Professional Documents
Culture Documents
KATHREIN SE
Anton-Kathrein-Straße 1–3
83022 Rosenheim
Rosenheim, 01.05.2018
Germany
Phone: +49 8031 184-0
Fax: +49 8031 184-306
KATHREIN-Werke KG ist jetzt KATHREIN SE www.kathrein.com
KATHREIN-Werke KG is now KATHREIN SE
Executive Board:
Zum 1. Mai 2018 ist die KATHREIN-Werke KG auf die KATHREIN SE, Anton Kathrein (CEO),
einer Europäischen Aktiengesellschaft (Societas Europaea), Joachim Döring, Elmar Geißinger,
übergegangen. Jürgen Walter, Hans-Joachim Ziems
Supervisory Board:
Die neuen Firmendaten lauten seither wie folgt: Dr. Michael F. Keppel (Chairman)
KATHREIN SE
Anton-Kathrein-Str. 1–3
83022 Rosenheim, Deutschland VAT Reg. No.: DE 131 558 540
Steuer-Nr.: 156/117/30745 Tax ID No.: 156/117/30745
UST-Ident-Nr.: DE 131 558 540 WEEE Reg. No.: DE 38438502
GLN: 40 21121 00000 3
Registergericht: Traunstein, HRB 24848
Registered Office: Rosenheim, DE
Commercial Register: Traunstein, HRB 24848
______________________________________________________________________________
Deutsche Bank AG
IBAN: DE54 7007 0010 0833 7701 00
BIC: DEUTDEMMXXX
On 1st May 2018, KATHREIN-Werke KG has been transferred
to KATHREIN SE, a European stock corporation (Societas Europaea).
Page 1 of 1
2-Port Antenna B1
Frequency Range 1710–2170
Dual Polarization X
HPBW 30°
Adjust. Electr. DT 0°–8°
set by hand or by optional RCU (Remote Control Unit)
Mechanical specifications
9 | 0.4
2) 2) 64 | 2.5
Remarks Weight approx. Units per
Type No. Description
mm | inches kg | lb antenna
1304 | 51.3
1381 | 54.4
1421 | 56.0
1526 | 60.1
All screws and nuts: Stainless steel.
Grounding: The metal parts of the antenna including the mounting kit and the inner
conductors are DC grounded.
Correlation Table
Frequency range Array Connector
B1 Adjustment
mechanism
with integrated
scale
All dimensions in mm | inches
Layout of interface:
40 | 1.6
83 | 3.3
69 | 2.7
Subject to alteration.
–45° +45°
299 | 11.7
936.4893/b
Bottom view
All dimensions in mm | inches
Page 2 of 2 742351V01 Any previous data sheet issues have now become invalid.
www.kathrein.com
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
Mounting Hardware
Clamp Included in the Scope of Supply
152 [5.98]
100 [3.94]
[0.79–0.98]
40 [1.57]
72 [2.83]
20–25
40 [1.57]
15
2–1
4 4.53]
5–
[1.6
M10 MA = 25 Nm
M8 MA = 20 Nm
35 [1.38]
64 [2.52]
125 [4.92]
20–25
[0.79–0.98]
Subject to alteration.
936.3920/c
Please note: Kathrein does not recommend to use counter nuts. All dimensions in mm and [inches]
The additional nuts supplied are only meant as spares.
Any previous data sheet issues have now become invalid. 738546 Page 1 of 1
www.kathrein.de
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
Mounting Hardware
Clamp Included in the Scope of Supply
152 | 5.98
100 | 3.94
40 | 1.57
0.79–0.98
72 | 2.8
20–25
40 | 1.57
15
2–1
4 4.53
–
1.65
M10 MA = 25 Nm
M8 MA = 12 Nm
35 | 1.38
64 | 2.52
125 | 4.92
20–25
0.79–0.98
936.3920d | Subject to alteration.
Please note: Kathrein does not recommend to use counter nuts. All dimensions in mm | inches
The additional nuts supplied are only meant as spares.
