You are on page 1of 17

MAIN CON TRACTOR: CONSULTANT

CONSULTANT: CLIENT: SUB CONTRACTOR:

SAJAN RIZWAN
ASKERALI

PROJECT:
Proposed B+LG+G+ 7+ R Commercial Residential Developments on Plot No. IC1-
IC1- REF: HFC-
DXB/p1966/CFC-001
CTYL-01_09AB
01_09AB at International City, Dubai -UAE
Rev.: 00
Document Title : Carbon Fiber Calculations
Date: 27th June 2021

Project : Proposed B+LG+G+ 7+ R Commercial Residential


Developments on Plot No. IC1-CTYL-01_09AB
IC1 01_09AB at International City, Dubai -UAE

Client : Mr. Sajan Rizwan Askerali

Engineer / Consultant : M/s National Engineering Bureau (NEB)

Main Contractor : M/s M/s Gulf Asia Contracting Co. LLC

Sub – Contracor : High Force Concrete LLC

Document Title :

Carbon Fiber Calculations

Prepared by: Engr. Mohamed Ezzat Signature: Date: 01st June 2021
Design Director

Reviewed by: Signature: Date:

Reviewed by: Signature: Date:


COOLING
TOWER 33.800 SSL
34.550 SSL
34.550 SSL

CHILLER
PLANT

PART A PART B
33.800 SSL

34.000 FFL
33.800 SSL

PART D PART C
34.550 SSL
34.000 FFL 33.800 SSL
34.550 SSL

PL1 A B C D E F G H J K L M N P Q R

FOR SECTION &BEAM DETAILS REFER TO


CONSULTANT'S APPROVED STRUCT. Dwgs
1
LEGEND & ABBREVIATION

POURSTRIP 1000mm
SLAB LEGEND:
2

1500

3000 3000

2800
A
3

3900

3900
A A

POURSTRIP 1000mm

7800
POURSTRIP 1000mm

A SEC 1

2500

5
1400

SAJAN RIZWAN ASKERALI


POURSTRIP 1000mm

INTERNATIONAL CITY LLC

B+LG+G+7+R COMMERCIAL
RESIDENTIAL DEVELOPMENT
A

2800

LAWNZ BY DANUBE
6
1400

2700
DN
A

2500

2400
A

7
1400

FO
R C E C ON
C H.F.C CONSTRUCTION SYSTEMS

R
HIGH FORCE CONCRETE

ET
HI

E
TeL: 06-5747778. Fax: 0
TeL: 04-2394133.
CONSTRUCTION SYSTEMS P.O.Box:
E-mail:hfcuae@hfcpt.com

AESF-1335

GROUND FLOOR SLAB PART-A


STRENGTHENING PLAN

---------------- 00
COOLING
TOWER 33.800 SSL
34.550 SSL
34.550 SSL

CHILLER
PLANT

PART A PART B
33.800 SSL

34.000 FFL
33.800 SSL

PART D PART C
34.550 SSL
34.000 FFL 33.800 SSL
34.550 SSL

R RR QQ PP NN MM LL KK JJ HH GG FF EE DD CC BB AA

FOR SECTION &BEAM DETAILS REFER TO


CONSULTANT'S APPROVED STRUCT. Dwgs

LEGEND & ABBREVIATION

SLAB LEGEND:

POURSTRIP 1000mm
DN
2

2900

2700

3
3800

A
3900

A
POURSTRIP 1000mm
POURSTRIP 1000mm

A
10000

6000

2500
6150

SEC 2

SEC 3

5000

A
5100
SAJAN RIZWAN ASKERALI
5

3500

1830
B
INTERNATIONAL CITY LLC

B+LG+G+7+R COMMERCIAL
RESIDENTIAL DEVELOPMENT
LAWNZ BY DANUBE
POURSTRIP 1000mm

FO
R C E C ON
C H.F.C CONSTRUCTION SYSTEMS

R
HIGH FORCE CONCRETE

ET
HI
7

E
TeL: 06-5747778. Fax: 0
TeL: 04-2394133.
CONSTRUCTION SYSTEMS P.O.Box:
E-mail:hfcuae@hfcpt.com

