSC) for each critical any analytical method to use for any one of the three quality
sample that is of interest. assurance objectives in Section 2.4, provided all of the quality
assurance requirements are met for that objective as
OA3 Characteristics: specified in Section 2.7. The methods that can be used for
any of tjlese three objectives include, but are not limited to,
• Analyte specific.
spot tests; paper strip tests; indicator tubes; chemical
Definitive identification confirm reactions producing colors, gases, or precipitates; electronic
analyte identification by a second
method, such as mass spectroscopy, on meters such as Geiger counters, pH meters, conductivity
100% of the "critical samples" collected; meters; electronic detectors such as photoionization, electron
applies only to organic analytes.
capture, flame ionization, flame photometric, electrolytic, and
Note: Except for X-ray fluorescence infrared; gas chromatography; mass spectroscopy; atomic
(XRF), confirmation of identity
applies to organic analytes only. absorption; inductively coupled plasma (ICP), and X-ray
Confirm XRF determined analytes fluorescence. These methods may respond to either groups
by an EPA-approved method.
of analytes or specific analytes or both.
Non-definitive quantitation (choose one):
2:4.1 Methods
7
2.6 Project Organization and Responsibilities D. Initial and continuing .... ~......... o~• calibration data. ·
E. Method blank, rinsate trip blank data
(refer to Table 2, 2 and 3).
This section should list the managers, coordinators, and
F. Choose any one ·or of the
field sampling personnel, along with their project duties following three:
and responsibilities. The name and type of the laboratory
1. Definitive identification (
performing the analysis, if appropriate, should also be
included in this section. In addition, the parameters of a. Screened data - "uJ.u.u.,Jlll
of analytes via an bl'!A.-:aor,ro~<ect
interest (BNAs, VOAs, metals) should be detailed. different from the
or lab) on at least
screened samples
documentation such
2.7 Quality Assurance Requirements
b.
samples;
This section should describe the appropriate data quality
as gas
indicators and QA/QC protocols, based on the QAjQC etc.
objective determined in Section 3.0, which will be followed
2.
in the evaluation of lab data packages. A QAjQC
Analysis and Objectives Summary, including references to a. Screened data - --·'" ... ,•~
quantitative
analytical methods (see Table 3), should be completed. method and the
The data quality indicators of concern for each QA/QC method.
b. Unscreened data - ""'v'L'"'
objective are listed below. of quantitative 1c~.uu.::.:
(Documentation includes
on calculation procedures,
weight or volume, dilution
The following requirements apply: 3.
A. Sample documentation.
B. Instrument calibration data or a performance a. Screened data - rlot<-.-.~•.
check of a test method (i.e., Draeger tubes, error by calculating
test strips, spot tests). and coefficient of
C. Detection limit should be determined, unless and analyzing eight
inappropriate. the subset of
screening results
Note: QC procedures prescribed in SOPs and method. (See error
methods must be followed. 2.8.)
b. Unscreened data - rl..:ltPr·mi,,P the analytical
error by calculating precision, accuracy,
and coefficient of * by preparing
The following requirements apply: and analyzing eight QA replicates from
all of the samples using an EPA-
A. Sample documentation. approved method.
B. Chain of custody (optional for field screening G. Performance Evaluation ...,a,,uiJ'" (optional) and
locations). · where available. f
C. Sample holding times (document sample H. Detection limit should \:)e determined, unless
collection and analysis dates). inappropriate.
8
OA3: I. Performance Evaluation Samples, where
available.
The following requirements apply: J. Detection limit should be determined, unless
inappropriate.
A. Sample documentation.
B. Chain of custody.
C. Sample holding times (document sample Reference must be made to standard OA/OC protocols (i.e.,
collection and analysis dates). SOPs, EPA. reference procedures)
D. Initial and continuing instrument . for generating the above
calibration data. data quality indicator information.
E. Definitive identification:
Confirm the identification of analytes by 2.8 Error Determination (Analytical and Total Error)
an EPA-apprdved method on 100% of the
"critical" sam~les collected; and provide
documenta;tion such as gas Any one of the following options can be used when
chromatogram~, mass spectra, etc.
determing error for QA2 or QA3:
F. Non-definitive qtrantitation (choose one):
9
2.8.3 Site Action Level Samples (Total Error) Validation Procedures" in this guidanc~ document for the
appropriate evaluation criteria. These have been
Collect and analyze at least 8 replicate samples whose developed m~y from the Validation
analyte concentrations are equal to the level of interest. Functional Guidelines for Evaluation Organic, Inorganic;:,
(Do this by collecting one sample with sufficient material and Dioxin Analyses" ·used in the Agency's Contract
to divide into the required number of replicates. Except Laboratory Program.
for VOA samples, homogenize the sample thoroughly
before dividing into replicates.) These samples are from
the selected site and contain the target analyte at or near QA1 data need only be
detection limits criterion.
the level of interest. Determine bias (percent recovery)
and precision (coefficient of variation) according to
Section 35 of Part II- Data Validation Procedures. Bias The results of 10% of the samples the analytical data
can not be determined unless these samples are spiked packages should be evaluated all of the elements
listed in Section 2.7, "QA of the
ftrst and percent recovery is calculated. Sampling QA/QC Plan. The times, blank
contamination, and detection -..a.'a"' ..'" will be reviewed
for all remaining samples.
Note: This procedure (2.8.3) is useful in determining the
total (sampling and analytical) error as well as the
analytical error since it evaluates the sample collection, This objective, the most stringent all the objectives,
sample preparation, and the analysis. Sampling error requires that at least 10% of the in a lab data
package be evaluated for all of elements in
determination is being addressed in representative Section 2.7 "QA of the Sampling
sampling guidance documents for each media. These QAjQC Plan. Of the samples, holding
times, blank contamination, accuracy, error
documents are under development for removal activities. determination, detection and confirmed
identification data will be This objective also
requires review of all elements all samples in each
analyte category (i.e., VOAs and PCBs) in every lOth
2.9 Deliverables data package received from an · lab.
10
Table 1: Example Proposed Schedule of Work
(time period)
Item
1. Laboratory Procurement
5. Laboratory Analysis
6. Data Review
7. Draft Report
8. Final Report
11
Table 2: Field Sampling Summarv
QC Ext
Level
of Container Type Trip Total
Se~siti- * and Volume Preserv· Holding Subtotal Rinsat~ Blanks 3 QC Field
p., •• ..,.~t- .. r VI ty Matrix (# container rq'd) ative Times Samples Blanks (VOAs) Positi Samples
40ml vial
VOA s (1) 4•c 7 day
40ml vial
VOA w (3) 4•c** 7 day
8oz glass
BNA s ( 1) 4•c 7/40 d
8oz glass
PESTICIDE s ( 1) 4•c 7/40 d
8oz glass
PCB s (1) 4•c 7/40 d
8oz glass
CYANIDE s ( 1) 4•c 14 day
1 liter NaOH to
CYANIDE polyethylene pH > 12 14 day
( 1) 4•c
:..., Matrix: S·Soil, W·Water, o-oil, DS·Drum Solid, DL·DrlJ!l Liquid, TS-Tank Solid, TL-Tank Liqui
If residual chlorine is present, preserve with 0.008% Na 2s2 o2 .
