Professional Documents
Culture Documents
COMPACTION MOLDS
Our molds are precision machined to standards and plated to resist corrosion. Our split molds are
split and held together with quick action clamps. Loosen these clamps and the mold opens slightly
for ease of specimen removal. All molds come complete with collar and detachable base.
Hydrometer(Set)
The Le Chatelier density flask isused to determine the densityof powdered materials. Thisflask has a capacity of
200ml,with the neck graduated from0 to 1ml below the bulb andfrom 18 to 24ml above the bulb.
Shipping Wt.: 3 lbs
10 ml 0.2 ml 1 lb.
25 ml 0.5 ml 1 lb.
50 ml 1.0 ml 1 lb.
100 ml 1.0 ml 1 lb.
250 ml 2.0 ml 1 lb.
500 ml 5.0 ml 1 lb.
1000 ml 10.0 ml 2 lbs.
2000 ml 20.0 ml 3 lbs.
The dimensions of the frame allow EN 12390-3, -4, -5, 12504-1, 1354,
the testing of concrete cylinders up
to 320 mm long x 160 mm 1521, 3161,1338, 772-6, 13286-41
diameter, 150and 100 mm square
cubes, and on EN/BS BS 3892-3, 187, 6717,
machines,200 mm square cubes.
c. All machines calibrated to BS EN ISO
Kerbs and flagstones may also be
tested on ADR machines as well as 7500-1;
150 mm and100 mm square section
beams to ASTM C78 using the ASTM E4;
optional 100 kN flexural frames
which are connected to the power i. ADR advanced digital readout
pack.
ii. High stability load frame
Load Indication
iii. Efficient hydraulic power pack
The ADR advanced digital readout
satisfies BS ENISO 7500-1, ASTM The ADR range of 2000 kN and 3000
E4, for calibrated accuracy and kNcapacity compression machines has
repeatability. been designed to meet the need for
reliable and consistent testing. The load
frame is a welded steel fabrication
carrying the ball-seated upper platen.
Positively located on the loading ram,
which is protected from debris by a
flexible cover, the lower platen is marked
for the centering of cube
This test is carried out by determining the percentage of the total mass of the aggregate that passes through slots
of a specified width in a metal plate.COLTO specifies that the test should be carried out on two fractions of the
aggregate, on the fraction passing 28 (25) mm and retained on 20 (19) mm, and the passing 20 (19) mm retained
on 14 (13.2) mm fraction.
14.Particle Density: Pycnometer Methods BS 1377, 812-2, EN 1097-7, EN 1997-2; ASTM D 854;
AASHTO T 100
These methods are generally suitable for fine-grainedsoils. The larger pycnometers are not usually suitable for
clay soils.
Ordering Information
EL24-2885 Pycnometer. Glass jar complete with noncorrodiblecone. Capacity 1 kg.EL24-2890 Density Bottle
25 ml (Nominal capacity).Supplied complete with capillary vent stopper. Conformsto BS 733 and ISO 3507.
Gay-Lussac type.EL24-2900 Density Bottle 50 ml (Nominal capacity).Supplied complete with capillary vent
stopper. Conforms
to BS 733, and ISO 3507. Gay-Lussac type.EL24-2950 Density Bottle 100 ml (Nominal capacity).Supplied
complete with capillary vent stopper. Gay-Lussac type.
Pycnometer Top
For determining specific gravity of fine aggregate. Top is spun brasswith 3/8" (10mm) hole in one end; threaded
end fits 1- or 2-qt.(1 or 2L) glass jar. Includes rubber gasket that fits on jar mouth toprevent fine particles from
becoming deposited in the threads. Orderjars separately.
Pycnometer top and 1qt. (.95L) glass jar set. Meets ASTM C128.
The analysis of soils by particle size provides auseful engineering classification system from whicha
considerable amount of empirical data can beobtained. Two separate and different procedures are used. Sieving
is used for gravel and sand size particles and sedimentation procedures are used for the finer soils. For soil
containing a range of coarse and fine particles it is usual to employ a composite test of sieving and
sedimentationprocedures. The Sand Equivalent Test serves as a rapid field test to show the relative proportions
of clay-like or plastic fine sand dusts in granular soils and fine aggregates.
