1.

COMPACTION MOLDS

Our molds are precision machined to standards and plated to resist corrosion. Our split molds are

split and held together with quick action clamps. Loosen these clamps and the mold opens slightly
for ease of specimen removal. All molds come complete with collar and detachable base.

ITEM / SIZESHIPPING WT.

4” Compaction Mold: 1/30 cu.ft. 16 lbs. TL 1002

6” Compaction Mold: 1/13.33 cu.ft. 18 lbs. TL 1006

4” Split Compaction Mold: 1/30 cu.ft. 17 lbs. TL 1005

6” Split Compaction Mold: 1/13.33 cu.ft. 20 lbs. TL 1009

CBR Mold, Perforated Base: .1145 cu.ft. 22 lbs. TL 1011

Straight Edge: 12” x 1¼” x 1/8” 2 lbs. TL 1013

Hydrometer(Set)

ITEM / DESCRIPTIONSHIPPING WT.


Stirring Apparatus (115 Volt VAC) 15 lbs.
Dispersion Cup with Stationary Baffles 3 lbs.
Stirring Paddle (conforms to ASTM specifications) 1 lb.
Hydrometer (152 H) 2 lbs.
Hydrometer (151 H) 2 lbs.
Hydrometer Jar (1000 ml) 4 lbs.
ITEM/DESCRIPTION SIZE/CAPACITY SHIP. WT.
LIQUID LIMIT MACHINE10 lbs.
PLASTIC LIMIT PLATE12” x 12” x 3/8” 5 lbs.
Heavy duty plate glass, ground on one side.
(Our glass is ground, not sandblasted)
MOISTURE CANS3½” x 2” 4 lbs.
2½” x 1¾” 4 lbs.
2” x 7/8” 3 lbs.
MORTAR with rubber tipped pestle 5” dia. 5 lbs.
PESTLE
Rubber Tipped 8” x 1¼” 1 lb.
MIXING DISH250 ml 1 lb.
SPATULA
Stainless steel blade rounded 4” x ¾” 1 lb.
end with hardwood handle.
SQUEEZE BOTTLES250 ml 1 lb.
500 ml 1 lb. TL 1121
LIQUID LIMIT GROOVING TOOLS:
CURVED GROOVING TOOL 1 lb.
ASTM GROOVING TOOL METAL & GAUGE BLOCK        1 lb.
PLASTIC GROOVING TOOL 1 lb.

4.DENSITY SOIL SAMPLER


This type of tube sampler uses a thinwall tube driven into soil with a drophammer to obtain undisturbed soil
samples for perfoming tests. Comescomplete with 3 tubes
ITEM / SIZESHIPPING WT.
2” Density Soil Sampler 24 lbs. TL 1023
2” Density Tube 1 lb. TL 1024
3” Density Soil Sampler 26 lbs. TL 1025
3” Density Tube 2 lbs. TL 1026
4” Density Soil Sampler 28 lbs. TL 1027
4” Density Tube 2 lbs. TL 1028

ITEM / SIZESHIPPING WT.


Sand Cone Density Set 7 lbs.
Density Plate 6” 4 lbs.
Sand Cone Apparatus 6” 5 lbs.
Sand Cone Jar (Plastic) 2 lbs.
Density Sand 54 lbs.

5.SLUMP TEST SET


SLUMP SET ITEM/ DESCRIPTION The Slump Set is one of the most
SHIPPING WT. ORDER complete sets available, providing all
equipment needed to perform slump
Base Plate 12 lbs. tests. Also converts into a
transportable unit when slump cone
Slump Cone 5 lbs. and rod are properly attached .The
Best Set includes:
Tamping Rod 5/8” 3 lbs.
Base Plate, Slump Cone, Tamping
Tamping Rod w/ 8” Scale 3 lbs.
Rod, Scoop, Trowel and Pocket
Tamping Rod 3/8” 1 lb. Thermometer. The Standard Set
includes:
Concrete Scoops 2 lbs.
Base Plate, Slump Cone, Tamping
Slump Cone Funnel 4 lbs. Rod, and Scoop The Economy Set
includes:
Mixing Pan: 24”x 24”x 3” 20 lbs.
Base Plate, Slump Cone, and
Mixing Pan: 18”x 18”x 3” 12 lbs. Tamping Rod. Test is appropriate
ITEMS CAN BE PURCHASED SEPARATELY for concrete mixes of medium and
high workability. The test is
EN 12350-2; ASTM C143; AASHTO carried out by filling the slump
T119
cone with freshly mixed concrete,
which is tamped with a steel rod
Ordering Information in three layers. The concrete is
leveled off with the top of the
EL34-0110 Slump Cone complying with EN
12350-2, slump cone, the cone removed,
and the slump of the sample is
ASTM C143 and AASHTO T119 immediately measured