I,
X-Other, A-Air
1. The concentration level, specific or generic, that is neectedlin order to make an evaluation. This level will
provide a basis for determining the analytical method to be used.
2. Only required if dedicated sampling tools are not used. For QA2 and QA3, one blank required per parameter per 20
samples. For QA1, enter "N/A 11 •
3. For QA2 and OA3, one trip blank required per cooler used to ship VOA samples. Each trip consists of two
40ml vials filled with distilled/deionized water. For OA1, enter "N/A".
4. Performance check samples; optional for QA2, mandatory for QA3 at one per parameter per matr x. For QA1, enter
11 N/A 11 •
5. For QA2 (optional) and for QA3 (mandatory): Determine bias (% recovery) using a minimum of matrix spikes.
Determine precision using a minimum of 8 matrix spikes. Ensure that sufficient environments sample is collected
for lab spiking. For QA1, enter "N/A".
12
Table 2: Field Sampling Summarv (continued)
QC Extras
Level
of Container Type Trip Total
lAna l yti cal Se':'Sifi· and Vollllle Preserv- Holding Subtotal Rinsat2 Blanks3 QC
4 Matrix5 Field
Parameter Vlty Matrix* (# container rq'd) ative ' Times Samples Blanks (VOAs) Positives Spikes Samples
PHENOLS s
8oz glass
(1) 4•c 28 day
••
•
liter amber
PHENOLS w
1
glass H~~o~ 2to 28 day
(1) 4•c
*** Matrix: S-Soil, W-Water, 0-0il, DS·Drum Solid, DL-Drum Liquid, TS-Tank Solid, TL-Tank Liquid, X-Other, A·Air
If residual chlorine is present, preserve with 0.008% Na s 0 • -
1. The concentration level, specific or generic, that is ne~in order to make an evaluation. This level will
provide a basis for determining the analytical method to be used.
2. Only required if dedicated sampling tools are not used. For QA2 and QA3, one blank required per parameter per 20
samples. For QA1, enter 11 N/A 11 •
3. For QA2 and QA3, one trip blank required per cooler used to ship VOA samples. Each trip blank consists' of two
40ml vials filled with distilled/deionized water. For QA1, enter "N/A".
4. Performance check samples; optional for QA2, mandatory for QA3 at one per' parameter per matrix. For QA-1, enter
11 N/A".
5. For QA2 (optional) and for QA3 (mandatory): Determine bias (%recovery) using a minimum of 2 matrix spikes.
Determine precision using a minimum of 8 matrix spikes. Ensure that sufficient environmental sample is collected
for lab spiking. For QA1, enter 11 N/A 11 •
13
Table 3: QNQC Analysis and Objectives Summary
OA/QC
Spikes
Analytical Analytical 1----..,.--.,-----......,.--i Detecti ~n
Parameter Matrix* Method Ref. Matrix Limits QA Objective4
VOA s 8240/SW-846
VOA 624/CLP
BHA 625/CLP
PESTICIDE s 8080/SW-846
PESTICIDE 608
PCB s 8080/S\l-846
PCB 608
P.P.
METALS s S\l-846
P.P.
METALS w EPA-600/CFR 40
CYANIDE s SW-846
CYANIDE S\l-846
* Hot~IX.
A·A1r
S·Soil, U·Uotec, O·Oil, Os-D'~ SaUd, DL·O'"' Uqoid, TS-Tonk Solid, TL-hnk Uqo~d,
..
X·Othec,
1. For OA2 (optional) and for QA3 (mandatory): Determine bias <%.recovery) using a minimllll of [2 matrix
spikes. Determine precision using a minimum of 8 matrix spikes. Ensure that sufficient enyironmental
sar.ple is collected for lab spiking. For OA1, enter 11 H/A 11 • 1
2. For OA2 and OA3, surrogate spike analysis is to be run for each sample; therefore, enter 11 yes 11 • For
OA-1, enter "H/A". I
3. To be determined by the person arranging the analysis. Should be equal to or less than the I level of
sensitivity. 1 ·
14
Table 3: ONOC Analysis and Objectives Summary (continued)
QAJQC
Spikes
Analytical Analytical Detecti~n
Parameter Matrix * Method Ref. Ma {1 su. v,., ...z Limits QA Objective4
PHENOLS s 8040/SIJ-846
.
1 .
PHENOLS IJ 604/CFR 40
.
1 .
* Matrix: S-Soil, IJ-IJater, 0-0il, DS-Drum Solid, DL-Drum Liquid, TS-Tank Solid, TL-Tank Liquid, X-Other,
A-Air
1. For cAa~ (optional) and for QA3 (mandatory): Determine bias (% recovery) using a minimum of 2 matrix
spikes. Determine precision using a minimum of 8 matrix spikes. Ensure that sufficient environmental
sample is collected for lab spiking. For CA1, enter "N/A".
2. For QA2 and QA3, surrogate spike analysis is to be run for each sample; therefore, enter "yes". For
QA-1: enter 11 N/A".
3. To be determined by the person arranging the analysis. Should be equal to or less than the level of
sensitivity.
4. Enter the QA Objective desired: QA1, CA2, or QA3.
15
PART IT
16
1.0 Introduction QAl - T~s objective requires review of only the
calibration and detection limits for all data.
17
3.0 Metallic Inorganic Parameters 2. Was a calibration ::.Li:lnu;a~ and blank analyzed at
the beginning of the au<nv"l" and after every 10
samples?
3.1 Sample Holding Times
1. Were any of the sample holding times ACTION: If no, flag as "''"l........"·•"'u (J) all values not
analyzed within 5 samples
exceeded?*
or blank.
Sample Holding Times:
Metals - 6 months 3. Were any sample results than 110% of the
Cyanide - 14 days highest calibration "<i:luuc:u
Mercury - 28 days
Chromium +6 - 24 hours
ACTION: reported as estimated
ACTION: If yes, flag as estimated (J) those values (J).
above the Instrument Detection Limit (IDL).
Values,that are less than the IDL can be flagged
as estimated (UJ) or rejected (R) based on .the 3.3
reviewers professionalj!Jdgement and the nature of
the sample and analyte. 1. Do the concentrations all blanks fall below the
IDL for all parameters?
*Because of their long shelf lives, performance
evaluation samples do not have any associated
holding times. positive data that has a cpncentration less than 5
times the blank value. I
I
Initial and Continuing Calibration Verification NOTE: In instances wher~ more than one blank is
3.2
associated with a given s~ple, qualification should
1. Are values outside the range of 90% to 110% of be based upon a comparison with the associated
the mean value, except for tin and mercury, for blank having the higheft concentration of a
which the range is 80% to 120%, and cyanide, contaminant. The results must not be corrected by
for which the range is 85% to 115%? subtracting any blank valu+
I
ACTION: If values are between 75-89% or 112- 2. Was one method blank analyzed for each 20
125% (65-79% and 121-135% for Hg and Sn, 70- samples?