16. Electrical Sieve Analysis/GRADATION-AGGREGATE TESTING
Sieve Analysis ByEndecottsSystem DescriptionThis sieve combines low cost withthe benefits of a well
designed andengineered shaker. The Minor Sieve Shaker shall be suitable for 200 mm, 8”, or 100
mmdiameter sleeves (sold separately). It isideal for either the laboratory or plantbecause it is
compact and genuinelyportable (weighing just 17 kg). Thereare no rotating parts, so it is quiet and
maintenance-free. The sieve stackis held firmly in position between thelocation and clamp plates by
straps thatallow the unit to fit in space less than200 mm high. For continuous timedsieving, set the 0
to 60 minute timer andselect “I”. The vibrating action impartsa precise movement to the sieve
stack,ensuring efficient sieving and excellentrepeatability. Anti-vibration feet ensuregood stability.
Weight: 17 kg
Specifications
The drum is rotated by a 1.0 hp Electric Motor. A heavy-duty speed reducer convertsthe motor speed to the
required drum speed of 30 to 33 revolutions per minute. Themachine is equipped with an adjustable
automatic counter that can be set to stop themachine at the required number of revolutions
CAUTION:On three phase models be sure that rotation of the drum is counterclockwise as seen from drive
end. More than momentary reverse rotation may damagecounter.The ratio-motor gear housing is shipped
with oil. Check the oil level and if necessary,be sure to lubricate in accordance with the instructions on the
motor plate and includedin this manual.
NOTE: The Operating Instructions forthe motor and for the right angle gear head are considered part of these
instructions.Pillow Blocks
The bearings in all Gear Pillow Blocks are pre-greased at the factory. When re lubricationis necessary use
recommended ball bearing grease of medium consistencyand apply by means of an ordinary grease gun and
the convenient grease fittingprovidedCounter
Wiring: Connect the blue and black wires to the motor on-off switch in the control box.Method of Operation:
Subtracting in one direction of rotation, adding when rotationis reversed. The counter subtracts from the
preset figure down to zero where a contactswitch is released. For knock-off at 9999, refer to particulars under
the heading “ControlContacts.”
Setting: Depress reset push button and hold it down. Preset the required figure bymeans of the individual
push buttons (sequence immaterial). Release reset push button.Repetition of count: By depressing the reset
push button once, the counter isautomatically set for a repetition of the preset cycle.
Control Contacts: Any of the following control contacts can be incorporated:
• Wiping contact at zero (duration of contact is for 1 count only and is, therefore,dependent on the counting
speed, e.g. 100 ms for gearing ratio of (50 revs = 1count at 10,000 rpm)
• Permanent contact at the changeover from 0000 to 9999, in which case onenumber less than required has
to be preset for correctness. This contact remains onuntil the counter is reset. Max presetting range is
8999.
• An additional fixed pre-contact (speed dependent wiping contact) can beincorporated at any given number
upon request.Safe load of contacts: Max. Switching output 30W 100 VAMax. Switching voltage 230VMax.
switching current 2AMaintenance: The counters do not require any particular attention. However, for
reliablefunctioning of these precision instruments careful handling is absolutely necessary.Operation
Machine
The Los Angeles Abrasion Testing Machine consists of a hollow steel cylinder, closedat both ends, having an
inside diameter of 28" and inside length of 20". The cylinderis mounted on stub shafts attached the ends of
the cylinder but not entering it andmounted in such a manner that it may be rotated about its axis in a
horizontal position.
An opening in the cylinder is provided for the introduction of the test sample. Theopening can be closed dust-
tight with the removable cover bolted in place.The cover is so designed as to maintain the cylindrical contour
of the interior surface.The shelf is so located that the charge will not fall in the cover or come in contact with
itduring the test.
A removable steel shelf projecting a radial 3- ½" into the cylinder and extending its fulllength is mounted along
one element of the interior surface of the cylinder. The shelfis of such thickness and so mounted by bolts or
other approved means to be firm &rigid. The position of the shelf is such that the distance from the shelf to
the openingmeasured along the circumference of the cylinder in the direction of rotation is not less
than 50".