Any previous data sheet issues have now become invalid. 738546 Page 1 of 1
KATHREIN-Werke KG | Anton-Kathrein-Straße 1– 3 | 83022 Rosenheim, Germany | Phone +49 8031 184-0 | www.kathrein.com | mobilcom@kathrein.de
General Instructions
for Adjustment Mechanism
1
2
2
➀ Twist protection. ➀ Thread for fixing the protective To set the downtilt angle exactly,
➁ Downtilt spindle with integrated cap or the RCU (Remote Control you must look horizontally at the
scale. Unit). scale. The lower edge of the gear-
➁ Gearwheel for RCU power drive. wheel must be used for alignment.
0° – max.°
0° – max.°
Remove the protective cap and the Set downtilt angle by rotating the Screw on the twist protection and
twist protection completely. gearwheel. the protective cap again.
For a description of RCU installation please refer to the respective data sheet.
www.kathrein.com Page 1 of 2
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
General Instructions
for Feederline and RCU Installation
for Antennas
Please note: In order not to damage the interfaces, please make sure that only the right tools are used.
Tighten the feederline connector interfaces solely by using a common torque-wrench with a suitable wrench
width.
Adjustment mechanism
(protective cap removed) Ventilation hole
Colour coding:
Correlation of each RF input to:
– the corresponding adjustment mechanism
7-16 female (long neck) – the frequency range
– the polarization
32 | 1.3
Subject to alteration.
guidelines). 41
| 1.
1
These tools are suitable for 7-16 connectors with a wrench size of
27 or 32 mm | 1.1 or 1.3 inches, and the RCU attachment nut with a
wrench size of 41 mm | 1.6 inches.
Tighten nuts within a torque range of 25 – 33 Nm depending on
connector manufacturers’ specifications, respectively the RCU nut
with a torque range of 15 – 18 Nm.
Page 2 of 2 Any previous data sheet issues have now become invalid.
www.kathrein.com
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820
General Information
about Panel Antennas
Environmental Kathrein cellular antennas are designed to operate under the environmental conditions
conditions: as described in ETS 300 019-1-4 class 4.1 E.
The antennas exceed this standard with regard to the following items:
– Low temperature: –55 °C
– High temperature (dry): +60 °C
For antennas equipped with FlexRET: The electrical downtilt adjusting is designed to
operate under the environmental conditions as described in the valid data sheet of the
FlexRET.
Ice protection: Due to the very sturdy antenna construction and the protection of
the radiating system by the radome, the antenna remains operational even under icy
conditions.
Environmental Kathrein antennas fulfil the stated specifications after completion of the environmental
tests: tests as defined in ETS 300 019-2-4. The homogenous d esign of Kathrein’s antenna
families uses identical modules and materials.
Extensive tests have been performed on typical samples and modules. The vibration
test has been adapted relating to frequency and acceleration to the conditions of mast
mounted antennas.
Please note: As a result of more stringent legal regulations and judgements regarding product
liability, we are obliged to point out certain risks that may arise when products are
used under extraordinary operating conditions.
The details given in our data sheets have to be f ollowed carefully when installing
the antennas and a ccessories.
Site planning and installation must be carried out by qualified and experienced
staff. All relevant national safety regulations must be upheld and respected.
Incorrect site planning, faulty installation, as well as interfering surroundings
on site, may lead to deviations in the electrical parameters compared to those
specified in the respective data sheets.
The connectors on this product are only suitable for connecting to the compatible
counterpart. Please ensure that the connected cable has been fitted with a
connector of the same standard, otherwise damage may occur.
The tilt values will be set to any arbitrary value in the given tilt range. These values
Subject to alteration.
are independent from the frequency band or antenna type and can vary between
antennas and bands.
EU-RED Hereby, Kathrein Werke KG declares that the radio equipment is in compliance with
Directive 2014/53/EU. The full text of the EU declaration of conformity is available at
the following internet address: http://www.kathrein.com
936.4694/d
Our quality assurance system and our RoHS Our products are compliant to the
environmental management system apply EU Directive RoHS as well as to other
to the entire company and are certified environmentally relevant regulations
by TÜV according to EN ISO 9001 and (e.g. REACH).
EN ISO 14001.
Any previous data sheet issues have now become invalid. Page 1 of 1
www.kathrein.com
KATHREIN-Werke KG · Anton-Kathrein-Straße 1-3 · P.O. Box 10 04 44 · 83004 ROSENHEIM · GERMANY · Phone +49 8031 184-0 · Fax +49 8031 184-820