84% and 116-130% for cyanide), flag as estimated
(J). ACTION: If no, flag as e~timated (J) all data for
which a method blank was rot analyzed. If only one
If values are outside of the above windows, reject blank was analyzed for mpre than 20 samples, the
(R) as unacceptable data between calibration first 20 samples analyzed do not have to be flagged
standard outside of above windows and nearest as estimated (J).
adjacent acceptable calibration standard(s).
18
3.4 ICP Interference Check Sample
% recovery for a single spiked sample =
1. If all ICP Interference Check Sample (ICS) Spiked sample cone. - Sample cone. x 100
results are not inside of control limits (.±. 20% Spike cone. added
. of mean value), are concentrations of Al, Ca,
Fe, or Mg lower in the sample than in the ICS? ACTION: If recoveries ani within applicable
control limits, no bias is considered. If %
ACTION: If no, flag as estimated (J) those sample Recovery is less than 80% or greater than
results for which ICS recovery is between.±. 50% 120%, the sample data should be flagged with
of mean value. For those sample results in which a (J) estimate and a corresponding (-) or ( +)
ICS recovery is above 150% or 50%, reject (R) all sign to show direction of the bias.
results. Adjustment of sample values should be
considered whenever there , is consistent
2. Was ICS analyzed at the beginning and end of evidence of bias.
each run or at least twice every 8 hours,
whichever is more frequent? 3.5.1.2 Adjustment of Sample Value for Bias
ACTION: If no, flag as estimated (J) all samples 1. Depending on bias direction, add or
for which AI, Ca, Fe, or Mg concentration is higher subtract the value (% Bias x spike
than in ICS. concentration) to or from the sample
values: % bias ,is the reciprocal value of
% recovery (i.e., for 70% recovery you
3.5 Error Determination have a negative 30% bias). Use the
See Part I - Section 2.8 for QA Samples to be used average % recovery from the total number
for error determination. of matrix spikes analyzed. This adjustment
approach assumes a spiking concentration
3.5.1 Determination of Bias (% Recovery - Optional for ,equal to the concentration found in the
QA-2; Mandatory for QA-3) sample.
19
I
I
Apply the CV to the decision level to determine
3.6 Performance Evaluation Salmples
the false negative or false positive value as I·
follows:
1. Were recovery limits ~ithin those set by the
20
ACTION: If outside the limits, review on a
2. When the method of standard addition was
compound by compound basis. If 50% of the
required, is the coefficient of correlation less than
compounds are outside of confidence limits or 0.995 for any sample?
were misidentified, all sample results should be
rejected (R).
ACTION: If yes, flag the associated data as
estimated (J).
ACTION: If yes, reject (R) affected data. Water I soil- analyze within 40 days after extraction
21
ACTION: If yes, flag as estimated (J) those values m/z Expanded ion abundance criteria
above the Instrument Detection Limit (IDL). 51 22-75% of mass 1~~
Values that are less than the IDL can be flagged 68 Less than 2% of xhass 69
as estimated (UJ) or rejected (R) based on the 69 (reference only) [·
70 Less than 2% of tpass 69
reviewers professional judgement and the nature of 30-75% of mass 198
127
the sample and analyte. 197 Less than 1% of fuass 198
198 Base peak, 100% !relative abundance
*Because of their long shelf lives, performance 199 5-9% of mass 19~ ·
275 7-37% of mass 198
evaluation samples do not have any associated 1
365 Greater than 0.75,% of mass 198
holding times. 441 Present, but less ~~an mass 443
442 Greater than 30% of mass 198
443 17-23% of mass 442
I
4.2 GC/MS Tuning Criteria I
ACTION: It is up to the re+~wer's discretion, based
1. Has decafluorotriphenylphosphine (DFTPP) on professional .judgemen~,~·to ~ag. data associat~d
been run for every 12 hours of sample analysis with tunes meetmg expanded cntena, but not bas1c
per instrument? criteria. If only one el~ment falls within the
expanded criteria, no qualihcation may be needed.
ACTION: If no, reject (R) all associated data for On the other hand, if sevefal data elements are in
that instrument which fall outside an acceptable the expanded windows, all aksociated data may merit
12-hour time interval. an estimated flag (J). NoteI that the data reViewer
.
may still choose to flag all data associated with a
2. Have the DFTPP ion abundance criteria been tune not meeting contract Jriteria as rejected (R) if
met for each instrument used? it is deemed appropriate. [
I
I
m/z Ion abundance criteria The most critical factors inl the DFfPP criteria are
the non-instrument specifih requirements that arc
51 30-60% of mass 198
68 Less than 2% of mass 69 also not unduly affected [by the location of the
69 (reference only) spectrum on the chromatographic profile. The m/z
70 Less than 2% of mass 69 198/199 and 442/443 ratios!are critical. These ratios
127 40-60% of mass 198 I
197 Less than 1% of mass 198 are based on the natural abundances of Carbon 12
198 Base peak, 100% relative abundance and C~bon 13 and should 1lways be met. Similarly,
199 5-9% of mass 198 the m/z 68, 70, 197 and ~1 relative abundances
275 10-30% of mass 198 indicate the condition of lthe instrument and the
365 Greater than 1% of mass 198
441 Less than mass 443 suitability of the resolution! adjustment and are very
442 Greater than 40% of mass 198 important. Note that all of the foregoing abundances
443 17-23% of mass 442 relate to adjacent ions; the* are relatively insensitive
to differences in instrumertt design and position of
ACTION: If no, evaluate against expanded ion
the spectrum on the chro~atographic profile. For
abundance criteria.
the ions. at m/z 51, 127, arid 275, the actual relative
abundance is n~t critical. !For in.sta~ce, if m/z 275
3. Have the appropriate expanded ion abundance
has a 40% relative abundan~e (cntena 10-30%) and
criteria been met for each instrument used?
other criteria are met, the !deficiency is minor. The
I
22
'} ,'
relative abundance of m/z 365 is an indicator of 4. Verify that the percent difference (%D) is .s_ 25%
suitable instrument zero adjustment. If m/z 365 for all BNA compounds in the continuing
relative abundance is zero, minimum detection calibration.
limits may be affected. On the other hand, if m/z
365 is present, but less than the 1% minimum ACTION: If any BNA compound has a %D between
abundance criteria, the deficiency is not as serious. the initial and continuing calibration of greater than
25%, flag all positive results for the compound as
estimated (J). Non-detects may be qualified (J) using
4.3 Initial and Continuing Calibration Verification the reviewer's professional judgement.
ACTION: If yes, reject (R) sample data for 1. Verify that all retention times and Internal
associated compounds. Standard (IS) areas are acceptable.
2. Verify that all BNA compounds have Relative ACTION: If an IS area is outside -50% or + 100%
Response Factors of at least 0.05. of the associated standard, flag the positive results as
estimated (J) for that sample fraction. Non-detects
ACTION: If any BNA compound has a Relative for compounds quantitated using that IS are flagged
Response Factor of less than 0.05, flag positive with the sample quantitation limit flagged as
results for that compound as estimated (J). Flag estimated (J) for that sample fraction. If extremely
non-detects for that compound as rejected (R). low area counts are reported, or if performance
exhibits a major abrupt drop-off, then a severe loss
3. Verify that all BNA compounds have a percent of sensitivity is indicated. Non-detects should then be
Relative Standard Deviation (%RSD) of .s_30% flagged as rejected (R).
for the initial calibration.