AESF-1335

GROUND FLOOR SLAB PART-B


STRENGTHENING PLAN

---------------- 00
COOLING
TOWER 33.800 SSL
34.550 SSL
34.550 SSL

CHILLER
PLANT

PART A PART B
7 34.000 FFL
33.800 SSL

33.800 SSL

PART D PART C
34.550 SSL
34.000 FFL 33.800 SSL
34.550 SSL

FOR SECTION &BEAM DETAILS REFER TO


DN CONSULTANT'S APPROVED STRUCT. Dwgs

LEGEND & ABBREVIATION


9

POURSTRIP 1000mm
3000

SLAB LEGEND:

SEC 4
10
POURSTRIP 1000mm

3000
A

3000

11
3800

4000
A

12

POURSTRIP 1000mm
13 SAJAN RIZWAN ASKERALI

INTERNATIONAL CITY LLC

B+LG+G+7+R COMMERCIAL
RESIDENTIAL DEVELOPMENT
LAWNZ BY DANUBE

14
POURSTRIP 1000mm POURSTRIP 1000mm

FO
R C E C ON
C H.F.C CONSTRUCTION SYSTEMS

R
HIGH FORCE CONCRETE

ET
HI

E
TeL: 06-5747778. Fax: 0
TeL: 04-2394133.
CONSTRUCTION SYSTEMS P.O.Box:
E-mail:hfcuae@hfcpt.com

R RR QQ PP NN MM LL KK JJ HH GG FF EE DD CC BB AA
AESF-1335

GROUND FLOOR SLAB PART-C


STRENGTHENING PLAN

---------------- 00
H.F.C Prestressing Cont.

Date: 3/12/2018 Project: Eng.

STRUCTURAL STRENGTHENING DESIGN


FLOOR NO: GR FLOOR
SECTION NO:

The ultimate stress in the required CFRP can be used as ffe = 0.005 x Ef according to the
ACI 440-2008 then:
Capacity in case of steel bars = Mns = As fy (d – b 1 c/2) = 0.9 As fy
Capacity in case of CFRP = Mnf = Af ffe (de – b 1 c/2) = 0.95 Af ffe
Mu = fMn = 0.9 (Mns + 0.85 Mnf)
Then the equivalent 0.9 x 0.9 As fy = 0.9 x 0.85 x 0.95 Af ffe

Material:

f'c = 32 Mpa
Fy = 460 Mpa

FRP Material Properties

USE Recon Plate CFL 100x1.4 mm


thickness tf = 1.4 mm
width wf = 100 mm
ult strength f*fu = 2600 Mpa
rupture strain e*fu = 0.0165
Ef = 160000 Mpa

The anticipated design loads must exceed the existing capacity of un-strengthened member

Resistance of the un-strengthened member in case of fire Mfire=(1.1 MDL+0.75 MLL)

SECTION NO. MDL MLL Mfire Mcapacity Status AS REQ ffe Af No. of plates Plate Length
1 605 500 1041 1200 OK 5500 800 3525 26 4
2 850 550 1348 1660 OK 2850 800 1826 14 4.7
3 665 1220 1647 1820 OK 10000 800 6409 46 4.7
4 605 490 1033 1200 OK 2400 800 1538 11 6.25

SUM LENGTH 454.75


H.F.C Prestressing Cont.

Date: 6/28/2021 Project: 1966 Eng. M.E

STRUCTURAL STRENGTHENING DESIGN REFERENCE ACI 440.2R-08


FLOOR NO: GR FLOOR
SECTION NO: 1

Concrete Dimension:

Thickness (t) = 350 mm


Width (b) = 1000 mm
depth (dP) = 242 mm
depth (d) = 320 mm
depth (d') = 25 mm
flange width (B) = 1000 mm
flange THK (ts) = 0 mm
concrete cover = 25 mm

Material:

f'c = 32 Mpa
Fy = 460 Mpa
strand Dia = 12.7 mm
Aps = 240 mm2
fpe = 1100 Mpa
fpy = 1670 Mpa
fpu = 1860 Mpa
Ep = 195000 Mpa
Rebar Dia = 12 mm
No. Of Rebar = 5
As = 565 mm2
Comp ebar Dia = 12 mm
No. Of Rebar = 5
As' = 565 mm2
Es = 200000 Mpa

