Scope
These guidelines apply specifically to the use of
TenarisHydril Blue® Near Flush connections. In the specific
cases of connections with Tenaris dope-free technologies,
this document addresses products sold and marked

CONNECTION SPECIFIC RUNNING GUIDELINES


as Dopeless® and does not address the use of versions
identified as Dopeless® 3.0 or Dopeless® 3.1. If the
product has been procured with any of these newer
IDM Code GDL00273/5 / March 2022

versions please contact our regional Technical Sales team.

This document should be used in conjunction with


the TenarisHydril Running Manual, which is the main
document applicable to the running of all TenarisHydril
premium connections.

Tenaris Field Service Representatives can modify these


guidelines when circumstances dictate. Implementation
will only occur if the representative deems the
modification to be non-detrimental to product integrity.
All modifications need to be clearly explained and agreed
with the client representative prior to implementation
and fully documented in the running report.
RUNNING MANUAL

References
.TenarisHydril Running Manual.
.Premium Connection Approved Thread Compounds
.FTD29356.
TenarisHydril

Recommended guidelines for the field inspection of

.TenarisHydril Blue Near Flush Lift Plug TSH-BD-26.0002.


TenarisHydril connections, GDL31457.
®

1
Equipment, Material & Documents
TenarisHydril Blue® Near Flush Connection

1. Verify the appropriate thread compound is available.

2. Refer to document FTD29356 for a list of


compounds approved by Tenaris.

3. Latest version of the specific Product Data Sheet can be


obtained from Tenaris website. In case this is unavailable,
request the data sheet from the local Technical Sales
representative or contact-tenarishydril@tenaris.com.

Pre-Running
CONNECTION SPECIFIC RUNNING GUIDELINES

1. Care must be exercised when transporting and


handling Blue® Near Flush connections, like any flush or
near flush connection they are susceptible to damage if
uncontrolled contact with any solid object occurs.

2. Never move or handle pipe without the correct


thread protectors securely in place.

3. Ensure connections are cleaned and free of all debris


and / or contaminants, cleaning methods employed
should conform to the recommendations contained
within the TenarisHydril Running Manual.

4. Verify all pipe and accessories have genuine


TenarisHydril manufactured connections.

5. Visually inspect threads and seal areas prior to


RUNNING MANUAL

running, ensuring no damage is evident.

6. On Dopeless® Technology connections check


condition of both pin and box coating ensuring no peel
off or degradation has occurred.
TenarisHydril

7. Verify the compatibility of the TenarisHydril Blue®


Near Flush connection with any accessories such as
cement heads, safety valves, cross overs, etc.
2
8. Verify material grade of all accessories ensuring

TenarisHydril Blue® Near Flush Connection


compatibility with main string.

9. Check availability of handling plugs, 3 as a minimum


to allow operation flow, ensure they are genuine
TenarisHydril manufactured.

10. Check the handling plugs are in good condition


and fit correctly onto the pipe.

11. Check single joint elevators have sufficient


clearance to slide over the box expanded area and seat
against the handling plug.

CONNECTION SPECIFIC RUNNING GUIDELINES


12. Never exceed the maximum lift capacity of the
handling plug, stamped on the plug flange.
IDM Code GDL00273/5 / March 2022

13. Refer to the TenarisHydril running manual for the


care and use of handling / lift plugs.

14. TenarisHydril Blue® Near Flush connections are


a weight specific design therefore connections and
handling plugs are not interchangeable between
different weights of the same OD.

Inspection
1. Inspection criteria for all TenarisHydril connections
is as outlined in the Field Service Operative Guideline
GDL31457.
RUNNING MANUAL

2. Pay particular attention to seal areas.

3. Ensure the pin nose has no tears, gouges or raised


metal.

4. Ensure the pin and box torque shoulders have no


TenarisHydril

dents, tears or raised material which would interfere


with correct assembly.

3
5. Check for mashes or ovality which may have
TenarisHydril Blue® Near Flush Connection

occurred during transportation or storage.

Blue® Near Flush Configuration


HOOKED THREAD
CONNECTION SPECIFIC RUNNING GUIDELINES
RUNNING MANUAL
TenarisHydril

4
IDM Code GDL00273/5 / March 2022

DOPE POCKET

INTERNAL SEAL
EXTERNAL SEAL

TORQUE SHOULDER

5
TenarisHydril RUNNING MANUAL CONNECTION SPECIFIC RUNNING GUIDELINES TenarisHydril Blue® Near Flush Connection
Thread Compound Application
TenarisHydril Blue® Near Flush Connection
CONNECTION SPECIFIC RUNNING GUIDELINES

1. Apply a thin coating of thread compound on the pin


connection, fully covering all threads, seals, pin nose and
torque shoulder, the thread form should be fully visible.

