Ver. 1.9
by
Mahmoud M. El-Kateb, Ph.D
* Project :
Building Data:
Total height of building above foundations 28 m
Total dead load of building 54,740 kN
Total live load of building 8,540 kN
Building importance gI 1.00 Normal building
Building damping factor h 1.00 Reinforced concrete
Response modification factor R 5.0
Building is in area of type 1 Response spectrum curve
Building in seismic zone 2 ag = 0.125 g
Type of soil beneath C S TB TC TD
1.50 0.10 0.25 1.20
Sd (T) = 0.026 g
Earthquake force:
Live load ratio y = 0.25 Residential structures
Weight of building = 56,875 kN
Correction factor l = 1.00
* Project :
Building Data:
Total height of building above foundations 28 m
Total dead load of building 54,740 kN
Total live load of building 8,540 kN
Building importance gI 1.0 Normal building
Building damping factor h 1.0 Reinforced concrete
Response modification factor R 5.0
Building is in area of type 1 Response spectrum curve
Building in seismic zone 2 ag = 0.125 g
Type of soil beneath C S TB TC TD
1.50 0.10 0.25 1.20
T (S) 0.000 0.033 0.067 0.100 0.150 0.200 0.250 0.440 0.630
Sd (m/s ) 1.2263 1.1241 1.0219 0.9197 0.9197 0.9197 0.9197 0.5225 0.3650
2
T (S) 0.820 1.010 1.200 1.667 2.133 2.600 3.067 3.533 4.000
Sd (m/s ) 0.2804 0.2453 0.2453 0.2453 0.2453 0.2453 0.2453 0.2453 0.2453
2
1.40
1.20
1.00
0.80
0.60
0.40
0.20
0.00
0.00 0.20 0.40 0.60 0.80 1.00 1.20 1.40 1.60 1.80 2.00 2.20 2.40 2.60 2.80 3.00 3.20 3.40 3.60 3.80 4.00
Time (Sec.)
Type 1 - Seismic zone (3) - Soil type (C) , gI = 1.0 , h = 1.0 , R = 5.0