Professional Documents
Culture Documents
SITE ID : V0045
SITE NAME : WEST SAMAR-MATUGUINAO
AREA : WESTERN SAMAR
PROVINCE : SAMAR
TOWN : SAMAR
BARANGAY : -
SITE DETAILS INDEX
SITE ADDRESS:
DISTANCE FROM
NEAREST AIRPORT: ü
EXPOSURE CLASSIFICATION:
WIND SPEED :
A
STRUCTURAL ENGINEER
PRC NO.: 56173 PTR NO.: 8534870ME B
TIN NO.: 100-317-353 DATE ISSUED: 01-05-2021 PROJECT ADMINISTRATION
C
ISSUED AT: MAKATI CITY
850
N
850
350 550
217°
3 LEGGED
30.0m TOWER HEIGHT 300 550 300
850
900
900
4450
14000
CABIN
1000 900
20000
140 1320
3000
3000
I. DESIGN CRITERIA: TOWER INVESTIGATION AND RETROFITTING DESIGN
3000 3000 3000 3000 400 1000 1600
A. DESIGN CODE: NATIONAL STRUCTURAL CODE OF THE PHILIPPINES
AND TIA-222-G
B. DESIGN LOADS 1 SITE DEVELOPMENT PLAN
SCALE 1:100MTS
EXPOSURE B 1/5
SURVIVAL 3 SEC. GUST WIND SPEED - 320 KPH (NSCP 2015 7TH EDITION)
C. DEFLECTION LIMITATION
A
STRUCTURAL ENGINEER
PRC NO.: 56173 PTR NO.: 8534870ME B
TIN NO.: 100-317-353 DATE ISSUED: 01-05-2021 PROJECT ADMINISTRATION
C
ISSUED AT: MAKATI CITY
PANEL-05 PANEL-04 PANEL-03 PANEL-02 PANEL-01 NO. OF PANEL
5"Ø NPS PIPE (141.300mm O.D) 6"Ø NPS PIPE (168.275mm O.D) 7"Ø NPS PIPE (193.675mm O.D) 10"Ø NPS PIPE (273.050mm O.D) MAIN TOWER LEG
3"Ø NPS PIPE (88.9mm O.D.) w/ 2-16Ø BOLT 3"Ø NPS PIPE (88.9mm O.D.) w/ 2-20Ø BOLT 3 1/2"Ø NPS PIPE (101.600mm O.D) W/ 2-20mmØ BOLT MAIN DIAGONAL
DETAIL-02
DETAIL-01
2000
4450
SP-04
SCALE
SP-03
SP-02
SP-01
2/6
1
2000 2000 2000 2000 2000 2000 2000 2000 2000 3000 3000 3000 3000
30000 EXISITING TOWER HEIGHT
ANTENNA CONFIGURATION
EXISTING ANTENNA
EXPANDED WIRE
EA 50x8mm THK
12 RRU 28.0 RRU 0.400x0.300x0.100 25.0 - AMB EXISTING
MESH
EXISTING FEEDER CABLE
1:120MTS
SECTION 'A'
PROPOSED ANTENNA
PA2 28.0 2.3MM (MIMO) 0.965x0.470 x0.160 35 MAX A PROPOSED MATERIAL STRENGTH USE FOR STRUCTURAL STEEL ASSUMED TO HAVE COMPLY
WITH INTERNATIONALLY RECOGNIZED STANDARDS AND HAVE THE FOLLOWING
SCALE
PA2 28.0 2.3MM (MIMO) 0.965x0.470 x0.160 35 MAX B PROPOSED MINIMUM YIELD STRENGTH.
PA2 28.0 2.3MM (MIMO) 0.965x0.470 x0.160 35 MAX C PROPOSED 1. ALL STRUCTURAL STEEL ASSUMED TO HAVE MINIMUM YIELD STRENGTH OF
2/6
THE FOLLOWING.