FRP Material Properties

thickness tf = 1.4 mm
width wf = 320 mm
ult strength f*fu = 2600 Mpa
rupture strain e*fu = 0.014
Ef = 160000 Mpa
No of ply = 1
Af = 448 mm2
Straining action:

Existing loads
MDL initial = 50 KN.m
Anticipated loads
MDL = 73.7 KN.m
MLL = 61 KN.m
Ms = 134.7 KN.m
MU = 186.04 KN.m
Fire loads
MU (1.1 MDL+0.75 MLL = 126.82 KN.m
Moment capacity
Mcap = 193 KN.m

Analysis:

Calculate the FRP-system design material properties


ffu =CE f*fu = 2470 Mpa
efu =CE e*fu = 0.0133

Properties of the concrete


1 = 0.82
fr = 3.51 Mpa
Ec = 26587 Mpa
Acg = 3.5E+05 mm2
yt = 175 mm
yb = 175 mm
Ig = 3.6E+09 mm2
Radius of gyration r = 101 mm
Effective prestrssing strain epe = 0.00564
Effective prestressing force Pe = 2.6E+05 N
Eccentricity of prestressing force e = 67 mm

Determine the existing state of strain on the soffit


initial strain in the soffit ebi = 3.1E-05

Determine the design strain in the FRP system


Strain of FRP efd = 0.0049 < 0.0120 (0.9 efu)
Strain of FRP efd = 0.0049

Estimate c , the depth to neutral axis


c initial estimate 0.1 h = 68.0 mm refer to step 10

Determine the effective level of strain in the FRP reinforcement


Strain of FRP efe = 0.0124 > 0.0049 (efd)
Strain of FRP efe = 0.0049

Calculate the strain in the existing prestressing & normal steel


epnet = 0.0030
Strain of prestressing steel eps = 0.0087 < 0.0350
Strain of prestressing steel eps = 0.0087
Strain of normal steel es = 0.0044
Strain of normal steel e's = 0.0008
Calculate the stress level in the prestressing steel and FRP
fps = 1,700 Mpa
ffe = 784 Mpa
fs = 460 Mpa
f's = 150 Mpa

Calculate the equivalent concrete compressive stress


ec = 0.0012
e'c = 0.0020
1 = 0.71
a1 = 0.66

Calculate the internal force rusultants and check equilibrium


c = 68.0 mm

Calculate the flexural strength components


Prestressing steel ……………...……...…..…...Mnp = 89 KN-m
Tension reinforcement steel ………….….…...Mns = 77 KN-m Mucap > Mu fire SAFE
Compression reinforcement steel ……..….....Mns = 25 KN-m
FRP ……………………….……………..……….Mnf = 115 KN-m
Flexural strength of the section ………………fMn = 260 KN-m >Mu

Check service stress in the FRP reinforcement


ffs = 34.72 Mpa < 0.55ffu 1359 Mpa

Check development length


ldf = 199 mm

Check service condition of the section


Cracking moment ……………...……...…..…...Mcr = 94 KN-m < Mservice

Check stress in prestressing steel


eps,s = 0.0057 < 0.0086
fps,s = 1,116 Mpa < 0.82fpy & < 0.74fpu

Check stress in concrete


ec,s = 0.00004
fc,s = 1.09 Mpa < 0.45f'c
H.F.C Prestressing Cont.