EL34-0130 Tamping Rod. Steel, 600 mm long


x 16 mm dia, hemispherical at both ends

EL34-0140 Steel Rule

EL34-0160 Base Plate

EL34-0180 Slump Cone Funnel

EL34-0192 Slump Test Set. BS and ASTM


comprising slump cone, base plate, steel
rule ,tamping rod and funnel
6.Moulding Equipment
Moulding Equipment4-Part Cube Test procedures require that
Moulds EN 12390-1, -2 specimens are cast in a number of
standard sizes convenient for
Ordering Information compressive and flexural strength
determination. The
EL34-4520 100 mm Cube Mould. 4-part
engineeringtolerances specified for
with clamp attached base plate. Weight 8.5
moulds are very stringent and the
kg.
internal finish of the surface must
EL34-4570 150 mm Cube Mould. 4-part be of a high order to comply with
with clamp attached base plate. Weight 18 the recommendations laid down in
kg. many International Standards.
Moulds must not deform during
EL34-4620 200 mm Cube Mould. 4-part manufacture of concrete specimens
with clamp attached base plate. Weight 35 if the specimen dimensions are to
kg. be maintained. Before the concrete
is scooped into the moulds the
Cube moulds are usually 150mm x 150mm moulds must be lightly coated in a
x 15 mm (or 100mm x100mm x100mm) mould release agent. This ensures
and can be made from steel or polyurethane. that the concrete does not stick to
The cube moulds must be manufactured to the mould and makes it easier to
the specifications / standards of the relevant remove the cube. When using a
body, in the UK it is the British Standards 150mm mould, the concrete
Institute to this specification BS EN 12390- sample is scooped into the mould
1:2000. in 3 equal layers (50mm) and
compacted between each layer.
There are various methods to
compact the concrete into the
moulds.
7.30 Kg Weighing Digital Concrete Field Scale
Digital concrete field scale. The Digital Concrete Field Scale
was developed to meet the
requirements of ASTM and
AASHTO specifications for unit
weight, yield and gravimetric air
content test applications. The
battery-powered scale has a 130
lb (60 kg) capacity with an
accuracy and readability of
0.02lb (10 g). The stainless steel
platformmeasures 17-3/4” by
13”. Theunit features a digital
indicator with 1” high, easy-to-
read digits,lb/kg selection
button, tarring up to full capacity
with indicator, low battery
indicator, adjustable leveling
feet, automatic zero and adurable
plastic covered wood carrying
case.

8. Digital Calipers/DIGITAL FRACTIONAL CALIPER

• Heavy Duty Stainless Steel


• Convenient Auto On/Off Feature
• 3 Mode Digital Display:
Decimal Inches, Fractions, Metric
SPECIFICATIONS:
• Range: 0-6 in. 0-153mm
• Accuracy: ±0.001 in. ±0.02mm
6” CALIPER:
Shipping Wt.: 2 lbs.
8” CALIPER:
Shipping Wt.: 3 lbs.
12” CALIPER:
Shipping Wt.: 4 lbs.

9.Specific Gravity Flask


The Chapman specific gravityflask is used to determineapproximate percent of voidsand surface moisture in
fineaggregate. This flask is graduatedto 200ml between bulbs andfrom 375ml to 450ml above thesecond bulb
Shipping Wt.: 3 lbs

Specific Gravity and Absorption of FineAggregate Kit


10.LE CHATELIERDensity Flask

The Le Chatelier density flask isused to determine the densityof powdered materials. Thisflask has a capacity of
200ml,with the neck graduated from0 to 1ml below the bulb andfrom 18 to 24ml above the bulb.
Shipping Wt.: 3 lbs

11. Graduated Cylinders

CAPACITYSUB DIVISIONSHIPPING WT.

