Professional Documents
Culture Documents
Scope
These guidelines apply specifically to the use of
References
.TenarisHydril Running Manual.
.Premium Connection Approved Thread Compounds
.TSH-MD-00.0002.
Recommended guidelines for the field inspection of
TenarisHydril connections, FSOG 13-005.
1
Pre-Running
TenarisHydril 3SB™ Connection
.TenarisHydril 3SB™ / A
.TenarisHydril 3SB ST™
.NK3SB / TS3SB
RUNNING MANUAL
2
Inspection
RUNNING MANUAL
TenarisHydril
3
4
TenarisHydril RUNNING MANUAL Connection Specific Running Guidelines TenarisHydril 3SB™ Connection
SEAL
torque
shoulder
Tubing 8 TPI ≤ 4 ½" 13.5#
Casing 5 TPI ≥ 4 ½" 13.5#
3SB™ Configuration
Thread Compound Application
5
Thread Lock Application
TenarisHydril 3SB™ Connection
Connection Specific Running Guidelines
6
Torque Application
.Minimum 5% of optimum.
.Maximum 80% of optimum.
7
TenarisHydril 3SB™ Connection
MAX. 7040
6.8
OPT 6400
MAX. SHL 5120 MIN. 5120
TORQUE * 1000 ft-lbs
5.1
3.4
1.7
MIN. SHL 320
0
0 0.16 0.32 0.48 0.65 TURNS
Connection Specific Running Guidelines
MAX. 7040
6.8
OPT 6400
MAX. SHL 5120 MIN. 5120
TORQUE * 1000 ft-lbs
5.1
3.4
1.7
MIN. SHL 320
0
0 0.23 0.47 0.70 0.93 TURNS
8
Running
9
Pulling
TenarisHydril 3SB™ Connection
7. Walk chrome pipe all the way out after initial break.
10