Product description Important instructions for assembly and Synchronisation mode.

mbly and Synchronisation mode. (To use synchronised mode all sensors  Measurement range set to maximum ran-
 The mic+sensor with two switched out- application If the assembly distances shown in Fig.1 for must be set to address »00«.) ge
puts measures the distance to an object All employee and plant safety-relevant two or more sensors are exceeded the inte-
Ultrasonic Sensors within the detection zone contactless. De- measures must be taken prior to assembly, grated synchronisation should be used. Con- Assembly instructions Set the parameters of the sensor manually or
pending on the adjusted detect distance start-up, or maintenance work (see operation nect Sync/Com-channels (pin 5 at the units re-  Assemble the sensor at the installation lo- use the Teach-in procedure to adjust the de-
the switched outputs are set. manual for the entire plant and the operator ceptable) of all sensors (10 maximum). cation. tect points.
 All settings are done with two push-but- instruction of the plant).  Plug in the connector cable to the M 12
tons and a three-digit LED-display A B connector.
(TouchControl). The sensors are not considered as safety measuring range
equipment and may not be used to ensure cm mm %
 Light emitting diodes (three-colour LEDs) ≤ 0,35 m ≤ 2,50 m 3-digit
indicate the switching status. human or machine safety! ≤ 0,40 m ≤ 2,50 m 2 1 LED-display
 The output functions are changeable ≤ 1,10 m ≤8,00 m 3 5 4
The mic+ sensors indicate a blind zone, in LED D1 and D2
from NOC to NCC. ≤ 2,00 m ≤ 18,00 m colour
which the distance cannot be measured. The
 The sensors are adjustable manually using ≤ 4,00 m ≤ 30,00 m 1 +UB brown
operating range indicates the distance of the Push-buttons T1 and T2
the numerical LED-display or may be trai- 3 -UB blue T1 D1 D2 T2
sensor that can be applied with normal re-
ned using Teach-in processes. 4 D2 black
flectors with sufficient function reserve. 2 D1 white
 Useful additional functions are set in the When using good reflectors, such as a calm Fig. 1: Assembly distances, indicating syn- 5 Sync/Com. grey
Add-on-menu. water surface, the sensor can also be used up chronisation/multiplex Fig. 3: TouchControl
 Using the LinkControl adapter (optional to its maximum range. Objects that strongly
Instruction manual accessory) all TouchControl and additio- absorb (e.g. plastic foam) or diffusely reflect Multiplex mode Fig. 2: Pin assignment with view onto sensor Operation
mic+ Ultrasonic Sensors with nal sensor parameter settings may be sound (e.g. pebble stones) can also reduce The Add-on-menu allows to assign an indivi- plug and colour coding of the mic+sensors work maintenance free. Small
two switched outputs made by a Windows-Software. the defined operating range. dual address »01« to »10« to each sensor microsonic connection cable amounts of dirt on the surface do not influ-
connected via the Sync/Com-channel (Pin5). ence function. Thick layers of dirt and caked-
The sensors perform the ultrasonic measure- Start-up on dirt affect sensor function and therefore
mic+25/DD/TC mic+25/EE/TC ment sequentially from low to high address. mic+ sensors are delivered factory made with must be removed.
mic+35/DD/TC mic+35/EE/TC Therefore any influence between the sensors the following settings:
mic+130/DD/TC mic+130/EE/TC is rejected.  Switched outputs on NOC Note
The address »00« is reserved to synchronisa-  Detecting distances at operating range
mic+340/DD/TC mic+340EE/TC tion mode and deactivates the multiplex and half operating range  mic+sensors have internal temperature
mic+600/DD/TC mic+600/EE/TC compensation. Because the sensors heat
up on their own, the temperature com-
Set sensor parameters alternatively numerically using LED-display... pensation reaches its optimum working
point after approx. 30 minutes of operati-
Start here on.

T1 + T2
  During normal mode operation, a yellow
LED signals that the corresponding
Press T1 and T2 simultaneously for about switched output has connected.
3 s until welcome message has passed
 During normal mode operation, the mea-
sured distance value is displayed on the
LED-indicator in mm (up to 999 mm) or
 T1 T2   T1 T2  cm (from 100 cm). Scale switches auto-
matically and is indicated by a point on
T1 + T2 T1 + T2 top of the digits.
 
 Set detect distance in  Set detect distance in
 During Teach-in mode, the hysteresis
T1 T2 T1 T2 mm or cm loops are set back to factory settings.
mm or cm
 
T1 + T2 T1 + T2  If no objects are placed within the detec-
  tion zone the LED-indicator shows »- - -«.