10 ml 0.2 ml 1 lb.
25 ml 0.5 ml 1 lb.
50 ml 1.0 ml 1 lb.
100 ml 1.0 ml 1 lb.
250 ml 2.0 ml 1 lb.
500 ml 5.0 ml 1 lb.
1000 ml 10.0 ml 2 lbs.
2000 ml 20.0 ml 3 lbs.

12.ADR 2000 Compression Machines


ADR 2000 and 3000 2000 kN/450 000 lbf and 3000 kN/675 000
Compression lbfcapacity

Machines a. Three machine options

Specimen Capacity b. Machines to meet the requirements of

The dimensions of the frame allow EN 12390-3, -4, -5, 12504-1, 1354,
the testing of concrete cylinders up
to 320 mm long x 160 mm 1521, 3161,1338, 772-6, 13286-41
diameter, 150and 100 mm square
cubes, and on EN/BS BS 3892-3, 187, 6717,
machines,200 mm square cubes.
c. All machines calibrated to BS EN ISO
Kerbs and flagstones may also be
tested on ADR machines as well as 7500-1;
150 mm and100 mm square section
beams to ASTM C78 using the ASTM E4;
optional 100 kN flexural frames
which are connected to the power i. ADR advanced digital readout
pack.
ii. High stability load frame
Load Indication
iii. Efficient hydraulic power pack
The ADR advanced digital readout
satisfies BS ENISO 7500-1, ASTM The ADR range of 2000 kN and 3000
E4, for calibrated accuracy and kNcapacity compression machines has
repeatability. been designed to meet the need for
reliable and consistent testing. The load
frame is a welded steel fabrication
carrying the ball-seated upper platen.
Positively located on the loading ram,
which is protected from debris by a
flexible cover, the lower platen is marked
for the centering of cube

and cylinder specimens. Self-centering


lower platens for cube location are
supplied as standard on

EN machines andare available as an


optional extra on the standard machine.

The two machines for cube testing to EN


standards are assembled and aligned
using a special compression frame
stability tester.
13. Grading: Sieve Analysis Testing .Flakiness Index .Flakiness Index Apparatus

This test is carried out by determining the percentage of the total mass of the aggregate that passes through slots
of a specified width in a metal plate.COLTO specifies that the test should be carried out on two fractions of the
aggregate, on the fraction passing 28 (25) mm and retained on 20 (19) mm, and the passing 20 (19) mm retained
on 14 (13.2) mm fraction.

14.Particle Density: Pycnometer Methods BS 1377, 812-2, EN 1097-7, EN 1997-2; ASTM D 854;

AASHTO T 100

These methods are generally suitable for fine-grainedsoils. The larger pycnometers are not usually suitable for
clay soils.

Ordering Information
EL24-2885 Pycnometer. Glass jar complete with noncorrodiblecone. Capacity 1 kg.EL24-2890 Density Bottle
25 ml (Nominal capacity).Supplied complete with capillary vent stopper. Conformsto BS 733 and ISO 3507.
Gay-Lussac type.EL24-2900 Density Bottle 50 ml (Nominal capacity).Supplied complete with capillary vent
stopper. Conforms

to BS 733, and ISO 3507. Gay-Lussac type.EL24-2950 Density Bottle 100 ml (Nominal capacity).Supplied
complete with capillary vent stopper. Gay-Lussac type.
Pycnometer Top

For determining specific gravity of fine aggregate. Top is spun brasswith 3/8" (10mm) hole in one end; threaded
end fits 1- or 2-qt.(1 or 2L) glass jar. Includes rubber gasket that fits on jar mouth toprevent fine particles from
becoming deposited in the threads. Orderjars separately.

Pycnometer Top and Glass Jar

Pycnometer top and 1qt. (.95L) glass jar set. Meets ASTM C128.