If an IS retention time vanes by more than 30
seconds, the chromatographic profile for that sample
%RSD = s X 100
X
must be examined to determine if any false positives
where: or negatives exist. For shifts of a large magnitude,
the reviewer may consider partial or total rejection
s. = standard deviation of 5 response factors (R) of the data for that sample fraction.
x = mean of 5 response factors
23
4.4.1 Determination of Bias (% Recovery- Optional for This adjustment annrt)ac:h assumes a spiking
the concentration
QA-2; Mandatory for QA-3)
where:
4.4.1.2 Adjustment of Sample Values for Bias
x0 L the decision ·level concentration
1. Depending on bias direction, add or I
subtract the value (% Bias x spike i
concentration) to or from the sample s = the sample sta~dard deviation given by
values. % bias is the reciprocal value the equation:
of % recovery (i.e., for 70% recovery
you have a negative 30% bias). Use
the average % recovery from the total s*
number of matrix spikes analyzed.
24
*Note: When using a programmable calculator suspect and should be reanalyzed. Values below 40
or computer statistics software, be sure the ppm are considered non-actionable. In most cases,
above equation with (n- 1) is used and not (n) the decision maker will be using the fq.lse negative
by itself. The equation using (n) is to determine value as his decision level and not be concerned
the population standard deviation ( o) rather about the false positive value. Whenever sample
than the sample standard deviation (s). values need to be corrected for both bias and
precision, first correct the value for bias, then correct
Apply the CV to the decision level to determine the biased value for precision.
the false negative or false positive value as
follows:
4.5 Blanks
False positive value Decision level value +
(CV x decision level) 1. Was a method blank extracted and analyzed for
each set of samples or every 20 samples of similar
False negative value = Decision level value - matrix and similar extraction technique?
(CV x decision level)
ACTION: If no, flag as estimated (J) all data for
Example: which a method blank was not analyzed. NOTE:
If only one blank was analyzed for more than 20
For an decision level = 50 ppm and CV = 20% samples, the first 20 samples analyzed do not have
to be flagged as estimated (J).
False positive value = 50 ppm + (20% x
50 ppm) 2. Has the method blank for BNAs been run on the
= 50 ppm + (10 ppm) same GC/MS or GC system as the sample?
= 60 ppm
25
contaminant. The results must not be corrected by -relative intensities soe:cu1ed above agree within
subtracting any blank value. 20% between and the reference
spectra.
4.6 Compound Identification
-molecular ions present the reference spectrum
1. Verify the following: are present in the
-the Relative Retention Time (RRT) of -all tentatively identified are reported
reported compounds is within 0.06 RRT units of with estimated quantitation and detection limits.
the standard RRT.
ACTION: Use professional judgement to determine
-all ions present in the standard mass spectrum acceptability of the data if the above criteria are not
at a relative intensity greater than 10% are also all met. If data are considdred to be unacceptable,
present in the sample mass spectrum. the tentative ID should be ~hanged to "unknown".
i
i
-all ions present in the sample, but not present
in the standard are accounted for. 4.7
I Reported Detection
Compound Quantitation and
Limits i
-relative intensities of the ions specified above
1. Verify that the reported +lues, both positives and
as present in the sample and at a relative
non-detects, have been coi,rectly adjusted to reflect
intensity greater than 10% in the standard,
all dilutions, concentrations, splits, cleanup
agree within 20% between the sample and the
procedures, dry weight i factors, an any other
standard spectra. adjustments that have nqt been accounted for by
I
'
The reviewer should contact the laboratory to
ACTION: If initial analysis and reanalysis both
verify any corrections made to the data.
have two or more surrogates outside of specifications
for samples or ~lanks, estimate (J) all quantitation
results, including detection limits.
, 4.8 . Performance Evaluation Samples
4.9 Overall Assessment of Data 1. Were any of the sample holding times exceeded?*
It is appropriate for the data reviewer to use Sample Holding Times from date of sample
professional judgment and express concerns and collection:
comments on the validity of the overall data
package for a case. This is particularly appropriate Aromatic (for water) - 7 days (unpreserved), 14
for cases in which there are several QC criteria out days (preserved)
of specification. The additive nature of QC factors
which are out of specification is difficult to assess All other compounds - 14 days
in an objective manner, but the reviewer has a
responsibility to inform the user about data quality Soil, sludge, sediments - 14 days
and data limitations. This helps the user to avoid
using data inappropriately, while not precluding ACTJrON: If yes, flag as estimated (J) those values
consideration of the data. The data reviewer above the Instrument Detection Limit (IDL). Values
would be greatly assisted in this endeavor if the that are less than the IDL can be flagged as
data quality objectives were provided. estimated (UJ) or rejected (R) based on the
reviewers professional judgement and the nature of
the sample and analyte.
4.10 Optional QC Checks
27
GC/MS Tuning Criteria but not basic criteria. one element falls
within the expanded qualification may be
1. Has bromofluorobenzene (BFB) been run for several data elements
every 12 hours of sample analysis per are in the expanded all associated data may
instrument? Note that the data
ACTION: If no, reject (R) all associated data for criteria as rejected
that instrument which fall outside an acceptable
12-hour time interval.
For BFB, the most ,.,.,,,..,.t.,n't factors to consider are
2. Have the BFB ion abundance criteria been met the empirical results that relatively insensitive to
for each instrument used? location on the profile and the type
of instrumentation. the critical ion
Ion abundance criteria abundance criteria for BFB the m/z 95/96 ratio,
the 174/175 ratio, the 176/ , and the 174/176 ratio.
50 15-40% of mass 95 The relative abundances m/z 50 and 75 are of
75 30-60% of mass 95
95 Base peak, 100% relative lower importance. I
abundance
96 5-9% of mass 95
173 Less than 2% of mass 174 I
Initial and Continuing Calibration Verification
174 Greater than 50% of mass 95 5.3
175 5-9'% of mass 174
176 95-101% of mass 174 1. Do any compounds hav~ an average response
177 5-9% of mass 176
factor equal to zero? I
I
ACTION: If no, evaluate against expanded ion i
28
where: 5.4 Error Determination
s = standard deviation of 5 response See Part I - Section 2.8 for QA samples to be used
factors for error determination.
29
values. % bias is the reciprocal value of % s = the sample sta.I?-dard deviation given by
recovery (i.e., for 70% recovery you have a the equation:
negative 30% bias). Use the average% recovery
from the total number of matrix spikes analyzed.
This adjustment approach assumes a spiking s* [ (X;- x)d/(n- 1)]Yz
1
i
1. The coefficient of variation (CV) is Example: !
used in determining the precision of I
standard deviation. The CV expresses For an decision level = 50 ppm and CV = 20%
the standard deviation as a percentage • •
I
I' •
of the mean (average) value of the False pos1t1Ve value = 50 ppm + (20% x
replicate values. The CV is used to 50 ppm) f
For the above false negative example, any values NOTE: In instances where more than one blank is
between 40 ppm and 50 ppm are considered associated with a given sample, quantification should
suspect and should be reanalyzed. Values below be based upon a comparison with the associated
40 ppm are considered non-actionable. In most blank having the highest concentration of a
cases, the decision maker will be using the false contaminant. The results must not be corrected by
negative value as his decision level and not be subtracting any blank value.
concerned about the false positive value.