 For single detect


point press T2  For window mode
operation set far  For single detect
point press T2 T2 For window mode
operation set far
 If no push-buttons are pressed for 20 se-
T2 until »- - -« is T1 T2 detect point in T2 until »- - -« is T1 conds during parameter setting mode the
detect point in
displayed  mm or cm displayed  mm or cm made changes are stored and the sensor
returns to normal mode operation.
T1 + T2 T1 + T2
   You can lock the key pad to provide in-
 Choose » « for NCC or
 Choose » « for NCC
puts, see »Key lock and factory setting«.
T1 T2 T1 T2
» « for NOC or » « for NOC
   You can reset the factory settings at any
T1 + T2 T1 + T2 time, see »Key lock and factory setting«.
 
Show parameters
Set switched output D1 Set switched output D2
Tapping push-button T1 shortly during nor-
mal mode operation shows »PAr« on the
 T2 T1  LED-display. Each time you tap push-button
T1 the actual settings of the switched out-
puts are shown.
T1 + T2

Ready
2004/108/EC
...or with the Teach-in procedure Key lock and factory setting

Activate/deactivate Reset to factory set-


TouchControl ting

Turn supply voltage Turn supply voltage


OFF OFF
Adjust two-way reflectiv Adjust two-way reflectiv
Adjust detect point D1 Adjust window mode D1 Set NOC/NCC D1 Adjust detect point D2 Adjust window mode D2 Set NOC/NCC D2
barrier D1 barrier D2

Turn supply voltage


Place object at position  Place object at position  Place reflector at position  Place object at position  Place object at position  Place reflector at position  While pressing T1 ON while pressing T1
turn supply voltage and keep it pressed
ON until »on« or for ca. 15 s until
»off« is displayed »rESEt« has passed
Press T1 until countdown Press T2 until countdown through the display
passed from »- 8 -« to »- 0 -« passed from »- 8 -« to »- 0 -«
Press T1 until »d1« is shown Press T1 until »d1« is shown Press T1 until »d1« is shown Press T2 until »d2« is shown Press T2 until »d2« is shown Press T2 until »d2« is shown
and NOC or NCC symbol is and NOC or NCC symbol is »on« or
displayed displayed »off«

Current measu- Current measu- Current measu- Symbol Current measu- Current measu- Current measu- Symbol To activate or
ring value ring value ring value NOC or NCC ring value ring value ring value NOC or NCC deactivate press T1

Place object at position  Place object at position  »on« or


»off«

Current measu- Current measu- To activate or


ring value ring value
deactivate press T1
Press T1 until countdown Press T2 until countdown
Press T1 until »End« is Press T1 until »End« is To change output function Press T2 until »End« is Press T2 until »End« is To change output function
passed from »- 8 -« to »- 0 -« passed from »- 8 -« to »- 0 -«
shown shown press T1 shown shown press T2
and »End« is displayed and »End« is displayed

Symbol Symbol
NOC or NCC NOC or NCC

Press T1 and T2 simultaneously Press T1 and T2 simultaneously


until »End« is displayed until »End« is displayed

Normal mode operation Normal mode operation

Normal mode operation


Teach-in switched output D1 Teach-in switched output D2

Usefull additional functions in Add-on menu (for experienced users only, settings not required for standard applications)

Start here
T1 + T2

Press T1 and T2 simultaneously for about 13 s
until »Add« is shown in the LED-display

T1 T2 T1  T1


T2 T2 T1  T1
T2 T2  T1 T2  T1 T2 T1  T1
T2 T2 T1 T2 T1  T1
T2 T2 
T1 + T2 T1 + T2 T1 + T2 T1 + T2 T1 + T2 T1 + T2 T1 + T2 T1 + T2 T1 + T2 T1 + T2 T1 + T2 T1 + T2

                       
T1 T2 T1 T2 T1 T2 T1 T2 T1 T2 T1 T2 T1 T2 T1 T2 T1 T2 T1 T2 T1 T2 T1 T2
 T1 + T2  T1 + T2  T1 + T2  T1 + T2  T1 + T2  T1 + T2  T1 + T2  T1 + T2  T1 + T2  T1 + T2  T1 + T2  T1 + T2
           