2
MW LEG (C) 25.0 MW Ø 1.2 50 MAX
- C PROPOSED
TOWER LEG fy=241 MPa
FUTURE ANTENNA HORIZONTAL fy=241 MPa
DIAGONAL fy=241 MPa
ELEV. DMENSION (M) WEIGHT OTHERS fy=248 MPa
DESIGNATION (M)
TYPE
(KG) ORIENTIATION LEG REMARKS
HxWxD
2. STRUCTURAL STEEL PLATE ASSUMED TO HAVE MINIMUM YIELD STRENGTH
PA3 29.0 2.6GMM (MIMO) 0.965x0.470 x0.195 35 MAX A FUTURE OF 248 MPA.
3. STRUCTURAL CONNECTION BOLTS ASSUMED TO CONFORM TO ASTM A325.
PA3 29.0 2.6GMM (MIMO) 0.965x0.470 x0.195 35 MAX B FUTURE 4. STEEL SHALL BE GALVANIZED IN ACCORDANCE WITH ASTM A123,
HOT-DIPPED 85 MICRON
PA3 29.0 2.6GMM (MIMO) 0.965x0.470 x0.195 35 MAX C FUTURE 5. WELDING SHALL CONFORM TO AWS STRUCTURAL WELDING CODE-STEEL
USING E70xx ELECTRODES OR EQUIVALENT.
PA4 29.0 3.5GMM (MIMO) 0.730x0.395 x0.160 27 MAX B FUTURE 6. SITE WELD SHOULD BE ZINGA PAINT FINISHED.
7. CONCRETE MUST HAVE A MINIMUM COMPRESSIVE STRENGTH
PA4 29.0 3.5GMM (MIMO) 0.730x0.395 x0.160 27 MAX C FUTURE OF 21 MPA (3000 PSI).
A
STRUCTURAL ENGINEER
PRC NO.: 56173 PTR NO.: 8534870ME B
TIN NO.: 100-317-353 DATE ISSUED: 01-05-2021 PROJECT ADMINISTRATION
C
ISSUED AT: MAKATI CITY
450 450 360 300
88 273 88 128 194 128 96 168 96 79 141 79
6-26mmØ 6-20mmØ 6-20mmØ 6-20mmØ
SPLICE BOLT SPLICE BOLT SPLICE BOLT SPLICE BOLT
88
128
450Øx20mm THK. 450Øx20mm THK. 360Øx20mm THK. 300Øx20mm THK.
96
79
SPLICE PLATE SPLICE PLATE SPLICE PLATE SPLICE PLATE
220x190x12mm THK. 220x190x12mm THK.
450
450
141
220x190x12mm THK.
273
360
300
194
168
220x190x12mm THK.
GUSSET PLATE GUSSET PLATE GUSSET PLATE
GUSSET PLATE
10"Ø NPS PIPE
79
7"Ø NPS PIPE
96
6"Ø NPS PIPE 5"Ø NPS PIPE
128
(273.050mm O.D) (193.675mm O.D)
88
200x90x10mm
THK. STIFFENER
200x90x10mm PLATE
THK. STIFFENER
6"Ø NPS PIPE 5"Ø NPS PIPE
PLATE 7"Ø NPS PIPE
(168.275mm O.D) (141.300mm O.D)
(193.675mm O.D)
10"Ø NPS PIPE
200x100x8mm THK. 200x80x8mm THK.
(273.050mm O.D)
3 1/2"Ø NPS PIPE STIFFENER PLATE STIFFENER PLATE
3"Ø NPS PIPE
(101.600mm O.D) 3"Ø NPS PIPE 3"Ø NPS PIPE
(88.9mm O.D.)
W/ (88.9mm O.D.) (88.9mm O.D.)
2-20mmØ BOLTS
2-20mmØ BOLT 2-20mmØ BOLTS 2-16mmØ BOLTS
MAIN LEG
10"Ø NPS PIPE
(273.050mm O.D)
MAIN LEG
MAIN DIAGONAL
3 1/2"Ø NPS PIPE
(101.600mm O.D)
W/ 2-20mmØ BOLT
460x220x10mm THK
GUSSET PLATE
520x220x16mm THK
GUSSET PLATE
MAIN DIAGONAL
3 1/2"Ø NPS PIPE
(101.600mm O.D)
W/ 2-20mmØ BOLT
A
STRUCTURAL ENGINEER
PRC NO.: 56173 PTR NO.: 8534870ME B
TIN NO.: 100-317-353 DATE ISSUED: 01-05-2021 PROJECT ADMINISTRATION
C
ISSUED AT: MAKATI CITY
850
180 490 180
6-26mmØ
180
ANCHOR BOLT
108.5
490mmØx24mm THK. TOP PLATE
490
850
273
10"Ø NPS. PIPE (273.050mm O.D)
MAIN LEG
108.5
PLATE
180
850x850x700mm
CONCRETE PEDESTAL
PLAN
490mmØx24mm THK.