Date: 6/28/2021 Project: 1966 Eng. M.E

STRUCTURAL STRENGTHENING DESIGN REFERENCE ACI 440.2R-08


FLOOR NO: GR FLOOR
SECTION NO: 2

Concrete Dimension:

Thickness (t) = 350 mm


Width (b) = 1000 mm
depth (dP) = 240 mm
depth (d) = 320 mm
depth (d') = 25 mm
flange width (B) = 1000 mm
flange THK (ts) = 0 mm
concrete cover = 25 mm

Material:

f'c = 32 Mpa
Fy = 460 Mpa
strand Dia = 12.7 mm
Aps = 175 mm2
fpe = 1100 Mpa
fpy = 1670 Mpa
fpu = 1860 Mpa
Ep = 195000 Mpa
Rebar Dia = 12 mm
No. Of Rebar = 5
As = 565 mm2
Comp ebar Dia = 10 mm
No. Of Rebar = 5
As' = 393 mm2
Es = 200000 Mpa

FRP Material Properties

thickness tf = 1.4 mm
width wf = 140 mm
ult strength f*fu = 2600 Mpa
rupture strain e*fu = 0.014
Ef = 160000 Mpa
No of ply = 1
Af = 196 mm2
Straining action:

Existing loads
MDL initial = 40 KN.m
Anticipated loads
MDL = 80.9 KN.m
MLL = 51 KN.m
Ms = 131.9 KN.m
MU = 178.68 KN.m
Fire loads
MU (1.1 MDL+0.75 MLL) = 127.24 KN.m
Moment capacity
Mcap = 159 KN.m

Analysis:

Calculate the FRP-system design material properties


ffu =CE f*fu = 2470 Mpa
efu =CE e*fu = 0.0133

Properties of the concrete


1 = 0.82
fr = 3.51 Mpa
Ec = 26587 Mpa
Acg = 3.5E+05 mm2
yt = 175 mm
yb = 175 mm
Ig = 3.6E+09 mm2
Radius of gyration r = 101 mm
Effective prestrssing strain epe = 0.00564
Effective prestressing force Pe = 1.9E+05 N
Eccentricity of prestressing force e = 65 mm

Determine the existing state of strain on the soffit


initial strain in the soffit ebi = 3.0E-05

Determine the design strain in the FRP system


Strain of FRP efd = 0.0049 < 0.0120 (0.9 efu)
Strain of FRP efd = 0.0049

Estimate c , the depth to neutral axis


c initial estimate 0.1 h = 58.7 mm refer to step 10

Determine the effective level of strain in the FRP reinforcement


Strain of FRP efe = 0.0149 > 0.0049 (efd)
Strain of FRP efe = 0.0049

Calculate the strain in the existing prestressing & normal steel


epnet = 0.0031
Strain of prestressing steel eps = 0.0087 < 0.0350
Strain of prestressing steel eps = 0.0087
Strain of normal steel es = 0.0044
Strain of normal steel e's = 0.0005
Calculate the stress level in the prestressing steel and FRP
fps = 1,701 Mpa
ffe = 784 Mpa
fs = 460 Mpa
f's = 108 Mpa

Calculate the equivalent concrete compressive stress


ec = 0.0010
e'c = 0.0020
1 = 0.70
a1 = 0.58

Calculate the internal force rusultants and check equilibrium


c = 54.6 mm

Calculate the flexural strength components


Prestressing steel ……………...……...…..…...Mnp = 66 KN-m
Tension reinforcement steel ………….….…...Mns = 78 KN-m Mucap > Mu fire SAFE
Compression reinforcement steel ……..….....Mns = 13 KN-m
FRP ……………………….……………..……….Mnf = 51 KN-m
Flexural strength of the section ………………fMn = 180 KN-m >Mu

Check service stress in the FRP reinforcement


ffs = 34.09 Mpa < 0.55ffu 1359 Mpa

Check development length


ldf = 199 mm

Check service condition of the section


Cracking moment ……………...……...…..…...Mcr = 87 KN-m < Mservice

Check stress in prestressing steel


eps,s = 0.0057 < 0.0086
fps,s = 1,114 Mpa < 0.82fpy & < 0.74fpu

Check stress in concrete


ec,s = 0.00003
fc,s = 0.78 Mpa < 0.45f'c
H.F.C Prestressing Cont.