T2 
T1

T1 + T2
 »C01«: Display
bright
Minimum value:
»001«
Minimum value:
»001«
»F00«: no filter Defines the strength
of the chosen filter.
Delay in seconds
between the detec-
Minimum value:
blind zone
»00«: synchronisati-
on
To optimize multi-
plex speed the hig-
Minimum value: sen-
sor-distant window
Put plane reflector
vertically disposed in
Affects the size of
the detection zone.
»F01«: standard fil-
Ready »C02«: Display dim- Maximum value: dif- Maximum value: dif- ter »P00«: weak filter
tion of an object
and the output of
Maximum value: ne- »01« to »10«: sensor
hest sensor address
may be set.
margin front of sensor: in
an exact distance of
»E01«: high
med ference between ference between up to arwindow limit - 1 address for multi- Maximum value: 999
»F02«: averaging fil- the measured dis- 250 mm for mic+ »E02«: standard
maximum range and maximum range and plex mode Setting range »01« mm for mic+
»C03«: Display off ter »P09«: strong filter tance in case of ob- 25... and mic+35...
detect point - 1 detect point - 1 to »10« 25/...,mic+35/..., »E03«: slight
ject approach (beha- »oFF«: synchronisati- and 900 mm for all
»F03«: foreground 999 cm for mic+
During window During window ves as on-delay). on deactivated other typs.
filter 130/...,mic+340/...,
mode operation hys- mode operation hys- Adjust display to
"00": 0 s (no delay) mic+600/...
teresis influences teresis influences »F04«: background 250 mm or 900 mm.
up to
Note both detect points. both detect points. filter Confirm calibration
Changes in the Add-on "20": 20 s response with T1 + T2.
menu may impair the time
sensor function.
A6, A7, A8 , A10 , A11,
A12 have influence on
the response time of
the sensor.
Low power mode Hysteresis Hysteresis Measurement filter Filter strength Response time Foreground Multiplex mode Multiplex mode Measurement range Calibration Detection zone
switched output D1 switched output D2 suppression device addressing highest address display sensitivity
Technical data
1 +UB
U
2 D1 mic+25… mic+35… mic+130… mic+340… mic+600…
4 D2
5 Sync/Com
3 -UB
2 pnp switched outputs

1 +UB
U
2 E1
4 E2
5 Sync/Com
3 -UB
2 npn switched outputs

Blind zone 0 to 30 mm 0 to 60 mm 0 to 200 mm 0 to 350 mm 0 to 600 mm


Operating range 250 mm 350 mm 1.300 mm 3.400 mm 6.000 mm
Maximum range 350 mm 600 mm 2.000 mm 5.000 mm 8.000 mm
Angle of beam spread Please see detection zone Please see detection zone Please see detection zone Please see detection zone Please see detection zone
Transducer frequency ca. 320 kHz ca. 400 kHz ca. 200 kHz ca. 120 kHz ca. 80 kHz
Resolution, sampling rate 0,025 mm 0,025 mm 0,18 mm 0,18 mm 0,18 mm
Reproducibility ± 0,15 % ± 0,15 % ± 0,15 % ± 0,15 % ± 0,15 %
Accuracy ± 1 % (Temperature drift internal compensated, ± 1 % (Temperature drift internal compensated, ± 1 % (Temperature drift internal compensated, ± 1 % (Temperature drift internal compensated, ± 1 % (Temperature drift internal compensated,
may be deactivated1), 0,17%/K without compensation) may be deactivated1), 0,17%/K without compensation) may be deactivated1), 0,17%/K without compensation) may be deactivated1), 0,17%/K without compensation) may be deactivated1), 0,17%/K without compensation)
Detection zones

20 cm

10 cm

10 cm

20 cm
10 cm

10 cm

1,6 m

0,8 m

0,8 m

1,6 m

2,4 m

1,2 m

1,2 m

2,4 m
0,8 m

0,4 m

0,4 m

0,8 m
0 cm
5 cm

0 cm

5 cm

0m

0m
0m
for different objects:
The dark grey areas are determind 0 cm 0 cm 0m 0m 0m
with a thin round bar (10 or 27 mm dia.)
and indicate the typical operating range
of a sensor. In order to obtain the light grey
areas, a plate (500 x 500 mm) is introduced 5 cm 10 cm 0,8 m 1,2 m
into the beam spread from the side. Plate Plate 0,4 m Plate Plate
In doing so, the optimum angle between Plate
plate and sensor is always employed.
10 cm 1,6 m 2,4 m
This therefore indicates the maximum 20 cm Round bar
Round bar Round bar
detection zone of the sensor. Round bar
0,8 m
It is not possible to evaluate ultrasonic Round bar
reflections outside this area. 15 cm 2,4 m 3,6 m
30 cm