15.Particle Size Distribution andSand Equivalent Value

The analysis of soils by particle size provides auseful engineering classification system from whicha
considerable amount of empirical data can beobtained. Two separate and different procedures are used. Sieving
is used for gravel and sand size particles and sedimentation procedures are used for the finer soils. For soil
containing a range of coarse and fine particles it is usual to employ a composite test of sieving and
sedimentationprocedures. The Sand Equivalent Test serves as a rapid field test to show the relative proportions
of clay-like or plastic fine sand dusts in granular soils and fine aggregates.
16. Electrical Sieve Analysis/GRADATION-AGGREGATE TESTING

Sieve Analysis ByEndecottsSystem DescriptionThis sieve combines low cost withthe benefits of a well
designed andengineered shaker. The Minor Sieve Shaker shall be suitable for 200 mm, 8”, or 100
mmdiameter sleeves (sold separately). It isideal for either the laboratory or plantbecause it is
compact and genuinelyportable (weighing just 17 kg). Thereare no rotating parts, so it is quiet and
maintenance-free. The sieve stackis held firmly in position between thelocation and clamp plates by
straps thatallow the unit to fit in space less than200 mm high. For continuous timedsieving, set the 0
to 60 minute timer andselect “I”. The vibrating action impartsa precise movement to the sieve
stack,ensuring efficient sieving and excellentrepeatability. Anti-vibration feet ensuregood stability.
Weight: 17 kg

Specifications

Height: 180 mm (excluding sievestack)


Timer: 0 to 60 min or continuous
Power: 230 V 50 Hz 80 VA
115 V 60 Hz 60 VAother voltages on request
Capacity: up to 8 full height 200 mm (8")sieves
Ordering Information) :automatic sieve shaker
17.Los Angeles Abrasion Machine with 12 Balls/AGGREGATE TESTING MACHINE:

The drum is rotated by a 1.0 hp Electric Motor. A heavy-duty speed reducer convertsthe motor speed to the
required drum speed of 30 to 33 revolutions per minute. Themachine is equipped with an adjustable
automatic counter that can be set to stop themachine at the required number of revolutions

Packing & Assembly


Each unit is shipped complete with a set of 12 charges and a collector pan. Generally thecollector pan and the
carton containing the charges is wire strapped to the lower crossmembers of this machine.

Electrical Motor and Speed Reducer


It shall be examined that the motor carefully to make sure that it has not been damaged duringshipment. Be
sure that the line voltage and frequency correspond to those stamped onthe nameplate. For connections, see
diagram attached to the machine.

CAUTION:On three phase models be sure that rotation of the drum is counterclockwise as seen from drive
end. More than momentary reverse rotation may damagecounter.The ratio-motor gear housing is shipped
with oil. Check the oil level and if necessary,be sure to lubricate in accordance with the instructions on the
motor plate and includedin this manual.

NOTE: The Operating Instructions forthe motor and for the right angle gear head are considered part of these
instructions.Pillow Blocks

The bearings in all Gear Pillow Blocks are pre-greased at the factory. When re lubricationis necessary use
recommended ball bearing grease of medium consistencyand apply by means of an ordinary grease gun and
the convenient grease fittingprovidedCounter

Wiring: Connect the blue and black wires to the motor on-off switch in the control box.Method of Operation:
Subtracting in one direction of rotation, adding when rotationis reversed. The counter subtracts from the
preset figure down to zero where a contactswitch is released. For knock-off at 9999, refer to particulars under
the heading “ControlContacts.”

Setting: Depress reset push button and hold it down. Preset the required figure bymeans of the individual
push buttons (sequence immaterial). Release reset push button.Repetition of count: By depressing the reset
push button once, the counter isautomatically set for a repetition of the preset cycle.
Control Contacts: Any of the following control contacts can be incorporated:
• Wiping contact at zero (duration of contact is for 1 count only and is, therefore,dependent on the counting
speed, e.g. 100 ms for gearing ratio of (50 revs = 1count at 10,000 rpm)
• Permanent contact at the changeover from 0000 to 9999, in which case onenumber less than required has
to be preset for correctness. This contact remains onuntil the counter is reset. Max presetting range is
8999.
• An additional fixed pre-contact (speed dependent wiping contact) can beincorporated at any given number
upon request.Safe load of contacts: Max. Switching output 30W 100 VAMax. Switching voltage 230VMax.
switching current 2AMaintenance: The counters do not require any particular attention. However, for
reliablefunctioning of these precision instruments careful handling is absolutely necessary.Operation
Machine

The Los Angeles Abrasion Testing Machine consists of a hollow steel cylinder, closedat both ends, having an
inside diameter of 28" and inside length of 20". The cylinderis mounted on stub shafts attached the ends of
the cylinder but not entering it andmounted in such a manner that it may be rotated about its axis in a
horizontal position.