Date: 6/28/2021 Project: 1966 Eng. M.E

STRUCTURAL STRENGTHENING DESIGN REFERENCE ACI 440.2R-08


FLOOR NO: GR FLOOR
SECTION NO: 3

Concrete Dimension:

Thickness (t) = 350 mm


Width (b) = 1000 mm
depth (dP) = 250 mm
depth (d) = 320 mm
depth (d') = 25 mm
flange width (B) = 1000 mm
flange THK (ts) = 0 mm
concrete cover = 25 mm

Material:

f'c = 32 Mpa
Fy = 460 Mpa
strand Dia = 12.7 mm
Aps = 180 mm2
fpe = 1100 Mpa
fpy = 1670 Mpa
fpu = 1860 Mpa
Ep = 195000 Mpa
Rebar Dia = 12 mm
No. Of Rebar = 5
As = 565 mm2
Comp ebar Dia = 10 mm
No. Of Rebar = 5
As' = 393 mm2
Es = 200000 Mpa

FRP Material Properties

thickness tf = 1.4 mm
width wf = 420 mm
ult strength f*fu = 2600 Mpa
rupture strain e*fu = 0.014
Ef = 160000 Mpa
No of ply = 1
Af = 588 mm2
Straining action:

Existing loads
MDL initial = 50 KN.m
Anticipated loads
MDL = 60.4 KN.m
MLL = 111 KN.m
Ms = 171.4 KN.m
MU = 250.08 KN.m
Fire loads
MU (1.1 MDL+0.75 MLL) = 149.69 KN.m
Moment capacity
Mcap = 168 KN.m

Analysis:

Calculate the FRP-system design material properties


ffu =CE f*fu = 2470 Mpa
efu =CE e*fu = 0.0133

Properties of the concrete


1 = 0.82
fr = 3.51 Mpa
Ec = 26587 Mpa
Acg = 3.5E+05 mm2
yt = 175 mm
yb = 175 mm
Ig = 3.6E+09 mm2
Radius of gyration r = 101 mm
Effective prestrssing strain epe = 0.00564
Effective prestressing force Pe = 2.0E+05 N
Eccentricity of prestressing force e = 75 mm

Determine the existing state of strain on the soffit


initial strain in the soffit ebi = 4.3E-05

Determine the design strain in the FRP system


Strain of FRP efd = 0.0049 < 0.0120 (0.9 efu)
Strain of FRP efd = 0.0049

Estimate c , the depth to neutral axis


c initial estimate 0.1 h = 68.3 mm refer to step 10

Determine the effective level of strain in the FRP reinforcement


Strain of FRP efe = 0.0123 > 0.0049 (efd)
Strain of FRP efe = 0.0049

Calculate the strain in the existing prestressing & normal steel


epnet = 0.0032
Strain of prestressing steel eps = 0.0089 < 0.0350
Strain of prestressing steel eps = 0.0089
Strain of normal steel es = 0.0044
Strain of normal steel e's = 0.0008
Calculate the stress level in the prestressing steel and FRP
fps = 1,712 Mpa
ffe = 784 Mpa
fs = 460 Mpa
f's = 152 Mpa

Calculate the equivalent concrete compressive stress


ec = 0.0012
e'c = 0.0020
1 = 0.71
a1 = 0.67

Calculate the internal force rusultants and check equilibrium


c = 68.2 mm

Calculate the flexural strength components


Prestressing steel ……………...……...…..…...Mnp = 70 KN-m
Tension reinforcement steel ………….….…...Mns = 77 KN-m Mucap > Mu fire SAFE
Compression reinforcement steel ……..….....Mns = 18 KN-m
FRP ……………………….……………..……….Mnf = 150 KN-m
Flexural strength of the section ………………fMn = 263 KN-m >Mu

Check service stress in the FRP reinforcement


ffs = 43.56 Mpa < 0.55ffu 1359 Mpa

Check development length


ldf = 199 mm

Check service condition of the section


Cracking moment ……………...……...…..…...Mcr = 89 KN-m < Mservice

Check stress in prestressing steel


eps,s = 0.0057 < 0.0086
fps,s = 1,115 Mpa < 0.82fpy & < 0.74fpu

Check stress in concrete


ec,s = 0.00003
fc,s = 0.88 Mpa < 0.45f'c
H.F.C Prestressing Cont.