Whenever sample values need to be corrected for
both bias and precision, first correct the value for 5.6 Compound Identification
. bias, then correct the biased value for precision.
1. Verify the following:
ACTION: If no, flag as estimated (J) all results ACTION: Use professional judgement to determine
that do not have an associated blank. acceptability of the data if the above criteria were
not all met. If it is · determined that incorrect
identifications were made, all such data should be
3. Are the concentrations of any blank reported as not detected with an estimated (J)
contaminants for VOAs greater than the RDL quantitation limit. Ions greater than 10% in the
of any VOA compound? sample spectrum but not present in the standard
spectrum must be considered and accounted for.
ACTION: For sample values reported at less than
10 times the blank contamination level for
methylene chloride, acetone, toluene and 2-
butanone and 5 times the blank contamination
31
I
I
5.6.1 Tentatively Identified Compounds Ax= area of characteristic i?n for compound being
tp.easured . . f· . .
-all ions presenting the reference mass spectrum Is = amount of internal stcrndard added (ng)
with a relative intensity greater than 10% are RF = daily response factor!. for compound being
present in the sample spectrum. measured I
v =
0
volume of water purged
I
( ml)
-relative intensities specified above agree within W= s weight of sample extracted (g)
20% between the sample and the reference D= (100 - % moisture) /~00 or. 1 on wet weight
spectra. basis i
32
and data limitations. This helps the user to avoid
using data inappropriately, while not precluding ACTION: If yes, flag as estimated (J) those values
consideration of the data. The data reviewer above the Instrument Detection Limit (IDL), based
would be greatly assisted in this endeavor if the on the reviewers professional judgement and the
data quality objectives were provided. nature of the sample and analyte. Values that are
less than the IDL can be flagged as estimated (UJ)
or rejected (R) based on the reviewers professional
5.10 Optional OC Checks
judgement and the nature of the sample and analyte.
6.1 Sample Holding Times 2. Check raw data to verify that retention time
windows are reported and that all pesticide
1. Were any of the sample holding times standards are within the established retention time
exceeded? windows.
Sample Holding Times from date of sample ACTION: If the standards do not fall within the
collection: retention time windows, professional judgement
should be used in the evaluation of associated sample
Water - 7 days to extraction results.
Soil, sludge, sediment - 14 days to extract
3. Check the raw data to verify that the percent
All - analyze within 40 days after extraction breakdown for endrin and 4,4'-DDT, or the
33
combined percent breakdown, does not exceed %RSD = s X 100
X
20% in all Evaluation Standard Mix B analysis.
where:
II
ACTION: If the DDT breakdown is greater than s = standard deviation of 5 resp~nse factors
20%, beginning with the last in-control standard x = mean of 5 response factors
'
flag all results for DDT as estimated (J). If DDT r·
was not detected,but DDD and DDE are positive, 2. If toxaphene or DDT seii~s was identified and
then flag the quantitation limit for DDT as rejected quantitated, verify that a tH~ee-point calibration
(R). Flag results for DDD and/or DDE as was established. I
presumptively present at an estimated quantity i
(NJ). ACTION: If no, flag as estimated (J) positive results
for toxaphene or DDT. II
If the endrin breakdown is greater than 20%, flag
I
all quantitative results for endrin as estim_ated{J}. 3. Verify the proper 72-hour ~nalytical sequence as
If endrin was not detected, but endrin aldehyde
follows: II
and endrin ketone are positive, then flag the
I
quantitation limit for endrin as rejected (R). Flag Standard Mix A, Standard Mix B, Standard Mix
results for endrin ketone as presumptively present
at an estimated quantity (NJ).
C _(individual standard mix +!
individual standard
miX B, may be one mix), rroxaphene, Aroclors
1016/1260, (Aroclor 1221, ~roclor 1232, once per
4. Check the raw data to verify that the percent month), Aroclor 1242, Aroclpr 1248, Aroclor 1254,
difference in retention time for the surrogate 5 samples, S.tandard Mix B,~ 5 samples, Individual
dibutylchlorendate (DBC) in all standards and Standard MIX A ?r B, 5 sa¢I>les, repeat starting
samples in .S. 2.0% for packed column analysis, from Standard Mix B, mu~t end with individual
.S. 0.3% for capillary column analysis, and .5. Standard Mix A and B. i·
1.5% for wide-bore capillary column analysis.
i
ACTION: If the proper staridards
!
have not been
ACTION: If any of the percentages are greater analyzed and the sequence foll~wed, use professional
than indicated, the analysis may be flagged as judgement to determine the seyerity of the effect and
rejected (R) for that sample. Qualification of the qualify the data accordingly. !
data is left up to the professional judgement of the - I
I
34
6.4 Error Determination values. % bias is the reciprocal value of
. % recovery (i.e., for 70% recovery you
See Part I - Section 2.8 for QA samples to be used have a negative 30% bias). Use the
for error determfuation.. average % recovery from the total number
of matrix spikes analyzed. This
6.4.1 Determination of Bias (% Recovery- Optional for adjustment approach assumes a spiking
QA-2; Mandatory for QA-3) concentration equal to the concentration
found in the sample.
6.4.1.1 Percent Recovery
1. Were at least eight spiked sample 6.4.2 Determination of Precision (Optional for QA-2;
replicates for the matrix of interest Mandatory for QA-3)
analyzed at the required frequency?
6.4.2.1 Replicate Analvsis
ACTION: If no, flag as recovery not
determined (RND) all data for which 1. Was a minimum of eight replicates
spiked samples were not analyzed. analyzed? If yes, determine coefficient of
variation. If no, flag data with precision
2. Determine the average recovery of the not determined (PND), for which replicate
eight spiked replicates. Is the average · samples were not analyzed.
recovery within the applicable control
limits (80% to 120%)? 6.4.2.2 Coefficient of Variation (Percent Relative Standard
Deviation)
% recovery for a single spiked sample =
Spiked sample cone. - Sample cone. x 100 1. The coefficient of variation ( CV) is used
Spike cone. added in determining the precision of standard
deviation. The CV expresses the standard
ACTION: If recoveries are within deviation as a percentage of the mean
applicable control limits, no bias is (average) value of the replicate values.
considered. If % Recovery is less than The CV is used to determine a false
80% or greater than 120%, the sample positive or false negative value for results
data should be flagged with a (J) estimate that are respectively greater than or less
and a corresponding (-) or ( +) sign to than a decision level concentration.
show direction of the bias. Adjustment of
sample values should be considered Determine the coefficient of variation
whenever there is consistent evidence of using the follo-wing equation:
bias.
CV = S X 100
6.4.1.2 Adjustment of Sample Values for Bias XDL
35
where: ppm are considered actionable.! In many cases, false
positives have been consider~d actionable by the
XoL = the decision level concentration Agency for safety reasons. H~wever, depending on
the action to be taken, this! · can be costly and
s = the sample standard deviation unjustifiable. Consult the QA lplan for intended use
I
(CV x decision level) 1. Verify that method blan~ analysis has been
reported per matrix, per ~oncentration level, at
False negative value = Decision level value - the proper frequency, for each GC system used
(CV x decision level) to analyze samples, for eacr extraction batch.