2. Apply a thin coating of thread compound on the


box seals.

3. Do not fill the box dope pocket.

4. Use Tenaris approved thread compounds and apply


the friction factor indicated in FTD29356.
RUNNING MANUAL
TenarisHydril

6
Thread Lock Application

TenarisHydril Blue® Near Flush Connection


CONNECTION SPECIFIC RUNNING GUIDELINES
IDM Code GDL00273/5 / March 2022

Connections must be clean and dry when applying


thread lock

1. Apply a thin coating of thread lock to the first 50%


of each thread section.

2. Do not apply thread lock on the seals or torque


shoulder.

3. Apply thread compound to the pin external seal.

4. Apply thread compound to the box internal seal and


torque shoulder.
RUNNING MANUAL

5. Do not fill the dope pocket.

6. Apply the thread lock manufacturers indicated


friction factor.
TenarisHydril

7
Blue® Near Flush Dopeless® Technology
TenarisHydril Blue® Near Flush Connection
CONNECTION SPECIFIC RUNNING GUIDELINES

1. Minor rust or discolouring of the pin connection can


be removed with the use of a clean, dry rag ensuring
the Dopeless® Technology coating remains intact.

2. Minor rust or discolouring of the box connection


can be removed with the use of a non abrasive
plastic scouring pad and a clean, dry rag ensuring the
Dopeless® Technology coating remains intact.

3. Dopeless® Technology connections do not require


the application of thread compound for make up.

4. If for whatever reason thread compound has to


be applied to Blue® Near Flush Dopeless® Technology
connections, whether both pin and box are Dopeless®
RUNNING MANUAL

Technology or when mixing a doped connection with a


Dopeless® Technology, proceed as indicated below.

.Apply a very thin coating of thread compound on all


pin threads, seals and torque shoulder.

.Apply a thin layer of thread compound to the box seals.


TenarisHydril

8
Blue® Near Flush Dopeless® Technology

TenarisHydril Blue® Near Flush Connection


Thread Lock
1. Ideally when running a Dopeless® Technology string
the connections to be thread locked should be the non
Dopeless® Technology variant with the connections
cleaned of thread compound and completely dried,
then thread lock and dope applied as per page 7.

2. When thread locking Dopeless® Technology


connections remove the Dopeless® Technology coating
from the threads on the pin connection where the
thread lock is to be applied.

CONNECTION SPECIFIC RUNNING GUIDELINES


3. Use a hand or rotary brass wire wheel to remove
the Dopeless® Technology coating from the threads,
ensuring no contact is made with the seal.
IDM Code GDL00273/5 / March 2022

4. Leave the Dopeless® Technology coating on the pin


seals, torque shoulder and threads where no thread
lock is to be applied.

5. Dopeless® Technology boxes should be washed with


hot water then dried prior to thread locking.

6. Thread lock should be applied to 50% of the pin


threads of each thread section, as per the diagram on
page 7.

7. The application of thread dope is not required.

8. When assembling Dopeless® Technology


RUNNING MANUAL

connections with thread lock, apply the non


Dopeless® Technology torque values, taken from the
standard product data sheet.

9. Apply the thread lock manufacturers


indicated friction factor.
TenarisHydril

9
Torque Application
TenarisHydril Blue® Near Flush Connection

1. The use of computer make up analysis equipment


is strongly recommended when assembling Blue® Near
Flush connections.

2. Shoulder points for Blue® Near Flush connections.

.Minimum 10% of optimum.


.Maximum 85% of optimum.
.A shoulder point above 85% can be accepted but
should never exceed 90% of optimum torque,
CONNECTION SPECIFIC RUNNING GUIDELINES

additionally the graph must also display a minimum


delta torque of 5% of optimum.

.Delta torque % = (final torque – shoulder torque) x


100 ÷ optimum torque.

3. Reference torque should initially be set at 5% of


optimum torque.

4. The dump valve should be set at optimum, verify


correct operation on the pipe body prior to first make up.

5. Set the computer turns to 2 initially then adjust as


necessary to attain good graph depiction.

6. Refer to the TenarisHydril Running Manual make up


acceptance section for further explanation.
RUNNING MANUAL

7. TenarisHydril Blue® Near Flush connections of the


same diameter are not interchangeable with different
weights.