Date: 6/28/2021 Project: 1966 Eng. M.E

STRUCTURAL STRENGTHENING DESIGN REFERENCE ACI 440.2R-08


FLOOR NO: GR FLOOR
SECTION NO: 4

Concrete Dimension:

Thickness (t) = 350 mm


Width (b) = 1000 mm
depth (dP) = 300 mm
depth (d) = 320 mm
depth (d') = 25 mm
flange width (B) = 1000 mm
flange THK (ts) = 0 mm
concrete cover = 25 mm

Material:

f'c = 32 Mpa
Fy = 460 Mpa
strand Dia = 12.7 mm
Aps = 218 mm2
fpe = 1100 Mpa
fpy = 1670 Mpa
fpu = 1860 Mpa
Ep = 195000 Mpa
Rebar Dia = 12 mm
No. Of Rebar = 5
As = 565 mm2
Comp ebar Dia = 10 mm
No. Of Rebar = 5
As' = 393 mm2
Es = 200000 Mpa

FRP Material Properties

thickness tf = 1.4 mm
width wf = 151 mm
ult strength f*fu = 2600 Mpa
rupture strain e*fu = 0.014
Ef = 160000 Mpa
No of ply = 1
Af = 211.4 mm2
Straining action:

Existing loads
MDL initial = 52 KN.m
Anticipated loads
MDL = 83 KN.m
MLL = 67.5 KN.m
Ms = 150.5 KN.m
MU = 207.6 KN.m
Fire loads
MU (1.1 MDL+0.75 MLL) = 141.925 KN.m
Moment capacity
Mcap = 200 KN.m

Analysis:

Calculate the FRP-system design material properties


ffu =CE f*fu = 2470 Mpa
efu =CE e*fu = 0.0133

Properties of the concrete


1 = 0.82
fr = 3.51 Mpa
Ec = 26587 Mpa
Acg = 3.5E+05 mm2
yt = 175 mm
yb = 175 mm
Ig = 3.6E+09 mm2
Radius of gyration r = 101 mm
Effective prestrssing strain epe = 0.00564
Effective prestressing force Pe = 2.4E+05 N
Eccentricity of prestressing force e = 125 mm

Determine the existing state of strain on the soffit


initial strain in the soffit ebi = 1.5E-05

Determine the design strain in the FRP system


Strain of FRP efd = 0.0049 < 0.0120 (0.9 efu)
Strain of FRP efd = 0.0049

Estimate c , the depth to neutral axis


c initial estimate 0.1 h = 60.5 mm refer to step 10

Determine the effective level of strain in the FRP reinforcement


Strain of FRP efe = 0.0143 > 0.0049 (efd)
Strain of FRP efe = 0.0049

Calculate the strain in the existing prestressing & normal steel


epnet = 0.0041
Strain of prestressing steel eps = 0.0098 < 0.0350
Strain of prestressing steel eps = 0.0098
Strain of normal steel es = 0.0044
Strain of normal steel e's = 0.0006
Calculate the stress level in the prestressing steel and FRP
fps = 1,760 Mpa
ffe = 784 Mpa
fs = 460 Mpa
f's = 121 Mpa

Calculate the equivalent concrete compressive stress


ec = 0.0010
e'c = 0.0020
1 = 0.70
a1 = 0.60

Calculate the internal force rusultants and check equilibrium


c = 60.5 mm

Calculate the flexural strength components


Prestressing steel ……………...……...…..…...Mnp = 107 KN-m
Tension reinforcement steel ………….….…...Mns = 78 KN-m Mucap > Mu fire SAFE
Compression reinforcement steel ……..….....Mns = 14 KN-m
FRP ……………………….……………..……….Mnf = 55 KN-m
Flexural strength of the section ………………fMn = 221 KN-m >Mu

Check service stress in the FRP reinforcement


ffs = 41.99 Mpa < 0.55ffu 1359 Mpa

Check development length


ldf = 199 mm

Check service condition of the section


Cracking moment ……………...……...…..…...Mcr = 96 KN-m < Mservice

Check stress in prestressing steel


eps,s = 0.0057 < 0.0086
fps,s = 1,121 Mpa < 0.82fpy & < 0.74fpu

Check stress in concrete


ec,s = 0.00007
fc,s = 1.73 Mpa < 0.45f'c

You might also like