35 cm 1,2 m
20 cm 1,3 m 3,2 m 4,8 m
40 cm 3,4 m

25 cm 1,6 m 4m 6m
50 cm

30 cm 4,8 m 7,2 m
60 cm 2m

35 cm 5,6 m 8,4 m

Opperating voltage UB 9 V to 30 V DC, reverse polarity protection 9 V to 30 V DC, reverse polarity protection 9 V to 30 V DC, reverse polarity protection 9 V to 30 V DC, reverse polarity protection 9 V to 30 V DC, reverse polarity protection
Voltage ripple ±10 % ±10 % ±10 % ±10 % ±10 %
No-load supply current ≤ 80 mA ≤ 80 mA ≤ 80 mA ≤ 80 mA ≤ 80 mA
Housing Brass sleeve, nickel-plated, plastic parts: PBT, TPU; Brass sleeve, nickel-plated, plastic parts: PBT, TPU; Brass sleeve, nickel-plated, plastic parts: PBT, TPU; Brass sleeve, nickel-plated, plastic parts: PBT, TPU; Brass sleeve, nickel-plated, plastic parts: PBT, TPU;
Ultrasonic transducer: polyurethane foam, Ultrasonic transducer: polyurethane foam, Ultrasonic transducer: polyurethane foam, Ultrasonic transducer: polyurethane foam, Ultrasonic transducer: polyurethane foam,
epoxy resin with glass content epoxy resin with glass content epoxy resin with glass content epoxy resin with glass content epoxy resin with glass content
Class of protection to EN 60529 IP 67 IP 67 IP 67 IP 67 IP 67
Norm conformity EN 60947-5-2 EN 60947-5-2 EN 60947-5-2 EN 60947-5-2 EN 60947-5-2
Type of connection 5-pin initiator plug, PBT 5-pin initiator plug, PBT 5-pin initiator plug, PBT 5-pin initiator plug, PBT 5-pin initiator plug, PBT
Controls 2 push-buttons (TouchControl) 2 push-buttons (TouchControl) 2 push-buttons (TouchControl) 2 push-buttons (TouchControl) 2 push-buttons (TouchControl)
Indicators 3-digit LED-display, 2 three-colour LEDs 3-digit LED-display, 2 three-colour LEDs 3-digit LED-display, 2 three-colour LEDs 3-digit LED-display, 2 three-colour LEDs 3-digit LED-display, 2 three-colour LEDs
Programmable Yes, with TouchControl and LinkControl Yes, with TouchControl and LinkControl Yes, with TouchControl and LinkControl Yes, with TouchControl and LinkControl Yes, with TouchControl and LinkControl
Operating temperature -25°C to +70°C -25°C bis +70°C -25°C bis +70°C -25°C bis +70°C -25°C bis +70°C
Storage temperature -40°C to +85°C -40°C bis +85°C -40°C bis +85°C -40°C bis +85°C -40°C bis +85°C
Weight 150 g 150 g 150 g 210 g 270 g
Switching hysteresis1) 3 mm 5 mm 20 mm 50 mm 100 mm
switching frequency1) 25 Hz 12 Hz 8 Hz 4 Hz 3 Hz
Response time1) 32 ms 64 ms 92 ms 172 ms 240 ms
Time delay before availibility < 300 ms < 300 ms < 300 ms < 300 ms < 300 ms

Order No. mic+25/DD/TC mic+35/DD/TC mic+130/DD/TC mic+340/DD/TC mic+600/DD/TC


Switched output 2 x pnp, UB - 2 V, Imax = 2 x 200 mA 2 x pnp, UB - 2 V, Imax = 2 x 200 mA 2 x pnp, UB - 2 V, Imax = 2 x 200 mA 2 x pnp, UB - 2 V, Imax = 2 x 200 mA 2 x pnp, UB - 2 V, Imax = 2 x 200 mA
switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof

Order No.mic+25/EE/TC mic+35/EE/TC mic+130/EE/TC mic+340/EE/TC mic+600/EE/TC


Switched output2 x npn, -UB + 2 V, Imax = 2 x 200 mA 2 x npn, -UB + 2 V, Imax = 2 x 200 mA 2 x npn, -UB + 2 V, Imax = 2 x 200 mA 2 x npn, -UB + 2 V, Imax = 2 x 200 mA 2 x npn, -UB + 2 V, Imax = 2 x 200 mA
switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof switchable NOC/NCC, short-circuit-proof
1) Can be programmed with TouchControl and LinkControl

*5396*
MV-DO-041943-368706 The contents of this document are subject to technical changes. Specifications are presented in a descripted way only. They do not warrant product features. microsonic GmbH I Hauert 16 I D-44227 Dortmund I Tel: +49 (0)2 31 / 97 51 51-0 I Fax: +49 (0)2 31 / 97 51 51-51 I E-Mail: info@microsonic.de I www.microsonic.de