8. If different weight or grade of connections are to be


mixed apply the lower weight or grade make up torque.
TenarisHydril

10
9. When assembling Dopeless® Technology connections

TenarisHydril Blue® Near Flush Connection


the torques applied must be taken from the Dopeless®
Technology variant product data sheet.

10. When mixing standard doped and Dopeless®


Technology connections apply the torque values
indicated in the table below.

TORQUE
APPLICATION DOPELESS® PIN STANDARD PIN

Standard Apply the higher torque


Box value of Standard / Doped Torques
Dopeless®

Dopeless® Apply the lower torque


Box Dopeless® Torques value of Standard /

CONNECTION SPECIFIC RUNNING GUIDELINES


Dopeless®
IDM Code GDL00273/5 / March 2022

11. The computer make up profile for Blue® Near Flush


connections should be similar to the ones below.

MAX. 6710
6.7
OPT 6100
MAX. SHL 5185 MIN. 5490
TORQUE * 1000 ft-lbs

5.0

3.4

1.7
MIN. SHL 610

0
0 0.23 0.45 0.68 0.91 TURNS
RUNNING MANUAL
TenarisHydril

11
TenarisHydril Blue® Near Flush Connection

MAX. 18220
17.5 OPT 16560
MIN. 14900
MAX. SHL 14076
TORQUE * 1000 ft-lbs

13.1

8.8

4.4
MIN. SHL 1656

0
0 0.25 0.50 0.74 0.99 TURNS

Running
CONNECTION SPECIFIC RUNNING GUIDELINES

1. The use of a stabbing guide is strongly


recommended.

2. Slip type elevators are recommended.

3. The use of a safety clamp is strongly recommended


when running Blue® Near flush connections.

4. The use of a weight compensator is strongly


recommended for chrome, large OD and heavy pipe.

5. To avoid cross threading stab pipe in a smooth


controlled fashion ensuring the pipe is vertical
when doing so, continue to support and stabilise
the pipe throughout the stabbing and make up
operation.
RUNNING MANUAL

6. Ensure the back up tong is located below the box


upset to prevent damage.

7. Upon commencement of initial rotation use low


RPM (5 RPM or below) in order to ensure the pipe has
TenarisHydril

not cross threaded during stabbing.

12
8. If cross threading is evident, immediately reverse

TenarisHydril Blue® Near Flush Connection


rotate the pipe, completely disassemble, clean and
inspect both connections.

9. Maximum spin in speed should not exceed 15 RPM.

10. Apply power at low RPM (do not exceed 5 RPM)


for final make up.

11. Walk chrome pipe all the way in to hand tight,


then apply tong only for final make up.

Pulling

CONNECTION SPECIFIC RUNNING GUIDELINES


1. Automatic stabbing system or stabber is highly
recommended to stabilise the pipe vertically.
IDM Code GDL00273/5 / March 2022

2. The use of a stabbing guide is recommended to


assist in centralizing the pin to prevent hang up.

3. The use of a safety clamp is strongly recommended.

4. A weight compensator is strongly recommended for


chrome, large OD and heavy weight pipe.

5. Apply the back up tong on the pipe body below the


expanded area.

6. Apply power tong in low RPM (3-5 RPM) to break


the connection, ensuring the pipe is stabilised during
the break and spin out process.
RUNNING MANUAL

7. Do not exceed 15 RPM during spin out.

8. Walk chrome pipe all the way out by hand after


initial break.
TenarisHydril

9. Visual inspection is recommended to classify the


thread condition, any rejected connections should be
clearly marked and segregated for further investigation.
13
10. Apply clean, dry thread protectors after applying
TenarisHydril Blue® Near Flush Connection

storage compound on clean, dry connections.

11. Storage / thread compound should always be


applied to connections post job, even rejects.

12. Do not apply storage compound to Dopeless®


Technology connections.

13. For long term storage of Dopeless® Technology


connections, refurbishment by qualified personnel is
recommended.

14. Ensure clean, dry, Dopeless® Technology protectors


CONNECTION SPECIFIC RUNNING GUIDELINES

with seal rings correctly in place are installed.


RUNNING MANUAL

Tenaris has produced this manual for general information only. While every effort has been made to
ensure the accuracy of the information contained within this publication, Tenaris does not assume any
TenarisHydril

responsibility or liability for any loss, damage, injury resulting from the use of information and data
herein. Tenaris products and services are only subject to the Company’s standard terms and Conditions
or otherwise to the terms resulting from the respective contracts of sale, services or license, as the case
may be. The information in this publication is subject to change or modification without notice. For more
complete information please contact a Tenaris’s representative or visit our website at www.tenaris.com.
©Tenaris 2022. All rights reserved.

14

You might also like