An opening in the cylinder is provided for the introduction of the test sample. Theopening can be closed dust-
tight with the removable cover bolted in place.The cover is so designed as to maintain the cylindrical contour
of the interior surface.The shelf is so located that the charge will not fall in the cover or come in contact with
itduring the test.

A removable steel shelf projecting a radial 3- ½" into the cylinder and extending its fulllength is mounted along
one element of the interior surface of the cylinder. The shelfis of such thickness and so mounted by bolts or
other approved means to be firm &rigid. The position of the shelf is such that the distance from the shelf to
the openingmeasured along the circumference of the cylinder in the direction of rotation is not less
than 50".

If the cover stops at the bottom in a difficult to reach location, jog the barrel by pushingthe outer weight-plate
forward then reverse and pull to jog the barrel to the desiredposition.Abrasive chargesThe abrasive charges
consist of cast-iron spheres or steel spheres approximately1-7/8" in diameter and each weighing between
390g and 445g. The abrasive chargedepending upon the grading of the test sample as described on page 4
shall be asfollows:

Grading Number of Spheres Weight of Charges, g.


A 12 5000 ± 25
B 11 4584 ± 25
C 8 3330 ± 20
D 6 2500 ± 15
1. Thickness Gauge.
2. Length Gauge.
3. Cylindrical Measures.
4. Aggregate Impact Testing Machine.
5. Metal Measures.
6. Specific Gravity & Water Absorption of Aggregates.
7. Riffle Sample Divider for sampling Aggregates, Testing.
8. Dorry Abrasion Testing Machine.
9. Los Angeles Abrasion Testing Machine.
10. Air Entrainment Meter.
11. Aggregate Impact Value Test Apparatus.
12. Aggregate Crushing Value Apparatus.
13. Sand Absorption Cone and Tamper.
14. Pycnometer.
15. Sieve Shaker Hand Operated.
16. Sieve Shaker- Gyratory.
17. Sieve Shaker Rotap
18. Density Basket.
19. Deval Attrition Test.
20. Jaw Crusher.
21. Pulveriser.
22. Tile Abbrasion Testing Machine.
23. Pug Mill for grinding Lime Mortar.

Los Angeles Abrasion Testing Machine


This machine is for determining the resistance to wear of small size
coarse aggregates and crushed rock. The machine consists of a hollow
cylinder, mounted on a sturdy frame on ball bearings. A detachable
shelf which extends throughout the inside length of the drum catches
the abrasive charge and does not allow it to fall on the cover. The drum
is rotated at a speed of 30-33 rpm by an electric motor through a heavyduty
reduction gear. Motor is suitable for operation on 220 V, 1 phase,
50 Hz, AC Supply. Supplied complete, with a tray for collection of the
material, and abrasive charge
Meets :- IS: 2386 (Part 4), BS: 812, ASTM C- 131, AASHO T96
MI.SA-1005D
Los Angeles Abrasion Testing Machine with Digital Indicator
Optional
MI.SA-1005001
Abrasive charge,
A set of 12 hardened steel balls of 48 mm diameter

For ASTM Standards:

TO-45801-ASTM Abrasive Charge,consisting of a set of 12 hardened steelballs of 48 mm diaFor AUS Standards:

TO-45801-AS Abrasive Charge,consisting of 12 hardened steel balls of48 mm dia

Ordering Information
Los Angeles AbrasionTesting Machine with Abrasive Charge,220V 50 Hz
Optional Accessories
Abrasive Charge,consisting of 12 hardened steel balls of48 mm dia

18.BENCH OVENS
Our bench ovens are designed for generalpurpose laboratory drying of soils, aggregateand the heating of
asphaltic materials andcan be purchased with an optional exhaustadapter. These units have a large work area
and are stackable–making the most out ofyour work space.
STANDARD FEATURES:

• Fan Forced Air Circulation


• Incoloy Sheathed Elements
• Automatic Thermo Control
• Pilot Light Heat Indicator
• Mineral Wool Insulation
• All Steel Aluminized Interior
• Fully Gasketed Doors
• Adjustable Damper Control
• Piano-Type Door Hinges
• High Heat Switch
• Adjustable Shelves 3” Centers
• Silicone Baked Enamel Finish
• 18 Month Warranty

OVENSS--HEATTIING EQUIIPMENTT

LAB OVENS

These gravity convection ovens are well-crafted,versatile and designed to meet your permanent
and field laboratory requirements. Temperature isthermostatically controlled with an incoloy shieldheating
element, enclosed in a heavy-duty doublewall cabinet and insulated with mineral wool forenergy efficiency.
Other models and sizes areavailable.
19. Aggregate Impact Value
Apparatus for the aggregate impact testThe apparatus consists of a steel test mould with a falling
hammer as shownin Figure 1. The hammer slides freely between vertical guides so arranged
that the lower part of the hammer is above and concentric with the mould.