BOTTOM PLATE
850x850x700mm
CONCRETE PEDESTAL
700
ELEVATION
4 PEDESTAL DETAIL
SCALE
4/5 1:20M
A
STRUCTURAL ENGINEER
PRC NO.: 56173 PTR NO.: 8534870ME B
TIN NO.: 100-317-353 DATE ISSUED: 01-05-2021 PROJECT ADMINISTRATION
C
ISSUED AT: MAKATI CITY
2 SITE PHOTOS
5/5 SCALE NTS
1 TOWER PHOTOS
5/5 SCALE NTS
A
STRUCTURAL ENGINEER
PRC NO.: 56173 PTR NO.: 8534870ME B
TIN NO.: 100-317-353 DATE ISSUED: 01-05-2021 PROJECT ADMINISTRATION
C
ISSUED AT: MAKATI CITY
2000
2000
2000
BILL OF MATERIALS
QTY. DIMENSION TOTAL
MARK MATERIAL
2000 (pcs.) (mm) WEIGHT (KG.)
MD-01 4" Ø NPS PIPE (114.30 O.D.) 3 5000 253.99
EXISTING MD-02 4" Ø NPS PIPE (114.30 O.D.) 3 4800 243.83
10" Ø NPS PIPE
CP-01 10mm THK. PLATE 12 136x220 28.12
2000
(273.050mm O.D.)
MAIN LEG CB-01 16mm Ø CONNECTOR BOLT 24 100 6.35
TOTAL KG. 532.29
PROPOSED
4" Ø NPS PIPE
(114.30mm O.D)
2000
W/ 2-16mmØ BOLT
(MD-02) WEIGHT COMPARISON
BEFORE RETRO 5752.91 kg.
2000
2000
PROPOSED
4" Ø NPS PIPE
(114.30mm O.D)
W/ 2-16mmØ BOLT
2000
(MD-01)
2000
2 DETAIL-01
6/6 SCALE 1:20M
2400
220
GENERAL NOTES:
30 60 50 80
6 1. ALL DIMENSIONS ARE IN MILLIMETERS AND ALL LEVELS ARE IN METERS
2400
TYP.
6 UNLESS OTHERWISE NOTED. DIMENSIONS ARE NOT TO BE OBTAINED BY
SCALING.
136
BRACING TO 4" Ø NPS PIPE (114.30mm O.D.)
DESIGNER/CONSULTANT.
10mm THK. PROPOSED
2-16mm Ø BOLTS
CONNECTOR PLATE 4"Ø NPS PIPE
(CB-01) 3. VERIFY ACTUAL SITE CONDITION AND DIMENSIONS BEFORE FABRICATION
(CP-01) (114.30mm O.D.)
DETAIL-01 WORKS AND SEEK APPROVAL FROM SMART ENGINEER OR SMART
PROPOSED
4" Ø MAIN DIAGONAL CONSULTANT BEFORE COMMENSING THE WORKS. IT SHALL BE THE
RESPONSIBILITY OF THE FABRICATOR TO CHECK ALL THE DIMENSIONS AND
QUANTITIES PRIOR TO EXECUTION OF ALL FABRICATED WORKS.
3 DETAIL CP-01
3000
SCALE 1:10M
6/6 4. ALL DISCREPANCIES SHALL BE REFERRED TO THE CONSULTANT FOR THE
DECISIONS BEFORE PROCEEDING THE WORKS.
4450
A
STRUCTURAL ENGINEER
PRC NO.: 56173 PTR NO.: 8534870ME B
TIN NO.: 100-317-353 DATE ISSUED: 01-05-2021 PROJECT ADMINISTRATION
C
ISSUED AT: MAKATI CITY
GALVANIZED WEIGHT = 473.24 kg
6226.15