False negative value = 50 ppm - (20% x ACTION: Any pesticide dete~ted in the sample and
50 ppm) also detected in any assoc\ated blank, must be
= 50 ppm - (10 ppm) qualified as non-detect (U) when the sample
= 40 ppm concentration IS less thrn 5X the blank
concentration. 1
ACTION: If the qualitative criteria for dual Pesticide/PCBs for soils: ugjkg = .(A,.)(I.)(V,}
column or GC/MS confirmation were not met, all (A,.)(VV.)(D)(VJ
reported positive results should be flagged as
presumptively present at an estimated quantity
(NJ). A,. = area of quantitation peak(s)
I. = amount of standard injected (ng)
2. If multi peak pesticides (chlordane and
vi = volume of total extract (ul)
V; = volume injected (ul)
toxaphene)/PCBs were reported, were the
retention times and relative peak height ratios
v. = volume of sample (ml)
of major component peaks compared against
w. = weight of sample extracted (g)
the appropriate· standard chromatograms. D = (100 - % moisture) /100 or 1 for wet weight
basis
A. = Area of external standard
ACTION: If multipeak pesticides/PCBs exhibit
marginal pattern-matching quality professional
judgement should be used to establish whether the ACTION: If incorrect values have been reported, it
differences are attributable to environmental is essential that the correct values be determined.
"weathering". If the presence of a multipeak The reviewer should contact the laboratory to verify
any corrections made to the data.
pesticide/PCB is strongly suggested, results should
be reported as presumptively present (N).
37
i
I
I
i
2. If recoveries are out of control limits, use
6.8 Performance Evaluation Samples I
professional judgement II to determine the
1. Were recovery limits within those set by the apprepriate action. f
f
EMSL lab?
ACTION: If zero surrogat~, pesticide recovery is
ACTION: If outside the limits, review on a reported, determine whether ~he surrogate is outside
its retention time window. I~ yes, use professional
compound by compound basis. If 50% of the
judgement in the evaluation!. of this data. If the
compounds are outside of confidence limits or I
were misidentified, all sample results should be surrogate is not present, flag all negative results as
rejected (R). rejected (R). i'
I
6.9 Overall Assessment of Data 7.0 PCBs
It is appropriate for the data reviewer to use 7.1 Sample Holding Times
professional judgment and express concerns and
comments on the validity of the overall data 1. Were any of the sample h1lding times exceeded?
I
package for a case. This is particularly appropriate
for cases in which there are several QC criteria out Sample Holding Times [from date of sample
I
of specification. The additive nature of QC factors collection:
which are out of specification is difficult to assess I
in an objective manner, but the reviewer has a Water - 7 days to extract I·
responsibility to inform the user about data quality Soil, sediment, sludges - ~4 days to extract
I
and data limitations. This helps the user to avoid I
using data inappropriately, while not precluding All - analyze within 40 daiYs after extraction
consideration of the data. The data reviewer II
would be greatly assisted in this endeavor if the ACTION: If yes, flag as estimated (J) those values
data quality objectives were provided. above the Instrument Detechon Limit (IDL), based
on the reviewers professiottal
I
judgement and the
nature of the sample and arialyte. Values that are
6.10 Optional OA Checks less than the IDL can be ndgg;ed
I .
as estimated
.
(UJ)
or rejected (R) based on th~ reviewers professional
6.10.1 Surrogate Recovery judgement and the nature of: the sample and analyte.
i
1. Verify that the recoveries are within the control Because of their long slielf lives, performance
limits. evaluation samples do ndt have any associated
holding times.
ACTION: If not, check the raw data for possible I
interferences.
7.2 Instrument Performance
38
ACTION: If there is inadequate peak separation 4. Verify %D between calibration factors.
( <25% quantitation peak resolution), flag the data
as rejected (R). ACTION: If the %D for standard analysis is greater
than 15% on the quantitation column or greater than
2. Examine raw data and spot check the surrogate 20% on the confirmation column, flag all associated
compoUnd retention times. positive sample results as estimated (J).
J\CTION: If no, flag data as estimated (J). ACTION: If no, flag as recovery not determined
(RND) all data for which spiked samples were not
2. Verify that the %RSD of the calibration factor analyzed.
for all Aroclors is less than or equal to 10% for
the initial linearity check. 2. Determine the average recovery of the
eight spiked replicates. Is the average
%RSD = s X 100 recovery within the applicable control
X
limits (80% to 120%)?
where:
% recovery for a single spiked sample =
s = standard deviation of 5 response factors Spiked sample cone. - Sample cone. x 100
x = mean of 5 response factors Spike cone. added
39
7.4.1.2 Adjustment of Sample Values for Bias cv = s X 100
I .
XoLi.
1. Depending on bias direction, add or
subtract the value (% Bias x spike where: I
' f • '
concentration) to or from the sample . I •
x0 L the decisi~n level concentration
values. % bias is the reciprocal value
I
of % recovery (i.e., for 70% recovery I
you have a negative 30% bias). Use s = the sample ~tandard deviation given
the average % recovery for the total by the equation: :
I
number of matrix spikes analyzed. I Yz
This adjustment approach assumes a
. s* = [(Xj - x)f/(n - 1)]
d.
spiking concentration equal to the .I
concentration found in the sample. *Note:
. . When using I a programmable
calculator or computer statistics software, be
7.4.2 Determination of Precision (Optional for QA-2; sure the above equation with (n - 1) is used
Mandatory for QA-3) and not (n) by itself. t The equation using (n)
is to · determine rh~ population standard
I
7.4.2.1 Replicate Analysis deviation (u) rather than the sample standard
deviation (s)'. I:
I
1. Was a minimum of eight replicates
analyzed? If yes, determine coefficient !
Apply the CV to the decision level to
of variation. If no, flag data with determine the false *gative or false·positive
!
precision not determined (PND), for value as follows: !
. ~ ' ' i
which replicate samples were not I
40
and should be rean~yzed. Values above 60 ppm NOTE: In instances where more than one blank
are considered actionable. In many cases, false is associated with a given sample, quantification
positives have been considered actionable by the should . be based upon a comparison with the
Agency for safety reasons. However, depending on associated blank having the highest concentration of
the action to be .taken, .this can be costly and a contaminant. The results must not be corrected by
unjustifiable. Consult the QA plan for intended subtracting any blank value.
use of data and data quality objectives.
For the above false negative example, any values 7.6 Compound Identification
between 40 ppm and 50 ·ppm are considered
suspect and should be reanalyzed. Values below 1. Review the data to confirm that positive results
40 ppm are considered non-aCtionable. In most were identified using the correct retention time
cases,· the decision maker will be using the false window, peak height ratio, and "fingerprint"
negative value as his decision level and not be pattern. Determine which peak(s) were used to
concerned about the false pos1t1ve value. quantitate each Aroclor and verify that the fmger-
Whenever sample values need to be corrected for print pattern m:atches the standard chromatogram.
both bias and .precision, first correct the value for
bias, then correct the biased value for precision. ACTION: If the reported positive results were not
identified correctly, professional judgement should
be used to qualify the data.