If the cover stops at the bottom in a difficult to reach location, jog the barrel by pushingthe outer weight-plate
forward then reverse and pull to jog the barrel to the desiredposition.Abrasive chargesThe abrasive charges
consist of cast-iron spheres or steel spheres approximately1-7/8" in diameter and each weighing between
390g and 445g. The abrasive chargedepending upon the grading of the test sample as described on page 4
shall be asfollows:
Ordering Information
Los Angeles AbrasionTesting Machine with Abrasive Charge,220V 50 Hz
Optional Accessories
Abrasive Charge,consisting of 12 hardened steel balls of48 mm dia
18.BENCH OVENS
Our bench ovens are designed for generalpurpose laboratory drying of soils, aggregateand the heating of
asphaltic materials andcan be purchased with an optional exhaustadapter. These units have a large work area
and are stackable–making the most out ofyour work space.
STANDARD FEATURES:
OVENSS--HEATTIING EQUIIPMENTT
LAB OVENS
These gravity convection ovens are well-crafted,versatile and designed to meet your permanent
and field laboratory requirements. Temperature isthermostatically controlled with an incoloy shieldheating
element, enclosed in a heavy-duty doublewall cabinet and insulated with mineral wool forenergy efficiency.
Other models and sizes areavailable.
19. Aggregate Impact Value
Apparatus for the aggregate impact testThe apparatus consists of a steel test mould with a falling
hammer as shownin Figure 1. The hammer slides freely between vertical guides so arranged
that the lower part of the hammer is above and concentric with the mould.
Apparatus for the 10% fines test and aggregate crushing test
19.1. Aggregate Impact Tester with Blow Counter
System Description
This is used to determine the aggregate impact value and has been designedin accordance with
ASTM and BS ,ISOStandards. The sturdy constructionconsists of a base and support columns.
These form a rigid frame work aroundthe quick release trigger mechanismto ensure an effective free
fall of thehammer during test. The free fall canbe adjusted through 380 + 5 mm. The
hammer is provided with a lockingarrangement.Applicable StandardsBS 812-112
Ordering Information:
Aggregate Impact Tester withBlow Counter as per BS or ISO specifications
Optional Accessories:
Cylindrical Cup
Metal Measure,75mm ID x 50mm deep
Tamping Rod
Automatic Blow Count
20.Proctormoulds
20.Proctor rammers
Same as the 33-T0063/A EN version except for the complete set which also comprises the 0.1 cm. ft. mould
and the set of two pouring devices.s33-T0063/1
Vibrating table.230 V, 50 Hz, 1 ph.
Weight: 180 kg approx. ors33-T0063/1Z
Vibrating table. 110 V, 60 Hz, 1 ph.Weight: 180 kg approx. ors33-T0063/1Y
Vibrating table. 220 V, 60 Hz, 1 ph.Weight: 180 kg approx.
0.1 cu. ft. relative density mould set
Weight: 37 kg approx.
0.5 cu. ft. relative density mould set
Weight: 106 kg approx.
Relative density gauge set
Weight: 2 kg approx.
Set of two pouring devices,
12.5 and 25 mm dia.
Weight 1.5 kg approx.
This method is used for the laboratory evaluation of subgrade and subbase coarse materials in road
construction. The apparatus comprisesmoulds with accessories, compaction rammers (the automatic models
are the same used for the compaction of Proctor mouldsloading testing machines with accessories, etc.
conforming to the various specifications in useUnbound and hydraulically bound mixtures
Specifications
System Description
This equipment is used for measuringthe crushing resistance of an aggregate.
Applicable Standards
BS 812-110, 111
It shall be supplied as Standard With:
Cylindrical Cell
Plunger
Base Plate
Tamping Rod, 16mm dia,600mm lengthMetal Measure
Ordering Information:
Crushing Valve Apparatus,150mm as per ISO
Cylindrical Cell
Base Plate
Tamping Rod, 16mm dia,600mm length
Metal Measure
Crushing Valve Apparatus,75mm
.