Apparatus for the 10% fines test and aggregate crushing test
19.1. Aggregate Impact Tester with Blow Counter

System Description

This is used to determine the aggregate impact value and has been designedin accordance with
ASTM and BS ,ISOStandards. The sturdy constructionconsists of a base and support columns.
These form a rigid frame work aroundthe quick release trigger mechanismto ensure an effective free
fall of thehammer during test. The free fall canbe adjusted through 380 + 5 mm. The
hammer is provided with a lockingarrangement.Applicable StandardsBS 812-112

It shall be Supplied As Standard With:


Cylindrical Cup
Metal Measure, 75mm ID x50mm deep
Tamping Rod
Automatic Blow Counter

Ordering Information:
Aggregate Impact Tester withBlow Counter as per BS or ISO specifications

Optional Accessories:
Cylindrical Cup
Metal Measure,75mm ID x 50mm deep
Tamping Rod
Automatic Blow Count

20.Proctormoulds

20.Proctor rammers

Proctor steel plates

Testing equipment for the construction industry


Compaction equipment

Unbound and hydraulically bound mixtures EN 13286-47

ASTM D1883 – AASHTO T 193 – UNE 103-502 – CNR UNI 10009


Compaction equipment

21. General specifications

Same as the 33-T0063/A EN version except for the complete set which also comprises the 0.1 cm. ft. mould
and the set of two pouring devices.s33-T0063/1
Vibrating table.230 V, 50 Hz, 1 ph.
Weight: 180 kg approx. ors33-T0063/1Z
Vibrating table. 110 V, 60 Hz, 1 ph.Weight: 180 kg approx. ors33-T0063/1Y
Vibrating table. 220 V, 60 Hz, 1 ph.Weight: 180 kg approx.
0.1 cu. ft. relative density mould set
Weight: 37 kg approx.
0.5 cu. ft. relative density mould set
Weight: 106 kg approx.
Relative density gauge set
Weight: 2 kg approx.
Set of two pouring devices,
12.5 and 25 mm dia.
Weight 1.5 kg approx.

This method is used for the laboratory evaluation of subgrade and subbase coarse materials in road
construction. The apparatus comprisesmoulds with accessories, compaction rammers (the automatic models
are the same used for the compaction of Proctor mouldsloading testing machines with accessories, etc.
conforming to the various specifications in useUnbound and hydraulically bound mixtures

22.Dial gauge 25 mm range


0.01 mm. orDial gauge 10 mm range,mm
24. Sodium /Magnesium Sulfate

Specifications

Sodium Sulfate Soundness


Sulfate Soundness
• Provides estimate or index of durability
• Durability
– resistance to weathering
– important in frost‐susceptible regions
• AASHTO T104
– Soundness of Aggregate by Use of Sodium Sulfate orMagnesium Sulfate
– Results different for two sulfates

Material Use Specification Material Use Specification

Used in HMA Surface Courses 15% Max

Used in Structural Concrete 15% Max

Used in Structural 25% Max


Concrete(Marine Limestone)

25. Surcharge weight


26. Dial Gauge
27. Aggregate Crushing Value AGGREGATE / SANDCrushing Value Equipment

System Description
This equipment is used for measuringthe crushing resistance of an aggregate.
Applicable Standards
BS 812-110, 111
It shall be supplied as Standard With:
Cylindrical Cell
Plunger
Base Plate
Tamping Rod, 16mm dia,600mm lengthMetal Measure

Ordering Information:
Crushing Valve Apparatus,150mm as per ISO
Cylindrical Cell
Base Plate
Tamping Rod, 16mm dia,600mm length
Metal Measure
Crushing Valve Apparatus,75mm
.