41
7.7 Compound Ouantitation and Reported Detection 7.9 Overall Assessment of Data'
Limits
I
ACTION: If yes, flag as estimated (J) those values ACTION: If no, use professional judgement to flag
above the Instrument Detection Limit (IDL). all associated data.
Values that are less than the IDL can be flagged
as estimated (UJ) or rejected (R) based on the 3. Is the resolution of the valley between 2,3,7,8-
reviewers professional judgement and the nature of TCDD and the peak representing all other TCDD
the sample and analyte. isomers .s. 25%? (where, Valley(%) = X/Y x
100 and X is measured from the valley of the least
*Because of their long shelf lives, performance resolved adjacent isomer to the baseline, Y =
evaluation samples do not have any associated peak height of 2,3,7,8-TCDD).
holding times.
ACTION: If no, use professional judgement to
qualify all positive sample data associated with the
8.2 Instrument Performance standard... ·
2. Have the ion abundance criteria been met for -the ratios of ions 320 to 322 for 2,3,7,8-TCDD
each instrument used? and 332 to 334 for 13C 12-2,3,7,8-TCDD is .2:. 0.67
and .s. 0.87.
Ion abundance criteria -signal-to-noise ratios for ions 257, 320, 322 and
328 is .2:. 2.5 and the signal to noise ratios for ions
51 30-60% of mass 198 332 and 334 is .2:. 10.
68 Less than 2% of mass 69
69 (reference only) -the ions 257, 320, 322 for 2,3,7,8-TCDD reached
70 Less than 2% of mass 69 a maximum within three seconds of 13C12-TCDD
127 40-60% of mass 198 ions 332 and 334.
43
-during the unlabeled 2,3,7,8-TCDD calibration 8:5 Error Determination
the percent Relative Standard Deviation • I
(%RSD) of relative response factors for the five See Part I - Section 2.8 for bA samples to be used
I
calibration concentrations is less than or equal for error determination. I
to 15%.
8.5.1 Determination of Bias (% Recovery - Optional for
-during the 37Cl4-2,3,7,8-TCDD calibration the QA-2; Mandatory for QA-3)
%RSD of relative response factors for the three '
i
calibration concentrations is less than or equal 8.5.1.1 Percent Recovery i
I•
to 15%.
1. Were at least ;eight spiked sample
ACTION: If the calibration curve standards fail replicates for tlle matrix of interest
the acceptance criteria, use professional judgement analyzed at the re~uired frequency?
to qualify associated data.
'
ACTION: If no, I flag as recovery not
determined (RND) alldata for which spiked
8.4 Continuing Calibration samples were not an~lyzed.
t
-the ratios of ions are 320 to 322 for 2,3,7,8- %recovery for a single spiked sample =
' ' . ' i. ..
TCDD and 332 to 334 for 13C12-2,3,7,8-TCDD ~ Spiked sample cone. - Sample cone. x 100
0.67 and ..s. 0.87. · · Spike cone. a~ded
I
I
-the signal to noise ratios for ions are 257, 320, , ACTION: If recoveries are within applicable
I
322 and 328 ~ 25 and the noise ratios for ions control limits, no bias is considered. If %
!
332 and 334 ~ 10. Recovery is less thap. 80% or greater than
120%, the sample dat~ should be flagged with
-the ions are 257, 320, 322 for 2,3,7,8-TCDD a (J) estimate and a corresponding (-) or ( +)
reached a maximum within three seconds of sign to show dh:ectionI .
of the bias.
13
C12-TCDD ions 332 and 334. Adjustment of sample values should be
considered whenev6r there is consistent
-the percent difference of the relative response evidence of bias. I
factor is .±. 30% of the initial calibration. I
8.5.1.2 Adjustment of Samp~e Values for Bias
ACTION: If the calibration standard fails the r
44
I
I'
I
I
'
% recovery (i,e., for 70% recovery you where:
have a negative 30% bias). Use the
average % recovery from the total x0 L = · the decision level concentration
number 0f matrix spikes analyzed.
This adjustment approach assumes a s = the sample standard deviation given by
spiking concentration equal t.o the the equation:
conc.entration found in the sample.
45
have been considered actionable by the Agency for 8.7 Internal Standard Requirements
safety reasons. However, depending on the action !
to be taken, this can be costly and unjustifiable. 1. Did ion 332 or 334 fail the relative ion intensity
Consult the QA plan for intended use of data and criteria (~ 0.67 and ~ 9.87)? If yes, was the
data quality objectives. sample reanalyzed? :
•'
For the above false negative example, any values ACTION: If initial analysis ahd reanalysis both have
between 40 ppm and 50 ppm are considered ions 332 or 334 outside the relative ion intensity
I
suspect and should be reanalyzed. Values below criteria, reject all quantitaFon results, including
40 ppm are considered non-actionable. In most detection limits.
I
cases, the decision maker will be using the false I
I
negative value as his decision level and not be
I
concerned about the false positive value. 8.8 Identification of 2.3.7.8-TCDD
i
Whenever sample values need to be corrected for
both bias and precision, first correct the value for 1. Verify the following:
bias, then correct the biased value for precision. i'
-the retention time of th€1 sample component is
within three seconds of the retention time of the
13
8.6 C 12 - 2,3,7,8-TCDD.
I'
l
1. Has a method blank, spiked with the internal -the integrated ion current~ detected for m/z 257,
I
standards, been analyzed with each case? 320, and 322 maximize sin:tultaneously.
I
I
I
ACTION: If the method blank contains -the ion ratio of 320 to 322: and 332 to 334 is ~ .67
I
contaminants at the method detection limit of the and~ .87. !
I
matrix of interest, the blank must be reanalyzed. :;~'l
If the contaminated method blank was extracted -the integrated ion curre~t for each analyte and
along with a batch of samples the associated surrogate compound (m/'Z! 257, 320, 322 and 328)
positive samples must be reanalyzed. If the are at least 2.5 times backkround noise.
i
samples were not reanalyzed or if contamination is I
present in the second analysis, all positive sample -internal standard ions *re at least 10 times
results less than 5 times the concentration in the background noise. (The irltegrated ion current or
I
blank are flagged as non-detects (U). the internal standard ions· must not saturate the
I
detector.)
I
2. Has a reagent blank been analyzed along with
I
each case? -if the above requiremenFs were not met, then
reanalyze the samples. ·
I
ACTION: The reagent blank should be free of t·
contamination. If the level is > 0.10 ppb, use ACTION: If initial analysis abd reanalysis both have
professional judgement to qualify associated data. the sample outside the abov~ limits, 2,3,7,8-TCDD
was not qualitatively identifie~, reject (R) all positive
results.
46
ACTION: If no, reject all quantitation results, ACTION: For 37 Cl4-2,3,7,8-TCDD the ion 328
including detection limits. must have a signal to noise ratio of ~ 2.5. The
surrogate recovery must be ~ 60 and _::;_ 140 percent.
If the signal to noise ratio for ion 328 does not meet
8.9 Performance Evaluation Samples acceptance criteria, reject positive and ND data. If
surrogate recovery is outside acceptance limits, use
· 1. Were recovery limits within those set by the professional judgement to qualify associated data.
EMSLlab?
ACTION: If outside the. limits, review on a 9.0 Generic Data Validation Procedures
compound by compound basis. If 50% of the
compounds are outside of confidence limits or
were misidentified, all sample results should be 9.1 GC Analyses (i.e., Herbicides, Organophosphate,
rejected (R). Pesticides)
1. Was surrogate outside of specifications for any 1. Check the raw data to verify that there is adequate
samples? If yes, were the appropriate samples resolution ( > 25%) between peaks of the standard
reanalyzed? compounds.
47
i
I
ACTION: If adequate separation is not achieved, · all aSsociated positive sample results as estimated
I
flag all affected compound data as rejected (R). (J). i
!
3. Review the sample data to verify whether a applicable control limits, no bias is
standard was used as a quantitation standard or considered.: If % Recovery is less
. , than 80% or greater than 120%, the
as a confirmation standard. I
sample datl;l should be flagged with
ACTION: If the %D for standard analysis is
a (J) estimate and a corresponding
greater than 15% on the quantitation column or (-) or ( +) ~ign to show direction of
greater than 20% on the confirmation column, flag the bias. !Adjustment of sample
values sh;ould be considered
whenever there is consistent used to determine a false
evidence of bias. positive or false negative value
for results that are respectively
9.1.4.1.2 Adjustment of Sample Values greater than or less than a
for Bias decision level concentration.
49
I
I
False positive value = 50 ppm + (20% x 2. Verify that .all blank analy~es contain less than the
50 J?J?m) Required Detection L~its (RDL) of any
= 50 ppm + (10 ppm) compound or interfering peak.
= 60 ppm f
column analysis.
For the above false negative example, any values
between 40 ppm and 50 ppm are considered ACTION: If the qualitative ~riteria for dual column
suspect and should be reanalyzed. Yalues below were not Diet, all reported positive
I
results
, .
should be
40 ppm are considered non-actionable. In most flagged as presumptively p~esent at an estimated
cases, the decision maker will be using the false quantity (NJ).
negative value as hi~. _decision level. a!!d n.ot be
! . ' . - ....... . . } .....
concerned about the false positive value. 2. If· multipeak compounds were reported, were the
Whenever sample values need to be corrected for retention" tii:Ue's' and rdative '·pe~ height ratios of
both bias and precision, first correct the value for major component peaks compared 'against the
1
bias, then correct the biased value for precision. appropriate standard chromatograms.
method blank have not been analyzed, use 3. Verify that the sample chromatogram agree with
professional judgement to determine the effect on the correct daily standard dhromatogram, and that
I,
the data. the retention time windows match.
50
ACTION: If the chromatograms do not agree, and compounds are outside of confidence limits or
the retention time windows vary significantly, the were misidentified, all sample results should be
reviewer must use professional judgement to rejected (R).
determine the flags· that should be applied and the
usefulness of the data. 9.1.9 Overall Assessment of Data
9.1.7 Compound Quantitation and Reported Detection It is appropriate for the data reviewer to use
Limits professional. judgment and express concerns and
comments on the validity of the overall data package
1. Verify that the reported .values, both positives for a case. This is particularly appropriate for cases
··and non-detects, have been correctly adjusted to in which there are several QC criteria out of
reflect all dilutions, concentrations, splits, specification. The additive nature of QC factors
.cleanup procedures, dry weight factors, an any which are out of specification is difficult to assess in
other adjustments that have not been accounted an objective manner, but the reviewer has a
for by the method. responsibility to inform the user about data quality
and data limitations. This helps the user to avoid
For waters: ug/L = f&~l using data inappropriately, while not precluding
(A.)(V.)(V;)
consideration of the data. The data reviewer would
For soils: ug/L = .{t\,.)(I.)(V1} be greatly assisted in this endeavor if the data quality
(A.)(W.)(D)(V;) objectives were provided.
51
*Because of their long shelf lives, performance 2. Determin~ the average recovery
evaluation samples do not have any associated of the eight spiked replicates. Is
I
holding times. the·. average recovery within the
applicablri control limits (80% to
9.2.2 Initial and Continuin~ Calibration Verification 120%)? :
1. Verify that the %RSD of the calibration factor % recovery for a single spike~ sample =
for the calibration compounds are less than or Spiked sample cone, - Sample cone. x 100
equal to 10% for the initial calibration linearity Spike cone. added
check.
ACTION: If recoveries are within
ACTION: If criteria for linearity is not met, flag applicable control limits, no bias is
all associated quantitative results as estimated (J). i
considered. If % Recovery is less
than 80% or greater than 120%, the
2. Verify the proper analytical sequence was run sample data khould be flagged with
as required. a (J) estimate and a corresponding
(-) or ( +) sign to show direction of
ACTION: If the proper standards have not been the bias. .Adjustment of sample
analyzed and the sequence followed, use values should be considered
professional judgement to determine the severity whenever ~here is consistent
of the effect and qualify the data accordingly. evidence of bias.
52
9.2.3.2 ' Determination of Precision (Optional for s - the sample standard
QA~i; M~datory for QA~3) deviation given by the equation:
53
Consult the QA plan for intended use of data and 9.2.5 Compound Ouantitation ~d Reported Detection
data quality objectives. Limits
For the above false negative example, any values 1. Verify that the reported ':alues, both positives and
between 40 ppm and 50 ppm are considered non-detects, have been correctly adjusted to reflect
suspect and should be reanalyzed. Values below all dilutions, concentr~tions, splits, cleanup
40 ppm are considered non-actionable. In most procedures, dry weight •factors, and any other
cases, the decision maker will be using the false adjustments that have not been accounted for by
negative value as his decision level and not be the method.
concerned about the false positive value.
Whenever sample values need to be corrected for ACTION: If incorrect values have been reported, it
I
both bias and precision, first correct the value for is essential that the correct values be determined.
bias, then correct the biased value for·precision. The reviewer should contact the laboratory to verify
any corrections made to th~ data.
2. Verify that all blank analyses contain less than 9.2.7 Overall Assessment of Data
the Required Detection Limits (RDL) of any
compound or interfering peak. It is appropriate for the ·data reviewer to use
professional judgment and express concerns and
ACTION: Any compound detected in the sample comments on the validity ofthe overall data package
and also detected in any associated blank, must be for .a case. This is particularly appropriate for cases
qualified as non-detect (U) when the sample in which there are several QC criteria out of
'
concentration is less than 5X. the blank specification. The additive. nature of QC factors
concentration. which are out of specification is difficult to assess in
an objective manner, but the reviewer has a
NOTE: In instances where more than one blank responsibility to infbrm the user about data quality
is associated with a given sample, quantification and data limitations. This helps the user to avoid
should be based upon a comparison with the using data inappropriately, while not precluding
associated blank having the highest concentration consideration of the data. The data reviewer would
of a contaminant. The results must not be be greatly assisted in this enpeavor if the data quality
corrected by subtracting any blank value. objectives were provided.